EKSWW150V3 | User manual | Altherma 2
Add to my manualsadvertisement
technical data
EEDEN08-720
ERHQ006-008AD
EKHBH/X008AA
ERHQ011-016AA
EKHBH/X016AB
EKHWS(U)
EKSOL
Altherma
ERHQ006-008AD
EKHBH/X008AA
ERHQ011-016AA
EKHBH/X016AB
EKHWS(U)
EKSOL
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
Daikin Europe N.V. is approved by LRQA for its
Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
Daikin units comply with the European regulations that guarantee the safety of the product.
“The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin
Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V.
explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe
N.V..”
Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Ostend, Belgium www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende
EEDEN0 8 - 7 2 0
technical data
EEDEN08-720
ERHQ006-008AD
EKHBH/X008AA
ERHQ011-016AA
EKHBH/X016AB
EKHWS(U)
EKSOL
r r A e e 0 h h 1 t t 4 l l A A R
• • R-410A • ALTHERMA
4
Heating only
Heat pump
• Altherma •
technical data
EEDEN08-720
Part 1/3:
ERHQ006-008AD
EKHBH/X008AA
• Outdoor units • R-410A • ERHQ006-008AD
TABLE OF CONTENTS
ERHQ006-008AD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Nominal Capacity and Nominal Input
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dimensional drawing & centre of gravity
. . . . . . . . . . . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
• Altherma • Outdoor units 7
• Outdoor units • R-410A • ERHQ006-008AD
1 Features
D A 8 n 0 u 0 a 6 m o A 0 o 0 e 0 1 Q h d 4 H R u R E A O • Cost effective alternative to a fossil fuel boiler
• Low energy bills and low CO2 emissions 1
1
• Easy to install
• Total solution for year round comfort
8 • Altherma • Outdoor units
2
• Outdoor units • R-410A • ERHQ006-008AD
Specifications
2-1 NOMINAL CAPACITY AND NOMINAL INPUT
Indoor Units
Condition 1
Condition 2
Notes
Notes
Heating capacity
Heating PI
COP
Heating
Heating PI
COP
ERHQ006AD ERHQ007AD ERHQ008AD
Minimum
Nominal
Maximum
Nominal
Nominal
Minimum
Nominal
Maximum
Nominal
Nominal kW kW kW kW kW kW kW kW
EKHBH008AA
4.36
5.75
7.45
1.26
4.56
3.87
5.03
6.68
1.58
3.18
EKHBH008AA
4.36
6.84
8.79
1.58
4.34
3.87
6.10
7.98
1.95
3.13
Condition 1: cooling Ta 35°C - LWE 18°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 35°C ( DT = 5°C )
EKHBH008AA
4.36
8.43
9.58
2.08
4.05
3.87
7.64
8.76
2.54
3.00
Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
2-1 NOMINAL CAPACITY AND NOMINAL INPUT
Indoor Units
Condition 1 Heating capacity
Minimum kW
Cooling capacity
Nominal
Maximum
Minimum kW kW kW
Condition 2
Notes
Notes
Heating PI
Cooling PI
COP
EER
Heating
Cooling
Heating PI
Cooling PI
COP
EER
ERHQ006AD
EKHBX008AA
4.36
5.75
7.45
4.82
ERHQ007AD
EKHBX008AA
4.36
6.84
8.79
4.82
Nominal
Maximum
Nominal
Nominal
Nominal
Nominal
Minimum
Nominal kW kW kW kW
4.56
3.17
3.87
5.03
7.20
7.20
1.26
2.27
4.34
2.94
3.87
6.10
8.16
8.50
1.58
2.78
Maximum
Minimum
Nominal
Maximum
Nominal
Nominal
Nominal
Nominal kW kW kW kW kW kW kW kW
6.68
3.67
5.12
5.12
1.58
2.16
3.18
2.37
7.98
3.67
5.86
6.13
1.95
2.59
3.13
2.26
Condition 1: cooling Ta 35°C - LWE 18°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 35°C ( DT = 5°C )
Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
ERHQ008AD
EKHBX008AA
4.36
8.43
9.58
4.82
2.54
2.75
3.00
2.21
8.76
3.67
6.08
7.10
4.05
2.82
3.87
7.64
8.37
8.91
2.08
2.97
2-2 TECHNICAL SPECIFICATIONS
Casing
Dimensions
Colour
Material
Unit
Packing
Height
Width
Depth
Height
Width
Depth
Weight
Packing
Unit
Packed Unit
Material
Material
Weight mm mm kg kg mm mm mm mm kg
ERHQ006AD ERHQ007AD
Ivory white
Polyester painted galvanised steel
797
960
390
735
825
300
56
61
EPS
Carton
5
ERHQ008AD
1
2
• Altherma • Outdoor units 9
2
• Outdoor units • R-410A • ERHQ006-008AD
Specifications
1
2
2-2 TECHNICAL SPECIFICATIONS
Heat Exchanger Specifications
Fan
Compressor
Operation
Range
Sound Level
(nominal)
Length
Nr of Rows
Fin Pitch
Nr of Stages
Tube type
Fin Type
Treatment
Type
Quantity
Motor
Heating
Cooling
Quantity
Output
Quantity
Motor
Heating
Cooling
Max
Min
Max
Sanitary water Min
Model
Type
Motor Output
Min
Max
Sound Power
Sound Pressure
Sound Power
Sound Pressure
Refrigerant Type
Charge
Control
Nr of Circuits
Refrigerant Oil Type
Piping
Connections
Liquid
Gas
Type
Diameter (OD)
Type
Diameter (OD)
Drain Quantity
Type
Diameter (OD)
Minimum Piping Length
Maximum
Additional Refrigerant Charge
Installation height difference
Maximum
Defrost Method
Defrost Control
Capacity Control Method
Standard
Accessories
Item
Quantity
Standard
Accessories
Item
Quantity
Notes
Notes mm mm mm m m kg/m m mm mm
W
W
°CWB
°CWB
°CDB
°CDB
°CDB
°CDB dBA dBA dBA dBA kg
ERHQ006AD
61
48
63
48
ERHQ007AD
845
2
1.8
32
Hi-Xa(8)
WF fin
Anti-corrosion treatment (PE)
Propeller
53
1
1
1
2YC63BXD#C
Hermetically sealed swing compressor
1,920
-20
25
10
43
-20
43
61
48
63
48
R-410A
1.7
Expansion valve(electronic type)
1
FVC50K
Flare connection
6.35
Flare connection
15.9
1
Socket
18
3
30
0.02>10m
20
ERHQ008AD
62
49
63
50
Reverse cycle
Sensor for outdoor heat exchanger temperature
Inverter controlled
Installation manual
1
Drain plug
1
See operation range drawing
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
10 • Altherma • Outdoor units
2
• Outdoor units • R-410A • ERHQ006-008AD
Specifications
2-3 ELECTRICAL SPECIFICATIONS
Power Supply
Current
Wiring
Connections
Name
Phase
Frequency
Voltage
Voltage Range Minimum
Maximum
Starting current Heating
Cooling
Maximum running Current
Heating
Cooling
Minimum S sc value
Recommended fuses
For power supply Quantity
For connection with indoor
Quantity
Remark
A
A
A
A
V
V
Hz
V kVA
A
ERHQ006AD ERHQ007AD
-10%
+10%
11
11
V3
1~
50
230
18
16.25
Equipment complying with EN/IEC 61000-3-12
20
3
4
Included earth wiring
ERHQ008AD
1
2
• Altherma • Outdoor units 11
1
3
• Outdoor units • R-410A • ERHQ006-008AD
3 Dimensional drawing & centre of gravity
3 - 1 Dimensional drawing
ERHQ006-008 AD
Drain outlet
(I.D. J 15.9 hose for connection)
Minimum space for air passage
Wall height on air outlet side
= less than 1200 unit (mm)
4 x holes for anchor bolts (M8 or M10)
Brand name label
Name plate
In case of removing stop valve cover
Wiring inlet
Terminal strip with earth terminal
Outdoor air temperature thermistor
Liquid stop valve
(J6.4 CuT)
Service port
Gas stop valve
(J15.9 CuT) 3D060289
12 • Altherma • Outdoor units
• Outdoor units • R-410A • ERHQ006-008AD
3 Dimensional drawing & centre of gravity
3 - 2 Centre of gravity
ERHQ006-008 AD
1
3
The position of foundation bolt
4D042258L
• Altherma • Outdoor units 13
4
• Outdoor units • R-410A • ERHQ006-008AD
Piping diagram
1
4
ERHQ006-008AD
Outdoor unit
Heat exchanger
Heat exchanger thermistor
Propeller fan
Four way valve on : heating
Muffler
Muffler
Discharge pipe thermistor
Compressor
Outdoor air temperature thermistor
Capillary tube 1
Capillary tube 2
Capillary tube 3
Capillary tube 4
Muffler with filter
Filter
Motor operated valve
Refrigerant flow
Cooling
Heating
Filter
Accumulator
Muffler with filter
Liquid stop valve
Field piping
Field piping
Gas stop valve with service port
3D052750B
14 • Altherma • Outdoor units
• Outdoor units • R-410A • ERHQ006-008AD
5 Wiring diagram
5 - 1 Wiring diagram
ERHQ006-008AD
Power supply
To indoor unit
Indoor g
Field wiring
Sheet metal
Z1C ∼Z7C
X1M, X2M
: Ferrite core
: Terminal strip
Y1E : Electronic expansion valve coil
V2, V3, V5, V9, V100 : Varistor
SA2
FU1, FU2, FU3:
AC1, AC2
U, V, W, X11A, X12A
E1, E2
HR1, HR2
: Surge arrester
: Fuse
: Connector
MRM10, MRM20
MRC/W
R1T ∼R3T
S2
∼S102
LEDA
L
N
SW1
SW4
M1C
M1F
L1R
: Magnetic relay
: Thermistor
: Connector
: Pilot lamp
: Live
: Neutral
: Forced operation on/off switch SW (SW1)
: Local setting SW (SW4)
: Compressor motors
: Fan motor
: Reactor
Outdoor
Q1L
PM1
PCB1,2
Y1R
Sheet metal
(outdoor) (discharge)
(Condenser)
: Overload protector
: Power module
: Printed circuit board
: Reversing solenoide valve coil
: Terminal strip fixed plate
3D052296E
1
5
• Altherma • Outdoor units 15
• Outdoor units • R-410A • ERHQ006-008AD
1
6
6 Sound data
6 - 1 Sound pressure spectrum
ERHQ006AD
Heating
ERHQ007AD
Heating
3TW57557-2
NOTES
Octave band center frequency (Hz)
1 Data is valid at free field condition (measured in a semi-anachoic room)
2 dB(A) = A-weighted sound power level (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Coil
Microphone
Location of microphone
ERHQ008AD
Heating
3TW57557-2
NOTES
Octave band center frequency (Hz)
1 Data is valid at free field condition (measured in a semi-anachoic room)
2 dB(A) = A-weighted sound power level (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Coil
Microphone
Location of microphone
ERHQ006AD
Cooling
16
3TW57557-2
NOTES
Octave band center frequency (Hz)
1 Data is valid at free field condition (measured in a semi-anachoic room)
2 dB(A) = A-weighted sound power level (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Coil
Microphone
Location of microphone
• Altherma • Outdoor units
3TW57557-1
NOTES
Octave band center frequency (Hz)
1 Data is valid at free field condition (measured in a semi-anachoic room)
2 dB(A) = A-weighted sound power level (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Coil
Microphone
Location of microphone
• Outdoor units • R-410A • ERHQ006-008AD
6 Sound data
6 - 1 Sound pressure spectrum
ERHQ007AD
Cooling
ERHQ008AD
Cooling 1
6
3TW57557-1
NOTES
Octave band center frequency (Hz)
1 Data is valid at free field condition (measured in a semi-anachoic room)
2 dB(A) = A-weighted sound power level (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Coil
Microphone
Location of microphone
3TW57557-1
NOTES
Octave band center frequency (Hz)
1 Data is valid at free field condition (measured in a semi-anachoic room)
2 dB(A) = A-weighted sound power level (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
Coil
Microphone
Location of microphone
• Altherma • Outdoor units 17
• Indoor units • R-410A • EKHBH(X)008AA
TABLE OF CONTENTS
EKHBH(X)008AA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Dimensional drawing & centre of gravity
. . . . . . . . . . . . . . . . . . . . . . . 27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
• Altherma • Indoor units 19
• Indoor units • R-410A • EKHBH(X)008AA
1 Features
A A T 8 0 N 0 U a X m R A O H e 0 1 B h O H D 4 K N E A R • Cost effective alternative to a fossil fuel boiler
• Low energy bills and low CO2 emissions 1
1
• Easy to install
• Total solution for year round comfort
20 • Altherma • Indoor units
2
• Indoor units • R-410A • EKHBH(X)008AA
Specifications
2-1 TECHNICAL SPECIFICATIONS
Outdoor units
Nominal input
(Indoor only)
Casing
W
Dimensions
Colour
Material
Packing
Unit
Height
Width
Depth
Height(1)
Width
Depth
Weight
Packing
Machine weight
Gross
Weight
Material
Material
Material
Material
Weight
Main components Pump
Water circuit kg
Water side
Heat exchanger kg
Type
Nr. of speed
Nominal
ESP unit
Heating
Cooling kPa kPa
W Power input
Type
Qty
Water volume
Water flow rate Min.
