GENERAL DESCRIPTION

The MD402-DMX is a 4-channel DMX-512 compatible dimmer pack. It is equivalent to four solid-state relays (SSR's) and a DMX512 Logic assembled on a single circuit board. Power is fed to the MD402-DMX from One 10 Amp. breaker

. Each solid state relay is rated for a maximum output current of 2.5 amperes.

The MD402-DMX has an open frame U shaped enclosure which also serves as a heat sink. The logic signals are optically-isolated from all line voltage elements.

For 120VAC and 220VAC applications an external step-down 8 to 12 VAC/ 300mA transformer is required to supply power to the Logic of the MD402-DMX ( not needed for low volatge applications )

.

The DMX-512 control cable is hardwired to the MD402-DMX. Several Dimmer packs may be daisy-chained together. Each MD402-DMX may be easily set to a unique address with 2 hexadecimal selectors and will occupy the next four DMX control channels beginning with the one following the address selected. When two or more units are set to the same address, their respective outputs work in unison, increasing the amount of load that can be controlled by a single DMX channel. Each of the MD402-DMX outputs may be independently configured not to dim. In such case, a DMX input value greater than 3 switches its respective output to 100%, else the output remains at 0%.

Figure 1 shows a functional block diagram of the MD402-DMX. Figure 2 shows

MD402-DMX dimmers in a typical installation.

DIMMING/SWITCHING - (See Page 10 for more information)

A MD402-DMX may control a combination of dimmed and switched loads. Each of the MD402-DMX’s outputs may be independently configured not to dim. This is achieved using a HARDWARE lock ( Jumper )to ensure circuits do not dim. Please see Page 10 for location of these jumpers.

There are no RFI chokes installed inside the unit. In environment sensitive to noise

, external chokes might be added by installer for noise filtering.

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402

-DMX Detail

MD402-DMX

4-Channel Dimmer Pack

User's Manual - Page 2

Figure 1 - MD402-DMX Detail

16

19

OUTPUT TERMINAL

H N N 1 2 3 4

17

15

6

11 12

5

2

3

1

S1 S2

S3

4

13 14

18

10

9

8

7

Table 1 - OUTPUT Terminals

Definition

NAME DESCRIPTION

4

H

N

1

2

3

Output Of Solid-State Relay #1

Output Of Solid-State Relay #2

Output Of Solid-State Relay #3

Output Of Solid-State Relay #4

Hot Line Feed For Relays 1 , 2 , 3 & 4.

Neutral Bus Connections.

Table 2 - Absolute Maximum

Electrical Ratings

Electrical Characteristic Terminal Maximum

Relay Load Current

Input Current

Input Voltage

1 to 4 2.5 Amps.

H 10 Amps.

H 120 VAC

Table 3 - MD402-DMX Circuit Legend

1

Microprocessor.

2

Not used

3

Communications Chip.

4

Quartz Crystal.

5

Power Supply Capacitor.

6

Voltage Regulator.

7

DMX512 DATA connector.

8

Logic power connector

9

Output LED Monitors.

10

Jumpers for switches only

11,12,13,14

15,16,17,18

19

Fuse 5mm

Optical Couplers # 1,2,3,4

Triacs # 1,2,3,4

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402-DMX

4-Channel Dimmer Pack

User's Manual - Page 3

Mechanical Installation

The MD402-DMX modules are designed to be mounted in NEMA enclosures( by others).

4.30"

Mounting hole

For # 6 screw

10 A.

Fuse

2

1

1

MD402-DMX

Optocouplers

3

2 3 4

DMX-D

V4.2

RS485

Communication

S2

Microprocessor

D

E

C

B

A

0

2

3

4

6

9

8

7

D

E

C

B

A

0

2

3

4

6

9

8

7

S1

High address

4

-

Mounting hole

For # 6 screw

Channel Indicators

1

9 VAC

D D +

Figure 3 - MD402-DMXDimensional Diagram

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402-DMX

MD402

-DMXLow Voltage Wiring Methods

Figure 4

MD Dimmer Network

Ports Connections.

4-Channel Dimmer Pack

User's Manual - Page 4

MD402-DMX

Buttom view

8 to 12 VAC / 200 MA

From transformer

Same phase as Hot

Input of MD402-DMX

For 120VAC and 220VAC applications only

- DATA +DATA

DMX512 Data

Figure 5 - Typical Installation

120VAC

To Loads

DMX CONTROL

EQUIPMENT

MD402

-DMX-120

9-12 VAC

*

Logic power

One twisted pair data

120VAC

To Loads

MD402

-DMX-120

9-12 VAC

*

Logic power

120VAC

To Loads

MD402

-DMX-120

9-12 VAC

*

Logic power

To more DMX

Equipment

*

The 9-10 V logic power is not needed in low voltage applications : 8-24V

The same Low voltage AC transformer could be used for the all MD402-DMX-120 connected to the same phase

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402-DMX

MD402-120VAC General Wiring Instructions

4-Channel Dimmer Pack

User's Manual - Page 5

Wiring Notes

0 DO NOT EXCEED 300 W (2.5 Amps. ) per dimmer output @ 120VAC.

0

All wiring between the controller and other dimmers (DATA bus) is low voltage (NEMA Class 2) and may be run with One, twisted pair, shielded #22 AWG wire.

0 MD402-DMXdimmer Modules may be fed by one 15 A (maximum) branch circuits and may have up to four separately dimmed loads.

0 CAUTION: DO NOT attempt to parallel outputs to increase capacity.

0

Installation must conform to local and/or NEC code requirements and must be performed by a qualified electrician.

0

All line voltage wires must have copper conductors of adequate Gauge with 90° C wire insulation.

0

POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE MD402-DMXTO ENSURE PROPER WIRING.

Figure 7 - MD402-DMX-120 Typical 120 VAC Wiring.

1x15 A - 120 VAC

Breaker

Electrical

Distribution Panel

HOT

INPUT

NEUT.

INPUT

HOT

NEUTRAL

1 2 3

4

Max. Per Load:

(300 W at 120 VAC).

C

AU

M

D4

TIO

N

02

-1

M od

20

V els

O

AC

NL

Y

10 A.

Fuse

2

1

MD402-DMX

Optocouplers

3

CAUTION:

Fuse1

10 Amps/250V ; quick blow

Disconnect Power

Before replacing

1

2 3 4

S2

DMX-D

V4.2

Microprocessor

E

F

0 1

2

3

6

B

9 A

8

7

RS485

Communication

S3

High address

B

E

F

0 1

2

3

6

9 A

8

7

S1

4

-

Channel Indicators

1

9 VAC

D D +

External Transformer from 8 VAC to 12 VAC for logic power and phase reference.

9 VAC 0.3 Amp

+ DATA

Twisted pair connects to other DMX512 components

DMX512 DATA BUS

- DATA

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

0308

Digital Lighting Systems

MD402-DMX

MD402-220/240VAC General Wiring Instructions

4-Channel Dimmer Pack

User's Manual - Page 6

Wiring Notes

0 DO NOT EXCEED 600 W (2.5 Amps. ) per dimmer output @ 240VAC.

0

All wiring between the controller and other dimmers (DATA bus) is low voltage (NEMA Class 2) and may be run with One, twisted pair, shielded #22 AWG wire.

0 MD402-DMXdimmer Modules may be fed by one 15 A (maximum) branch circuits and may have up to four separately dimmed loads.

0 CAUTION: DO NOT attempt to parallel outputs to increase capacity.

0

Installation must conform to local and/or NEC code requirements and must be performed by a qualified electrician.

0

All line voltage wires must have copper conductors of adequate Gauge with 90° C wire insulation.

0

POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE MD402-DMXTO ENSURE PROPER WIRING.

Figure 7 - MD402-DMX-240 Typical 220/240 VAC Wiring.

1x15 A - 220/240 VAC

Breaker

Electrical

Distribution Panel

HOT

INPUT

NEUT.

INPUT

HOT

NEUTRAL

1 2 3

4

Max. Per Load:

(600 W at 240 VAC).

M

D4

C

AU

02

TIO

N

-2

M

20

/2 els

O od

40

V

AC

NL

Y

10 A.

Fuse

2

1

MD402-DMX

Optocouplers

3

CAUTION:

Fuse1

10 Amps/250V ; quick blow

Disconnect Power

Before replacing

1

2 3 4

S2

DMX-D

V4.2

Microprocessor

E

F

0 1

2

3

6

B

9 A

8

7

RS485

Communication

S3

High address

B

E

F

0 1

2

3

6

9 A

8

7

S1

4

-

Channel Indicators

1

9 VAC

D D +

External Transformer from 8 VAC to 12 VAC for logic power and phase reference.

9 VAC 0.3 Amp

+ DATA

Twisted pair connects to other DMX512 components

DMX512 DATA BUS

- DATA

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402-DMX

4-Channel Dimmer Pack

User's Manual - Page 7

Figure 9 - MD402-24VAC/MD402-12VAC GENERAL WIRING INSTRUCTIONS:

Wiring Notes

0 DO NOT EXCEED 60W @ 24 VAC or 30 W @ 12 VAC (2.5 Amps. ) per dimmer output

0

All wiring between the controller and other dimmers (DATA bus) is low voltage (NEMA Class 2) and may be run with One, twisted pair, shielded #22 AWG wire.

0 MD402-DMXdimmer Modules may be fed by one 15 A (maximum) branch circuits and may have up to four separately dimmed loads.

0 CAUTION: DO NOT attempt to parallel outputs to increase capacity.

0

Installation must conform to local and/or NEC code requirements and must be performed by a qualified electrician.

0

All line voltage wires must have copper conductors of adequate Gauge with 90° C wire insulation.

0

POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE MD402-DMXTO ENSURE PROPER WIRING.

24 VAC

OR

12 VAC

C

M

D4

02

-2

AU

TIO

4V

AC

M od

N

/M

D4 els

02

-1

O

NL

Y

2V

AC

1 2 3 4

COMMON

10 A.

Fuse

2

MD402-DMX-xx

Optocouplers

3

1

-

1 2 3 4

S2

DMX-D

V4.2

Microprocessor

E

F

0

1

2

3

B

A 9

8

6

7

RS485

Communication

E

F

0

1

2

3

6

9 A

B

7

8

S1

S3

High address

4

CAUTION:

Fuse1

10 Amps/250V ; quick blow

Disconnect Power

Before replacing

Channel Indicators

1

D D +

+ DATA

Twisted pair connects to other DMX512 components

DMX512 DATA BUS

- DATA

NOTES

1 With MD402-24 you may use a single 24 VAC-250 VA or better transformer.

2 With MD402-12 you may use a single 12 VAC-150 VA or better transformer.

3 Follow transformer's installation & wiring instructions from manufacturer.

4 Maximum Load Per Output: 30 Watts at 12 VAC OR Maximum Load Per Output: 60 watts at 24 VAC.

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402-DMX

4-Channel Dimmer Pack

User's Manual - Page 8

Figure 9 - MD402-24VDC/MD402-12VDC GENERAL WIRING INSTRUCTIONS:

Wiring Notes

0 DO NOT EXCEED 60W @ 24 VDC or 30 W @ 12 VDC (2.5 Amps. ) per dimmer output

0

All wiring between the controller and other dimmers (DATA bus) is low voltage (NEMA Class 2) and may be run with One, twisted pair, shielded #22 AWG wire.

0 MD402-DMXdimmer Modules may be fed by one 15 A (maximum) branch circuits and may have up to four separately dimmed loads.

0 CAUTION: DO NOT attempt to parallel outputs to increase capacity.

0

Installation must conform to local and/or NEC code requirements and must be performed by a qualified electrician.

0

All line voltage wires must have copper conductors of adequate Gauge with 90° C wire insulation.

0

POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE MD402-DMXTO ENSURE PROPER WIRING.

POSITIVE

+

NEGATIVE

-

24 VDC

OR

12 VDC

+ +

COMMON

1 2 3 4

C

M

D4

02

-2

AU

TIO

N

4D

C

/M

D4

M od els

O

02

-1

2D

C

NL

Y

10 A.

Fuse

2

MD402-DMX-xxDC

Optocouplers

3

1

-

1 2 3 4

S2

DMX-D

V4.2

Microprocessor

E

F

0

1

2

3

B

A 9

8

6

7

RS485

Communication

E

F

0

1

2

3

6

9 A

B

7

8

S1

S3

High address

4

CAUTION:

Fuse1

10 Amps/250V ; quick blow

Disconnect Power

Before replacing

Channel Indicators

1

D D +

+ DATA

Twisted pair connects to other DMX512 components

DMX512 DATA BUS

- DATA

NOTES

1 With MD402-24 you may use a single 24 VAC-250 VA or better transformer.

2 With MD402-12 you may use a single 12 VAC-150 VA or better transformer.

3 Follow transformer's installation & wiring instructions from manufacturer.

4 Maximum Load Per Output: 30 Watts at 12 VAC OR Maximum Load Per Output: 60 watts at 24 VAC.

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402-DMX

4-Channel Dimmer Pack

User's Manual - Page 9

DMX Address Setting

Up to 128 MD402-DMX dimmer packs may be installed per system and their DMX input daisy-chained using standard DMX-512 cables. Different addresses ranging from 1 to 509 may be selected for each dimmer, depending on which DMX channel(s) will be used to control it. Each dimmer pack uses four consecutive DMX bytes from the input stream beginning at the address selected using rotary selectors S1, S2 and address expansion jumper S3.

(See Figure 3 on page 2 for selectors location).

The MD402-DMX is shipped from the factory with jumper S3 installed allowing a DMX address range between 1 and

256 to be selected by S1 & S2 (See Table 4). For higher addresses ( 257-509) jumper S3 must be removed (See

Table 5).

Non-Dim Output Setting

Any or all of the MD402-DMX outputs may be configured for non-dim (switch only) operation. This prevents inadvertent dimming, or damage, of loads that cannot be dimmed, such as contactors, mechanical relays, motors, non-dim fluorescent, etc...

Since this procedure involves adding external wire jumpers to the INT4 board, it is preferable to have it performed by the factory, at time of order. However, a qualified electronic technician can perform the procedure in the field when necessary. Figure 8 shows the location for installing the non-dim (ND) jumpers.

The numbers shown next to the ND jumpers represent the corresponding output number of the MD402-DMX.

Installing an ND jumper makes the corresponding output non-dim (switch only). A DMX value greater than 3 turns a non-dim output to full intensity. A DMX value of 3 or less turns it fully off.

BEFORE ENERGIZING THE MD402-DMX MAKE SURE:

0 Loads are tested before connecting to dimmers.

0 MD402-DMX has been properly grounded.

0

All line voltage screw terminals are properly tightened to prevent hot spots.

0 Low voltage data lines connections are properly insulated.

0 Low voltage data lines polarity is observed throughout the system.

0 The MD402-DMX is set to the right address.

MD402-DMX Installation Check List

HOT

NEUTRAL

1 2 3 4

10 A.

Fuse

2

1

-

1

MD402-DMX

Optocouplers

3

2 3 4

DMX-D

V4.2

S2

Microprocessor

B

E

F

0 1

2

3

A

8

9

6

7

B

E

F

0 1

2

3

A

8

9

6

7

RS485

Communication

S3

High address

S1

Channel Indicators

1

9 VAC

D D +

ND1

ND2

ND3

ND4

4

Address Expansion Jumper (S3)

S3 Installed (S2,S1) Address Range: 1-256

S3 Removed (S2,S1) Address Range: 257-509

Channel 4

Channel 3

Channel 2

Channel 1

Non-Dim Jumpers ND1-ND4

Installed Output Is Non-Dim (Switch Only)

Removed Normal Dimmer Output.

Unit is shipped without ND jumpers.

Figure 8

- MD402 Address & Mode Selection.

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402-DMX

4-Channel Dimmer Pack

User's Manual - Page 10

MD402-DMX Address Selection Information

Table 4 - Addresses 1-256

Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select

Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1

50

51

52

53

54

55

56

57

37

38

58 39

59 3A

60 3B

61 3C

31

32

33

34

35

36

62 3D

63 3E

64 3F

37

38

39

40

41

42

33

34

35

36

43 2A

44 2B

45 2C

46 2D

47 2E

48

49

2F

30

24

25

26

27

28

29

20

21

22

23

18

19

20

21

22

23

24

25

17

18

26 19

27 1A

28 1B

29 1C

11

12

13

14

15

16

30 1D

31 1E

32 1F

7

8

5

6

9

10

1

2

3

4

11 0A

12 0B

13 0C

14 0D

15 0E

16 0F

17 10

04

05

06

07

08

09

00

01

02

03

178 B1

179 B2

180 B3

181 B4

182 B5

183 B6

184 B7

185 B8

186 B9

187 BA

188 BB

189 BC

190 BD

191 BE

192 BF

161 A0

162 A1

163 A2

164 A3

165 A4

166 A5

167 A6

168 A7

169 A8

170 A9

171 AA

172 AB

173 AC

174 AD

175 AE

176 AF

177 B0

146 91

147 92

148 93

149 94

150 95

151 96

152 97

153 98

154 99

155 9A

156 9B

157 9C

158 9D

159 9E

160 9F

129 80

130 81

131 82

132 83

133 84

134 85

135 86

136 87

137 88

138 89

139 8A

140 8B

141 8C

142 8D

143 8E

144 8F

145 90

114 71

115 72

116 73

117 74

118 75

119 76

120 77

121 78

122 79

123 7A

124 7B

125 7C

126 7D

127 7E

128 7F

97

98

60

61

99 62

100 63

101 64

102 65

103 66

104 67

105 68

106 69

107 6A

108 6B

109 6C

110 6D

111 6E

112 6F

113 70

82 51

83 52

84 53

85 54

86 55

87 56

88 57

89 58

90 59

91 5A

92 5B

93 5C

94 5D

95 5E

96 5F

65 40

66 41

67 42

68 43

69 44

70 45

71 46

72 47

73 48

74 49

75 4A

76 4B

77 4C

78 4D

79 4E

80 4F

81 50

Table 4 - MD402-DMX Decimal to Hexadecimal Address Chart.

Address Selection Chart Using S2-S1 with JUMPER 3 INSTALLED

210 D1

211 D2

212 D3

213 D4

214 D5

215 D6

216 D7

217 D8

218 D9

219 DA

220 DB

221 DC

222 DD

223 DE

224 DF

193 C0

194 C1

195 C2

196 C3

197 C4

198 C5

199 C6

200 C7

201 C8

202 C9

203 CA

204 CB

205 CC

206 CD

207 CE

208 CF

209 D0

242 F1

243 F2

244 F3

245 F4

246 F5

247 F6

248 F7

249 F8

250 F9

251 FA

252 FB

253 FC

254 FD

255 FE

256 FF

225 E0

226 E1

227 E2

228 E3

229 E4

230 E5

231 E6

232 E7

233 E8

234 E9

235 EA

236 EB

237 EC

238 ED

239 EE

240 EF

241 F0

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

Digital Lighting Systems

MD402-DMX

4-Channel Dimmer Pack

User's Manual - Page 11

MD402-DMX Address Selection Information

Table 5 - Addresses 257-509

Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select

Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1 Addr.

S2 S1

306 31

307 32

308 33

309 34

310 35

311 36

312 37

313 38

314 39

315 3A

316 3B

317 3C

318 3D

319 3E

320 3F

289 20

290 21

291 22

292 23

293 24

294 25

295 26

296 27

297 28

298 29

299 2A

300 2B

301 2C

302 2D

303 2E

304 2F

305 30

274 11

275 12

276 13

277 14

278 15

279 16

280 17

281 18

282 19

283 1A

284 1B

285 1C

286 1D

287 1E

288 1F

257 00

258 01

259 02

260 03

261 04

262 05

263 06

264 07

265 08

266 09

267 0A

268 0B

269 0C

270 0D

271 0E

272 0F

273 10

434 B1

435 B2

436 B3

437 B4

438 B5

439 B6

440 B7

441 B8

442 B9

443 BA

444 BB

445 BC

446 BD

447 BE

448 BF

417 A0

418 A1

419 A2

420 A3

421 A4

422 A5

423 A6

424 A7

425 A8

426 A9

427 AA

428 AB

429 AC

430 AD

431 AE

432 AF

433 B0

402 91

403 92

404 93

405 94

406 95

407 96

408 97

409 98

410 99

411 9A

412 9B

413 9C

414 9D

415 9E

416 9F

385 80

386 81

387 82

388 83

389 84

390 85

391 86

392 87

393 88

394 89

395 8A

396 8B

397 8C

398 8D

399 8E

400 8F

401 90

370 71

371 72

372 73

373 74

374 75

375 76

376 77

377 78

378 79

379 7A

380 7B

381 7C

382 7D

383 7E

384 7F

353 60

354 61

355 62

356 63

357 64

358 65

359 66

360 67

361 68

362 69

363 6A

364 6B

365 6C

366 6D

367 6E

368 6F

369 70

338 51

339 52

340 53

341 54

342 55

343 56

344 57

345 58

346 59

347 5A

348 5B

349 5C

350 5D

351 5E

352 5F

321 40

322 41

323 42

324 43

325 44

326 45

327 46

328 47

329 48

330 49

331 4A

332 4B

333 4C

334 4D

335 4E

336 4F

337 50

Table 5 - MD402-DMX Decimal to Hexadecimal Address Chart.

Address Selection Chart Using S2-S1 with JUMPER 3 REMOVED

466 D1

467 D2

468 D3

469 D4

470 D5

471 D6

472 D7

473 D8

474 D9

475 DA

476 DB

477 DC

478 DD

479 DE

480 DF

449 C0

450 C1

451 C2

452 C3

453 C4

454 C5

455 C6

456 C7

457 C8

458 C9

459 CA

460 CB

461 CC

462 CD

463 CE

464 CF

465 D0

498 F1

499 F2

500 F3

501 F4

502 F5

503 F6

504 F7

505 F8

506 F9

507 FA

508 FB

509 FC

510 N/A

511 N/A

512 N/A

481 E0

482 E1

483 E2

484 E3

485 E4

486 E5

487 E6

488 E7

489 E8

490 E9

491 EA

492 EB

493 EC

494 ED

495 EE

496 EF

497 F0

12302 SW 128 Ct. Bay #105 Miami, FL 33186

Tel: 305-969-8442 Fax: 305-969-8675

Copyright 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.

MD402-DMX-UM

0308

LIMITED WARRANTY

Digital Lighting Systems, warrants to the purchaser that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended. Any abuse or misuse contrary to normal operation shall void this warranty.

Digital Lighting Systems' obligation under this warranty shall be limited to replacement or repair of any units as shall within two years of date of invoice from Digital Lighting Systems, prove defective; and Digital Lighting Systems shall not be liable for any other damages, whether direct or consequential. The

implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the

expressed warranty. Some states do not allow the exclusion of the limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, you may also have other legal rights which vary from state to state.

Defective merchandise may be returned to Digital Lighting

Systems, prepaid, after prior notification has been given and approval obtained for the return. To obtain prior approval for the return of the defective items, contact your local Digital Lighting

Systems distributor, representative, or:

Digital Lighting Systems, Inc.

Attn: Customer Service Department

12302 SW 128 Ct. Bay #105

Miami, FL 33186

(305) 969-8442

Upon request, replacement unit(s) will be shipped as soon as available. Unless immediate shipment of replacement merchandise is requested, Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received, inspected, and determined to be defective.

No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written approval from the factory.

Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission.

Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems.

Digital Lighting Systems, Inc.

12302 SW 128 Ct. Bay #105

Miami, FL 33186 www.digitallighting.com

Tel 305-969-8442

Fax 305-969-8675 e-m [email protected]

Printed in U.S.A.11/ 2004

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement