5680

English

EN

Operator Manual

www.tennantco.com

Home Find... Go To..

330459

Rev. 10 (10-2008)

*330459*

This manual is furnished with each new model. It provides necessary operation and maintenance instructions.

Read this manual completely and understand the machine before operating or servicing it.

This machine will provide excellent service. However, the best results will be obtained at minimum costs if:

S

The machine is operated with reasonable care.

S

The machine is maintained regularly - per the machine maintenance instructions provided.

S

The machine is maintained with manufacturer supplied or equivalent parts.

PROTECT THE ENVIRONMENT

Please dispose of packaging materials, old machine components such as batteries, hazardous fluids such as antifreeze and oil, in an environmentally safe way according to local waste disposal regulations.

Always remember to recycle.

MACHINE DATA

Please fill out at time of installation for future reference.

Model No. --

Serial No. --

Machine Options --

Sales Rep. --

Sales Rep. phone no. --

Customer Number --

Installation Date --

TENNANT N.V.

Industrielaan 6 5405 AB

P.O. Box 6 5400 AA Uden--The Netherlands

[email protected]

www.tennantco.com

Specifications and parts are subject to change without notice.

Original instructions, copyright E2000, 2002, 2004--2006, 2008 Tennant Company, Printed in The Netherlands

All rights reserved.

Home Find... Go To..

CONTENTS

CONTENTS

SAFETY PRECAUTIONS

Page

. . . . . . . . . . . . . . . . .

3

OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .

OPERATOR RESPONSIBILITY . . . . . . . .

MACHINE COMPONENTS . . . . . . . . . . . .

CONTROL PANEL SYMBOLS . . . . . . . . .

CONTROLS AND INSTRUMENTS . . . . . .

STEERING HANDLES

ON-OFF KEY SWITCH

. . . . . . . . . . . . .

. . . . . . . . . . . .

SCRUB SWITCH . . . . . . . . . . . . . . . . .

11

SCRUB HEAD STRAP (DISC HEAD) 11

SQUEEGEE LEVER

HOURMETER

. . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . .

11

12

9

10

7

8

5

5

6

BATTERY DISCHARGE INDICATOR 12

FaST SWITCH (OPTION) . . . . . . . . . .

12

ec--H2O SWITCH (OPTION)

POWER KILL SWITCH

. . . . . . .

. . . . . . . . . . . .

13

13

SOLUTION FLOW LEVER

CIRCUIT BREAKERS

SUPPORT ARM

. . . . . . . . .

. . . . . . . . . . . . .

SOLUTION TANK HOSE . . . . . . . . . . .

RECOVERY TANK DRAIN HOSE . . .

. . . . . . . . . . . . . . . . . .

STOP ARM . . . . . . . . . . . . . . . . . . . . . .

SQUEEGEE DOWN PRESSURE

CAMS . . . . . . . . . . . . . . . . . . . . . . . . .

PARKING BRAKE . . . . . . . . . . . . . . . . .

14

14

15

15

15

16

16

16

17 HOW THE MACHINE WORKS . . . . . . . . .

FaST SCRUBBING SYSTEM

(OPTION) . . . . . . . . . . . . . . . . . . . . . .

ec--H2O SYSTEM (OPTION) . . . . . . .

PRE-OPERATION CHECKLIST . . . . . . . .

INSTALLING FaST PAK AGENT

(OPTION) . . . . . . . . . . . . . . . . . . . . . . .

STARTING THE MACHINE

FILLING THE TANKS

. . . . . . . . . . . .

. . . . . . . . . . . . . . . . .

18

19

20

21

23

23

SCRUBBING AND BRUSH

INFORMATION . . . . . . . . . . . . . . . . . . . . .

DOUBLE SCRUBBING . . . . . . . . . . . . . . . .

STOP SCRUBBING . . . . . . . . . . . . . . . . . . .

DRAINING AND CLEANING

THE TANKS . . . . . . . . . . . . . . . . . . . . . . . .

OPERATION ON INCLINES

STOP THE MACHINE

. . . . . . . . . . .

. . . . . . . . . . . . . . . . .

POST-OPERATION CHECKLIST

MACHINE TROUBLESHOOTING

. . . . . . .

. . . . . . .

25

29

30

31

35

35

36

37

MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE CHART . . . . . . . . . . . . . . .

LUBRICATION . . . . . . . . . . . . . . . . . . . . . . .

REAR CASTERS

TRANSAXLE

. . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . .

BATTERIES . . . . . . . . . . . . . . . . . . . . . . . . .

CHARGING THE BATTERIES . . . . . .

ELECTRIC MOTORS . . . . . . . . . . . . . . . . .

39

39

41

41

41

41

43

44

5680 330459 (10--08)

SCRUB HEAD

Page

. . . . . . . . . . . . . . . . . . . . . . .

45

DISK BRUSH SCRUB HEAD SKIRT .

45

CYLINDRICAL BRUSH SCRUB

HEAD SKIRTS . . . . . . . . . . . . . . . . . .

ADJUSTING THE SCRUB

45

45 HEAD SKIRTS . . . . . . . . . . . . . . . . . .

REPLACING THE SCRUB

HEAD SKIRTS . . . . . . . . . . . . . . . . . .

REMOVING OR REPLACING

THE SCRUB HEAD . . . . . . . . . . . . . .

LEVELING THE SCRUB HEAD . . . . .

SCRUB BRUSHES AND PADS . . . . . . . . .

45

46

49

50

50 DISK BRUSHES . . . . . . . . . . . . . . . . . .

REPLACING THE DISK BRUSHES

OR PADS . . . . . . . . . . . . . . . . . . . . . .

CYLINDRICAL BRUSHES . . . . . . . . . .

REPLACING THE CYLINDRICAL

BRUSHES . . . . . . . . . . . . . . . . . . . . . .

CHECKING AND ADJUSTING

CYLINDRICAL BRUSH PATTERN

SOLUTION SYSTEM

. . . . . .

. . . . . . . . . . . . . . . . .

50

54

54

RECOVERY TANK

SOLUTION TANK

. . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . .

FaST SYSTEM (OPTION)

FaST SUPPLY HOSE

. . . . . . . . . . . . .

FaST SYSTEM MAINTENANCE

FaST SYSTEM FILTER SCREEN

. . . .

. . .

CONNECTOR . . . . . . . . . . . . . . . . . .

ec--H2O SYSTEM (OPTION) . . . . . . . . . . .

ec--H2O MODULE FLUSH

PROCEDURE . . . . . . . . . . . . . . . . . .

59

59

60

55

57

57

58

60

61

61

62 SQUEEGEE . . . . . . . . . . . . . . . . . . . . . . . . .

REMOVING THE SQUEEGEE

ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLING THE SQUEEGEE

62

63

63

ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . .

LEVELING THE SQUEEGEE . . . . . . .

ADJUSTING SQUEEGEE BLADE

DEFLECTION . . . . . . . . . . . . . . . . . .

SQUEEGEE BLADES . . . . . . . . . . . . . . . . .

REPLACING OR ROTATING THE

REAR SQUEEGEE BLADE . . . . . . .

REPLACING OR ROTATING THE

FRONT SQUEEGEE BLADE . . . . .

64

65

65

BELTS AND CHAINS . . . . . . . . . . . . . . . . .

BRUSH DRIVE BELT . . . . . . . . . . . . . .

STATIC DRAG CHAIN

TIRES

. . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PUSHING AND TRANSPORTING

THE MACHINE . . . . . . . . . . . . . . . . . . . . .

PUSHING THE MACHINE . . . . . . . . .

TRANSPORTING THE MACHINE

MACHINE JACKING

. . .

. . . . . . . . . . . . . . . . . .

STORAGE INFORMATION

FREEZE PROTECTION

. . . . . . . . . . . .

. . . . . . . . . . .

67

68

68

68

68

69

69

69

71

71

71

1

Home Find... Go To..

CONTENTS

Page

SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . .

GENERAL MACHINE

DIMENSIONS/CAPACITIES

FaST SYSTEM (OPTION)

. . . . . . . . . . .

. . . . . . . . . . . . .

73

73

74

ec--H2O SYSTEM (OPTION) . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

74

GENERAL MACHINE PERFORMANCE .

74

POWER TYPE 75

TIRES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MACHINE DIMENSIONS . . . . . . . . . . . . . .

75

76

2

Home Find... Go To..

5680 330459 (10--08)

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

The following symbols are used throughout this manual as indicated in their description:

WARNING: To warn of hazards or unsafe practices that could result in severe personal injury or death.

3. When using machine:

-- Go slow on inclines and slippery surfaces.

-- Use care when backing machine.

-- Follow mixing and handling instructions on chemical containers.

FOR SAFETY: To identify actions that must be followed for safe operation of equipment.

4. Before leaving or servicing machine:

-- Stop on level surface.

-- Set the parking brake.

-- Turn off machine and remove key.

This machine is designed solely for scrubbing dirt and dust in an indoor environment. Tennant does not recommend using this machine in any other environment.

The following information signals potentially dangerous conditions to the operator or equipment. Read this manual carefully. Know when these conditions can exist. Locate all safety devices on the machine. Then, take necessary steps to train machine operating personnel.

Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition.

WARNING: Batteries emit hydrogen gas.

Explosion or fire can result. Keep sparks and open flame away. Keep covers open when charging.

WARNING: Flammable materials can cause an explosion or fire. Do not use flammable materials in tank(s).

WARNING: Flammable materials or reactive metals can cause an explosion or fire. Do not pickup.

FOR SAFETY:

1. Do not operate machine:

-- Unless trained and authorized.

-- Unless operation manual is read and understood.

-- In flammable or explosive areas unless designed for use in those areas.

5. When servicing machine:

-- Avoid moving parts. Do not wear loose jackets, shirts, or sleeves when working on machine.

-- Block machine tires before jacking machine up.

-- Jack machine up at designated locations only. Block machine up with jack stands.

-- Use hoist or jack of that will support the weight of the machine.

-- Wear eye and ear protection when using pressurized air or water.

-- Disconnect battery connections before working on machine.

-- Avoid contact with battery acid.

-- Wear protective gloves and eye protection when handling white vinegar.

-- Use Tennant supplied or equivalent replacement parts.

6. When loading/unloading machine onto/off truck or trailer:

-- Turn off machine.

-- Use truck or trailer that will support the weight of the machine.

-- Use winch. Do not push the machine onto/off the truck or trailer unless the load height is 380 mm (15 in) or less from the ground.

-- Set parking brake after machine is loaded (option).

-- Block machine tires.

-- Tie machine down to truck or trailer.

2. Before starting machine:

-- Make sure all safety devices are in place and operate properly.

-- Check brakes and steering for proper operation (if so equipped).

5680 330459 (10--08)

Home Find... Go To..

3

SAFETY PRECAUTIONS

The safety labels appear on the machine in the locations indicated. If these or any label becomes damaged or illegible, install a new label in its place.

FLAMMABLE MATERIALS LABEL --

LOCATED ON THE UNDERSIDE OF

THE SOLUTION TANK COVER.

FOR SAFETY LABEL -- LOCATED ON

THE OPERATOR CONSOLE.

353417

4

BATTERY CHARGING LABEL -- LOCATED ON

THE UNDERSIDE OF THE SOLUTION TANK.

Home Find... Go To..

FLAMMABLE SPILLS LABEL -- LOCATED

ON THE OPERATOR CONSOLE.

5680 330459 (10--00)

OPERATION

OPERATOR RESPONSIBILITY

-

The operator’s responsibility is to take care of the daily maintenance and checkups of the machine to keep it in good working condition. The operator must inform the service mechanic or supervisor when the maintenance intervals are required as stated in the MAINTENANCE section of this manual.

-

Read this manual carefully before operating this machine.

FOR SAFETY: Do not operate machine, unless operation manual is read and understood.

-

Check the machine for shipping damage.

Check to make sure the machine is complete per shipping instructions.

-

Keep your machine regularly maintained by following the maintenance information in this manual. We recommend taking advantage of a regularly scheduled service contract from your Tennant representative.

-

Order parts and supplies directly from your authorized Tennant representative. Use the parts manual provided when ordering parts.

-

After operation, follow the recommended daily and hourly procedures stated in the

MAINTENANCE CHART.

OPERATION

07324

5680 330459 (10--00)

Home Find... Go To..

5

OPERATION

MACHINE COMPONENTS

B

A

D

C

H

F

J

K

A

I

M

E

G

L

C

6

Q

A. Solution tank

B. Solution tank fill opening

C. Recovery tank

D. Steering handles

E. Squeegee

F. Squeegee lever

G. Squeegee down pressure cams

H. Recovery tank drain hose

I.

Solution tank hose

J. Support arm

K. Stop arm

L. Batteries

M. Scrub head

N. Scrub brush access cover

O. FaST solution system (option)

ec- H2O

System Module (option)

P. Heavy duty scrub head strap

Q. Scrub brush idler door

M

N

O

P

5680 330459 (10--08)

Home Find... Go To..

OPERATION

CONTROL PANEL SYMBOLS

These symbols identify controls and displays on the machine:

Key switch

Variable flow or rate

Solution flow

Scrub brushes down and on

Scrub brushes up and off

Heavy scrub brush down pressure

Circuit breaker #1--scrub head actuator

Circuit breaker #2--vacuum fan motor

Circuit breaker #3--machine propel

Circuit breaker #4--left brush motor

Circuit breaker #5--right brush motor

Circuit breaker #6--FaST

Circuit breaker #6--ec--H2O

5680 330459 (10--08)

Home Find... Go To..

7

OPERATION

CONTROLS AND INSTRUMENTS

A

B

N

J

CB4

CB5

CB6

I

F

H

G

K

M

A. Operation label

B. Steering handles

C. On-off key switch

D. Scrub switch

E. Console height adjustment knob

F. Hourmeter

G. FaST system on/off switch (option)

ec- H2O system on/off switch (option)

H. ec- H2O system indicator light (option)

I.

Battery discharge indicator

J. Solution flow lever

K. Circuit breakers

L. Squeegee lever

M. Recovery tank drain hose

N. Solution tank drain hose

O. Power Kill Switch

O

E

K

B

C

L

CB1

CB2

CB3

D

10345

8

5680 330459 (10--08)

Home Find... Go To..

STEERING HANDLES

The steering handles control the machine speed and direction.

Forward: Rotate the steering handles forward. The further forward you rotate the steering handles, the faster the machine will go.

Backward: Rotate the steering handles backwards toward you.

Turning: Push the machine in the direction of the turn with the steering handles. The machine will turn on the swivel casters.

OPERATION

5680 330459 (10--00)

Home Find... Go To..

9

OPERATION

Stop: Release the steering handles.

The steering console height is adjustable.

Adjust: Turn the console adjustment knob counterclockwise to loosen the knob. Move the console up or down to the desired height. Then turn the knob clockwise to tighten the knob, and lock the console in position.

ON-OFF KEY SWITCH

The on-off key switch controls machine power with a key.

On: Turn the key to the right.

Off: Turn the key to the left.

10

Home Find... Go To..

5680 330459 (10--00)

SCRUB SWITCH

The scrub switch controls the scrubbing operations.

Lower brushes and start scrubbing: Press the top of the switch.

Raise brushes and stop scrubbing: Press the bottom of the switch.

NOTE: The scrub brushes do not start until the steering handles are rotated forward or backward.

NOTE: The scrub switch also controls the

FaST/ec-H2O system (option) when the

FaST/ec-H2O system is enabled with the

FaST/ec-H2O switch.

SCRUB HEAD STRAP (DISC HEAD)

The scrub head strap increases the scrub head pressure and puts the scrub head into heavy scrub mode.

The heavy scrub mode is used when deep scrubbing or floor stripping is necessary.

Start heavy scrub mode: With the scrub head in the up position, pull out on the scrub head strap until the scrub head drops into place. Lower the brushes and start scrubbing.

Stop heavy scrub mode: Press the bottom of the scrub switch. The scrub head will reset when it raises and stops scrubbing. When it is started again, the scrub head will operate at daily scrubbing pressure.

SQUEEGEE LEVER

The squeegee lever controls the squeegee and the vacuum system.

Lower squeegee and start vacuum: Move the squeegee lever up and to the left to unlock it, and then release the lever.

Raise squeegee and stop vacuum: Pull the lever up and move it to the right to lock the lever in the up position.

NOTE: Raise the squeegee before reversing the machine.

5680 330459 (10--08)

Home Find... Go To..

OPERATION

11

OPERATION

HOURMETER

The hourmeter records the number of hours the machine has been powered on. This information is useful when servicing the machine.

BATTERY DISCHARGE INDICATOR

The battery discharge indicator shows the charge level of the batteries.

When the batteries are fully charged, the indicator on the far right is lit. As the batteries discharge, the indicator will move along the display to the left.

Recharge the batteries when the indicator flashes.

NOTE: The battery discharge indicator will not reset from the flashing indicator unless the batteries have been fully charged.

FaST SWITCH (OPTION)

The FaST switch (option) enables the FaST

(Foam Scrubbing Technology) system. When the

FaST system is enabled, it is turned on and off with the scrub switch

Enable the FaST system: Press the top of the

FaST switch.

Enable conventional scrubbing: Press the bottom of the FaST switch.

NOTE: Disable the FaST system before using the machine for conventional scrubbing.

NOTE: The FaST system will not start until the steering handles are rotated forward or backward.

NOTE: Do not enable the FaST system with conventional cleaning detergents in the solution tank. Drain, raise and refill the solution tank with clear cool water only before operating the FaST system. Conventional cleaning detergents/ restorers may cause failure to the FaST solution system.

12

Home Find... Go To..

5680 330459 (3--08)

ec- H2O SWITCH (OPTION)

The ec--H2O switch (option) enables the ec--H2O

(electrically converted water) system. When the

ec--H2O system is enabled, it is turned on and off with the scrub switch.

Enable the ec--H2O system: Press the top of the

ec--H2O switch.

Enable conventional scrubbing: Press the bottom of the ec--H2O switch.

NOTE: Disable the ec--H2O system before using the machine for conventional scrubbing.

NOTE: The ec--H2O system will not start until the machine starts scrubbing.

NOTE: Do not enable the ec--H2O system with conventional cleaning detergents in the solution tank. Drain, raise and refill the solution tank with clear cool water only before operating the ec--H2O system. Conventional cleaning detergents/ restorers may cause failure to the ec--H2O solution system.

POWER KILL SWITCH

The power kill switch halts all power to the machine.

Halt: Hit the power kill switch.

Restart: Turn the power kill switch to the right to release the switch. Turn off the machine power, then turn on the machine power.

OPERATION

5680 330459 (10--08)

Home Find... Go To..

13

OPERATION

SOLUTION FLOW LEVER

The solution flow lever controls the amount of solution flow to the floor.

Increase: Push the lever forward.

Decrease: Pull the lever backward.