Water flow rate No l l/min
Heating (3) l/min
Cooling (2) l/min
Expansion vessel
Insulation material
Volume
Max. water pressure
Pre pressure
Water filter Diameter perforations
Material
Piping connections diameter (7)
Piping l bar bar mm inch inch bar
Air purge valve
Total water volume (6)
Refrigerant Circuit Gas side diameter
Liquid side diameter
Sound Level Sound Pressure (4)
Sound Power (8)
Operation range
Safety valve
Manometer
Drain valve / Fill valve
Shut off valve
Ambient Heating
Cooling
Waterside Heating (5)
Cooling mm mm mm mm mm mm kg dBA
°C
°C
°C
°C l mm mm dBA
Outdoor units
Nominal input (Indoor only)
Casing Colour
Material
W
EKHBH008AA EKHBX008AA
ERHQ006AD
230
RAL9010
Epoxy polyester painted galvanised steel
1225
660
610
922
502
361
50
65
EPS
Wood
Carton
PP (straps)
10
Water cooled
3
49 49
51
130
Brazed plate
1
0.67
12
16.5
16.5
14.7
Polyurethane foam
10
3
1
1
Brass
G 1 (MALE)
1-1/4"
Yes
5.5
15.9
6.35
3
Yes
Yes
Yes
28
42
-20~25
15~50
ERHQ007AD
230
RAL9010
Epoxy polyester painted galvanised steel
-20~25
10~43
15~50
5~22
• Altherma • Indoor units
1
2
21
2
• Indoor units • R-410A • EKHBH(X)008AA
Specifications
1
2
2-1 TECHNICAL SPECIFICATIONS
Dimensions
Weight
Packing
Unit
Height
Width
Depth
Height(1)
Machine weight
Gross Weight
Width
Depth
Packing Material
Material
Material
Material
Weight
Main components Pump
Water side
Heat exchanger kg
Type
Nr. of speed
Nominal ESP unit
Heating
Cooling kPa kPa
W Power input
Type
Qty
Water volume
Water flow rate Min.
Water flow rate Nom.
l l/min
Heating (3) l/min
Cooling (2) l/min mm mm kg kg mm mm mm mm
Water circuit
Expansion vessel
Insulation material
Volume
Max. water pressure
Pre pressure
Water filter Diameter perforations
Material
Piping connections diameter (7)
Piping
Safety valve
Manometer
Drain valve / Fill valve
Shut off valve
Air purge valve
Total water volume (6)
Refrigerant Circuit Gas side diameter
Liquid side diameter
Sound Level Sound Pressure (4)
Sound Power (8) l bar bar mm inch inch bar dBA
°C
°C
°C
°C l mm mm dBA
Operation range Ambient Heating
Cooling
Waterside Heating (5)
Cooling
Outdoor units
Nominal input (Indoor only)
Casing Colour
Material
Dimensions Packing
Unit
Height
Width
Depth
Height(1)
Width
Depth
W mm mm mm mm mm mm
EKHBH008AA EKHBX008AA
502
361
50
65
1225
660
610
922
EPS
Wood
Carton
PP (straps)
10
Water cooled
3
45 45
49
130
Brazed plate
1
0.67
12
19.6
19.6
16.8
Polyurethane foam
10
3
1
1
Brass
G 1 (MALE)
1-1/4"
Yes
5.5
15.9
6.35
3
Yes
Yes
Yes
28
42
-20~25
15~50
ERHQ008AD
230
RAL9010
Epoxy polyester painted galvanised steel
-20~25
10~43
15~50
5~22
1225
660
610
922
502
361
22 • Altherma • Indoor units
2
• Indoor units • R-410A • EKHBH(X)008AA
Specifications
2-1 TECHNICAL SPECIFICATIONS
Weight
Packing
Machine weight
Gross Weight
Material
Material
Material
Material
Weight
Main components Pump
Water side
Heat exchanger kg kg kg
Type
Nr. of speed
Nominal
ESP unit
Heating
Cooling kPa kPa
W Power input
Type
Qty
Water volume
Water flow rate Min.
Water flow rate Nom.
l l/min
Heating (3) l/min
Cooling (2) l/min
Water circuit
Expansion vessel
Insulation material
Volume
Max. water pressure
Pre pressure
Water filter Diameter perforations
Material
Piping connections diameter (7)
Piping l bar bar mm inch inch bar Safety valve
Manometer
Drain valve / Fill valve
Shut off valve
Air purge valve
Total water volume (6)
Refrigerant Circuit Gas side diameter
Liquid side diameter
Sound Level Sound Pressure (4)
Sound Power (8)
Operation range Ambient
Waterside
Heating
Cooling
Heating (5)
Cooling dBA
°C
°C
°C
°C l mm mm dBA
Notes
Notes
Notes
Notes
Notes
Notes
Notes
Notes
EKHBH008AA EKHBX008AA
50
65
EPS
Wood
Carton
PP (straps)
10
Water cooled
3
38 38
48
130
Brazed plate
1
0.67
12
24.1
24.1
17.4
Polyurethane foam
10
3
1
1
Brass
G 1 (MALE)
1-1/4"
Yes
5.5
15.9
6.35
3
Yes
Yes
Yes
28
42
-20~25
15~50
-20~25
10~43
15~50
5~22
(1) With option kit EKHBDP installed: Height=936mm
(2) Tamb 35°C - LWE 7°C (DT=5°C)
(3) DB/WB 7°C/6°C-LWC 35°C(DT=5°C)
(4) The sound pressure level is measured via a microphone at 1m from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is valid for pump medium speed.
(5) 15°C-25°C: BUH only, no Heatpump operation=during commissioning.
(6) Including piping+PHE+backup heater/excluding expansion vessel.
(7) Value mentioned is connection after ball valves. Connection at unit is G1 1/2 female
(8) DB/WB 7°C/6°C-LWC 35°C(DT=5°C), medium pump speed
1
2
• Altherma • Indoor units 23
2
• Indoor units • R-410A • EKHBH(X)008AA
Specifications
1
2
2-2 ELECTRICAL SPECIFICATIONS
Electric heater Type
Power
Supply
Current
Voltage
Range
Wiring
Connections
Phase
Frequency
Voltage
Running Current
Minimum
Maximum
For power supply backup heater
Quantity of wires
Type of wires
Hz
V
A
Electric heater Type
Power
Supply
Current
Voltage
Range
Wiring
Connections
Phase
Frequency
Voltage
Running Current
Minimum
Maximum
For power supply backup heater
Quantity of wires
Type of wires
Hz
V
A
Electric heater Type
Power
Supply
Current
Voltage
Range
Wiring
Connections
Phase
Frequency
Voltage
Running Current
Minimum
Maximum
For power supply backup heater
Quantity of wires
Type of wires
Hz
V
A
Electric heater Type
Power
Supply
Current
Voltage
Range
Wiring
Connections
Phase
Frequency
Voltage
Running Current
Minimum
Maximum
For power supply backup heater
Quantity of wires
Type of wires
Hz
V
A
Electric heater Type
Power
Supply
Current
Voltage
Range
Maximum
Wiring
Connections
Phase
Frequency
Voltage
Running Current
Minimum
For power supply backup heater
Quantity of wires
Type of wires
Hz
V
A
EKHBH008AA EKHBX008AA
3V3
1~
50
230
13
-10%
+10%
3G
Select diameter and type according to national and local regulations
6V3
1~
50
230
26
-10%
+10%
3G
Select diameter and type according to national and local regulations
6WN
3~
50
400
8.7
-10%
+10%
4G
Select diameter and type according to national and local regulations
6T1
3~
50
230
15.1
-10%
+10%
4G
Select diameter and type according to national and local regulations
9WN
3~
50
400
13
-10%
+10%
4G
Select diameter and type according to national and local regulations
24 • Altherma • Indoor units
2
• Indoor units • R-410A • EKHBH(X)008AA
Specifications
2-2 ELECTRICAL SPECIFICATIONS
Electric heater Type
Power
Supply
Current
Voltage
Range
Wiring
Connections
Wiring Connections Connection type
Quantity of wires
Type of wires
Phase
Frequency
Voltage
Running Current
Minimum
Maximum
For power supply backup heater
Quantity of wires
Type of wires
Hz
V
A
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
EKHBH008AA EKHBX008AA
9T1
3~
50
230
22.6
-10%
+10%
4G
Select diameter and type according to national and local regulations
For power supply connection to Optional Warm Water Tank + Q2L
3G
Select diameter and type according to national and local regulations
For more details of the voltage range and current refer to installation manual EKHBH/
X008AA*
For connection with R5T
Wire included in option EKHWS*
Wire included in option EKHWS*
For connection with A3P
Depends on thermostat type, refer to installation manual EKHBH/X008AA*
Select diameter and type according to national and local regulations
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
For connection with M2S
3G
Select diameter and type according to national and local regulations
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
For connection with M3S
3G or 4G
Select diameter and type according to national and local regulations
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
1
2
• Altherma • Indoor units 25
• Indoor units • R-410A • EKHBH(X)008AA
3 Options
1
3
Factory mounted optional equipment for EKHB(H/X)008AA**
3V3
6V3
6W1
6T1
9W1
9T1
Reference Description
Heating only model EKHBH008A...
