advertisement
QuickSpecs
Overview
HP ProLiant DL360 Generation 5
1. Low-profile x8 PCI-Express slot
2. Eight PC2-5300 FB-DIMMs (DDR2 667) slots
3. Up to two Intel Quad-Core or Dual-Core Xeon™ processors
4. Slide-out System Insight Display
5. Slimline removable media bay
6. Up to six SAS/SATA hot plug drive bays
7. Removable fans for easy serviceability
8. Choice of Smart Array P400i Controller or Smart Array
E200i Controller
9. Redundant Hot Plug Power Supplies (upgradeable option)
10. Full length/height x8 PCI-Express Slot (optional PCI-X)
What's New
New Quad-Core Intel Xeon 5300 sequence processor models are now available (E5320, E5310 both with 8M
(2x4MB) L2 Cache, and 1066 FSB
At A Glance
Combining concentrated 1U compute power, integrated Lights-Out management, and essential fault tolerance, the DL360 is optimized for space constrained installations. Dual-core Xeon processors, DDR2 Fully Buffered DIMMs, Serial Attached
SCSI (SAS) and PCI Express technology provide a high performance system ideal for the full range of scale out applications. What's more, the HP ProLiant DL360 G5 steps up the fault tolerant in an ultra dense platform with redundant power, redundant fans, mirrored memory or online spare memory, embedded RAID capability, and full-featured remote
Lights-Out management.
Processors:
Up to (2) Quad-Core or Dual-Core Intel® Xeon® processor 5000 sequence
Intel 5000P chipset supporting up to a 1333MHz front-side bus
Memory:
Up to 32 GB of memory, supported by (8) slots of PC2-5300 Fully Buffered DIMMs (DDR2-667); 4:1 interleaving; memory mirroring; online spare
Storage Controller:
Performance Models: HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6) (512MB BBWC optional)
Base Models: HP Smart Array P400i/256MB Controller (RAID 0/1/1+0/5) (512MB BBWC optional)
Entry Models: HP Smart Array E200i/64MB Controller (RAID 0/1/1+0) (128MB BBWC optional)
Internal Drive Support:
Up to (6) small form factor (SFF) hot-plug drive bays
Slimline media bay supporting DVD, CD or Floppy drive
Network Controller:
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 1
QuickSpecs
HP ProLiant DL360 Generation 5
Overview
Embedded NC373i Multifunction Gigabit Server Adapters with TCP/IP Offload Engine, including support for
Accelerated iSCSI and RDMA through optional ProLiant Essentials Licensing Kits
Expansion Slots:
Two PCI-Express expansion slots: (1) full-length, full-height slot; (1) low-profile slot
Front or rear accessible video port
USB 2.0 Ports:
4 Total: (1) front, (1) internal and (2) rear accessible ports
Redundancy:
Multiple layers of fault tolerance through critical component redundancy (power supply and fan redundancy), mirrored memory, embedded RAID capability, and full-featured remote Lights-Out management
Management:
New Integrated Lights-Out 2 featuring Integrated Remote Console with KVM over IP performance over shared network access
HP Power Meter and Power Regulator for ProLiant, delivering integrated power monitoring and server level, policy based power management with industry leading energy efficiency and savings on system power and cooling costs
Convenient slide-out Systems Insight Display for quick and easy front view server diagnostics
ProLiant Essential Foundation Pack standard, including HP Systems Insight Manager, SmartStart, SmartStart
Scripting Toolkit, Subscriber's Choice and ROM Based Setup Utility (RBSU)
Automatic Server Recovery (ASR), ROM Based Setup Utility (RBSU), HP System Insight Manager, Status
LEDs including system health, UID, and SmartStart
Form Factor:
1U Rack form factor (1.75"), less than 28 inches (70.5 cm) deep
Deployment/Serviceability:
Sliding rails for in rack servicing ship standard; optional ambidextrous cable management arm
Warranty:
Protected by HP Services and a worldwide network of resellers and service providers. Three-year next business day, on-site limited global warranty. Certain restrictions and exclusions apply. Pre-failure notification on processors, memory, and SAS hard drives. SATA hard drives have a one-year warranty.
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 2
QuickSpecs
Standard Features
HP ProLiant DL360 Generation 5
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information –
Factory Integrated Models" section.
Processor
One of the following depending on Model
Quad-Core Intel Xeon Processor E5320 (1.86 GHz 80 Watts, 1066 Front Side Bus (FSB))
Quad-Core Intel Xeon Processor E5310 (1.60 GHz 80 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5160 (3.0 GHz, 80 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5150 (2.67 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5148 (2.33 GHz, 40 Watts, 1333 FSB, Low Voltage)
Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5130 (2.0 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5120 (1.86 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5110 (1.6 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5080 (3.73GHz, 130 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5060 (3.2GHz, 130 Watts, 1066 FSB)
NOTE: Up to 2 processors supported. Performance configurations include two processors.
NOTE: Intel 5300 sequence processors are 64-bit, Quad-Core, and supports Intel VT technology.
Intel 5100/5000 sequence processors are 64-bit, Dual-Core, and supports Intel VT technology.
Cache Memory
One of the following depending on Model
8MB (2 x 4MB) Level 2 cache (5300 sequence)
4MB (1 x 4MB) Level 2 cache (5100 sequence)
4MB (2 x 2MB) Level 2 cache (5000 sequence)
Upgradeability
Chipset
Upgradeable to quad or dual processing
Future upgradeable to Xeon Series 5300 Quad-Core, or 5100 Dual-Core processors
Intel 5000P chipset
NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/ .
Memory Protection &
Functionality
Advanced ECC (multi-bit error protection), Online Spare, Mirroring
4-way interleaving
Memory
Type
Standard (Entry or Base
Models)
Standard (Performance
Models)
PC2-5300 Fully Buffered DIMMs (DDR2-667)
1 GB (2 x 512 MB)
2 GB (2 x 1 GB)
Maximum 32 GB (8 x 4 GB)
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at
667 MHz and in systems with a FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533 MHz.
Network Controller
Embedded NC373i Multifunction Gigabit Server Adapters with TCP/IP Offload Engine, including support for Accelerated iSCSI and RDMA through optional ProLiant Essentials Licensing Kits
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 3
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
Expansion Slots Slot Number Bus Speed
1
2 x8 PCI Express x8 PCI Express
Bus
Number
*
11
19
Device
Number
0
0
**
Hot Plug
no no
PCI Voltage
N/A
N/A
2 64-bit/133MHz
PCI-X (option)
16 1 no 3.3 Volt
*NOTE: Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
**NOTE: Slots are enumerated differently based on OS. Microsoft OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus).
Manageability
Integrated Lights Out 2 (iLO 2) Standard Management:
Virtual Text Remote Console
Virtual Power Button Control
Integrated Remote Console
Dedicated & full function shared network connectivity
Embedded system health
Browser, command line and scripted access
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) and Secure Shell security (SSH)
OS independent hardware health status
IML and iLO Event Logging
Support for 12 user accounts with customizable access privilege
Storage Controller
One of the following depending on Model
Performance Models: HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6)
Available upgrades: 512MB memory battery-backed write cache
(BBWC) module for RAID 0/1/1+0/5/6.
Base Models:
Entry Models:
HP Smart Array P400i/256MB Controller (RAID 0/1/1+0/5)
Available upgrades: 512MB memory battery for battery-backed write cache (BBWC) module for RAID 0/1/1+0/5/6, or battery-backed write cache for RAID 0/1/1+0/5/6.
HP Smart Array E200i/64MB Controller (RAID 0/1/1+0)
Available upgrades: 128MB memory battery for battery-backed write cache (BBWC) module for RAID 0/1/1+0/5.
Storage
Maximum Internal
Storage Type
Optical Drives
(Slimline Drive bay)
Drive Bays
Hot Plug Serial Attached
SCSI (SAS)
Hot Plug Serial ATA
(SATA)
Optional DVD-ROM, DVD/CD-RW Combo (standard in performance models), DVD-RW, or Slimline floppy drive
Up to 6 Small Form Factor bays total
NOTE: 4 bays active in most models. Smart Array P400i controller and
Mini-SAS storage cable (P/N 399546-B21) required for activation of 5th and 6th drive bays.
876GB SAS
360GB SATA
6 x 146GB SAS
6 x 60GB SATA
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 4
QuickSpecs
Standard Features
Interfaces
Keyboard
Mouse
Serial
Video
USB 2.0 Ports
HP ProLiant DL360 Generation 5
1
1
1
2
1
1
4 total: 2 rear, 1 front, 1 internal
NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usbsupport.html
.
Network RJ-45 iLO 2 remote management port
Graphics
Form Factor
Integrated ATI ES1000 1280 x 1024 x 16M color (32MB video standard)
Rack (1U), (1.75 in/4.45 cm); 27.75 inch depth (70.5cm)
ProLiant Essentials
Foundation Pack
Software
HP Systems Insight
Manager
SmartStart
Insight Management
Agents
HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible environment to centrally manage servers, storage and other infrastructure devices across multiple operating system platforms.
Through a single management view, HP SIM provides core management services that include device discovery and identification, event views, health monitoring, inventory data collection, software version control and reporting. HP SIM is built on industry standards and is extensible with value-added ProLiant Essentials, Integrity Essentials and Storage Essentials software to meet individual management needs.
For more details on HP SIM visit http://www.hp.com/go/hpsim .
HP SIM provides organizations with the following benefits:
Simplifies and consolidates infrastructure lifecycle management using task and query based functionality
Provides the foundation for infrastructure automation and virtualization
Enables IT management based on business processes not hardware platforms
Lowers infrastructure maintenance cost and frees resources for innovation
Maximizes resource utilization with virtualization technologies
Provides a central point of integration between infrastructure and
Enterprise management tools such as HP OpenView
SmartStart is a tool that simplifies server setup, providing a rapid way to deploy reliable and consistent server configurations. For more information, please visit the SmartStart Web site at http://www.hp.com/servers/smartstart .
SmartStart version supported (minimum): SmartStart 7.51.
Insight Management Agents should be installed on all HP servers to present system instrumentation, health and configuration information into HP Systems Insight Manager and the HP System Management
Homepage. The HP System Management Homepage aggregates systems data from Insight Management Agents and other HP management tools, providing a consolidated browser-based interface
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 5
QuickSpecs
Standard Features
HP ProLiant DL360 Generation 5
for managing individual servers,
Subscriber's Choice
ROMPaq, support software, and configuration utilities
Insight Diagnostics
Optional ProLiant
Essentials Value Packs
Insight Management Agents and The HP System Management
Homepage are included on ProLiant Support Packs, and can also be installed using the server profiles provided with the ProLiant Essentials
Rapid Deployment Pack. For additional information about the
Management Agents and the HP System Management Homepage please visit the management Web site at http://www.hp.com/servers/manage .
Subscriber's Choice Driver and Support Alerts/Notifications is a webbased email subscription service that provides automatic delivery of software and driver change notifications for ProLiant products. Sign up at http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options available in SmartStart or downloadable from Software and Drivers download pages: http://www.hp.com/go/support
The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in
SmartStart.
Optional software offerings that selectively extend the functionality of an
Adaptive Infrastructure to address specific business problems and needs:
Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers. RDP includes the
ProLiant Integration Module featuring ProLiant server preconfigured events for OS installation, and optimized software drivers, firmware and management agents. Every RDP disc includes 7-day, 10-node trial licenses for evaluation purposes.
RDP requires a license for each server deployed and is available for purchase with HP servers. For more information, visit: http://www.hp.com/servers/rdp .
Workload Management Pack – provides easier management of complex environments, improving overall server utilization and enabling Windows® 2000 customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server.
Performance Management Pack – a performance management solution that identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources.
Intelligent Networking Pack – detects and analyzes network bottlenecks or broken network linkages and steers traffic to the optimum route based on network conditions, plus it provides an extra layer of protection. The virus throttle feature of the solution slows the propagation of fast spreading virus
Vulnerability and Patch Management Pack – identifies and remediates software security vulnerabilities due to missing patches as well operating system configurations that can be exploited by viruses, worms, and other blended threats
Virtual Machine Management Pack – provides central management and control of virtual machines from Microsoft and
VMware. Integrated approach provides the ability to manage both physical and virtual resources from a single management
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 6
QuickSpecs
Standard Features
HP ProLiant DL360 Generation 5
Optional Remote
Management Packs console.
Server Migration Pack – The Server Migration Pack automates the manual processes required for migrating servers between physical or virtual platforms (P2V, V2P, and V2V).
Server Migration Pack – P2P Edition: Upgrading or replacing your existing server? Effortlessly transition to new servers with automated, accurate and affordable migration of OS, application and data.
Accelerated iSCSI Pack - enables the embedded Multifunction network controller to serve as both a NIC and an iSCSI HBA providing access to SAN storage over the same connection used for networking. Processing of the protocol stack is offloaded to the NIC reducing CPU utilization and greatly improving the speed with which the requests are processed and sent to the network.
Remote Directory Memory Access (RDMA) Pack for Embedded
Multifunction Gigabit Server Adapters – provides direct and faster communication between application buffers in separate servers for tasks that involves moving large amounts of data, such as network backups, database read/write, and high performance computing.
Integrated Lights-Out Advanced Pack - upgrades the iLO 2 processor with comprehensive remote control including Virtual
KVM graphical console, virtual media, power management and enterprise security.
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials
Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following
URL: http://www.hp.com/servers/proliantessential .
Industry Standard
Compliance
ACPI 1.0b Compliant
PCI 2.2 Compliant
WOL Support
Microsoft® Logo certifications
PXE Support
USB 1.1 and 2.0 Compliant
Remote Management
Integrated Lights Out 2 (iLO2) Standard Management:
Virtual Text Remote Console
Virtual Power Button Control
Integrated Remote Console
Dedicated & full function shared network connectivity
Embedded system health
Browser, command line and scripted access
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) and Secure Shell security (SSH)
OS independent hardware health status
IML and iLO Event Logging
Support for 12 user accounts with customizable access privilege
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 7
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
Intelligent
Manageability
HP Systems Insight Manager
SmartStart
ROM-Based Setup Utility (RBSU)
Remote-Flash Redundant ROM
Integrated Management Log (IML)
Server Health logging
Automatic Server Recovery-2 (ASR-2)
System Insight Display (SID)
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Hot Spare Boot
NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will automatically reboot and use the remaining good processor(s).
Power Down Utility
Pre-Failure Warranty (covers processors, as well as SAS hard drives and memory)
Security
Power-on password
Keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Removable CD and Diskette Drive Assembly
Serial interface control
Administrator's password
Disk configuration lock
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting iLO Advance Pack supports directory services integration and two-factor authentication
Server Power Cords
High voltage power cord ships standard with all part numbers.
UPS Power Cord
Matrix
Please see the UPS Power Cord Matrix for cable descriptions, requirements, and specifications for UPS units: ftp://ftp.compaq.com/pub/products/servers/proliantstorage/power-protection/powercordmatrix.pdf
.
Power Supply
700W, Optional (1+ 1 redundant) power supply
NOTE: PN 399542-B21 contains the optional power supply and an IEC power cable only; purchase if connecting to PDU/UPS that supports IEC cables.
System Fans
Required Cabling
9 fans ship standard; N+1 fan redundancy standard
For required cabling information, refer to the Web site at http://h18000.www1.hp.com/products/servers/proliantdl360/ .
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 8
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
OS Support
Microsoft Windows 2000 Server
Microsoft Windows Server 2003
Novell NetWare
Linux (Red Hat, SuSE)
Solaris 10 32/64-bit
VMware Virtualization Software
NOTE: SAS and SATA models may have different OS support. Please see OS Support Matrix.
NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix page at: http://www.hp.com/go/supportos .
NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html
NOTE: For a listing of the latest drivers available for the HP ProLiant DL360, please see: http://h18023.www1.hp.com/support/files/server/us/index.html
.
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux
Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html
.
NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the
VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html
.
Rack Airflow
Requirements
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/proliantdl360/index.html
.
Telco Rack Support
HP ProLiant DL360 G5 Telco Rack Kit:
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions ( http://www.racksolutions.com/hp/ )
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 9
QuickSpecs
HP ProLiant DL360 Generation 5
Standard Features
Factory Express
Portfolio for Servers and Storage
HP Factory Express offers configuration, customization, integration and deployment services for
HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP
BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express .
HP Enterprise
Configurator
The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's
Customer Business Center or an Authorized Partner for assistance.
http://www.hp.com/products/configurator
HP ProLiant Smart
Buys
The HP Smart Buy program offers mainstream business solutions at competitive prices with excellent availability and superior HP quality. It offers a wide range of industry-leading HP products at compelling prices, allowing you to receive richer configurations with additional options.
NOTE: For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf
Service and Support
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care
Pack services or customized service agreements.
NOTE: Server Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack.
HP services provide continuous care and support expertise with committed response designed to meet your IT and business needs.
To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime.
Enhanced Care – Minimum recommended service support offer designed to ensure customers
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 10
QuickSpecs
Standard Features
HP ProLiant DL360 Generation 5
have access to expert assistance, whenever they need it.
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
Continuance Care – Recommended service delivering cost-effective support options designed to extend HP Services committed response and guaranteed fix times, designed to speed problem identification and resolution.
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years
Total Care – Highest HP Support service level recommend to help increase IT performance and availability with comprehensive, integrated hardware and software services
Support Plus 24 – Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays
Deployment Services – HP Installation and Start Up services designed to take time, risk, and worry out of the deployment of ProLiant servers – and free customers IT support staff to focus on what they do best, their business.
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl.
HP holidays
NOTE: For a complete listing of service offerings and information visit: http://www.hp.com/services/proliantservices http://www.hp.com/go/proliant/carepack
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 11
QuickSpecs
Models
HP ProLiant DL360 Generation 5
NOTE: For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf
.
Models
HP DL360 G5
Performance Models
Dual-Core Models
DL360R05 5160 2GB
416566-001
DL360R05 5150 2GB
416564-001
Processor(s)
Two of the following depending on Model
Cache Memory
Memory
Network Controller
Storage Controller
(2) Dual-Core Intel Xeon 5160 Processor (3.00 GHz, 80 Watts, 1333
FSB)
(2) Dual-Core Intel Xeon 5150 Processor (2.66 GHz, 65 Watts, 1333
FSB)
4MB (1 x 4MB) Level 2 cache - Intel Xeon Processor 5100 Sequence
2 GB (2 x 1 GB) Standard; PC2-5300 Fully Buffered DIMMs (DDR2-
667)
Embedded NC373i Multifunction Gigabit Server Adapters
Hard Drive
HP Smart Array P400i/256MB BBWC Controller (RAID 0/1/1+0/5/6)
512MB BBWC optional upgrade
No drives included; (6) drive bays active
Internal Storage
Optical Drive
PCI-Express Slots
Power Supplies
876GB SAS; 360GB SATA
Slimline DVD/CD-RW Combo drive
1 full-length x8 PCI-Express slot
1 low-profile x8 PCI-Express slot
(2) 700W power supplies, redundant
Fans
Form Factor
9 total, redundancy standard
Rack (1U), (1.75 in/4.45 cm); 27.75 inch depth (70.5cm)
HP DL360 G5 Base
Models
Quad-Core Models
DL360R05 E5320 1GB
438313-001
Dual-Core Models
DL360R05 5160 1GB
416565-001
DL360R05 5150 1GB
416563-001
DL360R05 5140 1GB
416562-001
DL360R05 5060 1GB
399519-001
Processor(s)
One of the following depending on Model
Cache Memory
One of the following depending on Model
Memory
Network Controller
Storage Controller
Hard Drive
Internal Storage
Optical Drive
PCI-Express Slots
Power Supply
(1) Quad-Core Intel Xeon E5320 Processor (1.86 GHz, 80 Watts, 1066
FSB)
(1) Dual-Core Intel Xeon 5160 Processor (3.00 GHz, 80 Watts, 1333
FSB)
(1) Dual-Core Intel Xeon 5150 Processor (2.66 GHz, 65 Watts, 1333
FSB)
(1) Dual-Core Intel Xeon 5140 Processor (2.33 GHz, 65 Watts, 1333
FSB)
(1) Dual-Core Intel Xeon 5060 Processor (3.20 GHz, 130 Watts, 1066
FSB)
8MB (2 x 4MB) Level 2 cache - Intel Xeon Processor 5300 Sequence
4MB (1 x 4MB) Level 2 cache - Intel Xeon Processor 5100 Sequence
4MB (2 x 2MB) Level 2 cache - Intel Xeon Processor 5000 Sequence
1 GB (2 x 512 MB) Standard; PC2-5300 Fully Buffered DIMMs (DDR2-
667)
Embedded NC373i Multifunction Gigabit Server Adapters
HP Smart Array P400i/256MB Controller (RAID 0/1/1+0/5) 512MB
BBWC or BBWC optional upgrades
No drives included; (4) drive bays active.
(6) bays supported with optional storage cable
(PN 399546-B21)
876GB SAS; 360GB SATA
Optional DVD, DVD/CD-RW, or Floppy
1 full-length x8 PCI-Express slot
1 low-profile x8 PCI-Express slot
(1) 700W power supply, redundant optional
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 12
QuickSpecs
Models
Fans
Form Factor
HP ProLiant DL360 Generation 5
9 total, redundancy standard
Rack (1U), (1.75 in/4.45 cm); 27.75 inch depth (70.5cm)
HP DL360 G5 Entry
Models
Quad-Core Models
DL360R05 E5310 1GB
438312-001
DL360R05 5130 1GB
416561-001
DL360R05 5120 1GB
416560-001
DL360R05 5110 1GB
416559-001
Processor(s)
One of the following depending on Model
Cache Memory
Memory
Network Controller
Storage Controller
Hard Drives
Internal Storage
Optical Drive
PCI-Express Slots
Power Supply
Fans
Form Factor
(1) Quad-Core Intel Xeon Processor E5310 (1.60 GHz 80 Watts, 1066
FSB)
(1) Dual-Core Intel Xeon 5130 Processor (2.00 GHz, 65 Watts, 1333
FSB)
(1) Dual-Core Intel Xeon 5120 Processor (1.86 GHz, 65 Watts, 1066
FSB)
(1) Dual-Core Intel Xeon 5110 Processor (1.6 GHz, 65 Watts, 1066
FSB)
8MB (2x4MB) Level 2 cache- Intel Xeon Processor 5300 Sequence
4MB (1 x 4MB) Level 2 cache - Intel Xeon Processor 5100 Sequence
1 GB (2 x 512 MB) Standard; PC2-5300 Fully Buffered DIMMs (DDR2-
667)
Embedded NC373i Multifunction Gigabit Server Adapters
HP Smart Array E200i/64MB Controller (RAID 0/1/1+0), 256MB BBWC optional upgrade
No drives included; (4) drive bays active
876GB SAS; 360GB SATA
Optional DVD, DVD/CD-RW, or Floppy
1 full-length x8 PCI-Express slot
1 low-profile x8 PCI-Express slot
(1) 700W power supply, redundant optional
9 total, N+1 redundancy standard
Rack (1U), (1.75 in/4.45 cm); 27.75 inch depth (70.5cm)
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 13
QuickSpecs
Configuration Information - Factory Integrated Models
HP ProLiant DL360 Generation 5
NOTE: HP does not allow factory integration of options into standard models listed above.
Configure-to-order servers must start with a CTO Chassis.
NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
NOTE: FIO indicates that this option only available as a Factory Installable Option.
Step 1: Base Configuration (choose one of the following configurable models)
Models
HP ProLiant DL360 G5 Rack CTO Chassis
Factory Integrated Model ships with:
399524-B21
Embedded NC373i Multifunction Gigabit Server Adapter
Integrated Lights-Out 2 (iLO 2) embedded
1 full-length and 1 low-profile x8 PCI-Express slots
9 fans; N+1 fan redundancy
(1) 700W power supply, redundant optional
Rack (1U), (1.75 in/4.45 cm)
Step 2: Choose Required Options (only one of the following from each list unless otherwise noted)
Processors
Quad-Core Intel Xeon Processor E5320 – 1.86GHz, 80 Watts, 1066 FSB
Quad-Core Intel Xeon Processor E5310 – 1.60GHz, 80 Watts, 1066 FSB
435950-L21
438314-L21
Base Memory
Storage Controllers
Dual-Core Intel Xeon Processor 5160 – 3.00 GHz, 80 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5150 – 2.66 GHz, 65 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5148 – 2.4 GHz, 40 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5140 – 2.33 GHz, 65 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5130 – 2.00 GHz, 65 Watts, 1333 FSB
Dual-Core Intel Xeon Processor 5120 – 1.86 GHz, 65 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5110 – 1.60 GHz, 65 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5080 – 3.73 GHz, 130 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5060 – 3.20 GHz, 130 Watts, 1066 FSB
Dual-Core Intel Xeon Processor 5050 – 3.00 GHz, 95 Watts, 667 FSB
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
Smart Array E200i controller for DL360 G5
NOTE: If selected, must choose one of the two cache modules below.
HP Smart Array E200 64MB FIO Cache
NOTE: Supports Smart Array E200 Controller only.
128MB Battery Backed Write Cache Enabler Option Kit
NOTE: Supports Smart Array E200i Controller.
Smart Array P400i controller for DL360 G5
NOTE: If selected, must choose one of the two cache modules below.
HP Smart Array P400 256MB Cache FIO
NOTE: Supports Smart Array P400 Controller and Smart Array P400i Controller only.
512MB Battery-backed cache upgrade
NOTE: Supports Smart Array P400 Controller and Smart Array P400i Controller only.
Battery-backed write cache upgrade (battery only)
NOTE: For Smart Array P400 Controller and Smart Array P400i Controller only.
416579-L21
416577-L21
416575-L21
416573-L21
416571-L21
416569-L21
416567-L21
399540-L21
399536-L21
399532-L21
397409-B21
397411-B21
397413-B21
397415-B21
399548-B21
405102-B21
346914-B21
413741-B21
405139-B21
405148-B21
383280-B21
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 14
QuickSpecs
HP ProLiant DL360 Generation 5
Configuration Information - Factory Integrated Models
HP Smart Array P600/256 BBWC Controller
NOTE: Requires PCI-X Riser option (PN 405154-B21).
NOTE: Requires HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (PN 411100-
B21).
337972-B21
Step 3: Choose Additional Factory Integratable Options
Performance Packs
The HP ProLiant DL360 G5 performance packs are necessary to configure a HP
ProLiant DL360 G5 Performance Model. HP ProLiant DL360 G5 Performance model includes the latest performance technologies and enterprise class availability features pre-installed for convenience and value. The performance pack includes a 2nd processor, redundant power supplies, Smart Array P400i
Controller with 256MB of BBWC, and storage cable to enable the all 6 disk drive bays.
NOTE: 331903-B21 Slimline CD-RW/DVD-ROM Combo Drive Option Kit should also be selected along with the Performance Pack skus below to achieve parity to the HP ProLiant DL360 G5 Performance Models.
HP DL360G5 X5160 HPM FIO Perf Pack
HP DL360G5 X5150 HPM FIO Perf Pack
430107-B21
431883-B21
Step 4: Choose Additional Options for Factory Integration
NOTE: For additional options, please refer to the "Options" section below.
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 15
QuickSpecs
Options
HP ProLiant DL360 Generation 5
NOTE: Some options may not be factory integratable. Contact your local sales representative for additional information.
HP ProLiant DL360
G5 Unique Options
Quad-Core Intel Xeon Processor E5320 (1.86 GHz, 80 Watts, 1066 FSB)
Quad-Core Intel Xeon Processor E5310 (1.60 GHz, 80 Watts, 1066 FSB)
435950-B21
438314-B21
Dual-Core Intel Xeon Processor 5160 (3.00 GHz, 80 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5150 (2.66 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5148 (2.4 GHz, 40 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 65 Watts, 1333 FSB)
416579-B21
416577-B21
416575-B21
416573-B21
Dual-Core Intel Xeon Processor 5130 (2.00 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5120 (1.86 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5110 (1.60 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5080 (3.73 GHz, 130 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5060 (3.2 GHz, 130 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5050 (3.0 GHz, 95 Watts, 667 FSB)
PCI-X Riser option
NOTE: To convert full-length PCI-Express slot to PCI-X slot.
Ambidextrous cable management arm
NOTE: Package contains two cable management arms
Fixed Cord Extension Bars for 1U servers (2 PDU sticks per kit)
700W HP redundant power supply with IEC cord only
416571-B21
416569-B21
416567-B21
399540-B21
399536-B21
399532-B21
405154-B21
365403-B21
351655-B21
399542-B21
ProLiant Essentials
Value Pack Software
ProLiant Essentials Accelerated iSCSI Pack
ProLiant Essentials Accelerated iSCSI Pack, Single License
NOTE: For additional Accelerated iSCSI Pack License Kits, please see the
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12466_na/12466_na.HTML
ProLiant Essentials Intelligent Networking Pack
ProLiant Essentials Intelligent Networking Pack – Windows Edition, Single
Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.HTML
ProLiant Essentials Intelligent Networking Pack – Linux Edition, Single Server
License
NOTE: For additional ProLiant Intelligent Networking Pack – Linux License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_na/12327_na.HTML
ProLiant Essentials Performance Management Pack
ProLiant Essentials Performance Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation.
NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp .
NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_na/11925_na.HTML
HP ProLiant Essentials Remote Directory Memory Access (RDMA) Pack
407484-B22
436225-B21
436229-B21
306696-B21
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 16
QuickSpecs
Options
HP ProLiant DL360 Generation 5
HP ProLiant Essentials RDMA Pack for Embedded Multifunction Gigabit Server
Adapters, 1 License
HP ProLiant Essentials RDMA Pack for Standup Multifunction Gigabit Server
Adapters, 1 License
NOTE: For additional ProLiant Essentials RDM Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12573_na/12573_na.HTML
ProLiant Essentials Rapid Deployment Pack
Rapid Deployment Pack, Single-Server License
NOTE: This license allows 1 server to be deployed and managed via RDP.
NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.HTML
ProLiant Essentials Workload Management Pack
ProLiant Essentials Workload Management Pack, Single Server License
NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_na/11452_na.HTML
ProLiant Essentials Virtualization Management Software
ProLiant Essentials Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
ProLiant Essentials Server Migration Pack, Single-Migration License
NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation.
NOTE: For additional ProLiant Essentials Virtualization Management Software
License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.HTML
NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005.
ProLiant Essentials Physical to ProLiant Edition
ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition, Single-
Migration License
NOTE: For additional ProLiant Essentials Server Migration License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12467_na/12467_na.HTML
ProLiant Essentials Vulnerability and Patch Management Pack
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server
License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
NOTE: For additional ProLiant Vulnerability and Patch Management Pack
License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_na/12111_na.HTML
NOTE: Flexible and volume quantity license kits are available for ProLiant
Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials .
407478-B22
407481-B22
267196-B21
303284-B21
435661-B21
435663-B21
412978-B21
371645-B21
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 17
QuickSpecs
Options
HP ProLiant DL360 Generation 5
Remote Management Integrated Lights-Out Advanced Pack
ProLiant Essentials Integrated Lights-Out Advanced Pack, 1 server
Featuring: Sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites.
NOTE: For additional Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11052_na/11052_na.HTML
263825-B21
ProLiant Software
Maintenance
Subscription
ProLiant Software Maintenance Subscription
ProLiant Software Maintenance Single Release
ProLiant Foundation Pack Single Release
NOTE: Please see the SmartStart QuickSpecs for additional information regarding the subscription purchase: http://h18000.www1.hp.com/products/quickspecs/North America/11073.html
355060-B21
356573-B21
356604-B21
Processor
Memory (DIMMs)
Quad-Core Intel Xeon Processor E5320 (1.86 GHz, 80 Watts, 1066 FSB)
Quad-Core Intel Xeon Processor E5310 (1.60 GHz, 80 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5160 (3.00 GHz, 80 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5150 (2.66 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5148 (2.4 GHz, 40 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5130 (2.00 GHz, 65 Watts, 1333 FSB)
Dual-Core Intel Xeon Processor 5120 (1.86 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5110 (1.60 GHz, 65 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5080 (3.73 GHz, 130 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5060 (3.2 GHz, 130 Watts, 1066 FSB)
Dual-Core Intel Xeon Processor 5050 (3.0 GHz, 95 Watts, 667 FSB)
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
435950-B21
438314-B21
416579-B21
416577-B21
416575-B21
416573-B21
416571-B21
416569-B21
416567-B21
399540-B21
399536-B21
399532-B21
397409-B21
397411-B21
397413-B21
397415-B21
Optical Drives
Diskette Drive
Slimline CD-RW/DVD-ROM Combo Option Kit
Slimline DVD-ROM Drive (8X/24X) Option Kit
HP DVD+R/RW 8X Slim
Slimline CD-ROM Drive 24X
Slimline Ejectable Floppy drive
331903-B21
264007-B21
383975-B21
356963-B21
390164-B21
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 18
QuickSpecs
Options
Hard Drives
HP ProLiant DL360 Generation 5
Serial Attached SCSI (SAS) SFF Hot Plug
HP 36GB 3G SAS 10K SFF SP HDD
HP 72GB 3G SAS 10K SFF SP HDD
HP 146GB 3G SAS 10K SFF SP HDD
NOTE: Please see the SAS Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.HTML
SFF SATA Hot Plug
HP 60GB 1.5G SATA 5.4K SFF HDD
NOTE: SATA drives have a 1 year warranty. Please see the SATA Hard Drive
QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/12091_na/12091_na.HTML
375859-B21
375861-B21
431958-B21
379306-B21
Storage Controllers SAS Controllers
Smart Array E200i Controller
128-MB Battery-Backed Write Cache (BBWC)
NOTE: Supports Smart Array E200i Controller only.
Smart Array P400i Controller
HP Smart Array P400i/256MB Controller
Battery-backed write cache upgrade
NOTE: For Smart Array P400 Controller and Smart Array P400i Controller only.
512MB Battery-backed cache upgrade
NOTE: For Smart Array P400 Controller and Smart Array P400i Controller only.
Smart Array P600 Controller
HP Smart Array P600/256 BBWC Controller
NOTE: Requires DL360 G5 PCI-X conversion kit (PN 405154-B21).
512 MB Battery-Backed Cache Upgrade
NOTE: This 512-MB Battery-Backed Cache Module upgrade kit supports the
Smart Array P600 Controller and the Smart Array 6400 series Controller.
Smart Array P800 Controller
HP Smart Array P800/512 BBWC Controller
NOTE: Please see the following Controller QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12460_na/12460_na.HTML
(Smart Array E200 Controller) http://h18000.www1.hp.com/products/quickspecs/12400_na/12400_na.HTML
(Smart Array P400 Controller) http://h18000.www1.hp.com/products/quickspecs/12247_na/12247_na.HTML
(Smart Array P600 Controller) http://h18000.www1.hp.com/products/quickspecs/12616_na/12616_na.HTML
(Smart Array P800 Controller)
SAS HBA
HP 8 Internal Port SAS HBA with RAID
NOTE: Supports SAS and SATA disk drive. RAID 0,1 supported.
NOTE: Please see the HBA QuickSpecs for additional information: http://h18004.www1.hp.com/products/quickspecs/12332_na/12332_na.html
(8 Internal Port SAS HBA)
SAS Cables
346914-B21
399550-B21
383280-B21
405148-B21
337972-B21
372538-B21
381513-B21
347786-B21
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 19
QuickSpecs
Options
HP ProLiant DL360 Generation 5
HP Mini SAS 4i 13.4 inch/0.35 m cable
NOTE: Used to connect Smart Array P400i to DL360 G5 5th and 6th drive bays.
HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable
NOTE: Used to connect SA-P600, SA-P400, SA-E200 Controllers to the HP
ProLiant DL360 G5 drive backplane. This kit supports all six drive bays.
SCSI Controllers for External Drive/Storage Support
Smart Array 6402/128 Controller
NOTE: For support of external drives only.
Smart Array 6404/256 Controller
NOTE: For support of external drives only.
Smart Array 642 Controller
NOTE: For support of external drives only.
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the Smart Array 642 Controller.
512 MB Battery-Backed Cache Upgrade
NOTE: This 512-MB Battery-Backed Cache Module upgrade kit supports the
Smart Array P600 Controller and the Smart Array 6400 series Controller.
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
SCSI HBA
HP SC11Xe Host Bus Adapter
NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/10429_na/10429_na.HTML
(SCSI Adapter) http://h18000.www1.hp.com/products/quickspecs/11555_na/11555_na.HTML
(U320 Adapter) http://h18000.www.1.hp.com/products/quickspecs/11943_na/11943_na.HTML
(U320 SCSI HBA) http://h18000.www1.hp.com/products/quickspecs/12566_na/12566_na.HTML
(SC11XE HBA)
399546-B21
411100-B21
273915-B21
273914-B21
291967-B21
351580-B21
372538-B21
374654-B21
412911-B21
Communications
HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter
HP NC310F PCI-X 1000SX Gigabit Server Adapter
HP NC320T PCI Express 1000T Gigabit Server Adapter
HP NC340T PCI-X 4-port 1000T Gigabit Server Adapter
HP NC360T PCI Express Dual Port Gigabit Server Adapter
HP NC373F PCI Express Multifunction Gigabit Server Adapter
HP NC373T PCI Express Multifunction Gigabit Server Adapter
HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter
HP NC510F PCIe 10 Gigabit Server Adapter
NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each
NC510F adapter.
HP NC510C PCIe 10 Gigabit Server Adapter
NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each
NC510C adapter.
HP NC1020 PCI 1000T Gigabit Server Adapter
NOTE: Any NIC (except the NC1020) on the option list can be used for redundancy with the embedded Dual NC373i Multifunction Gigabit NICs. When teaming with other NICs or with the embedded NIC, the lack of Jumbo Frames and LSO features on the NC1020 will cause high end NICs to have those features disabled.
HP IB 4X SDR PCI-e single PORT HCA
367132-B21
368169-B21
367047-B21
391661-B21
412648-B21
394793-B21
394791-B21
394795-B21
414126-B21
414129-B21
353377-B21
431038-B21
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 20
QuickSpecs
Options
HP IB 4X DDR PCI-e Single PORT HCA
HP ProLiant DL360 Generation 5
High Performance
Solutions
HPCC Myrinet Fiber NIC
Tape Drives
NOTE: For the complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the following:
USB Tape Drives
HP StorageWorks DAT 40 USB Internal Tape Drive (Carbonite)
NOTE: HP recommends combining this tape drive with the 1U USB Rack-Mount kit (A8007A) for a complete rack-mount solution.
HP StorageWorks 1U USB Rack-Mount Kit with one DAT 72 USB Tape Drive
SAS Tape Drives
NOTE: Connecting hard drive cage and SAS tape to the same SAS Controller using split cable (supplied with tape drive) deactivates 1 of the hard drive bays.
Actual hard drive bay deactivated depends on where split cable plugs into SAS drive connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard drive cage would mean drive bay 8 is deactivated.
HP StorageWorks Ultrium 448 SAS Internal Tape Drive
NOTE: HP recommends combining this tape drive with the 1U SAS Rack-Mount kit (AE459A) for a complete rack-mount solution.
HP StorageWorks Ultrium 920 SAS Internal Tape Drive
NOTE: HP recommends combining this tape drive with the 1U SAS Rack-Mount kit (AE459A) for a complete rack-mount solution.
NOTE: Please refer to the "Tape Drives, Tape Autoloaders & Tape Libraries" table in the Storage section of this document for a list of SAS controllers with tape support.
Ultrium Tape Drives
HP StorageWorks Ultrium 232 Internal Tape Drive (Carbonite)
NOTE: HP recommends combining this tape drive with the 1U SCSI Rack-
Mount kit (A7445B) for a complete rack-mount solution.
HP StorageWorks 1U Rack-mount kit with one Ultrium 448 (Carbonite)
HP StorageWorks 1U SCSI Rack-mount kit with one Ultrium 920
NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional options such as controllers, media, and other related items: http://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html
http://h18006.www1.hp.com/products/quickspecs/12128_na/12128_na.html
For an up-to-date listing of the latest O/S and software support details for HP
Ultrium tape drives, please visit: http://www.hp.com/go/connect
DAT Drives
HP StorageWorks DAT 72 SCSI Internal Tape Drive (Carbon)
NOTE: HP recommends combining this tape drive with the 1U SCSI Rack-
Mount kit (A7445B) for a complete rack-mount solution.
NOTE: Please see the DAT Tape Drive QuickSpecs for controllers, media, and other options: http://h18000.www1.hp.com/products/quickspecs/11883_na/11883_na.HTML
For an up-to-date listing of the latest O/S and software support details for HP
DAT drives, please visit: http://www.hp.com/go/connect
Rack-Mount Tape Drive Enclosures
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006
431039-B21
257894-006
DW022A
AG594A
DW085A
EH847A
DW064A
DW028B
EH903A
Q1523B
Page 21
QuickSpecs
Options
HP ProLiant DL360 Generation 5
HP StorageWorks 1U SCSI Rack-Mount kit
NOTE: The 1U Rack-Mount Kit can support up to (2) half-height tape drives and is compatible with multiple Single-Ended and LVD SCSI tape drives including the DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232,
Ultrium 448 and Ultrium 920 tape drives.
HP StorageWorks 1U USB Rack-Mount Kit
NOTE: The 1U USB Rack-Mount Kit can support up to (2) half-height tape drives and is compatible with the DAT 24 USB, DAT 40 USB and DAT 72 USB tape drives.
HP StorageWorks 1U SAS Rack-Mount Kit
NOTE: The 1U SAS Rack-Mount Kit can support up to (2) half-height tape drives and is compatible with the Ultrium 448 SAS tape drive.
NOTE: Connecting hard drive cage and SAS tape to the same SAS Controller using split cable (supplied with tape drive) deactivates 1 of the hard drive bays.
Actual hard drive bay deactivated depends on where split cable plugs into SAS drive connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard drive cage would mean drive bay 8 is deactivated.
NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional information regarding these kits: http://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.HTML
A7445B
A8007A
AE459A
Tape Autoloaders HP StorageWorks DAT Autoloader
HP StorageWorks DAT 72x10 tape autoloader
HP StorageWorks 1/8 Tape Autoloader
HP StorageWorks 1/8 Ultrium 960 Tape Autoloader
HP StorageWorks 1/8 Ultrium 920 G2 Tape Autoloader
HP StorageWorks 1/8 Ultrium 448 G2 Tape Autoloader
HP StorageWorks 1/8 Ultrium 232 G2 Tape Autoloader
HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit
NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions
1/8 Tape Autoloader Rackmount Kit
NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack.
NOTE: Please reference the Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs .
AE313A
AF204A
AH165A
AH164A
AH163A
AH166A
C9268R
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 22
QuickSpecs
Options
Tape Libraries
HP ProLiant DL360 Generation 5
HP StorageWorks MSL2024 Tape Library
HP StorageWorks MSL2024 1 Ultrium 960 Drive Library
HP StorageWorks MSL2024 1 Ultrium 960 4GB FC Library
HP StorageWorks MSL2024 1 Ultrium 920 Drive Library
HP StorageWorks MSL2024 2 Ultrium 920 Drive Library
HP StorageWorks MSL2024 1 Ultrium 448 Drive Library
HP StorageWorks MSL2024 2 Ultrium 448 Drive Library
HP StorageWorks MSL4048 Tape Library
HP StorageWorks MSL4048 1 Ultrium 448 Drive Library
HP StorageWorks MSL4048 2 Ultrium 448 Drive Library
HP StorageWorks MSL4048 1 Ultrium 920 Drive Library
HP StorageWorks MSL4048 2 Ultrium 920 Drive Library
HP StorageWorks MSL4048 1 Ultrium 960 Drive Library
HP StorageWorks MSL4048 1 Ultrium 960 4GB FC Library
HP StorageWorks MSL4048 2 Ultrium 960 Drive Library
HP StorageWorks MSL4048 2 Ultrium 960 4GB FC Library
HP StorageWorks MSL6000 Tape Library
Ultrium 960 technology
HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library
HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library
HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library
HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library
Ultrium 460 technology
HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library
HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library
HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library
HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library
NOTE: Please reference the MSL2024, MSL4048 and MSL6000 Tape Library
QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs .
AG323A
AG325B
AD606B
AD608B
AD607B
AD609B
AD598B
AD600B
AD599B
AD601B
AG115A
AG326B
AH169A
AH170A
AG116A
AG117A
AG320A
AG321A
AH171A
AH172A
AG322A
AG324B
HP Data Protector
Express Software
HP DP Express Backup Server Upgrade for ProLiant Software
HP DP Express Package for Microsoft Small Business Server
NOTE: To obtain a free licensed copy of HP Data Protector Express for ProLiant edition software, please visit the "Protect Your Data" link accessible from your
ProLiant server's System Management Homepage (SMH) software (SmartStart
7.5 or later).
NOTE: Please see the HP Data Protector Express QuickSpecs for additional information regarding the purchase of HP Data Protector Express software: http://h18000.www1.hp.com/products/quickspecs/12337_na/12337_na.html
BB117AP
BB118AA
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 23
QuickSpecs
HP ProLiant DL360 Generation 5
Options
HP StorageWorks
Modular Smart Array
20
HP StorageWorks Modular Smart Array 20
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies.
HP StorageWorks Modular Smart Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller.
NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA
1.5Gb/s 3.5” Hot Plug Hard Drives.
335921-B21
366172-B21
HP StorageWorks
Modular Smart Array
30
HP StorageWorks Modular Smart Array 30 SB
NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies
HP StorageWorks Modular Smart Array 30 DB
NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies
NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3,
Ultra320 Hot Plug Hard Drives.
302969-B21
302970-B21
364430-B21
HP StorageWorks
Modular Smart Array
50
HP StorageWorks Modular Smart Array 50 Enclosure
NOTE: Please see the Modular Smart Array 50 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.HTML
HP StorageWorks
Modular Smart Array
500
HP StorageWorks Modular Smart Array 500 Generation 2
NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.HTML
335880-B21
HP StorageWorks
Modular Smart Array
1000
HP StorageWorks Modular Smart Array 1000
NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML
HP StorageWorks
Modular Smart Array
1500 cs
Modular Smart Array 1500 Controller Shelf
NOTE: Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options and configuration information at: http://www.hp.com/go/MSA1500cs
201723-B22
AA986A
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 24
QuickSpecs
Options
Cluster Options
HP ProLiant DL360 Generation 5
ProLiant Cluster Starter Kit
NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html
HP HA/F200 for Entry SAN Cluster
NOTE: For additional information regarding the ProLiant Cluster for Entry Level
SAN please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html
NOTE: For configuration/certification options for the HP Parallel Database
Cluster for Oracle RAC please go to: http://www.hp.com/solutions/highavailability/oracle
HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 & 10 and
Red Hat EL 3 & 4 (2 node license cluster kit)
HP Serviceguard for Linux A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 &
4 (single license version)
364023-B22
364026-B22
305199-B26
307754-B26
HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription T2798AA#001
HP Serviceguard for Linux and Red Hat Global File System - 3 years subscription
T2798AA#003
NOTE: For additional information regarding HP Serviceguard for Linux, please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html
NOTE: For configuration/certification options for HP Serviceguard for Linux please go to: http://www.hp.com/info/sglx
StorageWorks
Options
NOTE: The following is a list of all Fibre Channel Host Bus Adapters for
Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html
HP StorageWorks FC2142SR 4Gb PCI-e HBA
HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-e HBA
HP StorageWorks FC1142SR 4Gb PCI-e HBA
HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA
HP StorageWorks FC2143 4Gb PCI-X 2.0 -to-Fibre Channel HBA
HP StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 HBA
HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA
HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 HBA
Uninterruptible Power
Systems – Rack
Mountable
HP, R1.5kVA UPS, 1U
HP R3000 VA UPS, 2U, L5-30
HP R3000 VA UPS, 2U, L6-20
HP R5500 VA UPS
Power Cords
NOTE: The HP ProLiant DL360 G5 ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs).
Nema 5-15P to IEC320-C13
A8002A
A8003A
AE311A
AE312A
AD167A
AD168A
AB429A
AE369A
AF419A
AF422A
AF423A
AF426A
AF556A
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 25
QuickSpecs
HP ProLiant DL360 Generation 5
Options
HP Monitored Power
Distribution Unit (PDU)
HP Monitored Power Distribution Unit: Full Rack Version
17.3 kVA Monitored PDU Model S2324
8.6 kVA Monitored PDU Model S1324
16.6 kVA Monitored PDU Model S2140
8.3 kVA Monitored PDU Model S1140
22 kVA Monitored PDU Model S2316
11 kVA Monitored PDU Model S1316
14.7 kVA Monitored PDU Model S2132
7.3 kVA Monitored PDU Model S1132
4.9kVA Monitored PDU model S124
7.3kVA Monitored PDU model S132
AF503A
AF504A
AF505A
AF506A
AF507A
AF508A
AF509A
AF510A
AF914A
AF915A
Modular PDUs 1U/0U
(Up to 32 outlets)
NOTE: 1U/0U mounting brackets shipped with the unit (optimized for
10000 and 9000 series racks).
Fixed Cord Extension Bars
NOTE: Two extension bar sticks; each with (7) C13 plugs.
Fixed Cord PDU
NOTE: Four Fixed Cord Extension Bars, and one 24A, HV mPDU L6-30P core.
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127
VAC)
NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR.
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240
VAC)
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240
VAC)
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.
HP Modular Power Distribution Unit(mPDU), High Volt Model, 16A (200-240
VAC)
HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached
Cord
NOTE: This PDU has a detachable input power cord. This model may also be used with the high volt UPSs R3000 XR and R6000, need to order cable PN
340653-001.
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U
Modular PDUs) QuickSpecs for additional options including shorter jumper cables: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.HTML
USB Options
HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver)
USB 1.44-MB External Diskette Drive (Carbonite)
HP USB 04 Standard Keyboard
USB 2.0 4-port HUB
HP 1GB Drive Key II – USB 2.0 Flash Drive
HP 512MB DriveKey II – USB Flash Drive
351655-B21
351655-D72
252663-D71
252663-D72
252663-B21
252663-B24
252663-D73
DC172B
DC141B
DT528A#xxx
DG954A
AG382AA
ED516AA
399542-B21
HP ProLiant DL360
G5 Deployment
Options
700W HP redundant power supply with IEC cord only
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 26
QuickSpecs
Options
HP Rack 5000 Series
(Graphite Metallic)
HP ProLiant DL360 Generation 5
HP 5642 Rack Unassembled
NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.HTML
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower .
358254-B21
HP Rack 10000 G2
Series
(Carbon/Graphite
Metallic)
10642 G2 (42U) Rack Cabinet - Pallet
10642 G2 (42U) Rack Cabinet - Shock Pallet
10642 G2 (42U) Rack Cabinet - Crated
10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet
10636 G2 (36U) Rack Cabinet - Pallet
10636 G2 (36U) Rack Cabinet - Shock Pallet
10636 G2 (36U) Rack Cabinet - Crated
10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed.
NOTE: Please see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.HTML
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower .
AF001A
AF002A
AF003A
AF004A
AF011A
AF012A
AF013A
AF014A
HP Rack 10000 Series
(Graphite Metallic)
10642 (42U) Infrastructure Rack (Low Voltage)
10642 (42U) Infrastructure Rack (High Voltage)
HP Rack S10614 (14U) Rack Cabinet – Shock Pallet
HP Rack 10842 (42U, 800mm wide) – Pallet
HP Rack 10842 (42U, 800mm wide) – Shock Pallet
HP Rack 10647 (47U) – Pallet
HP Rack 10647 (47U) – Crated
HP Rack 10622 (22U) – Pallet
HP Rack 10622 (22U) – Shock Pallet
HP Rack 10622 (22U) – Crated
NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck.
xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty racks.
NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. Not all HP equipment is qualified to be shipped in the Rack
10000 series
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower
379006-001
379005-001
292302-B22
257415-B21
257415-B22
245160-B21
245160-B23
245163-B21
245163-B22
245163-B23
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 27
QuickSpecs
Options
Keyboards and
Monitors
HP ProLiant DL360 Generation 5
TFT7210R Rack Mounted 17" Monitor
NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm .
TFT7600 Rackmount Keyboard Monitor
1U Rackmount Keyboard with USB
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower .
348373-B21
AG052A
AG072A
HP KVM Switch
Options
HP Serial Console
Server Options
2x1x16 IP Console Switch with Virtual Media
4x1x16 IP Console Switch with Virtual Media
2x16 Server Console Switch with Virtual Media
PS/2 Virtual Media Interface Adapter, 1 pack
NOTE: Requires PS/2 and one USB port on server.
Server Console Switch (KVM), 0 x 1 x 8 port
Server Console Switch (KVM), 0 x 2 x 16 port
PS/2 Interface Adapter, 1 pack
PS/2 Interface Adapter, 8 pack
USB Interface Adapter, 1 pack
Serial Interface adapter - 1 Pack with power supply
NOTE: Cat5e cables are required to connect Interface Adapters to Console
Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm .
HP 1x 4 USB/PS2 KVM Switch, TT
HP 1x 4 USB/PS2 KVM Switch, RM
HP PS2 KVM Cable with audio, 6', 2-pack
HP USB KVM Cable with audio, 6', 2-pack
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm .
AF601A
AF602A
AF600A
AF604A
336044-B21
336045-B21
262588-B21
262587-B21
336047-B21
373035-B21
371301-D71
371302-B21
371730-B21
371729-B21
HP 16 Port Serial Console Server
HP 48 Port Serial Console Server
Serial Adapter, RJ45-DB9 DCE Female, 1 Pack
Serial Adapter, RJ45-DB9 DCE Female, 8 Pack
NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console
Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm .
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm .
AF101A
AF102A
AF103A
AF110A
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 28
QuickSpecs
HP ProLiant DL360 Generation 5
Options
Service and Support
Offerings (HP Care
Pack Services)
Hardware Services 4-Hour On-site Service
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
Hardware Services 6-Hour Call to Repair On-site Service
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Hardware Services Next Business Day On-Site Service
Hardware Installation, Electronic
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet. To be delivered on a scheduled basis
8am-5pm, M-F, excl. HP holidays, Electronic
Support Plus
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl.
HP holidays, Electronic
Support Plus 24
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays,
Electronic
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays,
Electronic
Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays,
Electronic
NOTE: For more information, customer/resellers can contact http://www.hp.com/services/carepack .
U4496E
U4497E
U4498E
U4506E
U4507E
U4508E
U4509E
U6310E
U8332E
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 29
QuickSpecs
Memory
HP ProLiant DL360 Generation 5
NOTE: Memory configurations listed do not apply to "Factory Integrated Models".
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at 667 MHz and in systems with a FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533 MHz.
HP ProLiant DL360 G5 Entry and Base Models
Standard Memory
1 GB PC2-5300 Fully Buffered DIMMs (DDR2-667) installed (2 x 512 MB)
Upgrading Memory and Memory Interleaving
When upgrading memory, DIMMs 1A and 2A must match. DIMMs 3B and 4B, DIMMs 5C and 6C, and DIMMs 7D and 8D must match and must be installed as a pair. When DIMMs 1A and 2A are populated the system is automatically configured for 2:1 interleaving. When all 4 banks are populated the system is automatically configured for 4:1 interleaving. When four, six, or eight DIMMs are populated with identical DIMMs the system is automatically configured for bank interleaving.
Standard Memory Plus Optional Memory
Up to 25 GB memory is available with the standard memory of 1 GB and the optional installation of PC2-5300 Fully Buffered
DIMMs (DDR2-667) memory kits.
Standard Memory Replaced with Optional Memory
Up to 32 GB of memory is available with the removal of the standard 512 MB of memory and the optional installation of
PC2-5300 Fully Buffered DIMMs (DDR2-667) memory kits.
NOTE: 4 GB Fully Buffered DIMMs kits will be available shortly following server availability to allow a maximum of 32 GB.
Today's maximum is 16 GB utilizing 2 GB DIMMs.
NOTE: Chart does not represent all possible configurations.
Memory Slot
1 2 3 4 5 6 7 8
Standard
Optional
Maximum
1 GB
25 GB
32 GB
512 MB
512 MB
4 GB
512 MB
512 MB
4 GB
Empty
4 GB
4 GB
Empty
4 GB
4 GB
Empty
4 GB
4 GB
Empty
4 GB
4 GB
Empty
4 GB
4 GB
Empty
4 GB
4 GB
NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank,
If banks A, B, C and D are populated, bank D is the spare bank, Online spare memory is configured through RBSU.
NOTE: Mirrored Memory uses mirrored banks to provide a high level of memory redundancy. Customer chooses to implement or not: User selectable via BIOS and default is off.
Following are memory options available from HP:
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
397409-B21
397411-B21
397413-B21
397415-B21
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 30
QuickSpecs
HP ProLiant DL360 Generation 5
Memory
HP ProLiant DL360 G5 Performance Models
Standard Memory
2 GB PC2-5300 Fully Buffered DIMMs (DDR2-667) (2 x 1 GB)
Upgrading Memory and Memory Interleaving
When upgrading memory, DIMMs 1A and 2A must match. DIMMs 3B and 4B, DIMMs 5C and 6C, and DIMMs 7D and 8D must match and must be installed as a pair. When DIMMs 1A and 2A are populated the system is automatically configured for 2:1 interleaving. When all 4 banks are populated the system is automatically configured for 4:1 interleaving. When four, six, or eight DIMMs are populated with identical DIMMs the system is automatically configured for bank interleaving.
Standard Memory Plus Optional Memory
Up to 14 GB memory is available with the standard memory of 2 GB and the optional installation PC2-5300 Fully Buffered
DIMMs (DDR2-667) memory kits.
Standard Memory Replaced with Optional Memory
Up to 32 GB of memory is available with the removal of the standard 1 GB of memory and the optional installation of PC2-
5300 Fully Buffered DIMMs (DDR2-667) memory kits.
NOTE: Chart does not represent all possible configurations.
Memory Slot
1 2 3 4 5 6 7 8
Standard
Optional
Maximum
2 GB
14 GB
32 GB
1 GB
1 GB
4 GB
1 GB
1 GB
4 GB
Empty
2 GB
4 GB
Empty
2 GB
4 GB
Empty
2 GB
4 GB
Empty
2 GB
4 GB
Empty
2 GB
4 GB
Empty
2 GB
4 GB
NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank,
Online spare memory is configured through RBSU.
NOTE: Mirrored Memory uses mirrored banks to provide a high level of memory redundancy. Customer chooses to implement or not: User selectable via BIOS and default is off.
Following are memory options available from HP:
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
397409-B21
397411-B21
397413-B21
397415-B21
Online spare FBDIMM configuration requirements (in addition to general configuration requirements):
When only bank A is being used, it must be fully populated with dual-rank FBDIMMs.
If banks A and C are being used, they must be fully populated.
If installed, bank A and bank C must contain FBDIMMs with identical part numbers.
If installed, bank B and bank D must also contain FBDIMMs with identical part numbers.
In online spare mode, FBDIMMs must be populated as specified in the following table:
Configuration Branch 0
Bank A
1A and 3A
Branch 0
Bank C
2C and 4C
Branch 1
Bank B
5B and 7B
1 *
2
X
X X
-
-
3 X X X
*NOTE: Configuration 1 is only supported if using bank A, populated with dual-rank FBDIMMs.
Branch 1
Bank D
6D and 8D
X
-
-
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 31
QuickSpecs
HP ProLiant DL360 Generation 5
Memory
Mirrored memory FBDIMMs configuration requirements (in addition to general configuration requirements):
Banks A and B must be fully populated.
Bank A and bank B must contain FBDIMMs with identical part numbers. If installed, bank C and bank D must also contain FBDIMMs with identical part numbers.
When using mirrored memory mode, FBDIMMs must be populated as specified in the following table:
Configuration
1
2
Bank A
1A and 3A
X
X
Bank B
5B and 7B
X
X
Bank C
2C and 4C
X
-
Bank D
6D and 8D
X
-
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 32
QuickSpecs
Storage
HP ProLiant DL360 Generation 5
1-6
A
6 x SFF SAS Hot Pluggable Hard Drive
Bays
Slimline Bay: Optional optical or floppy drive
Drive Support
Removable Media
Slimline 1.44-MB
Diskette Drive
Slimline 24x IDE CD-
ROM Drive
Slimline DVD-ROM
Drive (8x/24x) Option Kit
(Servers)
Slimline DVD/CD-RW
Combo Option Kit
Slimline DVD-RW Drive
(8X) Option Kit
Quantity
Supported
Up to 1
Up to 1
Up to 1
Up to 1
Up to 1
Position
Supported Controller
A Integrated
A
A
Integrated IDE
Integrated IDE
A
A
Integrated IDE
Integrated IDE
Hard Drives
SAS Hard Drive
Quantity
Supported
Position
Supported Controller
146GB 3G SAS 10K SP
72GB 3G SAS 10K SP
36GB 3G SAS 10K SP
6 1-6 HP Smart Array E200i/64MB Controller
HP Smart Array P400i/512MB BBWC Controller
HP Smart Array P400i/256MB Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
Please see NOTES below regarding hard drive quantity supported by Smart Array Controller.
NOTE: The Smart Array E200i Controller can support a maximum of 4 hard drives.
NOTE: The Smart Array P400i Controller can support a maximum of 6 hard drives. To support drives 5 and 6, the optional
HP Mini SAS 4i 13.4 inch/0.35 m cable is required (PN 399546-B21).
NOTE: The Smart Array P600 Controller requires HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 33
QuickSpecs
HP ProLiant DL360 Generation 5
Storage
Serial-ATA (SATA) Hard Drive
60GB 1.5G SATA 5.4K
Quantity
Supported
6
Position
Supported Controller
1-6 HP Smart Array E200i/64MB Controller
HP Smart Array P400i/512MB BBWC Controller
HP Smart Array P400i/256MB Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
Please see NOTES below regarding hard drive quantity supported by Smart Array Controller.
NOTE: The Smart Array E200i Controller can support a maximum of 4 hard drives.
NOTE: The Smart Array P400i Controller can support a maximum of 6 hard drives. To support drives 5 and 6, the optional
HP Mini SAS 4i 13.4 inch/0.35 m cable is required (PN 399546-B21).
NOTE: The Smart Array P600 Controller requires HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (PN 411100-B21).
External Storage
Modular Smart Array 20
Family
Modular Smart Array 30
Family
Modular Smart Array 50
Enclosure
Modular Smart Array
500 G2 System
Quantity
Supported
Please see the
Modular Smart
Array 20
QuickSpecs to determine configuration requirements
Please see the
Modular Smart
Array 30
QuickSpecs to determine configuration requirements.
2
1
Modular Smart Array
1500 cs
Position
Supported Host Controller or Adapter
External Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
External
External
External
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
HP Smart Array P600/256 BBWC Controller
Smart Array 642 Controller (used as Host Bus Adapter)
Please see the Modular Smart Array 500 G2 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500
External Please see the Modular Smart Array 1500 cs QuickSpecs (URL below) for the latest list of supported HBAs
Modular Smart Array
1000
Please see the
Modular Smart
Array 1500 cs
QuickSpecs below to determine configuration requirements
Please see the
Modular Smart
Array 1000
QuickSpecs below to determine configuration requirements
External Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 34
QuickSpecs
Storage
Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML
Modular Smart Array 1500 cs: http://www.hp.com/go/MSA1500cs
HP ProLiant DL360 Generation 5
Tape Drives, Tape Autoloaders, & Tape Libraries
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following: http://h18000.www1.hp.com/products/quickspecs/North_America/10233.html
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders and Tape Libraries listed below, please see the following: http://h18000.www1.hp.com/products/quickspecs/North_America/10809.html
NOTE: SAS Tape Drives: Connecting hard drive cage and SAS tape to the same SAS Controller using split cable (supplied with tape drive) deactivates 1 of the hard drive bays. Actual hard drive bay deactivated depends on where split cable plugs into SAS drive connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard drive cage would mean drive bay 8 is deactivated.
NOTE: For complete listing of tape drive offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the following:
Position
Supported
Controller
HP StorageWorks
Tape Drives, External
Ultrium 232
Ultrium 448
Ultrium 460
Ultrium 960
Ultrium 920
DAT 40
DAT 72
DLT VS160
SDLT 320
SDLT 600
External HP SC11Xe Host Bus Adapter
External USB 2.0 Port
HP StorageWorks
Tape Drives, External
DAT 24 USB
DAT 40 USB
DAT 72 USB
HP StorageWorks
Tape Drives, SAS
External
Ultrium 448 SAS
Ultrium 920 SAS
HP StorageWorks
Autoloaders, External
DAT 72x10 Autoloader
1/8 Tape Autoloader
External
External
HP 8 Internal Port SAS HBA with RAID 0/1
NOTE: Please visit http://www.hp.com/go/connect
HP SC11Xe Host Bus Adapter
Controller Part
Number
for details about minimum
SAS controller firmware version and SAS cabling requirements.
412911-B21
N/A
347786-B21
412911-B21
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 35
QuickSpecs
Storage
HP StorageWorks
SCSI Rack-Mount
Tape Drive
Enclosures
1U Rack-Mount Kit
3U Rack-Mount Kit
HP StorageWorks
USB Rack-Mount
Tape Drive
Enclosures
1U Rack-Mount Kit
HP StorageWorks
SAS Rack-Mount
Tape Drive
Enclosures
1U Rack-Mount Kit
External
External
External
HP StorageWorks
Tape Libraries,
External
MSL2024 (Ultrium 448,
Ultrium 920 and 960based)
MSL4048 (Ultrium 448,
Ultrium 920 and 960based)
MSL6000 (Ultrium 960 and 460-based)
MSL6000 (SDLT 600based)
External
HP SC11Xe Host Bus Adapter
USB 2.0 Port
HP ProLiant DL360 Generation 5
HP 8 Internal Port SAS HBA with RAID 0/1
412911-B21
N/A
347786-B21
NOTE: Please visit http://www.hp.com/go/connect for details about minimum
SAS controller firmware version and SAS cabling requirements.
Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information.
N/A
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 36
QuickSpecs
Power Specifications
HP ProLiant DL360 Generation 5
To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL360 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 37
QuickSpecs
Technical Specifications
System Unit
HP ProLiant DL360 Generation 5
Dimensions (H x W x D) 1.70 x 16.78 x 27.75 in (4.32 x 42.62 x 70.49 cm)
Weight
Maximum (six hard drives installed, two power supply, two processor)
No hard drives installed, one power supply, one processor
37 lb (16.78 kg)
27.5 lb (12.47 kg)
Input Requirements
Rated Input Voltage
Rated Input Current
100 to 240 VAC
7.1 Amps (at 120VAC) to 3.5 Amps (240 at
VAC)
Rated Input Frequency 50 to 60 Hz
Rated Input Power 852 W
BTU Rating
2910 BTU/HR (at 120 VAC); 2870 (at 240 VAC)
NOTE: The BTU rating listed is for the Rated Input Power of 852 W.
Power Specifications
To review typical system power ratings use the Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc
/Power%20Calculator%20Catalog.xls
Power Supply Output
Power
(per power supply)
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL360 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
Rated Steady-State
Power
Temperature Range
Operating
700 W
Storage
50° to 95°F (10° to 35°C) at sea level with an altitude derating of 1.0°C per every 1000 ft
(300 m) above sea level to a maximum of
10,000 ft (3000 m), no direct sustained sunlight. Maximum rate of change is 10°C/Hr.
-40° to 158°F (-40° to 70°C) – Maximum rate of change is 20°C/Hr.
Relative Humidity
(non-condensing)
Operating
Storage
82.4°F (28°C)
10 to 90% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature
5 to 95% relative humidity (Rh), based upon a maximum temperature of 113° F (45° C).
Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.
Maximum Wet Bulb
Temperature
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 73.4°F (23°C) ambient environment. Noise emissions were measured in accordance with ISO
7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA
109).
Idle:
L
WAd
(BELS) 6.6
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 38
QuickSpecs
Technical Specifications
Smart Array E200i
Controller
HP ProLiant DL360 Generation 5
L pAm
(dBA)
Operating:
L
WAd
(BELS)
L pAm
(dBA)
50
6.9 BELS
53 dBA
Disk Drive and
Enclosure Interface
3G SAS (Serial Attached SCSI)
1.5G SATA (Serial Advanced Technology Attachment)
SAS Connectors
2 internal (SFF8484) x4 wide port connectors
Cache Memory Speed DDR-1/266 MHz provides up to 4.2 GB/s maximum bandwidth.
Server Interface
SAS Speed
Cache Memory
x4 2.5G PCIe provides 2GB/s maximum bandwidth.
x8 3G SAS provides 2.4GB/s maximum bandwidth.
40-bit 64MB or 128MB cache: ECC protection, battery-backed, and transportable
Up to 32 logical volumes
Logical Volumes
Supported
Maximum Volume
Capacity
Host Memory
Addressing
3TB (6 x 500GB)
64-bit, supporting greater than 4GB server memory space
RAID Support
RAID 5 (Distributed Data Guarding) requires 128MB BBWC option
RAID 1, 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Upgradeable Firmware Upgradeable Firmware
Smart Array P400i
Controller
Disk Drive and
Enclosure Interface
3G SAS (Serial Attached SCSI)
1.5G SATA (Serial Advanced Technology Attachment)
2 internal (SFF8484) x4 wide port connectors
SAS Connectors
Cache Memory Speed DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth.
Server Interface
x8 2.5G PCIe provides 2GB/s maximum bandwidth.
SAS Speed
Cache Memory
x8 3G SAS provides 2.4GB/s maximum bandwidth.
40-bit 256MB cache (72-bit 512MB module upgrades available); ECC protection, battery-backed, and transportable
Logical Drives
Supported
Maximum Logical
Drive Capacity
Host Memory
Addressing
RAID Support
Up to 32 logical drives
3 TB (6 x 500GB)
64-bit, supporting greater than 4GB server memory space
RAID 6 with ADG (Advanced Data Guarding) requires Battery Backed
Write Cache Upgrade
RAID 5 (Distributed Data Guarding)
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Upgradeable Firmware Upgradeable Firmware with recovery ROM feature
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 39
QuickSpecs
HP ProLiant DL360 Generation 5
Technical Specifications
Embedded NC373i
Multifunction Gigabit
Server Adapters
Network Interface
10/100/1000-T
Compatibility
EEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
Data Transfer Method
PCI Express, four lanes (x4)
Network Transfer Rate 10Base-T (Half-Duplex) 10 Mb/s
10Base-T (Full-Duplex) 20 Mb/s
100 Mb/s 100Base-TX (Half-
Duplex)
100Base-TX (Full-
Duplex)
200 Mb/s
2000 Mb/s
Connector
Cable Support
1000Base-TX (Half and
Full-Duplex)
RJ-45
10Base-T
10/100/1000 Base-TX
Categories 3, 4 or 5 UTP up to 328 ft (100 m)
Category 5 UTP up to 328 ft (100 m)
© Copyright 2006 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel
Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.
DA - 12476 U.S. QuickSpecs — Version 15 — 12/21/2006 Page 40
advertisement