NOTE: A solenoid valve dispenses the solution to the scrub head. The valve opens when the steering handles are rotated forward, and closes when the steering handles are released in neutral position.

NOTE: When using the FaST or ec--H2O system

(option), the solution flow lever is nonfunctional.

The FaST and ec--H2O system flow rates are pre--set. The ec--H2O module has optional flow rate settings. If solution flow adjustments are required, contact an Authorized Service Center.

CIRCUIT BREAKERS

The circuit breakers are resettable electrical circuit protection devices. They stop the flow of current in the event of a circuit overload. Once a circuit breaker is tripped, reset manually by pressing the reset button after the breaker has cooled down.

If the overload that caused the circuit breaker to trip is still there, the circuit breaker will continue to stop current flow until the problem is corrected.

The circuit breakers are located on each side of the operator console.

The chart shows the circuit breakers and the electrical components they protect.

Circuit

Breaker

Rating

CB1

CB2

10 A

25 A

CB3

CB4

CB5

CB6

25 A

30 A

30 A

10 A

10 A

Circuit Protected

Machine power

Vacuum fan motor

Machine propel

Right brush motor

Left brush motor

FaST (option)

ec--H2O (option)

14

Home Find... Go To..

5680 330459 (10--08)

SOLUTION TANK HOSE

The solution tank hose is used to drain the solution tank. The drain hose plug is removed by turning the plug latch to loosen the plug and pulling the plug out of the drain hose. The drain hose is plugged by placing the hose plug in the end of the hose and turning the plug latch to tighten the plug.

RECOVERY TANK DRAIN HOSE

The recovery tank drain hose is used to drain the recovery tank. The drain hose plug is removed by turning the plug latch to loosen the plug and pulling the plug out of the drain hose. The drain hose is plugged by placing the hose plug in the end of the hose and turning the plug latch to tighten the plug.

SUPPORT ARM

The support arm holds up the solution tank when the tank is lifted. The support arm engages when the solution tank is lifted all the way open. The arm is released by pulling up on it.

OPERATION

5680 330459 (10--00)

Home Find... Go To..

15

OPERATION

STOP ARM

The stop arm prevents the solution tank from fully closing when the tank is lowered. Push the arm in to lower the solution tank completely.

SQUEEGEE DOWN PRESSURE CAMS

The squeegee down pressure cams adjust the squeegee deflection along the entire length of the squeegee.

Increase: Turn the cams clockwise.

Decrease: Turn the cams counter-clockwise.

PARKING BRAKE

The parking brake is controlled with a foot pedal and a release lever located by the squeegee.

Set: Push down on the foot pedal.

Release: Pull up on the release lever.

16

Home Find... Go To..

5680 330459 (10--00)

HOW THE MACHINE WORKS

The scrub components of the machine are a solution tank, scrub brushes or pads, a squeegee, a vacuum fan, and a recovery tank.

Water and detergent, from the solution tank, flow to the floor through a solution valve to the scrub brushes or pads. The brushes or pads scrub the floor. As the machine is moved forward the squeegee wipes the dirty solution off the floor, which is then picked up and drawn into the recovery tank.

The steering handles control the direction and speed of the machine in forward or reverse. By rotating the steering handles forward, the machine propels forward. By rotating the handles towards you, the machine propels backward.

Three different widths of scrub heads and squeegees are available for the machine.

The scrub head widths are as follows; the model

700 (700 mm), the model 800 (800 mm), and the model 900 (900 mm). The 700 mm squeegee is used with the 700 model scrub head, as well as the 800 mm with the model 800, and the 900 mm with the model 900.

OPERATION

5680 330459 (6--05)

Home Find... Go To..

17

OPERATION

FaST SCRUBBING SYSTEM (OPTION)

The FaST (Foam Scrubbing Technology) system operates by injecting the FaST PAK concentrate agent (A) into the system with a small amount of water and compressed air. This mixture creates a large volume of expanded wet foam.

The expanded foam mixture is then dispersed onto the floor (B) while the machine is scrubbing.

When the squeegee picks up the mixture, the patented foaming agent has collapsed and is recovered into the recovery tank.

The FaST system can be used with all double scrubbing and heavy duty scrubbing applications.

Using the FaST system can increase productivity by 30% by reducing your dump/fill cycle. It will also reduce chemical usage and storage space. One FaST PAK of concentrated agent can scrub up to 1 million sq. ft.

NOTE: Do not enable the FaST system with conventional cleaning detergents in the solution tank. Drain, raise and refill the solution tank with clear cool water only before operating the FaST system. Conventional cleaning detergents/ restorers may cause failure to the FaST solution system.

NOTE: Storage or transporting machines equipped with FaST in freezing temperatures requires special procedures. Check with a

TENNANT representative for advice.

A

B

The Safe Scrubbing Alternativer

18

Home Find... Go To..

5680 330459 (3--08)

ec- H2O SYSTEM (OPTION)

The ec--H2O (electrically converted water) system operates by producing electrically activated water for cleaning.

Normal water passes through a module where it is oxygenated and charged with an electric current.

The electrically converted water changes into a blended acidic and alkaline solution forming a neutral pH cleaner. The converted water attacks the dirt, breaks it into smaller particles, and pulls it off the floor surface allowing the machine to easily scrub away the suspended soil. The converted water then returns to normal water in the recovery tank.

The ec--H2O system can be used with all double scrubbing applications.

NOTE: Do not enable the ec--H2O system with conventional cleaning detergents in the solution tank. Drain, raise and refill the solution tank with clear cool water only before operating the ec--H2O system. Conventional cleaning detergents/ restorers may cause failure to the ec--H2O solution system.

NOTE: Storage or transporting machines equipped with ec--H2O in freezing temperatures requires special procedures. Check with a

TENNANT representative for advice.

OPERATION

5680 330459 (10--08)

Home Find... Go To..

19

OPERATION

PRE-OPERATION CHECKLIST

Check over this list of items before operating the machine:

-

Check under the machine for leaks.

-

Check for wire, string, or twine wrapped around the scrub brushes.

-

Check the squeegees for wear or damage.

-

Check the squeegee suction hose for obstructions.

-

Check the recovery tank cover seals for wear or damage.

-

Check that the vacuum fan inlet filter is clean.

-

FaST Scrubbing: Check the FaST PAK

(option) concentrate agent level, replace carton as needed. See the INSTALLING

THE FaST PAK AGENT section of the manual.

-

FaST or ec- H2O Scrubbing: Check that all conventional cleaning agents/restorers are drained and rinsed from the solution tank.

-

FaST or ec- H2O Scrubbing: Check that solution tank is filled with clear cool water

only.

20

Home Find... Go To..

5680 330459 (10--08)

INSTALLING FaST PAK AGENT (OPTION)

NOTE: Machine must be equipped with the FaST option before the FaST PAK agent can be installed.

1. Remove the perforated knock--outs from the

FaST PAK Floor Cleaning Concentrate carton. Do not remove the bag from the carton. Pull out the bag’s hose connector on the bottom of the bag and remove the hose cap from the connector.

NOTE: The FaST PAK Floor Cleaning

Concentrate is specifically designed for use with the FaST system scrubbing application.

NEVER use a substitute, machine damage will result.

FOR SAFETY: When using machine, always follow the handling instructions on chemical container.

2. Empty the solution tank. See the DRAINING

AND CLEANING THE TANKS section of the manual.

NOTE: When scrubbing with the FaST system option, use clean water only. Do not add cleaning agents in the solution tank. Conventional cleaning agents/restorers may cause failure to the FaST solution system..

3. .Raise the solution tank and remove the front cover to access the FaST PAK carton.

OPERATION

5680 330459 (11--05)

Home Find... Go To..

21

OPERATION

4. Place the FaST PAK carton in the carton holder under the front cover of the machine.

Connect the supply hose to the FaST PAK bag.

NOTE: If any dried concentrate is visible on the supply hose connector or the on the FaST PAK connector, soak and clean with warm water.

5. Make sure to connect the supply hose onto the hose storing plug when the supply hose is not connected to the FaST PAK. This will prevent the FaST solution system from drying out and clogging up the hose.

6. When replacing an empty FaST PAK carton, allow the new FaST PAK detergent to gravity feed into the system for several minutes prior to operating the FaST system. If the detergent does not flow out of the FaST

PAK, simply squeeze and release the hose several times. If the previous FaST PAK was run dry, it may take up to 3 minutes of operation to remove any air pockets in the system before you achieve maximum foaming.

22

Home Find... Go To..

5680 330459 (10--08)

OPERATION

STARTING THE MACHINE

1. Turn the machine power on.

FILLING THE TANKS

1. Start the machine.

2. Drive the machine to the filling site.

3. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, turn off machine, and remove key.

5680 330459 (3--08)

Home Find... Go To..

23

OPERATION

4. CONVENTIONAL SCRUBBING: Open the solution tank cover and partially fill the solution tank with water. Pour the required amount of detergent into the solution tank fill opening. Continue filling the solution tank with water 25 mm (1 in) below the bottom of the solution fill opening channel.

FOR SAFETY: When using machine, follow mixing and handling instructions on chemical containers.

5. FaST or ec--H2O SCRUBBING: Open the solution tank cover and fill the solution tank with clear cool water only.

NOTE: When cleaning using the FaST or ec- H2O option, USE CLEAR COOL WATER

ONLY. DO NOT add cleaning agents in solution tank. Conventional cleaning agents/restorers may cause failure to the system.

NOTE: (For conventional scrubbing)

Floor conditions, water condition, amount of soilage, types of soilage, and brush action all play an important role in determining the type and concentration of detergent used. For specific recommendations, contact your Tennant representative.

WARNING: Flammable materials can cause an explosion or fire. Do not use flammable materials in tank(s).

24

Home Find... Go To..

5680 330459 (10--08)

SCRUBBING AND BRUSH INFORMATION

D

Pick up oversized debris before scrubbing.

Pick up pieces of wire, string, twine, etc., which could become wrapped around the scrub brush.

D

Plan the scrubbing in advance. Try to arrange long runs with minimum stopping and starting. Do an entire floor or section at one time.

D

Try to scrub as straight a path as possible.

Avoid bumping into posts or scraping the sides of the machine. When scrubbing dead end aisles, start at the closed end of the aisle and scrub your way out. Overlap the scrub paths by a few centimeters (inches).

D

If you see poor scrubbing performance, stop scrubbing and refer to MACHINE

TROUBLESHOOTING.

Non-scuff polypropylene scrub brush -- This brush uses a softer, general purpose polypropylene bristle to lift lightly compacted soilage without scuffing high-gloss coated floors.

Nylon scrub brush -- Recommended for scrubbing coated floors. Cleans without scuffing.

Super abrasive bristle scrub brush -- Nylon fiber impregnated with abrasive grit to remove stains and soilage. Strong action on any surface, performing well on buildup, grease, or tire marks.

Heavy duty stripping pad -- This black pad is for stripping floors. Cuts through old heavy finishes easier, to prepare the floor for re-coating.

Stripping pad -- This brown pad is for stripping floors. Quickly and easily cuts through old finish to prepare the floor for re-coating.

Scrubbing pad -- This blue pad is for scrubbing floors. Removes dirt, spills and scuffs, leaving a clean surface ready for re-coating.

Buffing pad -- This red pad is for buffing floors.

Quickly cleans and removes scuff marks while polishing the floor to a high gloss.

Polishing pad -- This white pad is for polishing floors. Maintains a high gloss. Use for buffing very soft finishes and lower traffic areas, or use for polishing soft waxes on wood floors.

5680 330459 (11--05)

Home Find... Go To..

OPERATION

07218

25

OPERATION

Cylindrical polypropylene scrub brush -- This cylindrical brush uses a softer, general purpose polypropylene bristle to lift lightly compacted soilage without scuffing high-gloss coated floors.

Cylindrical nylon scrub brush -- This cylindrical brush is recommended for scrubbing coated floors. Cleans without scuffing.

Cylindrical super abrasive bristle scrub brush

-- Nylon fiber impregnated with abrasive grit to remove stains and soilage. Strong action on any surface, performing well on buildup, grease, or tire marks.

NOTE: Cylindrical scrub brushes must be installed with the herringbone patterns on the brushes pointing towards each other for best debris pick up.

1. Start the machine.

2. Drive the machine to the area to be scrubbed.

3. Heavy Scrub Mode only: With the scrub head in the up position, pull out on the scrub head strap, until the scrub head drops into place.

26

Home Find... Go To..

5680 330459 (11--05)

4. FaST SCRUBBING: Press the top of the

FaST switch to start the FaST system.

NOTE: Leave the FaST switch in the

CONVENTIONAL SCRUBBING position if not using the FaST system.

ec--H2O SCRUBBING: Press the top of the

ec--H2O switch to start the ec--H2O system.

NOTE: Leave the ec--H2O switch in the

CONVENTIONAL SCRUBBING position if not using the ec--H2O system.

NOTE: The ec--H2O system indicator light will not turn on until the machine starts scrubbing.

ec--H2O SCRUBBING: If an alarm sounds and the ec--H2O system indicator light begins to blink red, the ec--H2O module must be flushed to resume ec--H2O operation (See ec--H2O

MODULE FLUSH PROCEDURE)

NOTE: When the alarm sounds and the light blinks red, the machine will bypass the ec--H2O system. To continue scrubbing, turn the ec--H2O switch off and change over to conventional scrubbing.

ATTENTION: (ec- H2O model) Do not allow solution tank to run dry. ec- H2O module failure may result if operated without water for an extended period.

ec- H2O SYSTEM

INDICATOR LIGHT

CODE

Solid green

Blinking red

Solid red

CONDITION

Normal operation

Flush ec--H2O module

Contact Service Center

5680 330459 (10--08)

Home Find... Go To..

OPERATION

27

OPERATION

5. Press the top of the scrub switch to lower the scrub head and begin scrubbing.

6. Lower the squeegee to the floor with the squeegee lever.

7. Adjust the solution flow to the floor as needed.

NOTE: When using the FaST or ec--H2O system

(option), the solution flow lever is nonfunctional.

The FaST and ec--H2O system flow rates are pre--set. The ec--H2O module has optional flow rate settings. If solution flow adjustments are required, contact an Authorized Service Center.

8. Drive the machine forward and scrub as required.

WARNING: Flammable materials or reactive metals can cause an explosion or fire. Do not pickup.

28

Home Find... Go To..

5680 330459 (10--08)

DOUBLE SCRUBBING

Double scrubbing is a method for removing heavy floor accumulations. This is done by making two passes over the area to be cleaned with the machine.

Double scrubbing can be performed using the

FaST SCRUBBING SYSTEM (option),

ec--H2O SCRUBBING SYSTEM (option) or

CONVENTIONAL SCRUBBING methods.

1. First, make a pass over the area scrubbing with the squeegee up. This dispenses the solution/foam over the area allowing the solution/foam to soak on the floor.

NOTE: When using the FaST or ec--H2O system

(option), the solution flow lever is nonfunctional.

The FaST and ec--H2O system flow rates are pre--set. The ec--H2O module has optional flow rate settings. If solution flow adjustments are required, contact an Authorized Service Center.

FOR SAFETY: When using machine, go slow on inclines and slippery surfaces.

2. Lower the squeegee to the floor with the squeegee lever.

3. Then make a second pass scrubbing with the squeegee down.

OPERATION

5680 330459 (10--08)

Home Find... Go To..

29

OPERATION

STOP SCRUBBING

1. Release the steering handles.

2. Press the bottom of the scrub switch to stop scrubbing and raise the scrub brushes.

3. Propel the machine forward to pick up any solution left on the floor.

4. Raise the squeegee with the squeegee lever.

30

Home Find... Go To..

5680 330459 (9--02)

DRAINING AND CLEANING THE TANKS

When you are finished scrubbing, or when the vacuum fan shuts off, signalling a full recovery tank, the recovery tank should be drained and cleaned. The solution tank then can be filled again for additional scrubbing.

1. Stop scrubbing.

2. Drive the machine next to a floor drain or sink.

3. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, set parking brake, turn off machine, and remove key.

4. Set the machine parking brake.

OPERATION

5680 330459 (9--02)

Home Find... Go To..

31

OPERATION

5. Remove the recovery tank drain hose from the mounting clip.

6. Remove the recovery tank drain hose plug while holding the hose up, then slowly lower the drain hose to the floor drain or sink.

7. Check the solution tank, and empty any remaining solution with the solution tank drain hose.

8. Lift the solution tank to reach the recovery tank.

32

Home Find... Go To..

5680 330459 (9--02)

9. Flush out the inside of the recovery tank with clean water.

NOTE: DO NOT use steam to clean the tank.

Excessive heat can damage the tanks and components.

10. Rinse off the float sensor on the side of the recovery tank.

11. Remove and clean the vacuum fan filter located in the recovery tank. Clean by shaking dust or rinsing pleats with low pressure water. Insert the filter back in to the recovery tank when finished.

NOTE: Be sure the vacuum filter is dry before reinstalling it in the machine.

OPERATION

5680 330459 (3--08)

Home Find... Go To..

33

OPERATION

12. An optional debris screen is available for the recovery tank entry. If your machine is equipped with this screen, remove and clean it daily.

13. When the recovery, and solution tanks have completely drained, replace the drain hose plugs. Place the drain hoses back onto the mounting clips on the machine.

14. Pull up on the support arm and lower the solution tank. Push the stop arm in to completely lower the solution tank.

15. Cylindrical scrub head: Remove and clean the debris trough. Place the trough back in the scrub head.

34

Home Find... Go To..

5680 330459 (3--08)

OPERATION ON INCLINES

Drive the machine slowly on inclines.

FOR SAFETY: When using machine, go slow on inclines and slippery surfaces.

The maximum rated climb and descent incline with empty tanks is 8_, with full tanks is 6_.

STOP THE MACHINE

1. Stop scrubbing.

2. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, set parking brake, turn off machine, and remove key.

3. Set the machine parking brake.

OPERATION

5680 330459 (6--05)

Home Find... Go To..

35

OPERATION

POST-OPERATION CHECKLIST

Check over this list of items after you have finished scrubbing with the machine powered on:

-

Check the battery charge level.

NOTE: The reading on the battery discharge indicator may not be accurate when the machine is first powered on. Operate the machine a few minutes before reading the charge level of the batteries.

Check over this list of items with the machine powered off:

-

Check for wire, string, or twine wrapped around the scrub brushes.

-

Check the squeegees for wear or damage.

-

Check the squeegee suction hose for obstructions.

-

Drain and clean the recovery tank.

-

Clean the vacuum fan inlet filter.

-

Check under the machine for leaks.

-

Check the service records to determine maintenance requirements.

-

FaST scrubbing: If FaST PAK is empty after scrubbing, install the new FaST PAK or connect the supply hose to the storage plug.

36

Home Find... Go To..

5680 330459 (11--05)

OPERATION

MACHINE TROUBLESHOOTING

Problem

Trailing water -- poor or no water pickup

Vacuum fan will not turn on

Little or no solution flow to the floor

Poor scrubbing performance

Filter

Cause

Worn squeegee blades

Remedy

Rotate or replace squeegee blades

Squeegee out of adjustment

Vacuum hose clogged

Vacuum fan screen dirty

Debris caught on squeegee

Vacuum hose to squeegee or recovery tank disconnected or damaged

Adjust squeegee

Flush vacuum hoses

Clean inlet screen

Remove debris

Reconnect or replace vacuum hose

Solution tank not completely closed Check for obstructions

Heavy duty batteries posts too tall, file down posts

Machine front cover mounted too high, mount cover lower

Torn seals on solution tank

Recovery tank full

Foam filling recovery tank

Replace seals

Drain recovery tank

Empty recovery tank

Use less or change detergent

Use a defoamer

Recovery tank sensor dirty or stuck Clean or replace

Vacuum fan circuit breaker tripped Reset circuit breaker

Solution tank empty

Solution control cable broken or out of adjustment

Fill solution tank

Replace and/or adjust cable

Solution flow turned off

Solution supply lines plugged

Solution supply line filter dirty

Solution solenoid clogged or stuck

Debris caught on scrub brushes or pads

Improper detergent, brush, or pad used

Worn scrub brush(es) or pad(s)

Scrub brush motor circuit breaker(s) tripped

Turn solution flow on

Flush solution supply lines

Clean filter

Clean or replace

Remove debris

Contact Service Center

Replace scrub brush(es) or pad(s)

Reset circuit breaker(s)

Low battery charge

Reduce scrub brush down pressure

Uneven brush pressure, level scrub head

Contact Service Center

Charge batteries until the charger automatically turns off

5680 330459 (3--08)

Home Find... Go To..

37

OPERATION

Problem

Poor propelling traction

FaST System (option) does not operate

Cause

Tires slip on oily or waxed floors

Uneven brush down pressure

FaST switch is set for Conventional scrubbing

FaST circuit breaker tripped

Clogged FaST PAK supply hose and/or connectors

FaST PAK carton is empty or not connected

Clogged flow control orifice and/or screen

Faulty pump or air compressor

Clogged filter screen

FaST system is not primed

Mineral deposit build--up in module

Remedy

Contact Service Center

Level scrub head

Set the FaST switch for FaST system scrubbing

Determine cause and reset the 10A circuit breaker button

Soak connector and hose in warm water and clean

Replace FaST PAK carton and/or connect supply hose

Remove and clean orifice and/or screen

Contact Service Center

Drain solution tank, remove and clean filter screen

To prime, operate the FaST solution system for 3 minutes

Flush module (See ec--H2O

MODULE FLUSH PROCEDURE)

ec- H2O Model:

ec--H2O system indicator light blinking red

ec- H2O Model:

Alarm sounds

ec- H2O Model:

ec--H2O system indicator light solid red

ec- H2O Model:

ec--H2O system indicator light does not turn on

ec- H2O Model:

No water flow

Defective module

Defective light or module

Clogged module

Defective solution pump

Contact Service Center

Contact Service Center

Contact Service Center

Replace solution pump

38

Home Find... Go To..

5680 330459 (10--08)

MAINTENANCE

9

3

MAINTENANCE

10

1

7

4

2

8

6

11

6 8

5

353417

MAINTENANCE CHART

Interval

Daily

Key

2

Description

Squeegee

8 Scrub brushes or pads

1 Recovery tank

3 Solution tank

3 Vacuum fan filter

Machine

6 Disk scrub head skirt

6 Cylindrical scrub head skirts

10 FaST PAK supply hose and connector (option)

50 Hours

10 FaST Filter screen

(option)

8 Cylindrical brushes

100 Hours

4 Rear casters

11 Cylindrical scrub brush drive belts

Procedure

Check for damage and wear

Check deflection and leveling

Check for damage and wear

Clean tank

Clean float sensor

Clean vacuum fan filter

Clean debris screen (option)

Clean

Clean

Check for leaks

Check for damage and wear

Check adjustment

Check for damage and wear

Clean and connect hose to storing plug when not in use

Clean

Check taper and rotate front to rear

Lubricate

Check tension

Lubricant/

Fluid

--

--

--

--

--

--

--

--

--

--

--

--

--

--

No. of

Service

Points

1

1

1

1

1

1

4

4

1

1

1

2

1

1

--

--

SPL

--

1

2

2

2

5680 330459 (3--08)

Home Find... Go To..

39

MAINTENANCE

Interval Key Description

500 Hours 9 Vacuum fan motor

1000

Hours

10 FaST water and air filters

(option)

7 Scrub brush motors

5 Propelling motor

5 Transaxle

Replace

Procedure

Check motor brushes

Check motor brushes

Check motor brushes

Check lubricant level

SPL -- Special lubricant, Lubriplate EMB grease (TENNANT part no. 01433--1)

GL -- SAE 90 weight gear lubricant

Lubricant/

Fluid

--

--

No. of

Service

Points

1

1

--

--

GL

2

1

1

40

Home Find... Go To..

5680 330459 (3--08)

LUBRICATION

REAR CASTERS

The rear casters each have one grease fitting on the caster swivel. Lubricate the caster with a grease gun containing Lubriplate EMB grease

(TENNANT part no. 01433--1) every 100 hours of machine operation.

TRANSAXLE

Check the transaxle lubricant level every

1000 hours of operation by removing one of the orange filler plugs. If needed, add SAE 90 weight gear lubricant.

BATTERIES

The batteries are unique in that they hold their power for long periods of time. The lifetime of the batteries is limited by the number of charges the batteries receive. To get the most life from the batteries, charge them when all the battery discharge indicator segments shut off (20% charge left). Use an automatic charger with the proper rating for the batteries.

Periodically clean the top surface of the batteries and the terminals, and check for loose connections. Use a strong solution of baking soda and water. Brush the solution sparingly over the battery tops, terminals, and cable clamps. Do not allow any baking soda solution to enter the batteries. Use a wire brush to clean the terminal posts and the cable connectors. After cleaning, apply a coating of clear battery post protectant to the terminals and the cable connectors. Keep the tops of the batteries clean and dry.

5680 330459 (9--02)

Home Find... Go To..

MAINTENANCE

41

MAINTENANCE

Keep all metallic objects off the top of the batteries, which may cause a short circuit.

Replace any worn or damaged wires.

Never add acid to the batteries, only distilled water. Always keep the battery caps on, except when adding water or taking hydrometer readings.

Check the electrolyte level in each battery cell before and after charging, and after every

50 hours of operation. Do not charge the batteries unless the fluid is slightly above the battery plates.

If needed, add just enough distilled water to cover the plates. Never add acid to the batteries. Do not overfill. Always keep the battery caps on, except when adding water or taking hydrometer readings.

Measuring the specific gravity, using a hydrometer, is a way to determine the charge level and condition of the batteries. If one or more of the battery cells test lower than the other battery cells (0.050 or more), the cell is damaged, shorted, or is about to fail.

NOTE: Do not take readings immediately after adding distilled water. If the water and acid are not thoroughly mixed, the readings may not be accurate. Check the hydrometer readings against the following chart to determine the remaining battery charge level:

SPECIFIC GRAVITY at 27_ C (80_F)

1.265

1.223

1.185

1.148

1.110

BATTERY

CHARGE

100% Charged

75% Charged

50% Charged

25% Charged

Discharged

NOTE: If the readings are taken when the battery

electrolyte is any temperature other than 27_ C,

the reading must be temperature corrected. Add or subtract to the specific gravity reading 0.004,

4 points, for each 6_ C above or below 27_C.

42

Home Find... Go To..

5680 330459 (9--02)

04380

CHARGING THE BATTERIES

1. Drive the machine to a flat, dry surface in a well-ventilated area.

2. Turn the machine power off and set the parking brake if your machine has this option.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, set parking brake, and turn off machine.

3. Lift up the solution tank to get access to the batteries.

NOTE: The solution tank must be empty.

4. Check the water level in all battery cells. If the level is low, add just enough distilled water to cover the plates. DO NOT

OVERFILL. The batteries can overflow during charging due to expansion.

NOTE: Make sure the battery caps are in place while charging.

FOR SAFETY: When maintaining or servicing machine, avoid contact with battery acid.

5. Plug the charger connector into the battery connector.

WARNING: Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep covers open when charging.

6. Plug the battery charger into the wall outlet.

5680 330459 (9--02)

Home Find... Go To..

MAINTENANCE

43

MAINTENANCE

NOTE: If the red “ABNORMAL CYCLE” lamp lights when the TENNANT charger is plugged into a wall outlet, the charger cannot charge the battery and there is something wrong with the battery.

7. The TENNANT charger will start automatically. When the batteries are fully charged, the TENNANT charger will automatically turn off.

8. After the charger has turned off, unplug the charger from the wall outlet.

9. Unplug the charger connector from the battery connector on the machine.

FOR SAFETY: When maintaining or servicing machine, avoid contact with battery acid.

10. Check the electrolyte level in each battery cell after charging. If needed, add distilled water to raise the electrolyte level to about

12 mm below the bottom of the sight tubes.

11. Lower the solution tank.

12. Pull up on the support arm and rotate the stop arm out of the way to allow the solution tank to close completely.

ELECTRIC MOTORS

The carbon brushes on the vacuum fan motor should be inspected after every 500 hours of machine operation. The carbon brushes on the scrub brush motors and propelling motor should be inspected after every 1000 hours of machine operation. The carbon brushes on the scrub brush motors,and propelling motor should be inspected after every 1000 hours of machine operation.

44

Home Find... Go To..

5680 330459 (9--02)

SCRUB HEAD

The machine is equipped with a disk brush scrub head. The scrub head contains skirts to control over-spray from the scrub brushes.

DISK BRUSH SCRUB HEAD SKIRT

Make sure the scrub head skirt touches the floor all the way around when the scrub head is lowered. Check the skirt for damage or wear daily.

NOTE: Replace the scrub head skirt when it is damaged or no longer is able to touch the floor.

CYLINDRICAL BRUSH SCRUB HEAD SKIRTS

The four head skirts should just touch the floor.

Check the skirts for damage or wear daily.

ADJUSTING THE SCRUB HEAD SKIRTS

1. Lower the scrub head on a level floor.

2. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, and turn off machine.

3. Check to see if the scrub head skirts touch the floor.

4. If any of the skirts needs adjusting, loosen the retainer strip hardware and slide the skirt to the proper adjustment. Tighten the retainer strip hardware.

REPLACING THE SCRUB HEAD SKIRTS

1. Raise the scrub head.

2. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, and turn off machine.

3. Remove the retainer strip and hardware.

4. Replace the old skirt with a new skirt and mount in place with the retainer strip and hardware.

5680 330459 (11--05)

Home Find... Go To..

MAINTENANCE

45

MAINTENANCE

REMOVING OR REPLACING THE SCRUB

HEAD

The scrub heads are available in three widths.

NOTE: When you change to a different width scrub head, be sure to install the appropriate width squeegee and machine front cover.

1. Lower the scrub head.

2. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, set parking brake, and turn off machine.

3. Remove the machine front cover.

46

Home Find... Go To..

5680 330459 (6--05)

4. Disconnect the solution line from the scrub head tee fitting.

MAINTENANCE

5. Disconnect the wire harness from each scrub motor.

6. Disconnect the scrub head from the guide by removing the clevis pin.

5680 330459 (9--02)

Home Find... Go To..

47

MAINTENANCE

7. Disconnect the lift arms from the scrub head by removing the two clevis pins.

8. Mark the location of the actuator tube on the actuator shaft before disconnecting the actuator. Disconnect the actuator from the scrub head by removing the clevis pin.

9. To install the scrub head, connect the lift arms to the scrub head with the two clevis pins.

10. Connect the scrub head to the guide with the clevis pin.

11. Make sure the actuator tube lines up with the mark made earlier on the actuator shaft. If not, turn the actuator tube until it does.

Connect the actuator to the scrub head with the clevis pin.

12. Connect the wire harness.

13. Connect the solution line to the scrub head tee fitting.

48

Home Find... Go To..

5680 330459 (9--02)

LEVELING THE SCRUB HEAD

1. Make sure the scrub head is lowered to the floor.

2. Check the level of the scrub head by measuring the distance from the top of the scrub head, to the floor at all four corners.

The scrub head should measure the same on all four corners.

3. If the scrub head is not level at all four corners, loosen the jam nut on the adjustment screw located on the top of the scrub head. Turn the adjustment screw until the scrub head measures level. Tighten the jam nut.

4. Install the machine front cover.

5. Cylindrical scrub head: Check the brush pattern as described in CHECKING AND

ADJUSTING CYLINDRICAL BRUSH

PATTERN .

MAINTENANCE

5680 330459 (11--05)

Home Find... Go To..

49

MAINTENANCE

SCRUB BRUSHES AND PADS

The scrub brushes should be checked daily for wire or string tangled around the brush or drive hub. The brushes should also be checked for any damage and wear.

DISK BRUSHES

The disk brushes should be replaced if large amounts of bristles are missing, or if the remaining bristles’ length is less than 10 mm.

Cleaning pads must be placed on pad drives before they are ready to use. The cleaning pad is held in place by a pad holder.

Cleaning pads need to be cleaned immediately after using with soap and water. Do not wash the pads with a pressure washer. Hang dry pads, or lie flat to dry.

NOTE: Be sure to replace brushes and pads in sets. Otherwise one brush or pad will be more aggressive than the other.

REPLACING THE DISK BRUSHES OR PADS

1. Raise the scrub head.

2. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, set parking brake, and turn off machine.

3. Open the access cover on either corner of the scrub head.

50

Home Find... Go To..

5680 330459 (9--02)

4. Turn the brush/pad driver until you can see the brush spring clip.

MAINTENANCE

5. Press the spring clip together with your thumb and index finger. The brush/pad driver will drop off the drive hub.

6. Pull the brush/pad driver out from under the scrub head.

5680 330459 (9--02)

Home Find... Go To..

51

MAINTENANCE

7. PAD DRIVER ONLY: Turn the pad driver over to access the spring clip underneath.

8. Press the spring clip together with your thumb and index finger to remove the center disk.

9. Flip or replace the scrub pad, center the scrub pad on the pad driver.

52

Home Find... Go To..

5680 330459 (9--02)

10.Replace the center disk to secure the pad in place on the driver.

MAINTENANCE

11. Place the new scrub brush/pad driver on the floor in front of the scrub head. Push the brush under the scrub head.

12. Line up the drive socket with the drive plug.

13. Lift the scrub brush/pad driver assembly into the drive plug.

14. Check to make sure the brush/pad driver assembly is securely mounted on the brush drive hub.

15. Close the scrub head access cover.

16. Repeat for the other brush/pad driver.

5680 330459 (6--00)

Home Find... Go To..

53

MAINTENANCE

CYLINDRICAL BRUSHES

Check the brush taper and rotate the brushes from front-to-rear every 50 hours of operation, for maximum brush life and best scrubbing performance.

The cylinder brushes should be replaced if large amounts of bristles are missing, or if the remaining bristles’ length is less than 10 mm

(0.38 in).

NOTE: Be sure to replace brushes in sets.

Otherwise one brush will be more aggressive than the other.

REPLACING THE CYLINDRICAL BRUSHES

1. Raise the scrub head.

2. Turn the machine power off and set the parking brake if your machine has this option.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, and turn off machine.

3. Push down on the mounting spring and the idler door, then pull out on the bottom of the door. Push down on the spring until the door releases from the scrub head. Pull the idle plug off the brush.

4. Pull the brush out of the scrub head.

5. With the double row end of the brush towards you, guide the brush onto the drive hub.

NOTE: Use the double rows on the idler end of the brush.

54

Home Find... Go To..

5680 330459 (11--05)

6. Insert the Idler plug of the idler door into the brush.

7. Push down on the door to catch the door in the scrub head, then pull up on the door to latch it in the spring.

8. Repeat for the other brush on the other side of the scrub head.

NOTE: The idler doors have stamped letters that correspond with letters on the scrub head. Make sure the idler doors are placed back on the same side of the scrub head that they were originally removed from.

CHECKING AND ADJUSTING CYLINDRICAL

BRUSH PATTERN

NOTE: Check the tires for correct tire pressure and make sure the solution tank is full before checking or adjusting the brush pattern.

1. Apply chalk, or some other material that will not blow easily away, to a smooth, level floor.

2. Raise the scrub head. Position the scrub head over the chalked area.

3. Set the parking brake if your machine has this option.

4. Lower the scrub head for 15 to 20 seconds while keeping the scrub head in one spot in the chalked area.

NOTE: If chalk or other material is not available, allow the brushes to spin on the floor for two minutes. A polish mark will remain on the floor.

5. Raise the scrub head and move the machine away from the chalked area. Turn the machine power off.

5680 330459 (11--05)

Home Find... Go To..

MAINTENANCE

55

MAINTENANCE

6. Observe the shape of the brush patterns. If the brush patterns have parallel sides, the brushes do not need taper adjustment.

If one or both of the brush patterns are tapered, the brushes will have to be adjusted to straighten the brush pattern.

A. Remove the idler door by pushing down on the mounting spring and the idler door, then pulling out on the bottom of the door. Push down on the spring until the door releases from the scrub head.

Pull the idle plug off the brush.

B. While holding the flat end of the idler shaft with a wrench, loosen the mounting screw on the outside of the idler door.

56

Home Find... Go To..

5680 330459 (11--05)

10355

10356

C. Turn the idler shaft to raise or lower the end of the brush as needed to straighten the brush pattern. Tighten the mounting screw.

D. Check the brush patterns again and readjust as necessary.

The brush patterns should be the same width. If one is narrower then the other, loosen the jam nut on the adjustment screw located on the top of the scrub head.

Turn the adjustment screw clockwise to increase the front brush pattern width. Turn the adjustment screw counter-clockwise to increase the back brush pattern width.

Check the brush patterns again. Adjust until the front and back patterns are the same width.

Tighten the jam nut.

SOLUTION SYSTEM

RECOVERY TANK

The recovery tank stores recovered solution. The recovery tank should be drained and cleaned daily. The outside of the tank can be cleaned with vinyl cleaner.

NOTE: DO NOT use steam to clean the tank.

Excessive heat can damage the tanks and components.

MAINTENANCE

5680 330459 (03--08)

Home Find... Go To..

57

MAINTENANCE

Rinse and wipe off the sensors daily on machines with float sensors installed inside the recovery tank.

A vacuum fan filter is located in the recovery tank.

Remove and clean this filter daily. Clean by shaking dust or rinsing pleats with low pressure water.

NOTE: Be sure the vacuum filter is dry before reinstalling it in the machine.

An optional debris screen is available for the recovery tank entry. If your machine is equipped with this screen, remove and clean it daily.

SOLUTION TANK

The solution tank stores the cleaning solution.

The solution tank does not require regular maintenance. If deposits form on the bottom of the tank, rinse the tank with a strong blast of warm water. The tank can be flushed through the fill opening and top access hole.

The solution tank contains one standard solution line filter. If the filter becomes dirty, the solution flow will be reduced. Check and clean these filters if necessary.

NOTE: DO NOT use steam to clean the tank.

Excessive heat can damage the tanks and components.

58

Home Find... Go To..

5680 330459 (3--08)

MAINTENANCE

FaST SYSTEM (OPTION)

FaST SYSTEM MAINTENANCE

Every 1000 hours replace the water filter and air filter located in the FaST detergent injector. Order filter kit p/n 9003009.

To access the detergent injector assembly, lower the scrub head and remove the front cover.

Remove the injector assembly from clamps.

Replace the water and air filter. An 8mm hex wrench required to install new water filter.

Air Filter

(50 Mesh/Brown)

Water Filter

(50 Mesh/Brown)

5680 330459 (3--08)

Home Find... Go To..

59

MAINTENANCE

FaST SYSTEM FILTER SCREEN

The FaST system filter screen is located under the solution tank and filters the water from the solution tank as it flows into the FaST system.

Remove the filter screen bowl and clean the filter screen after every 50 hours of machine operation.

Empty the solution tank before removing the filter.

FaST SUPPLY HOSE CONNECTOR

The FaST supply hose connector is located below the FaST PAK holder. Soak the connector in warm water if detergent buildup is visible. When a FaST

PAK carton is not installed, store the supply hose connector on the storing plug to prevent the hose from clogging.

60

Home Find... Go To..

5680 330459 (3--08)

ec- H2O SYSTEM (OPTION)

ec- H2O MODULE FLUSH PROCEDURE

This procedure is only required when an alarm sounds and the ec--H2O system indicator light begins to blink red.

1. Drain the solution tank and recovery tank of all water.

2. Pour 2 gallons (8 liters) of white or rice vinegar into the solution tank at full strength.

Do not dilute.

(p/n 1050552 -- Vinegar, 2.5 gals/10 ltrs)

NOTE: Use white or rice vinegar only. The acidity level should be between 4--8%. Do not use other acids for this procedure.

FOR SAFETY: When servicing machine, wear protective gloves and eye protection when handling vinegar.

3. Disconnect the black connector fitting at the scrub head and place the hose into a bucket.

To access the connector fitting, you may have to remove the front cover from the machine.

4. Turn the key to the on position.

5. Press and release the ec--H2O module flush switch to start the flush cycle. The module is located behind the front cover.

NOTE: The module will automatically shut off when the flush cycle is complete (approx. 7 minutes). The module must run the full 7 minute cycle in order to reset the system indicator light and alarm.

Repeat flush procedure if the ec--H2O module does not reset. If module fails to reset, contact an Authorized Service Center.

5680 330459 (10--08)

Home Find... Go To..

MAINTENANCE

61

MAINTENANCE

SQUEEGEE

The squeegee assembly channels water into the vacuum fan suction. The front blade channels the water, and the rear blade wipes the floor.

Check the squeegee blades for damage and wear daily. Rotate or replace either of the squeegee blades if the leading edge is torn or worn half-way through the thickness of the blade.

The squeegee can be adjusted for leveling and deflection. The deflection and leveling of the squeegee blades should be checked daily, or when scrubbing a different type of floor.

The squeegee assembly can be removed from the squeegee pivot to prevent damage during transport of the machine, or when changing to a different squeegee width. The squeegees are available in three widths to be used with the three different model scrub heads; model 700 (700 mm), model 800 (800 mm), and model 900 (900 mm).

REMOVING THE SQUEEGEE ASSEMBLY

1. Raise the squeegee.

2. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, set parking brake, and turn off machine.

3. Remove the squeegee suction hose from the squeegee.

62

Home Find... Go To..

5680 330459 (9--06)

4. Loosen the two mounting knobs.

5. Pull the squeegee off the machine.

INSTALLING THE SQUEEGEE ASSEMBLY

1. Make sure the squeegee is raised.

2. Place the squeegee under the squeegee pivot.

3. Slide the squeegee frame onto the squeegee pivot.

4. Tighten the mounting knobs.

5. Push the squeegee suction hose on the squeegee.

LEVELING THE SQUEEGEE

Leveling of the squeegee assures even contact the length of the squeegee blade with the surface being scrubbed. Make sure this adjustment is done on an even, level floor.

1. Turn the machine power on.

2. Lower the squeegee.

3. Drive the machine forward, then turn the machine power off.

4. Look at the deflection of the squeegee blade, over the full length of the squeegee blade.

MAINTENANCE

5680 330459 (9--06)

Home Find... Go To..

63

MAINTENANCE

5. If the deflection is not the same over the full length of the blade, turn the squeegee leveling bolt counter-clockwise to increase the deflection at the ends of the squeegee.

Turn the squeegee leveling bolt clockwise to decrease the deflection at the ends of the squeegee blade.

6. Drive the machine forward again with the squeegee down to check the squeegee blade deflection.

7. Readjust the squeegee blade deflection if necessary.

ADJUSTING SQUEEGEE BLADE DEFLECTION

Deflection is the amount of curl the squeegee blade has when the machine moves forward with the squeegee lowered to the floor. The best deflection is when the squeegee wipes the floor just dry with a minimum amount of deflection.

1. Turn the machine power on.

2. Lower the squeegee.

3. Drive the machine forward, and look at the deflection of the squeegee blade. The correct amount of deflection is 12 mm for scrubbing smooth floors and 15 mm for rough floors.

4. Turn the machine power off.

5. To adjust the amount of deflection, turn the squeegee deflection cams counter-clockwise to decrease the blade deflection.

Turn the squeegee deflection cams clockwise to increase blade deflection.

6. Drive the machine forward again to check the squeegee blade deflection.

7. Readjust the squeegee blade deflection if necessary.

64

Home Find... Go To..

12 mm

5680 330459 (9--06)

03719

SQUEEGEE BLADES

The squeegee has two squeegee blades, the front and back. Each blade has four wiping edges. To use them all, start with one wiping edge. To use the next wiping edge, rotate the blade end-for-end.

To use the next wiping edge, rotate the top edges down, bottom edges up. To use the last edge, rotate the blade end-for-end.

Replace any worn or damaged squeegee blades.

REPLACING OR ROTATING THE REAR

SQUEEGEE BLADE

1. Make sure the squeegee is raised off the floor.

2. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, set parking brake, and turn off machine.

3. Loosen the two retention knobs, one at each end on the squeegee.

MAINTENANCE

5680 330459 (9--02)

Home Find... Go To..

65

MAINTENANCE

4. Pull off the rear retaining band.

5. Pull off the rear squeegee blade.

6. Insert the rotated or new squeegee blade and then insert the retainer band.

7. Tighten the two retention knobs until the ends of the front and rear squeegee blades touch. Do not overtighten.

66

Home Find... Go To..

5680 330459 (9--02)

REPLACING OR ROTATING THE FRONT

SQUEEGEE BLADE

1. Make sure the squeegee is raised off the floor.

2. Turn the machine power off.

FOR SAFETY: Before leaving or servicing machine, stop on level surface, set parking brake, and turn off machine.

3. Remove the squeegee from the machine.

See REMOVING THE SQUEEGEE

ASSEMBLY.

4. Remove the rear squeegee blade and retainer. See REPLACING OR ROTATING

THE REAR SQUEEGEE BLADE.

5. Loosen the two remaining knobs on top of the squeegee assembly.

6. Pull the retainer plate back and pull out the front squeegee blade of the squeegee frame.

7. Insert the rotated or new squeegee blade in the squeegee frame, lining up the slots in the blade with the tabs on the retainer plate.

MAINTENANCE

8. Push the retainer plate forward. Tighten the two outside knobs on top of the squeegee assembly.

9. Insert the rear squeegee blade and retainer.

Tighten the two rear blade retention knobs until the ends of the front and rear squeegee blades touch. Do not overtighten.

10. Install the squeegee assembly on the squeegee pivot. See INSTALLING THE

SQUEEGEE ASSEMBLY.

11. Adjust the squeegee blade leveling and deflection as stated in LEVELING THE

SQUEEGEE and ADJUSTING SQUEEGEE

BLADE DEFLECTION.

5680 330459 (6--05)

Home Find... Go To..

67

MAINTENANCE

BELTS AND CHAINS

BRUSH DRIVE BELT

The two brush drive belts are located on the cylindrical brush scrub head. The belts drive the cylindrical brushes. Proper new belt tension is a 3 mm (0.1 in) deflection from a force of 1.37 to 1.48

kg (3.0 to 3.26 lb) at the belt midpoint.

When reusing an old belt, measure and record the belt tension before removal, so that the belt can be reinstalled at the same tension.

If the old belt tension was not recorded, the recommended force per old belts is

1.03 to 1.14 kg (2.28 to 2.52 lb) with a deflection of 3 mm (0.1 in).

Check the belt tension and wear every 100 hours of operation.

STATIC DRAG CHAIN

A static drag chain prevents the buildup of static electricity in the machine. The chain is attached to the transaxle.

Make sure the chain is always touching the floor.

TIRES

The standard front tires are foam filled.

The front wheel lug nuts should be tightened to

102 to 115 Nm.

68

Home Find... Go To..

5680 330459 (11--05)

PUSHING AND TRANSPORTING THE

MACHINE

PUSHING THE MACHINE

If the machine becomes disabled, it can be pushed if necessary.

Unplug the drive motor from the electrical harness before attempting to push a disabled machine.

The machine will become easier to maneuver when it is unplugged.

ATTENTION! Do not push the machine for a long distance and without unplugging the drive motor or damage may occur to the propelling system.

Only push a disabled machine for a very short

distance and do not exceed 3.2 kp/h. It is NOT intended to be pushed for a long distance or at a high speed.

TRANSPORTING THE MACHINE

1. Position the rear of the machine at the loading edge of the truck or trailer.

FOR SAFETY: Use truck or trailer that will support the weight of the machine.

NOTE: Empty the recovery and solution tanks before transporting the machine.

2. If the loading surface is not horizontal or is higher than 380 mm from the ground, use a winch to load machine.

If the loading surface is horizontal AND is

380 mm or less from the ground, the machine may be pushed onto the truck or trailer.

3. To winch the machine onto the truck or trailer, attach the winching chains to the rear tie down locations on either side of the machine frame by the rear casters.

5680 330459 (9--02)

Home Find... Go To..

MAINTENANCE

69

MAINTENANCE

4. Unplug the drive motor from the electrical harness before attempting to winch the machine. The machine will become easier to maneuver when it is unplugged.

5. Position the machine onto the truck or trailer as far as possible. If the machine starts to veer off the centerline of the truck or trailer, stop and straighten the machine.

6. Lower the scrub head with the brushes or pad drivers installed, lower the squeegee when transporting the machine. Block the machine tires and tie down the machine to the truck or trailer before transporting.

NOTE: Do not use the steering handles to secure the machine for transport.

Secure a strap over the top of the machine to prevent the machine from tipping.

The rear tie-down locations are on either side of the machine frame by the rear casters.

7. If the loading surface is not horizontal or is higher than 380 mm from the ground, use a winch to unload machine.

If the loading surface is horizontal AND is

380 mm or less from the ground, the machine may be pushed off the truck or trailer.

FOR SAFETY: When unloading machine off truck or trailer, use winch. Do not push the machine off the truck or trailer unless the loading surface is horizontal

AND 380 mm or less from the ground.

70

Home Find... Go To..

5680 330459 (9--02)

MACHINE JACKING

Check that both the solution and recovery tanks are empty before attempting to jack up the machine.

You can jack up the machine for service anywhere under the recovery tank. Use a piece of wood to distribute the machine weight load.

Always stop the machine on a flat level surface and block the machine tires before jacking up the machine.

FOR SAFETY: When servicing machine, block machine tires before jacking machine up.

FOR SAFETY: When servicing machine, jack machine up at designated locations only. Block machine up with jack stands.

STORAGE INFORMATION

The following steps should be taken when storing the machine for extended periods of time.

1. Drain and clean the solution and recovery tanks.

2. Park the machine in a cool, dry area.

3. Remove the batteries, or charge them after every three months.

FREEZE PROTECTION

1. Drain the solution tank and recovery tank of all water.

2. Pour 2 gallons (8 liters) of recreational vehicle (RV) antifreeze into the solution tank at full strength. Do not dilute.

FOR SAFETY: Avoid eye contact with antifreeze. Wear safety glasses.

3. Turn the machine power on and operate the solution flow system. Turn the machine off when the red RV antifreeze is visible.

If your machine is equipped with the off--aisle wand option, operate the off--aisle wand for a few seconds to protect the pump.

5680 330459 (9--02)

Home Find... Go To..

MAINTENANCE

71

MAINTENANCE

Continue with the freeze protection procedure if machine is equipped with the ec--H2O system.

ec- H2O Model:

4. Press and release the flush switch on the ec--H2O module to cycle the antifreeze through ec--H2O system.When the antifreeze is visible, press the switch again to turn off the module. The module is located behind the front cover.

IMPORTANT: Before operating machine, the antifreeze must be flushed from the module as described below.

If the antifreeze is not properly flushed from the

ec--H2O system, the ec--H2O module may detect an error and not function (ec--H2O switch indicator light will turn red). If this occurs, reset key and repeat the flush procedure as described below.

Flushing antifreeze from ec--H2O module:

1.

Drain the antifreeze from the solution tank into a bucket.

2.

Fill the solution tank with cool water until full

(See FILLING SOLUTION TANK).

3 Disconnect the black connector fitting at the scrub head and place the hose into a bucket.

To access the connector fitting, you may have to remove the front cover from the machine.

4.

Press and release the ec--H2O module flush switch to start the flush cycle. The module is located behind the front cover.

When the water turns clear, press the module switch again to stop the flush cycle.

Dispose the antifreeze in an environmentally safe way according to local waste disposal regulations.

5.

The machine is now ready for scrubbing.

72

Home Find... Go To..

5680 330459 (10--08)

SPECIFICATIONS

GENERAL MACHINE DIMENSIONS/CAPACITIES

Item

Length with cylindrical scrub head

Length with 700 mm disk scrub head

Length with 800 mm disk scrub head

Length with 900 mm disk scrub head

Width (less squeegee and scrub head)

Height

Disk brush diameter for 700 mm scrub head

Disk brush diameter for 800 mm scrub head

Disk brush diameter for 900 mm scrub head

Cylindrical brush diameter

Cylindrical brush length for 700 mm scrub head

Cylindrical brush length for 800 mm scrub head

Cylindrical brush length for 900 mm scrub head

Squeegee width for 700 mm scrub head

Squeegee width for 800 mm scrub head

Squeegee width for 900 mm scrub head

Scrubbing path width for 700 mm scrub head

Scrubbing path width for 800 mm scrub head

Scrubbing path width for 900 mm scrub head

Solution tank capacity (recommended usage)

Solution tank capacity (maximum)

Recovery tank capacity to full sensor

Recovery tank capacity to top of tank

Transaxle 90 weight gear lubricant capacity

GVWR

800 mm

900 mm

114 L

133 L

114 L

152 L

1,42 L

690 kg

Dimension/capacity

1.600 mm

1.625 mm

1.660 mm

1.690 mm

720 mm

1.090 mm

355 mm

405 mm

455 mm

150 mm

695 mm

795 mm

900 mm

950 mm

1.065 mm

1.155 mm

700 mm

SPECIFICATIONS

5680 330459 (11--05)

Home Find... Go To..

73

SPECIFICATIONS

FaST SYSTEM (OPTION)

Item

Solution pump

Solution flow rate

Detergent pump

Concentrate flow rate

Concentrate to water dilution ratio

Air pump

Air pump flow rate

Measure

36 Volt DC, 5A, 5,7 LPM (1,5 GPM) open flow,

45 psi bypass setting

0,83 LPM (0,22 GPM)

36 Volt DC

0,9 CC/Minute (0,03 Ounces/Minute)

1:1000

24 Volt DC, 0,6 Maximum Amp draw

8,7 LPM (0,3 CFM) open flow

ec- H2O SYSTEM (OPTION)

Item

Solution pump

Solution flow rate* -- Disk 700 mm

Solution flow rate* -- Disk 800 mm

Solution flow rate* -- Disk 900 mm

Solution flow rate* -- Cylindrical 700 mm

Solution flow rate* -- Cylindrical 800 mm

Solution flow rate* -- Cylindrical 900 mm

Measure

36 Volt DC, 5A, 5,7 LPM (1,5 GPM) open flow,

45 psi bypass setting

0,83 L/min / 0,22 gpm (standard)

1,25 L/min / 0,33 gpm (optional)

1,66 L/min / 0,44 gpm (optional)

0,83 L/min / 0,22 gpm (standard)

1,25 L/min / 0,33 gpm (optional)

1,66 L/min / 0,44 gpm (optional)

1,10 L/min / 0,30 gpm (standard)

1,66 L/min / 0,44 gpm (optional)

2,00 L/min / 0,53 gpm (optional)

1,25 L/min / 0,33 gpm (standard)

1,66 L/min / 0,44 gpm (optional)

1,25 L/min / 0,33 gpm (standard)

1,66 L/min / 0,44 gpm (optional)

1,66 L/min / 0,44 gpm (standard)

2,00 L/min / 0,53 gpm (optional)

* If the optional solution flow rates are required, contact an Authorized Service Center.

GENERAL MACHINE PERFORMANCE

Item

Aisle turnaround width with 700 mm scrub head

Aisle turnaround width with 800 mm scrub head

Aisle turnaround width with 900 mm scrub head

Maximum rated climb and descent angle with empty tanks

Maximum rated climb and descent angle with full tanks

Measure

1.685 mm

1.700 mm

1.715 mm

8_

6_

74

5680 330459 (10--08)

Home Find... Go To..

SPECIFICATIONS

POWER TYPE

Type

Batteries

Type

Electric Motors

Type

Chargers (Smart)

6

Quantity

6

Use

Scrub brush (disk)

Scrub brush (cylindrical)

Vacuum fan

Propelling

Volts

6

6

VDC

36

36 amp

20

30

Hz

60

60

VDC

36

36

36

36

Ah Rating

235 @ 20 hr rate

335 @ 20 hr rate

Kw

0,56

0,56

0,63

0,37

Weight

30 kg

47 kg

Phase

1

1

VAC

115

115

TIRES

Location

Front (2)

Rear, casters (2)

Type

Foam filled, non--marking

Solid, non-marking

Size

4,10/3,5 -- 6

127 mm x 35 mm

5680 330459 (9--02)

Home Find... Go To..

75

SPECIFICATIONS

1.625 mm

1.660 mm

1.690 mm

950 mm

1.065 mm

1.155 mm

1.090 mm

MACHINE DIMENSIONS

720 mm

353416

76

Home Find... Go To..

5680 330459 (9--02)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement