OWNER`S MANUAL

DROLET EPA WOODSTOVES

SIBERIAN-1200 SIBERIAN-1600 SIBERIAN-2000

US ENVIRONMENTAL PROTECTION

AGENCY PHASE II CERTIFIED

WOODSTOVES

Vérified and tested following

ULC S627 et UL 1482 Standards by:

Intertek Testing Services

READ AND KEEP THIS MANUAL FOR REFERENCE

Manufactured by : STOVE BUILDER INTERNATIONAL INC..

1700, Léon-Harmel, Québec (Québec) G1N 4R9

Tel : ( 418 ) 527-3060

Fax : ( 418 ) 527-4311 www.drolet.ca

990812/45065A_Feb 03

TABLE OF CONTENTS

INTRODUCTION............................................................................................................... 2

TECHNICAL SPECIFICATIONS ....................................................................................... 3

ASSEMBLY ....................................................................................................................... 4

PEDESTAL AND DECORATIVE SIDEWALL INSTALLATION ...................................... 4

BRICKS INSTALLATION (SIBERIAN-1200).................................................................. 5

BRICKS AND INSULATION INSTALLATION (SIBERIAN-1600) ................................... 6

BRICK AND INSULATION INSTALLATION (SIBERIAN 2000) ..................................... 7

AIR TUBES INSTALLATION (SIBERIAN 2000): ........................................................... 8

DOOR ADJUSTMENT ................................................................................................... 9

THE BENEFITS OF INSTALLING A BLOWER ............................................................... 10

INSTALLATION............................................................................................................... 11

POSITIONING THE STOVE ........................................................................................ 11

FLOOR PROTECTOR ................................................................................................. 12

CLEARANCES ............................................................................................................ 13

REDUCED CLEARANCES .......................................................................................... 14

CHIMNEY .................................................................................................................... 15

CHIMNEY CONNECTOR (STOVE PIPE).................................................................... 16

TYPICAL INSTALLATIONS ......................................................................................... 17

WOODSTOVE UTILIZATION.......................................................................................... 21

AVERAGE ENERGY YIELD OF ONE AIR DRIED CORD OF CUT WOOD ................ 21

TESTING YOUR WOOD ............................................................................................. 22

THE FIRST FIRES....................................................................................................... 22

IGNITION..................................................................................................................... 22

HEATING..................................................................................................................... 23

CREOSOTE FORMATION AND NEED FOR REMOVAL............................................ 24

ASH DISPOSAL .......................................................................................................... 25

MAINTENANCE .............................................................................................................. 26

GLASS......................................................................................................................... 26

GASKETING................................................................................................................ 26

PAINT .......................................................................................................................... 26

LIMITED LIFETIME WARRANTY.................................................................................... 27

1

INTRODUCTION

SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes to help you get maximum satisfaction from your wood stove. In the pages that follow, we will give you advice on wood heating and controlled combustion as well as technical specifications regarding installation, operation and maintenance of the model you have chosen.

The instructions pertaining to the installation of your wood stove comply with ULC-S627 and UL-1482 standards.

Read this entire manual before you install and use your new stove. If this stove is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Failure to follow instructions may result in property damage, bodily injury, or even death.

Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit.

Keep this instructions manual for future references.

CAUTIONS:

HOT WHILE IN OPERATION . KEEP CHILDREN , CLOTHING AND FURNITURE AWAY . CONTACT MAY

CAUSE SKIN BURNS .

DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE .

DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED .

DO NOT BURN WASTES , FLAMMABLE FLUIDS SUCH AS GASOLINE , NAPHTHA OR MOTOR OIL .

DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM .

ALWAYS CLOSE THE DOOR AFTER THE IGNITION .

2

TECHNICAL SPECIFICATIONS

Combustion Type:

Recommended Surface

Heating Capacity :

Efficiency :

Average Emission:

Colors :

Flue Pipe Diameter :

Chimney type :

Minimum Chimney Height :

Maximum Log Length :

Dimensions

Overall

Combustion Chamber :

Width x Depth :

Door Opening :

E.P.A :

Width x Height :

SIBERIAN-1200 SIBERIAN-1600 SIBERIAN-2000

Wood Wood Wood

600 à 1 200 ft

(56 à 112 m

2

2

)

900 à 1 600 ft

(84 à 149 m

2

2

)

1 000 à 2 000 ft

2

(93 à 186 m

2

)

36 000 BTU/h

(10,5kW)

45 000 BTU/h

(13,2 kW)

40 000 BTU/h

(11,7 kW)

70 000 BTU/h

(20,5 kW)

60 200 BTU/h

(17,6 kW)

95 000 BTU/h

(27,8 kW)

73% 71,3% 72,2%

6,5 g/h 3,3 g/h 3,8 g/h

Anthracite and burgundy

6’’ (152 mm)

Anthracite and burgundy

6’’ (152 mm)

Anthracite and burgundy

6’’ (152 mm)

2 100°F (650 °C)

12’ (3,66 m)

16’’ (406 mm)

2 100°F (650 °C)

12’ (3,66 m)

18’’ (457 mm)

2 100°F (650 °C)

12’ (3,66 m)

19’’ (483 mm)

W x D x H

23 7/8 x 23 x 29 ¾’’

(607 x 584 x 756mm)

18 x 14’’

(457 x 356 mm)

1,5 pi

3

(0,04 m

3

)

15 ¼’’ x 7 ½’’

(387 x 191 mm)

W x D x H

26 3/8 x 27 x 32 5/8‘’

(671 x 686 x 828mm)

18 ¼ x 15 ¼’’

(464 x 387 mm)

2,5 pi

3

(0,07 m

3

)

16 ¾ x 8 ¾’’

(425 x 222 mm)

W x D x H

30 x 29 ¼ x 34 ¼’’

(762 x 743 x 870mm)

22 ½ x 18’’

(572 x 457 mm)

3,4 pi

3

(0,09 m

3

)

20 3/8 x 7 ¼’’

(518 x 184 mm)

Pyroceram Glass Door :

Width x Height :

15 ½’’ x 8 ½’’

(394 x 216 mm)

17 x 10 ½’’

(432 x 267 mm)

20 ½ x 8 ¾’’

(521 x 222 mm)

Mass: 263 lbs ( 119 Kg) 380 lbs (172 Kg)

OPTIONS

Blower 75 CFM (2,83 m

3

/min) with

Yes Yes variable speed control

Thermodisc 100-120 o

F (37-49

0

C). Yes Yes

510 lbs (231 Kg)

Yes

Yes

3

ASSEMBLY

PEDESTAL AND DECORATIVE SIDEWALL INSTALLATION

Figure 1: SIBERIAN-1200 and 1600

Pedestal Installation :

1. Remove all bricks and insulations in the appliance.

2. Slowly, lay down the stove on his back.

3. Install legs or the pedestal with the supplied nuts and bolts. Stand up the stove and place it with the required clearances. Note that there is eight holes in the bottom of the stove but only four will align with the pedestal.

4. Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supplied screws.

5. Slide the ash pan in position (for

Deluxe model only).

Side Panels Installation :

1. Fix the front part of the decorative side with two screws supplied. The oblong holes allow to adjust the height of the side 3\16" (5 mm) above the top of the stove.

2. Then, fix the back on the decorative side with three screws and washers supplied. Line up the decorative side in relation to the side of the appliance.

Figure 2: SIBERIAN-2000

4

BRICKS INSTALLATION (SIBERIAN-1200)

Refractory bricks are to be installed according to figure 4.

In both stoves, the baffle brick must be pushed as close to the front as possible onto its metallic support.

The upper bricks (2) must lay on the vertical bricks (4) grove

Note that a plain brick is supplied instead of a ashtray cap on standard models.

Figure 3: SIBERIAN-1200

5

BRICKS AND INSULATION INSTALLATION (SIBERIAN-1600)

1. Remove from the stove all bricks and insulation.

2. Install all side bricks (12 x 4 1/2" x 9")

3. Install the back bricks (6 x 4 1/2" x 9")

4. Install the bottom bricks (4 x 4 1/2" x 9") + (2 x 6" x 7").

5. Install the "T" shape support and the bricks (4 x 4 1/2" x 9") + (2 x 3" x 9").

6. Install the baffle bricks (4 x 4 1/2" x 9") + (2 x 3" x 9") on T shape support.

7. Finally gently slide the insulation panels over the baffle bricks.

Figure 4: SIBERIAN-1600 Refractory Bricks Assembly

6

BRICK AND INSULATION INSTALLATION (SIBERIAN 2000)

The stove is normally supplied with secondary air tubes in position. To install the baffle bricks and white ceramic insulation, it’s necessary to remove the two front secondary air tubes. First place only one baffle brick and one white ceramic insulation. Use the same method to put the other baffle brick and insulation. Put back in place the secondary air tubes.

Install the yellow insulation and the 6" x 8" or 6" x 6" bricks. Install the side and bottom bricks.

Figure 5: Siberian 2000 Refractory Bricks Assembly

7

AIR TUBES INSTALLATION (SIBERIAN 2000):

The secondary air tubes are painted different colours . The back tube is yellow, the middle one is red and the front is unpainted. Before installing, make sure the locating holes in the tubes (holes near one end of the tube) are on the left side. Insert one tube in the right side air channel and slide it to the right as much as possible. Bring the left end of the tube aligned with the ring welded to the left air channel. Move the tube to the left until the locating holes are aligned with those in the ring. Insert a cutter pin to hold in place. The air injection holes should be facing down in the front and middle tubes.

Figure 6: Air Tubes Installation

8

DOOR ADJUSTMENT

In order for your stove to operate properly, the door should be adjusted periodically to provide an air tight fit. To adjust:

• Remove the lock pin (spring pin) by pulling and turning it using pliers ("wise grip")

• Turn the handle counter clock wise one turn to increase pressure

• Re-install the lock pin (spring pin) with a small hammer

Figure 7: Door Adjustment

9

THE BENEFITS OF INSTALLING A BLOWER

A blower can be installed at the back of your DROLET stove. This option is necessary if you wish to redistribute into a room the heat trapped at the back of your stove. By forcing hot air toward the front, the blower enables you to extend the radiation power of your stove.

You can purchase this option through your DROLET dealer. Make sure to specify this part number: #AC02050. You can also install a thermodisc to enable the blower to start or stop automatically when the stove is hot or too cold. The thermodisc part number is AC05530.

Installation instructions are supplied with the blower and the thermodisc.

10

INSTALLATION

SAFETY NOTICE

• I

F THIS STOVE IS NOT PROPERLY INSTALLED , A HOUSE FIRE MAY RESULT . T O REDUCE THE RISK

OF FIRE , FOLLOW THE INSTALLATION INSTRUCTIONS . F AILURE TO FOLLOW INSTRUCTIONS MAY

RESULT IN PROPERTY DAMAGE , BODILY INJURY , OR EVEN DEATH .

• C

ONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT RESTRICTIONS

AND INSTALLATIONS REQUIREMENTS IN YOUR AREA .

• U

SE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED .

• K

EEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE .

• N

EVER USE GASOLINE , GASOLINE TYPE LANTERN FUEL , KEROSENE , CHARCOAL LIGHTER FLUID ,

OR SIMILAR LIQUIDS TO START OR " FRESHEN UP " A FIRE . KEEP ALL SUCH LIQUIDS WELL AWAY

FROM THE STOVE .

• I

N THE EVENT OF A CHIMNEY FIRE , PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE

OF OXYGEN . C ALL THE FIRE DEPARTMENT .

• D

O NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM .

• A

SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN

REQUIRED .

POSITIONING THE STOVE

It is very important to position the wood stove as close as possible to the chimney, and in an area that will favour the most efficient heat distribution possible throughout the house.

The stove must therefore be installed in the room where the most time is spent, and in the most spacious room possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a wood stove. A wood stove also functions by convection, that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary, the hot air distribution from the stove may be facilitated by the installation of a blower.

The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occur.

A wood stove must never be installed in a hallway or near a staircase, since it may block the way in case of fire or fall to respect required clearances.

11

FLOOR PROTECTOR

Your wood stove should be placed on a non-combustible surface. The floor protector should be under the stove, eighteen inches beyond the front and eight inches beyond each side of the fuel loading and ash removal opening. If there is a horizontal section of chimney connector, the floor protector should go under it and two inches beyond each side.

The floor protector should exceed the stove as follows:

FRONT SIDES BACK

18’’

(460 mm)

8’’

(200 mm)

8’’

(200 mm)

12

CLEARANCES

It is of utmost importance that the clearances to combustible material be scrupulously respected upon installation of the stove you have selected. Refer to the tables below :

CANADA

SIBERIAN-1200

Figure 8: Clearances to combustibles

Single wall pipe / Double wall pipe

A B C D E F

15/10 8/8 7/6 20.4/15.4

20/20 19.4/18.4

USA

SIBERIAN-1200

Single wall pipe / Double wall pipe

A B C D E F

17/12.5 8/8 10/7 22.4/17.9

20/20 22.4/19.4

• Floor to ceiling height must be at least 7' (84") in all cases.

• The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe.

• The flue pipe must not go through roof trussing, an attic, a wardrobe or similar spaces; neither a floor or combustible partition.

• A flue pipe crossing a combustible wall must have a clearance of 18" minimum.

• To reduce flue pipe clearances from combustible materials, contact your local safety department.

13

REDUCED CLEARANCES

You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. These heat radiation shields must be installed permanently, and can include sheet metal, a rigid non-combustible sheet or a masonry wall.

Clearances of not less than 1" (25 mm) and not more than 3" (76 mm) between the bottom of the shield and the floor and not less than 3" (76 mm) between the top of the shield and the ceiling must be respected to allow vertical air circulation behind the shield.

The shield must extend 20" (500 mm) above the stove top and 18" (450mm) to each side of the stove.

Following the installation of such a heat radiation shield, the clearances mentioned on the stove certification plate may be reduced as stated in the following table.

TYPE OF PROTECTION

Reducing Clearances With

Shielding

Sides and

Rear/Back

Top

Sheet metal, a minimum of 0,013" (0,33 mm) spaced out at least 7/8" (21 mm) by non-combustible spacers.

Ceramic tiles, or an equivalent non-combustible material on fire-proof supports spaced out at least 7/8"

(21 mm) by non-combustible spacers.

Ceramic tiles, or an equivalent non-combustible material on fire-proof supports with a minimum of

0,013" (0,33 mm) sheet metal backing spaced out at least 7/8" (21 mm) by non-combustible spacers.

Brick spaced out at least 7/8" (21 mm) by noncombustible spacers.

Brick with a minimum of 0,013" (0,33 mm) sheet metal backing spaced out at least 7/8" (21 mm) by noncombustible spacers.

Source: CSA Standard B365-1991, Table 4, Page 27

67% 50%

50% 33%

67% 50%

50% N/A

67% N/A

14

CHIMNEY

Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must comply with UL 103 or ULC S629 standards; therefore it must be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer's specifications.

If you are using a masonry chimney, it is important that it be built in compliance with the specifications of the National Building Code. It must be lined with fire clay bricks, metal or clay tiles sealed together with fire cement. (Round flues are the most efficient).

The interior diameter of the chimney flues must be identical to the stove's smoke exhaust.

A flue which is too small may cause draught problems, while a large flue favours rapid cooling of the gas, and hence the build-up of creosote and the risk of chimney fires. Note that it is the chimney and not the stove which creates the draught effect; your stove's performance is directly dependent on an adequate draught from your chimney.

The following recommendations may be useful for the installation of your chimney:

1. Do not connect this unit to a chimney flue serving another appliance.

2. It must rise above the roof at least 3' (0.9 mm) from the uppermost point of contact.

3. The chimney must exceed any part of the building or other obstruction within a

10' (3.04 m) distance by a height of 2' (0.6 m).

4. Installation of an interior chimney is always preferable to an exterior chimney.

Indeed, the interior chimney will, by definition, be hotter than an exterior chimney, being heated up by the ambient air in the house. Therefore the gas which circulates will cool more slowly, thus reducing the build-up of creosote and the risk of chimney fires.

5. The draught caused by the tendency for hot air to rise will be increased with an interior chimney.

6. Using a fire screen at the extremity of the chimney requires regular inspection in order to insure that it is not obstructed thus blocking the draught, and it should be cleaned when necessary.

15

CHIMNEY CONNECTOR (STOVE PIPE)

Your chimney connector and chimney must have the same diameter as the stove outlet. If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draught.

The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of

0.021" or 0.53 mm. It is strictly forbidden to use galvanized steel.

Your smoke pipe should be assembled in such a way that the male section of the pipe faces down. Attach each of the sections to one another with three equidistant metal screws.

The pipe must be short and straight. All sections installed horizontally must slope at least

1/4 inch per foot, with the upper end of the section toward the chimney.

To insure a good draught, the total length of the coupling pipe should never exceed 8' to

10' (24 to 3.04 m). (Except for cases of vertical installation, cathedral-roof style where the smoke exhaust system can be much longer and connected without problem to the chimney at the ceiling of the room).

There should never be more than two 90 degrees elbows in the smoke exhaust system.

Installation of a "barometric draught stabiliser" (fireplace register) on a smoke exhaust system is prohibited.

Furthermore, installation of a draught damper is not recommended. Indeed, with a controlled combustion wood stove, the draught is regulated upon intake of the combustion air in the stove and not at the exhaust.

Stove Pipe

16

TYPICAL INSTALLATIONS

FACTORY BUILT CHIMNEY:

RAIN CAP

ROOF FLASHING

18" CLEARANCE

WALL RADIATION SHIELD

WALL SUPPORT

Wall installation

RADIATION SHIELD

Vertical installation

CEILING SUPPORT

17

MASONRY CHIMNEY:

Thim b le

C lay line r

C lea n out door

18

FACTORY BUILT THIMBLE:

19

BRICK THIMBLE:

20

WOODSTOVE UTILIZATION

Your heating unit was designed to burn wood only; no other materials should be burnt.

Wastes and other flammable materials should not be burnt in your wood stove. Any type of wood may be used in your stove, but specific varieties have better energy yields than others. Please consult the following table in order to make the best possible choice.

Average Energy Yield Of One Air Dried Cord Of Cut Wood

High energy yield

Wood species

Energy yield

(millions of BTU/cord)

Oak 29

Sugar Maple 28

Beech 26

Yellow birch 25

Ash 24

Elm 23

Larch (Tamarack) 23

Red Maple

Douglas red fir

Silver birch

23

23

22 Medium energy yield

Alder 18

Poplar 17

Hemlock 17

Spruce 17

Pine 17

Low energy yield

Bass 16

Fir 13

Data provided by Energy, Mines and Resources - Canada

IT IS EXTREMELY IMPORTANT THAT YOU USE DRY WOOD ONLY IN YOUR WOOD

STOVE. The wood must have dried for 9 to 15 months, such that the humidity content (in weight) is reduced below 20% of the weight of the log. It is very important to keep in mind that even if the wood has been cut since one, two or even more years, it is not necessarily dry, if it has been stored in poor conditions; under extreme conditions, it may even rot instead of drying. The vast majority of the problems related to the operation of a wood stove are caused by the fact that the wood used was too damp or had dried in poor conditions. These problems can be:

• ignition problems

• creosote build-up causing chimney fires

• low energy yield

• blackened windows

• incomplete log combustion

21

Smaller pieces of wood will dry faster. All logs exceeding 6" in diameter should be split.

The wood should not be stored directly on the ground. Air should circulate through the cord. A 24" to 48" air space should be left between each row of logs, which should be placed in the sunniest location possible. The upper layer of wood should be protected from the element but not the sides.

TESTING YOUR WOOD

When the stove is thoroughly warmed, place one piece of split wood (about five inches in diameter) parallel to the door on the bed of red embers.

Keep the air control fully open by pulling on it and close the door. If ignition of the piece is accomplished within 90 seconds from the time if was placed in the stove, your wood is correctly dried. If ignition takes longer, your wood is damp.

If your wood hisses and water or vapour escapes at the ends of the piece, your wood is soaked or freshly cut. Do not use this wood in your stove. Large amounts of creosote could be deposited in your chimney, creating potential conditions for a chimney fire.

THE FIRST FIRES

The fresh paint on your stove needs to be cured to preserve its quality. Once the fuel charge is properly ignited, only burn small fires in your stove for the first four hours of operation. Never open the air control more than necessary to achieve a medium burn rate.

Make sure that there’s enough air circulation while curing the stove. The odours could be smelled during the 3 or 4 first fires. Never start your stove outside. You will not be able to see if you are over heating.

IGNITION

After making sure that the stove air intake controls are fully open (completely pull-out towards you), place several rumpled sheets of paper in the centre of the combustion chamber. Place 8 to 10 pieces of small dry kindling wood over the paper in the form of a tent. You may also place a few pieces of heating wood, but choose the smaller ones. No chemical product should be used to light the fire.

Before igniting the paper and kindling wood, it is recommended that you warm up the chimney. This is done in order to avoid back draft problems often due to negative pressure in the house. If such is the case, open a window slightly near the stove and twist together a few sheets of newspaper into a torch. Light up this paper torch and hold it as close as possible to the mouth of the pipe inside the combustion chamber to warm up the chimney. Once the updraft movement is initiated, you are ready to ignite the stove by lighting the paper and kindling wood inside the combustion chamber.

We therefore advise you to leave the door slightly opened (1/4") for a 10 to 30 minutes period, under supervision, in order to allow for good combustion. After this time, you must close the door and progressively adjust the air control to obtain the desired temperature.

22

HEATING

Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for each given situation. The wood will burn slowly if the wood stove air intake control is adjusted to reduce the oxygen supply in the combustion chamber to a minimum. On the other hand, wood will burn quickly if the air control is adjusted to admit a larger quantity of oxygen in the combustion chamber. The air intake control on your stove is very simple. If you pull on it out completely towards you, it is fully open. If you push on it until it stops the combustion air is reduced to a minimum.

The following burn rates will be achieved according to control setting.

Medium high

High

SIBERIAN-1200 full close 7/16" 7/8" full open

SIBERIAN-1600

SIBERIAN-2000 full close 1/4" full close 1/2"

SIBERIAN-1200 Air Control

5/8"

1" full open full open

OPENING

SIBERIAN-1600 Air Control

OPENING

SIBERIAN-2000 Air Control

OPENING

Please note that the SIBERIAN-1200 and SIBERIAN-2000 series stoves do not have the same operating range. The SIBERIAN-1200 type stove burned between 0.69 kg/h and

2.69 kg/h, the SIBERIAN1600 between 0.93 and 3.32 kg/hr during EPA testing. The 2000 serie achieved between 0.95 kg/h and 4.9 kg/h under the same conditions . Real operating conditions may give very different results than those obtained in the lab according to the species of wood used, its moisture content, the size and density of the pieces, the length of the chimney, altitude, outside temperature.

23

RELOADING

Once you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air controls to maximum a few seconds prior to opening the stove's door.

Then proceed by opening the door very slowly; open it one or two inches for 5 to 10 seconds, before opening it completely to increase the draught and thus eliminate the smoke which is stagnant in a state of slow combustion in the stove. Then bring the red embers to the front of the stove and reload the unit.

For optimal operation of your wood stove, we recommend you operate it with a wood load approximately equivalent to the height of fire bricks.

It is important to note that wood combustion consumes ambient oxygen in the room .In the case of negative pressure, it is a good idea to allow fresh air in the room, either by opening a window slightly or by installing a fresh air intake system on an outside wall. Refer to page 16 of the present manual.

WARNINGS

• N

EVER OVERFIRE YOUR STOVE . I F ANY PART OF THE STOVE STARTS TO GLOW RED , OVER

FIRING IS HAPPENING . R EADJUST THE AIR INTAKE CONTROL AT A LOWER SETTING .

• T

HE INSTALLATION OF A LOG CRADLE IS NOT RECOMMENDED IN YOUR DROLET WOOD STOVE .

• N

EVER PUT WOOD ABOVE THE FIREBRICK LINING OF THE FIREBOX .

CREOSOTE FORMATION AND NEED FOR REMOVAL

When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire. When burning wood, the chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote build-up has occurred.

We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe, approximately 18" above the stove. This thermometer will indicate the temperature of your gas exhaust fumes within the smoke exhaust system. The ideal temperature for these gases is somewhere between 275 o

F and 500 o

F. Below these temperatures, the build-up of creosote is promoted. Above 500 degrees, heat is wasted since a too large quantity is lost into the atmosphere.

TO PREVENT CREOSOTE BUILD UP

• Always burn dry wood. This allows clean burns and higher chimney temperatures, therefore less creosote deposit.

• Leave the air control full open for about 10 min. every time you reload the stove to bring it back to proper operating temperatures. The secondary combustion can only take place if the firebox is hot enough.

• Always check for creosote deposit once every two months and have your chimney cleaned at least once a year.

24

ASH DISPOSAL

Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold, such as in the morning.

Always dispose of ashes in a metal container with a tight fitting lid. Place this container on a non combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the close container until all cinders have thoroughly cooled.

CAUTIONS:

• A

SHES COULD CONTAIN HOT EMBERS EVEN AFTER TWO DAYS WITHOUT OPERATING THE STOVE .

• T

HE ASH PAN CAN BECOME VERY HOT . W EAR GLOVES TO PREVENT INJURY .

• N

EVER BURN THE STOVE WITH THE ASH TRAP OPEN . T HIS WOULD RESULT IN OVER FIRING THE

STOVE . D AMAGE TO THE STOVE AND EVEN HOUSE FIRE MAY RESULT .

25

MAINTENANCE

Your Drolet stove is a high efficiency stove and therefore require little maintenance. It is important to perform a visual inspection of the stove every time it is emptied, in order to insure that no parts have been damaged, in which case repairs must be performed immediately.

GLASS

• Inspect the glass regularly in order to detect any cracks. If you spot one, turn the stove off immediately. Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is broken.

• If the glass on your stove breaks, replace only with glazing supplied from the Drolet dealer.

• To replace the glass, remove the screws retaining the glass mouldings inside the door.

Remove the mouldings and replace the damaged piece with a new one. Perform the procedure backwards after replacing. When replacing the glass, you should change the glass gasket to make sure you keep it sealed.

• Never wash the glass with a product that may scratch. Use a specialized product, available in the stores where wood stoves are sold.

• The glass should be washed only when cold.

GASKETING

It is recommended that you change the door gasket (which makes your stove door air tight) once a year, in order to insure good control over the combustion, maximum efficiency and security. To change the door gasket, simply remove the damaged one.

Carefully clean the available gasket groove, apply a high temperature silicone sold for this purpose, and install the new gasket. You may light up your stove again approximately 24 hours after having completed this operation.

WARNING:

• N

EVER OPERATE THE STOVE WITHOUT A GASKET OR WITH A BROKEN ONE . D AMAGE TO THE

STOVE OR EVEN HOUSE FIRE MAY RESULT

PAINT

Only clean your stove with a dry soft clothe that will not harm the paint finish.

If the paint becomes scratched or damaged, it is possible to give your wood stove a brand new look, by repainting it with a 1200 o

F heat resistant paint. For this purpose, simply scrub the surface to be repainted with fine sand paper, clean it properly, and apply thin coats (2) of paint successively. Refer to page 18 of the present manual for the paint curing process.

26

1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : [email protected] web site : www.drolet.ca

LIMITED LIFETIME WARRANTY

The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to your Drolet dealer

This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper installation, lack of maintenance, over firing, negligence or accident during transportation are not covered by this warranty.

This warranty does not cover any scratch, corrosion or discoloration caused by over firing, abrasives or chemical cleaners. Any defect or damage caused by the use of unauthorized parts or others than original parts void this warranty.

An authorized qualified technician must perform the installation in accordance with the Instructions supplied with this product and all local and national building codes. Any service call related to an improper installation is not covered by this warranty.

Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will repair or replace such defect and reasonable transportation fees will be refund.

Repair work covered by the warranty, executed at the purchaser domicile by an authorized qualified technician requires the prior approval of the manufacturer. Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the replacement part.

The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect. The manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts

The manufacturer shall in no event be responsible for any special, indirect, consequential damages of any nature, which are in excess of the original purchase price of the product.

DESCRIPTION

WARRANTY APPLICATION

PARTS LABOUR

Combustion chamber (weldings only)

Stainless baffle

Carbon steel baffle

Handle assembly

Ash drawer

Cast iron parts

Lifetime

5 years

2 years

5 years

Lifetime

5 years

5 years

1 year

1 year n/a

1 year

1 year

Ceramic glass (thermal breakage only)

Paint, refractory bricks, gasket, blower, thermal switch (thermodisc) and rheostat

Gold plating (tarnishing)

1 year

1 year n/a n/a

1 year n/a

Shall your unit or a components be defective, contact immediately your Drolet dealer. Prior to your call make sure you have the following information necessary to your warranty claim treatment:

• You name, address and telephone number;

• Bill of sale, dealer’s name;

• Serial number and model name as indicated on the nameplate fixed to the back of your unit;

• Nature of the defect and any relevant information.

Before shipping your unit or defective component to our plant, you must obtain from your Drolet dealer an Authorization

Number. Any merchandise shipped to our plant without authorization will be refused automatically and returned to

sender.

27

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals