Siemens TC63 Technical data

IGS6-10 GSM Interface Unit
Siemens Add-on Modem for
Sintony 60
Configuration Manual
Fire Safety & Security Products
Siemens Building Technologies
Liefermöglichkeiten und technische Änderungen vorbehalten.
Data and design subject to change without notice. / Supply subject to availability.
© 2007 Copyright by
Siemens Building Technologies
Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte
an und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder
außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights
and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our
prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
Contents
1
Product description ................................................................................5
2
Technical data .........................................................................................6
3
Connections ............................................................................................7
4
4.1
4.2
4.3
4.4
4.5
Pre-installation requirements ................................................................8
Cellular account ........................................................................................8
SIM card....................................................................................................8
TCP / IP.....................................................................................................8
Hardware...................................................................................................8
Software ....................................................................................................8
5
5.1
5.2
Installation ...............................................................................................9
Configuration software ..............................................................................9
Unit..........................................................................................................10
6
6.1
6.2
6.3
6.3.1
6.3.2
6.4
6.4.1
6.4.2
6.4.3
6.5
6.6
Configure the unit .................................................................................11
Prerequisites ...........................................................................................11
Starting the software ...............................................................................11
Configuration methods............................................................................12
Local control via COM.............................................................................12
Remote mode configuration....................................................................13
Protocols .................................................................................................14
TCP/IP.....................................................................................................16
Contact ID configuration .........................................................................19
SMS configuration...................................................................................20
Remote access configuration..................................................................21
Fast SMS configuration...........................................................................23
3
Siemens Building Technologies
Fire Safety & Security Products
12.2007
4
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Product description
1
Product description
The IGS6-10 is a GSM add-on modem. It connects to the Sintony bus and can
function as a second dialer or backup dialer to the one in the control panel.
When an event or alarm takes place the unit can either report to a central station or
send an SMS message to a cellular phone.
The following reporting media can be used simultaneously:
Reporting media Reporting format
TCP/IP
CID
GPRS
CID
GSM
SMS
Features
z Full report for all the events of the IC60.
z Reporting formats in CID and SMS.
z Reporting up to 4 subscriber phones in each format.
z Communication via GSM Quad Band 900 / 1800 MHz or 850 / 1900 MHz based
on Siemens TC63 engine.
z Rechargeable lead acid 12 V/1.3 Ah backup battery.
z Tamper alarm is triggered if cover is opened or the unit is torn from the wall.
z Programming the unit by a PC via USB Port and via GPRS.
z Two operation modes:
1. Backup for the control panel dialer.
2. Parallel reporting channel.
5
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Technical data
2
Technical data
Radio frequency
Operating frequency
850 MHz, 900 MHz, 1800 MHz, 1900 MHz
Output power
Class 4 EGSM850: 2 W
Class 4 EGSM900: 2 W
Class 1 EGSM1800: 1 W
Class 1 EGSM1900: 1 W
GPRS multi-slot class
12
Modem Type
GSM Quad-Band
Internal Antenna
Tri-Band
Communication services
TCP/IP
Stack access via AT commands
Internet services
TCP, UDP, HTTP, FTP, SMTP, POP3
GSM Report Modes
TCP/IP over CID
GPRS over CID
GSM over SMS
Interfaces
Antenna connector
U.FL-R-SMT
SIM card
3 V, 1.8 V
Bus
IC60
Power consumption
Power supply
10.5 - 14.5 V DC
Battery
12 V 1.3 Ah Lead Acid
Current consumption
Standby: 100 mA
Battery charging control
Current limited 260 mA, 1.6 A fuse protected
Max. 200 mA
Inputs 1& 2
Reprogrammed SMS
Output 1
Active "Low" while there is a network error (GSM
fail, low RSSI)
Environmental conditions:
Operation temperature
-10 to +50 °C
Storage temperature
-20 to +60 °C
Humidity (EN60721)
< 85 % r.h., non condensing
Approvals
R&TTE, FCC, UL, IC, GCF, PTCRB, CE, Local
approvals and network operator certifications
6
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Connections
3
Connections
1
NET: turns green when there is communication with TCP/IP server.
Status LEDs
BUS: blinks yellow on BUS communication with control panel.
FAIL: Blinks or stable in red on network error (problem with SIM card,
GSM network…).
2
SIM card holder
SIM card used for the GSM modem.
3
Antenna
Cellular phone antenna connector.
4
Tamper Switch
Activates alarm if cover is removed.
5
Program Connector
Connector for connecting the inputs and outputs.
6
CONFIG PORT 1
Serial port and connects to a PC or laptop.
7
Battery Connector
Backup rechargeable battery 12 V/1.3 Ah lead acid.
8
Bus Connector
For communication with the control panel.
9
Power LED
Red when power ok.
10
GSM modem
Siemens TC63 GSM modem
11
GSM Service LED
Blinks yellow when GSM service connected.
12
13
14
Output 1&2
Terminal block
Gnd
Input 1&2
7
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Pre-installation requirements
4
Pre-installation requirements
4.1
Cellular account
You need to open a cellular account with your cellular service provider to enable
the cellular gateway module on your unit.
On opening the account you receive the following:
– A cell-phone number
– GSM/GPRS SIM card
4.2
SIM card
When ordering the GSM/GPRS SIM card, be sure to specify to the cellular service
provider that the SIM card needs to be activated for GPRS data services (unlocked). In some locations you might receive a password for this, and maybe even a
different number.
4.3
TCP / IP
The IP functionality is designed for use with a CMS and requires support from CSC.
For TCP/IP connection you need:
– APN (Access Point Name)
APN is the name of an access point for GPRS. It identifies an external network
that is accessible from a terminal. An APN has several attributes associated with
it that define how you can access the external network at that point.
Speak to your local service provider to get the ATN of your network.
– IP of target receiver.
4.4
Hardware
– PC or laptop with a USB port
4.5
Software
– Windows XP or VISTA
8
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Installation
5
Installation
5.1
Configuration software
1.
Double Click the installation file.
Î
The InstallShield Wizard opens.
2.
Choose the destination location.
3.
Click Next.
Î
4.
The installation starts.
After the installation click Finish.
Î
The configuration software IGS6-10 is installed.
9
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Installation
5.2
Unit
z Before installing the hardware we strongly recommend that you pre-program the unit. This is done
using a PC or a laptop running the configuration program and using the USB cable supplied.
z If the GSM unit is installed as a backup module, it should be installed at another location than the
panel.
Disconnect the mains and the backup battery.
1.
Choose a suitable location for the unit within 1 to 20 meters from the IC60.The
location must be within the secured area.
2.
Using the paper template drill 4 holes in the wall to mount the unit.
3.
Using four screws, fix the unit to the wall.
4.
Connect the unit to the Sintony bus: POS, NEG, CLK, DATA
(see section 3: Connections).
z If external power supply is used to power the IGS6-10, the GND of the bus (from control panel)
must be connected with the GND of the external power supply.
z The 2 wires are connected on the same terminal (NEG).
5.
Insert the SIM card into the SIM card housing.
6.
Verify that the antenna is connected.
7.
Power on the IC60.
8.
Connect the backup battery.
10
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
6
Configure the unit
6.1
Prerequisites
z To ensure reporting disable the setting "No Keypad Indication if Armed":
P25E13E 5E in the IC60.
z Disable the setting: P168E1-16E 4E in the IC60.
z Starting the software is only possible if the IGS6-10 modem is connected to the
PC.
6.2
Starting the software
1.
On the desktop, double-click the icon
2.
Select a language.
3.
Click the Next button.
Î
.
The following window will open:
If the SIM Card has a PIN Code, the following window will appear. If not forward to next chapter.
4.
Type the correct PIN code.
5.
Press OK.
11
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
6.3
Configuration methods
There are 2 ways to configure the modem:
– Local control via COM: for configuration via local PC (USB).
– Control modem via Data Link: for remote configuration via GSM data call
1
2
Fig. 1
6.3.1
Configuration method
Local control via COM
Fig. 2
Configuration method: Local control via COM Port
Prerequisites:
z The USB cable is connected.
1.
Start the program.
2.
Press the button Local control via COM (see Fig. 1).
3.
Press Next.
12
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
6.3.2
Remote mode configuration
Disconnect the master unit (the modem you are dialing from) from the keypad bus of the IC60.
Fig. 3
Configuration method: Remote mode configuration
Prerequisites:
z The SIM card has been inserted in both modems.
z A network connection is established.
z The access code is available.
Before making a remote configuration, a local configuration has to be made using the USB cable (see
chapter 6.4.1: Local control via COM).
1.
Start the program.
2.
Press the button Control modem via Data Link (see Fig. 1, page 12).
3.
Enter the phone number of the "far end" unit (the one that will be configured
remotely),
4.
Enter the password.
5.
Press Next.
Î
The modem is dialing (see also Fig. 3):
13
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
6.4
Protocols
The following protocols can be used simultaneously:
Reporting
media
Reporting format
Reporting priority
Symbol Section
TCP/IP
CID
1
6.4.1
GPRS
CID
2
6.4.2
GSM
SMS
3
6.4.3
If both GSM and TCP/IP protocols are selected, the data will be sent only via TCP/IP. If TCP/IP fails,
the data will be sent via GSM.
1.
Select the required protocols from the Available protocols.
2.
Move it to the Selected protocols by pressing
Î
.
The required protocols re listed in the field Selected protocols.
The order of configuration windows depends on the order of the protocols in the selected protocols list.
I.e. if the order of the protocols is TCP/IP, SMS, and CID so the first configuration window will be
Internet configuration, the second will be SMS configuration, etc…
3.
Click the
Î
button.
The modem status is displayed (in the following Fig. the firmware version of
the IGS6-10, the operator and the RSSI level):
14
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
If there is a network error (see section 3: Connections), this window pops up automatically.
4.
Click OK.
Î
The window will be closed
15
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
6.4.1
TCP/IP
Prerequisites:
z APN (see section 4.3: TCP / IP) of your service provider.
z Domain name or an IP address.
1.
Click the
Î
button.
The window Internet configuration will open:
Fig. 4
Internet Configuration
Button or Field
Description
Access point name
Displays the internet service provider (APN address)
Event’s table
Displays the available events to trigger the IGS6-10 modem.
Add
Add a new entry to the list.
Remove
Removes an unwanted number.
Properties
Edit the existing account and IP Address (or phone number)
Up
The top number is dialed first and if unavailable continues to the next in
sequence. Use these buttons to move the numbers up and down the list
so that you can place them in the required sequence.
Down
There are 2 ways to operate the IGS6-10 modem:
– As backup
– Independently
Backup
The backup will operate at the following cases:
z Physical loss of phone line.
z Dialer: Unanswered.
z Dialer: No Kiss-off.
If you want the IGS6-10 modem to operate only as backup to PSTN and the integrated dialer of the IC60:
2.
Disable the setting “Enable Dialer: P175E 1E in the IC60.
3.
Select the checkbox Only while PSTN Fail/Dialer Failure! (this option can be
checked separately for every protocol).
16
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
Independently
If you want the IGS6-10 modem unit to operate independently of the PSTN of the
control panel:
4.
Uncheck the checkbox Only while PSTN Fail/Dialer Failure!
Î
The IGS6-10 unit will transmit the events together with the telephone line of
the control panel.
.
5.
To add new IP addresses click the button
6.
Enter a 4 digit ID number for the IGS6-10 modem in the account field.
7.
In the next field enter a domain name or an IP address.
8.
Click the button
Î
9.
.
The new IP address has been added to the list.
Enter the Access point name (APN) of your service provider.
10. To add events to trigger a transmission click the button
Î
.
The window Event ListView opens:
17
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
Fig. 5
Events in simple mode
There are two modes:
z Simple mode: The available events list has only common events (see Fig. 5).
z Advanced mode: The available events list has all events (Fig. 6).
Fig. 6
Events in advanced mode
18
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
11. Choose a mode.
12. Double-click an event from the Available events list
-ORSelect one and then click the button
Î
.
Multiple events are now shown in the field Events to send. Any one of these
events causes the IGS6-10 modem (if enabled) to transmit the event information.
13. To load a configuration: click the button
.
14. To save the current configuration on your PC: click the button
.
You can make multiple configurations and save them on your PC. Speak with your service provider
which typical data should be saved.
15. Click the button
Î
6.4.2
.
The Internet configuration is complete.
Contact ID configuration
1.
Click the button
Î
The window Contact ID configuration opens.
Fig. 7
2.
.
Contact ID configuration
Configure the window Contact ID configuration as described in section
6.4.1. Exception: Entry of APN not required.
19
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
6.4.3
SMS configuration
1.
Click the button
Î
The window SMS configuration opens:
Fig. 8
2.
.
SMS configuration
Configure the window SMS configuration as described in section 6.4.1.
Exception:
– Entry of APN not required.
– Instead of a domain name or IP address you have to enter a telephone
number.
The SMS texts are in standard text and in English only.
20
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
6.5
Remote access configuration
In this window you can setup the remote configuration.
There are 2 security levels:
z Only password
z Password and telephone number. The telephone number will be used to get
connection from the local unit to this unit, in order to figure this unit remotely.
Make sure that your telephone can display the incoming phone number.
1.
Click the button
Î
.
The window Remote access configuration opens:
2.
If remote access is not to be allowed, press the button Remote access disable.
3.
If the authentication requires a password, press the button Check password.
Î
The window Enter password opens:
If previously no password was used, the field old password will not appear.
21
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
4.
Enter the desired password (max. 14 characters).
5.
If the authentication requires a password and a phone number, press the button Check password and phone number.
Î
The window Add phone number opens:
6.
Enter the desired password (max. 9 characters).
7.
Enter the phone number.
8.
To erase the password at this entry remove the phone number from the list.
9.
Click the button
Î
.
You will get back to the configuration window.
22
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Configure the unit
6.6
Fast SMS configuration
This is the window to customize the SMS that will be triggered at Input 1.
When Input 1 is shorted to ground (pulse), the custom SMS will be sent to the
phone number entered in the SMS configuration window. If the SMS protocol is not
selected in the field Selected protocols, then no SMS will be sent.
As an additional feature, when this input is shorted to ground, an event "General
Alarm" will be sent in CID (number 140), beside the custom SMS.
For the CID event to be sent, select the CID protocol in the field Selected
protocols. This event will be sent to the phone numbers entered in the contact ID
configuration window. If there was a kiss-off of this event, the reporting will stop. If
there wasn't a kiss-off of this event, the event will be reported to the next phone
number (if there is any). If you leave these fields blank, then no SMS and no CID
will be sent.
1.
Click the button
Î
The window Fast SMS opens.
2.
Make you configuration.
3.
Click the button
Î
.
.
The configuration is finished.
23
Siemens Building Technologies
Fire Safety & Security Products
12.2007
Issued by
Siemens Building Technologies
Fire & Security Products GmbH & Co. oHG
D-76181 Karlsruhe
www.siemens.com/homesecurity
Document no.
A6V10075156
Edition
12.2007
© 2007 Copyright by
Siemens Building Technologies
Data and design subject to change without notice.
Supply subject to availability.