MBE Family (LAN RANger Series)
Ethernet Remote Access Routers (MBE10-1, MBE10-8,
MBE10-1D, MBE10-8D)
Version 7
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by
RAD Data Communications.
Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the MBE Family (LAN
RANger Series) and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD.
MBE Family (LAN RANger Series) is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark.
You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the MBE
Family (LAN RANger Series). You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the
MBE Family (LAN RANger Series), based on or derived in any way from the MBE Family (LAN RANger
Series). Your undertaking in this paragraph shall survive the termination of this Agreement.
This Agreement is effective upon your opening of the MBE Family (LAN RANger Series) package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the MBE Family (LAN
RANger Series) and all copies and portions thereof.
For further information contact RAD at the address below or contact your local distributor.
International Headquarters
RAD Data Communications Ltd.
24 Raoul Wallenberg St.
Tel Aviv 69719 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
E-mail: [email protected]
U.S. Headquarters
RAD Data Communications Inc.
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100, Toll free: 1-800-444-7234
Fax: (201) 529-5777
E-mail: [email protected]
© 1994-2003 RAD Data Communications Ltd. Publication No. 572-200-02/03
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Order from: Cutter Networks
Limited Warranty
RAD warrants to DISTRIBUTOR that the hardware in the MBE Family (LAN RANger Series) to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR.
If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the appropriate corrective action: a) supply a replacement part, or b) request return of equipment to its plant for repair, or c) perform necessary repair at the equipment's location.
In the event that RAD requests the return of equipment, each party shall pay one-way shipping costs.
RAD shall be released from all obligations under its warranty in the event that the equipment has been subjected to misuse, neglect, accident or improper installation, or if repairs or modifications were made by persons other than RAD's own authorized service personnel, unless such repairs by others were made with the written consent of RAD.
The above warranty is in lieu of all other warranties, expressed or implied. There are no warranties which extend beyond the face hereof, including, but not limited to, warranties of merchantability and fitness for a particular purpose, and in no event shall RAD be liable for consequential damages.
RAD shall not be liable to any person for any special or indirect damages, including, but not limited to, lost profits from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, repair, maintenance or use of the MBE Family (LAN RANger Series), and in no event shall RAD's liability exceed the purchase price of the MBE Family (LAN RANger Series).
DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makes relating to MBE Family (LAN RANger Series) and for ensuring that replacements and other adjustments required in connection with the said warranties are satisfactory.
Software components in the MBE Family (LAN RANger Series) are provided "as is" and without warranty of any kind. RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose. RAD shall not be liable for any loss of use, interruption of business or indirect, special, incidental or consequential damages of any kind. In spite of the above RAD shall do its best to provide error-free software products and shall offer free Software updates during the warranty period under this Agreement.
RAD's cumulative liability to you or any other party for any loss or damages resulting from any claims, demands, or actions arising out of or relating to this Agreement and the MBE Family (LAN RANger Series) shall not exceed the sum paid to RAD for the purchase of the MBE Family (LAN RANger Series). In no event shall RAD be liable for any indirect, incidental, consequential, special, or exemplary damages or lost profits, even if RAD has been advised of the possibility of such damages.
This Agreement shall be construed and governed in accordance with the laws of the State of Israel.
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
General Safety Instructions
The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual.
Safety Symbols
Warning
This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel.
Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines.
.
Protective earth: the marked lug or terminal should be connected to the building protective earth bus.
Warning
Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached.
Please observe the following precautions:
•
Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter.
•
Do not attempt to adjust the laser drive current.
•
Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam.
•
The use of optical devices with the equipment will increase eye hazard.
•
Use of controls, adjustments or performing procedures other than those specified herein, may result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!
Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Order from: Cutter Networks
Handling Energized Products
General Safety Practices
Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist.
Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts.
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets.
Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground.
Connection of AC Mains
Make sure that the electrical installation complies with local codes.
Always connect the AC plug to a wall socket with a protective ground.
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A.
Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation.
Connection of DC Mains
Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded.
Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards.
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel.
Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes.
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A.
Before connecting the DC supply wires, ensure that power is removed form the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position.
A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation.
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Order from: Cutter Networks
Connection of Data and Telecommunications Cables
Data and telecommunication interfaces are classified according to their safety status.
The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manual.
V.11, V.28, V.35, V.36, RS-530,
X.21, 10 BaseT, 100 BaseT,
Unbalanced E1, E2, E3, STM, DS-2,
DS-3, S-Interface ISDN, Analog voice
E&M xDSL (without feeding voltage),
Balanced E1, T1, Sub E1/T1
SELV Safety Extra Low Voltage:
Ports which do not present a safety hazard. Usually up to 30 VAC or 60 VDC.
TNV-1 Telecommunication Network Voltage-1:
Ports whose normal operating voltage is within the limits of SELV, on which overvoltages from telecommunications networks are possible.
FXS (Foreign Exchange Subscriber) TNV-2 Telecommunication Network Voltage-2:
Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are not possible. These ports are not permitted to be directly connected to external telephone and data lines.
FXO (Foreign Exchange Office), xDSL
(with feeding voltage), U-Interface
ISDN
TNV-3 Telecommunication Network Voltage-3:
Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are possible.
Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a qualified safety engineer.
Always make sure that the equipment is grounded before connecting telecommunication cables. Do not disconnect the ground connection before disconnecting all telecommunications cables.
Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables.
Extra caution should be exercised during thunderstorms.
When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connections should comply with the local codes.
The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines. In order to reduce the risk, there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors.
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Caution
Attention
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords.
Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure.
Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions.
Do not attempt to tamper with any carrier-provided equipment or connection hardware.
Electromagnetic Compatibility (EMC)
The equipment is designed and approved to comply with the electromagnetic regulations of major regulatory bodies. The following instructions may enhance the performance of the equipment and will provide better protection against excessive emission and better immunity against disturbances.
A good earth connection is essential. When installing the equipment in a rack, make sure to remove all traces of paint from the mounting points. Use suitable lock-washers and torque. If an external grounding lug is provided, connect it to the earth bus using braided wire as short as possible.
The equipment is designed to comply with EMC requirements when connecting it with unshielded twisted pair (UTP) cables. However, the use of shielded wires is always recommended, especially for high-rate data. In some cases, when unshielded wires are used, ferrite cores should be installed on certain cables. In such cases, special instructions are provided in the manual.
Disconnect all wires which are not in permanent use, such as cables used for one-time configuration.
The compliance of the equipment with the regulations for conducted emission on the data lines is dependent on the cable quality. The emission is tested for UTP with 80 dB longitudinal conversion loss
(LCL).
Unless otherwise specified or described in the manual, TNV-1 and TNV-3 ports provide secondary protection against surges on the data lines. Primary protectors should be provided in the building installation.
The equipment is designed to provide adequate protection against electro-static discharge (ESD).
However, it is good working practice to use caution when connecting cables terminated with plastic connectors (without a grounded metal hood, such as flat cables) to sensitive data lines. Before connecting such cables, discharge yourself by touching earth ground or wear an ESD preventive wrist strap.
FCC-15 User Information
This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the Installation and Operation manual, may cause harmful interference to the radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Canadian Emission Requirements
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing
Equipment Regulation.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Warning per EN 55022 (CISPR-22)
Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user will be required to take adequate measures.
Avertissement
Cet appareil est un appareil de Classe A. Dans un environnement résidentiel, cet appareil peut provoquer des brouillages radioélectriques. Dans ces cas, il peut
être demandé à l’utilisateur de prendre les mesures appropriées.
Achtung
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkströrungen auftreten, in welchen Fällen der
Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Order from: Cutter Networks
Manufacturer's Name:
Declaration of Conformity
RAD Data Communications Ltd.
Manufacturer's Address:
24 Raoul Wallenberg St.
Tel Aviv 69719
Israel declares that the product:
Product Name:
MBE10-1, MBE10-8, MBE10-1D, MBE10-8D conforms to the following standard(s) or other normative document(s):
EMC
: EN 55022 (1994) Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
EN 50082-1 (1992) Electromagnetic compatibility - Generic immunity standards for residential, commercial and light industry.
Safety:
EN 60950 (1992/93) Safety of information technology equipment, including electrical business equipment.
Supplementary Information:
The product herewith complies with the requirements of the EMC Directive 89/336/EEC and the Low
Voltage Directive 73/23/EEC. The product was tested in a typical configuration.
Tel Aviv, September 18 th , 1996
Haim
Quality
European Contact:
RAD Data Communications GmbH, Otto-Hahn-Str. 28-30, 85521
Ottobrunn-Riemerling, Germany
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Conventions
Note
Caution
A note draws attention to a general rule for a procedure, or to exceptions to a rule.
A caution warns of possible damage to the equipment if a procedure is not followed correctly.
Warning
A warning alerts to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the equipment. If these instructions are not followed exactly, possible bodily injury may occur.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Contents
Chapter 1. Introduction
1.1
1.2
1.3
1.4
Chapter 2. Installation
2.1
2.2
2.3
2.4
2.5
Chapter 3. Operation
3.1
3.2
Chapter 4. Troubleshooting and Diagnostics
4.1
4.2
Appendix A. Pin Assignment
MBE Family
Installation and Operation Manual
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 i www.bestdatasource.com
Table of Contents
List of Figures
1-2. MBE16-8 Filtering and Forwarding in Bridge Mode ...............................................................
List of Tables
1-1. Bridge Mode Product Intercompatibility ................................................................................
ii
Order from: Cutter Networks
MBE Family
Installation and Operation Manual
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Note
Chapter 1
Introduction
This chapter:
•
Provides a general overview of versions of MBE units, features, and ordering options
• Provides a physical description of MBE
•
Describes the general functionality of MBE
•
Lists technical specifications.
This manual is supplemented by the LAN RANger Series Configuration Guide. The term MBE refers to MBE10-1, MBE10-8, MBE10-1D, and
MBE10-8D throughout this manual.
1.1 Overview
General
Versions
The MBE family of Ethernet Remote Access Routers allows the connection of remote LANs or single workstations to a central LAN over a wide variety of WAN interfaces and services. Connection may be made via ISDN, Frame Relay, leased or dialup lines.
IP routing is supported over PPP, SLIP, CSLIP or Frame Relay (RFC 1490). IPX can be routed over PPP or Frame Relay (RFC 1490). Bridge mode is available if the
MBE family device operates opposite another MBE family device.
Four standalone models are available:
•
MBE10-1
is a single WAN port router/bridge. As a bridge, it allows remote connection of a single workstation to a central LAN. As a router, it enables connection of a remote Ethernet LAN.
•
MBE10-8
is a single WAN port router/bridge. As a bridge, it allows connection of a remote Ethernet (consisting of up to 80 workstations) to a central Ethernet
LAN. As a router, it allows connection of a remote Ethernet LAN.
•
MBE10-1D
is a dual WAN port router/bridge. As a bridge, it allows connection of two single remote workstations (one on each link) to a central LAN. As a router, it allows connection of a remote Ethernet LAN.
Order from: Cutter Networks
Overview 1-1 www.bestdatasource.com
Ph:727-398-5252/Fax:727-397-9610
Chapter 1 Introduction
MBE Family
Installation and Operation Manual
Applications
MBE can be used in a wide range of applications, employing diverse communication links and LAN equipment. For more details on typical MBE applications, see the
LAN RANger Series Configuration Guide .
Features
•
MBE10-8D
is a dual WAN-port router/bridge, As a bridge, it allows connection of two remote Ethernet LANs, each consisting of up to 80 workstations to a central Ethernet LAN. As a router, it allows connection of a remote Ethernet
LAN.
The MBE serial link interface options are: V.35, V.24/RS-232, V.36/RS-422, X.21,
RS-530, 4W, ISDN and CSU/DSU.
Routing and Bridging Support
The MBE Family supports remote access routing and bridging for connecting remote PCs or LANs to a central LAN over a wide variety of WAN interfaces and services. This includes ISDN, Frame Relay, Leased Line, dial-up modems, and
DDS.
Routing and bridging are performed on a link-by-link basis. There are no bridging or routing limitations on the central LAN. However, additional bridges should not be connected to the remote LAN.
•
Router links can operate opposite any PPP standard compliant device, including third party routers and software-based PPP dialers, such as
Windows 95.
• Bridge links are transparent to Layer 3 protocols, such as NetBIOS and
DECNET.
A backup link may be defined, which will be automatically activated if a failure occurs on the main link.
Management
Setup and configuration can be carried out from an ASCII terminal or PC terminal emulator connected to the control port, from any SNMP management station, such as RADview, or through TELNET (see the
LAN RANger Series Configuration
Guide
).
IP/IPX Support
Internet Protocol (IP) specifies support or MTU (Maximum Transmission Unit) fragmentation and reassembly of packets to form datagrams. The MTU defines the limit on fragment size transmitted on a physical network. The local terminal must support the reassembly of IP packets in order to read the IP datagram.
MBE supports networks that have multiple IP nets on the LAN.
1-2 Overview
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 1 Introduction
The Single IP address translation feature permits a small or medium office LAN to connect to the Internet or Intranet transparently. Single IP uses a single, dynamically or statically allocated IP address for all users on the LAN.
•
IP can be routed over PPP, SLIP, CSLIP or Frame Relay.
•
IPX can be routed over either PPP or Frame Relay.
Quick Setup
The Quick Setup menu enables the adjustment of setup and link configuration parameters while MBE is operating. For a complete description of the Quick Setup menu, see the
LAN RANger Series Configuration Guide
.
Transparent Remote-to-Remote Forwarding
Transparent remote-to-remote forwarding enables direct data transfer between two remote sites, whether or not the links are bridges or routers.
Security
Unauthorized entry to an office LAN is prevented by an Integral Solid Firewall using session-based firewalls. When enabled, access to the LAN is restricted to only applications enabled via the Firewall Forward Application List. In addition, access to the MBE unit can be blocked or password-protected through TELNET or SNMP.
MBE uses PAP/CHAP security for applications that include router links. PAP/CHAP and a scripting tool provide Internet Access authentication.
Dialback over PPP to a station using a router link at a fixed location is supported in
Microsoft operating environments (such as Windows 95). This feature adds security by verifying the user's identity and location. It also reduces costs to mobile users.
MBE also supports Remote Dial-In User Service (RADIUS), which is a client/server security protocol. Security information is stored in a RADIUS server. MBE communicates with the RADIUS server to authenticate users.
WAN Economy
Connection on Demand (COD) enables links to be connected or disconnected according to time, traffic or management. COD may be triggered based on userdefined masks.
Spoofing is used to reduce WAN link up-time and traffic by increasing the period between RIP, SAP or IPX Keep Alive broadcasts.
Filters based on user-defined masks improve WAN utilization by ensuring that only necessary packets are transmitted over the WAN. A special hardware filtering technique is used to ensure high performance and easy installation.
ISDN Support
MBE supports applications operating over ISDN networks. ISDN software may be downloaded into flash memory via TELNET or SNMP.
A bandwidth threshold may be set in order to control the amount of traffic passing through ISDN lines. The first ISDN line operates according to the COD
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Overview 1-3 www.bestdatasource.com
Chapter 1 Introduction
MBE Family
Installation and Operation Manual configuration. If traffic exceeds the defined threshold, the second ISDN line will be connected.
Dual Image Flash Memory
Two different versions of software may be saved in two different partitions. At reset, MBE automatically runs the software stored in the primary partition. New software versions are stored in the secondary partition. If the software download is successful, the secondary partition becomes primary, and MBE resets, automatically running the new software version. If the download is not successful, the previous software version will continue to run.
1.2 Physical Description
shows the 3-D view of an MBE product.
Figure 1-1. MBE Product 3-D View
Front Panel
The front panel includes LEDs indicating operational and traffic status, a Control interface for connection to a management terminal, and a Reset button for resetting the device (see Chapter 3,
Operation
).
Rear Panel
The rear panel contains a socket for connection to a 100–240 V, 50/60 Hz power source. It also includes LINK interfaces for connecting MBE to a communication
1-4 Physical
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 1 Introduction link. In addition, it has a LAN interface for connection to the Ethernet LAN (see
Interfaces and Connections
in
Chapter 2
).
1.3 Functional Description
General
Routing Mode
For a description of the IP/IPX routing, see the
LAN RANger Series Configuration
Guide
.
Bridge Mode
In bridge mode, MBE units operate in pairs. Each MBE must be configured for its specific application, as the local and remote units differ in their functions. See
for an illustration of MBE filtering and forwarding. MBE operation is automatic, including serial link startup and recovery, and learning of address tables.
Central LAN
Ethernet
802.3
Frames
Order from: Cutter Networks
Filter MBE10-8 (Main)
Frames with destination addresses corresponding to remote workstation address table or broadcasts
Synchronous or
Asynchronous Link
Frames with destination addresses not corresponding to remote workstation address table
MBE10-8 (Remote)
Filter
Ethernet
802.3
Frames
Remote LAN
Figure 1-2. MBE16-8 Filtering and Forwarding in Bridge Mode
Ph:727-398-5252/Fax:727-397-9610
Functional Description 1-5 www.bestdatasource.com
Chapter 1 Introduction
MBE Family
Installation and Operation Manual
Note
Bridge Mode Compatibility
Most members of the MBE range of products are intercompatible (see
Table 1-1
)
.
Additional bridges cannot be connected to the remote LAN. However, no limitations on additional bridging or routing apply to the main LAN.
Table 1-1. Bridge Mode Product Intercompatibility
Product Compatibility
Main
Remote
MBE-1**
MBE-8** NA
MBE10-1
MBE10-1D
MBE-1 MBE-8 MBE
10-1
NA
MBE
10-1D
MBE
10-8
NA NA
MBE10-8 NA
MBE10-8D NA
RR-MBE-8D NA
**
NA NA
NA NA
NA NA
Earlier version without RJ-45 control port on front panel
Indicates unconditional compatibility
MBE
10-8D
MBE-RAS MBE-
RAS/A
NA
NA
RR-MBE
10-8D
Principles of Operation
MBE10-1 Operation
The remote MBE learns the address of the remote workstation connected to it when the workstation attempts to access the network. The remote MBE then uses this workstation address to request the local MBE to insert into the local (main)
LAN. The remote MBE forwards all frames originating from the remote workstation. The local MBE will forward to the link only those frames destined for the remote workstation including broadcast and multicast messages, unless they have been masked out.
MBE10-1D Operation
The remote MBE units on both links update the local MBE with the addresses of the remote workstation attached to it. Each remote MBE forwards to the link all frames destined for the local LAN. The local MBE forwards to a particular link only those frames destined for a workstation connected to that link. Broadcast and multicast messages are forwarded to both links, unless they have been masked out.
1-6 Functional
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 1 Introduction
MBE10-8 Operation
On power-up, both the local and remote MBE10-8s will connect to their respective LANs. The remote MBE10-8 continuously learns the addresses of workstations on the remote LAN and updates the local MBE10-8 with these addresses (up to 80 addresses).
The remote MBE10-8 forwards all frames to the local LAN that are not addressed to workstations on the remote LAN. The local MBE10-8 forwards all frames that have destination addresses belonging to one of the remote workstations to the link.
Broadcast and multicast packets are always forwarded in both directions, unless they are masked out using the filtering tool (see the
LAN RANger Series
Configuration Guide
).
MBE10-8D Operation
Operational characteristics of MBE10-8D are identical, in most respects, to those of MBE10-8, except that MBE10-8D (located at the local LAN) supports connection of two remote LANs (one per link).
MBE10-8D supports up to 80 addresses per LAN providing a total of 160.
Broadcast and multicast packets are always forwarded in both directions, unless masked out using the filtering tool (see the
LAN RANger Series Configuration
Guide
). MBE10-8D can also be installed on a remote LAN where one link serves as a backup link to the other.
Functional Block Diagram
shows the functional circuitry of the MBE unit.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Functional Description 1-7 www.bestdatasource.com
Chapter 1 Introduction
Link Interface
V.35/V.24
X.21/
RS-530
4W, ISDN
MBE Family
Installation and Operation Manual
Power
Supply
Async
Port
Main
Processor and
Communication
Processor
2MB
DRAM
LAN
Processor
LAN
Interface
Filtering
Block
(not applicable to MBE10-1)
ERRORS
LINK
ERRORS
LAN
LINK Rx
LINK Tx
LAN Rx
LAN Tx
READY
MAIN
REMOTE
POWER
MAIN/REM
Switch
LAN
CONN
AUI
BNC
UTP
Control
RJ-45
Figure 1-3. MBE Functional Block Diagram
MBE is comprised of the following main circuits (see
•
LAN interface
•
LAN processor
•
Bridge mode filtering block (MBE 10-8 and MBE-10-8D only)
•
Link interface
•
Main processor and communication processor
• Power supply
• Asynchronous port.
LAN Interface
The LAN interface provides the physical connection to an Ethernet LAN via various media types: UTP (10BaseT), BNC (10Base2), or AUI (10Base5). The LAN interface contains receiver and transmitter functions, and clock extraction.
LAN Processor
The LAN processor performs the Media Access Control (MAC) protocols of the
Ethernet, i.e., transmission and reception of frames according to the main processor's requests, and transmission of LAN status information to the main processor.
1-8 Functional
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 1 Introduction
Bridge Mode Filtering Block (MBE10-8 and MBE10-8D only)
In addition to MBE10-1 functions, MBE10-8 and MBE10-8D have a filtering block.
The filtering block in the local MBE compares the destination address of every frame transmitted on the main LAN to the table of remote workstation addresses.
The result of the filtering block comparison generates a
copy/not copy frame
command for the LAN processor.
If a frame is addressed to one of the remote workstations, the local MBE forwards this frame to the link. The remote MBE compares the destination address of every frame transmitted on the remote LAN with the remote workstation address table.
All frames in the remote LAN, containing destination addresses not included in the remote workstation address table, will be forwarded to the link by the remote
MBE.
If the frame destination address is of the broadcast or multicast type, the filtering block compares the source address of the frame to the remote workstation address table. This source address check results in a
copy/not copy
command for the LAN processor.
Link Interface
The link interface provides the physical connection to either V.24/RS-232, V.35,
RS-530, V.36, 4W, X.21, ISDN or DDS links. The 4W interface provides an internal short range modem with internal clock. DCE mode is provided for bench testing by V.24 and V.35 link interfaces. In DCE mode, the internal clock rate can be adjusted by selecting options from the internal clock rate setup menu (see
"Internal Clock Rate Setup"
in the
LAN RANger Series Configuration Guide
).
Main Processor and Communication Processor
The main processor controls the LAN and communication processors. It performs buffer management and transfers the frames received from the LAN for transmission to the link and vice versa.
The communication processor provides an HDLC link for transmission and reception of frames to the main processor. Error checks and retransmissions ensure an error-free link.
Power Supply
The MBE power supply provides required operating voltages. The power supply input ranges between 100 VAC to 240 VAC.
Asynchronous Control Port
Management
The RJ-45 control port provides setup, configuration, and monitoring and download interface using an asynchronous ASCII terminal as a terminal emulator.
Quick setup and configuration is performed via a terminal emulator attached to the control port, or via TELNET access to the device over the LAN or WAN.
An SNMP agent provides in-band or out-of-band management by RADview or by any other standard SNMP management station.
Software downloading is available through the control port, using XMODEM, and through the LAN or WAN using TFTP. Parameter file downloading and uploading is available through the LAN or WAN using TFTP.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Functional Description 1-9 www.bestdatasource.com
Chapter 1 Introduction
MBE Family
Installation and Operation Manual
Product configurations and software are saved in flash memory. Two versions of the software are stored for redundancy.
LAN Interface
Standard
Type
LINK
Interface
1.4 Technical Specifications
Connectors
Interface/
Connectors
Protocol
Data Rates
Conforms to Ethernet/IEEE 802.3
10Base5 (AUI)
10Base2 (BNC) (Thin Coax)
10BaseT (UTP)
10Base5: 15-pin D-type, female
10Base2: BNC female
10BaseT: RJ-45
V.35*: 34-pin female
V.24/RS-232*: 25-pin D-type, female
X.21: 15-pin D-type, female (through adapter cable)
V.36/RS-422: 37-pin D-type, female (through adapter cable)
RS-530: 25-pin D-type, female
4W: 5-screw terminal block
Basic Rate ISDN
("S" or "U" interface) – RJ-45
CSU/DSU: RJ-45
Note
: *The interface can function as DTE or DCE.
Synchronous: HDLC-based
Asynchronous: Programmable UART
V.24/RS-232 (Synchronous): up to 64 kbps
V.24/RS-232 (Asynchronous): 2.4 to 115.2 kbps
V.35, X.21, V.36/RS-422, RS-530: up to 1.5 Mbps
4W: 16 to 768 kbps (selectable, internal clock)
DDS: up to 56 kbps
Basic Rate ISDN: 56, 64, 112, 128 kbps
1-10 Technical
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 1 Introduction
Control
Interface
Type
Connector
V.24/RS-232
RJ-45
LED
Indicators
Data Rate
2.4 to 19.2 kbps, 8 bits, No Parity,
Automatic rate detection
POWER (green)
On when the unit is powered-up
READY (green)
On when packets can be transferred
MAIN (green)
On when the unit is configured as local (applicable to
Bridge mode only)
REMOTE (green)
On when the unit is configured as remote (applicable to
Bridge mode only)
LAN TX (yellow)
On when a packet is being transmitted to the LAN
LAN RX (yellow)
On when a packet is being received from the LAN
LAN ERR (red)
On when LAN interface indicates an error
LINK TX* (yellow)
On when a packet is transmitted to link
Blinks (every 15 seconds) when a synchronous link is connected and the link is open
LINK RX* (yellow)
On when a packet is being received from the link
Blinks (every 15 seconds) when a synchronous link is connected and the link is open
LINK ERR* (red)
On when the serial link interface indicates an error
Blinks when the serial link interface indicates an error
Panel
Controls
Note:
*Refers to both Link 1 and Link 2 for dual port models
Reset
Power ON/OFF
Power Supply
Voltage
Frequency
Power
Front panel
Rear panel
100–240 VAC (
±
10%)
50/60 Hz
10 VA Max
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Technical Specifications 1-11 www.bestdatasource.com
Chapter 1 Introduction
Physical
Height
Length
Width
Weight
Environment
Temperature
Humidity
MBE Family
Installation and Operation Manual
4.4 cm/ 1.8 in (1U)
30 cm/11.8 in
21.6 cm/8.5 in
2.1 kg /4.7 lb
0
°
–50
°
C/32
°
–122
°
F
0 to 90%, non-condensing
1-12 Technical
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Chapter 2
Installation
This chapter describes the basic installation procedures for the MBE unit, including:
• Site requirements and prerequisites
• Package contents
•
Equipment needed
•
Installation and setup.
Note
2.1 Introduction
MBE is delivered completely assembled. For instructions on installation of a single unit or two units in a 19-inch rack refer to the
Rack Mounting Kit for 19-inch Racks
guide that comes with the RM kit.
After installing the unit, see
Chapter 3
,
Operation
for operating instructions.
In case a problem is encountered, refer to
Chapter 4
for fault isolation and troubleshooting instructions.
Any adjustments, maintenance or repairs should be performed only by a skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and maintenance of this product.
2.2 Site Requirements and Prerequisites
Inspect the equipment container before unpacking. Note and report evidence of damage immediately to your RAD distributor.
Install the MBE unit within 1.5m (5 ft) of a grounded AC outlet furnishing
240V (115V).
Allow at least 90 cm (36") of frontal clearance for operator access. Allow at least
10 cm (4") clearance at the rear of the unit for interface cable connections.
The ambient temperature should be regulated between 0
°
to 50
°
C
(32
°
F to 122
°
F) at a relative humidity of up to 90%, non-condensing.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Chapter 2 Installation
MBE Family
Installation and Operation Manual
2.3 Package Contents
The following items are included in the MBE product packaging:
•
One MBE standalone unit
• Control cable with RJ-45 connector – CBL-RJ45/D9/F/6FT
• AC power cord
• MBE Family Installation and Operation Manual
•
LAN RANger Series Configuration Guide.
2.4 Equipment Needed
The following equipment is required to install the MBE:
•
ASCII terminal or PC terminal emulator
•
CBL-RJ45/D9/F/6FT control cable with RJ-45 connector (supplied with the device) for connection to the configuration terminal.
2.5 Installation and Setup
MBE is a standalone unit intended for tabletop or bench installation. It is delivered completely assembled. No provision is made for bolting the unit on the tabletop.
To install the MBE unit:
1. Determine the required configuration of MBE and set the internal jumpers accordingly.
2. Connect the line (see
below ).
3. Connect the LAN (see
).
4. Connect power to the unit (see
below ).
Warning
Access to the inside of the equipment is permitted only to authorized and qualified personnel.
To avoid accidental electric shock, always disconnect the interface cables and power cord before removing the unit from its casing.
Any adjustment, maintenance or repair of the opened instrument under voltage must be avoided as much as possible, and when inevitable, should be carried out only by a skilled technician who is aware of the hazards involved.
2-2
Order from: Cutter Networks
Installation and Setup
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 2 Installation
Configuring MBE
This section describes how to configure MBE for a typical application.
Bridge Application
Typically, MBE is used in a bridge application. In bridge mode, MBE units operate in pairs, with one MBE unit located at the main Ethernet LAN, and a second
MBE unit located at the remote LAN. Each MBE unit is configured differently depending on its location and the application. Configuration is performed through hardware switches and menu-driven software. See the
LAN RANger Series
Configuration Guide
for software configuration instructions.
illustrates the layout of the MBE printed-circuit board.
provides details on the functions of the internal jumpers and switches,
and their default settings.
To configure the MBE unit:
1. Disconnect the MBE power cord. It is not sufficient to turn off the POWER switch on the rear panel.
2. Unscrew the cover screw located at the rear of the unit and keep it in a safe place.
3. Remove the MBE cover.
4. Determine the required configuration of the MBE unit and set the internal jumpers and switches accordingly (see
5. Configure the MBE LOCATION (SW1):
REMOTE – MBE is located on the remote LAN
MAIN – MBE is located on the main LAN.
6. Set the Chassis GND Jumper Setting (JP7) between the signal ground and the chassis (protective) ground (see
and
ON – connect
NC – disconnect
7. With the 4-wire option:
Use the rotary switch on the 4W link interface card (see
a data rate. The data rate may also be selected via the software (see the
LAN RANger Series Configuration Guide
for software configuration instructions). The data rates for maximum required range are listed in
8. In bench testing, where one MBE is configured as DTE and the other as DCE configure the MBE link interface:
DCE
DTE – for normal operation (see
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Installation and Setup 2-3 www.bestdatasource.com
Chapter 2 Installation
MBE Family
Installation and Operation Manual
9. To enable direct connection between MBE and a UTP interface in any workstation, set the STATION/HUB Switch to STATION (see
available only with the UTP option.
10. Replace the MBE cover.
11. Close by tightening the cover screw.
12. Proceed with the line, LAN and power connections as described below.
Warning
In certain locations where permanent excessive high voltages are present on the lines, setting JP7 to NC may render the unit unsafe for connection to unprotected telecommunication networks.
Link Interface
Module
LAN Interface
Module
AUI
BNC
UTP
Fuse
240 VAC/2A
Slow-Blow
Power Supply
EPROM
512K
128K
LOCATION
SW1
MAIN
REMOTE
NC
JP7
CHASSIS
ON
RESET
SW2
Figure 2-1. MBE PCB Layout
WATCH DOG
OFF ON
2-4
Order from: Cutter Networks
Installation and Setup
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 2 Installation
Table 2-1. MBE Switches and Jumpers
Switch/Jumper
SW1
JP7
Name
LOCATION
CHASSIS
(Ground
Connection)
Reference Possible
Settings
Factory
Setting
Description
REMOTE
MAIN
MAIN
MBE is located on the remote LAN.
MBE is located on the main (local)
LAN.
NC
(Not Connected)
ON
(Connected)
NC Disconnect signal ground from chassis
(protective) ground.
Connect signal ground to chassis
(protective) ground.
Reset RESET
(Front panel button)
EPROM SIZE
WATCH DOG
CLOCK SPEED
(4W Interface only)
DTE/DCE Jumper
(V24, V35 Interface only)
STATION HUB
Switch
(UTP Interface only)
512 KB
128 KB
OFF
ON
7
– 16 kbps
6
– 32 kbps
5
– 48 kbps
4
– 64 kbps
3
– 96 kbps
2
– 128 kbps
1
– 256 kbps
0
– 768 kbps
DTE
DCE
STATION
HUB
128 KB
ON
768 kbps
DTE
HUB
For manufacturer's use only.
For manufacturer's use only.
Select data rate on 4-wire internal modem.
Select the highest possible data rate for respective range and wire gauge.
Select DTE mode for normal operation.
Select DCE mode for bench testing.
Interchanges the Rx pair with the Tx pair.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Installation and Setup 2-5 www.bestdatasource.com
Chapter 2 Installation
MBE Family
Installation and Operation Manual
Note
BOT
0
7 6
1
5
2
3
4
Rate
768
256
128
96
64
48
32
16
POS
0
1
2
5
6
3
4
7 7
BOT
0
6
1
5
2
3
4
Rate
768
256
128
96
64
48
32
16
POS
0
1
2
5
6
3
4
7
IL-4W IL-4WD
Figure 2-2. 4W Date Rate Selection
TOP
0
7
6
1
5
2
3
4
BOT- corresponds to the lower link connector.
TOP - corresponds to the upper link connector.
Table 2-2. MBE Four-Wire Data Rate
Data Rate
(kbps)
Range
km
/
miles
Selector Position
768 1.0/0.6 0
256 3.0/1.8 1
128 4.5/2.7 2
96 5.5/3.3 3
64 6/3.7 4
48 7/4.3 5
32 6.5/4.0 6
16 6/3.7 7
2-6
Order from: Cutter Networks
Installation and Setup
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual
Link-2 TOP
DTE
DCE
Link-1 BOTTOM
DTE/DCE
Jumper
Chapter 2 Installation
DTE
DCE
DTE/DCE
Jumper
Note
V.24D, V.35D, V.24
Figure 2-3. Link Interface Card
LINK-2 corresponds to the upper interface connector.
LINK-1 corresponds to the lower interface connector.
V.35 Interface
V.35
6
STN HUB
Figure 2-4. LAN Interface Module (UTP)
Connecting the Interfaces
illustrates the MBE unit’s rear panel with a V.35 connector.
illustrates the MBE unit’s rear panel with a V.24 connector.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Installation and Setup 2-7 www.bestdatasource.com
Chapter 2 Installation
I O
POWER
AUI
MBE Family
Installation and Operation Manual
TO V.35 LINE
100-230 VAC
Figure 2-5. MBE Rear Panel, V.35 Connector
I O
POWER
AUI
TO RS-232/V.24
100-230 VAC
I O
POWER
AUI
LINK 2 RS-232/V.24
LINK 1 RS-232/V.24
100-230 VAC
Figure 2-6. MBE Rear Panel, V.24 Connector
Connecting the Line
A connector is provided to connect each interface to the communication link.
To connect the line:
•
See
Appendix A
for LINK connector pin assignments. Note that the X.21 and
V.36 connections are provided by adapter cables to the RS-530 (25-pin connector) on the MBE rear panel.
Interface cards are interchangeable. Consult your RAD dealer for details.
Connecting the LAN
To connect to the LAN:
•
Use a standard AUI (15-pin, D-type), 10Base2 (BNC) or 10BaseT (RJ-45) connector, provided by RAD.
Caution
To ensure compliance with electromagnetic compatibility (EMC) requirements, it is recommended that you only use shielded data cables with this product. Make sure that the shield is connected to the metallic hood of the cable connector.
For units with V.35 ports, in order to protect against electrostatic discharge (ESD) into the port, use a connector with an overlapping hood that completely covers the pin connection.
2-8
Order from: Cutter Networks
Installation and Setup
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 2 Installation
Connecting the Power
AC Power
Supply AC power to the MBE unit through the 1.5m (5 ft) standard power cable terminated by a standard 3-prong plug. The cable is provided with the unit.
A 2A slow-blow fuse is located in the power supply unit.
To prevent electrical fire hazard, always replace the fuse with the same type and rating as indicated.
Warning
➤
To connect AC power to the MBE unit:
1. Connect the power cable to the power connector on the MBE rear panel.
2. Connect the power cable to the mains outlet.
3. Set the POWER switch to ON.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Installation and Setup 2-9 www.bestdatasource.com
Chapter 2 Installation
MBE Family
Installation and Operation Manual
2-10
Order from: Cutter Networks
Installation and Setup
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Chapter 3
Operation
This chapter:
•
Describes MBE front panel controls and indicators
•
Provides basic operation instructions.
For in-depth information on configuration of MBE, see the
LAN RANger Series
Configuration Guide
.
3.1 Front Panel Controls and Indicators
lists the functions of the MBE controls and indicators located on the front panel.
MBE-8
LAN
RAN ger
RESET
CONTROL
POWER
READY
MAIN
REMOTE
LAN
LINK
TX RX ERR
MBE-8D
LAN
RAN ger
CONTROL
RESET
POWER
READY
MAIN
REMOTE
LAN
LINK 1
TX
LINK 2
RX ERR
Figure 3-1. MBE Front Panel
Table 3-1. Front Panel Controls and Indicators
Controls and Indicators Color
RJ45 SOCKET
(CONTROL)
POWER
READY
Green
Green
Function
LAN RANger Series
Configuration Guide
for software initiated reset
Used for connection of terminal for diagnostics, configuration, monitoring and downloading
On when MBE is powered on
On continuously during normal operation
Order from: Cutter Networks
Front Panel Controls and Indicators
Ph:727-398-5252/Fax:727-397-9610
3-1 www.bestdatasource.com
Chapter 3 Operation
MBE Family
Installation and Operation Manual
Table 3-1. Front Panel Controls and Indicators (Cont.)
Controls and Indicators Color
MAIN Green
REMOTE
LAN
TX
RX
ERR
LINK
TX
RX
ERR
Green
Yellow
Yellow
Red
Yellow
Yellow
Red
Function
On when MBE is configured for local operation (applicable to bridge mode only)
On when MBE is configured for remote operation (applicable to bridge mode only)
On when packets are being transmitted to the LAN
On when packets are being received by the LAN
On continuously when connection to LAN has failed
On when a packet is being transmitted to the link
On when a packet is being received from the link
On when discontinuity occurs in the link or if other
Communication link faults exist
3.2 Operating Instructions
Warning
GROUNDING - This unit should always be grounded through the protective earth lead of the power cable.
Before connecting AC power to this unit, the mains plug should be inserted only into a socket outlet provided with a protective earth contact. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding). Interruption of the protective (grounding) conductor (inside or outside the unit), or disconnection of the protective earth terminal can render this unit dangerous.
Initial Setup
To begin configuring MBE:
1. Connect MBE to an ASCII terminal or a PC terminal emulator.
2. Connect the CBL-RJ45/D9/F/6FT control cable, supplied with MBE, between the RJ-45 control port on the MBE front panel, and the DB-9 connector on the terminal.
3. Set the terminal to work at any baud rate from 4.8 to 19.2 kbps, No Parity,
8 data bits, and 1 stop bit.
Note
It is suggested to use 9.6 kbps.
For complete configuration details, see the
LAN RANger Series Configuration
Guide
.
3-2 Operating
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 3 Operation
Power-on
To power-up MBE:
1. Set the POWER switch on the rear panel to the ON position.
The POWER indicator lights up, indicating that MBE is powered on. After about 1 minute, the operational status screen appears on the terminal screen.
2. Press the <
Enter
> key several times to display the password prompt.
Operating MBE
To operate MBE:
1. Configure MBE according to the application (see the
LAN RANger Series
Configuration Guide
).
2. During normal operation (when the remote workstations are active):
The READY indicator lights up continuously
The Tx and Rx indicators blink occasionally
The LAN and LINK error indicators remain OFF.
Power-off
To power-off MBE:
•
Set the POWER switch on the rear panel to the OFF position.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Operating Instructions 3-3 www.bestdatasource.com
Chapter 3 Operation
MBE Family
Installation and Operation Manual
3-4 Operating
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Chapter 4
Troubleshooting and
Diagnostics
This chapter provides:
•
A procedure for performing a ping connectivity test
•
Troubleshooting solutions for possible operational and communication problems.
4.1 Diagnostic Test
Ping Terminal
To check the status of the MBE unit's connectivity, you initiate a ping test to all connected IP addresses.
To perform the ping test:
1. In the Main menu, type
5
(Diagnostic Tools).
2. Type (Ping Terminal).
3. Type your terminal's IP address and press
<Enter>
.
The results of the Ping test appear on the screen and run continuously until you stop the test.
4. To stop the ping test, press
<Enter>
.
4.2 Alarms and Troubleshooting
Observe safety precautions while working on the unit, especially if the cover is removed.
Warning
Some common faults and their solutions are listed in the
may occur due to incorrect configuration settings with regard to MBE application and location. Link errors are sometimes caused by loose contact between connectors or lack of cable continuity.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Alarms and Troubleshooting 4-1 www.bestdatasource.com
Chapter 4 Troubleshooting and Diagnostics
MBE Family
Installation and Operation Manual
If a persistent fault condition occurs, check that both MBE units are properly configured. Check that all connectors are plugged in properly and that the cable quality is good.
You can retrieve the MBE error messages by connecting a terminal to the MBE unit's control port and calling up the MBE monitoring program.
Table 4-1. Troubleshooting Guide
Symptom
All front panel indicators are OFF
Possible Cause
The unit is not receiving power
Corrupted frames are being received, or the physical connection is unstable
Recommended Course of Action
Check that power is being supplied to the unit
Check the fuse and replace it if necessary
(by a qualified technician only)
Check the modem configuration and cables
Red LINK ERROR indicator is blinking
(Link 1 and Link 2 for dual link models)
Red LINK ERROR indicator is
ON
(Link 1 and Link 2 for dual link models)
Red LAN ERROR indicator is blinking
Red LAN ERROR indicator is
ON
READY indicator is OFF
The LINK ERROR indicator is ON if the link is configured in synchronous mode, the link interface card set to DTE, and no clock signal is received
There is a temporary transmission problem
There is a problem with the LAN connection
If LAN ERROR indicator is ON, or all
LINK ERROR indicators are ON, there is a possible connection problem with the
LAN or Link
Check configuration settings
Check the modem configuration and cables
Check cable connections and ensure that the proper cable type is being used.
Check that the LAN is connected properly
Check LAN and Link connections
Debugging Messages
The Debug Messages log is a tool that helps detect the source or reason for operational and connectivity problems. The log provides continuous information about the MBE unit's connections, operations, and component functionality.
To view the Debug Messages log:
1. In the Main menu, type
0
(Exit).
The Operational Status Messages screen appears.
2. To start the log, type
DO
(Debug Open). View the log until you see the information that you need.
3. To exit the log, type
DC
(Debug Close).
Debug Messages Filters
You can enable and disable specific items to limit the scope of the Debug
Messages log. In this case, the log will display information only about the enabled items. This may save troubleshooting time.
4-2
Order from: Cutter Networks
Alarms and Troubleshooting
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics
To filter the Debug Messages log:
1. In the Main menu, type
0
(Exit).
The Operational Status Messages screen appears.
2. Type (Debug Open).
The Debug Messages screen appears.
3. Type (Debug Help).
A list of operational/connectivity categories appears. Each category has the values:
Enable
or
Disable
. An enabled item appears in the log, and a disabled item is not included.
4. To enable or disable items, type the number of the item and choose the appropriate value.
Resetting MBE to Factory Settings
You can reset MBE to the default factory settings. This is useful if you want to reconfigure MBE and remove previous configuration data.
To reset the MBE to the factory settings:
1. In the Main menu, type
0
(Exit).
The Operational Status Messages screen appears.
2. Type (Debug Open) to perform the reset.
The Debug Messages screen appears.
3. Type (Set Factory) to perform the reset.
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
Alarms and Troubleshooting 4-3 www.bestdatasource.com
Chapter 4 Troubleshooting and Diagnostics
MBE Family
Installation and Operation Manual
4-4
Order from: Cutter Networks
Alarms and Troubleshooting
Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Appendix A
Pin Assignment
This appendix:
•
Provides information about the various interfaces and cable connections supported by MBE.
Table A-1. Interface Signal List (Female Connectors)
Signal Function Source
Protective
Ground
COMMON 1
V.24/
RS-232
DB-25
(Female)
V.35*
34-PIN
(Female)
Pin Circuit Pin Circuit Pin Circuit Pin Circuit
A Frame
101
EIA-530
DB-25
(Female)
V.36/
RS-449**
DB-37
(Female)
X.21***
DB-15
(Female)
1 1 1
Description
Chassis ground. May
Signal
Ground
Transmitted Data
Received Data
Request to Send
Clear To Send
Data Set Ready
Data Terminal
Ready
Carrier Detect
COMMON 7
DTE
DCE
DTE
DCE
2
3
4
5
B Signal 102
GND
S TD(B) 103
P TD(A) 103
R RD(A) 104
T RD(B) 104
C RTS
D CTS
105
106
[GND]
Common Signal and
DC power supply ground
2 BA(A)
14 BA(B) 9 T(B)
[TRANSMIT]
Serial data output from unit. The data transitions must occur on the rising edge of the transmit clock.
RD(A)
24 RD(B)
4 R(A)
11 R(B)
Serial data input to the unit. The data
[RECEIVE] the rising edge of the clock.
4
19 CA(B)
5
CA(A)
CB(A)
7 RS(A)
9 CS(A)
13 CB(B)
3 C(A)
10 C(B)
[CONTROL]
--
ON from the unit upon completion of self-test
Unit expects CTS ON
DCE 6 E DSR 107 6 CC(A) 11 DM(A)
22 CC(B)
DTE 20 H 12 TR(A)
30 TR(B)
DCE 8 F DCD 109
-- ON when unit is ready to transmit or receive data
5
12
I(A)
I(B)
[INDICATION]
Unit expects DCD ON 8 CF(A) 13 RR(A)
10 CF(B)
Order from: Cutter Networks
A-1 www.bestdatasource.com
Ph:727-398-5252/Fax:727-397-9610
Appendix A Pin Assignment
MBE Family
Installation and Operation Manual
Table A-1. Interface Signal List (Female Connectors) (Cont.)
Signal Function Source
Transmit Clock
Receive
Clock
DCE
V.24/
RS-232
DB-25
(Female)
15
V.35*
34-PIN
(Female)
Y SCT(A) 114
A SCT(B) 114
EIA-530
DB-25
(Female)
15 DB(A)
12 DB(B)
V.36/
RS-449**
DB-37
(Female)
5 ST(A)
23 ST(B)
X.21***
DB-15
(Female)
6 S(A)
13 S(B)
[SIGNAL
TIMING]
Description
Unit requires clock for synchronization
(in synchronous mode)
DCE 17 X 115
V SCR(A) 115
17 DD(A)
9 DD(B)
8 RT(A)
26 RT(B) requires for synchronization
(in synchronous mode)
* The V.35 connection is made via an adapter cable (DB-25 connector to V.35-34 pin connector) for MBE 10-8D and MBE10-1D.
** The V.36/RS-449 connection is made by means of an RS-530 to V.36 conversion cable supplied with the RS-530 model.
*** The X.21 connection is made by means of an RS-530 to X.21 conversion cable supplied with the RS-530 model.
A-2
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Appendix A Pin Assignment
RS-530
Shield 1
Signal GND 7
RTS-a 4
RTS-b 19
CTS-a 5
CTS-b 13
DCD-a 8
DCD-b 10
TC-a 15
TC-b 12
RC-a 17
RC-b 9
TD-a 2
TD-b 14
RD-a 3
RD-b 16
Figure A-1. Cable – CBL-530T/21C
Cable supplied with MBE for X.21 interface
X.21 / 15-pin
1 Shield
8 Signal GND
3 C-a
10 C-b
5 I-a
12 I-b
6 S-a
13 S-b
2 T-a
9 T-b
4 R-a
11 R-b
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610
A-3 www.bestdatasource.com
Appendix A Pin Assignment
MBE Family
Installation and Operation Manual
V.35/ DB-25 V.35/ 34-pin
Shield
Tx
Rx
R Clk
E Clk
T Clk
RTS
CTS
DCE Ready
Gnd
DCD
DTE Ready
24
11
15
12
4
5
6
7
8
20
1
2
14
3
16
17
9
Figure A-2. Cable – CBL-530/V.35/F
Cable supplied with MBE10-1D, 8D for V.35 interface
B
F
H
C
D
E
U
W
Y
AA (a)
S
R
A
P
T
V
X
Tx
Rx
A-4
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
MBE Family
Installation and Operation Manual Appendix A Pin Assignment
Order from: Cutter Networks
RS-530
Shield
TD-a
TD-b
RD-a
RD-b
RTS-a
RTS-b
CTS-a
CTS-b
DSR-a
DSR-b
DTR-a
DTR-b sig. GND
DCD-a
DCD-b
TC-a
TC-b
RC-a
RC-b
LL
RL
EXT-CK-a
EXT-CK-b
TM
9
18
21
24
11
25
23
7
8
10
15
12
17
4
19
5
13
6
22
20
1
2
14
3
16
RS-449/V.36-37 pin
6
24
7
25
1
4
22
Shield
SD-a
SD-b
RD-a
RD-b
RS-a
RS-b
CS-a
9
27
11
29
12
CS-b
DM-a
DM-b
TR-a
14
17
35
18
23
8
26
10
30 TR-b
19,20,37 SG
13
31
5
RR-a
RR-b
ST-a
ST-b
RT-a
RT-b
LL
RL
TT-a
TT-b
TM
Figure A-3. Cable – CBL/449/F
Cable supplied with MBE for V.36 interface
MBE/4-Wire
Local
MBE/4-Wire
Remote
Tx
Rx
GND
SHIELD
Figure A-4. Four-Wire (4W) Connection
Tx
Rx
GND
Ph:727-398-5252/Fax:727-397-9610
A-5 www.bestdatasource.com
Appendix A Pin Assignment
MBE Family
Installation and Operation Manual
RJ-45 socket
1 2 3 4 5 6 7 8
Rx pair: pins 3 and 6
Tx pair: pins 1 and 2
Figure A-5. 10BaseT Connection (for UTP Ethernet)
Table A-2. Control Cable RJ-45 to DB-9 Connection (DCE)
RJ-45 DB-9
Pin 4 GND
Pin 5 TX
Pin 6 RX
Pin 7 RTS
Pin 8 CTS
Pin 5 GND
Pin 2 RX
Pin 3 TX
Pin 8 CTS
Pin 7 RTS
Table A-3. ISDN "S" Interface Cable Pin Assignments
Pin Number Signal Name
3 Tx+
4 Rx+
5 Rx–
6 Tx–
A-6
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
—B—
bridge mode, 1-5 bridges, 1-2
—C—
clock, 2-5
COD, 1-3 configuration, 2-3 initial setup, 3-2 control interface, 1-11 control port, 1-9
CSLIP, 1-1
—D—
datagrams, 1-2 debug, 4-2
DC, 4-2
DO, 4-2 log, 4-2
—E—
errors, 4-2
—F—
filtering block, 1-9 firewall, 1-3 flash, 1-3, 1-4, 1-10 frame relay, 1-1 front panel, 3-1 normal operation, 3-3
—I—
installation, 2-2 interfaces, 1-9 connection, 2-7
IP routing, 1-1
IP/IPX support, 1-2
ISDN, 1-3
—J—
jumpers, 2-5
Index
Order from: Cutter Networks
—L—
LAN, 1-8 connection, 2-8 interface, 1-10 processor, 1-8
LEDs, 1-11 line connection, 2-8 link interface, 1-9, 1-10
—M—
MAC protocols, 1-8 management, 1-2
MBE compatibility, 1-6 front panel, 1-4 management, 1-9 operation, 1-6 rear panel, 1-4 site requirements, 2-1
MTU, 1-2
—P—
panel controls, 1-11
PAP/CHAP, 1-3 pin assignment, A-1 ping, 4-1 power, 1-11, 2-9, 3-3 power supply, 1-9, 1-11
PPP, 1-1
—Q—
Quick Setup, 1-3
—R—
RADview, 1-2 reset, 1-11 reset factory settings, 4-3 routers, 1-1, 1-2 routing mode, 1-5
—S—
security, 1-3
Single IP, 1-3
SLIP, 1-1
SNMP management, 1-2
Ph:727-398-5252/Fax:727-397-9610
I-1 www.bestdatasource.com
Index switches, 2-5
—T—
technical specifications, 1-10
TELNET, 1-2
MBE Family
Installation and Operation Manual troubleshooting, 4-2
—X—
XMODEM, 1-9
I-2
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-6458181, Fax: +972-3-6483331, +972-3-6498250 www.rad.com
Customer Response Form
RAD Data Communications would like your help in improving its product documentation.
Please complete and return this form by mail or by fax or send us an e-mail with your comments.
Thank you for your assistance!
Manual Name:
Publication Number:
__________________________________________________________
Please grade the manual according to the following factors:
Installation instructions
Operating instructions
Manual organization
Illustrations
Excellent Good
❒
❒
❒
❒
❒
❒
❒
❒
❒
❒
Fair
❒
❒
❒
❒
❒
Poor Very Poor
❒
❒
❒
❒
❒
❒
❒
❒
❒
❒
The manual as a whole
What did you like about the manual?
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Error Report
Type of Error(s) or Problem(s):
❒
❒
❒
❒
Incompatibility with product
Difficulty in understanding text
Regulatory information (Safety, Compliance, Warnings, etc.)
Difficulty in finding needed information
❒ Missing
❒
❒
Illogical flow of information
Style (spelling, grammar, references, etc.)
❒ Appearance
❒ Other
Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.) and attach the page to your fax, if necessary.
_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
Please add any comments or suggestions you may have.
_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
You are: ❒ Distributor
❒ End
❒ VAR
❒ Other
Who is your distributor? _______________________________
Your name and company: ___________________________________________________________
Job title: __________________________________________________________________________
Address: __________________________________________________________________________
Direct telephone number and extension: _______________________________________________
Fax number: ______________________________________________________________________
E-mail:
_____________________________________________________________________
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
www.rad.com
INTERNATIONAL HEADQUARTERS:
24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181
Fax: 972-3-6498250, 972-3-6474436, Email: [email protected]
U.S. HEADQUARTERS:
900 Corporate Drive, Mahwah, N.J. 07430, Tel: (201) 529-1100
Toll Free: 1-800-444-7234, Fax: (201) 529-5777, Email: [email protected]
Publication No. 572-200-02/03
Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 15 Overview
- 15 General
- 15 Versions
- 16 Applications
- 16 Features
- 18 Physical Description
- 19 Functional Description
- 19 General
- 20 Principles of Operation
- 21 Functional Block Diagram
- 23 Management
- 24 Technical Specifications
- 27 Introduction
- 27 Site Requirements and Prerequisites
- 28 Package Contents
- 28 Equipment Needed
- 28 Installation and Setup
- 29 Configuring MBE
- 33 Connecting the Interfaces
- 34 Connecting the Line
- 34 Connecting the LAN
- 35 Connecting the Power
- 37 Front Panel Controls and Indicators
- 38 Operating Instructions
- 38 Initial Setup
- 39 Power-on
- 39 Operating MBE
- 39 Power-off
- 41 Diagnostic Test
- 41 Ping Terminal
- 41 Alarms and Troubleshooting
- 42 Debugging Messages