Centurion D2 Turbo Low-Voltage Installation guide
Add to my manuals
9 Pages
Centurion D2 Turbo Low-Voltage is a 12V DC battery operated unit capable of moving gates weighing up to 250kg. It features a maximum speed of 24 meters per minute and can automate gates up to 10 meters in length. The D2 Turbo has built-in safety features such as automatic reverse on obstruction and adjustable auto-close time. It also allows for easy programming of remote controls and other input devices. With its durable construction and simple installation process, the D2 Turbo is a reliable and convenient choice for automating domestic sliding gates.
advertisement
D2 Turbo Pocket mechanical installation guide
TM
DOMESTIC
SLIDING GATE
OPERATOR
This guide is designed specifically for installers who are familiar with the installation of standard sliding gate motors, but do not know the specifics of the D2 Turbo.
Please do not proceed with the installation until you have read and fully understand the Safety instructions included in your product packaging. The Safety instructions are also available on www.centsys.co.za, and may also be obtained by contacting Centurion Systems on +27 860 236 887
(SA only).
This icon indicates tips and other information that could be useful during the installation.
This icon denotes variations and other aspects that should be considered during installation.
This icon indicates a warning, caution or attention!
Please take special note of critical aspects that MUST be adhered to in order to prevent injury.
The D2 Turbo domestic sliding gate operator has been designed solely to open and close domestic sliding gates. It must not be installed or used to automate the entrances of townhouse complexes, housing estates, industrial sites, etc.
It is a 12V DC battery operated unit with the following limitations:
Gate mass maximum:
Starting pull force:
Rated running force:
Maximum speed:
Maximum gate length:
Design life:
250kg
< 18kgf
< 9kgf
24 metres/minute
10 metres
Ten years at ten cycles per day
1
2
3
4
5
10
11
Which bit is what?
1. Motor fuse
2. Motor enclosure unit
3. Camlock cover
4. Release thumbwheel
5. Foundation plate
6. D2 Turbo controller
7. 12V 7.2Ah or 5Ah battery
8. Battery strap
9. Pulley guard
10. Gate mounted origin marker
11. Origin marker bracket
6
7
8
9
8
7
6
8
3
1
2
5
4
Legend
1. 10V - 24V AC or 10V - 28V DC supply cable via step-down transformer (mounted in house/dwelling) (2 core cabtyre or twinflex, thickness depending on distance of cable run and transformer output voltage. Refer to Cable Thickness Table in the User Guide
Optional wiring (all cable is multi-stranded):
5. TRG: Access control device (3 core 0.5mm )
6. PED: Optional pedestrian keyswitch (a)
2
7. TRG:
or keypad (b) (3 core 0.5mm )
Optional external radio receiver (3 core 0.5mm )
8. LIGHT: Optional pillar lights (3 core LNE SWA, size according to power requirements) n1 = number of cores required by intercom n2 = number of cores required by intercom
Possibly increase cable thickness if pillar lights are installed
Allows for all features such as pedestrian opening, status LED, etc., to be operated from the intercom handset inside the dwelling.
Number of cores and type of cable could vary depending on brand of access control system being used
For optimum range, an external receiver can be mounted on the wall
Ensure that all the standard considerations for a quality gate installation are adhered to as specified in Centurion
Systems’ comprehensive installation manuals. If you are unfamiliar with these, then you may find them on
www.CentSys.com. However, as a minimum please ensure that:
There is unobstructed access in and out of the premises
The operator must not protrude into the driveway
Endstops are mandatory and must be capable of stopping the gate at rated speed
Guide-rollers and anti-lift brackets are correctly fitted
The specified gate mass, starting- and rated-pull-force limitations are not exceeded
All relevant safety instructions are adhered to
Mount the operator
8A. Selecting Manual Mode
8A.1. Insert the camlock key and rotate it 90°
clockwise. This will allow for the removal of the cover, as well as for the rotation of the Manual
Release thumbwheel.
8A.2. The motor pinion can be put into ‘Manual Mode’
(unlocked) by rotating the
Manual Release thumbwheel counter-
clockwise through approximately 90°.
Using the camlock, it is possible to lock the operator cover in place with the Manual Release thumbwheel in either the ‘locked’ or ‘unlocked’ position
When locked, the Manual Release thumbwheel cannot be moved from ‘locked’ to ‘unlocked’ or vice versa
8B. Locate entry points for conduits/cables
8B.1. Cable entry is allowed for on the far left hand side corner of the gearbox.
Cable entry points
Mounting studs
8B.2. Fit the mounting studs to the foundation plate and secure in place with the stud locknuts.
Foundation plate
Level this end of the rack, and fix
Stud locknut
(M10 half-height nut)
8B.3. Position the foundation plate to allow for the pinion to be unmeshed from the rack when the gearbox has to be removed.
Leave clearance under the gearbox to allow for the gearbox to be lowered if the rack and pinion mesh is too tight.
Check that the rack is just resting on the pinion
Level this end and fix
3mm tooth gap
A gap of 3mm between the rack and the pinion must be maintained.
3mm
Lower
8B.4. Fit RAZ/Nylon/Steel angle rack as recommended by Centurion
Systems. Use height-adjustment nuts to obtain correct rack and pinion mesh. Rack can be mounted above or below the pinion to suit site conditions. Refer to illustration A1, A2, A3, B1, B2 and B2.
A1: Above pinion - RAZ rack A2: Below pinion - RAZ rack
148 - 158
Foundation plate
Flat bar welded to foundation plate and rail
* Includes 3mm clearance required between rack and pinion
B1: Above pinion - Nylon rack
Raised foundation
148 - 158
Foundation plate
B2: Below pinion - Nylon rack
148 - 158
Foundation plate
Flat bar welded to foundation plate and rail
* Includes 3mm clearance required between rack and pinion
C1: Above pinion - Steel rack
Raised foundation
148 - 158
Foundation plate
C2: Below pinion - Steel rack
146
Foundation plate
Flat bar welded to foundation plate and rail
* Includes 3mm clearance required between rack and pinion
Raised foundation
146
Foundation plate
The pinion guard is easily removed and rotated allowing the rack to be fitted above or below the pinion.
8B.5. Use the orange heightadjustment nuts provided to level the gearbox.
8B.6. Tighten the hold-down nuts when the gearbox is in the correct position.
Holddown nuts
(M10
nuts)
Orange heightadjustment nuts
Washer
Stud locknut (M10 half-height nut)
Theft-resistant
nut and Discus
padlock are available from
CENTURION for sites requiring additional security.
Discus padlock
C: Isometric view
Theftresistant nut
8B.7. Mount gate origin marker to rack as per illustration C, D and E, with the gate in the closed position.
Greater than 500mm
D: Plan view
Greater than 500mm
Origin marker
Gate in closed
position
E: Plan view
Take care with the orientation of the arrow on the origin marker. This arrow must face the operator.
10-17mm
Origin sensor inside motor enclosure
Origin marker
Gate
Rack
Unclip orange battery clip
8B.8. Battery is fitted between the motor enclosure
unit and the D2 Turbo controller.
8B.9. Unclip the orange clips holding the controller onto the motor enclosure unit.
8B.10. Fit the 7.2Ah/5Ah battery and clip the orange clips down to secure the battery in place.
Fit the
7Ah/5Ah battery
Clip orange battery clip to secure
9.1. Always check that the circuit breaker in the electrical panel is in the OFF position, and that all high voltage circuits (more than 42.4V) are completely isolated from the mains supply before doing any work.
9.2. Ensure that all low voltage systems (less than 42.4V) are suitably protected from damage, by disconnecting all sources of power such as chargers and batteries before doing any work.
9.3. All electrical work must be carried out according to the requirements of all applicable local electrical codes. (It is recommended that a licensed electrical contractor perform such work.)
Connect all wiring
Wire the controller to the required input and output devices as per the wiring diagrams on the right hand side.
Refer to the illustration of the D2 Turbo controller, which shows the position of the Function and Setting Dials, the status LED, and the
select/toggle Pushbutton.
All programming is done by means of two rotary Dials, a Pushbutton, and the bi-colour (red and green) status LED.
The rotary Function Dial selects the required function you wish to set. This is selected first.
Secondly, the rotary Setting Dial dials in the actual setting for the function selected.
10A. Using the Pushbutton and status LEDs
To select a particular setting, press the pushbutton
The status LED indicates the status of the setting
A green status LED indicates that particular setting is selected
A red status LED indicates it is off or not selected
If the setting is a single fixed value, e.g. 15 second autoclose time, then the pushbutton acts as a select.
If the setting has an option such as On/Off, or Hi/Low then the pushbutton will act as a toggle.
If the status LED is green, then the first option is selected
If the status LED is red, then the second option is selected
10B. Using the Function Dial
The Function Dial has six different settings that may be selected:
RUN: Fully anti-clockwise. The unit must be left in this position for “Normal run” operation
A - LIMITS: Sets up the gate open and closed positions automatically.
B - REMOTES: Allows for NOVA remotes to be added or deleted
C - AUTOCLOSE: Allows for different Autoclose times to be set
D - MODE: Allows for different modes of operation to be set
E - PROFILE: Allows for specific gate profiles to be toggled
On/Off or Hi/Low
10C. Using the Setting Dial
The Setting Dial has six different positions, which allow the function required, to be selected.
Function dial
A - LIMITS
B - REMOTES
C - AUTOCLOSE
D - MODE
E - PROFILE
Setting dial (Ring position-Dial position)
A-1 Automatic; Start with gate closed
B-1 Learn a transmitter button to Trg
B-2 Learn a transmitter button to Ped
B-3 Learn a transmitter button to Lck
B-4 Delete a transmitter
B-5 Delete all transmitters
C-1 Autoclose off
C-2 Autoclose after 5 seconds
C-3 Autoclose after 10 seconds
C-4 Autoclose after 15 seconds
C-5 Autoclose after 30 seconds
C-6 Autoclose after 45 seconds
D-1 Standard Mode
D-2 Open Only Mode
D-3 Reversing Mode
D-4 PIRAC Mode On Off
D-5 Pre-Flash Mode A On Off
D-6 Pre-Flash Mode B On Off
E-1 Positive Close Mode
E-2 Speed
E-3 Sensitivity
Hi
Hi
Low
Low
E-4 Backup to Backup Memory Module
E-5 Restore from Backup Memory Module
Use toggle pushbutton to select preference.
For D - MODE, green status LED=On; red status LED=Off
For E - PROFILE, green status LED=High; red status LED=Low
PFA: The Pillar Light relay will activate for two seconds before gate movement occurs, as well as during gate movement.
This means gate movement will be delayed for a period of two seconds after a trigger has been received
PFB: The Pillar Light relay will only activate during gate movement
High Speed: Gate will operate at its maximum speed – typically 24 metres per minute
Low Speed: Gate will operate at 16 metres per minute
If Backup to Backup Memory Module or Restore from Backup Memory Module are required, remove ENCODER/ORIGIN connector and fit CP108 (Backup Memory Module)
Any controllers not marked with ‘BACKUP’ and ‘RESTORE’ do not support this function
E-4 and E-5 text is not screened on the BETA versions
110 - 220V
Mains in
E
N
L
Waterproof isolator enclosure within two metres of motor
CP106
Relay Card optional
To alarm panel, etc
Relay card
CP106
i5 Infrared safety beam (opening) optional, but recommended
Connection type: Normally closed
Rx
IRB Receiver
Tx
IRB Tx - Open
Pillar Light/
Courtesy Light optional
E
N
L
LIGHT
30A
ENCODER
ORIGIN
SETUP:
Step 1: Select FUNCTION
Step 2: Select SETTING
Step 3: Press
Step 4: When finished
select RUN
L
MI
TI
S
A
R
E
M
O T E S
B
AUTOCL
C
OSE
M
D
O
D
E
E
FUNCTION
Status LED
Aux 12V
Safe Com
Com
Safe OPN
Safe CLS
LCK/STP
TRG
PED
Aux I/O
Com
LED
A B C D E SETTING
OR
Improved lightning protection
POLOphone entry panel optional
Connection type: Normally open
1
2
-
NO
COM
POLOphone handset status LED optional
Connection type: Normally closed
For enhanced security, connect the entry panel to a POLOswitch at the operator
Holiday Lockout keyswich optional
Connection type: Normally closed; latching contact
Optional
Recommended
IRB Receiver
Rx
12V+
12V-
TRG
PED
NC
COM
6
7
4
5
8
9
1
2
3
Tx
IRB Tx - Close
Sharecall 0860-CENTURION (0860 236 887)
Head Office: +27 11 699 2400
Sharecall Technical Support 0861 003 123 or
+27 11 699 2481 from 07h00 to 18h00 (GMT+2)
(Sharecall numbers applicable when dialed from within South Africa only)
0.07.A.0095_05022014
www.centsys.com