Reversible model EKHBX008A...
Back up heater 3kW 1 ∼230 V
Back up heater 6kW 1 ∼230 V
Back up heater 6kW 3 ∼400 V
Back up heater 6kW 3 ∼230 V
Back up heater 9kW 3 ∼400 V
Back up heater 9kW 3 ∼230 V
Outdoor combination table for EKHB(H/X)008AA**
A3V3
A3V3
A6V3
A6V3
A6V3
A6WN
A6T1
A6T1
A9WN
A9WN
A9T1
A9T1
V V
⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯
⎯ ⎯
V V
⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯
⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯ ⎯ ⎯ ⎯ ⎯
⎯ ⎯ ⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯ ⎯ ⎯
⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯
⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯
V V
EKHBH008AA*
EKHBX008AA*
Kit availability for ERHQ006AD*
Heating only indoor unit
Reversible indoor unit
ERHQ006ADV3 ERHQ007ADV3 ERHQ008ADV3
V
V
V
V
V
V
EKBPHT16
Kit availability for EKHB(H/X)008AA*
Bottom plate heater (1)
Reference
EKHWS150A3V3
EKHWS200A3V3
EKHWS300A3V3
EKHWS200A3Z2
EKHWS300A3Z2
EKHWSU150A3V3
EKHWSU200A3V3
EKHWSU300A3V3
EKHBDP
EKRP1HB
(*) If neutral line is available
Kit available for EKHWS*
ERHQ006ADV3 ERHQ007ADV3 ERHQ008ADV3
V V V
Description
Heating only model EKHBH008A...
Reversible model EKHBX008A...
Domestic hot water tank 150l 1-230V
Domestic hot water tank 200l 1-230V
Domestic hot water tank 300l 1-230V
Domestic hot water tank 200l 2-400V
Domestic hot water tank 300l 2-400V
Domestic hot water tank 150l 1-230V
Domestic hot water tank 200l 1-230V
Domestic hot water tank 300l 1-230V
Option kit for condensate free cooling operation
Digital I/O PCB (2)
A3V3 A6V3 A6WN A6T1 A9WN A9T1
A3V3 A6V3 A6WN A6T1 A9WN A9T1
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯
V V
⎯ ⎯
⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯
V V
⎯ ⎯
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
⎯
V
⎯
V
⎯
V
⎯
V
⎯
V
⎯
V
V V V V V V V V V V V V
Reference
EKUHWA
EKSOLHWAV1
EKWBSWW150
Description
EKHWS...
EKHWSU...
Option kit for UK EKHWSU150-300V3
Solarkit (3)
Wall bracket for EKSWW150V3
15A3V3 200A3V3/Z2 300A3V3/Z2
⎯
V
V
⎯
V
⎯
⎯
V
⎯
150A3V3 200A3V3 300A3V3
V V V
V
V
V
⎯
V
⎯
Remarks: Other combinations than mentioned in this option TW are not guaranteed.
(1) Heater tape that can be fixed on the bottom plate to prevent ice formation.
(2) Address card that provides two additional output connections (remote alarm and remote ON/OFF signalisation). In EKSOLHWAV1, the same digital I/O
PCB as for EKRP1HB is already included.
(3) Kit to be mounted on domestic hot water tank that provides connection to solar panels for additional water heating.
3TW57789-2C
26 • Altherma • Indoor units
• Indoor units • R-410A • EKHBH(X)008AA
4 Dimensional drawing & centre of gravity
4 - 1 Dimensional drawing
EKHBH008AA
FIXATION
Dimensions wallbracket
Minimum space for service & ventilation
Min. 200
Center of gravity
Pump + switch for speed setting
Remocon
Water IN connection G 1 1/2 (female)
Water OUT connection G 1 1/2 (female)
Power supply intake (+ domestic hot water tank)
Air purge
Expansion vessel+j nipple+j Drain
Blow off valve
Blow off drain (flexible hose J20)
Pressure gauge
Water filter
Suction pipe connection J15.9 flare connection
Liquid pipe connection J6.35 flare connection
Shut off valves with drain/fill valve (accessory delivered with unit)
Holes for fixation
Switchbox terminals
Switchbox terminals option domestic hot water tank
Wallbracket
EKHBX008AA
FIXATION
G 1 (Male)
Service door
(Closed) 361
(Open) 553
3TW57784-1A
1
4
Dimensions wallbracket
Minimum space for service & ventilation
Min. 200
Center of gravity
Pump + switch for speed setting
Remocon
Water IN connection G 1 1/2 (female)
Water OUT connection G 1 1/2 (female)
Power supply intake (+ domestic hot water tank)
Air purge
Expansion vessel+j nipple+j Drain
Blow off valve
Blow off drain (flexible hose J20)
Pressure gauge
Water filter
Suction pipe connection J15.9 flare connection
Liquid pipe connection J6.35 flare connection
Shut off valves with drain/fill valve (accessory delivered with unit)
Holes for fixation
Switchbox terminals
Switchbox terminals option domestic hot water tank
Wallbracket
G 1 (Male)
Service door
(Closed) 361
(Open) 553
3TW57784-2A
• Altherma • Indoor units 27
5
• Indoor units • R-410A • EKHBH(X)008AA
Piping diagram
1
5
EKHBH(X)008AA
R4T Inlet water thermistor
R3T Refrigerant liquid side thermistor
R2T Outlet water backup heater thermistor
R1T Outlet water heat-exchanger thermistor
Water side
Filter
Refrigerant side
Pressure gauge Drain valve
Safety valve
Drain
Field installation
Shut off valve
Inlet
Expansion vessel
Cooling (EKHBX)
Heating (EKHBX + EKHBH)
Drain valve
Option backup heater
Pump
Air purge
Overview
Electric heater body
Refr. out
Refr. in
Refr. in
Refr. out
Refrigerant side
Evaporator
Condensor
Water side
Water inlet
Water outlet
O
Check valve
L
Flare connection
M
Screw connection
N
Flange connection
Z
Pinched pipe
P
Spinned pipe
Flowswitch
Field installation
Shut off valve
Outlet
3TW56715-1
28 • Altherma • Indoor units
• Indoor units • R-410A • EKHBH(X)008AA
6 Wiring diagram
6 - 1 Wiring diagram
EKHBH(X)008AA3V3
Power supply
230V 1N ∼50Hz
>> See note 2 <<
Outdoor unit
Only for EKSOLHWAV1
Option
Solar pump connection
See note 9
Domestic hot water tank
Only for EKHW*V3 Option
See note 7
For EKHWSU*V3
Option
1
6
User interface
Domestic hot water tank
Only forEKHW*V3
Option
See note 7
For EKHWSU*V3 Option
Wiring dependent on model
Field wiring
EKHBH(X)008AA6V3
Power supply
230V 1N ∼50Hz
>> See note 2 <<
Only for EKRP1HB
Option
See note 8
Option
Field wiring
PCB
Wire colour
NO valve
Spring return type
230V AC supply from
PCB
Only for EKSWW option
F1B
Electric heater option fuse
20A
Thermostat
On/Off
NC valve
3 wire type
(SPST)
Notes:
1 This wiring diagram only applies to the indoor unit.
2 Use one and same dedicated power supply for indoor ubit, outdoor unit and EKHW option.
F2B
EKHW kit fuse
20A
3
4
:Field wiring No/No normal open/normal closed SPST - single pole single throw.
:Terminal strip :Connector :Terminal :Protective earth
5 Do not operate the unit by short-sircuiting any protection device.
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet
7 For EKHWSU*V3, refer to option manual
8 Option PCB works with an external 230V AC power supply unit.
9 For EKSOLHWAV1, refer to option manual
Only for EKHW*V3
Option
Outdoor unit
Only for EKSOLHWAV1
Option
Solar pump connection
See note 9
Domestic hot water tank
Only for EKHW*V3 Option
See note 7
For EKHWSU*V3
Option
Only for EKHW Option
K7M
K3M
K1M
F2B
F1B
F1T
A4P
A3P
A2P
A1P
R1T
S1L
E4H
E1H
M3S
M2S
M1P
PHC1
K5M
Q1L
S1S
SS1
TR1
R5T
R4T
R3T
R2T
X1M-X4M
V2S
V1S
FU1
FU2
FuS, FuR
Q1DI
Q2L
: Terminal strips
: Spark suppression 2
: Spark suppression 1
: Fuse 3.15A T 250V
: Fuse 5A T 250V
: Fuse 5A 250V for solar/remote alarm PCB
: Earth leakage protector
: Thermal protector booster heater
: Thermal protector backup heater
: Solar pumpstation relay
: DIP switch
: Transformer 24V for PCB
: Domestic hot water thermistor
: Inlet water thermistor
: Refrigerant liquid side thermistor
: Outlet water backup heater thermistor
: Outlet water heat-exchanger thermistor
: Flowswitch
: Booster heater
: Backup heater element 1
: 3way valve: floorheating/domestic hot water
: 2 way valve for cooling mode
: Pump
: Aplocoupler input circuit
: Contactor for backup heater all-pole disconnection
: Relay for solar pump
: Contactor booster heater
: Contactor backup heater Step 1
: Fuse booster heater
: Fuse backup heater
: Thermal fuse Back up heater
: Solar/remote alarm PCB
: Thermostat (PC-power circuit)
: User interface PCB
: Main PCB 3TW57786-2
User interface
Domestic hot water tank
Only forEKHW*V3
Option
See note 7
For EKHWSU*V3 Option
Wiring dependent on model
Field wiring
Option
Field wiring
Only for EKRP1HB
Option
See note 8
230V AC supply from
PCB
NO valve
Spring return type
Thermostat
On/Off NC valve
3 wire type
(SPST)
PCB
Wire colour
Notes:
1 This wiring diagram only applies to the indoor unit.
2 Use one and same dedicated power supply for indoor ubit, outdoor unit and EKHW option.
3 :Field wiring No/No normal open/normal closed SPST - single pole single throw.
4 :Terminal strip :Connector :Terminal :Protective earth
5 Do not operate the unit by short-sircuiting any protection device.
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet
7 For EKHWSU*V3, refer to option manual
8 Option PCB works with an external 230V AC power supply unit.
9 For EKSOLHWAV1, refer to option manual
F1B
Only for EKSWW option
Only for EKHW*V3
Option
Electric heater option fuse
32A
F2B
EKHW kit fuse
20A
Only for EKHW Option
K7M
K4M
K3M
K1M
F2B
F1B
F1T
A4P
A3P
A2P
A1P
R1T
S1L
E4H
E1H
M3S
M2S
M1P
PHC1
K5M
Q1L
S1S
SS1
TR1
R5T
R4T
R3T
R2T
X1M-X4M
V2S
V1S
FU1
FU2
FuS, FuR
Q1DI
Q2L
: Terminal strips
: Spark suppression 2
: Spark suppression 1
: Fuse 3.15A T 250V
: Fuse 5A T 250V
: Fuse 5A 250V for solar/remote alarm PCB
: Earth leakage protector
: Thermal protector booster heater
: Thermal protector backup heater
: Solar pumpstation relay
: DIP switch
: Transformer 24V for PCB
: Domestic hot water thermistor
: Inlet water thermistor
: Refrigerant liquid side thermistor
: Outlet water backup heater thermistor
: Outlet water heat-exchanger thermistor
: Flowswitch
: Booster heater
: Backup heater element 1
: 3way valve: floorheating/domestic hot water
: 2 way valve for cooling mode
: Pump
: Aplocoupler input circuit
: Contactor for backup heater all-pole disconnection
: Relay for solar pump
: Pump Relay
: Contactor booster heater
: Contactor backup heater Step 1
: Fuse booster heater
: Fuse backup heater
: Thermal fuse Back up heater
: Solar/remote alarm PCB
: Thermostat (PC-power circuit)
: User interface PCB
: Main PCB 3TW57786-3
• Altherma • Indoor units 29
• Indoor units • R-410A • EKHBH(X)008AA
1
6
6 Wiring diagram
6 - 1 Wiring diagram
EKHBH(X)008AA6WN/9WN
Power supply
3(/N)-400(/230V) 50Hz
>> See note 2 <<
Outdoor unit
Only for EKSOLHWAV1
Option
Solar pump connection
See note 9
Domestic hot water tank
Only for EKHW*V3 Option
See note 7
For EKHWSU*V3
Option
Domestic hot water tank
Only for EKHW*Z2
Option
User interface
Domestic hot water tank
Domestic hot water tank
Only forEKHW*V3
Option
Only forEKHW*Z2
Option
See note 7
For EKHWSU*V3 Option
Wiring dependent on model
Field wiring
Option
Field wiring
EKHBH(X)008AA6T1/9T1
Power supply
3-230V 50Hz
>> See note 2 <<
Only for EKRP1HB
Option
See note 8
Outdoor unit
PCB
Wire colour
Thermostat
On/Off
230V AC supply from
PCB
NO valve
Spring return type
NC valve
3 wire type
(SPST)
Model
F1B
Only for EKSWW option
Only for EKHW*V3
Option
Electric heater option fuse
6WN
16A
9WN
20A
F2B
EKHW kit fuse
20A
Notes:
1 This wiring diagram only applies to the indoor unit.
2 Use one and same dedicated power supply for indoor ubit, outdoor unit and EKHW option.
3
4
:Field wiring No/No normal open/normal closed SPST - single pole single throw.
:Terminal strip :Connector :Terminal :Protective earth
5 Do not operate the unit by short-sircuiting any protection device.
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet
7 For EKHWSU*V3, refer to option manual
8 Option PCB works with an external 230V AC power supply unit.
9 For EKSOLHWAV1, refer to option manual
Only for EKSOLHWAV1
Option
Solar pump connection
See note 9
Domestic hot water tank
Only for EKHW*V3 Option
See note 7
For EKHWSU*V3
Option
Only for EKHW
Option
X1M-X4M
V2S
V1S
FU1
FU2
FuS, FuR
Q1DI
Q2L
Q1L/Q3L
S1S
SS1
TR1
R5T
R4T
R3T
R2T
R1T
S1L
E4H
E1H-E3H
M3S
M2S
M1P
PHC1
K5M
K7M
K3M
K1M/K2M
F2B
F1B
F1T
A4P
A3P
A2P
A1P
: Terminal strips
: Spark suppression 2
: Spark suppression 1
: Fuse 3.15A T 250V
: Fuse 5A T 250V
: Fuse 5A 250V for solar/remote alarm PCB
: Earth leakage protector
: Thermal protector booster heater
: Thermal protector backup heater
: Solar pumpstation relay
: DIP switch
: Transformer 24V for PCB
: Domestic hot water thermistor
: Inlet water thermistor
: Refrigerant liquid side thermistor
: Outlet water backup heater thermistor
: Outlet water heat-exchanger thermistor
: Flowswitch
: Booster heater
: Backup heater element 1-3
: 3way valve: floorheating/domestic hot water
: 2 way valve for cooling mode
: Pump
: Aplocoupler input circuit
: Contactor for backup heater all-pole disconnection
: Relay for solar pump
: Contactor booster heater
: Contactor backup heater Step 1/2
: Fuse booster heater
: Fuse backup heater
: Thermal fuse Back up heater
: Solar/remote alarm PCB
: Thermostat (PC-power circuit)
: User interface PCB
: Main PCB
3TW57786-4
User interface
30
Domestic hot water tank
Only forEKHW*V3
Option
See note 7
For EKHWSU*V3 Option
Wiring dependent on model
Only for EKRP1HB
Option
See note 8
Thermostat
On/Off
230V AC supply from
PCB
NO valve
Spring return type
Only for EKSWW option
Only for EKHW*V3
Option
Model
F1B
Electric heater option fuse
6T1
20A
9T1
32A
NC valve
3 wire type
(SPST)
F2B
EKSWW kit fuse
20A
Notes:
1 This wiring diagram only applies to the indoor unit.
2 Use one and same dedicated power supply for indoor ubit, outdoor unit and EKHW option.
3
4
:Field wiring No/No normal open/normal closed SPST - single pole single throw.
:Terminal strip :Connector :Terminal :Protective earth
5 Do not operate the unit by short-sircuiting any protection device.
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet
7 For EKHWSU*V3, refer to option manual
8 Option PCB works with an external 230V AC power supply unit.
9 For EKSOLHWAV1, refer to option manual
Only for EKHW
Option
Q1L
S1S
SS1
R5T
R4T
R3T
R2T
R1T
X1M-X4M
V2S
V1S
FU1
FU2
FuS, FuR
Q1DI
Q2L/Q3L
S1L
E4H
E1H-E3H
M3S
M2S
M1P
PHC1
K5M
K7M
K3M
K1M/K2M
F2B
F1B
F1T
A4P
A3P
A2P
A1P
: Terminal strips
: Spark suppression 2
: Spark suppression 1
: Fuse 3.15A T 250V
: Fuse 5A T 250V
: Fuse 5A 250V for solar/remote alarm PCB
: Earth leakage protector
: Thermal protector booster heater
: Thermal protector backup heater
: Solar pumpstation relay
: DIP switch
: Domestic hot water thermistor
: Inlet water thermistor
: Refrigerant liquid side thermistor
: Outlet water backup heater thermistor
: Outlet water heat-exchanger thermistor
: Flowswitch
: Booster heater
: Backup heater element 1
: 3way valve: floorheating/domestic hot water
: 2 way valve for cooling mode
: Pump
: Aplocoupler input circuit
: Contactor for backup heater all-pole disconnection
: Relay for solar pump
: Contactor booster heater
: Contactor backup heater Step 1
: Fuse booster heater
: Fuse backup heater
: Thermal fuse Back up heater
: Solar/remote alarm PCB
: Thermostat (PC-power circuit)
: User interface PCB
: Main PCB
3TW57786-6
• Altherma • Indoor units
• Indoor units • R-410A • EKHBH(X)008AA
6 Wiring diagram
6 - 2 External connection diagram
Power supply
Unit power supply: 230V + earth
Backup heater power supply (3/6/9kW): 400V or 230V + earth
Optional power supply
Booster heater power supply (3kW): 400V or 230V + earth
Optional parts
3 core
Standard parts
Outdoor unit
X1M:L-N-Earth
X2M:1-2-3-Earth
4 core
X1M:9-10-11-Earth
Sanitary tank
2 way valve
2 core
Q3L - Q1T
Clixon
Thermostat
2 way valve
Power supply booster heater
Q2L - Clixon booster heater
5 core
230V or400V
Only for EKSWWU*V3
X1M:7-8-Earth
NO valve:
NC valve:
R5T - Thermistor water temperature
2 core
Signal
Thermistor cable
Note: min. distance to power cable = 3cm
Indoor unit
User interface
For more details please check unit wiring diagram
Field supply
4 core
2 core
2 core
Room thermostat
A3P (optional)
2 way valve
M2S (EKHBX Units) for cooling mode
3 way valve
M3S (when EKSWW is installed) selection sanitary-floorheating
3TW56719-6A
1
6
• Altherma • Indoor units 31
7
• Indoor units • R-410A • EKHBH(X)008AA
Operation range
Outdoor temp. (°CDB)
1
7
EKHBH(X)008AA
ERHQ006-008AD
Outdoor temp. (°CDB)
Leaving evaporator water temperature (°C)
: Units with optional back up heater
Outdoor temp. (°CDB)
50
Leaving condenser water temperature (°C)
: Booster heater operation only
: Units with optional back up heater or booster heater operation only
Water temperature sanitary tank (°C)
4TW57553-1A
• Altherma • Indoor units 32
• Indoor units • R-410A • EKHBH(X)008AA
8 Hydraulic performance
8 - 1 Static pressure drop unit
EKHBH(X)008AA 1
8
III: High speed
II: medium speed
I: Low speed
ESP: External static pressure
Flow: waterflow through the unit
Warning:
1. Selecting a flow outside the curves can cause damage to or malfunction of the unit. See also minimum and maximum allowed water flowrange in the technical specifications.
2. Water quality must be according to EN directive EC
98/83 EC.
Flow (l/min)
• Altherma • Indoor units
4TW57789-1
33
technical data
EEDEN08-720
Part 2/3:
ERHQ011-016AA
EKHBH/X016AB
• Outdoor units • R-410A • ERHQ011-016AA
TABLE OF CONTENTS
ERHQ011-016AA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Nominal Capacity and Nominal Input
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Dimensional drawing & centre of gravity
. . . . . . . . . . . . . . . . . . . . . . . 44
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
• Altherma • Outdoor units 37
• Outdoor units • R-410A • ERHQ011-016AA
1 Features
A A 6 n 1 u 0 a 1 m o A 1 o 0 e 0 1 Q h d 4 H R u R E A O • Cost effective alternative to a fossil fuel boiler
• Low energy bills and low CO2 emissions
2
1
• Easy to install
• Total solution for year round comfort
38 • Altherma • Outdoor units
2
• Outdoor units • R-410A • ERHQ011-016AA
Specifications
2-1 NOMINAL CAPACITY AND
NOMINAL INPUT
Indoor Units For combination indoor units + outdoor units
Condition 1 Nominal kW
Nominal
Capacity
Heating capacity
Cooling capacity
Heating PI
Cooling PI
COP
EER
Heating capacity
Cooling capacity
Heating PI
Cooling PI
COP
EER
Notes
Nominal kW
Nominal kW
For combination indoor units + outdoor units
Nominal kW
Nominal kW
Nominal
Nominal
Nominal kW
Nominal kW
Nominal kW
Nominal
Nominal
2-2 TECHNICAL SPECIFICATIONS
Casing
Dimensions
Weight
Packing
Colour
Material
Unit
Packing
Unit
Packed Unit
Material
Height
Width
Depth
Height
Width
Depth mm mm kg kg mm mm mm mm
Heat
Exchanger
Weight
Dimensions
Tube type
Fin
Fan
Air Flow Rate
(nominal at
230V)
Type
Quantity
Heating
Cooling
Length
Nr of Rows kg mm
Fin Pitch mm
Nr of Passes
Face
Area
Nr of Stages m²
Type
Treatment
High
High m³/min m³/min
ERHQ011AA
EKHBH016AA
ERHQ014AA
EKHBH016AA
ERHQ016AA
EKHBH016AA
ERHQ011AA
EKHBX016AA
ERHQ014AA
EKHBX016AA
ERHQ016AA
EKHBX016AA
11.2
2.46
4.55
10.3
14.0
3.17
4.42
13.1
16.0
3.83
4.18
15.2
11.2
13.9
2.46
3.79
4.55
3.67
10.3
10.0
14.0
17.3
3.17
5.78
4.42
2.99
13.1
12.5
16.0
17.8
3.06
3.37
3.88
3.38
4.66
3.26
3.06
3.60
3.37
2.78
3.88
5.29
3.38
2.36
4.66
5.95
3.26
2.20
Condition 1: cooling Ta 35°C - LWE 18°C - heating Ta DB/WB 7°C/6°C - LWC 35°C ( DT = 5°C )
Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
3.83
6.77
4.18
2.63
15.2
13.1
ERHQ011AA ERHQ014AA
11
857
2
1.4
6
0.98
52
980
420
103
114
1170
900
320
1349
2
90
1170
900
320
1349
980
420
103
114
11
857
2
1.4
6
0.98
52
2
90
ERHQ016AA ERHQ011AA
Ivory white
Painted galvanised steel plate
1170
900
1170
900
320
1349
980
420
103
114
320
1349
980
420
103
114
EPS
Carton
Wood
PP (Straps)
11
857
2
1.4
6
0.98
11
857
2
1.4
6
0.98
52
2
90
52
Hi-XSS(8)
WF fin
Anti-corrosion treatment (PE)
Propeller
2
90
96
ERHQ014AA
11
857
2
1.4
6
0.98
52
980
420
103
114
1170
900
320
1349
2
90
100
ERHQ016AA
11
857
2
1.4
6
0.98
52
980
420
103
114
1170
900
320
1349
2
90
97
2
2
• Altherma • Outdoor units 39
2
• Outdoor units • R-410A • ERHQ011-016AA
Specifications
2
2
2-2 TECHNICAL SPECIFICATIONS
Fan
Motor
Fan
Compressor
Operation
Range
Discharge direction
Motor Quantity
Model
Output
Speed
(nominal)
W
Steps
Heating rpm
Motor
Cooling rpm
Output W
Drive
Quantity
Motor
Heating
Model
Type
Motor
Output
W
Starting Method
Crankcase
Heater
W
Min
Max
°CWB
°CWB
°CDB
°CDB
°CDB
°CDB dBA Sound Level
(nominal)
Sound Level
(Night quiet)
Cooling
Sanitary water Min
Max
Heating
Min
Max
Sound
Power
Sound
Pressure
Cooling
Heating
Cooling
Sound
Power
Sound
Pressure
Sound
Pressure
Sound
Pressure
Refrigerant Type
Charge
Control
Nr of Circuits
Refrigerant Oil Type
Charged Volume l dBA dBA dBA dBA dBA kg
ERHQ011AA
2200
3.7
1
1.0
33
-20
35
-20
43
49
42
2
70
8
760
70
1
ERHQ014AA
2
70
8
760
70
1
2200
ERHQ016AA ERHQ011AA
70
8
760
Horizontal
2
Brushless DC motor
2
70
70
8
760
800
70
Direct drive
1 1
JT100G-VD
Hermetically sealed scroll compressor
2200 2200
ERHQ014AA
2
70
8
760
850
70
1
2200
33
-20
35
-20
43
33
Inverter driven
33
-20
35
-20
43
-20
43
64
-20
35
10
46
33
-20
43
64
-20
35
10
46
51
42
3.7
1
1.0
53
50
42
49
64
43
45
R-410A
3.7
3.7
Expansion valve (electronic type)
1 1
1.0
Daphne FVC68D
1.0
52
42
51
66
45
3.7
1
1.0
ERHQ016AA
2200
54
43
53
69
46
33
-20
43
66
-20
35
10
46
2
70
8
760
830
70
1
3.7
1
1.0
40 • Altherma • Outdoor units
2
• Outdoor units • R-410A • ERHQ011-016AA
Specifications
2-2 TECHNICAL SPECIFICATIONS
Piping connections
Liquid (OD)
Gas
Quantity
Type
Diameter
(OD)
Quantity
Type
Diameter
(OD) mm mm
Drain Quantity
Type
Diameter
(OD) mm
Piping Length Minimum m
Maximum m
Equivalent m
Chargeless m
Additional Refrigerant Charge kg/m
Installation height difference
Maximum m
Heat Insulation
Defrost Method
Defrost Control
Capacity Control Method
Safety Devices
Standard
Accessories
Item
Quantity
Item
Quantity
Notes
2-3 ELECTRICAL SPECIFICATIONS
Power Supply Name
Phase
Current
Frequency
Voltage
Voltage range Minimum V
Maximum V
Maximum running
Current
Hz
V
Cooling A
A
Wiring connections
Recomended fuses
For Power
Supply
Remark
Remark For connection with indoor
Power Supply Intake
3
26
5
75
95
30
30
ERHQ011AA
1
1
ERHQ014AA
1
ERHQ016AA ERHQ011AA
1
Flare connection
9,52
1
ERHQ014AA
1
1
3
1
Flare connection
15,9
1
3 3
Hole
26 26
1
3
26 26
5
75
95
30
30
5
75
95
30
5
75
95
30
See installation manual outdoor unit 4PW37976-1B
30 30
5
75
95
30
30
1
Both liquid and gas pipes
Pressure equalising
Sensor for outdoor heat exchanger temperature
Inverter controlled
Fan motor thermal protector
Fuse
High pressure switch
Tie-wraps
2 2 2
Installation manual
2 2 2
1 1 1 1 1 1
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
Down to 3m with recharging of the outdoor unit. Refer to the installation manual of the outdoor unit.
ERHQ011AA ERHQ014AA ERHQ014AA ERHQ016AA
50
230
50
230
ERHQ016AA
50
230
ERHQ011AA
V3
1~
50
230
-10%
+10%
22.8
50
230
27.4
50
230
31.9
32 32 32 32
See installation manual outdoor unit 4PW37976-1B
32
See installation manual outdoor unit 4PW37976-1B
Outdoor unit only
ERHQ016AA
1
3
26
5
75
95
30
30
32
2
2
• Altherma • Outdoor units 41
2
3
• Outdoor units • R-410A • ERHQ011-016AA
3 Capacity tables
3 - 1 Heating capacity tables
42 • Altherma • Outdoor units
• Outdoor units • R-410A • ERHQ011-016AA
3 Capacity tables
3 - 2 Cooling capacity tables
2
3
• Altherma • Outdoor units 43
2
4
• Outdoor units • R-410A • ERHQ011-016AA
4 Dimensional drawing & centre of gravity
4 - 1 Dimensional drawing
44 • Altherma • Outdoor units
5
• Outdoor units • R-410A • ERHQ011-016AA
Piping diagram
2
5
• Altherma • Outdoor units 45
2
6
• Outdoor units • R-410A • ERHQ011-016AA
6 Sound data
6 - 1 Sound pressure spectrum
ERHQ011-016 AA
ERHQ011AAV3
HEATING
ERHQ014AAV3
HEATING
ERHQ016AAV3
HEATING
Octave band center frequency (Hz) Octave band center frequency (Hz)
NOTES
1 Data is valid at free field condition (measured in a semi-anachoic room).
2 dBA = A-Weighted sound pressure level. (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa.
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
ERHQ011-016AA
ERHQ011AAV3
COOLING
ERHQ014AAV3
COOLING
Octave band center frequency (Hz)
3TW57767-2A
Measuring location
(Discharge side)
ERHQ016AAV3
COOLING
Octave band center frequency (Hz) Octave band center frequency (Hz)
46
NOTES
1 Data is valid at free field condition (measured in a semi-anachoic room).
2 dBA = A-Weighted sound pressure level. (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa.
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
• Altherma • Outdoor units
Octave band center frequency (Hz)
3TW57767-1A
Measuring location
(Discharge side)
• Outdoor units • R-410A • ERHQ011-016AA
6 Sound data
6 - 1 Sound pressure spectrum
ERHQ011-016 AA
ERHQ011AAV3
HEATING
ERHQ014AAV3
HEATING
ERHQ016AAV3
HEATING
2
6
Octave band center frequency (Hz) Octave band center frequency (Hz)
NOTES
1 Data is valid at free field condition (measured in a semi-anachoic room).
2 dBA = A-Weighted sound pressure level. (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa.
