Datasheet | EverFocus EDSR100H Technical data

Add to my manuals
39 Pages

advertisement

Datasheet | EverFocus EDSR100H Technical data | Manualzz

EKB500

DVR and Telemetry Keyboard

FW 1.5

New operating concept !

1 SAFETY WARNINGS

• Do not place the device near to heaters, furnaces, other heat sources or under direct solar irradiation.

• Operate the device only in locations providing the tolerable operating temperature range 0°C~40°C.

• For cleaning, make sure the device is plugged off and only use a damp cloth without acid detergent.

• Install the device only in dry and dustproof surroundings. Protect the device against any liquid’s penetration.

• Avoid the penetration of any artefacts, e.g. through ventilation slots.

• Do not open the device yourself. In case of malfunction, contact your local installer or dealer. Unauthorized opening of the device will annul the warranty claim!

• Use the device only for purposes described in this manual.

• Operate the device only with the power source indicated in the technical data.

ATTENTION! This is a class A product which may cause radio interference in a domestic environment; in this case, the user may be urged to take adequate measures.

This equipment has been tested and found to comply to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/ TV technician for help.

This Product is RoHS compliant.

WEEE

Your EverFocus product is designed and manufactured with high quality materials and components which can be recycled and reused.

This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.

Please, dispose of this equipment at your local community waste collection/recycling centre.

In the European Union there are separate collection systems for used electrical and electronic product.

Please, help us to conserve the environment we live in!

Ihr EverFocus Produkt wurde entwickelt und hergestellt mit qualitativ hochwertigen Materialien und Komponenten, die recycelt und wieder verwendet werden können.

Dieses Symbol bedeutet, dass elektrische und elektronische Geräte am Ende ihrer

Nutzungsdauer vom Hausmüll getrennt entsorgt werden sollen.

Bitte entsorgen Sie dieses Gerät bei Ihrer örtlichen kommunalen Sammelstelle oder im Recycling

Centre.

Helfen Sie uns bitte, die Umwelt zu erhalten, in der wir leben

!

The information in this manual was current upon publication. The manufacturer reserves the right to revise and improve his products.

Therefore, all specifications are subject to change without prior notice. Misprints reserved.

Please read this manual carefully before installing and using this unit. Be sure to keep it handy for later reference.

2 EKB500_ma_en_rev1 5_3

TABLE OF CONTENTS

1 SAFETY WARNINGS ............................................................................................................ 2

2 INTRODUCTION.................................................................................................................. 4

2.1

FEATURES ...................................................................................................................... 4

2.2

Changes from FIRMWARE 1.5 compared to former Versions........................................ 4

2.3

COMPATIBLE DEVICES .................................................................................................. 4

2.4

DELIVERY SCOPE........................................................................................................... 5

3 OPERATING ELEMENTS....................................................................................................... 6

4 KEYBOARD CONNECTORS................................................................................................... 7

4.1

RS-485 ports.................................................................................................................. 7

4.2

RS-232 connector .......................................................................................................... 7

4.3

POWER CONNECTOR ..................................................................................................... 7

5 INSTALLATION.................................................................................................................... 8

5.1

General RS-485 bus installation.................................................................................... 8

5.2

EPTZ 500 / 1000 / 3000 / 3500 Speed dome camera connection .............................. 10

5.3

ED-2200, ED-2250, Samsung SCC-641, SCC-643 , SCC-6405 connection .................. 10

5.4

Connection of Pelco-D / -P protocol-compatible devices............................................ 11

5.5

EverFocus DVR connection ......................................................................................... 12

5.6

Connection of several keyboards ................................................................................ 14

5.7

START-UP..................................................................................................................... 14

6 MENU SETTINGS ............................................................................................................... 15

6.1

Menu structure ............................................................................................................ 15

6.2

COM PORT SETTING - RS-485 interface setting.......................................................... 16

6.3

DEVICE SETTING ......................................................................................................... 16

6.3.1

Camera setting (changed from FW 1.5) .............................................................. 16

6.3.2

Monitor setting (changed from FW 1.5) ............................................................. 17

6.3.3

DVR Setting.......................................................................................................... 18

6.3.4

Camera List & Delete ........................................................................................... 18

6.3.5

Monitor List & Delete ........................................................................................... 19

6.3.6

DVR List & Delete................................................................................................. 19

6.3.7

Non-listed devices................................................................................................ 20

6.4

KEYBOARD SETTING.................................................................................................... 20

6.4.1

Sub Keyboard Setting .......................................................................................... 20

6.4.2

MENU Password ................................................................................................... 20

6.4.3

Lock password ..................................................................................................... 21

6.4.4

Buzzer ON/OFF .................................................................................................... 21

6.4.5

Joystick calibration .............................................................................................. 21

6.4.6

Keypad test .......................................................................................................... 22

6.4.7

Jog & Shuttle test ................................................................................................ 22

6.4.8

Load default setting ............................................................................................. 22

6.4.9

Firmware update.................................................................................................. 22

7 OPERATION....................................................................................................................... 23

7.1

New EKB-500 operation concept (from Firmware 1.5) ............................................... 23

7.2

MONITOR SELECTION ................................................................................................. 23

7.3

CAMERA SELECTION.................................................................................................... 23

7.4

DVR Password input .................................................................................................... 24

7.5

DVR MAIN MONITOR OPERATION .............................................................................. 24

7.6

PTZ OPERATION / SETUP ............................................................................................ 26

7.6.1

EverFocus EPTZ series ......................................................................................... 27

7.6.2

EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 operation.............. 32

7.6.3

Pelco-D / -P protocol compatible devices’ operation .......................................... 33

7.6.4

LG protocol compatible devices’ operation.......................................................... 35

7.6.5

Panasonic protocol compatible devices’ operation.............................................. 35

8 SPECIFICATIONS .............................................................................................................. 36

9 APPENDIX A: FACTORY SETTINGS ................................................................................... 37

3 EKB500_ma_en_rev1 5_3

2 INTRODUCTION

The EKB 500 universal keyboard was developed for both DVR remote control and telemetry control of speed domes and telemetry receivers. Ergonomic key alignment and the integrated jog/shuttle allow the convenient EverFocus DVR operation. 2 independent RS-485 interfaces enable installations with different telemetry protocols. The new firmware 1.5 allows easier operation also in complex systems with several

DVR and PTZ -cameras.

2.1 FEATURES

• independent loop-through RS-485 ports, programmable with different protocols

• Protocol types: EverFocus, ED2200/2250 (Samsung Electr.), Pelco-D, Pelco-P, Panasonic, LG

• 3-axis joystick for convenient pan / tilt / zoom control

• Jog/Shuttle and separate keypad for DVR control

• Housing allows countersunk installation

• Integrated double-spaced LCD display

2.2 CHANGES FROM FIRMWARE 1.5 COMPARED TO FORMER VERSIONS

1. Main- , Call- and Matrix monitors are operated with same input procedures.

2. Cameras are operated with same input procedure for all types of monitors.

3. The keyboard detects automatically, if a camera has PTZ function or not and signalize PTZ devices with

"PTZ" in the LCD display.

4. The keyboard detects automatically, if a selected monitor is a DVR main monitor and signalizes selected main monitors with "DVR" in the LCD display. All DVR related functions such as playback, search, and multiview are active then.

5. Telemetry control will switch automatically with selecting a camera, also for main monitor operation.

6. The former "DVR-mode" with DVR key is cancelled. DVR key is inactive.

7. Even if only Main monitors are installed in the system, all monitors and cameras of the system have to be defined in setup menu.

2.3 COMPATIBLE DEVICES

Digital video recorders:

EverFocus EDR series (except EDR400/1600)

EverFocus EDVR series

EverFocus PARAGON series

EverFocus EDSR100H/M / 400H/M / 600 / 900 /1600

Speed dome cameras:

EverFocus EPTZ series

EverFocus ED2200 / 2250

Samsung Electronics SCC641 / 643 / 6405

Panasonic

LG (boxed type Autofocus camera series)

VProtect VPTZ series

Pelco-D compatible PTZ devices

Pelco-P compatible PTZ devices

4 EKB500_ma_en_rev1 5_3

2.4 DELIVERY SCOPE

1 x EKB-500 universal keyboard

1 x 12 VDC power supply

1 x RJ-45 connector, 120 Ohm terminated

1 x RS-485 connection kit incl. connector box and 1 m connection cable

1 x manual

1 x packaging

5 EKB500_ma_en_rev1 5_3

3 OPERATING ELEMENTS

1. DVR, MON, CAM

Operation mode toggle key:

D V R : from firmware version 1.5 inactive, function reserved

M O

N : Selection monitor

C A M : Selection camera

2. 3-axis J J J O Y S S T I I I C C K K

Joystick for speed dome and telemetry receiver control

3. LCD display

Double-spaced LCD display for status message display

4. J J J O G / / / S S H U T T L L E E

Operating facility for playback and DVR menu control.

5. DVR control keys

6. Speed dome and telemetry receiver control keys

7. Numeric keypad,

0 0 ~ 9 9

E

C

L

L R

E N T E R

C L L R , E E N T E E R

9 : Numeric keypad for numeric entries

R : : Toggle key for speed dome menu termination

R : Enter key for input confirmation.

6 EKB500_ma_en_rev1 5_3

4 KEYBOARD CONNECTORS

4.1 RS-485 PORTS

EKB-500 provides two independent RS-485 ports with 2 RJ-45 plugs each (loop-through).

Pin assignment:

Pin 1: 12 VDC

Pin 3: RS-485 +

Pin 6: RS-485 -

Pin 7: Ground

Pin assignment RJ-45 connector connector box

Delivery comprises a connector box for RS-485 and 12 VDC power supply connection enabling power supply connection either directly to the EKB 500 keyboard or through the connector box.

4.2 RS-232 CONNECTOR

The 9-pin Sub-D connector is used for service purposes, e.g. keyboard update with new firmware.

4.3 POWER CONNECTOR

Use the 5,5 mm socket for connecting the 12 VDC power supply. Centre pin is + 12 VDC. The power supply may be installed either through this socket or through the included connector box.

7 EKB500_ma_en_rev1 5_3

5 INSTALLATION

5.1 GENERAL RS-485 BUS INSTALLATION

EKB 500 uses an RS-485 simplex wiring; the signal is transferred via a single twisted pair line.

CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal application. A shielded cable should be used if the installed cables are expected to be highly susceptible to interferences.

The number of devices installed in one bus is limited to 32 (expandable through signal distributors), while max. 8 EKB 500 keyboards may be installed in one system.

Basically, the bus should be created by serial wiring.

Maximum RS-485 bus cable length is 1200 m.

Maximum cable length from box to device is 2m using connector boxes.

Star wiring is permitted only with signal distributors.

WRONG !

RS-485 signal distributors may be used for star wiring. The maximum system cable length can also be expanded by using these distributors, physically providing a new RS-485 bus with 1200 m cable length each at every distributor output.

8 EKB500_ma_en_rev1 5_3

In case the maximum number of 32 bus participants is exceeded, the number of connected devices can be increased by using RS-485 distributors. Each distributor output physically provides one RS-485 bus which enables the additional connection of 31 further devices (the distributor output represents one bus participant itself).

The maximum system expandability depends on the RS-485 address range of the installed devices.

Attention: Most RS-485 signal distributors (e.g. EDA997A) are unidirectional! This means that the signal only flows from the input towards the outputs. Therefore, e.g. the interconnection of several EKB 500 keyboards is not possible with this signal distributor!

9 EKB500_ma_en_rev1 5_3

5.2 EPTZ 500 / 1000 / 3000 / 3500 SPEED DOME CAMERA CONNECTION

Applied protocol type: EVF2 (standard)

5.3 ED-2200, ED-2250, SAMSUNG SCC-641, SCC-643 , SCC-6405

CONNECTION

Applied protocol type: A-Type

10 EKB500_ma_en_rev1 5_3

5.4 CONNECTION OF PELCO-D / -P PROTOCOL-COMPATIBLE DEVICES

Basic functions of speed domes and telemetry receivers compatible to Pelco-D / -P protocol can be controlled with the EKB 500 keyboard if a simplex RS-485 connection option is provided. For general connection, please refer to the chart illustrated above.

Applied protocol type: Pelco-D / Pelco-P (in accordance with dome / receiver)

ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1 at the keyboard, i.e. the address assigned to the dome / receiver in the EKB 500 menu must be 1 below the address set in the dome / receiver itself!

11 EKB500_ma_en_rev1 5_3

5.5 EVERFOCUS DVR CONNECTION

The EKB 500 keyboard can control the following digital video recorders:

EDSR series (despite EDSR100 19" model)

EDR series (MPEG-4 series)

EDVR series

Paragon series

Installation with standard network cable:

For short distances, EKB 500 can directly be connected using a standard network cable (patch cable, uncrossed!).

Connection with EDA998 connector kit:

Place the EDA998 connector kit at the RS-485 bus for easy DVR installation.

12 EKB500_ma_en_rev1 5_3

System settings required for start-up:

Required system settings for DVR control:

DVR:

MENU > RS232/RS485:

RS485

BAUD RATE 9600 BPS > Baud rate must be the same as baud rate of and 9600)

STOP BIT 1

DATA BIT

RS232/RS485 ID

8

1 > RS-485 address, must correspond to EKB 500 setting

DVR setting in EKB 500 menu

EKB-500: (for details, please refer to "6. MENU SETTINGS")

DVR setting:

M E E N U ( S S H I I I F F T +

DVR NAME:

M E E N U key) > DEVICE SETTING > DVR SETTING > E N T E E R :

Selectable DVR number (independent of RS-485 address)

RS485 CONNECTED TO PORT: _ : RS-485 port to which the DVR is connected (1 or 2)

(Complies with DVR menu "RS232/RS485 ID")

Must be in accordance with DVR setting

DVR xxxx changed to E

E N T E R

key to confirm the settings

M E E N U > COM PORT SETTING >

Port:_ (1 or 2)

E E N T E E R R :

Enter the RS-485 port to which the DVR is connected

Input the Port (1 or 2 )

BAUD: 9600<

Protocol: EFV1

Baud rate setting (according to DVR)

Protocol type, setting irrelevant for DVR control> ENTER

Port: 1 Changed

[ENT] to save Press E E N T E R key to confirm the settings

For details and further settings (e.g. matrix monitor setup), please refer to menu description.

13 EKB500_ma_en_rev1 5_3

5.6 CONNECTION OF SEVERAL KEYBOARDS

If several keyboards (max. 8) are used in a system, the RS-485 bus has to be looped through from keyboard to keyboard.

Using both RS-485 interfaces (port 1 and 2), the 2nd bus connection must be effected separately as illustrated above by means of EDA-998 connection kits.

Power supply can be installed either directly at the keyboard or with the included connection box.

5.7 START-UP

After having finished the installation work, switch on the power.

During initialisation (approx. 3 sec.), the firmware version is displayed.

Keyboard

Version 1.5

After initialisation, the following message is displayed:

CAM:0001 MON:0001 > DVR

____ [ CAM / MON ] > PTZ

14 EKB500_ma_en_rev1 5_3

6 MENU SETTINGS

After electrical installation and start-up, both the connected devices and the keyboard itself have to be set up.

Hold the S S H I I I F F T key and press the M E E N U key to enter the keyboard menu.

COM Port Setting

Device Setting

Use the joystick and the from submenus.

E E N T E E R key for menu navigation. Use the E E S C key to leave the menu and return

The "<" icon at the end of the second line indicated further settings to be effected in this menu. Use the

J J J O Y S S T I I I C K to switch between the lines.

Selected settings are displayed blinking. Press E

E N T

E

E previous menu level.

E R

to confirm the setting and E S

S C to return to the

6.1 MENU STRUCTURE

The LCD display menu shows the following structure:

COM Port Setting

Device Setting Camera Setting

Camera List & Delete

Monitor List & Delete

DVR List & Delete

Keyboard setting Sub Keyboard Setting

Jog & Shuttle Test setting

15 EKB500_ma_en_rev1 5_3

6.2 COM PORT SETTING - RS-485 INTERFACE SETTING

Define telemetry protocol type and transmission rate in this menu.

M E E N U > COM PORT SETTING > E E N T

Select port 1 or 2 and confirm with E E

T E E R R

E N T E R .

Port : _ ( 1 or 2 )

Input the port.

Use the joystick to change the value.

Selection: 1200, 2400, 4800, 9600 Baud.

Press E E N T E E R to confirm the setting and E E S C to cancel.

The next menu is used for telemetry protocol setting.

Use the J J J O

Selection:

Y S S T I I I C K to change the value.

EVF-1: V-Protect Speed Dome

BAUD : 9600 <

[ ↑ ↓ ] to change

Protocol : EVF-1

[ ] to change

Pelco-D

Pelco-P

Panasonic

ATTENTION: Protocol type setting is irrelevant for EverFocus DVR control; only baud rate setting is relevant!

Press E E N T E E R to confirm the selection and E E S S C to cancel.

Port : 1 Changed

[ ENT ] to save

6.3 DEVICE SETTING

Connection settings definition for controlled devices.

6.3.1 Camera setting (changed from FW 1.5)

Use this menu to define telemetry cameras and cameras to be assigned to DVR monitors. In difference to former EKB500 firmware versions this setting is valid for Main- and Call/Matrix - Monitors.

M E E N U > DEVICE SETTING > CAMERA SETTING > E E N T E E R

Camera number 1 ~ 9999 (independent of RS-485 address!)

Camera Name : ___

Press E E N T E E R to confirm the setting and E S S C to cancel.

16 EKB500_ma_en_rev1 5_3

Setup of the RS-485 interface connected to telemetry cameras, port 1 or 2, 0 for OFF (fixed camera).

Enter 0 (off) for fixed cameras (numeric entry compulsory).

Press E

E N T E

E R to confirm the setting and E

E S C

to cancel.

If 1 or 2 was selected for PORT, the keyboard will automatically recognise this camera as a PTZ device in operation mode.

Enter the RS485 Address of the PTZ camera (this menu item is skipped for fix cameras).

Setup of DVR and video input to which the camera is connected

(requires a DVR installation in the „DVR Setting“ menu)

Enter any value if no DVR is connected

(numeric entry compulsory).

Press E E N T E E R to confirm the setting and E E S C to cancel.

RS485 Connected to

Port : _ [ 0 (off) ] , 1, 2]

RS485 Address:

001

Video Connected to

DVR : _ _ _ CH : _ _

6.3.2 Monitor setting (changed from FW 1.5)

In this menu all monitors in the system have to be assigned to DVR monitor outputs. In difference to former firmware versions all monitors have to be defined, including main monitors.

All monitors can only be managed by EKB 500 after definition in this menu. By this, an administration of system access rights for this keyboard can be set up, as only monitors defined in this menu are available for access.

M E E N U > DEVICE SETTING > MONITOR SETTING > E E N T E E R

[ [ [ M O N I I I T O R N U M B B E E R ] ] ] , , , entry 1 ~ 99 (independent of DVR monitor number).

Monitor Name : _ _ _

Press E E N T E E R to confirm the setting and E E S C to cancel.

The following menu item allows the monitor assignment to the respective DVR’s monitor output.

Monitor types:

EKB-Display DVR - Monitor out

Video Connected to

DVR : _ _ _ Mon : _ _

Call

M1

M2

M3

Call - monitor

Matrix - monitor 1

Matrix - monitor 2

Matrix - monitor 3

M4 Matrix - monitor 4

Press E E N T E E R to confirm the setting and E E S C to cancel.

Monitor : 1__ changed

[ ENT ] to save

17 EKB500_ma_en_rev1 5_3

6.3.3 DVR Setting

Define the digital video recorders to be controlled by the keyboard in this menu.

DVRs can only be managed by EKB 500 after definition in this menu. By this, an administration of system access rights can be set up, as only DVRs defined in this menu are available for access.

DVR number, entry 1 ~ 999 (independent of

DVR RS-485 address).

Press E E N T E E R to confirm the setting and E E S C to cancel.

DVR Name : _ _ _

Setup of the RS-485 interface to which the

DVR is connected, port 1 or 2.

Press E E N T E E R to confirm the setting or E E S C to cancel.

DVR RS-485 address (complies with the

DVR menu RS-485 ID).

Press E E N T E E R to confirm the setting or Esc to cancel.

RS485 Connected to

Port : _ [ 1 or 2 ]

RS485 Address:

_ _ _

DVR Type :

16Ch <

DVR type selection; select the type by channel number of the DVR.

Use the J J J O Y S S T I I I C K to adjust the selection.

Attention: For EDSR-400 DVR select "4ch-EDSR", not "4Ch"!

Press E E N T E E R to confirm the selection or E E S C to cancel.

DVR : 1__ changed

[ ENT ] to save

6.3.4 Camera List & Delete

This menu contains a list of all installed cameras as well as their settings. Furthermore, cameras can be deleted here.

M E E N U > DEVICE SETTING >

CAMERA LIST & DELETE > E E N T E E R

Total 005 Cameras

[ ENT ] to view list

After pressing the E E N T E E R key, the first camera is displayed.

Displays: RS-485: port number - RS485 address

DVR: DVR to which the camera is connected

CH: DVR video input

Press E E N

Press E

E

N

S

S

T

C

E E R to delete the camera.

C to return to camera list without deleting.

Use the

Press E E S S

J J J

C

O

C

Y S S T I I I C K for camera switching. to cancel .

Name RS485 DVR CH

012 2- 014 002 03 <

Delete Camera 012

[ ENT ] to delete.

18 EKB500_ma_en_rev1 5_3

6.3.5 Monitor List & Delete

This menu contains a list of all installed monitors as well as their settings. Furthermore, monitors can be deleted here.

M E E N U > DEVICE SETTING >

MONITOR LIST & DELETE > E E N T E E R

After pressing the E

E N T E

E R key, the first monitor is displayed.

Displays: Name: monitor number

DVR: DVR to which the monitor is connected.

CH: DVR monitor output

Total 005 Monitors

[ ENT ] to view list

Press

Press

E

E

E

E

N

N

T

T

E

E E

R

R

to delete the monitor.

R again to delete the monitor and return to monitor list.

Press E S S C to return to monitor list without deleting.

Use the J J J

Press E E S S C

O Y

S

S

T I I I C K

for monitor switching.

C to cancel.

Name DVR Mon

005 004 02 <

Del Monitor: 004

[ ENT ] to delete.

6.3.6 DVR List & Delete

This menu contains a list of all installed DVRs as well as their settings. Furthermore, DVRs can be deleted here.

M

E

E N U

> DEVICE SETTING >

DVR LIST & DELETE > E E N T E E R

Total 008 DVRs

[ ENT ] to view list

After pressing the E E N T E E R key, the first DVR is displayed.

Displays: Name:

RS-485:

DVR number port number - RS-485 address

Press

Press

E

E

E

E

N

N

T

T

E

E E to DVR list.

R

R

to delete the DVR.

R again to delete the DVR and return

Press E S S C to return to DVR list without deleting.

Use the J J J

Press E E S S C

O Y S S T I I I C K for DVR switching.

C to cancel.

Name RS485

004 1- 023 <

Del DVR : 004

[ ENT ] to delete.

19 EKB500_ma_en_rev1 5_3

6.3.7 Non-listed devices

This function is currently not supported by EKB-500.

Use this menu to approve / disapprove the control of devices not defined in the menu.

M E E N U > DEVICE SETTING > NON-LISTED-DEVICE > E E N T E E R

Allow Operation w/o

Keep the default setting “No Operation w/o list” at any time, as this function is reserved for future applications only. list [ ] to toggle

No Operation w/o list [ ] to toggle

6.4 KEYBOARD SETTING

This menu allows general keyboard and security settings.

6.4.1 Sub Keyboard Setting

This menu provides settings for multiple keyboard installations.

Keep the default value "0" for keyboard ID and number of sub keyboards for single keyboard installation.

For multiple keyboard installations, the keyboards should be assigned to different IDs.

Enter the keyboard ID 0~7 (one master keyboard with ID 0 required in system) and confirm with

E E N T T E E R .

.

.

If an ID for Subkeyboard (1~7) was entered, another menu page will open. Enter the total numbers of subkeyboards in the system.

Press E E N T E E R to confirm and exit.

This keyboard ID : 0

( 0 7 , 0 for master )

MAX Subkeyboards : 3

( 0 7 , 0 for master )

6.4.2 MENU Password

The setup menu access can be protected by password.

M E E N U > KEYBOARD SETTING > MENU PASSWORD > E E N T E E R

Enter a max. 8-character password.

Press E

E N T E

E R to confirm.

Repeat the password.

Press E E N T E R to confirm.

Input new Password :

_ _ _ _ _ _ _ _

Repeat Password :

_ _ _ _ _ _ _ _

For activating the password protection, use the

J J J O Y

S

S

T I I I C K and press

K to select "YES"

E E N T E E R R to confirm.

If password protection is activated, the setup menu access requires password entry.

Protect setup menu

NO < [ ] to change

Setup menu password set and enabled.

20 EKB500_ma_en_rev1 5_3

6.4.3 Lock password

If this password is activated, the keyboard will lock after 30 seconds with no keyboard operation.

Any key press after locking will display a password inquiry at the LCD display.

M E E N U > KEYBOARD SETTING > LOCK PASSWORD > E E N T E E R

Enter a max. 8-character password.

Press E

E N T E

E R to confirm.

Repeat the password.

Press E E N T E R to confirm.

Input new Password :

_ _ _ _ _ _ _ _

Repeat Password :

_ _ _ _ _ _ _ _

For activating the password protection, use the

J J J O Y

S

S

T I I I C K and press

K to select "YES"

E E N T E E R R to confirm.

Lock password is active.

Enable Lock Password

NO < [ ] to change

Lock password set and enabled.

6.4.4 Buzzer ON/OFF

M

E

E N U

> KEYBOARD SETTING > BUZZER ON/OFF > E

E N T

E

E R

Activate / deactivate buzzer.

Use the J J J O Y S S T I I I C K for selection and press E E N T E R to confirm.

Buzzer Enabled

[ ↑↓] to toggle

Buzzer Disabled

[ ↑↓] to toggle

6.4.5 Joystick calibration

M E E N U > KEYBOARD SETTING > JOYSTICK CALIBRATION >

Use this menu for joystick calibration.

E E N T T E E R

Keep the joystick in idle position and press the E E N T E E R key.

Release Joystick and press [ ENT ]

Move the J J J O Y S S T I I I C K towards all end stops including the third axis (left/right rotation).

For all X, Y, Z displays, the end stop message must be “OK".

Press E S S C to return to menu.

Move joystick to corners.

X+000 Y+000 Z+000

X-000 Y- OK Z-000

21 EKB500_ma_en_rev1 5_3

6.4.6 Keypad test

Use this menu for testing the keys’ functionality.

M

E

E N U

> KEYBOARD SETTING > KEYPAD TEST > E

E N T

E

E R

Press the keys to be checked.

If the keys work correctly, the LCD display shows the key function in clear text.

Press E S S C to return to menu.

[ _ _ _ _ _ _ _ _ _ ] Pressed

[ Esc ] to exit

6.4.7 Jog & Shuttle test

Use this menu for testing the jog/shuttle’s functionality.

M

E

E N U

> KEYBOARD SETTING > JOG&SHUTTLE TEST > E

E N T

E

E

R

R

Move the S S H U T T L L E E (outer ring) towards the left and right end stops. The display shows the 7 shuttle steps; reaching the end stop, the display shows >>>>7 (right end stop) resp. <<<<7 (left end stop).

Turn the J J J O G

to the left / right. If the the display counts from 0 to 9999.

J J J O G works correctly,

Press E S S C to return to menu.

Shuttle : >>>> 5

Jog : 9934

6.4.8 Load default setting

Use this menu to reset the keyboard to default setting.

M E E N U > KEYBOARD SETTING > LOAD DEFAULT SETTING> E E N T E E R

Press E E N T E E R to confirm the default setting loading. Load default setting

Press [ ENT ] to load..

A second security dialogue appears.

Enter the figures

Press E E S S C

1 1 , , , 2 2 , , , 3 3 and press E N T E E

C to cancel and return to menu.

R to confirm.

Input 123 to start

_ _ _ [ ENT ]

After confirmation, all settings are deleted and the keyboard is reset to default setting. A short buzzer blip confirms the reset.

6.4.9 Firmware update

This function allows the loading of new firmware upon availability. A PC with serial interface and an uncrossed RS-232 connection cable (pin 2, 3, 5 interconnected) is required.

M E E N U > KEYBOARD SETTING > FIRMWARE UPDATE> E E N T E E R

A second security dialogue appears.

Enter the figures

Press E E S S C

1 1 , , , 2 2 , , , 3 3 and press E N T E E

C to cancel and return to menu.

R to confirm.

Input 123 to start

_ _ _ [ ENT ]

22 EKB500_ma_en_rev1 5_3

7 OPERATION

7.1 NEW EKB-500 OPERATION CONCEPT (FROM FIRMWARE 1.5)

With firmware 1.5 the operation of keyboard will change.

Overview of the changes:

1. Main- , Call- and Matrix monitors are operated with same input procedures.

2. Cameras are operated with same input procedure for all types of monitors.

3. The keyboard detects automatically, if a camera has PTZ function or not and signalize PTZ devices with

"PTZ" in the LCD display.

4. The keyboard detects automatically, if a selected monitor is a DVR main monitor and signalizes selected main monitors with "DVR" in the LCD display. All DVR related functions such as playback, search, and multiview are active then.

5. Telemetry control will switch automatically with selecting a camera, also for main monitor operation.

6. The former "DVR-mode" with DVR key is cancelled. DVR key is inactive.

7.2 MONITOR SELECTION

To select a monitor for operation, press

> or

[ [ [ M O N I I I T O R N U M B E E R ] ] ] > M O N

> M O N > [ [ [ M O N I I I T O R N U M B E E R ] ] ] > E E N T E R

If the selected monitor is a DVR main monitor

(depending on monitor setup),the LCD display

will show ">DVR" in the upper right corner.

7.3 CAMERA SELECTION

To select a camera for operation, press

> or

[ [ [ C A M

E

E R A N U M B E

E R

] ] ]

>

C

A

M

> or

C A M > [ C A M E E R A N U M B E E R ] > E E N T E E R

> S S H I I I F F T (hold) > [ C A M E E R A N U M B E E R ]

If the selected camera is a PTZ camera

(depending on camera setup), the LCD display will show ">PTZ" in the upper right corner.

If a PTZ camera was selected together with a DVR main monitor, the display shows:

">DVR" and ">PTZ".

CAM - 001 MON - 01

___ [ CAM / MON ]

CAM - 001 MON - 04 > DVR

___ [ CAM / MON ]

CAM - 001 MON - 01

___ [ CAM / MON ]

CAM - 005 MON - 01 > PTZ

___ [ CAM / MON ]

CAM - 005 MON - 04 > DVR

___ [ CAM / MON ] >

23 EKB500_ma_en_rev1 5_3

7.4 DVR PASSWORD INPUT

If password protection is active in DVR, then the password is entered with the same procedure as described in ch. 7.3 CAMERA SELECTION:

> or

[ [ [ D V V R R N U M B E E R ] ] ] > D V R

> or

D V R > [ D V R N U M B E E R ] > E E N T E E R

> S S H I I I F F T (hold) > [ D V R N U M B E E R ]

7.5 DVR MAIN MONITOR OPERATION

If a DVR main monitor is selected, the LCD - Display will show "DVR" in upper right corner.

All DVR functions are active now as described below.

CAM - 001 MON - 01 > DVR

___ [ CAM / MON ]

EKB-500 provides a separate keypad for DVR control. The keys correspond to the EverFocus DVR front panel keys as regard to labelling and functionality.

Besides these keys, further keys like

M

E

E N U

or E

E N T E

E R are required for different functions.

NOTE: For browsing event list pages of DVR the movement). Moving the S S H U T T L L E E

S S H U T T L L E E ring switches with the first step (~20°

E to the limit may block browsing pages for ~1 second.

NOTE: If password protection is active at the DVR, please use password input.

D V R key (hold) + [ [ [ N U M B E E R ] ] ] key for

The range of functions varies, depending on the DVR model and firmware version.

24 EKB500_ma_en_rev1 5_3

The essential functions are described below; for further details please refer to the DVR manual.

Please note that this description doesn’t provide a full function description of the EverFocus DVRs.

Function Keys / operation

DVR setup menu

Full screen

Electronical zoom

Multiscreen display

Record

Playback

Playback search

Fast forward / reverse playback

Freeze image playback

Freeze image forward / reverse

Stop playback / recording

Main monitor status display

Sequence

Call & matrix monitor setting

Multiscreen setup

Video export

M E N U

Input channel number; key 1 is delayed for approx. 1 second to enable input of channels 10~16

Z O O M switches ON / OFF (in full screen mode)

M O D E switches between the available multiscreen displays

R E C starts the recording mode manually

P L A Y starts the playback mode without search

S E A R C H opens the search menu

S H U T T L E right (fast forward) resp. S H U T T L E left (fast reverse) in 7 steps, depending on shuttle speed

P A U S E freezes the image playback

J J O G left (reverse) resp. right (forward)

S T O P , first actuation stops the playback, second actuation stops the recording

D I I S P L A Y switches between the available status displays

S E Q starts the automatic switching mode

C A L L enters the setup menu for call and matrix monitors

Press S E L E C T to modify the individual camera screens within a multiscreen by entering the camera number

C O P Y opens the image export menu

25 EKB500_ma_en_rev1 5_3

7.6 PTZ OPERATION / SETUP

The operation of speed domes and telemetry receivers requires the setup of these devices in the EKB 500 menu. Settings within the following menus have to be adjusted:

M E

E

E

M E

N

N

U

U

> COM PORT SETTING for interface and protocol type setting

> DEVICE SETTING > CAMERA SETTING for speed dome / telemetry receiver connection settings

EKB 500 is optimised for EverFocus EPTZ series speed dome control. Furthermore, basic functions of other supported speed dome types can be operated.

The following operating elements are available for camera control:

General key description:

I I

Z

T

I

Z

R

R I I

F F O

O

I

A

S S

O

C K

+

O C C U

M

A

/ / /

I I I N

U

/

T O / / / H O L

U S S F F .

.

-

.

:

/

:

/

:

/

/ / N

O

.

.

.

U

: : :

T :

L D : : : reserved for future applications manual iris control, + opens iris, - closes iris manual focus, F. TELE; N. WIDE

Zoom keys, same function as joystick rotation, IN = TELE, OUT = WIDE start and save positions P

S

S

P

T

A .

.

.

P P A N

S

S E

O

O

T

E

S

S

U

O

T

I I I

P

R

T

N

P

I I I O

:

:

:

:

N

:

S

H O M E E :

S H

I I I

F

F T

: start and save preset tours autopan, start and save automatic pan operation function key for programming termination switch key for second key level (depending on function) start and save home position switch key for second key level (depending on function)

26 EKB500_ma_en_rev1 5_3

7.6.1 EverFocus EPTZ series

The following functions are available after camera selection in CAM-MON mode:

EPTZ dome operation outline

Function Keys / operation

Open dome menu

Switch menu functions

Change menu settings

Leave dome menu

Pan – Tilt

Zoom TELE / WIDE

Focus

Iris +/-

Start position (preset)

Save position (preset)

Preset parameters

Delete preset

Tour mode 1 (one way)

Tour mode 2 (back and forth)

Setup tour

CAM : 0001 MON : 0001

[ CAM / MON / DVR ]

M E E N U or C A M (hold) + M E E N U (if Main monitor is selected)

J J J O Y S S T I I I C K K

J J J O Y S S T I I I C K K

C L L R (hold) + M E E N U or menu item EXIT > E E N T E R

J J J O Y S S T I I I C K K

TELE:

WIDE:

Z

Z

Z Z

O

O

O

O

M

M

I I I N

O

or

U T

J J J

or J

O

J J

Y

O

S

S

Y

T

S S

I I I

T

C

I I I

K

C C

rotation to the right

K K rotation to the left

TELE: F F O C U S S F F .

.

.

; WIDE: F F O C U S S N .

.

.

Open iris: I I I R I I I S S + / close iris: I I I R I I I S S .

.

.

Preset number + P P O S S I I I T I I I O N / P P O S S I I I T I I I O N + preset number > E E N T E R

S S H I I I F F T (hold) + P P O S S I I I T I I I O N > preset number > E E N T E E R

S S E E T (hold) + P P O S S I I I T I I I O N

C L L R (hold) + P P O S S I I I T T I I I O N

T O U R > number > E E N T E E R

S S H I I I F F T (hold)+ T O U R > number > E E N T E E R R

Start autopan

360° autopan

Setup autopan

Start home position

Setup home position

Alarm – preset link

Delete alarm – preset link

S

S

E

E T

(hold) +

T O U R

A .

.

.

P P A N > speed 1 1 ~ 2 2 3 3 9 9 > E E N T E R

S

S H

I I I

F

F T

(hold) + A

A

.

.

.

P

P A N

> speed 1

1 ~

2

2

3

3

9

9

> E N T E

E R

S S E E T (hold) + A .

.

.

P P A N , E E N T E E R start / end

H O M E E

S S E E T (hold) + H O M E E , enter position and time definition

F 1 1 , enter alarm contact / preset definition

C L L R (hold)+ F F 1 1 > alarm 1 1 ~ 4 4 > E E N T E E R

27 EKB500_ma_en_rev1 5_3

7.6.1.1 EPTZ on-screen display

Start EPTZ menu: If DVR Main monitor is selected ("DVR" in LCD - display):

C A M (hold) + M E E N U

If no DVR Main monitor is selected:

M E E N U or C C A M (hold) + M E E

Switch between the settings: settings:

Leave the menu:

J

J

J

J

J

J

O

O

Y

Y

S

S

S

S

T

T

I

I

I

I

I

I

C

C

K

K

Menu item EXIT >

C L L R (hold) + M E E N

E E

U

N T E R or

N U

7.6.1.2 Positions (presets)

Save presets

S S H I I I F F T (hold) + P P O S S I I I T I I I O N

> enter preset number > E E N T E E R

Define preset parameters

S S E E T (hold) + P P O S S I I I T I I I O N

> enter preset number > E E N T E E R

Enter the preset dwell time within preset-tours from 1~239 seconds

> E E N T E E R

Preset travel speed from 1 ~ 239 seconds

> E E N T E E R

Enter a preset name (up to 20 characters)

J J J O Y S S T I I I C K changes the characters

Enter switches to next character

C L L R R deletes the current character

Delete preset

C L L R R (hold) + P P O S S I I I T I I I O N

> enter preset number > E E N T E E R

Camera:0001 Save to

Position:___[1-192]

Set Camera:0001

Position:___[1-192]

Set Position:001

Dwell:___[1-239]

Set Position:001

Speed:___[1-239]

Title for position

_________________

V

__________________

Camera:0001

Del Position:___

28 EKB500_ma_en_rev1 5_3

Start preset

P P O S S I I I T I I I O N > enter preset number > E E N T E R

Camera:0001 go to

Position:___[1-192]

7.6.1.3 Home position

The home position is the position (preset) which is approached after a pre-defined duration upon last speed dome operation.

S S E E T (hold) + H O M E E

> enter inactivity duration 1 ~ 999 minutes

Back to home if no action for ___Minute

> Enter

Use the

> E E N T E E

J

R

J

R

J O Y S S T I I I C K to approach the requested position

Use the J J J O Y S S T I I I C K to activate the HOME function.

[

Move to home position

[ENT] to confirm

Auto Back Enabled

↑↓] to toggle

7.6.1.4 Autopan

End / stop definition:

S E E T (hold) + A .

.

.

P P A N

Use the joystick to approach the requested position A, enter the dwell time at this end stop in seconds

( 1

1 ~

2

2

3

3

9

9

) > E

E N T E

E R

Use the J J J O Y S S T I I I C K to approach the requested position B, enter the dwell time at this end stop in seconds

( 1

1 ~

2

2

3

3

9

9

) > E

E N T E

E R

Activate A-B autopan

A .

>

.

.

P P

E E

A

N

N

T

> enter pan speed

E E R

1 1 ~ 2 2 3 3 9 9

Activate 360° autopan

A continuous 360° pan operation is also possible.

S S H I I I F F T (hold) + A .

.

.

> enter pan speed

P P

1 1

A

~

N

2 2 3 3 9 9 > E E N T E E R

Position A

Dwell:___[1-239]

Move to Position B

[ENT] to confirm

Position B

Dwell:___[1-239]

Speed:___[1-239]

[ENT] to start.

Speed:___[1-239]

[ENT] to start.

29 EKB500_ma_en_rev1 5_3

7.6.1.5 Preset tours

The EPTZ series supports up to 16 programmable preset tours with up to 16 presets each.

For these tours, 2 operation modes are available:

1) Mode 1 (One way): after approaching all programmed presets, the tour restarts at the first programmed preset.

Example: 1-2-3-4-5-6 > 1-2-3-4-5-6 > 1-2-3-4-5-....

2) Mode 2 (back and forth) > after approaching all programmed presets, the speed dome returns to the presets in reverse order.

Example: 1-2-3-4-5-6 > 5-4-3-2-1 > 2-3-4-5-6 > 5-.....

Preset tour programming

S S H I I I F F T (hold) + T O U R

> enter tour number 1 1 1 ~ 1 1 6 > E E N T E R

Enter the presets in correct order (max. 16) .

Press E E N T E E

Press S S T O

E R

P P

R to save and add further preset tours.

to finish preset tour programming.

Set Camera:0001

Tour:__[1-16]

Add Position#01:___

[ENT / STOP]

Tour:001 Pos#01:001<

[ENT] to save

Activation preset tour mode 1 (One way)

T O U R

> enter tour number > E

E N T

E

E R

Activation preset tour mode 2 (back and forth)

S S H I I I F F T (hold) + T O U R > enter tour number > E E N T E E R

Camera:0001

Run Tour:__[1-16]

Camera:0001

Run Tour:__[1-16]

30 EKB500_ma_en_rev1 5_3

7.6.1.6 Alarm contact settings

This function allows the EPTZ dome alarm contact assignment to presets or preset tours.

Program alarm / preset / tour link

F 1 1 > enter alarm contact number 1 ~ 4 Link Alarm:_ [1-4] to

Position [ ↑↓]:___

Use the J J J O Y S S T I I I C K to switch between preset

(position) and preset tour (tour)

Delete alarm / preset / tour link

C L

>

L R

E

R

E

+

N T E

F

E

F 1

R

> enter alarm contact number 1 1 ~ 4

Link Alarm:_ [1-4] to

Tour [ ↑↓]:___

Del AlarmLink:_[1-4]

[ENT] to confirm

31 EKB500_ma_en_rev1 5_3

7.6.2 EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 operation

Required protocol type in "COM PORT SETTINGS": A-TYPE / SAMSUNG

7.6.2.1 On-screen display

Start menu:

Switch between the settings:

If DVR Main monitor is selected ("DVR" in LCD - display):

C A M (hold) + M E E N U

If no DVR Main monitor is selected:

M E E N U or C C A M (hold) + M E E N U

J

J

J

J

J

J

O

O

Y

Y

S

S

S

S

T

T

I

I

I

I

I

I

C

C

K

K

K

C L L R (hold) + M E E N U Leave the menu:

7.6.2.2 Presets

Preset parameters are defined in the dome menu. Please refer to the manual of the respective model.

Save presets

S

S H

I I I

F

F T

(hold) + P

P O

S

S

I I I T

I I I O N

> enter preset number > E E N T E E R

Delete preset

Camera:0001 Save to

Position:___[1-192]

Camera:0001

C L L R R (hold) + P P O S S I I I T I I I O N

> enter preset number > E

E N T E R

Start preset

P P O S S I I I T I I I O N > enter preset number > E E N T E R

Del Position:___

Camera:0001 go to

Position:___[1-192]

7.6.2.3 Home position

The home position is the position (preset) which is approached after a pre-defined duration upon last speed dome operation.

Define the home position within the speed dome’s on-screen display. For further details, please refer to the manual of the respective model.

The manual home position start is effected by starting the preset programmed for this function in the dome menu.

The H O M E E key is inactive with this protocol.

32 EKB500_ma_en_rev1 5_3

7.6.2.4 Autopan

End stop definition

Define both the end stops and the autopan speed in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model.

Start A-B autopan

A

.

.

.

P

P A N

> enter pan speed 1 ~

2

2

3

3

9

9

(any input, value is irrelevant due to speed being defined in the dome menu) > E E N T E E R

Speed:___[1-239]

[ENT] to start.

7.6.2.5 Preset tour / Pattern

Define patterns (stored motion sequences of 30 seconds each) in the speed dome’s on-screen display.

For further details, please refer to the manual of the respective model.

Activate pattern

T O U R > enter pattern number 1~3 > E E N T E E R

Camera:0001

Run Tour:__[1-16]

Activate Preset Tour

T O U R > 0 > E E N T E E R

7.6.3 Pelco-D / -P protocol compatible devices’ operation

Required protocol type in "COM PORT SETTINGS": Pelco-D / Pelco-P (according to dome / receiver)

Implemented protocol is based and tested with Spectra IIITM series halfduplex RS-485.

Third party domes with implemented Pelco-D protocol may have different features and

ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1 at the keyboard, i.e. the address assigned to the dome / receiver in the EKB 500 menu must be 1 below the address set in the dome / receiver itself!

7.6.3.1 On-screen display

Start menu:

Switch between the settings: settings:

Leave the menu: or

S

I I

E

M

E

E N U

S

I

E

H

R

X

I I

I

P

I

I

I

I

I

P

I

S

F

S

T

R

F

E E

T

+

S S E E T > 9 9 5

(hold) +

+

5

J

>

J J O

E

Y

E

S S

N T

T I

T

I I

E E

C

R

K entry in OSD menu, confirm with I I I R I I I S S + alternative:

For exit of some sub-menus the key I I I R I I I S S

M E E N

P

N

S or P

P

is used.

R

U

E

E

S

S

E

E T

> 9

9

5

5

> E

E N

T

T

E

E

R

33 EKB500_ma_en_rev1 5_3

7.6.3.2 Presets

Save presets

S S H I I I F F T (hold) + P P O S S I I I T I I I O N

> enter preset number > E E N T E E R

Delete preset

C

L

L

R

R

(hold) + P

P O

S

S

I I I T

I I I O N

> enter preset number > E E N T E E R

Start preset

P P O S S I I I T I I I O N > enter preset number > E E N T E R

Camera:0001 Save to

Position:___[1-192]

Camera:0001

Del Position:___

Camera:0001 go to

Position:___[1-192]

7.6.3.3 Autopan

End stop definition

Define both the end stops and the autopan speed in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model.

Start A-B Autopan

A

.

.

.

P

P A N

> enter pan speed 1 ~

2

2

3

3

9

9

(any input, value is irrelevant due to speed being defined in the dome menu)

Speed:___[1-239]

[ENT] to start.

> E E N T E E R

ATTENTION: At some third party domes with implemented Pelco-D the Autopan starts with alternative command:

P P O S S I I I T I I I O N > 9 9 9 9 > E E N T E R

7.6.3.4 Frame Scan / Preset tour

Frame scan is a modified Autopan mode, the Autopan stops at defined positions for a programmed time.

Settings for this are defined in the speed dome OSD manual. At some third party domes with implemented Pelco-D protocol this command starts Preset tour.

Start Framescan

P P O S S I I I T I I I O N > 9 9 8 8 > E E N T E R

34 EKB500_ma_en_rev1 5_3

7.6.3.5 Pattern / Preset Tour

Define patterns, which also can contain a preset tour, in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model.

Activate pattern

T O U R > enter pattern number > E E N T E E R R

Camera:0001

Run Tour:__[1-16]

ATTENTION: At some third party domes with implemented Pelco-D the Preset tour starts with alternative command:

P P O S S I I I T I I I O N > 9 9 8 8 > E E N T E R

7.6.4 LG protocol compatible devices’ operation

EKB 500 supports the following functions for boxed type autofocus cameras with LG RS-485 protocol:

Focus near/far

>

OSD menu ON/OFF

Navigation in OSD - menu

IR cut filter OFF (night mode)

IR cut filter Auto

IR cut filter ON (day mode)

>

>

>

>

>

>

F

Z

P

P

P

F

M

Z

P

P

P

O

E E

O

O

O

O

S

S

S

C

N

O

S

S

S

I

I

I

I

I

I

I

I

I

U S

U

M

T

T

T

S

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

N

N

N

O

O

O

.

.

/ >

.

/ >

/ >

N

N

N

>

>

>

Z

Z

Z

Z

8

8

9

8

9

8

9

0

O

F

8

9

0

F

O

O

O

O

>

>

>

M

C C

M

E

E

E

E

E

U

O

S

O

N

N

N

U

T

T

T

F

U

E

E

T or turn J J J O Y S S T I I I C K left / right

F

T

E

E

.

.

T

.

R

R

R

/ / / F

R

T E E

R

R

F O C U S S N .

.

.

/ > F F O C U S S F .

.

.

Set Camera ID (RS-485 address) > F F 1 1 > [ [ [ N U M B E E R ] ] ] > E E N T E E R

Set Camera New Addr:

___[0-255]

7.6.5 Panasonic protocol compatible devices’ operation

EKB 500 supports the following functions for cameras with Panasonic RS-485 protocol.

Limitations for special camera functions are possible.

Please consult the speed dome user manual for usage of special keys such as F1 ~ F4.

Fixed values for communication settings: Wait time:

Delay time:

Interface:

Alarm data:

OFF

OFF

No parity, 8 data bit, 1 stop bit

POLLING

35 EKB500_ma_en_rev1 5_3

8 SPECIFICATIONS

Keys 48

Joystick 3-axis

Display 2 lines with 20 characters each

RS-485

RS-232

RS-485 protocols

2 independent RS-485 ports with 2 RJ-45 sockets each

1 x RS-232, Sub-D9 socket (service)

EverFocus, ED2200/2250, Samsung Electr., Pelco-D,

Pelco-P

Power source

Power consumption

Ambient temperature

Dimensions

LG, Panasonic

12 VDC +-10%, via power supply 110/230 VAC

10 W max.

0°C ~ 40°C, non-condensing

360 (W) x 110 (H) x 200 (D) mm

36 EKB500_ma_en_rev1 5_3

9 APPENDIX A: FACTORY SETTINGS

PORT settings:

Port 1: 9600 baud, EverFocus

Port 2: 9600 baud, EverFocus

DEVICE SETTINGS / DVR

DVR1: 16Ch., port 1 Addr.1

DVR2: 16Ch., port 1 Addr.2

DVR3: 16Ch., port 1 Addr.3

DVR4: 16Ch., port 1 Addr.4

DVR5: 16Ch., port 1 Addr.5

DVR6: 16Ch., port 1 Addr.6

DEVICE SETTINGS / MONITOR

Mon1: connected to DVR1, MAIN monitor

Mon2: connected to DVR1, CALL monitor

Mon3: connected to DVR1, Matrix 1

Mon4: connected to DVR1, Matrix 2 (M2)

Mon5: connected to DVR1, Matrix 3 (M3)

Mon6: connected to DVR1, Matrix 4 (M4)

Mon7: connected to DVR2, MAIN monitor

Mon8: connected to DVR3, MAIN monitor

Mon9: connected to DVR4, MAIN monitor

Mon10: connected to DVR5, MAIN monitor

Mon11: connected to DVR6, MAIN monitor

......

DEVICE SETTINGS / CAMERA

Cam1: connected to DVR1, input1, PTZ-ID: 1, Port 1

Cam2: connected to DVR1, input2, PTZ-ID: OFF

Cam3: connected to DVR1, input3, PTZ-ID: OFF

.......

Cam16: connected to DVR1, input16, PTZ-ID: OFF

Cam17: connected to DVR2, input1, PTZ-ID: OFF

.......

Cam32: connected to DVR2, input16, PTZ-ID: OFF

Cam33: connected to DVR3, input1, PTZ-ID: OFF

.......

Cam48: connected to DVR3, input16, PTZ-ID: OFF

37 EKB500_ma_en_rev1 5_3

Cam49: connected to DVR4, input1, PTZ-ID: OFF

.......

Cam64: connected to DVR4, input16, PTZ-ID: OFF

Cam65: connected to DVR5, input1, PTZ-ID: OFF

.......

Cam80: connected to DVR5, input16, PTZ-ID: OFF

Cam81: connected to DVR6, input1, PTZ-ID: OFF

.......

Cam96: connected to DVR6, input16, PTZ-ID: OFF

PASSWORDS: disabled

BUZZER: ON

38 EKB500_ma_en_rev1 5_3

EverFocus Electronics Corp.

Head Office:

12F, No.79 Sec. 1 Shin-Tai Wu Road,

Hsi-Chih, Taipei, Taiwan www.everfocus.com.tw

USA Office:

1801 Highland Ave. Unit A

Duarte, CA 91010, U.S.A. www.everfocus.com

European Office:

Albert-Einstein-Straße 1

D-46446 Emmerich am Rhein, Germany www.everfocus.de

China Office:

Room 609, Technology Trade Building,

Shandgdi Information Industry Base,

Haidian District, Beijing,China www.everfocus.com.cn

Japan Office:

1809 WBG MARIBU East 18F,

2-6 Nakase.Mihama-ku.

Chiba city 261-7118, Japan www.everfocus.com

39 EKB500_ma_en_rev1 5_3

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents