White Rodgers 1F82-0261 Operating instructions
Add to my manuals12 Pages
Emerson 1F82-0261 is a programmable heat pump thermostat designed for single-stage compressor heat pump systems with 1-stage auxiliary/emergency heat. It features a large backlit display, easy-to-use controls, and multiple programming options, including a 5/1-day programmable schedule. The thermostat also includes energy-saving features such as Energy Management Recovery (EMR) to help save on energy costs. Additionally, the 1F82-0261 has a built-in self-diagnostic system to alert you to any potential issues with your heating or cooling system.
advertisement
Blue 2” Heat Pump Thermostat
Heat Pump Installation and Operating Instructions
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
Thermostat
Configuration
Options
Heat Pump
Single Stage
Compressor
Thermostat
Applications
Single Stage Compressor
Heat Pump Systems – 1
Stage Aux/Emergency Heat
Maximum
Stages
Heat/Cool
2/1
Model
1F82-0261
Programming Choices
5/1/1 Day Programmable
1F82-0261 Thermostat
SPECIFICATIONS
Electrical Rating:
Battery Power or Hardwire ............................. 20 VAC, 50/60 Hz
Terminal Load ........................................................ 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4”H x 4-3/4”W x 1-1/2”D
PRECAUTIONS
!
WARNING
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause shock or fire hazard.
Thermostat installation and all components of the system shall conform to Class II (current limited) circuits per the NEC code. Failure to do so could cause a fire hazard.
!
CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
Index
Installation
Wiring Diagram
Thermostat Quick Reference
Installer Configuration Menu
Operation
Programming
Troubleshooting
Page
6
7
9
4
5
2
3 www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-7022C
Replaces 37-7022B
1023
INSTALLATION
REMOVE OLD THERMOSTAT
1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.
2. Remove the front cover of the old thermostat. With wires
still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.
3. Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat.
4. Disconnect the wires from old thermostat one at a time. DO
NOT LET WIRES FALL BACK INTO THE WALL.
5. Install new thermostat using the following procedures.
Mounting
Hole
ATTENTION!
This product does not contain mercury. However, this product may replace a unit which contains mercury.
Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing nonabsorbent gloves, take up the spilled mercury and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded.
Mercury must not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container. Refer to www.white-rodgers.com for location to send the product containing mercury.
(Ele/Gas)
Switch O/B
Switch
Figure 1. Thermostat Base
FAN (ELE/GAS) SWITCH
For Electric Heat, heat pump or any system that requires the thermostat to turn on the blower on a call for heat - place the
FAN (Ele/Gas) switch (Fig. 1) in the ON position. For Auxiliary and Emergency Heat systems that have a fan control to turn on the blower (independent of the thermostat) place switch in the OFF position.
BATTERY LOCATION
ATTACH THERMOSTAT BASE TO WALL
1. Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat will cause damage to the unit.
2. Place base over hole in wall and mark mounting hole locations on wall using base as a template (see Fig.1).
3. Move base out of the way. Drill mounting holes.
4. Push wires through opening in thermostat base.
5. Fasten base loosely to wall using two mounting screws.
Place a level against bottom of base, adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure subbase.
6. Connect wires to terminals on base using appropriate wiring schematic (see figs. 2 through 4).
7. Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.
O/B TERMINAL SWITCH SELECTION
The O/B switch on this thermostat is factory set to the “O” position. This will accommodate the majority of heat pump applications, which require the changeover relay to be energized in COOL. If the thermostat you are replacing or the heat pump being installed with this thermostat requires a “B” terminal, to energize the changeover relay in HEAT, the O/B switch must be moved to the “B” position.
“AA” Alkaline Batteries
Two “AA” alkaline batteries are installed in your thermostat with a battery tag to prevent power drainage. Prior to use, open the battery door and remove the battery tag. To open, pull the battery door as shown by the arrow and lift open. The two “AA” batteries will operate all functions or maintain time and continuously display the temperature during a loss of AC power. Installed batteries will also allow programming prior to installation. To replace batteries, pull the battery door shown by the arrow and lift open. Using the polarity indicated inside the battery door, insert the batteries. To close the battery door, swing the door down while pulling in the direction of arrow.
Once fully down, snap the door back into position.
Thermostat can be powered by system AC power or Battery. If
is displayed, the thermostat is battery powered. If is not displayed, thermostat is system powered with optional battery back-up. When battery power remaining is approximately half, the will be displayed. When “Change ” is displayed, install fresh “AA” alkaline batteries immediately. For best results, use new premium brand alkaline batteries such as
Duracell® or Energizer®. We recommend replacing batteries every 2 years. If the home is going to be unoccupied for an extended period (over 3 months) and is displayed, the
2
INSTALLATION
batteries should be replaced before leaving. When less than two months of battery life remain, the setpoint temperature will offset by 10 degrees (10 degrees cooler in Heat mode / 10 degrees warmer in Cool mode). If offset occurs, the normal setpoint can be manually reset with or . Another offset will occur within two days if batteries are not replaced. To replace the batteries, set system to OFF.
ENERGY MANAGEMENT RECOVERY
(EMR)
When the Energy Management Recovery (EMR) feature is activated the thermostat will start the program early to achieve the programmed temperature setting by the time specified in the program and minimize Auxiliary Heat use. Heat Pump and
Cooling systems start approximately 15 minutes early for every
1° of temperature (gas or electric heat starts 5 minutes early for every 1°) required to reach the next temperature setting.
This helps the building warm up in Heating or cool down in
Cooling so it reaches the program temperature right on time.
EMR – Heat Pump Example:
If the thermostat is programmed to an overnight heating temperature of 66°F, and the next program period, beginning at
6:00 AM is programmed to 70°F, the thermostat will automatically advance the program setting and start the heating system at about 5:00 AM. The thermostat will use Heat Pump only during the majority of the recovery period. It will use Auxiliary Heat only if the thermostat calculates the Heat Pump will not meet setpoint by the programmed time. This saves money by using the Heat Pump for setback recovery as much as possible and using Auxiliary Heat only if the Heat Pump cannot recover by the time programmed.
To turn EMR off, use the Configuration Menu on page 5. When
EMR is set to OFF the temperature settings will change at exactly your program times.
WIRING DIAGRAM
NOTE
The 24 volt neutral connection to terminal C on thermostat is not required if you replace the batteries once a year with fresh “AA” alkaline batteries.
O/B Y G W2 C
**
L R
THERMOSTAT
SYSTEM
Changeover
Relay*
Compressor
Contactor
Fan
Relay
SYSTEM
MONITOR
SWITCH
Aux/Emergency
Heat Relay
(Stage 2)
* Changeover Relay is energized in COOL when O/B switch is in the “O” position
Changeover Relay is energized in HEAT when O/B switch is in the “B” position
** The 24 volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” alkaline batteries.
24 VAC
Hot
120 VAC
Neutral
TRANSFORMER
(Class II Current Limited)
Figure 2. Typical wiring diagram for single transformer systems
3
THERMOSTAT QUICK REFERENCE
Before you begin programming your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons and switches (see fig. 3). Your thermostat consists of two parts: the thermostat
cover and the base. To remove the cover, pull it straight out from the base. To replace the cover, line up the cover with the base and press until the cover snaps onto the base.
The Thermostat Buttons and Switches
1 Raises temperature setting.
2 Lowers temperature setting.
3
4
5
6
7
TIME button.
SYSTEM switch (COOL, OFF, HEAT, EMER).
PRGM (program) button.
FAN switch (ON, AUTO).
RUN/HOLD (program) button.
The Display
8
9
Indicates days of the week.
Indicates setpoint temperature. This is blank when system switch is in the OFF position. Setpoint temperature is displayed (flashing) if the thermostat is in lockout mode to prevent the compressor from cycling too quickly.
10 “AUX” indicates auxiliary stage is operating.
11 “Save” indicates the Cool Savings feature is enabled in the configuration menu. “Save” (flashing) indicates Cool
Savings feature is active.
12 Flame icon ( ) is displayed when the SYSTEM switch is in the HEAT position. Flame icon ( ) is displayed flashing when thermostat is calling for heat. Snowflake icon (
) is displayed (non-flashing) when the SYSTEM switch is in the COOL position. Snowflake icon ( ) is displayed
(flashing) if the thermostat is calling for cool.
13 Displays current temperature.
14 “Service” indicates a diagnostic fault in the heating/cooling system. It does not indicate a fault in the thermostat.
15 “EMER” is displayed flashing when the system switch is in EMER position, bypassing the Heat Pump.
16 “Change Filter” is displayed when the system has run for the programmed filter time period as a reminder to change or clean your air filter.
17 “ ” indicates power level of batteries. “Change indicates batteries should be replaced.
18 Indicates time.
”
19 “A” “P” indicates time as Morning (A) Evening (P).
20
“Temp Hold” indicates temporary hold or “Hold” indicates hold mode.
3
18
17
16
4
19
5 6
20
7
8
9
10
11
1
2
15 14 13 12
4
INSTALLER/CONFIGURATION MENU
The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.
To enter the menu: Set your thermostat to OFF and press the and buttons simultaneously. The display will show the first item in the configuration menu. Press RUN/HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press PRGM. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.
Menu
Reference
Number
1
2
3
4
5
6
Heat
Pump
1
2
3
4
5
6
Press
Key
Displayed
(Factory
Default)
RUN/HOLD*
RUN/HOLD*
CS
(OFF)
CS
(3)
RUN/HOLD* E
(On)
RUN/HOLD* CR HE-PU
(FA)
RUN/HOLD* CR Aux
(FA)
RUN/HOLD*
RUN/HOLD*
RUN/HOLD*
RUN/HOLD*
CL
(OFF)
L
(On)
Temp
(0 HI) o F
Configuration Menu
Press or to select from listed options
On
1, 2, 3, 4, 5, 6
OFF
SL
SL
On
OFF
Comments
Select Cool Savings Feature On or OFF
If CS selected On, selects Cool Savings value
Select Energy Management Recovery On or OFF
Select Adjustable Anticipation, cycle rate, Heat Pump,
Heat and Cool
Select Adjustable Anticipation, cycle rate,
Heat Pump Aux Stage
Select Compressor lockout OFF or On
Select Display Light On or OFF
7
8
7
8
4 LO to
4 HI o C
Select temperature display adjustment higher or lower
Select o F / o C Display (temperature units in Fahrenheit or
Celsius)
Select fast second stage On or OFF 9
10
11
9
10
RUN/HOLD*
RUN/HOLD*
FH
(On)
RUN/HOLD* Change Filter
(OFF)
RUN/HOLD* Change Filter
(200 h)
OFF
On
25 to 1975
Select filter replacement indicator OFF or On
If Change Filter selected On, selects time interval for
Change Filter Indicator.
(in 25 hour increments)
Returns to normal operation
*Press RUN/HOLD to advance to next item or TIME to move backwards to previous item
1) Select CS (Cool Savings™) - With Cool Savings™ enabled, the thermostat will make small adjustments to the Setpoint temperature during periods of high demand to reduce cooling system running time and save energy.
When the cooling system has been running for more than
20 minutes, humidity in the home will be lower and a higher setpoint temperature will feel comfortable. After 20 minutes of run time, the thermostat will start increasing the setpoint temperature in steps of less than one degree as the system continues to run. These adjustments will eventually cause the system to satisfy the thermostat and turn the system off to reduce the energy consumption. When the Cool
Savings TM feature is active and making adjustments, the display will show “Save”. The amount of the adjustments to the setpoint temperature is dependent on the Cool
Savings TM value that is set, 1 being the least adjustment and 6 being the most adjustment. With this feature set to OFF, no change will occur when the cooling system is continuously running during the periods of high demand.
Periods of high demand will normally occur during the late afternoon and early evening on the hottest days of the summer.
2) Select Energy Management Recovery - Energy
Management Recovery (E) On enables the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. See page 3 for details.
3 & 4) Select Cycle Rate Selection - The factory default setting is (FA, CR) for all modes (Heat Pump, Heat Pump
Aux, Heat and Cool). To change to slow cycling (SL, CR), press the and keys to toggle between FA & SL.
The cycle rate differentials for different settings are:
MODE Fast Slow
Heat Pump
FA
1.2°F
SL
1.7°F
HP Aux 0.8°F 1.2°F
5) Select Compressor Lockout CL OFF or ON - Selecting
CL On will cause the thermostat to wait 5 minutes between cooling cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already have a time delay built in and do not require this
5
INSTALLER/CONFIGURATION MENU
feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay occurs, it will flash the setpoint for up to five minutes.
6) Select Backlight Display - The display backlight improves display contrast in low lighting conditions. When the “C” terminal is connected, selecting backlight CdL On will keep the light on continuously. Select backlight OFF will turn the light on momentarily when any key is pressed. When the “C” terminal is not connected, regardless of the backlight selection, the light will be on momentarily when any key is pressed.
7) Select Temperature Display Adjustment 4 LO to 4 HI -
Allows you to adjust the room temperature display up to 4° higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat. The current or adjusted room temperature will be displayed on the display.
8) Select °F or °C Readout - Changes the display readout to
Celsius or Fahrenheit as required.
9) Select Fast Second Stage ON or OFF - (Heat Pump Only)
In the RUN mode, with the Fast Heat feature enabled (FH
Heat On), if the temperature is manually raised by 3°F (2°C) or more above the actual temperature using the , the second stage will energize immediately. With FH OFF, the thermostat will determine the optimum time (approximately
0 to 30 minutes) to use Auxiliary/Second stage heat in addition to the Heat Pump.
10) Select Filter Replacement Reminder and Set Run
Time Select the “Change Filter” reminder On or OFF. If selected On, press RUN/HOLD to select the time period from 25 to 1975 hours in 25 hour increments. In a typical application, 200 hours (default) of run time is approximately
30 days. After the selected time of blower operation, the thermostat will display “Change Filter” as a reminder to change or clean your air filter. When “Change Filter” is displayed, press the RUN/HOLD button to clear the display and restart the time to the next filter change. A selection of
OFF will cancel this feature.
11) Select RUN/HOLD - Exit Menu.
OPERATION
CHECK THERMOSTAT OPERATION
If at any time during testing your system does not operate properly, contact a qualified service person.
Turn on power to the system.
Emergency System
EMER bypasses the Heat Pump to use the heat source wired to terminal W2 on the thermostat. EMER is typically used when compressor operation is not desired, or you prefer back-up heat only.
Fan Operation
If your system does not have a G terminal connection, skip to
Heating System.
1. Move fan switch to ON position. The blower should begin to operate.
2. Move fan switch to AUTO position. The blower should stop immediately.
1. Move SYSTEM switch to EMER position, EMER will flash on the display.
2. Press to adjust the thermostat above room temperature.
The Aux heating system will begin to operate. The Flame icon ( ) will display flashing to indicate that the Aux system is operating.
3. Press to adjust the thermostat below room temperature.
The Aux heating system should stop operating.
Heating System
1. Move SYSTEM switch to HEAT position. If the auxiliary heating system has a standing pilot, be sure to light it.
2. Press to adjust thermostat setting to 1° above room temperature. The Flame icon ( ) will flash and the Heat
Pump system should begin to operate. However, if the setpoint temperature is flashing, the compressor lockout feature is operating (see Configuration menu, item 5).
3. Adjust temperature setting to 4 o above room temperature.
The auxiliary heat system should begin to operate and the
Aux icon will be flashing.
4. Press to adjust temperature setting below room temperature. The heating system should stop operating.
Cooling System
!
CAUTION
To prevent compressor and/or property damage, if the outdoor temperature is below 50 o F, DO NOT operate the cooling system.
1. Move SYSTEM switch to COOL position.
2. Press to adjust thermostat setting below room temperature. The blower should come on immediately on high speed, followed by cold air circulation.
3. Press to adjust temperature setting above room temperature. The cooling system should stop operating.
6
PROGRAMMING
!
CAUTION
Do not allow the compressor to run unless the compressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes.
MANUAL OPERATION
• HOLD TEMPERATURE — With the SYSTEM switch set to HEAT or COOL, momentarily press RUN/HOLD button.
HOLD will be displayed. Use or to adjust the temperature. The thermostat will hold the room temperature at the selected setting until you press RUN/HOLD button to start program operation again.
• TEMPERATURE OVERRIDE (TEMPORARY HOLD)
— Press or until the temperature you want is displayed. The thermostat will override current programming and keep the room temperature at the selected temperature for 2 hours or until the next program period begins. Then the thermostat will automatically revert to the program.
If you want to change the preprogrammed times and temperatures, follow these steps.
Determine the time periods and temperatures for your program.
You must program four periods for each day. However, you may use the same heating and cooling temperatures for consecutive time periods. You can choose start times, heating temperatures, and cooling temperatures independently (for example, you may select 5:00 AM and 70° as the weekday 1st
period heating start time and temperature, and also choose
7:00 AM and 76° as the weekday 1st period cooling start time and temperature).
Use the table to plan your program time periods and the temperatures you want during each period. Fill in the complete table to have a record of your programs.
Entering Your Program
Set Current Time and Day
1. Press TIME button once. The display will show the hour only.
EXAMPLE:
PROGRAMMING YOUR THERMOSTAT
This section will help you plan your thermostat’s program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.
Planning Your Program
Look at the factory preprogrammed times and temperatures shown in the sample schedule. If this program will suit your needs, simply press the RUN/HOLD button to begin running the factory preset program.
2. Press and hold either or until you reach the correct hour and AM/PM designation ( AM begins at midnight; PM begins at noon).
3. Press TIME once again. The display window will show the minutes only.
EXAMPLE:
• When heating (cooling) your building, program the temperatures to be cooler (warmer) when the building is vacant or during periods of low activity.
• During early morning hours, the need for cooling is usually minimal.
4. Press and hold either or until you reach the correct minutes.
5. Press TIME once again. The display will show the day of the week.
6. Press week.
or until you reach the current day of the
7. Press RUN/HOLD once. The display will show the correct time, day, room temperature and set-point temperature.
SAMPLE
Heating/Cooling Schedule Plan (Factory Program)
Period
WEEKDAYS
(5 Day)
Start
Time Temp
SATURDAY
(1 Day)
Start
Time Temp
SUNDAY
(1 Day)
Start
Time Temp
1ST 6:00 AM 70 °F 6:00 AM 70 °F 6:00 AM 70 °F
2ND
3RD
8:00 AM
5:00 PM
62
70
°F
°F
8:00 AM
5:00 PM
62 °F
70 °F
8:00 AM
5:00 PM
62
70
°F
°F
4TH
1ST
2ND
3RD
4TH
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
62
78
85
78
82
°F
°F
°F
°F
°F
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
62 °F
78 °F
85 °F
78 °F
82 °F
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
62 °F
78 °F
85 °F
78 °F
82 °F
Period
1ST
2ND
3RD
4TH
1ST
2ND
3RD
4TH
Heating/Cooling Schedule Plan
WEEKDAYS
(5 Day)
Start
Time Temp
SATURDAY
(1 Day)
Start
Time Temp
SUNDAY
(1 Day)
Start
Time Temp
7
PROGRAMMING
Enter Heating Program
1. Move the SYSTEM switch to HEAT.
2. Press PRGM once. “Mo Tu We Th Fr” (indicating weekday program) will appear in the display. Also displayed are the currently programmed start time for the 1st heating period and the currently programmed temperature (flashing).
EXAMPLE:
This display window shows that for the 1st weekday period, the start time is 6:00 AM, and 70° is the programmed temperature (this example reflects factory preprogramming).
3. Press or to change the displayed temperature to your selected temperature for the 1st heating program period.
4. Press TIME once (the programmed time will flash). Press
or until your selected time appears. The time will change in 15 minute increments. When your selected time is displayed, press TIME again to return to the change temperature mode.
5. Press PRGM once. The currently programmed start time and setpoint temperature for the 2nd heating program period will appear.
6. Repeat steps 3 and 4 to select the start time and heating temperature for the 2nd heating program period.
7. Repeat steps 3 through 5 for the 3rd and 4th heating program periods.
8. Press PRGM once. “SA” (indicating Saturday program) will appear in the display, along with the start time for the 1st heating period and the currently programmed temperature.
9. Repeat steps 3 through 7 to complete Saturday heating programming.
10. Press PRGM once to change to SU (Sunday) heating programming and repeat steps 3 through 7 to complete
Sunday programming.
11. When you have completed entering your heating program, press RUN/HOLD.
Enter Cooling Program
!
CAUTION
If the outside temperature is below 50 o F, disconnect power to the cooling system before programming.
Energizing the air conditioner compressor during cold weather may cause personal injury or property damage.
1. Move SYSTEM switch to COOL position.
2. Follow Enter Heating Program for entering your cooling program, using your selected cooling times and temperature.
CHECK YOUR PROGRAMMING
Follow these steps to check your thermostat programming one final time before beginning thermostat operation.
1. Move SYSTEM switch to HEAT position.
2. Press PRGM to view the 1st weekday heating period time and temperature. Each time you press PRGM, the next heating period time and temperature will be displayed in sequence for weekday, then Saturday and Sunday program periods (you may change any time or temperature during this procedure).
3. Press RUN/HOLD.
4. Move SYSTEM switch to COOL position.
5. Repeat step 2 to check cooling program.
6. Move SYSTEM switch to HEAT or COOL and press RUN/
HOLD to begin program operation.
YOUR THERMOSTAT IS NOW PROGRAMMED AND READY TO
PROVIDE MAXIMUM COMFORT AND EFFICIENCY!
8
TROUBLESHOOTING
Reset Operation
If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, reset the thermostat by pressing the , and PRGM buttons simultaneously. If the thermostat has power, has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.
Symptom
No Heat/No Cool/No Fan
(common problems)
No Heat
No Cool
Heat, Cool or Fan Runs
Constantly
Furnace Cycles Too Fast or Too Slow (narrow or wide temperature swing)
Cooling Cycles Too Fast or Too Slow (narrow or wide temperature swing)
Thermostat Setting and
Thermometer Disagree
Clock Loses or Gains
Time
Possible Cause
1. Blown fuse or tripped circuit breaker.
2. Furnace power switch to OFF.
3. Furnace blower compartment door or
panel loose or not properly installed.
1. System Switch not set to Heat.
1. Loss of power to thermostat.
Heat or Cool Starts Early 1. EMR activated.
Thermostat Does Not
Follow Program
1. AM or PM set incorrectly in program.
2. AM or PM set incorrectly on the clock.
3. Voltage spike or static discharge.
4. See “Heat or Cool Starts Early” above.
Blank Display and/or
Keypad Not Responding
1. Voltage Spike or Static Discharge.
Thermostat has HP/SS switch and Configuration
Menu has selection for
HP or SS
1. Earlier version of thermostat model.
9
Corrective Action
Replace fuse or reset breaker.
Turn switch to ON.
Replace door panel in proper position to engage safety interlock or door switch.
Set System Switch to Heat and raise setpoint above room temperature.
Verify thermostat and system wires are securely attached.
2. Loose connection to thermostat or
system
3. Heating System requires service or
thermostat requires replacement.
1. System Switch not set to Cool.
2. Loose connection to thermostat or
system.
3. Cooling System requires service or
thermostat requires replacement
1. Possible short in wiring.
2. Possible short in thermostat.
3. Possible short in Heat/Cool/Fan
system.
4. Fan Switch set to Fan On.
1. The location of the thermostat and/or
the size of the Heating System may be
influencing the cycle rate.
1. The location of the thermostat and/or
size of the Cooling System may be
influencing the cycle rate.
1. Thermostat thermometer setting
requires adjustment.
Diagnostic: Set System Switch to Heat and raise the setpoint above room temperature. Within a five minutes the thermostat should make a soft slick sound. This sound usually indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation listed above. If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a service person to verify the heating system is operating correctly.
Set System Switch to Cool and lower setpoint below room temperature.
Verify thermostat and system wires are securely attached.
Same procedures as diagnostic for No Heat condition except set the thermostat to Cool and lower the setpoint below the room temperature. There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock-out option is selected in the configuration menu (Item 6).
Check each wire connection to verify they are not shorted or touching together. No bare wire should stick out from under terminal screws. Try resetting the thermostat as described below. If the condition persists, the manufacturer of your system or service person can instruct you on how to test the Heat/Cool/ system for correct operation. If the system operates correctly, replace the thermostat.
Item 4 in the Configuration Menu is the adjustment that controls the cycle rate. If an acceptable cycle rate is not achieved using the FA (Fast) or SL (Slow) adjustment contact a local service person for additional suggestions.
The cycle rate for cooling is fixed and can not be adjusted.
Contact a local service person for suggestions.
The thermometer can be adjusted +/-4 degrees as listed in item 8 of the Configuration Menu. No other adjustment is possible.
The thermostat will maintain its program in memory even with no power but the clock time will be incorrect when power is restored. See No Heat/No Cool/No Fan (common problems) above for items to check in the system.
See Configuration Menu (Item 3).
Check current clock and program settings including the AM or PM designations for each time period. If a voltage spike or static discharge occurs use the Reset Operation listed above.
If a voltage spike or static discharge occurs use the Reset
Operation listed above.
If switch is present, it must be in HP position for proper fan operation. If selection appears in Configuration Menu, it must be set for HP.
TROUBLESHOOTING
STAGING
Second Stage - Auxiliary Heat
Most heat pump systems have an Auxiliary or Second Stage electric heater or gas furnace. Heat produced by a heat pump is economical but may not always have the capacity to maintain a comfortable room temperature setting. Auxiliary/Second
Stage heat is usually less economical but the added heat capacity assures the system can provide enough heat to satisfy the thermostat setting. Digital thermostats have a built-in function that computes the optimum time (approximately 0-30 minutes) to use Auxiliary / Second Stage heat in addition to the
Heat Pump heat.
Typical operation:
In moderate weather with a low temperature setting (low demand) the thermostat may use only the heat pump to maintain temperature.
In colder weather or higher temperature settings (higher demand) Auxiliary Heat is used occasionally to supplement the heat pump.
In very cold weather (very high demand) when Heat Pump performance is low Auxiliary Heat is used frequently to maintain comfort.
The thermostat automatically adjusts to optimize comfort and economy using the lowest stage practical to make setpoint.
The key to reducing energy costs and minimizing Auxiliary or
Second Stage is to set the thermostat to the lowest comfortable heating temperature.
10
NOTES
11
White-Rodgers is a division of Emerson Electric Co.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
Homeowner Help Line: 1-800-284-2925