Wahl | 392VX | User manual | HEAT-PROBER HEAT


Add to my manuals
24 Pages

advertisement

Wahl | 392VX | User manual | HEAT-PROBER HEAT | Manualzz

H

EAT

-P

ROBER

®

Hand-Held Thermometers

PW1220 www.palmerwahl.com

170 Years of Continued Innovation

05/08

Table of Contents

Heat Prober ® Table of Contents

Introduction to Heat Probers ® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2, 3

NEW! TM602, TM612, TM630 Pocket Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

RTD M

ETERS

392HP High-Performance Platinum RTD Meter, CAL392HP-HT & -LT Calibrators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

392 Series Platinum RTD Hand-Held Meters, CAL392-HT & -LT Calibrators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Specifications For All Platinum RTD Meters, Options, and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

RTD Meter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Platinum RTD Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9

T

HERMOCOUPLE

M

ETERS

2500/1370 Series Type K Thermocouple Meters, Thermocouple Calibrators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

TM410 Food Service Meters, TM500 Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Specifications For All Thermocouple Meters, Options, and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Thermocouple Meter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Type K Thermocouple Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15

Type K Thermocouple Probe Systems and Extension Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

New Sanitary Probe, Heavy Duty Piercing Probe, Custom Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

D

IPSTICK

T

HERMOMETERS AND

T

HERMISTORS

TC840 Type S and TC850 Type K Series Molten Metal “Dipstick” Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

700M Series Thermistor Meters with Interchangeable Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Why so many Heat-Prober

®

Meters?

Meters are the basic component of a Heat-Prober System. Probes, no matter how well designed and constructed will not compensate if the wrong meter is chosen for the job. Wahl Heat-Probers are offered in three basic measurement types:

Platinum RTD

Platinum Resistance Temperature Detectors (RTD’s) are recognized as the most reliable standard for measuring temperature information. Platinum provides long-term stability, response and repeatability for use as a primary standard. It has a wide useful temperature range and can be used in varying conditions, making it ideal for many applications.

Thermocouple

Thermocouple portable temperature sensors have the advantage over other types due to their fast response, wide temperature range, and ruggedness. The sensors are small in size, versatile and convenient to use. An added advantage of thermocouple use is derived from their wide-spread availability and meter/probe compatibility.

Thermistor

Thermistor sensors offer excellent accuracy and long-term stability, but over a relatively narrow temperature range. Thermistors are generally used to measure moderate temperatures in applications demanding greater accuracy than thermocouples, but less demanding than Platinum RTD Thermometer

Systems.

Each type has advantages and characteristics described in the catalog sections to follow. Basically the differences center on accuracy, temperature range, type of display and price.

TM410 Type K Meter with TP-100 Penetration Probe

2

170 Years of Continued Innovation

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

NEW!

TM602 • TM612 • TM630

Pocket Thermometers

Measurement with Thermocouple, RTD or Thermocouple and RTD

Rugged IP54 Construction for On Site Use

User friendly and robust, the New Wahl TM Series Pocket Thermometers are designed to simplify temperature transmitters and probes maintenance and commissioning. They feature 0.02% Accuracy and measure in Thermocouples and/or

RTD’s. Resolution is programmable for better reading by user with up to 1m Ω or 1µV.

TM602 Thermocouple Thermometer

TM612 RTD Thermometer

NEW!

TM630 Thermocouple and RTD Thermometer

• Well adapted for different process job procedures due to their wide choice of ranges and specific functions such as data recording

• Very low temperature coefficient: 15ppm/°C in thermocouples, 10ppm/°C in resistance

• Optional DATACAL Calibration Management Software

• Accuracy is maintained even in harsh environmental conditions

• Measurement of 14 thermocouples and 12 RTD types

• Data Recording and Onscreen analysis

• High Accuracy: 0.02% of Reading

• Display in °C, °F, mV and Ohm

For a complete specifications and probe selection please visit www.palmerwahl.com

and click: Hand Held Instruments

> RTD Meters and Probes or

Thermocouple Meters & Probes

TM Series

Pocket

Thermometers

WARRANTY

What is a Heat-Prober

®

?

Wahl pocket-sized digital Heat-Probers are complete, high performance portable temperature measurement systems. Wahl originated the systems approach to provide engineers, technicians and research scientists the high confidence required for “routinely critical” temperature measurement.

A Heat-Prober “system” consists of a meter and a sensing probe.

The Heat-Prober meter serves (by means of a microprocessor) to accurately interpret the temperature sensed by the probe, provide digital output and allow measurement options such as peak reading hold or maximum/minimum memory. The meter also contains the power (battery) to allow complete system portability.

Heat-Prober probes are designed to be interchangeable. This allows a meter/probe system to be formed with any number of probes for specific applications used interchangeably with the meter. More probes for additional applications or replacement probes may be purchased, or an additional or replacement meter can be utilized without replacing existing probes.

Accuracy

Because of the Heat-Prober meter’s microprocessor, the probe’s sensor can be linearized to yield maximum accuracy at all points within the measuring range. Probe design is also a large factor in accuracy. The ability to select a standard or custom probe specific to the task and constructed from superior materials, is a key in “system accuracy.”

Portability and Ruggedness

A Heat-Prober’s battery power and rugged compact design make them the perfect choice for service and maintenance technicians who must use their temperature measurement equipment on the move and in a variety of tough environments. Kits with userselected probes are available for many of the meters. Heat-

Probers store away in small spaces without special requirements.

Versatility

Wahl offers Heat-Prober meters utilizing platinum RTD,

Thermocouple and Thermistor technology. Many meters offer range, display and kit options. All meters have a full set of interchangeable probes carefully designed and built to perform specific measurement tasks. This approach allows Heat-Prober users maximum versatility in specifying, purchasing, utilizing and maintaining a temperature measuring system suited to their needs.

Cost Effectiveness

Buy meters and interchangeable probes specifically for your applications and needs. Replacement and additional probes can be purchased as required.

Service

Wahl maintains a complete calibration lab with NIST traceability.

This service allows your Heat-Prober meters, probes or systems to be calibrated at standard or user-specified points. Wahl also offers repair service for meters and probes.

05/08

Type K Thermocouple Probe

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

3

RTD Meters

392HP Series 392 High Performance Platinum

RTD Thermometer System

Exceptional Accuracy and Long-Term Stability in a

Versatile Meter System with Interchangeable Probes

392HPF Meter Range: -290° to 1450°F

392HPC Meter Range: -180° to 788°C

392HPD Dual Scale Meter Range: -290° to 1450°F (-180° to 788°C)

• Meter Accuracy ±0.1°F/C at 32°F (0°C)

• System Accuracy ±0.25% of reading (392HP Meter & 202HP Immersion Probe)

• Complete tracing of the platinum standard DIN 43760 to 0.1°F conformity over the entire temperature range

• Readings updated 2.5 times per second

• Bright 0.33" high-visibility LED display

• Maxi-Temp ® holds peak temperature reading

• Tough, drop tested meter assembly

• Interchangeable, 4-wire snap-in connection HP Series probes

• Automatic compensation for probe calibration of temperature at ice point and alpha

• Noise suppression circuit

A PPLICATIONS

• NIST traceable conforming to ITS-90

Wahl invented the portable Platinum-RTD Thermometer

(Pat. No. 4,050,309) to provide exceptional accuracy and conformity in laboratory and industrial applications. The

392HP Meter/Probe System represents the ultimate in

Heat-Prober System Performance.

Thousands of 392HP Heat-Probers are used by various industries, making critical temperature measurements as well as calibrating sensors and other instruments.

• Petrochemical

• Food

• Photographic

• Aerospace

• Electronics

• Nuclear Power

392HPC Meter

Use the 392HP system to calibrate installed sensors, to make quality assurance tests and to make highly accurate process temperature measurements. An internal feedback loop maintains system calibration during use. And you can order additional HP probes at any time without calibration.

The 392HP features a special noise rejection program for use near high EMF machines.

5-P

OINT

NIST T

RACEABLE

RTD C

ALIBRATORS

See pages 6-7 for complete meter

Assures System Reliability Before Every Measurement specifications, options, accessories, and money saving kits.

See pages 8-9 for Platinum RTD Probe

CAL392HP-HT High Temperature Calibrator for 392HP only,

NIST Certificate included listings.

Calibration Points: -58°F, 32°F, 212°F, 284°F, 752°F

-50°C, 0°C, 100°C, 140°C, 400°C

392HP Probe Connector

WARRANTY

CAL392HP-LT Low Temperature Calibrator for 392HP only

Ice Point to Boil

Calibration Points: 32°F, 68°F, 104°F, 140°F, 212°F

0°C, 20°C, 40°C, 60°C, 100°C

392HP Meter is FM (Factory Mutual) approved for potentially explosive environments.

Class I & II Div. 1, Groups D, F & G.

The performance of our meters is warranted for three years against defects in parts and workmanship.

10786-NIST Certificate of NIST Traceability with Test Data.

To request Custom Calibrators with special calibration points, please contact Customer Service.

Application Example with 392MF

Meter and optional 5-point

Calibrator, CAL392-HT

4

170 Years of Continued Innovation

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

392 Series Platinum

RTD Thermometer Systems

RTD Meters

392 Series

392 Precision Systems Offer Wide Temperature Range and Meter Options

392MF Meter Range -60° to 752°F

392MC Meter Range -51.1° to 400°C

392MD Dual Scale Meter Range -60° to 752°F (-51.1° to 400°C)

• Meter options for display type and power source

• Meter accuracy of ±0.1°F/C ±1 digit at 32°F (0°C)

• System accuracy ± 0.5% of reading ( Meter & 202 Immersion Probe )

• Large LED or LCD display for indoor or outdoor readings

• Interchangeable Platinum RTD probes

• Peak Hold and Auto-Ranging display features.

• Interchangeable probes compensated for calibration at ice point

• NIST traceable conforming to ITS-90

392EXC Meter

Model 392M features a bright .33" high red LED display for normal to low lighting conditions. It operates on a rechargeable NiCad battery pack.

Includes battery recharger and AC line adapter.

Model 392MX features a 0.4" high red LCD for normal to bright lighting conditions and operates on a rechargeable NiCad battery pack. Includes battery recharger and AC line adapter.

Model 392VX features a .4" high red LCD for normal to bright lighting conditions and is powered by a 9volt alkaline battery for 50 hours continuous use making it an excellent choice for field tests.

-S Models are FM approved for additional groups, see specifications on page 6.

Use F, C, or D Model No. suffix to designate

Fahrenheit, Celsius, or Dual Range °F/°C Switchable.

See pages 6-7 for complete meter specifications, options, accessories, and money saving kits.

See pages 8-9 for Platinum RTD Probe listings.

A precision, microprocessor driven meter is the heart of a complete, portable and rugged Heat-Prober temperature measurement system.

Using 392 Meters, engineers in maintenance, quality assurance, energy conservation and process control can now have laboratory accuracy anywhere in the plant, laboratory, or field.

The 392 system gives you outstanding accuracy with a choice of interchangeable probes for measuring surfaces, liquids, semi-solids and gases. Interchangeable 3-wire, snap-in connection Platinum-RTD probes are shown on pages 8 and 9. In addition, 392 Meter/Probe

Systems are ideal for use as an in-house calibration standard for less accurate thermometers and to calibrate installed thermowells.

For complete portability and ease of use, Wahl Heat-Prober Meters are battery powered. The 392 Series are supplied with rechargeable batteries that allow 8 hours continuous operation. The supplied recharger allows these meters to be used as a continuously operating bench unit. For field backup, a spare rechargeable battery pack (page 6) may be purchased.

5-P

OINT

NIST T

RACEABLE

RTD C

ALIBRATORS

All 392 Series Meters assure laboratory accuracy in the field when used in conjunction with the NIST traceable

Calibrator CAL392.

Assures System Reliability Before Every

Measurement

CAL392-HT High Temperature Calibrator, NIST

Certificate included

Calibration Points:

-58°F, 32°F, 212°F, 284°F, 752°F

-50°C, 0°C, 100°C, 140°C, 400°C

CAL392-LT Low Temperature Calibrator

Calibration Points:

32°F, 68°F, 104°F, 140°F, 212°F

0°C, 20°C, 40°C, 60°C, 100°C

Platinum RTD Meter 392MF shown with 5-point calibrator CAL392-HT

WARRANTY

10786-NIST Certificate of NIST Traceability with

Test Data.

05/08

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

5

RTD Meters

Specifications

& Accessories

RTD Meter Specifications

See our New TM612 RTD Thermometer, and

TM630 Thermocouple and RTD Thermometer featured on page 3.

392 S

ERIES

RTD M

ETER

S

PECIFICATIONS

Model

Range

Digital Display

392HP

-290 ° to 1450°F

-180 ° to 788°C

Bright 0.33"

LED

392M

392MX

-60 ° to 752°F

-51 ° to 400°C

392M/392M-S

Bright 0.33" high LED

392M-S

392MX-S

-60

-51

392VX

° to 752°F

° to 400°C

392MX/392MX-S

Red, 0.4" high LCD

0.1° below 375°F (190°C). Auto Ranges to 1˚ above 375°F (190°C).

Red, 0.4" high LCD

Resolution

Meter Accuracy at 77°F

System Accuracy

(Meter with 202 immersion probe)

±0.1°F ±1 digit at ice point,

±0.25% reading thereafter

Repeatability

Peak Hold

±0.1°F/C ±1 digit at 32°F (0°C)

±0.3°F at ice point,

±0.5% reading thereafter

±0.2°F

Microcomputer calculated, switch to “P” to activate

0 ° to 130°F (-18 ° to +55°C) Ambient Operating Range

Temperature Coefficient 0.01 deg/deg over ambient range

FM (Factory Mutual)

Approved*

Power

Battery Life

Class I & II,

Div. 1, Groups:

D, F, & G

11681-1

6.25 V

NiCad Battery

4.5 hours. per charge

Class I & II,

Div. 1, Groups:

D, F, & G

Class I & II,

Div. 1, Groups:

C, D, E, F, & G

11681-1

6.25 V

NiCad Battery

11681-2

6.25 V

NiCad Battery

392M/392M-S

10 hours per charge

392MX/392MX-S

50 hours per charge

Yes

Not

Available

9V Alkaline battery

(NEDA 1604A)

50 hours.

per charge

Low Battery Indicator

Noise Rejection

Greater than 40 dB at 60 Hz increasing at 20 dB per decade. Spurious noise attenuated by internal 16 Hz filter. 392HP includes special noise rejection program for use in presence of rampant EMF such as spark ignition engines.

Size

Weight 12 oz. (340grams)

3" W x 6" L x 1.5" D (7.5 cm x 15 cm x 3.75cm)

12 oz. (340grams) 7 oz. (198grams)

* FM Approval Groups: C (Ethylene Gas), D (Methane, Propane), E (Metal Dust), F (Coal Dust), and G (Grain Dust)

All 392 Models Available in °F, °C, or Dual Scale, add “F”, “C” or “D” to Model Number. Dual Scale not available on -S Models.

392 S

ERIES

M

ETER

A

CCESSORIES

DA-4 Silicone Paste

DA-6 Belt-Clip Meter Case with Hand Strap

MA-150 Battery Recharger, 120V AC 50/60Hz

MA-150E Battery Recharger, 220V AC 50/60Hz, European

DA-10 Nylon Safety Wrist Strap

DA-60 Shock-Proof Attache-Style Instrument Case

11681-1 Spare NiCad Battery Pack

11681-2 Spare NiCad Pack for -S Models

392NIST

12232 Standard 9V Alkaline Battery

M ETER O PTIONS

Certificate with 3 Standard Calibration

Points between 32°F (0°C) & 500°F (250°C)

Meter calibration includes one probe.

392NIST-1

Certificate with 3 User-specified Calibration

Points between -40°F (-40°C) & 600°F (315°C)

Meter calibration includes one probe.

WARRANTY

6

170 Years of Continued Innovation

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

RTD Meter/Probe Kits

Compact, ready-to-use Heat-Prober Kits provide everything you need for precise temperature measurements anytime, anywhere.

RTD Meters

& Probe Kits

Save 15%

Kit prices are 15% less than total prices of component models purchased individually.

PLUS Save 15% on any additional probes purchased with kits.

K392EVX Heat-Prober

Precision Temperature

Measurement/Calibration Kit

Meter Options

392NIST Certificate of NIST traceability with test data at 3 standard calibration points between 32°F (0°C) and 500°F (250°C).

Meter calibration includes one probe.

392NIST-1 Certificate of NIST traceability with test data at 3 user-specified calibration points between -40°F (-40°C) and 600°F (315°C).

Meter calibration includes one probe.

Extra points available.

Heat-Prober High Performance Kit

K392HP-1 and K392HP-2

Choose the high performance kit to:

• Calibrate installed sensors

• Calibrate portable instruments

• Measure temperatures with accuracy to ±0.25% of reading

K392HP-1 includes:

392HP Thermometer,

Specify F (°F), C (°C), or D (°F/°C Dual Scale)

202HP Sensitive Immersion Probe

CAL392HP-HT Calibrator

DA-60 Shock-proof attache-style Instrument Case

MA150 Battery Charger, specify 120V AC or 220V AC

K392HP-2 includes:

392HP Thermometer,

Specify F (°F), C (°C), or D (°F/°C Dual Scale)

145HP Surface Probe

202HP Sensitive Immersion Probe

CAL392HP-HT Calibrator

DA-4 Silicone Paste

DA-60 Shock-proof attache-style Instrument Case

MA150 Battery Charger, specify 120V AC or 220V AC

Heat-Prober Precision RTD Kit

K392VX

Choose the versatile high accuracy kit to:

• Measure most surfaces, liquids and gases with excellent repeatability

• Calibrate installed sensors

• Full line of interchangeable probes available without meter recalibration

K392VX includes:

392VX Thermometer,

Specify F (°F), C (°C), or D (°F/°C Dual Scale)

145 Spring Articulated Surface Probe

202 High Sensitivity Immersion Probe

CAL392-HT Calibrator

DA-4 Silicone Paste

DA-60 Shock-proof attache-style Instrument Case

You may substitute Heat-Prober Thermometer 392M, 392MX,

392M-S, or 392MX-S.

Specify 120V AC or 220 V AC for recharger.

You may also add or substitute any Wahl Platinum-RTD probe listed on pages 8 and 9. Contact Customer Service for prices and for additional portable Platinum RTD probes. Remember that additional probes purchased with a kit are priced at 15% off.

Custom Probes for Your Applications

Contact Wahl for custom-made probes to your specifications, or let us help you design the right probe for your application.

05/08

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

7

RTD Meters

392 Series

Platinum RTD Probes

392 Series Platinum

RTD Probes

Platinum resistance temperature detectors (RTD’s) are recognized worldwide by metrology laboratories as the most reliable standard for measuring and comparing temperature information. Platinum provides long-term stability and repeatability for use as a primary standard. It has a wide useful temperature range which makes it ideal for laboratory and industrial applications.

Our accurate, stable platinum sensors are housed in thin wall stainless steel shanks with low mass tips that don’t compete with the measured object. That’s why Wahl probes have fast response, and provide an accuracy of ±0.2°F at ice point, ±0.5% of reading thereafter.

Every probe is engineered to do a specific job in measuring surfaces, liquids, semi-solids or gasses. Each probe has a high quality, heatresistant Delrin ® handle, a coiled 5-foot cord and a snap-in connector that mates it solidly to our thermometer (exceptions noted in descriptions below).

Every probe is calibrated at two or three temperature points on NIST traceable secondary standards and tagged “Wahl Test Certified” with calibration data. You can order a NIST certificate with test data for meters and probes. See page 6.

For 392HP Probes, simply add “HP” after Model Number

112 Fine-Tip Penetration Probe for foods and other soft substances.

.084" diameter, 1" long tip at the end of a 2-3/4" overall length shank. 450°F temperature limit with 3 second response (2) .

114 Heavy-Duty Piercing Probe for plastic melts, rubber, asphalt, frozen foods, or other semi-solids. Adjustable penetration depth limiter. 900°F temperature limit with 3.7 second response (2) .

4-1/2" shank length is 1/8" diameter with penetration tip.

121 Spring Articulated Straight Surface Probe for molds, dies, platens, electronics, machine housings and all other surfaces.

Spring tip allows conformity and maximum contact to measured surface. 900°F temperature limit; 2-second response (1) . 4-1/4" shank, .25" diameter, straight tip design. Also with -12" and -18" shank lengths.

123U Right Angle Fast Surface Probe sealed sensor design with low profile 90° bend tip for reaching into die and mold cavities, electronic chassis, or other restricted areas. 900°F temperature limit, 3-second response (1) . 4" shank, .250" diameter tip

124 Rigid Shank Fast Surface Probe. Sealed sensor design for rugged applications. 4" shank length, straight tip. 900°F temperature limit with 3 second response (1) .

145 45° Spring Articulated Surface Probe, for molds, dies, platens, electronics, and all other surfaces. Spring tip allows conformity and maximum contact. 4" shank and 45° tip angle.

155 Bolt-on Surface Probe for permanent installation. Used to monitor engine or reactor surface temperatures. Copper sheathed sensor with .218" diameter bolt hole. 10' stainless steel covered cable and connector. 930°F; 2 second response (2) .

No handle.

172 Self-Adhesive Surface Probe Polymer-encased sensor in a 1.25" x 1", pressure-sensitive adhesive patch. 10' Teflon coated cable

(no handle). Used for monitoring environmental tests, curing cycles, and oven processing. 350°F temperature limit with 1 second response (2) .

201 General Purpose Immersion Probe for liquids, foods, candy, granular materials, and semi-solids. 5.75" long X .125" diameter shank. For measurements to 600°F with 1.7 second response (2) .

202 Sensitive Immersion Probe with low mass .084" diameter. 5" long shank. Super fast response time of 1.4 seconds (2) for use in all liquids and semi-solids. Temperature limit of 900°F.

Response time legend (to 63%): (1) Measured on flat surface at 400°F;

(2) Measured in boiling water; (3) Measured in air at 10 fps

Look for the “Wahl Tested

Certified” calibration tag on every probe.

Custom Probes for Your Applications

Contact Wahl for custom-made probes to your specifications, or let us help you design the right probe for your application.

121 Spring Tip

Surface Probe

205

Heavy-duty

Immersion Probe

205SH

Heavy-Duty

Shielded

Immersion

Probe

204CT

Paddle Probe

305

Miniature

Air/Gas

Probe

112

Fine-Tip

Penetration

Probe

172

Self-Adhesive

Surface

Probe

155

Bolt-on

Surface

Probe

123U Right Angle

Surface Probe

8

170 Years of Continued Innovation

Probe listing continued on page 9

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

RTD Meters

392 Series

Platinum RTD Probes

212

12" Fully

Immersible

Probe with no handle

202

Sensitive

Immersion

Probe

124

Rigid Shank

Fast Surface

Probe

114

Heavy-Duty

Piercing

Probe

302

Air/Gas

Probe

145

45˚ Spring Articulated

Surface Probe

Wahl Exclusive Surface Probes

For surface probes where it is necessary to bring the greatest amount of surface heat in direct contact with the sensor, a unique design developed for the U.S. Space Program is employed. The coil is bonded to a platinum base plate of low thermal resistance which contacts the measured surface. The platinum base, in turn, is bonded directly to a thin stainless steel, bell-shaped housing of low mass. Heat loss is impeded by high thermal resistance elements: stainless steel housing, shank and coil spring.

The coil spring in Wahl 121 and 145 surface probes provides automatic articulation of the tip for conformity and uniform contact with the surface being measured.

This is especially useful in blind recesses where contact measurements are made by “feel” instead of sight.

Wahl Platinum-RTD Probes Are

Interchangeable Without

Recalibration

Only Wahl offers an interchangeable probe system that assures consistent accuracy and

±0.2°F repeatability without meter recalibration. Our most popular probes are shown on these pages. Contact Wahl for more of our precision Platinum-RTD probes.

Custom Probes for Your Applications

Contact Wahl for custom-made probes to your specifications, or let us help you design the right probe for your application.

For 392HP Probes, simply add “HP” after Model Number

203 Teflon-Coated Immersion Probe for use where corrosive solutions and possible metallic contamination are a concern.

5" shank, .084" diameter 450°F limit, 2 second response (2) .

204 12" Long-Reach Immersion Probe with 12" shank (.125" diameter.) for baths, vats, kettles and other deep vessels.

900°F limit with 2 second response (2) .

204CT Paddle Probe for crystallization and fluid temperatures while agitating liquids. 3/4" wide paddle tip; .125" diameter shank is

10" long to the paddle tip. 900°F limit with 2 second response (2) .

205 Heavy-Duty Immersion Probe for solder baths, liquids, granular materials, and gas. 8" shank. Also with -12", -18", and -24" shank lengths. All have .125" diameter tip. 900°F limit; 3 second response (2) . Consult factory for Teflon coating option.

205SH Heavy-Duty Shielded Immersion Probe. Shield protects the tip from the shock of hitting vat or container walls. 24" length shank has .125" diameter. with 3/8" diameter. shield.

Temperature limit of 900°F; 7.25 second response (2) .

212 Fully Immersible Probe with no handle for plating baths, dipping solutions, brewing vats, storage vats, tanks, rivers and streams. Temperature limit of 450°F; 2 second response (2) . 0.125" diameter. by 12" length shank with 10'

Teflon cable with connector.

302 Air/Gas Probe with perforated sensor shield to induce good velocity and prevent radiation errors, used in industrial application such as ovens, stacks and ducts. 850°F temperature limit, 6 second response (3) . 6-5/8" shank, 3/8" diameter. 2" long shield.

305 Miniature Air/Gas Probe highly sensitive, low mass sensor is shielded by thin, small diameter (.120") perforated steel tube for fast response HVAC applications. 450°F limit, 4 second response (3) .

Response time legend (to 63%):

(1) Measured on flat surface at 400°F

(2) Measured in boiling water;

(3) Measured in air at 10 fps

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

05/08

9

Thermocouple Meters

2500/1370 Series 2500/1370 Series Type K

Thermocouple Meters

2500 Meter Range -100° to 2500°F

1370 Meter Range -70° to 1370°C

• Meter options for °F or °C range, display type and power

• Meter accuracy is ±0.2% of reading ±1 digit

• Maxi-Temp ® automatically holds peak reading

• Accepts all type K probes with ANSI mini-connectors

• Microprocessor circuitry for thermocouple linearization

Heat-Prober ® Thermocouple Thermometers and Probes are rugged and reliable instruments made for process and maintenance temperature measurements.

The pocket-sized microprocessor-based Heat-Prober Type K thermometer updates readings three times per second with an accuracy of ±0.2% of reading ±1 digit in 1°F or °C resolution.

The precision cold junction is compensated with a unique, permanently calibrated circuit.

The Wahl Maxi-Temp peak hold switch, available on all models, permits the Heat-Prober to hold and display the highest temperature reached. This function is ideal where the operator must concentrate on the probe when making the measurement and where an instantaneous transient peak is to be recorded.

Maxi-Temp meters also can be switched to normal operation.

Advanced electronics are housed in ABS plastic, thoroughly tested for environmental integrity and subjected to 4-foot drop tests, battery life and running life tests. All units are calibrated with simulated EMF inputs and powered during a hightemperature burn-in cycle.

2500MX Type K Thermocouple Heat-Prober

NIST T

RACEABLE

T

HERMOCOUPLE

C

ALIBRATORS

This thermocouple meter accessory allows calibration over the meter’s full range.

Model 2500M (-100° to 2500°F) features a bright .33" high red

LED display for normal to low lighting conditions. It operates on a rechargeable 6.25V NiCad battery pack. Includes battery recharger/AC line adapter.

Model 1370M as above with -70° to 1370°C range.

Model TCMR-K °F/°C switchable.

Useful for quick field diagnostics, it assures meter accuracy whenever a measurement is in question.

Accuracy is ±0.3°F/°C or

0.2% of reading, whichever is greater.

Model 2500MX (-100° to 2500°F) features a .5" high red LCD display for normal to bright lighting conditions. It operates on a rechargeable 6.25V NiCad battery pack. Includes battery recharger/AC line adapter.

Model 1370MX as above with -70° to 1370°C range.

Model TCMR-KX °F/°C switchable.

TA-70AFK Precision Calibrator in use with 2500MX Thermocouple Meter

NIST Certification included with Calibrator

User sends the calibrator

only back to the factory for NIST Certification.

One Calibrator maintains

NIST traceability for all in-house meters.

Model 2500MVX (-100° to 2500°F) features a .5" high red LCD display for normal to bright lighting conditions and is powered by an easily replaceable single standard 9V battery.

Model 1370MVX as above with -70° to 1370°C range.

Model TCMR-KVX °F/°C switchable.

See Meter specifications on page 12.

See page 12-13 for 2500/1370 Series meter, probe, and accessory money-saving kits.

WARRANTY

See pages 14-17 for interchangeable thermocouple probes.

T

HERMOCOUPLE

C

ALIBRATOR

M

ODELS

Model Type

TA30AFK K

TA50AFK K

TA70AFK K

TA70ACK K

TA70AFT T

Calibration Points

40°F - 140°F - 170°F

100°F - 155°F - 200°F - 250°F - 300°F

130°F - 650°F - 1300°F - 1900°F

70°C - 400°C - 800°C - 1200°C

32°F - 80°F - 150°F - 250°F

10

170 Years of Continued Innovation

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

TP-200

TP-102

TM410 Thermocouple Food

Service Thermometer

TP-101

TP-100

Thermocouple Meters

TM410

TM500

The Wahl TM410 Type K Thermocouple Digital Heat Prober ® Thermometer is economical and compact. It provides the highest accuracy at the lowest price of any Thermocouple Instrument on the market today.

• Accuracy of ±1.0°F (±0.5°C) in an operating range of 32° to 200°F (0° to 93°C)

• Meets and exceeds FDA Requirements (Food Code requires ± 2°F)

• Optional probes plug into the top of TM410 for easy single-handed use

• Optional TCL329K Extension Handle for extended reach

• Built in pocket/belt clip on back of unit

• Reduced dirt-harboring crevices for easy cleaning

• °F and °C Switchable

TM410 with TCL329K Extension Handle allows use of interchangeable probes with one handle and cord set. See page 15 for probe descriptions.

Wahl TP Probes (shown left with TM410, described on page 15) are specially manufactured with food service in mind to give fast and accurate results. They can be inserted into the TM410 for single handed operation and are durable enough to withstand the rigors of a busy kitchen. Probes can be safely passed through the dishwasher for ease of cleaning. Accuracy is maintained regardless of which probe is attached, assuring greater certainty of safe food temperature, and tighter control over the quality of the finished product.

TM410 shown in use with

NIST Certified TA50AFK Calibrator, page 10.

TM500 Thermocouple Meter

The Wahl TM500 Heat Prober Meter offers value with exceptional features. The

TM500 has advanced microprocessor functions, dual display and dual probe capability for more advanced testing in critical process and laboratory applications.

TM500 Type J Range of -328°F to 1922°F (-200°C to 1050°C).

TM500 Type K Range of -328°F to 2498°F (-200°C to 1370°C).

• Large LCD and Dual probe input accepts one or two Type J or Type K

Thermocouple probe(s) with standard ANSI mini-connectors.

• Selectable temperature scale, Fahrenheit or Celsius readings.

• Main LCD displays the temperature reading from either selected probe or the temperature difference between the two.

• Third LCD displays time or timing duration (hours, minutes, seconds) of MAX/MIN or AVERAGE temperature events.

ONE YEAR

1

Type K Range

Type J Range • “Recording” mode allows data storage for MAX, MIN, and

AVERAGE temperatures reached over a time period.

• “Set” mode allows entry of reference and alarm points.

• Supplied with water and shock resistant rubber boot, built-in easel stand, 9V battery, and two Type K test probes.

See Specifications for both Meters above on page 12.

See page 13 for Thermocouple Meter, probe, and accessory money-saving kits.

See pages 14-17 for interchangeable thermocouple probes.

TM500 shown with TC869

45°Spring Articulated

Surface Probe

TM500

C

ALIBRATOR

-328° to 2498°F and -200° to 1370°C

-328° to 1922°F and -200° to 1050°C

Resolution

Meter Accuracy

0.1˚, ˚F or ˚C

±0.05% reading ±0.6°F (0.3°C)

@ -58°/2498°F (-50° to 1370°C)

±0.05% reading ±1.4°F (0.7°C)

@ -58°/328°F (-50 to 200°C)

One standard 9V, NEDA 1604 or equiv.

Power

Display 5 Digit LCD

Meter Size 7-5/8" x 3-5/8" x 2-1/8" (190 x 92 x 54mm)

05/08

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

11

Thermocouple Meter

Specifications

& Accessories

Thermocouple Meter Specifications

See our New TM602 Thermocouple Thermometer and

TM630 Thermocouple and RTD Thermometer featured on page 3

Thermocouple Meter Specifications

Model 2500M 2500MX 2500MVX 1370M 1370MX 1370MVX

Range

Digital Display LED

F/C Switch

Resolution

Meter Accuracy

-100°/2500°F

LCD

Optional

±0.2%

±1 digit

LCD LED

-70°/1370°C

LCD

Optional

±0.2%

±1 digit

LCD

Thermocouple Type

Peak Hold

Ambient Operating

Range

Power

-20°/120°F

-29°/49°C

6.25V NiCad

Recharge Pk

K

Yes

Yes

0°/120°F

-18°/49°C

9V

-20°/120°F

-29°/49°C

6.25V NiCad

Recharge Pk

K

Yes

Yes

0°/120°F

-18°/49°C

9V

No AC Power No

Battery Life 8 hours 50 hours 50 hours 8 hours 50 hours 50 hours

Low Battery Ind Yes Yes

TM410

-40°/1999°F

-40°/1092°C

LCD

Yes

1.0° or 0.1°

±1.0°F @ 32°/200°F

(±0.5°C @ 0°/93°C)

0.3% reading, ±2°F

@ -40°/32°F (-40°/0°C)

0.3% reading, ±2°F

@ 200°/1999°F

±0.4°C @ 93°/1092°C

K

No

32°/122°F

0°/50°C

Three 1.5V AAA

No

140 hours

Yes

TM500

-328°/2498°F

-200°/1370°C

Dual LCD

Yes

0.1°

±0.05% reading

±0.6°F (0.3°C)

@ -58°/2498°F (-50°/1370°C)

±0.05% reading

±1.4°F (0.7°C)

@ -58°/-328°F (-50/-200°C)

J, K

Yes

32°/122°F

0°/50°C

9V

No

100 hours

Yes

Recharger

Included

7.5V @ 100 mA

110 or 220 V AC

Size

Weight

N/A

6" x 3" x 1"

10.5 oz. (298 grams)

7.5V @ 100 mA

110 or 220 V AC

N/A

6" x 3" x 1"

10.5 oz. (298 grams)

N/A

6" x 2" x 3/4"

3.6 oz. (102 grams)

N/A

7.5" x 4" x 2"

15.5 oz. (439 grams)

T

HERMOCOUPLE

M

ETER

A

CCESSORIES

DA-4 Silicone Paste

DA-6 Belt-Clip Meter Case with Hand Strap

DA-10 Nylon Safety Wrist Strap

MA-150 Battery Recharger, 110V AC 50/60Hz

MA-150E Battery Recharger, 220V AC 50/60Hz, European connector

TA-60 Shock-Proof attache-style Instrument Case

11681-1 Spare NiCad Battery Pack

12232 Standard 9V Alkaline Battery

12234-02 3V, Lithium, coin Cell Battery for TA30 and TA50

12235 7.5V, Alkaline, Multi-Cell Battery for TA50 and TA70

NIST-12

NIST-12-1

M ETER O PTIONS

Certificate with 3 Standard Calibration Points between 32°F (0°C)

& 500°F (250°C). Meter calibration includes one probe.

Certificate with 3 User-specified Calibration Points between -40°F

(-40°C) & 600°F (315°C). Meter calibration includes one probe.

Sample Meter Kit sold on pages 7 and 13. Kit includes

Meter, Carrying Case, Calibrator, Wrist Strap, Recharger and Probe.

12

170 Years of Continued Innovation

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

Type K Meter/Probe Kits

Thermocouple Meter

Kits

Save 15%

Kit prices are 15% less than total prices of component models purchased individually.

PLUS Save 15% on any additional probes purchased with kits.

K2500VX °F Extension Handle Kit:

For your toughest factory applications.

• 2500MVX Type K thermometer

• TC829-12 12" Extension Handle

• RTC822 Z-Tip Fast Response Surface Probe

• RTC828 Replaceable Immersion Probe

• TA70AF Calibrator

• DA-4 Silicone Paste

• TA-60 Shock proof attache-style Instrument Case

For °C meter, specify K1370VX

For °F/°C switchable meter, specify KTCMR-KVX

K2501VX ˚F Extension Handle Kit:

For surface measurements.

• 2500MVX Type K thermometer;

• TC829-12 12" Extension Handle;

• RTC822 Z-tip Fast Response Surface Probe

• TA-60 Shock proof attache-style Instrument Case

For °C meter, specify K1371VX

For °F/°C switchable meter, specify KTCMR-KVX

Heat-Prober Kits can be custom-ordered to include meters, probes, extension handle systems and accessories for your temperature measurement needs.

Kit prices are 15% less than total prices of component models purchased individually. PLUS Save 15% on any additional probes purchased with kits.

You may substitute Heat-Prober Thermometers 2500M and 2500MX in any kit. Specify 120V AC or 220V AC for recharger.

K2502VX ˚F Meter/Probe Kit:

For general purpose use.

• 2500MVX Type K thermometer

• TC809 H Heavy-Duty Surface Probe, 45˚ tip

• TC801 Immersion Probe

• TA70AF Calibrator

• DA-4 Silicone Paste

• TA-60 Shock proof attache-style Instrument Case

For °C meter, specify K1372VX

For °F/°C switchable meter, specify KTCMR-KVX

Custom Probes for Your Applications

Contact Wahl for custom-made probes to your specifications, or let us help you design the right probe for your application.

Custom TM410 Food Service

Kit shown with optional accessories: TA50AFK

Calibrator, TCL329K Extension

Handle, Type K Probes, Temp-

Plate ® Temperature Labels and cleansing wipes (not included).

Save 15% when purchased as a Kit!

TM410 Probe Kit:

Customize Your TM410 - Food

Service Kit to ensure your

HACCP program maintains the most stringent standards, at the lowest cost.

Purchase a TM410 Prober and choose the optional accessories that best suit your needs:

TA50AFK - NIST Certified

Calibrator

TCL329K - Extension Handle

12423 - Hard Foam Lined

Carrying Case

Type K Probes (See pg 14 & 15 for part number and description, Economy TP Probes are best suited for Food Service programs)

Temp-Plate ® Temperature Labels

#414-160F-071C (box of 20)(recommended for testing internal water temperature of dishwasher's)

05/08

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

13

Thermocouple Meters

Type K Probes Type K Thermocouple Probes

Probes for High Performance

The quality of temperature measurement depends principally on the probe design as it relates to the object being measured. That’s why each of Wahl’s interchangeable thermocouple Type K probes is scientifically engineered to do a specific job.

Wahl thermocouple probes are designed for the fastest response possible depending upon use.

Each starts with the thermocouple junction, precision welded for virtually instant response. Then a stainless steel sheath is created with a thin wall for fast measurements or a thicker wall for heavy duty applications. Surface probe tips are Wahl-engineered to provide optimum contact with the least thermal load.

Thin wall 300 series stainless steel sheath results in fast probe response.

Rugged Delrin ® handle withstands high temperatures.

Portable probes have (except as noted) rugged Delrin ® handles, ANSI mini-connectors and 5-foot flexible compensated cables.

These probes are compatible and interchangeable for use with Wahl Heat-Prober Meters 2500/1370 series (page 10), TM410, and TM500 (page 11).

Calibration Traceable to NIST

All thermocouple probes are individually calibrated at two temperature points to the same NISTtraceable secondary standards and tagged with calibration data. Probes are calibrated with your purchased meter or with a factory maintained standard, so you get guaranteed precise temperature measurements in the harshest environments.

Flexible compensated cable takes abuse.

Type K ANSI miniconnector plugs solidly into thermocouple meters.

Look for the “Wahl Tested

Certified” calibration tag on every probe.

TC801 Immersion Probe S.S. sheath with grounded junction and 1/8" diameter, 10" shank for fluids, corrosive mixtures, solder baths and viscous materials to 1600˚F. 6 sec. response (2) . For 24" shank, order

TC801-24.

TC803 Electronics Tip Probe for electronic and biological applications. Low mass, 0.032" diameter fine-point sensing tip measures small components with minimal disturbance. Limit of

900°F., 5 sec response (1) .

TC805 Air/Gas Probe with perforated radiation shield over bare head thermocouple junction for fast response and good accuracy in high temperature radiation backgrounds. 8" shank, to 1200°F, 45 sec.

response in circulation oven. Available as TC805-24 with 24" shank.

TC809 Heavy-Duty Surface Probe System. Low mass provides accurate and fast response for surface temperature measurement of ingots, furnaces, kilns, molds and platens to 1200°F limit with 3 second response (1) . Utilizes snap-in, (replaceable and Surface Probe interchangeable) probe tips with miniature Z-tip, spring-loaded thermocouples protected by ceramic housing. Braided stainless steel

4' extension cable, extra heavy duty handle with 5" shank (optional 12" shank). Order with desired tip below.

TC809H Heavy Duty Surface Probe, 45° tip; TC809H-12 for 12" shank.

TC809R Heavy Duty Surface Probe, 90° tip; TC809R-12 for 12" shank.

TC809S Heavy Duty Surface Probe, straight tip; TC809S-1212" shank.

TC809 Tips Only: TC821H 45° tip; TC821R 90° tip; TC821S straight tip.

Response time legend (to 99% of 212˚F): (1) clean hot plate surface, (2) immersion in boiling water (3) immersion in liquid solder bath

Custom Probes for Your Applications

Contact Wahl for custom-made probes to your specifications, or let us help you design the right probe for your application.

TC813

Bolt-on

Surface

Probe

TC801

Immersion

Probe

TC803

Electronics

Surface

Probe

TC805

Air/Gas

Probe

TC869

45° Spring

Articulated

Surface Probe

TC809H

Heavy Duty Surface Probe

System with 45° tip

Replaceable Heavy Duty

Surface Probe Tips only:

TC821R 90°Tip

TC821S Straight Tip

TC821H 45° Tip

Probe listing continued on page 15

14

170 Years of Continued Innovation

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

Revised 6/10.08

Type K Thermocouple Probes

Thermocouple Meters

Type K Probes

TC812K Magnetic Surface Probe with 3 lb. pull magnet attaches easily to ferrous surfaces. Measurements to 450°F, 30 sec response (1) ,4-ft over-braid cable (no handle). Spring loaded follower holds thermocouple junction firmly against surface.

TC813 Bolt-On Surface Probe for continuous monitoring, withstands hazardous environments to 1600°F. Rigid 5/8" diameter, 1/8" thick

S.S. washer, high-temperature 4 ft. overbraid cable (no handle). 20 sec. response (1)

TC814 Hypodermic Probe for minimal disruption when inserted into semi-solids up to 1000°F. 2-1/2" long stainless steel shank is 0.05" diameter. Sharpened tip yields extremely fast readings (0.5 second (2) response).

TC817 Heavy-Duty Piercing Probe for plastic melts, rubber, asphalt, frozen foods, or other semi-solids. Adjustable penetration depth limiter. 1000°F temperature limit with 4 second response (2) . 4-1/2" shank is 3/16" diameter with penetration tip which tapers to 0.1".

TC861 Pencil-Type Electronic Tip Probe with 7/16" hardened shank,

0.032" diameter. For electronic component testing up to 600°F.

Response of 2 seconds (1) .

Response time legend (to 99% of 212˚F): (1) clean hot plate surface, (2) immersion in boiling water (3) immersion in liquid solder bath

TC867 Soldering Iron Tester Probe unique patented TC Sensor.

Instant checking of iron for critical operations. Probe contains solder at junction tip. Soldering iron melts solder to establish true temperature as required by MIL specifications.

TC869 45° Spring Articulated Surface Probe provides certain surface contact for platens, hot plates, molds, etc. to 1000°F. 1/8" diameter x 8" shank., 250" tip diameter. 4 sec.response

(1)

TC871 Threaded Plug-Type Probe for shell cavities and machinery walls to 850°F, 6 sec response (1) . 188˚ cone with backup, 7/16" hex nut threaded 3/8" - 24NF, 4 ft overbraided cable (no handle).

TC873 Right Angle Surface Probe with long reach 6" handle, flexible bands for rolls, curved surfaces, platens, molds. Ceramic/metal head to

572˚F limit, 2 sec response (1) , 90° head, 1/2" high, 1/2" tip diameter. Fits in 2-1/2" clearance.

RB873 Spare bands for TC873, pkg/2.

TC873

Right Angle

Surface

Probe

TC814

Hypodermic

Probe

TC861

Pencil-Type

Electronic

Probe

TC805F

HVAC Test

Probe

TC812K

Magnetic

Surface

Probe

TC871

Threaded

Plug-Type

Probe

TC817

Piercing

Probe

E

CONOMY

T

YPE

K

AND

J T

HERMOCOUPLE

P

ROBES

Economy Type K Thermocouple Probes

For routine maintenance and testing applications. TCL329K Extension Handle allows use of interchangeable, “direct to meter” probes with one handle and cord set. This economical and compact Type K probe system is usable with any Wahl

Thermocouple Meter, but works especially well with TM-410, page 11.

Direct Connect to Meter Probes

TP-300

Model No.

TP-100

TP-101

TP-102

TP-200

TP-300

Description

Needle-Tip Penetration Probe, 4" shank, direct connect to meter

Fine-Tip Penetration Probe, 4" shank, direct connect to meter

Sharp-Tip Penetration Probe, 6" shank, direct connect to meter

General-Purpose Immersion Probe, 8" shank, direct connect to meter

Alligator Clip-on Oven/Air Probe, 4' length, high temperature insulated connector cable

TCL301J/K* General Purpose Probe with Delrin handle, 8" shank with .125" diameter

TCL309J/K* Handle and Probe Set. TCL329K handle sold with TCL383K immersion probe

TCL329J/K* Handy Extension Handle for use with direct connect probes. 4" Handle accepts all

ANSI mini-connector type J or K probes. 5' coiled lead connects to meter.

TCL363J/K* Unmounted 3' Bare Thermocouple, exposed junction

TCL383J/K* Immersion Probe, 8" shank with .125" diameter, direct connect to meter

* Specify J or K at end of Model Number. For additional Type J Thermocouple Sensors Probes, consult Customer Service for specifications, availability, and pricing.

TP-200

TP-100

TP-101

TP-102

TCL329 Extension Handle

05/08

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

15

Thermocouple Meter

Probe Systems and

Extension Handle

Type K Thermocouple Probe

Systems and Extension Handle

TC829 Extension Handles are designed for rugged, long-reach applications. The TC829

Handle/Probe System is compatible with any Wahl Thermocouple Heat-Prober Meter. Screw on any of the replaceable RTC Series probes and go to work with confidence. The TC829 has an articulated head and a three-foot stainless steel armored cable with reinforced ANSI miniconnector. The chrome-plated handle is contoured to assure a solid grip. Order by length.

Part No.

TC829-12

TC829-24

TC829-36

TC829-48

Length

12"

24"

36"

48"

RTC823

16

RTC822L

TC829 Systems have a fully articulated head for adjustment to any measurement angle required.

RTC822 Z-Tip Fast Response Surface Probe for molds, platens, dies, bearings, glass or any other clean surface to 1000°F 3 sec.

response (1) . 1/2" diameter tip x 1" length.

RTC822L Heavy Duty Z-Tip Fast Response Surface Probe has an upper temperature limit of 1500°F, 5 sec. response (1) . 1/2" diameter tip x 2 1/4" length.

RTC823 Spring-Loaded Z-Tip Surface Probe has patented protective collar. Mechanical stop provides 0.020" clearance for ceramic tip to increase life of probe. Upper temperature limit:

1000°F. 3 sec. response (1) . 1-1/8" length.

RB824 Spare Band package of 2

RTC825 Heavy-Duty Curved Surface Band Probe for large diameter rolls or other curved surfaces. Surface speed limit 600ft/min. Place flexible band in static or sliding contact with surface. Heavy-duty band, 1/4" x 5", supported by flexible spring plate. Also recommended for pipe surfaces. Limit to 600°F, 12 sec. response (1) .

RTC826 Penetration Probe penetrates semi-fluid materials like plastic, rubber and wax to 1200°F. 4 sec. response (2) .

RTC827 Ingot Probe gives fast measurement of hot, soft aluminum, or brass ingots. Upper temp. limit: 1800°F. 1 sec. response (1) .

RTC827A Heavy Duty Ingot Probe gouges through surface crusts of copper and aluminum ingots. Close-coupled to minimize resistance errors. Upper temp. limit: 1800°F. 3 sec. response (1) .

RTC828 Immersion Probe for liquids including corrosive fluids to

1800°F. 12" stainless steel shank. 6 sec. response (2) For 24" shank, specify RTC828-24.

RTC842 Roll Surface Probe for moving surfaces up to 600ft/min. such as heating rolls, moving strip steel, rubber or paper. Head can be rotated 90°.

Upper temperature limit: to 450°F. 5 sec.

response (1) .

RTC877 Moving Surface Probe with Teflon bars for moving surfaces or rotating rollers to

2600ft/min. Reduced friction keeps temperature rise to less than 1°F on smooth surface. Upper temp. limit: 450°F. 5 sec. response (1) .

RTC877 for 16" diameter rolls and flat surfaces

RTC827A

Heavy Duty Ingot

Probe

RTC877-1 for 6" to 12" diameter rolls

RTC877-2 for 4" to 8" diameter rolls

RB877 Spare Band (1)

Response time legend (to 99% of 212°F): (1) clean hot plate surface (2) immersion in boiling water

TC829-12 in use with

2500MVX Meter, page 10.

RTC825

Heavy-Duty Curved

Surface Band Probe

RTC822

RTC842

RTC826

RTC827

170 Years of Continued Innovation

TC829

Extension

Handle

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

Thermocouple Meters

New Probes

Custom Probes

New! RTD Sanitary Probe

SPD Sanitary Probe Shown with Cable #12071-02

• Single 4 wire or Dual 3 wire RTD Sensors

• “No Tool Required” IP-68 rated connector

• 316 Stainless Steel construction

• Vibration resistant

S

ANITARY

Single Sensor Dual Sensor

SPSXXYY

P

ROBES

SPDXXYY

• Flange available in 1.5", 2.0", 2.5", and 3.0".

Insert Flange Code: 1.5, 2.0, 2.5, or 3.0 in place of XX (in table, above)

• Standard Stem Lengths in 2.5", 3.5", 4.5" and 6.0" (Other lengths available)

Insert Stem Length Code: 2.5, 3.5, 4.5, or 6.0. in place of YY (in table, above)

• Optional Cables (order separately):12071-01 - 4 conductor cable, SPS Series

(Both cables are 4 meters in length) 12071-02 - 6 conductor cable, SPD Series

New! T-Handle Piercing Probe

• 304 Stainless Steel Shank

• Equipped with “Mini-T/C Female” connector

• 8" Shank length

• Single or Dual Sensor Type K

Thermocouple Probe

• Wide range of applications such as

Canning, Meat Processing

PTK T-Handle Piercing Probe shown at left with Model DST200C Digi Stem

Thermometer, and CA1KMM06 Cable

(ordered separately).

Close up of T-Handle Piercing Probe showing thermocouple connection on side of handle.

T-H

ANDLE

P

IERCING

P

ROBES

Single

PTKS-8

Dual

PTKD-8

TC882R

Spring-Loaded Bayonet Probe

TC882S Spring-Loaded Bayonet Probe

Wahl Will Custom-Engineer and Build

Probes To Your Requirements.

If you have a unique requirement for temperature probes, Wahl will custom-engineer and build them for you. We have produced more than 2000 custom designs.

292 RTD Sealed Immersion Probe

TC886 Magnetic Surface

Probe

TC881 Thermocouple Spring-Loaded

Thermowell Probe

TC881 Spring-Loaded Thermowell Probe Provides contact in thermowell to reduce time lag. Available as Type K thermocouple and 100-ohm RTD.

Stainless steel 6" shank .250" diameter. TC881-9 9" shank TC881-12 12" shank.

TC882 Spring-Loaded Type K TC Bayonet Probe Right-angle and straight.

Quick disconnect. 3' armored cable. 1/2" shank x .125" diameter.

TC882R - Right Angle, TC882S - Straight, TC882R-1, TC882S-1 - 1" Shank.

It’s simple: FAX a sketch of dimensional requirements, environmental conditions, temperature limits, output (TC or RTD) and quantity. We will promptly return an engineered design and price quotation.

In addition to the thermocouple and platinum-RTD probes shown throughout, Wahl offers off-the-shelf probes for immersion in liquids and semi-fluids, insertion, penetration, air and gas calibration, surface measurements, and other applications.

TC886 Magnetic Surface TC Probe Fast response 2-lb. pull magnet attaches to ferrous surface. Sensitive, flexible sensor positioned between Teflon bars. 4' cord with connector. Sensor 1" wide x 1-3/8".

292RTD Sealed Immersion Probe For installation in thermowells. Connector head, 5' coil cable and plug to fit Heat-Prober. .250" diameter shank. Available as 100ohm RTD and Type K thermocouple.

05/08

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

17

Dipstick

Thermometer

Systems

Dipstick Thermometer Systems

Measure Molten Metals Quickly, Safely, and Accurately

TC840 Type S Range 3200°F / 1770°C

TC850 Type K Range 2500°F / 1370°C

• Measure ferrous and nonferrous molten metals

• User-selected lance lengths and expendable or reusable tips

• Bright, large displays make readings easy to see

• Maxi-Temp circuit holds peak temperature

• Resolution 1°F/°C; system accuracy ±0.3% or reading

Wahl’s family of Heat-Prober Dipstick high-temperature monitors combine high accuracy, fast-response, comfort, and convenience in rugged, reliable systems.

Special Wahl “dip tip” Type K and S thermocouples are designed to measure molten metals and other high temperature processes.

All systems feature the Maxi-Temp circuit that holds and displays peak temperature reading, even if the expendable tips burn open. System accuracy at molten metal temperatures with a Wahl meter and probe is typically ±9°F with a Type S thermocouple and ±11° with a Type K. Dipstick can be configured with any 2500/1370

Series Meter.

Type S Dipstick Thermometer Systems

Ferrous Metal Systems to 3200°F / 1770°C

Use in molten iron and steel alloys with or without slag for measuring melts in ladles and melt-pots.

Stable readings are obtained in 6-8 seconds. Dipstick comes with one expendable tip. Spare tips are sold separately.

• TC840-1F or C - 48" length dipstick with 45° angle bend (12” from tip), meter with RTC832 expendable tip.

Type K Dipstick Thermometer Systems

Nonferrous Metal Systems to 2500°F / 1370°C

Rugged reusable chrome-tip with Type K thermocouple measures nonferrous metals such as brass, bronze and aluminum, and enclosures such as furnaces, stacks, and ovens. It can be used for hundreds of dips, depending on composition of process materials.

• TC850-1F or C - 55" length dipstick with right angle bend, meter, chrome/iron tip 1/2" diameter x 8" long.

• TC850-2F or C - 72" length dipstick with right angle bend, meter, chrome/iron tip 1/2" diameter x 8" long.

• 10693-2 Replacement 8" chrome/iron tip.

• TC840-2F or C - 60" length dipstick with 45° angle bend (12” from tip), meter and RTC832 expendable tip.

• TC840-3F or C - 60" straight dipstick meter with

RTC832 expendable tip.

• RTC832 Expendable Type S 1-3/4" quartz covered

(exposed) tip for shallow dips, box of 100.

• RTC832S Expendable Type S 1-3/4" quartz covered

(exposed) tip with 12" cardboard sleeve for deeper dips, slag, box 50.

• 10694-2 Replacement 15" chrome/iron tip.

• RTC832SCL Expendable Type S 1-3/4" quartz covered (exposed) tip with 12” ceramic impregnated sleeve for better protection, box 50.

Optional tips for molten gold available.

Expendable Type S tips

RTC832 and RTC832S

TC850 Type K Dipstick for nonferrous metals

18

170 Years of Continued Innovation

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

05/08

700 Series Thermistor and Probes

High accuracy Digital Thermometer is microprocessor based and accepts interchangeable probes.

700MC Meter Range -1.00° to 60.99°C

700MF Meter Range 30.20° to 141.78°F

• Resolution .01°C/°F

• Accuracy ±0.03°C (±.06°F)

• Large 0.33" LED display

• Rechargeable Battery Pack Powered

Apply the latest technological advances to laboratory and field work with Wahl’s exceptionally sensitive and stable Model 700M

Thermistor Heat-Prober. With a resolution of 0.01°C/°F and matching sensitivity, the 700M features ±0.03°C accuracy over a range of -1° to 60.99°C. Available with five precision interchangeable probes (below). The meter design is similar to platinum meter Model 392M Heat-Prober described on page 5.

For complete specifications refer to 392M, page 6.

Thermistor Meter

700 Series

700MC Meter with

LN0253 Screw-in

Immersion Probe

Specifications

Temperature range -1.00° to 60.99°C

Meter accuracy

(30.20

° to 141.78°F)

±0.03°C (.06°F)

Drift (per year) ±0.02°C (0.04°F)

Interchangeability

(probe to probe) 0.10°C (0.18°F)

System accuracy ±0.15°C (0.27°F) when meter and probe are calibrated separately

Readout

Battery Life

0.33 in. high LED

8 hours

Recharge time or: ±0.04°C (0.07°F) when meter and probe are

700M T calibrated together

HERMISTOR

M

ETER

I

NTERCHANGEABLE

P

ROBES

8 hours

700M T

HERMISTOR

M

ETER

I

NTERCHANGEABLE

P

ROBES

Probe Description

LN0250 Flexible Immersion Probe Vinyl sheath and .135" diameter epoxy tip. Small and flexible. 3.6 Second response time*.

LN0252 Button Surface Probe Solid .375" diameter button can be attached with pressure sensitive adhesive tape or epoxy.

Stainless steel contact surface. 1.1 Second response time*.

LN0253 Screw-In Immersion Probe For measurements in pipes, vessels or reactors. 3.6 Second response time*.

Stainless steel shank with 1/8" NPT fitting, 6" standard stem length, 12" option, order LN0253-12.

LN0255 Immersion Probe For liquid and semi-solids. Stainless steel. For foods, chemical, pharmaceutical and laboratory work.

0.1°C interchangeability, 6" long stem, .125" diameter. For 12" length option, order LN0255-12. 1.0 Second response time*.

LN0255A Immersion Probe With .05°C interchangeability, 6" shank, .250" diameter. For 12" length option, order LN0255A-12.

*Response time is based on 63% in water moving at 3 feet per second.

Probes are supplied with 5 foot cord and plug to connect with meter

LN0255 Immersion Probe

LN0250 Flexible Immersion Probe

LN0252 Button Surface Probe

LN0253 Screw-In Immersion Probe

WARRANTY

05/08

Calibration Services Available

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

19

20

The World’s Finest Manufacturers of

Temperature, Pressure, and Humidity Instrumentation

C

ALIBRATION

S

ERVICES

Wahl designs and manufactures to the most stringent quality standards. We provide certified, traceable calibration data in support of companies whose requirements include meeting ISO 9000, FAA and FDA quality standards. Calibrations to both IPTS-68 and ITS-90 are available. Choose from two levels of calibrations services to meet your quality system requirements.

STANDARD CERTIFICATION: Unit is calibrated to factory specifications using NIST traceable equipment. Unit is provided with:

Certificate of Conformance*- Statement that our product meets published specifications. Included when you buy a new product.

Calibration Sticker*- (or tag) Advising you of the date your instrument(s) was/were calibrated, and the suggested date for its next calibration. This is provided when you buy a new product and when you return a product for calibration. (

*Most Products)

Why you need to

Calibrate your Instruments

NIST TRACEABLE TEST REPORT: Unit is calibrated to factory specifications using NIST

Traceable equipment. Unit is provided with:

NIST Traceable Test Report - Our quality Management system is certified to conform to ISO9001:2000. We maintain a calibration system in conformance with ANSI/NCSL Z-540 and MIL-STD-45662A.

• Increase customer satisfaction with consistent products.

• To comply with quality standards.

"Before" and "After" Data with Out of Tolerance conditions noted.

Calibration Sticker (see above).

• Improve product quality.

R

EPAIR AND

O

THER

S

ERVICES

• Ensure traceability throughout your entire manufacturing process.

REGISTER YOUR PRODUCT: Registration is fast and easy. In about a minute you can register your product for Warranty Protection and our Calibration Reminder Service to keep your QC Program in compliance. Go to www.palmerwahl.com/register.

REPAIR SERVICES: Palmer Wahl offers repair and calibration services on most products we sell. Contact Customer Service for pricing, and an RMA. Please see note below.

Detailed Repair Report - Available upon request, this report provides details of evaluation and repairs made.

Custom Points - Palmer Wahl will calibrate your instruments at your specified temperatures.

Special Requests - When calibrating your instrument, our experienced personnel will help you to achieve the level of quality that you need in your facility.

Note: You must have a Return Merchandise Authorization Number, (RMA) before returning a product for repair or calibration. To obtain an RMA, please call Customer

Service at 1-800-421-2853 or go to www.palmerwahl.com and click on Service > Product

Return Request.

• Palmer Wahl offers a complete line of Calibrators to integrate all the necessary functions for adjustment and maintenance of your process.

• Our products are easy to use and

Palmer Wahl is there to help, every step of the way.

• Go to: www.palmerwahl.com >

Test & Calibration.

Wahl Heat Probers ® are distributed by:

Palmer Wahl Warranty

Manufacturer warrants all products listed in this catalog to be free from defects in material or workmanship under normal use and service. The Manufacturer agrees to repair or replace any product which upon examination is revealed to have been defective due to faulty workmanship or material if returned to our factory, transportation charges prepaid, within the product specific warranty period stated in the catalog by the manufacturer. This warranty is in lieu of all other warranties, expressed or implied and of all obligations or liabilities on its part for damages including but not limited to consequential damages, following the use or misuse of instruments sold by the Manufacturer. No agent is authorized to assume for manufacturer any liability except as set forth above.

234 Old Weaverville Road • Asheville, North Carolina • 28804-1228

ISO9000:2001 CERTIFIED

Phone (800) 421-2853 • (828) 658-3131 • Fax (828) 658-0728 • Email: [email protected]

www.palmerwahl.com

PW1220 05/08

NEW!

TM602 • TM612 • TM630

Pocket Thermometers

Wahl

Pocket

Thermometers

Measurement with Thermocouple, RTD or Thermocouple and RTD

Rugged IP54 Construction for On Site Use

Metrology and Control Tool

User friendly and robust, the New Wahl TM Series Pocket Thermometers are designed to simplify temperature transmitters and probes maintenance and commissioning. They feature 0.02% Accuracy and measure in

Thermocouple and/or RTD’s. Resolution is programmable for better reading by user with up to 1m

or 1

µ

V.

TM602: Pocket Thermocouple Thermometer

TM612: Pocket RTD Thermometer

TM630: Pocket Thermocouple and RTD Thermometer

FEATURES

• Well adapted for different process job procedures due to their wide choice of ranges and specific functions such as data recording

• High Accuracy: 0.02% of Reading

• Very low temperature coefficient: 15 ppm / °C in thermocouples and

10 ppm / °C in resistance

• Accuracy is maintained even in harsh environmental conditions

• Measurement of 14 thermocouples and 12 RTD types

• Display in °C, °F, mV and Ohms

• Data Recording and Onscreen analysis

Language - 5 user selected languages (English, French,

Spanish, German and Italian).

Display - Graphical LCD with adjustable contrast and backlight.

Display Resolution - 3 user selectable resolutions (up to 3 decimal places: High, Middle or Low resolution.

Date and Time Display - Continuously displayed.

TM630

Statistics - Maximum, Average, and Minimum are displayed. Reset function allows re-calculating of the values.

Hold - Freezes the display.

Filter - A filter can be applied to avoid fluctuation of the value.

WARRANTY

GRAPHIC DISPLAY

TM Series Pocket Thermometers use a graphic display making programming and reading easier.

Function Menu Calibrated Sensor Menu Reading Display

03/07

Specifications subject to change without notice

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

1

Wahl

Pocket

Thermometers

NEW!

TM602 • TM612 • TM630

Pocket Thermometers

THERMOCOUPLE SPECIFICATIONS

2

DC VOLTAGE

Function

IN

Range

±100mV

Resolution

1µV

Accuracy / 1yr

0.020%R + 3µV

Temperature Coefficient < 15 ppm R / °C from 0°C to 18°C and 28°C to 50°C.

Range

-10mV / 100mV

Sensor

K

T

J

E

R

S

B

U

L

C

N

Platinum

Mo

NiMo/NiCo

TEMPERATURE WITH THERMOCOUPLES

IN Range

-250°C to -200°C

-200°C to -120°C

-120 °C to -50°C

-50°C to +1372°C

-250°C to -200°C

-200°C to -50°C

-50°C to +400°C

-210°C to -200°C

-200°C to -120°C

-120°C to +60°C

+60°C to +1200°C

-250°C to -200°C

-200°C to -100°C

-100°C to +450°C

+450°C to +1000°C

-50°C to +150°C

+150°C to +550°C

+550°C to +1768°C

-50°C to +150°C

+150°C to +550°C

+550°C to +1768°C

+400°C + 900°C

+900°C + 1820°C

-200°C to -100°C

-100°C to +600°C

-200°C to -100°C

-100°C to +900°C

-20°C + 900°C

+900°C + 2310°C

-240°C to -190°C

-190°C to -110°C

-110°C to -0°C

+0°C to +1300°C

-100°C to +1400°C

0°C to +1375°C

-50°C to +1410°C

0.5°C

0.2°C

0.1°C

0.2°C

0.1°C

0.05°C

0.05°C

0.05°C

0.05°C

0.05°C

0.05°C

0.05°C

0.05°C

0.1°C

0.05°C

0.05°C

0.05°C

0.50°C

0.20°C

0.10°C

Resolution

0.20°C

0.10°C

0.05°C

0.05°C

0.2°C

0.05°C

0.05°C

0.1°C

0.1°C

0.2°C

0.1°C

0.05°C

0.05°C

0.05°C

0.05°C

0.05°C

Accuracy/1Yr

0.90°C

0.3°C

0.02% R + 0.12°C

0.02% R + 0.11°C

0.80°C

0.25°C

0.02% R + 0.09°C

0.30°C

0.25°C

0.020% R + 0.11°C

0.020% R + 0.09°C

0.55°C

0.20°C

0.020% R + 0.07°C

0.020% R + 0.05°C

0.95°C

0.40°C

0.020% R + 0.30°C

0.85°C

0.020% R + 0.4°C

0.020% R + 0.3°C

0.95°C

0.50°C

0.35°C

0.20°C

0.30°C

0.20°C

0.30°C

0.020% R + 0.15°C

0.60°C

0.25°C

0.15°C

0.020% R + 0.07°C

0.3°C

0.020% R + 0.10°C

0.020% R + 0.35°C

CJC Accuracy: ±0.3°C

Temperature Coefficient < 10% of Accuracy / °C

Specifications @23°C ±5°C, and between 45% and 75% of relative humidity.

170 Years of Continued Innovation

Specifications subject to change without notice

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

03/07

NEW!

TM602 • TM612 • TM630

Pocket Thermometers

Wahl

Pocket

Thermometers

RTD SPECIFICATIONS

Function

IN

Range

400 Ohm

3600 Ohm

Resolution

RESISTANCE

Accuracy / 1yr Range

1 m Ω 0.012% R + 10 m Ω

10 m Ω 0.012% R + 100 m Ω 0

0 Ω to 400 Ω

Ω to 3600 Ω

Temperature Coefficient < 10 ppm R / °C from 0°C to 18°C and 28°C to 50°C.

RESISTIVE PROBES

Sensor Range

Pt 50 ( α = 3851)

Pt 100 ( α = 3851)

Pt 100 ( α = 3916)

Pt 100 ( α = 3926)

Pt 200 ( α = 3851)

Pt 500 ( α = 3851)

Pt 1000 ( α = 3851)

Ni 100 ( α = 618)

Ni 120 ( α = 672)

Ni 1000 ( α = 618)

Cu 50 ( α = 427)

Cu 50 ( α = 428)

-220°C +850°C

-220°C +850°C

-200°C +510°C

-210°C +850°C

-220°C +1200°C

-220°C +1200°C

-220°C +760°C

-60°C +180°C

-40°C +205°C

-60°C +180°C

-70°C +150°C

-50°C +150°C

Temperature Coefficient < 10% of accuracy / °C

Accuracy is given for a 4 wire connection

Sensor accuracy is not taken into account in the accuracy

Automatic detection: 2, 3 or 4 wires

Measuring current: 0.65 mA

Resolution

Measurement

0.01°C

0.01°C

0.01°C

0.01°C

0.01°C

0.01°C

0.01°C

0.01°C

0.01°C

0.01°C

0.01°C

0.01°C

Accuracy/1Yr

Measurement

0.012% + 0.06°C

0.012% + 0.05°C

0.012% + 0.05°C

0.012% + 0.05°C

0.012% + 0.12°C

0.012% + 0.07°C

0.012% + 0.05°C

0.012% + 0.03°C

0.012% + 0.03°C

0.012% + 0.03°C

0.012% + 0.18°C

0.012% + 0.06°C

Notes

Automatic detection: 2, 3 or 4 wires

Automatic detection: 2, 3 or 4 wires

Specifications @23°C ±5°C, and between 45% and 75% of relative humidity.

03/07

Specifications subject to change without notice

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

170 Years of Continued Innovation

3

Wahl

Pocket

Thermometers

NEW!

TM602 • TM612 • TM630

Pocket Thermometers

MEASUREMENT FUNCTIONS

Calibrated Sensors: A database can be created to design curves for sensors after calibration in relation with the corrections shown on a calibration report.

Scaling: This operation allows correction of probe errors.

Scaling is performed using up to 10 segments, in order to fit with the real calibrated value.

Data Recording: Data is recorded either manually on event or automatically with programmed frequency. Data is time stamped, and can be displayed as list or curves.

ENVIRONMENTAL CONDITIONS

Reference Conditions: 23°C ±5°C, Relative Humidity: 45% to 75%

Nominal Operating Conditions: -10°C up to +50°C, Relative

Humidity: 20% up to 80% non-condensing

Maximum Operating Conditions: -10°C up to +55°C, Relative

Humidity: 10% up to 80% (70% at 55°C)

Maximum Storage Temperature: -30°C up to +60°C (without battery)

Electrical Security: EN 61010

Electromagnetic capability: EN61326

Thermocouple Connection: mini compensated connector

RTD Connection: 4 pin round connector or 4 banana plugs

USB Connection: for PC connection (software upgrade and application with DATACAL)

Power Supply: 4 AA batteries. Optional rechargeable battery pack with charger is available

Battery Life: 40 hours

Dimensions: (without protection boot): 6.18 x 3.35 x 1.77

inches (157 x 85 x 45mm)

Weight: 10.79 ounces (306 grams)

IP Rating: IP 54 according to EN 60529

Included Accessories: Protective Boot, 4 AA Batteries, User

Manual on CD Rom and Wrist Strap

Optional Accessories: Rechargeable Batteries and Battery

Charger, NIST Calibration Certificate, and Carrying Case

ORDERING INFORMATION

TM602: Pocket Thermocouple Thermometer

TM612: Pocket RTD Thermometer

TM630: Pocket Thermocouple and RTD Thermometer

12436-01: Rechargeable Batteries and Battery Charger

12436-05: TM Series Carrying Case

NIST: NIST Certification TM602

NIST: NIST Certification TM612

NIST: NIST Certification TM630

Optional Thermocouple and RTD Probes available in the Wahl Heat Prober® catalog.

4

170 Years of Continued Innovation

WARRANTY

Specifications subject to change without notice

(800) 421-2853 • FAX (828) 658-0728 • www.palmerwahl.com

03/07

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement