advertisement
Bernee Auto Tracking Dome Camera User Manual
Auto Tracking High Speed
Dome Camera
User Manual
1 / 39
Bernee Auto Tracking Dome Camera User Manual
Contents
SECTION1 INSTRUCTION ...................................................................................................................................... 3
1.1
P RODUCTION I NTRODUCING ............................................................................................................................................ 3
1.2
C
HARACTER
.................................................................................................................................................................. 3
1.3
F UNCTION D ESCRIPTION .................................................................................................................................................. 3
1.4
S PECIFICATION C OMPARISON C HART .................................................................................................................................. 7
SECTION 2 NORMAL OPERATION ....................................................................................................................... 10
2.1
D OME D IAL ‐ UP S ETTING ............................................................................................................................................... 10
SECTION 3 MENU CONFIGURATION ................................................................................................................... 13
3.1
M AIN M ENU .............................................................................................................................................................. 13
3.2
S ELECT L ANGUAGE ....................................................................................................................................................... 14
3.3
S
YSTEM
I
NFORMATION
.................................................................................................................................................. 14
3.4
D ISPLAY S ETUP ............................................................................................................................................................ 14
3.4.1 Display Setup ............................................................................................................................................... 14
3.4.2
Label Position ........................................................................................................................................ 15
3.5
D OME S ETTINGS 1 ....................................................................................................................................................... 16
3.5.1 Dome Settings 1 .......................................................................................................................................... 16
3.5.2 Camera Settings .......................................................................................................................................... 16
3.5.3 Motion Setting .............................................................................................................................................. 20
3.5.4 Power Up ...................................................................................................................................................... 23
3.5.5 Presets Setting ............................................................................................................................................. 24
3.5.6 Patterns Setting ............................................................................................................................................ 25
3.5.7 Zone Setting ................................................................................................................................................. 26
3.5.8 Clears Setting ............................................................................................................................................... 27
3.5.9 Presets Number ........................................................................................................................................... 28
3.6
D OME S ETTINGS 2 M ENU ............................................................................................................................................. 28
3.6.1 Alarms ............................................................................................................................................................ 28
3.6.2 Alarms Setting .............................................................................................................................................. 29
3.6.3 Aux Setting .................................................................................................................................................... 31
3.6.4 Password Setting ......................................................................................................................................... 31
3.6.5 Windows Blanking ....................................................................................................................................... 32
3.6.6 Set Windows ................................................................................................................................................. 33
3.6.7 Edit Windows Location ................................................................................................................................ 34
3.6.8 Edit Windows Zoom ..................................................................................................................................... 34
3.6.9 Heater Setting .............................................................................................................................................. 35
3.6.10 Cruise Setting ............................................................................................................................................. 35
3.6.11 Tracking Setting .......................................................................................................................................... 36
3.6.12 Tracking Boundary ..................................................................................................................................... 37
3.7
D
OME
L
ABEL
.............................................................................................................................................................. 38
3.8
O THER F UNCTIONS ...................................................................................................................................................... 39
2 / 39
Bernee Auto Tracking Dome Camera User Manual
Section1 Instruction
1.1 Production Introducing
The dome cameras feature high position resolution, high speed, low price and selectable communication protocols; widely used in surveillance system.
1.2 Character
Built-in English OSD Menu, by which you can change dome parameter, set or call preset, and achieve auto tour, pattern, auto scan etc.
The feature will define the activity when the dome parks.
Integrated design making it high reliability.
Auto panning function with 256 preset positions.
RS-485 data communication.
Low noise design.
With its full 360º horizontal rotation, 180º vertical auto-flip to follow object and surveillance of any subject is constant and continuous.
The speed can be adjusted automatically according to the zooming times.
Auto focus, Auto white balance.
Auto focus lens and auto white balance.
BLC
Multi protocols (Pelco-P, Pelco-D, Kalate etc).
Baud rate is changeable.
Alarm input, Alarm output, Alarm action.
The features password protection to prevent unauthorized changes to the dome setting.
A set window can be reversed so that it is the only visible tilt area of the scene. The other parts of the tilt area of the scene will be blanked.
Revolutionary motion tracking technology make it realize intelligent surveillance easily with the help of alarming function
1.3 Function Description
(1) Setting the dome ID, Baud-rate and Protocol
Every controlling command has a target camera Address, Baud-rate and Protocol, the camera
3 / 39
Bernee Auto Tracking Dome Camera User Manual only react the controlling command in accordance with its own Address, Baud-rate and Protocol.
(2) Object tracking
The dome can be manually controlled from the control system by using the joystick on the controller to move the camera up and down, right and left to follow objects under observation.
In default status AUTO IRIS and AUTO FOCUS control of the lens will automatically adjust the picture image on alteration of the background illumination to get a best view.
(3) Proportional Pan
Proportional pan automatically reduces or increases the pan and tilt speeds in proportion to the zooming times. At telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of joystick deflection then at wide zoom settings. This keeps the image from moving too fast on the monitor when there is a large amount of zoom.
(4) Auto Flip
When the dome camera tilts downward and goes just beyond the vertical, the dome camera rotates
180 degrees automatically. Afterwards, the dome camera starts moving upward even you still hold joystick in the down position. Once you let go of the joystick after the dome rotates, joystick control returns to normal operation. The auto-flip feature is useful for following a person who passes directly beneath the dome.
(5) Setup and call Preset
Preset function is that dome saves current horizontal angle and title angle of pan/tilt, zoom and position parameters into the memory. When necessary, dome calls up these parameters and adjusts
Pan/Tilt/Zoom accordingly so that the camera goes to that position again. Operator can save and call up presets easily and promptly by using keyboard controller or infrared controller. This dome supports up to
256 presets.
(6) Lens Control a. Zoom control
User can adjust camera’s zoom wide or near by using controller and get desired image. b. Focus control
System defaults Auto Focus mode, in which the lens and camera will automatically adjust the focus to give the best image.
Focus can also be controlled manually from the controller if required.
Press FOCUS NEAR or FOCUS FAR key to manually focus.
Focus can be manually controlled via keyboard or matrix, please refer to control keyboard or matrix operation manual for detailed operation.
When on manual focus status, operations such as adjusting positions or preset setting will resume the camera to auto focus status.
4 / 39
Bernee Auto Tracking Dome Camera User Manual
The camera will not auto focus in the following status.
Target is not in the center of image.
Targets are in near and far at the same time.
Target is of strong light object. Such as spotlight etc.
Target is behind the glass with water drop or dust.
Target moves too fast.
Target is too big, such as wall.
Target is too dark or vague. c. Iris control
System defaults AUTO IRIS. Camera can adjust immediately according to the alteration of back ground illumination to get a steady image.
Users may adjust Iris manually by using a controller to get required image quality.
Users can call back AUTO IRIS by moving the joystick.
(7) Auto Back-light Compensation
Lens has been divided to six areas for back light compensation. In a strong light background, camera will auto compensate the darker object and adjust light input from the lighter area to avoid a mass image that usually presents a sharp contrast of brightness and darkness.
(8) Auto White Balance
Camera can automatically adjust white balance according to the alteration of background lightness to give a true color image.
(9) Backlight Compensation (BLC)
If a bright backlight presents, the subjects in the picture may appear dark or as a silhouette.
Backlight compensation enhances objects in the center of the picture. The dome uses the center of the picture to adjust the iris. If there is a bright light source outside this area, it will change to white. The camera will adjust the iris so that the object in the sensitive area is properly exposed.
(10) Day and Night Function
The IR cut filter of camera module inside the dome can be removed by sending special command, so that the camera can change from color to mono. The picture is clear even if the illumination is as low as 0.01Lux.
(11) Auto Cruise
The preset positions are programmed for recalled in sequence. This feature is called auto cruise.
Up 30 presets can be set in each cruise tour.
(12) Patterns
5 / 39
Bernee Auto Tracking Dome Camera User Manual
A pattern is a saved moving course; the camera will repeat its pan, tilt, zoom and preset functions that can be recalled with a command from a controller or automatically by a programmed function
(alarm, park or power-up).
(13) Auto Scan
Make the dome scan 360º range in the current position.
(14) Random Scan
Make the dome random scan 360º range in the current position.
(15) Frame Scan
This feature freezes the scene on the monitor when going to a preset. This allows for smooth transition from one preset scene to another.
(16) Zones Setting
A zone is a pan area, defined by a left and right limit, on the 360-degree pan plane. The spectra dome system is capable of eight zones, each with a 6-character label.
(17) Alarms
Alarms input:
The dome has four alarm inputs, which can be programmed as high, medium or low priority. When an alarm is received, an input signal to the dome triggers the user-defined action (go to preset, run pattern, etc.) programmed for the alarm.
Auxiliary output:
An auxiliary output is a programmable signal from the dome back box that can trigger another device to operate. An auxiliary output is programmable to trigger from an alarm or from a controller.
(18) Password protection
The dome features password protection to prevent unauthorized changes to the dome settings. You can open the System Information and Display Setup screens, but cannot access any of the Dome
Settings menus.
(19) Windows blank
A set window can be reversed so that it is the only visible tilt area of the scene. All other parts of the tilt area of the scene will be blanked.
NOTE: Be the same with only the model of KTSD18NX, KTSD26NX, KTST18NX, and KTST26NX.
(20) Auto tracking
Revolutionary motion tracking technology making it realize intelligent surveillance easily with the help of alarming function
6 / 39
Bernee Auto Tracking Dome Camera User Manual
1.4 Specification Comparison Chart
Appearance mount
Auto Track Yes
Image Sensor 1/4″ Ex-view HAD color CCD
Effective Pixel 752(H)×582(V)
Horizontal
Resolution
Min. illumination
480TV Lines
0.002Lux, 0Lux/IR mount
On/Off (on: 530 TV lines)
Optical Zoom 18X,f =4.1~73.8mm(F 1.4 to 3.0)
Digital Zoom 12 X
1/60 second mode: 1.4Lux(F1.6,50IRE),
1/4 second mode: 0.1Lux(F1.6,50IRE),
0Lux/IR
36X, f=3.4~122.4mm(F 1.6 to 4.5)
12 X
320mm(wide), 1500mm(Tele)
Length
Horizontal
Field of View
Scanning
System
48°(wide)~2.8°(Tele) 57.8°(wide)~1.7°(Tele)
2:1 interlace
Sync System Internal / External (V-locking)
Focusing
System
Auto (sensitivity: normal, low) / one-click focusing / manual / alternate AF / zoom-out activate AF
Auto (sensitivity: normal, low) / one-click focusing / manual / unlimited zoom-in / alternate AF focusing / zoom-out activate
AF
Gain Control Auto / Manual (-3~28dB, 2dB stepping)
White Balance Auto, auto tracking white balance (ATW), indoor, outdoor, one-click, manual
AE Control
Super WDR
Backlight
Compensation
Auto, manual, priority modes, brightness,
EV compensation, backlight compensation
No
On / Off
Auto, manual, priority modes (shutter priority / aperture priority), brightness, EV compensation, backlight compensation, brightness compensation, slow AE
On / Off
On / Off
7 / 39
Bernee Auto Tracking Dome Camera User Manual
Electronic
Shutter
1/1~1/10, 000 seconds, 22 speed-levels
External
Control
VISCA(TTL signal power level), baud rate: 9.64Kb/s,19.24Kb/s,38.4Kb/s, stop position
1 or 2 optional
Privacy Mask On/Off (24 zones) ON / OFF (8 zones)
Picture Feature Electronic flip, backward flip, black & white, mirror
Character
Generator
Mode display, clock display, title display Mode display / multi-line OSD (OSD display prior to mode display)
Flicker
Elimination
No Auto
Video Output CVBS: 1.0Vp-p/75 ohms
SN Ratio
Pan Speed
≥50dB
0.05°~400°/s
Tilt Speed
Pan Travel
0.03°~240°/s
360° continuous
Tilt Travel
Preset
Positions
Auto Tour
90°(180° auto-flip)
256
1~30 point sequence switch
Pattern Scan 4
Zone Setting 8
Control Modes Multi-protocol, RS485
Baud Rate
Address
Range
Alarm Input
1200 bps/2400 bps/4800 bps/9600 bps/19200 bps
0~255
4 channels
Alarm Output 2 channels
OSD
Language
Chinese/English
Voltage Input AC24V
Power
Consumption
20W 50W 20W 50W
Dimension 157×205mm(W×H) 157×205mm(W×H) 238×268mm(W×H)
Weight 2.3kg
Working
Temperature
3.8kg 3.8kg
-25°C~70°C -50°C~70°C -25°C~70°C -50°C~70°C
8 / 39
Relative
Humidity
5%~90%
Bernee Auto Tracking Dome Camera User Manual
9 / 39
Bernee Auto Tracking Dome Camera User Manual
Section 2 Normal Operation
These operating instructions cover the basic operation of the dome and its features. When the dome is used with other manufacturers’ control system, please refer to the system controller’s instructions. In the event of special requirements outside the scope of this document it is prefer to contact your local distributor.
2.1 Dome Dial-up Setting
Dome own parameters such like baud rate, communication protocol and address codes should accord with the practical parameters of customer’s operation platform (i.e. keyboard controller).
Two groups of dial-up switchers lie in soleplate of dome engine
SW1 (dial-up switcher) is used to select communication protocol or baud rate. The front four switchers are used to set communication protocol, and the latter four to set baud rate.
Chart of Communication protocol & Baud rate
OFF ON OFF OFF PELCO-P
ON ON OFF
OFF
OFF PELCO-D
OFF ON OFF KALATEL
ON OFF ON OFF VICON
OFF ON ON OFF SAMSUNG
ON ON ON OFF AD
OFF OFF OFF ON PHILIPS Protocol
ON OFF OFF ON
OFF ON OFF ON
ON ON OFF ON
OFF OFF ON ON
WEIDUO
ALEC
MINKING
LC
……
DIP 5 6 7 8
2400 OFF ON OFF
OFF
OFF
Baud Rate
( bps) 9600 OFF OFF ON OFF
Reserve ……
SW2 (dial-up switcher) is used to set dome address codes. The setting adopts binary mode which can set max.256 different addresses for domes. Details in chart of dome address codes.
Chart of Dome Address Codes
10 / 39
Bernee Auto Tracking Dome Camera User Manual
14
15
16
17
18
19
20
7
8
9
10
11
12
13
…
248
249
250
251
252
253
254
255
Address
0
4
5
6
1
2
3
1 2 3 4 5 6 7 8
OFF OFF OFF OFF OFF OFF OFF OFF
ON OFF OFF OFF OFF OFF OFF OFF
OFF ON OFF OFF OFF OFF OFF OFF
ON ON OFF OFF OFF OFF OFF OFF
OFF OFF ON OFF OFF OFF OFF OFF
ON OFF ON OFF OFF OFF OFF OFF
OFF ON ON OFF OFF OFF OFF OFF
ON ON ON OFF OFF OFF OFF OFF
OFF OFF OFF ON OFF OFF OFF OFF
ON OFF OFF ON OFF OFF OFF OFF
OFF ON OFF ON OFF OFF OFF OFF
ON ON OFF ON OFF OFF OFF OFF
OFF OFF ON ON OFF OFF OFF OFF
ON OFF ON ON OFF OFF OFF OFF
OFF ON ON ON OFF OFF OFF OFF
ON ON ON ON OFF OFF OFF OFF
OFF OFF OFF OFF ON OFF OFF OFF
ON OFF OFF OFF ON OFF OFF OFF
OFF ON OFF OFF ON OFF OFF OFF
ON ON OFF OFF ON OFF OFF OFF
OFF OFF ON OFF ON OFF OFF OFF
… … … … … … … …
OFF ON OFF ON OFF ON OFF OFF
ON ON OFF ON OFF ON OFF OFF
ON ON ON ON ON ON ON ON
Finishing dial-up switchers, please insert dome engine into metal shell
Precaution: 1. when inserting engine, we must ensure engine accordant with square slot inside shell, and then fix clips of both sides.
2. When fixing clips, we must ensure hearing two “click!”, otherwise fixing incorrect.
2.2 Basic Controls for Dome
Below instructions are based on using control keyboard as controlling device.
(1) Dome Self-testing after Powered up
11 / 39
Bernee Auto Tracking Dome Camera User Manual
After powered up, the dome will conduct reset procedure. In this procedure, the dome firstly pans to the default horizontal origin point, and finally tilts to the vertical 45° position to complete the self-testing.
After the dome stops, it means the camera has completed the self-testing and is ready to receive control commands.
(2) Pan and tilt: Move joystick up, down, right, left.
(3) Set up preset
Move to next position. Then press PRESET + NUM (preset NO.)+ ENTER and the dome will save current horizontal angle and title angle of pan / tilt / zoom and position parameters into memory.
(4) Call preset
Press PRESET + NUM(Preset NO.)+ ENTER , and the dome will calls these parameters saved in memory and adjust Pan/Tilt/Zoom of the camera to that position.
Extended Presets
Presets 1 Function Presets 2
37
83
95
Clear all presets positions
Select main programming menu
19
20
28
30
99 Start auto scanning
31
32
Note : For others dynamics controllers with only 64 or 40 presets. On the menu of PRESETS
NUMBER, set it as 64 or 40. Then you can use presets listed in ‘Presets 2’ instead.
(5) Zoom: You can press IN or OUT key continuously or revolve the joystick to get desired zooming times.
(6) Focus: press FAR or NEAR key.
(7) Iris: Press OPEN or CLOSE key.
12 / 39
Bernee Auto Tracking Dome Camera User Manual
Section 3 Menu Configuration
You need to install the dome system before using this manual. Please refer to the installation packet supplied with the back box for installation instructions.
After installed properly, power up the camera. It will start a configuration sequence. After the configuration is done, the monitor will display as below.
PTOL:PELCO-D
COMM:2400,N,8,1
ADDR:0
This information will remain on the monitor until dome operation begins.
Please refer to the following pages for more about how to operate and program the camera.
Access main menu(preset 95): Please refer to the Accessing Main Menu(Preset 95) section.
(1) Move joystick to position the cursor beside menu selection.
(2) Move the joystick up or down to submenu/cursor selections.
(3) Press iris Open to confirm selection.
(4) Press iris Close to cancel selection.
(5) Below instructions are based on using control keyboard as control device.
3.1 Main Menu
Set 95# preset to access main menu.
MAIN MENU
< SYSTEM INFORMATION >
< DISPLAY SETUP >
< DOME SETTINGS 1>
< DOME SETTINGS 2>
<DOME LABLE>
RESET CAMERA
REBOOT SYSTEM
LANGUAGE ENGLISH
EXIT
Figure 3.1 MAIN MENU
Access other OSD menus:
(1) Move the joystick up or down to position the cursor beside others OSD menus.
(2) Press iris Open to confirm selection.
13 / 39
Bernee Auto Tracking Dome Camera User Manual
3.2 Select Language
The language for the on-screen menus is selectable. Available languages include English and
Chinese. The factory default language is English.
Changing the display language:
(1) In main menu move the joystick to position the cursor beside LANGUAGE.
(2) Press iris Open. The cursor moves to the right, beside the currently selected language.
(3) Move the joystick up or down to view selections. Press iris Open to confirm selection. All on-screen menus are changed into the selected language.
3.3 System Information
Move joystick to select <system information>, press Open to confirm the system information menu shown as Fig 3.2.
SYSTEM INFORMATION
COMM 9600,N,8,1
ADDRESS 255
PROTOCOL PELCO-P
PRESETS NUMBER 256
LANGUAGE ENGLISH
TEMPERATURE 36°C
BACK
EXIT
Figure 3.2 SYSTEM INFORMATION
The system information screen shows dome language, protocol, and other configuration information.
System information settings shown are not changeable in this interface. It is for reference only.
Follow the following steps to display the system information screen:
(1) Move the joystick to position the cursor beside SYSTEM INFORMATION.
(2) Press iris Open.
3.4 Display Setup
3.4.1 Display Setup
Move joystick to select <DISPLAY SETUP>, press Open to enter the display setup menu shown as
Fig3.3.
14 / 39
Bernee Auto Tracking Dome Camera User Manual
DISPLAY SETUP
PRESET LABEL ON
ZONE LABEL ON
ZOOM ON
AZIMUTH/ELEVATION ON
CAMERA LABEL ON
<LABEL POSITION>
BACK
EXIT
Figure 3.3 DISPLAY SETUP
Display setup enables you to program how labels are displayed on the monitor. The following labels are available:
PRESET LABEL: Identifying preset.
ZONE LABEL: Identifying zone.
ZOOM: Identifying zooming times.
AZIMUTH/ELEVATION: Amount of pan from 0°and the amount of tilt from 0°horizontal.
CAMERA LABEL: Identifying dome.
A preset label is displayed when a preset is called. A zone label is displayed when the system moves into a zone. The zoom ratio label is displayed when zoom is activated. Azimuth/elevation and direction labels are displayed when pan/tilt is activated. The dome label is displayed when the dome label is activated.
The following settings are available for each label:
OFF: The label is not displayed when activated.
ON: The label shows when activated.
Labels can be placed anywhere on the monitor. This feature enables you to customize the place of labels on monitor screen.
ZONE CAMERA PRESET
SAVE
RESET
AZIMUTH ZOOM
Figure 3.4 Label Position
To set a label position:
15 / 39
Bernee Auto Tracking Dome Camera User Manual
(1) Move joystick to position the cursor beside a label.
(2) Press iris Open.
(3) Move joystick to move the label up, down, left, or right.
(4) Press iris Open.
(5) Repeat steps 1 through 4 to position other labels.
(6) Move the cursor to Save and press iris Open to save settings and return to display setup menu.
3.5 Dome Settings 1
3.5.1 Dome Settings 1
Move joystick to select <DOME SETTING 1>, press Open to enter the dome setting1 menu shown as Fig3.5.
DOME SETTINGS1
<CAMERA>
<MOTION>
<POWER UP>
<PRESETS>
<PATTERNS>
<ZONES>
<CLEAR>
PRESET NUMBER 256
BACK
EXIT
Figure 3.5 Dome settings 1
3.5.2 Camera Settings
Move joystick to select <CAMERA>, press Open to enter the camera menu shown as Fig3.6.
CAMERA
ZOME LIMIT X46
BACKLIGHT COMP ON/OFF
<PROGRAM AE MODE>
<OTHERS>
BACK
Figure 3.6 CAMERA
ZOOM LIMIT:
Zoom limit enables you to define a limitation on zooming times.
16 / 39
Bernee Auto Tracking Dome Camera User Manual
BACKLIGHT COMPENSATION(BLC):
If a bright backlight presents, the subjects in the picture may appear dark or as a silhouette.
Backlight compensation enhances objects in the center of the picture. The dome uses the center of the picture to adjust the iris. If there is a bright light source outside this area, it will change to white. The camera will adjust the iris so that the object in the sensitive area is properly exposed.
There are two backlight compensation settings:
ON: Backlight compensation is activated.
OFF (default): Backlight compensation is not activated.
3.5.2.1 Program AE Mode
Move joystick to select < PROGRAM AE CORTROL >, press Open to enter the PROGRAM AE
CORTROL menu shown as Fig3.7
PROGRAM AE CORTROL
AE MODE AUTO
LOW LIGHT MODE AUTO
LOW LIGHT LIMIT 1/50
IRIS LEVEL F2.0
AGC LEVEL 0dB
BIRGHT LEVEL 0dB/F2.0
BACK
EXIT
Figure 3.7A PROGRAM AE CORTROL
PROGRAM AE COORTROL
PROGRAM AE MODE AUTO
IR CUT FILTER INISERT/REMOVE
BACK
EXIT
Figure 3.7 B PROGRAM AE CORTROL
Note: Figure 1.7A shows program AE mode, it is only for models names NVD18XX and NVD26XX.
Figure 1.7B shows program AE mode, it is only for models named NVD22XX and NVD23XXPNT.
( ) Figure 3.7A PROGRAM AE MODE setting for models named NVD18XX and NVD26XX.
AE MODE:
Settings include: AUTO, MANUAL , SHUTTER, IRIS, and BRIGHT.
LOW LIGHT MODE:
Settings include: AUTO and MANUAL.
LOW LIGHT LIMIT:
17 / 39
Bernee Auto Tracking Dome Camera User Manual
Low light limit is the maximum duration, it is in fractions of a second, that electronic shutter will remain open in low light conditions. The default setting is 1/50.
Settings include:1/2, 1/3, 1/6, 1/12, 1/25, 1/50, 1/75, 1/100, 1/120, 1/150, 1/215, 1/300, 1/425, 1/600,
1/1000, 1/1250, 1/1750, 1/2500, 1/3500, 1/6500, 1/10000.
IRIS LEVEL:
Iris level is the lens function that automatically opens and closes the iris in response to changing light conditions. The default setting is F2.0.
Settings include: F2.0, F1.6 , F1.4, Close, F22, F19, F16, F14, F11, F 9.6, F8.0, F6.8, F5.6, F4.8,
F4.0, F3.4, F2.8, F2.4.
AGC LEVEL:
AGC(Automatic Gain Control) automatically adjusts the amount of video amplification to maintain a
Full 1-volt peak-to-peak video signal output. The default setting is 0 dB.
Settings include: 0dB, 2 dB, 4 dB, 6dB, 8 dB, 10 dB, 12 dB, 14 dB, 16 dB, 18 dB, 20 dB, 22 dB, 24 dB, 26 dB, 28 dB.
BRIGHT LEVEL:
The default setting is 0 dB /F2.0.
Settings include: 0 dB /F2.0, 0 dB /F1.6, 0 dB /F1.4, 2 dB / F1.4, 4 dB / F1.4, 6 dB / F1.4, 8 dB / F1.4,
10 dB/ F1.4, 12 dB/ F1.4, 14 dB/ F1.4, 16 dB/ F1.4, 18 dB/ F1.4, 20 dB/ F1.4, 22 dB/ F1.4, 24 dB/ F1.4,
26 dB/ F1.4, 28 dB/ F1.4, Close, 0 dB /F22, 0 dB /F19, 0 dB /F16, 0 dB /F14, 0 dB /F11, 0 dB /F9.0, 0 dB
/F 8.0, 0 dB /F6.8, 0 dB /F5.6, 0 dB /F4.8, 0 dB /F4.0, 0 dB /F3.4, 0 dB /F2.8, 0 dB /F2.4.
NOTE: LOW LIGHT LIMIT, IRIS LEVEL, AGC LEVEL BRIGHT LEVEL can set only when AE MODE and LOW LIGHT MODE are set as Manual.
( ) Figure 3.7B PROGRAM AE MODE settings are for MODEL NVD18XX and NVD26XX.
AE MODE:
Settings include: AUTO, AU+IR1, AU+IR2, AU+DSS, AU+DSS+IR1, AU+DSS+IR2, AU+DSS+IR3,
SHUTTER PR, IRIS PRIO, and AGC PRIORI.
IR CUT FILTER:
Settings include: IN and OUT.
LOW LIGHT LIMIT:
Settings include: 1/1.5, 1/3, 1/6, 1/12, 1/25, 1/50.
SHUTTER:
Settings include: 1/30000, 1/10000, 1/4000, 1/2000, 1/1000, 1/500, 1/250, 1/150, 1/100, 1/50, 1/25,
1/12, 1/6, 1/3, 1/1.5.
IRIS LEVEL:
18 / 39
Bernee Auto Tracking Dome Camera User Manual
Iris level is the lens function that automatically opens and closes the iris in response to changing light conditions. The default setting is F1.6.
Settings include: F1.6, F2.2, F3.2, F4.4, F6.4, F8.8, F12, F17, F24, F34.
AGC LEVEL:
AGC(Automatic Gain Control) automatically adjusts the amount of video amplification to maintain a
Full 1-volt peak-to-peak video signal output. The default setting is 0 dB.
Settings include: 0dB, 6dB, 12dB, 18dB, 24dB, and 30dB
3.5.2.2 Other Menu
Move joystick to select < others >, press Open to enter the others menu shown as Fig3.8.
OTHERS
IR CUT FILTER AUTO
IR CUT FILTER COLOUR
AUTO IRIS ON
SHARPNESS ON
SHARPNESS LEVEL 5
AUTO WHITE BALANCE ON/OFF
R GAIN 214
B GAIN 164
BACK
EXIT
Figure 3.8A OTHER MENU
OTHERS
AUTO IRIS ON
AUTO IRIS LEVEL 91
AUTO IRIS PEAK 16
SHARPNESS ON
SHARPNESS LEVEL 39
AUTO WHITE BALANCE ON
R GAIN 652
B GAIN 427
BACK
EXIT
Figure 3.8B OTHER MENU
Note: Figure 3.8A shows Other Menu only for models named NVD18XX and NVD18XX. Figure 3.8B shows Other Menu only for the models named NVD22XX and NVD23XX.
19 / 39
Bernee Auto Tracking Dome Camera User Manual
AUTO IRIS:
Auto iris is the lens function that automatically opens and closes the iris in response to changing light conditions.
Program the auto iris to operate automatically or at a user-defined level.
OFF: Auto iris is disabled, and for manually control only.
AUTO: The iris is adjusted automatically to produce a constant video output as determined by the
Auto Iris level setting.
NOTE: If auto iris is in auto mode, it will remain that status until the iris is manually opened or closed.
The dome will return to auto mode when it pans or tilts more than 15 degrees.
AUTO SHARPNESS:
Auto sharpness enhances picture details by increasing the aperture gain of the camera and sharpening the edges in the picture.
There are two settings:
ON (default): The camera automatically keeps at a normal sharpness mode.
OFF: The sharpness of the picture is set manually by programming the sharpness level.
AUTO WHITE BALANCE:
This feature automatically processes the viewed image to retain color balance over a color temperature range. The default setting for auto white balance is ON.
R GAN: Adjusts the picture output in the red range. As you change the value, the color changes on your monitor.
B GAN: Adjusts the picture output in the blue range. As you change the value, the color changes on your monitor.
3.5.3 Motion Setting
Move joystick to select <MOTION >, press Open to enter the motion menu shown as Fig3.9.
MOTION
AUTO FLIP ON/OFF
PROPORTIONAL PAN ON/OFF
PARK TIME(MINUTES) 0
PARK ACTION NONE
SCAN SPEED(DEG/S) 1
< SET SCAN>
< MANUAL LIMIT>
< SET AZIMUTH ZERO>
< CLEAR AZIMUTH ZERO>
BACK
EXIT
20 / 39
Bernee Auto Tracking Dome Camera User Manual
FIGURE 3.9 MOTION MENU
AUTO FILP:
When the dome camera tilts downward and goes just beyond the vertical, the dome camera rotates
180 degrees automatically. Afterwards, the dome camera starts moving upward even you still hold joystick in the down position. Once you let go of the joystick after the dome rotates, joystick control returns to normal operation. The auto-flip feature is useful for following a person who passes directly beneath the dome.
There are two auto flip modes:
ON(default): Auto flip mode enabled.
OFF: Auto flip mode disabled.
PROPORTIONAL PAN:
Proportional pan automatically reduces or increases the pan and tilt speeds in proportion to the zooming times. At telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of joystick deflection then at wide zoom settings. This keeps the image from moving too fast on the monitor when there is a large amount of zoom.
There are two proportional pan modes:
ON(default): Enables the proportional pan mode.
OFF: Disables proportional pan mode. The pan speed will not depend on the zooming times.
PARK TIME:
This feature enables the dome to operate a specified activity(scan, preset, or pattern) after a programmed time of idleness.
Park time can be programmed from 1 minute to 720 minutes(12 hours), or set to zero, which disables this feature. The default setting is zero.
PARK ACTION:
This feature will define the activity when the dome parks. The following settings are available:
NONE(default): No action.
AUTO SCAN: Dome starts auto scan operation.
RANDOM SCAN: Dome starts frame scan operation.
FRAME SCAN: Dome starts frame scan operation.
PRESET 1: Dome goes to preset 1.
PRESET 8: Dome goes to preset 8.
21 / 39
Bernee Auto Tracking Dome Camera User Manual
PANTTERN 1: Dome runs pattern1.
PANTTERN 2: Dome runs pattern2.
PANTTERN 3: Dome runs pattern3.
PANTTERN4: Dome runs pattern4.
SCAN SPEED:
Scan speed is that the dome will pan when in a FRAME SCAN mode. Scan speed is adjustable from
1 to 32 via the programming menu.
SET SCAN STOPS:
Set Scan Stops are programmable stops that limit the pan range of the dome. There must be two limits, a left and a right, to define an area. The dome reverses direction frame scanning when a limit stop is reached.
To set scan stops:
(1) Move joystick to position the cursor beside set scan stops.
(2) Press iris Open.
(3) Follow the directions displayed on the monitor.
CLEAR SCAN STOPS:
To clear scan stops:
(1) Move joystick to position the cursor beside clear scan stops.
(2) Press iris Open.
(3) Follow the directions displayed on the monitor.
SET MANUAL LIMIT:
<Set manual limit > is to set the P/T/Z’s moving range.
To set manual limit:
(1) Move joystick to position the cursor beside set manual limit.
(2) Press iris Open.
(3) Follow the directions displayed on the monitor.
SET AZIMUTH ZERO:
Azimuth is the pan angle from 0°to 359°.Azimuth zero is the pan position you specify to be the
0°point. Azimuth zero is normally set to magnetic north. Once set, azimuth and compass readings are based on the set Azimuth Zero point.
22 / 39
Bernee Auto Tracking Dome Camera User Manual
To program azimuth zero:
(1) Move joystick to position the cursor beside set azimuth zero.
(2) Press iris Open.
(3) Follow the directions displayed on the monitor.
CLEAR AZIMUTH ZERO:
(1) Move joystick to position the cursor beside CLEAR AZIMUTH ZERO.
(2) Press iris Open
(3) Follow the directions displayed on the monitor.
3.5.4 Power Up
Move joystick to select <power up>, press Open to enter the power up menu shown as Fig3.10.
POWER UP
POWER UP ACTION NONE
BACK
EXIT
FIGURE 3.10 POWER UP
POWER UP ACTION:
This setting defines a specific activity(scan, preset, pattern) to be performed after the dome is powered up.
Following settings are available:
NONE(default): No action.
AUTO SCAN: Dome starts auto scan operation.
RANDOM SCAN: Dome starts random scan operation.
FRAME SCAN: Dome starts frame scan operation.
PRESET 1: Dome goes to preset 1.
PRESET 8: Dome goes to preset 8.
PATTERN 1:Dome runs pattern 1.
PATTERN 2:Dome runs pattern 2.
PATTERN 3:Dome runs pattern 3.
PATTERN 4:Dome runs pattern 4.
23 / 39
Bernee Auto Tracking Dome Camera User Manual
3.5.5 Presets Setting
Move joystick to select <PRESETS>, press Open to enter the presets menu shown as Fig3.11.
PRESETS
PRESET NUMBER 1
… PRESET NOT DEFINEO…
< EDIT PRESET LABEL >
< EDIT PRESET SCAENE >
< CLEAR PRESET >
BACK
EXIT
Figure 3.11 PRESET
The dome camera has 64 programmable preset positions.
Follow below steps to program a preset.
(1) Select preset number a. Move joystick to position the cursor beside PRESET NUMMBER, press iris Open. b. Move the joystick up or down to view selections. Press iris Open to confirm selection.
(2) Edit preset label a. Move joystick to position the cursor beside EDIT Preset label. b. Press iris Open. It will show:
PRESET NUMBER 1
PRESET LABLE 1 - - - - -
0 1 2 3 4 5 6 7 8 9 Y Z y z
A B C D E F G H I J K L M N O P Q R S T U V W X a b c d e f g h I j k l m n o p q r s t u v w x
INPUT MODE CHARACTER
OK CN SP BP
Figure 3.12 CHARACTER INPUT c. Move joystick to position the cursor beside a character. Press iris Open to confirm selection. To clear a character, position the cursor beside BPE, and then press iris Open. d. After the label is inputted, move the cursor to Ok, then press iris Open to save and return to the
Preset menu.
24 / 39
Bernee Auto Tracking Dome Camera User Manual e. After the label is inputted, move the cursor to CE, then press iris Open to cancel and return to the
Preset menu.
(3) Edit preset scene a. Move joystick to position the cursor beside EDIT PRESET SCENE. b. Press iris Open. c. Follow the direction displayed on the monitor.
(4) Clear a preset a. Move joystick to position the cursor beside CLEAR PRESET. b. Press iris Open. c. Follow the direction displayed on the monitor.
3.5.6 Patterns Setting
Use stick to select <patterns> Open to enter the patterns menu shown as Fig3.13.
PATTERNS
PATTERN NUMBER 1
<PROZGRSM PATTERN>
<CLEARE PATTERN>
BACK
EDIT
Figure 3.13 PATTERNS
PROGRAME PATTERN:
A pattern is function that the camera can save its moving course, and will repeat that course when demanded.
To program a pattern:
(1) Move joystick to position the cursor beside PATTERN NUMBER, and then press iris Open.
(2) Move the joystick up or down to view selections. Press iris Open to confirm selection.
(3) Move joystick to position the cursor beside PROGRAM PATTERN.
(4) Press iris Open.
(5) Follow the directions displayed on the monitor.
After a pattern is programmed, the remaining storage percentage will be displayed on the screen.
This is the amount of memory available to program the remaining patterns.
CLEAR PATTERN:
25 / 39
Bernee Auto Tracking Dome Camera User Manual
(1) Move joystick to position the cursor beside CLEAR PATTERN.
(2). Press iris Open.
(3) F0llow the directions displayed on the monitor.
3.5.7 Zone Setting
Move joystick to select <ZONES>, then press Open to enter the zones menu shown as Fig 3.14.
ZONES
ZONE NUMBER 1
… ZONE NOT DEFINEO …
<EDIT ZONE LABEL>
<EDIT ZONE>
ZONE ENABLED ON
<CLEAR ZONE >
BACK
EXIT
FIGURE 3.14 ZONES SETTING
A zone is pan area, defined by a left and right limit on the 360-degree pan plane. There are altogether eight zones, each can be with a 6-character label.
TO program a zone:
(1) Move joystick to position the cursor beside ZONE NUMBER. Press iris Open.
(2) Move the joystick up or down to view selections. Press iris Open to confirm selection.
(3) Move joystick to position the cursor beside EDIT ZONE.
(4) Press iris Open. The Zone programming window will show on the monitor.
(5) Follow the directions displayed on the monitor. After the left stops and right limit stops are set, the Zones menu reappears with the ZONE ENABLED option set to be ON.
To edit a zone label:
(1) Move joystick to position the cursor beside EDIT ZONE LABEL.
(2) Press iris Open. It will show as follows:
26 / 39
Bernee Auto Tracking Dome Camera User Manual
ZONE NUMBER 1
ZONE LABLE 1 - - - - -
0 1 2 3 4 5 6 7 8 9 Y Z y z
A B C D E F G H I J K L M N O P Q R S T U V W X a b c d e f g h I j k l m n o p q r s t u v w x
INPUT MODE CHARACTER
OK CN SP BP
Figure 3.15 ZONE SETTING
(3) Move joystick to position the cursor beside a character. Press iris Open to confirm selection. To clear a character, position the cursor beside BP, and then press iris Open.
(4) When a label is inputted, move the cursor to Ok, then press iris Open to save and return to the
Preset menu.
(5) When a label is inputted, move the cursor to CN, then press iris Open to cancel and return to the
Preset menu.
To clear a zone:
(1) Move joystick to position the cursor beside CLEAR ZONE.
(2) Press iris Open. Follow the instructions on the screen.
Note: The ZONE NUMBER 9 is the dome’s label.
3.5.8 Clears Setting
Move joystick to select <CLEARS>, then press Open to enter the clears menu shown as Fig 3.16.
CLEARS
CLEAR ZONES
CLEAR PARESETS
CLEAR PATTERNS
RESTORE FACTORY DEFAULTS
BACK
Figure 3.16 CLEARS SET
CLEAR ZONES:
Clear all zones. To clear a specific zone, please refer to ZONES section.
LEAR PRESETS:
27 / 39
Bernee Auto Tracking Dome Camera User Manual
Clear all presets. To clear a specific preset, please refer to the PRESETS section.
CLEAR PATTERNS:
Clear all patterns. To clear a specific pattern, please refer to the PATTERNS section.
RESTORE FACTORY DEFAULTS:
This is to restore leaving-factory’s default settings.
3.5.9 Presets Number
This is to set the dome’s preset number.
3.6 Dome Settings 2 Menu
Move joystick to select <DOME SETTINGS 2>, then press Open to enter the dome settings 2 menu shown as Fig 3.17.
DOME SETTINGS 2
<ALARMS>
<AUX>
<PASSWORD>
<WINDOWS BLANKING>
<HEATER SETTING>
CRUISE SETTING
TRACKING SETTING
BACK
EXIT
Figure 3.17 DOME SETTINGS
3.6.1 Alarms
Move joystick to select <ALARMS>, then press Open to enter the alarms menu shown as Fig 3.18.
ALARMS
ALARM NUMBER 1
SEQUENCE(SECS) 1
< ALARM SETTINGS >
<CLEAR SET>
BACK
EXIT
Figure 3.18 ALARMS
The dome has seven alarm inputs, which can be programmed as high, medium or low priority. When an alarm is received, the inputted signal to the dome triggers the user–defined action(go to preset, run pattern, etc.) programmed for the alarm.
28 / 39
Bernee Auto Tracking Dome Camera User Manual
There are three alarm settings:
ALARM NUMBER:
Use this to select alarms number.
SEQUENCE<SECS>:
This is the time the dome will perform an alarm activity when more than one alarm of the same priority occurs at the same time.
RESET DELAY<SECS>:
This is the length of time the dome considers the alarm to be active after it has physically cleared.
3.6.2 Alarms Setting
Move joystick to select <ALARM NUMBER>, then press Open to enter the alarm number menu shown as Fig 3.19.
ALARM NUMBER 1
ALARM PRIORITY LOW
ALARM ACTION NONE
ACTIVATE AUX OPEN
ALARM CONTACT OPEN
BACK
EXIT
Figure 3.19 ALARM SETTINGS
Follow below steps to program alarm settings.
Select alarm number:
(1) a. Move joystick to position the cursor the cursor beside ALARM NUMBER. b. Press iris Open. c. Move the joystick up or down to view selections. Press iris Open to confirm selection.
(2) Move the joystick to position the cursor beside Alarm Settings. Press iris Open.
Select alarm priority:
(1) Move joystick to position the cursor beside Alarm Priority.
(2) Press iris Open.
(3) Move the joystick up or down to view the available selections. Available settings include HIGH,
MEDIUM, and LOW(default). If multiple alarms with different priorities are active at the same time, the dome will only go to the alarms with the highest priority.
(4) Press iris Open to confirm selection.
Set alarm action :
29 / 39
Bernee Auto Tracking Dome Camera User Manual
(1) Move joystick to position the cursor beside Alarm action.
(2) Press iris Open.
(3) Move the joystick up or down to view the available selections. Below are the settings for alarm action:
NONE: No action when alarm is triggered.
PRESET: Dome goes to the preset that is the same as the alarm number. E.g. preset 1 will go to
Alarm 1.
PATTERN 1: Dome runs pattern 1 when alarm is triggered.
PATTERN 2: Dome runs pattern 2 when alarm is triggered.
PATTERN 3: Dome runs pattern 3 when alarm is triggered.
PATTERN 4: Dome runs pattern 4 when alarm is triggered.
AUTO SCAN: Dome starts auto scan operation when alarm is triggered.
RANDOM SCAN: Dome starts RANDOM scan operation when alarm is triggered.
FRAME SCAN: Dome starts FRAME scan operation when alarm is triggered.
TRACKING: Dome calls preset and start auto tracking. Tracking function only available with the models named NVD18XXPT, NVD22XXPT, NVD23XXPNT and NVD26XXPNT.
(4) Press iris Open to confirm selection.
Set auxiliary to activate:
(1) Move joystick to position the cursor beside ACTIVATE AUX.
(2) Press iris Open.
(3) Move the joystick up or down to view the following available selections.
OFF(default): Not activated.
1: An alarm action will close AUX 1.
2: AN alarm action will close AUX 2.
(4) Press iris Open to confirm selection.
Set alarm contact :
(1) Move joystick to position the cursor beside ALARM CONTACT.
(2) Press iris Open.
(3) Move the joystick up or down to view the following available selections.
OFF(default): close
ON: open.
30 / 39
Bernee Auto Tracking Dome Camera User Manual
(4) Press iris Open to confirm selection.
3.6.3 Aux Setting
Move joystick to select <AUX>, then press Open to enter the aux menu shown as Fig 3.20.
AUX
DWELL TIME<SECS> 1 0
DWELL TIME<SECS> 2 0
BACK
EXIT
FIGURE 3.20 AUX
An auxiliary output is a programmable signal from the dome back box that can trigger another device to operate. An auxiliary output is programmable to trigger from an alarm or from a controller.
An AUX 1 command from the controller will place a ground at the output of AUX 2 to operate the device that is connected to it.
Setting include: 0~30secs.
An AUX 2 command from the controller will place a ground at the output of AUX 2 to operate the device that is connected to it.
Setting include: 0~30secs.
3.6.4 Password Setting
Move joystick to select <PASSWORD>, then press Open to enter the password menu shown as Fig
3.21.
PASSWORED
EBABLE PASSWORD OFF
<EDIT PASSWORD>
BACK
EXIT
Figure 3.21 PASSWORED
This setting protects it from unauthorized changes to the dome settings.
ENABLE PASSWORD:
Open or close the password features.
EDIT PASSWORD(Four Numbers):
31 / 39
Bernee Auto Tracking Dome Camera User Manual
PLEASE INPUT OLD PASSWORED
PASSWORD
1 2 3 4 5 6 7 8 9 0
CLEAR
ENTER
EXIT
Figure 3.22 EDIT PASSWORD
(1) Move joystick to position the cursor beside a number. Press iris Open to confirm selection.
(2) When password is inputted, move the cursor to ENTER and press iris Open comes to the
PLEASE INPUT NEW PASSWORED.
(3) Input four new passwords, move the cursor to ENTER then press iris Open and comes to
PLEASE INPUT NEW PASSWORED. Input four new passwords.
3.6.5 Windows Blanking
Move joystick to select <WINDOWS BLANKING>, then press Open to enter the windows blanking menu shown as Fig 3.23.
WINDOWS BLANKING
STYLE GRAY
BLANK ALL ABOVE OFF
BALANK ALL BELOW OFF
<SET WINDOWS>
BACK
EXIT
Figure 3.22 WINDOWS BLANKING
Window blanking enables you to program up to eight, four-sided, user-defined areas that cannot be viewed by the operator of the dome system. A blanked area will move with pan and tilt functions and automatically adjust in size according to zoom times.
Style:
The dome has two styles for window blanking, GRAY and SMEAR. If style is set to gray, the blanked area is covered with a solid gray window. If smear is selected images behind the window will be noticeable but not distinguishable.
BLANK ALL ABOVE/BLANK ALL BELOW:
The dome camera has two style modes for window blanking, GRAY and SMEAR. If style is set to gray, the blanked area is covered with a solid gray window. If smear is selected images behind the window will be noticeable but not distinguishable.
Blanking Parameters:
32 / 39
Bernee Auto Tracking Dome Camera User Manual
OFF
BLANK ALL ABOVE
No Blanking OFF
BLANK ALL BELOW
No Blanking
0 -5º~10º 0 5º~92º
-5º~92º
20 -5º~35º 20 5º~92º
30 -5º~45º 30 15º~92º
40 -5º~55º 40 25º~92º
50 -5º~65º 50 35º~92º
60 -5º~75º 60 45º~92º
70 -5º~85º 70 55º~92º
80 -5º~95º 80 70º~92º
3.6.6 Set Windows
Move joystick to select <SET WINDOWS>, then press Open to enter the set windows menu shown as Fig 3.24.
SET WINDOWS
WINDOWS NUMBER 1
<EDIT WINDOWS LOCATION>
<EDIT WINDOW ZOOM >
ENABLE WINDOWS OFF
CLEAR WINDOWS
BACK
EXIT
Figure 3.24 SET WINDOWS MENU
Windows Number: 1 ~ 8.
<Edit windows location>: Edit the location of windows blanking
<Edit window zoom>: set the zoom of the blanking. The blanking will take effect when the video is zoomed to this time or above.
Enable Windows: Enable or disable the current blanking
Clear windows: clear the current windows blanking
Operation:
1. Move joystick to select a item
2. Press iris Open
3. Move joystick to select parameters
33 / 39
Bernee Auto Tracking Dome Camera User Manual
3.6.7 Edit Windows Location
Move joystick and move cursor to < EDIT WINDOWS LOCATION >, then press open to enter the menu as Fig 3.25.
EDIT WINDOWS LOCATION
IRIS OPEN TO CONTINUE
IRIS CLOSE TO CANCEL
Figure 3.25 EDIT WINDOWS MENU
Operation:
1. From Fig 3.25, move cursor to make sure it is at the center points of blanking and coordinate.
2. From the menu of Fig. 3.25, press Close to return to the menu of Fig 3.24
3. From the menu of Fig. 3.25, press Open to enter menu of Fig 3.26 to edit the windows location.
EDIT WINDOW LOCATION
Figure 3.26 EDIT WINDOW LOCATION
4. From the EDIT WINDOW LOCATION menu shown in Fig 3.26:
Move joystick left; zoom in (left/right) from the zone center.
Move stick right; zoom in (left/right) from the zone center.
Move stick up; zoom in (up/down) from the zone center.
Move stick down; zoom in (up/down) from the zone center.
5. After the zone is set, press Open to save the settings and return to menu of Figure3.24.
3.6.8 Edit Windows Zoom
From the menu of Figure 3.24, move stick and move cursor to <Edit Window Zoom>, press Open to enter below menu:
EDIT WINDOWS
IRIS OPEN TO CONTINUE
IRIS CLOSE TO CANCEL
Figure 3.27 EDIT WINDOWS
Pan the joystick to adjust the zoom times.
34 / 39
Bernee Auto Tracking Dome Camera User Manual
Press Close to discard the setting and return to Fig 3.24
Press Open to save the setting and return to Fig 3.24.
3.6.9 Heater Setting
From the dome setting 2 menus shown in Fig3.17, move joystick and move cursor to HEATER
SETTING, press Open to enter the following menu (Figure 3.28).
HEATER SETTING
HEATER DISPLAY ON
HEATER MODE AUTO
TEMPERATUEE SET 33℃
BACK
EXIT
Figure 3.28 HEATER SETTING
HEATER DISPLAY:
Heater display shows heater state.
ON: Screen will display heater state.
OFF: Screen will not display heater state.
HEATER MODE:
Heater mode is to set the heater’s startup mode.
AUTO: Heater starts when temperature is lower than lower temperature.
OFF: Heater is closed.
ON: Heater is open.
TEMPERATURE SET:
Temperature set is to set the heater’s startup temperature.
Operations:
1. Move joystick to select an item.
3. Move the stick to select a parameter.
3.6.10 Cruise Setting
From the menu shown in Fig3.17, move joystick to select <CRUISE SETTING>, press Open to
35 / 39
Bernee Auto Tracking Dome Camera User Manual enter the following menu.
CRUISE
DWELL TIME<SECS> 7
PRESET LIST 1
1 ON 0 OFF
1 2 3 4 5 6 7 8 9 0
0 1 1 0 0 1 0 1 1 1
BACK
EXIT
Fig 3.29 CRUISE
Dwell Time: the lasting time of preset, from 5~250 seconds
Preset List: parameter 1, 2, 3
Operations:
1. In the menu, move the joystick to select a specific item.
3. Select the parameter with the joystick.
1 ON 0 OFF: Note, they are not changeable,
1234567890: display info, not changeable. When the preset list is 1, “1, 2, 3, 4, 5, 6, 7, 8, 9, 0” indicates presets from 1 ~ 10. When it is 2, it indicates presets from 11 ~ 20. When it is 3, it indicates presets from 21 ~ 30.
0 0 0 0 0 1 0 1 0 1: select the cruising presets. 1 for cruising, 0 for not cruising.
Operations:
1.From the menu in Fig3.21, select relative item of “1234567890” with the joystick.
2. Press Open and select a specific parameter.
Select options with joystick.
3.6.11 Tracking Setting
Move joystick to select <TRACKING SETTING>, press Open to enter the tracking menu shown as
Fig 3.30.
36 / 39
Bernee Auto Tracking Dome Camera User Manual
TRACKING SETTING
DEFAULT SETTING
SIZE SNS MIDIUM
GRAY SNS MIDIUM
LOST ACT TO HOME & TRACKING
AUTO ZOOMING ON
WAIT TINE<S> 40
<TRACKING BOUNDARY>
BACK
EXIT
Figure 3.30 TRACKING SETTING
Default Setting: tracking setting to default.
Size SNS: the size of the target in the screen, Medium, Large, and Small are selectable
GRAY SNS: the sensitivity of the moving object, Medium, High and Low are selectable
LOST AC: the action when the moving object is lost. Parameters include: return home and tracking, keep tracking, stop tracking
AUTO ZOOMING: The dome will auto zoom in / out according to the size and distance of the object.
Parameters can be ON/OFF.
WAIT TIME <S>: When the tracking object is lost, the interval of time for the dome to wait before
Lost Action. Parameters can be 5, 10, 15, 20, 25, 30, 35, 40 seconds.
<TRACKING BOUNDARY>: to set the valid area of tracking function (UP/DOWN/LEFT/RIGHT).
Operations:
1. In the menu of Fig 3.30, move joystick to a specific item
3. Move joystick to select desired parameter
3.6.12 Tracking Boundary
From the menu in Fig3.30, move the cursor to < TRACKING BOUNDRAY >, press Open to enter the following menu (Figure 3.31)
37 / 39
Bernee Auto Tracking Dome Camera User Manual
TRACKING BOUNDARY
BOUNDARY LIMIT OFF
CLEAR BOUNDARY
LEFT LIMIT OFF
RIGHT LIMIT OFF
UP LIMIT OFF
DOWN LIMIT OFF
BACK
EXIT
Figure 3.31 TRACKING BOUNDARY
BOUNDAR LIMIT: enable / disable the boundary
CLEAR BOUNDARY: clear setting of the current boundary
LEFT LIMT: set the left tracking boundary
RIGHT LIMT: set the right tracking boundary
UP LIMT: set the up tracking boundary
DOWN LIMT: set the down tracking boundary
Operations:
1. Move the cursor to a specific function item
3. Move the joystick to select parameter or operate as per screen instructions
3.7 Dome Label
From the menu shown in Fig3.1, move the cursor to <DOME LABEL>, press Open to enter the following menu (Figure .32)
DOME LABLE
<EDIT DOME LABEL>
<CLEAR DOME LABEL>
BACK
EXIT
Figure 3.32 DOME LABLE
<EDIT DOME LABEL>: To edit the dome description and information. Please refer to 3.5.4 Edit
Preset Label”.
<CLEAR DOME LABLE>: Clear current dome label. Press Open to enter the menu and then operate with instructions.
38 / 39
Bernee Auto Tracking Dome Camera User Manual
3.8 Other Functions
RESET CAMERA:
If the camera does not operate or if you close camera’s control, cycle camera power. Cycling camera power resets the camera but does not change any saved camera settings.
REBOOT SYSTEM:
Reboot the system if it does not operate or if there is no control. Rebooting the system will cycle dome and camera power without changing programmed dome settings.
39 / 39
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement