Agilent Technologies 53152A is a high-performance microwave counter that offers exceptional sensitivity, accuracy, and versatility. With its ultrawide frequency range of 50 MHz to 46 GHz, it can measure the frequency and power of signals across the entire RF and microwave spectrum. It features simultaneous power and frequency measurement with an analog peaking indicator, making it easy to identify and measure signals. The built-in single connection simplifies testing and eliminates the need for multiple connections.
advertisement
Ihr Spezialist für
Mess- und Prüfgeräte
Full-featured CW Microwave Counters for Field, Factory or Lab
Product Overview
Agilent 53150A 20 GHz Counter
Agilent 53151A 26.5 GHz Counter
Agilent 53152A 46 GHz Counter
High performance microwave counters: at home, in the field, bench or ATE environment
• Ultrawide range, single input
(from 50 MHz up to 46 GHz)
• Simultaneous power and frequency measurement with analog peaking indicator
• GPIB and RS-232 standard
• Lightweight and rugged
• Battery optional
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ [email protected] ▪ www.datatec.de
Convenience, portability and outstanding performance
The innovative designs of the
Agilent 53150 Series microwave counters offer an uncluttered, featureladen front panel. These designs present no-compromise performance and quality in a surprisingly small, light, battery operated product.
The convenience of a single microwave input
The Agilent 53150 Series has an advanced sampler that integrates a separate zero bias Schottky diode for the accurate measurement of input power. This allows measurement of both frequency and power with a single connection. No compromise in frequency coverage is required for this capability. The ultrawideband microwave input covers the entire
RF and microwave spectrum, from intermediate frequencies IFs) of
50 MHz to millimeter waves.
The power measurement accuracy and repeatability of these counters rivals power meters with diode sensors. Since frequency and power of the input signal are measured simultaneously, adjustment for the diode’s frequency response is done automatically. And like the latest in diode sensors, compensation is also made for deviation from square law.
Field tough but ready for benchtop or ATE applications
The Agilent 53150 Series is as comfortable in the field as in the laboratory.
The rugged case with an integrated tilting handle can tolerate the vibration and shock expected in field use.
The backlit LCD display ensures visibility in all environments, from dark to full sunlight, at distances exceeding 15 feet.
If AC power is unavailable, the internal, replaceable camcorder batteries provide at least 2.5 hours of continuous operation. The unit can also be powered from an external 11-18 VDC source.
For benchtop and ATE applications, the Agilent 53150 Series delivers full functionality and high measurement speed. The fully programmable
RS-232 interface and high speed
GPIB interface are standard features.
No compromise performance
The Agilent 53150 Series offers exceptional sensitivity by utilizing a single board design with low phase noise PLL circuitry. Despite their simple appearance, these counters retain all the powerful functions one expects in precision instrumentation: measurement averaging, arbitrary as well as nulling offsets for both frequency and power, display of power in either dBm or Watts.
Additional capabilities include full control of resolution, sampling rate, and GPIB address, plus extensive self-diagnostics, fast acquisition times and full programmability.
Performance surpasses the industry standard Agilent 5350 Series, in virtually every aspect, in a package less than half the weight and size.
2
2 dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ [email protected] ▪ www.datatec.de
Measurement Specifications and Characteristics
All measurement specifications are over the full signal and temperature ranges unless otherwise noted.
Input characteristics
Frequency range
Channel 1 (Normal mode)
(Low pass filter enabled)
Channel 2
Sensitivity
Channel 1
10-30 Hz
30 Hz-125 MHz
Channel 2
50-300 MHz
0.3-12.4 GHz
12.4-18 GHz
18-20 GHz
20-26.5 GHz
26.5-40 GHz
40-46 GHz
Maximum input
Channel 1
Channel 2
50 MHz - 2 GHz
2-46 GHz
Damage level
Channel 1
Channel 2
Impedance (Nominal)
Channel 1
Channel 2
Connector
Channel 1
Channel 2
Agilent 53150A
10 Hz - 125 MHz
10 Hz - 50 kHz
50 MHz - 20 GHz
40 mVrms
25 mVrms
–20 dBm
–33 dBm
–33 dBm
–29 dBm
N/A
N/A
N/A
2 Vrms
+5 dBm
+13 dBm
120 V (DC + AC pk) linearly derated to 5 Vrms at 125 MHz
+27 dBm
1 MΩ/60 pF
50 Ω
BNC female
SMA/APC-3.5 compatible female
Agilent 53151A
10 Hz - 125 MHz
10 Hz - 50 kHz
50 MHz - 26.5 GHz
40 mVrms
25 mVrms
–20 dBm
–33 dBm
–33 dBm
–29 dBm
–25 dBm
N/A
N/A
2 Vrms
+5 dBm
+13 dBm
120 V (DC + AC pk) linearly derated to 5 Vrms at 125 MHz
+27 dBm
1 MΩ/60 pF
50 Ω
BNC female
SMA/APC-3.5 compatible female
Agilent 53152A
10 Hz - 125 MHz
10 Hz - 50 kHz
50 MHz - 46 GHz
40 mVrms
25 mVrms
–20 dBm
–33 dBm
–30 dBm
–27 dBm
–27 dBm
–23 dBm
–17 dBm
2 Vrms
+5 dBm
+13 dBm
120 V (DC + AC pk) linearly derated to 5 Vrms at 125 MHz
+27 dBm
1 MΩ/60 pF
50 Ω
BNC female
2.92 mm removable,
SMA/APC-3.5 compatible female
SWR (Typical)
Channel 2
50-300 MHz
0.3-10 GHz
10-20 GHz
20-26.5 GHz
26.5-46 GHz
Coupling
Channel 1
Channel 2
Emissions (Typical)
(“kickback noise“)
Channel 1
Channel 2 (measuring/no input)
Resolution
Channel 1/Channel 2
1.5:1 typical
2.0:1 typical
3.0:1 typical
N/A
N/A
AC
AC
N/A
–40 dBm/< –70 dBm
1 Hz to 1 MHz
1.5:1 typical
2.0:1 typical
3.0:1 typical
3.0:1 typical
N/A
AC
AC
N/A
–40 dBm/< –70 dBm
1 Hz to 1 MHz
1.5:1 typical
2.0:1 typical
3.0:1 typical
2.5:1 typical
2.5:1 typical
AC
AC
N/A
–40 dBm/< –70 dBm
1 Hz to 1 MHz
3
3 dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ [email protected] ▪ www.datatec.de
Measurement Specifications and Characteristics
Continued...
Input characteristics
Accuracy
Channel 1/Channel 2
(LSD = resolution selection)
Residual stability*
Channel 1
Channel 2
*Counter and source tied to same timebase
Measurement time (Typical)
Channel 1
Channel 2
Agilent 53150A
±1 LSD ± residual stability
±(timebase error x frequency)
N/A
0.6 LSD rms
1/Resolution + 20 ms
1/Resolution +
Acquisition time + 20 ms
Acquisition time (Typical)
(1 MHz FM rate, power measurement off)
Channel 1
Channel 2 (FM Auto/FM Off)
FM tolerance
Channel 1
Channel 2 (FM Auto)
(FM Off)
AM tolerance
Channel 1, Channel 2
N/A
125 ms/100 ms
N/A
20 MHz p-p max @ 10 MHz rate
1 MHz p-p @ 10 MHz rate
Any index provided minimum signal level is not less than sensitivity
Amplitude discrimination
Channel 1
Channel 2
below 300 MHz
above 300 MHz
Agilent 53151A
±1 LSD ± residual stability
±(timebase error x frequency)
N/A
0.8 LSD rms
1/Resolution + 20 ms
1/Resolution +
Acquisition time + 20 ms
N/A
125 ms/100 ms
N/A
20 MHz p-p max @ 10 MHz rate
1 MHz p-p @ 10 MHz rate
Any index provided minimum signal level is not less than sensitivity
Agilent 53152A
±1 LSD ± residual stability
±(timebase error x frequency)
N/A
1.25 LSD rms
1/Resolution + 20 ms
1/Resolution +
Acquisition time + 20 ms
N/A
140 ms/115 ms
N/A
20 MHz p-p max to 26.5 GHz,
12 MHz p-p max above 26.5 GHz
@ 10 MHz rate
1 MHz p-p @ 10 MHz rate
Any index provided minimum signal level is not less than sensitivity
N/A
N/A
Automatically measures the largest signal present provided signal is > 10 dB(typical) above any signal separated by less than 75 MHz;
> 20 dB (typical) above any signal separated by more than 75 MHz
N/A
N/A
Automatically measures the largest signal present provided signal is > 10 dB(typical) above any signal separated by less than 75 MHz;
> 20 dB (typical) above any signal separated by more than 75 MHz
N/A
N/A
Automatically measures the largest signal present provided signal is > 10 dB(typical) above any signal separated by less than 75 MHz;
> 20 dB (typical) above any signal separated by more than 75 MHz
Power measurement
Channel 1
Channel 2
Range
Accuracy at input connector**
(0 dBm to –20 dBm)
0.05-12.4 GHz
12.4-20 GHz
20-26.5 GHz
26.5-46 GHz
Resolution
Display
**see graphs for typical data
N/A
Counter sensitivity to +7 dBm
±1.5 dB
±1.5 dB
N/A
N/A
0.01 dB dBm or millwatts/microwatts
N/A
Counter sensitivity to +7 dBm
±1.5 dB
±1.5 dB
±2.0 dB
N/A
0.01 dB dBm or millwatts/microwatts
N/A
Counter sensitivity to +7 dBm
±1.0 dB
±1.5 dB
±1.5 dB
±2.0 dB
0.01 dB dBm or millwatts/microwatts
4
4 dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ [email protected] ▪ www.datatec.de
Typical* power measurement uncertainty at 25 °C for various input levels
*Typical means approximately 2/3 of all units will meet these characteristics.
0.4
0.3
0.2
0.6
0.5
0.8
0.7
Agilent 53150A/151A
Agilent 53152A
0.1
0
0.25 1 2 4 6 8 10 12 14 16 18 20 22 26.5 30 35 40 46
Frequency in GHz
Figure 1. –10 dBm input level at 25 °C
0.6
0.5
0.4
0.8
0.7
0.3
0.2
0.1
Agilent 53150A/151A
Agilent 53152A
0
0.25 1 2 4 6 8 10 12 14 16 18 20 22 26.5 30 35 40 46
Frequency in GHz
Figure 2. 0 dBm and –20 dBm input level at 25 °C
5
5 dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ [email protected] ▪ www.datatec.de
Typical* power measurement uncertainty at –25 dBm input level
*Typical means approximately 2/3 of all units will meet these characteristics.
0.9
1
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0.25 1 2 4 6 8 10 12 14 16
Frequency in GHz
Agilent 53150A/151A
Agilent 53152A
18 20 22 26.5
Figure 3. –25 dBm input level at 25 °C
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0.25 1 2 4 6 8 10 12 14 16
Frequency in GHz
Agilent 53150A/151A
Agilent 53152A
18 20 22 26.5
Figure 4. –25 dBm input level from 0 to 55 °C
6
6 dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ [email protected] ▪ www.datatec.de
Timebase
Frequency: 10 MHz
Output: 10 MHz sine wave, 1 Vrms into
50 Ω
External timebase input: 1, 2, 5, 10 MHz;
1 to 5 Vrms into 50 Ω
Connector: BNC female located on rear panel
Internal timebase stability
TCXO
(Standard)
Oven
(Option 001)
Aging rate
Per day — < 5 x 10 –10
Per month < 1 x 10 –7 < 1.5 x 10 –8
Short term
(1 s avg. time)
< 1 x 10 –9 < 2 x 10 –10
Line variation < 1 x 10 –7 < 1 x 10 –10
(±10%)
Warm-up — < 1 x 10 –8 within 5 min. after turn-on at 25 °C
Temperature stability (0-55 °C) < 1 x 10 –6 < 1 x 10 –8
General information
Save and recall: Up to 9 complete instrument setups may be saved and later recalled. These setups are retained when power is removed.
Sample rate: User-selectable
Fast (nominally 20 ms between readings), Medium (nominally
250 ms between readings), Slow
(nominally 1 s between readings) and Hold.
Self test: Internal memory and count circuitry automatically tested at startup, via menu selection, or remotely. Error messages displayed to indicate failed tests.
Size: 213 mm W x 88.5 mm H x 300 mm D
Operating temperature: 0-55 °C
With battery option: 0-40 °C
Weight: 4 kg without battery option,
6.4 kg with battery option
Warranty: 1 year
Programming: GPIB (IEEE-488.1-1987,
IEEE 488.2-1987) or RS-232C
Language: SCPI-1992.0 (Standard
Commands for Programmable
Instruments)
RS-232C rates: User-selectable 2400 to 19200 baud
Power supply:
AC : 90-132 Vac; 47.5-66 Hz or 360-
440 Hz 216-264 Vac; 47.5-66 Hz
line selection: automatic
power requirements: 75 VA max.
(25 W typ.)
DC: (Option 002 only): 11-18 Vdc;
2A max.
Battery (Option 002):
Type: VHS camcorder, lead acid
(2 each)
Charge time: 8 hours in unit
Capacity: 2.5 hours min. at 25 °C
Math functions:
Offset: Last reading and/or
entered offset to reading for either
power or frequency
Averaging: 1 to 99 measurement
running average
Cable loss compensation: Offsets
power reading via linear
interpolation of user-entered
attenuations with up to 9
independent frequency points.
Display: Backlit LCD. Backlight can be turned on or off via front panel control.
Sleep mode (Option 002 only):
Automatically activated if no input is present for 5 minutes.
Safety: Designed in compliance with
IEC-1010, CAN/CSA 1010.1
EMC: Designed in compliance with
IEC-11, EN50082-1, IEC801-2, -3, -4.
Accessories supplied
Operating, programming, and service manuals and AC power cord.
Ordering information
Agilent 53150A
Agilent 53151A
Agilent 53152A
20 GHz counter
26.5 GHz counter
46 GHz counter
Options
Option 001 Oven Timebase
Option 002 Battery and DC input
Option 1CM (53150-67001) Rackmount kit
53153A (Option 007) Soft carrying case for
5315xA microwave counters
Option A6J ANSI 7540 Compliant
Calibration
Option W30 Three years of Return Repair
Service
Service
7
7 dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ [email protected] ▪ www.datatec.de
Ihr Spezialist für
Mess- und Prüfgeräte
STARKE MARKEN. HÖCHSTE PRODUKTVIELFALT. BESTE QUALITÄT.
Schnell und bequem online bestellen – bei dataTec ist das möglich. Bei uns finden Sie die perfekte Lösung für ihre vielfältigen Anforderungen.
Wir bieten eine unschlagbare Auswahl an Mess- und Prüfgeräten namhafter Hersteller. Diese reicht von
Arbiträr-Funktionsgeneratoren über Logikanalysatoren bis hin zu Stromversorgungen und Stromzangen oder Oszilloskopen bis 90 GHz Bandbreite. Hohe Lagerkapazität und kurze Wege sorgen dafür, dass die gewünschte Ware ganz schnell bei Ihnen ist. Bundesweit meist innerhalb eines Tages.
Mehr Klicks, mehr Vorteile:
mehrere tausend Mess- und Prüfgeräte
tagesaktuelle Preise und Promotions
Warenkorbrabatt bei Onlinebestellung
versandkostenfrei*
Datenblatt-Download
u. v. m.
Angebotsanfrage oder Bestellung unter:
B2B-
ONLINE
SHOP
-
* ab € 80,- Auftragswert
SHOP
B2B-
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ [email protected] ▪ www.datatec.de
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project