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
ERHQ011-016 AA
ERHQ011AAV3
COOLING
ERHQ014AAV3
COOLING
Octave band center frequency (Hz)
3TW57767-4
Measuring location
(Discharge side)
ERHQ016AAV3
COOLING
Octave band center frequency (Hz) Octave band center frequency (Hz)
NOTES
1 Data is valid at free field condition (measured in a semi-anachoic room).
2 dBA = A-Weighted sound pressure level. (A-scale according to IEC)
3 Reference acoustic pressure 0dB = 20μPa.
4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.
• Altherma • Outdoor units
Octave band center frequency (Hz)
3TW57767-3
Measuring location
(Discharge side)
47
• Indoor units • R-410A • EKHBH(X)016AB
TABLE OF CONTENTS
EKHBH(X)016AB
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Dimensional drawing & centre of gravity
. . . . . . . . . . . . . . . . . . . . . . . 57
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
• Altherma • Indoor units 49
• Indoor units • R-410A • EKHBH(X)016AB
1 Features
B A 6 1 n 0 u a X m A o H e 0 1 B h o H d 4 K n E A R • Cost effective alternative to a fossil fuel boiler
• Low energy bills and low CO2 emissions
2
1
• Easy to install
• Total solution for year round comfort
50 • Altherma • Indoor units
2
• Indoor units • R-410A • EKHBH(X)016AB
Specifications
2-1 TECHNICAL SPECIFICATIONS
Outdoor units
Nominal input (Indoor only)
Casing Colour
Material
Dimensions Packing
Weight
Packing
Main components
Unit
Height
Width
Depth
Height (1)
W
Width
Depth
Machine weight
Gross Weight
Material
Material
Material
Material
Weight
Pump
Water side
Heat exchanger kg
Type
Nr. of speed
Nominal
ESP unit
Heating
Cooling kPa kPa
W Power input
Type
Qty
Water volume
Water flow rate Min.
Water flow rate Nom.
l l/min
Heating (3) l/min
Cooling (2) l/min
Water flow rate Max.
Insulation material l/min mm mm kg kg mm mm mm mm
Water circuit
Expansion vessel
Volume
Max. water pressure
Pre pressure
Water filter Diameter perforations
Material
Piping connections diameter
Piping
Safety valve l bar bar mm inch inch bar
Refrigerant
Circuit
Manometer
Drain valve / Fill valve
Shut off valve
Air purge valve
Total water volume (6)
Gas side diameter
Liquid side diameter
Sound Pressure (5) Sound
Level
Operation range
Ambient Heating
Cooling
Waterside Heating (5)
Cooling
Outdoor units
Nominal input (Indoor only)
Casing Colour
Material l mm mm dBA
°C
°C
°C
°C
W
EKHBH016AB
ERHQ011AAV3
230
RAL9010
Epoxy polyester painted galvanised steel
1225
660
610
922
502
361
55
65
EPS
Wood
Carton
PP (Straps)
10
Water cooled
2
52.5
EKHBX016AB
55.9
210
Brazed plate
1
1.01
16
32.1
28.7
58
Polyurethane foam
10
3
1
1
Brass
1-1/4'' MBSP
1-1/4''
3
Yes
Yes
Yes
Yes
5.5
15.9
9.52
28
-20~35
10~46
15~55
5~22
ERHQ014AAV3
230
RAL9010
Epoxy polyester painted galvanised steel
• Altherma • Indoor units
2
2
51
2
• Indoor units • R-410A • EKHBH(X)016AB
Specifications
2
2
2-1 TECHNICAL SPECIFICATIONS
Dimensions Packing
Weight
Unit
Height
Width
Depth
Height (1)
Machine weight
Gross Weight
Width
Depth
Packing
Main components
Material
Material
Material
Material
Weight
Pump
Water side
Heat exchanger kg
Type
Nr. of speed
Nominal
ESP unit
Heating
Cooling kPa kPa
W Power input
Type
Qty
Water volume
Water flow rate Min.
Water flow rate Nom.
l l/min
Heating (3) l/min
Cooling (2) l/min
Water flow rate Max.
Insulation material l/min mm mm kg kg mm mm mm mm l bar bar mm
Water circuit
Expansion vessel
Volume
Max. water pressure
Pre pressure
Water filter Diameter perforations
Material
Piping connections diameter
Piping
Safety valve
Refrigerant
Circuit
Manometer
Drain valve / Fill valve
Shut off valve
Air purge valve
Total water volume (6)
Gas side diameter
Liquid side diameter
Sound Pressure (5) Sound
Level
Operation range
Ambient Heating
Cooling
Waterside Heating (5)
Cooling
Outdoor units
Nominal input (Indoor only)
Casing Colour
Material
Dimensions Packing
Unit
Height
Width
Depth
Height (1)
Width
Depth l inch inch bar mm mm dBA
°C
°C
°C
°C
W mm mm mm mm mm mm
52 • Altherma • Indoor units
EKHBH016AB EKHBX016AB
502
361
55
65
1225
660
610
922
EPS
Wood
Carton
PP (Straps)
10
Water cooled
2
43.5
49.1
210
Brazed plate
1
1.01
16
40.1
35.8
58
Polyurethane foam
10
3
1
1
Brass
1-1/4'' MBSP
1-1/4''
Yes
5.5
15.9
9.52
28
3
Yes
Yes
Yes
-20~35
10~46
15~55
ERHQ016AAV3
230
RAL9010
Epoxy polyester painted galvanised steel
1225
660
610
922
502
361
5~22
2
• Indoor units • R-410A • EKHBH(X)016AB
Specifications
2-1 TECHNICAL SPECIFICATIONS
Weight
Packing
Main components
Water circuit
Refrigerant
Circuit
Machine weight
Gross Weight
Material
Material
Material
Material
Weight
Pump
Water side
Heat exchanger kg kg kg
Type
Nr. of speed
Nominal
ESP unit
Heating
Cooling kPa kPa
W Power input
Type
Qty
Water volume
Water flow rate Min.
Water flow rate Nom.
l l/min
Heating (3) l/min
Cooling (2) l/min
Water flow rate Max.
Insulation material l/min
Expansion vessel
Volume
Max. water pressure
Pre pressure
Water filter Diameter perforations
Material
Piping connections diameter
Piping
Safety valve l bar bar mm inch inch bar
Manometer
Drain valve / Fill valve
Shut off valve
Air purge valve
Total water volume (6)
Gas side diameter
Liquid side diameter
Sound Pressure (5) l mm mm dBA Sound
Level
Operation range
Ambient Heating
Cooling
Waterside Heating (5)
Cooling
°C
°C
°C
°C
Notes
Notes
Notes
Notes
Notes
Notes
EKHBH016AB EKHBX016AB
55
65
EPS
Wood
Carton
PP (Straps)
10
Water cooled
2
35.0
46.8
210
Brazed plate
1
1.01
16
45.9
37.6
58
Polyurethane foam
10
3
1
1
Brass
1-1/4'' MBSP
1-1/4''
3
Yes
Yes
Yes
Yes
5.5
15.9
9.52
28
-20~35
10~46
15~55
5~22
(1) With option kit EKHBDP installed: Height=936mm
(2) Tamb 35°C - LWE 7°C (DT=5°C)
(3) DB/WB 7°C/6°C-LWC 35°C(DT=5°C)
(4) The sound pressure level is measured via a microphone at 1m from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is valid for pump medium speed.
(5) 15°C-25°C: BUH only, no Heatpump operation=during commissioning.
(6) Including piping+PHE+backup heater/excluding expansion vessel.
2
2
• Altherma • Indoor units 53
2
• Indoor units • R-410A • EKHBH(X)016AB
Specifications
2
2
2-2 ELECTRICAL SPECIFICATIONS
Electric heater
Electric heater
Electric heater
Electric heater
Electric heater
Type
Power
Supply
Phase
Frequency
Voltage
Current Running Current
Voltage
Range
Minimum
Maximum
Wiring
Connections
For power supply backup heater
Hz
V
A
Quantity of wires
Type of wires
Type
Power
Supply
Phase
Frequency
Voltage
Current Running Current
Voltage
Range
Minimum
Maximum
Wiring
Connections
For power supply backup heater
Hz
V
A
Quantity of wires
Type of wires
Type
Power
Supply
Phase
Frequency
Voltage
Current Running Current
Voltage
Range
Minimum
Maximum
Wiring
Connections
For power supply backup heater
Hz
V
A
Quantity of wires
Type of wires
Type
Power
Supply
Phase
Frequency
Voltage
Current Running Current
Voltage
Range
Minimum
Maximum
Wiring
Connections
For power supply backup heater
Hz
V
A
Quantity of wires
Type of wires
Type
Power
Supply
Phase
Frequency
Voltage
Current Running Current
Voltage
Range
Minimum
Maximum
Wiring
Connections
For power supply backup heater
Hz
V
A
Quantity of wires
Type of wires
EKHBH016AB EKHBX016AB
3V3
1~
50
230
13
-10%
+10%
3G
Select diameter and type according to national and local regulations
6V3
1~
50
230
26
-10%
+10%
3G
Select diameter and type according to national and local regulations
6WN
3~
50
400
8.7
-10%
+10%
4G
Select diameter and type according to national and local regulations
6T1
3~
50
230
15.1
-10%
+10%
4G
Select diameter and type according to national and local regulations
9WN
3~
50
400
13
-10%
+10%
4G
Select diameter and type according to national and local regulations
54 • Altherma • Indoor units
2
• Indoor units • R-410A • EKHBH(X)016AB
Specifications
2-2 ELECTRICAL SPECIFICATIONS
Electric heater
Wiring
Connections
Type
Power
Supply
Phase
Frequency
Voltage
Current Running Current
Voltage
Range
Minimum
Maximum
Hz
V
A
Quantity of wires
Type of wires
Wiring
Connections
For power supply backup heater
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
Connection type
Quantity of wires
Type of wires
EKHBH016AB EKHBX016AB
9T1
3~
50
230
22.6
-10%
+10%
4G
Select diameter and type according to national and local regulations
For power supply connection to Optional Warm Water Tank + Q2L
3G
Select diameter and type according to national and local regulations
For more details of the voltage range and current refer to installation manual EKHBH/X016AB*
For connection with R5T
Wire included in option EKHWS*
Wire included in option EKHWS*
For connection with A3P
Depends on thermostat type, refer to installation manual EKHBH/X016AB*
Select diameter and type according to national and local regulations
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
For connection with M2S
3G
Select diameter and type according to national and local regulations
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
For connection with M3S
3G or 4G
Select diameter and type according to national and local regulations
Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²
2
2
• Altherma • Indoor units 55
• Indoor units • R-410A • EKHBH(X)016AB
3 Options
2
3
Factory mounted optional equipment for EKHB(H/X)016AB**
3V3
6V3
6W1
6T1
9W1
9T1
Reference Description
Heating only model EKHBH016A...
Reversible model EKHBX016A...
Back up heater 3kW 1 ∼230 V
Back up heater 6kW 1 ∼230 V
Back up heater 6kW 3 ∼400 V
Back up heater 6kW 3 ∼230 V
Back up heater 9kW 3 ∼400 V
Back up heater 9kW 3
∼230 V
Outdoor combination table for EKHB(H/X)016AB**
B3V3
B3V3
B6V3
B6V3
B6V3
B6WN
B6T1
B6T1
B9WN
B9WN
B9T1
B9T1
V V
⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯
⎯ ⎯
V V
⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯
⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯ ⎯ ⎯ ⎯ ⎯
⎯ ⎯ ⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯ ⎯ ⎯
⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯
⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯
V V
EKHBH016AB*
EKHBX016AB*
Kit availability for ERHQ011-016AA**
Heating only indoor unit
Reversible indoor unit
ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3
V
V
V
V
V
V
EKBPHT16 Bottom plate heater (1)
Kit availability for EKHB(H/X)016AB*
ERHQ011AAV3 ERHQ014AAV3 ERHQ016AAV3
V V V
Reference
EKHWS150A3V3
EKHWS200A3V3
EKHWS300A3V3
EKHWS200A3Z2
EKHWS300A3Z2
EKHWSU150A3V3
EKHWSU200A3V3
EKHWSU300A3V3
EKHBDP
EKRP1HB
(*) If neutral line is available
Kit available for EKHWS*
Description
Heating only model EKHBH016A...
Reversible model EKHBX016A...
Domestic hot water tank 150l 1-230V
Domestic hot water tank 200l 1-230V
Domestic hot water tank 300l 1-230V
Domestic hot water tank 200l 2-400V
Domestic hot water tank 300l 2-400V
Domestic hot water tank 150l 1-230V
Domestic hot water tank 200l 1-230V
Domestic hot water tank 300l 1-230V
Option kit for condensate free cooling operation
Digital I/O PCB (2)
B3V3 B6V3 B6WN B6T1 B9WN B9T1
B3V3 B6V3 B6WN B6T1 B9WN B9T1
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯
V V
⎯ ⎯
⎯ ⎯ ⎯ ⎯
V V
⎯ ⎯
V V
⎯ ⎯
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
V V V V V
(*) V (*)
V V V
(*) V (*)
V V
⎯
V
⎯
V
⎯
V
⎯
V
⎯
V
⎯
V
V V V V V V V V V V V V
Reference
EKUHWA
EKSOLHWAV1
EKWBSWW150
Description
EKHWS...
EKHWSU...
Option kit for UK EKHWSU150-300V3
Solarkit (3)
Wall bracket for EKSWW150V3
15A3V3 200A3V3/Z2 300A3V3/Z2
⎯
V
V
⎯
V
⎯
⎯
V
⎯
150A3V3 200A3V3 300A3V3
V V V
V
V
V
⎯
V
⎯
Remarks: Other combinations are not guaranteed
(1) Heater tape that can be fixed on the bottom plate to prevent ice formation.
(2) Address card that provides two additional output connections (remote alarm and remote ON/OFF signalisation). In EKSOLHWAV1, the same digital I/O
PCB as for EKRP1HB is already included.
(3) Kit to be mounted on domestic hot water tank that provides connection to solar panels for additional water heating.
3TW57819-2
56 • Altherma • Indoor units
• Indoor units • R-410A • EKHBH(X)016AB
4 Dimensional drawing & centre of gravity
4 - 1 Dimensional drawing
EKHBH016AB
FIXATION
Dimensions wallbracket
Minimum space for service & ventilation
Min. 200
Center of gravity
Pump + switch for speed setting
Remocon
Water IN connection: 1 1/4’’ M BSP
Water OUT connection: 1 1/4’’ M BSP
Power supply intake (+ sanitary warm water tank)
Air purge
Expansion vessel+j nipple+j Drain
Blow off valve
Blow off drain (flexible hose J20)
Pressure gauge
Water filter
Suction pipe connection J15.9 flare connection
Liquid pipe connection J9.52 flare connection
Shut off valves with drain/fill valve (accessory delivered with unit)
Holes for fixation
Switchbox terminals
Switchbox terminals option sanitary warm water tank
Wallbracket
EKHBX016AB
FIXATION
1-1/4 ″ Male BSP
Service door
(Closed) 361
(Open) 553
View A
Scale 1/5
3TW57754-1A
2
4
Dimensions wallbracket
Minimum space for service & ventilation
Min. 200
Center of gravity
Pump + switch for speed setting
Remocon
Water IN connection: 1 1/4’’ M BSP
Water OUT connection: 1 1/4’’ M BSP
Power supply intake (+ sanitary warm water tank)
Air purge
Expansion vessel+j nipple+j Drain
Blow off valve
Blow off drain (flexible hose J20)
Pressure gauge
Water filter
Suction pipe connection J15.9 flare connection
Liquid pipe connection J9.52 flare connection
Shut off valves with drain/fill valve (accessory delivered with unit)
Holes for fixation
Switchbox terminals
Switchbox terminals option sanitary warm water tank
Wallbracket
1-1/4 ″ Male BSP
Service door
(Closed) 361
(Open) 553
View A
Scale 1/5
Dimensions wallbracket Scale 1/5
3TW57754-2A
• Altherma • Indoor units 57
5
• Indoor units • R-410A • EKHBH(X)016AB
Piping diagram
2
5
EKHBH(X)016 AB
Water Site
Field Installation
Flowswitch
R2T
Pressure
Gauge
Expansion
Vessel
Drain
Blow Off
Pump
Safety
Valve
Air
Purge
R1T
Water Outlet
Shut Off Valve
With Drain/Fill Valve
Electric
Heater Body
Field Installation
Water Inlet
Shut Off Valve
With Drain/Fill Valve
Check Valve Flare Conn.
Filter
R4T
Screw Conn.
Flange Conn.
Pinched Pipe
Evaporator
Condensor
Refriferant
Side
Refr. Out
Refr. In
Plate
Heat
Exchanger
Spinned Pipe
R3T
Refr. In
Refr. Out
Cooling (EKHBX)
Heating (EKHBX + EKHBH)
R4T
R3T
R2T
R1T
Thermistor
Inlet water Thermistor
Refrigerant Liquid Side Thermistor
Outlet Water Backup heater Thermistor
Outlet Water Heat-exchanger Thermistor
Description
3TW57755-1
58 • Altherma • Indoor units
• Indoor units • R-410A • EKHBH(X)016AB
6 Wiring diagram
6 - 1 Wiring diagram
EKHBH(X)016AB3V3
Power supply
230V 1N ∼50Hz
>> See note 2 <<
Outdoor unit
Only for EKSOLHWAV1
Option
Solar pump connection
See note 9
Domestic hot water tank
Only for EKHW*V3 Option
See note 7
For EKHWSU*V3
Option
User interface
2
6
Domestic hot water tank
Only forEKHW*V3
Option
See note 7
For EKHWSU*V3 Option
Wiring dependent on model
Field wiring
Option
Field wiring
Only for EKRP1HB
Option
See note 8
PCB
Wire colour
NO valve
Spring return type
230V AC supply from
PCB
Only for EKSWW option
F1B
Electric heater option fuse
20A
Thermostat
On/Off
NC valve
Notes:
1 This wiring diagram only applies to the indoor unit.
3 wire type
(SPST)
2 Use one and same dedicated power supply for indoor ubit, outdoor unit and EKHW option.
3 :Field wiring No/No normal open/normal closed SPST - single pole single throw.
4 :Terminal strip :Connector :Terminal :Protective earth
5 Do not operate the unit by short-sircuiting any protection device.
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet
7 For EKHWSU*V3, refer to option manual
8 Option PCB works with an external 230V AC power supply unit.
9 For EKSOLHWAV1, refer to option manual
F2B
EKHW kit fuse
20A
Only for EKHW*V3
Option
EKHBH(X)016AB6V3
Power supply
230V 1N ∼50Hz
>> See note 2 <<
Outdoor unit
Only for EKSOLHWAV1
Option
Solar pump connection
See note 9
Domestic hot water tank
Only for EKHW*V3 Option
See note 7
For EKHWSU*V3
Option
Only for EKHW Option
K7M
K4M
K3M
K1M
F2B
F1B
F1T
A4P
A3P
A2P
A1P
R1T
S1L
E4H
E1H
M3S
M2S
M1P
PHC1
K5M
Q1L
S1S
SS1
TR1
R5T
R4T
R3T
R2T
X1M-X4M
V2S
V1S
FU1
FU2
FuS, FuR
Q1DI
Q2L
: Terminal strips
: Spark suppression 2
: Spark suppression 1
: Fuse 3.15A T 250V
: Fuse 5A T 250V
: Fuse 5A 250V for solar/remote alarm PCB
: Earth leakage protector
: Thermal protector booster heater
: Thermal protector backup heater
: Solar pumpstation relay
: DIP switch
: Transformer 24V for PCB
: Domestic hot water thermistor
: Inlet water thermistor
: Refrigerant liquid side thermistor
: Outlet water backup heater thermistor
: Outlet water heat-exchanger thermistor
: Flowswitch
: Booster heater
: Backup heater element 1
: 3way valve: floorheating/domestic hot water
: 2 way valve for cooling mode
: Pump
: Aplocoupler input circuit
: Contactor for backup heater all-pole disconnection
: Relay for solar pump
: Pump Relay
: Contactor booster heater
: Contactor backup heater Step 1
: Fuse booster heater
: Fuse backup heater
: Thermal fuse Back up heater
: Solar/remote alarm PCB
: Thermostat (PC-power circuit)
: User interface PCB
: Main PCB
3TW57816-2
User interface
Domestic hot water tank
Only forEKHW*V3
Option
See note 7
For EKHWSU*V3 Option
Wiring dependent on model
Field wiring
Only for EKHW
Option
Option
Field wiring
Only for EKRP1HB
Option
See note 8
PCB
Wire colour
Thermostat
230V AC supply from
PCB
NO valve
Spring return type
On/Off
NC valve
3 wire type
(SPST)
Notes:
1 This wiring diagram only applies to the indoor unit.
2 Use one and same dedicated power supply for indoor ubit, outdoor unit and EKHW option.
3
4
:Field wiring No/No normal open/normal closed SPST - single pole single throw.
:Terminal strip :Connector :Terminal :Protective earth
5 Do not operate the unit by short-sircuiting any protection device.
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet
7 For EKHWSU*V3, refer to option manual
8 Option PCB works with an external 230V AC power supply unit.
9 For EKSOLHWAV1, refer to option manual
F1B
F2B
EKHW kit fuse
F2B
F1B
F1T
A4P
A3P
A2P
A1P
20A
Only for EKSWW option
Electric heater option fuse
32A
Only for EKHW*V3
Option
Q1L
S1S
SS1
TR1
R5T
R4T
R3T
R2T
X1M-X4M
V2S
V1S
FU1
FU2
FuS, FuR
Q1DI
Q2L
R1T
S1L
E4H
E1H-E2H
M3S
: Fuse booster heater
: Fuse backup heater
: Thermal fuse Back up heater
: Solar/remote alarm PCB
: Thermostat (PC-power circuit)
: User interface PCB
: Main PCB
M2S
M1P
PHC1
K5M
K7M
K3M
K1M/K2M
: Terminal strips
: Spark suppression 2
: Spark suppression 1
: Fuse 3.15A T 250V
: Fuse 5A T 250V
: Fuse 5A 250V for solar/remote alarm PCB
: Earth leakage protector
: Thermal protector booster heater
: Thermal protector backup heater
: Solar pumpstation relay
: DIP switch
: Transformer 24V for PCB
: Domestic hot water thermistor
: Inlet water thermistor
: Refrigerant liquid side thermistor
: Outlet water backup heater thermistor
: Outlet water heat-exchanger thermistor
: Flowswitch
: Booster heater
: Backup heater element 1-2
: 3way valve: floorheating/domestic hot water
: 2 way valve for cooling mode
: Pump
: Aplocoupler input circuit
: Contactor for backup heater all-pole disconnection
: Relay for solar pump
: Contactor booster heater
: Contactor backup heater Step 1/2
3TW57816-3
• Altherma • Indoor units 59
2
6
• Indoor units • R-410A • EKHBH(X)016AB
6 Wiring diagram
6 - 1 Wiring diagram
EKHBH(X)016AB6T1/9T1
Power supply
3-230V 50Hz
>> See note 2 <<
Outdoor unit
Only for EKSOLHWAV1
Option
Solar pump connection
See note 9
Domestic hot water tank
Only for EKHW*V3 Option
See note 7
For EKHWSU*V3
Option
User interface
Only for EKHW
Option
Domestic hot water tank
Only forEKHW*V3
Option
See note 7
For EKHWSU*V3 Option
Only for EKRP1HB
Option
See note 8
Wiring dependent on model
Field wiring
Option
Field wiring
PCB
Wire colour
230V AC supply from
PCB
NO valve
Spring return type
Only for EKSWW option
Only for EKHW*V3
Option
Thermostat Model
F1B
Electric heater option fuse
6T1
20A
9T1
32A
On/Off
NC valve
3 wire type
(SPST)
F2B
EKSWW kit fuse
20A
Notes:
1 This wiring diagram only applies to the indoor unit.
2 Use one and same dedicated power supply for indoor ubit, outdoor unit and EKHW option.
3 :Field wiring No/No normal open/normal closed SPST - single pole single throw.
4 :Terminal strip :Connector :Terminal :Protective earth
5 Do not operate the unit by short-sircuiting any protection device.
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet
7 For EKHWSU*V3, refer to option manual
8 Option PCB works with an external 230V AC power supply unit.
9 For EKSOLHWAV1, refer to option manual
EKHBH(X)016AB6WN/9WN
Power supply
3(/N)-400(/230V) 50Hz
>> See note 2 <<
Outdoor unit
Only for EKSOLHWAV1
Option
Solar pump connection
See note 9
Domestic hot water tank
Only for EKHW*V3 Option
See note 7
For EKHWSU*V3
Option
Domestic hot water tank
Only for EKHW*Z2
Option
S1L
E4H
E1H-E3H
M3S
M2S
M1P
PHC1
K5M
K7M
K3M
K1M/K2M
F2B
F1B
F1T
A4P
A3P
A2P
A1P
Q1L
S1S
SS1
R5T
R4T
R3T
R2T
R1T
X1M-X4M
V2S
V1S
FU1
FU2
FuS, FuR
Q1DI
Q2L/Q3L
: Terminal strips
: Spark suppression 2
: Spark suppression 1
: Fuse 3.15A T 250V
: Fuse 5A T 250V
: Fuse 5A 250V for solar/remote alarm PCB
: Earth leakage protector
: Thermal protector booster heater
: Thermal protector backup heater
: Solar pumpstation relay
: DIP switch
: Domestic hot water thermistor
: Inlet water thermistor
: Refrigerant liquid side thermistor
: Outlet water backup heater thermistor
: Outlet water heat-exchanger thermistor
: Flowswitch
: Booster heater
: Backup heater element 1
: 3way valve: floorheating/domestic hot water
: 2 way valve for cooling mode
: Pump
: Aplocoupler input circuit
: Contactor for backup heater all-pole disconnection
: Relay for solar pump
: Contactor booster heater
: Contactor backup heater Step 1
: Fuse booster heater
: Fuse backup heater
: Thermal fuse Back up heater
: Solar/remote alarm PCB
: Thermostat (PC-power circuit)
: User interface PCB
: Main PCB
3TW57816-6
User interface
60
Domestic hot water tank
Domestic hot water tank
Only forEKHW*V3
Option
Only forEKHW*Z2
Option
See note 7
For EKHWSU*V3 Option
Wiring dependent on model
Field wiring
Option
Field wiring
Only for EKRP1HB
Option
See note 8
PCB
Wire colour
Thermostat
On/Off
230V AC supply from
PCB
NO valve
Spring return type
NC valve
3 wire type
(SPST)
Notes:
1 This wiring diagram only applies to the indoor unit.
2 Use one and same dedicated power supply for indoor ubit, outdoor unit and EKHW option.
3
4
:Field wiring No/No normal open/normal closed SPST - single pole single throw.
:Terminal strip :Connector :Terminal :Protective earth
5 Do not operate the unit by short-sircuiting any protection device.
6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet
7 For EKHWSU*V3, refer to option manual
8 Option PCB works with an external 230V AC power supply unit.
9 For EKSOLHWAV1, refer to option manualCB
Model
F1B
Only for EKSWW option
Only for EKHW*V3
Option
Electric heater option fuse
6WN
16A
9WN
20A
F2B
EKHW kit fuse
20A
X1M-X4M
V2S
V1S
FU1
FU2
FuS, FuR
Q1DI
Q2L
Q1L/Q3L
S1S
SS1
TR1
R5T
R4T
R3T
R2T
R1T
S1L
E4H
E1H-E3H
M3S
Only for EKHW
Option
M2S
M1P
PHC1
K5M
K7M
K3M
K1M/K2M
F2B
F1B
F1T
A4P
A3P
A2P
A1P
: Terminal strips
: Spark suppression 2
: Spark suppression 1
: Fuse 3.15A T 250V
: Fuse 5A T 250V
: Fuse 5A 250V for solar/remote alarm PCB
: Earth leakage protector
: Thermal protector booster heater
: Thermal protector backup heater
: Solar pumpstation relay
: DIP switch
: Transformer 24V for PCB
: Domestic hot water thermistor
: Inlet water thermistor
: Refrigerant liquid side thermistor
: Outlet water backup heater thermistor
: Outlet water heat-exchanger thermistor
: Flowswitch
: Booster heater
: Backup heater element 1-3
: 3way valve: floorheating/domestic hot water
: 2 way valve for cooling mode
: Pump
: Aplocoupler input circuit
: Contactor for backup heater all-pole disconnection
: Relay for solar pump
: Contactor booster heater
: Contactor backup heater Step 1/2
: Fuse booster heater
: Fuse backup heater
: Thermal fuse Back up heater
: Solar/remote alarm PCB
: Thermostat (PC-power circuit)
: User interface PCB
: Main PCB
3TW57816-4
• Altherma • Indoor units
• Indoor units • R-410A • EKHBH(X)016AB
6 Wiring diagram
6 - 2 External connection diagram
Electrical connection diagram Altherma
Standard parts
Outdoor unit
Power supply
Unit power supply: 230V + earth
3 core
Backup heater power supply (3/6/9kW): 400V or 230V + earth
Optional power supply
Booster heater power supply (3kW): 400V or 230V + earth
Optional parts
Sanitary tank
X1M:L-N-Earth
Bottom plate heater option
X1M:1-2-3-Earth
Only for EKBPHT16
4 core
<10m: 4Gx1.5
>10m: 4Gx2.5
Indoor unit
X1M:1-2-3-Earth
X1M:L1-L2-L3-N-Earth
X3M:L-N-Earth
2 way valve
Q3L
0,3L secondary clixon
2 core
5 core
Only for EKHWSU*V3
X4M:1-2-Earth
For more details please check unit wiring diagram
2 core
2 core
2 core
4 core
Field supply
Alarm output
Unit on/off output
Solar input
Only for EKRP1HB & EKSOLHWAV1
Room thermostat
Power supply booster heater
Q2L - Clixon booster heater
R5T - Thermistor water temperature
Q3L
0,3L secondary clixon
Note: min. distance to power cable = 3cm
2 core
Signal
2 core
Solar pump
X1M:7-8-Earth
NO valve:
NC valve:
Spring return
2 core
2 core
2 way valve
M2S (EKHBX Units) for cooling mode
3 way valve
M3S (when EKHW is installed) selection sanitary-floorheating
Only for EKSOLHWAV1
User interface
3TW57786-7
2
6
• Altherma • Indoor units 61
2
7
• Indoor units • R-410A • EKHBH(X)016AB
7 Installation
7 - 1 Option necessity instruction
EKHBDP
Leaving water temperature limit to prevent condesation
Relative humidity 40%
Relative humidity 60%
Relative humidity 80%
Maximum leaving water temperature cooling mode
= 22°C
62
Example:
With ambient temperature of 25°C and relative humidity of 40%.
If leaving water temperature is below
12°C, condensation on water piping will happen.
Dry bulb temperature [°C]
1. Refer to psychometric chart for more information.
2. If condensation is expected, installation of EKHBDP - drainpan kit must be considered.
4TW57759-3
• Altherma • Indoor units
8
• Indoor units • R-410A • EKHBH(X)016AB
Operation range
EKHBH(X)016AB
ERHQ011-016AA
COOLING MODE outdoor temp (°CDB) outdoor temp (°CDB)
HEATING MODE
EKHW outdoor temp (°CDB) leaving evaporator water temperature (°C)
NO HEAT PUMP OPERATION
BACK UP HEATER ONLY leaving condensor water temperature (°C)
4TW57753-1A
DOMESTIC HOT MODE
2
8
BOOSTER HEATER
OPERATION ONLY
• Altherma • Indoor units water temperature sanitary tank (°C)
4TW57753-1A
63
2
9
• Indoor units • R-410A • EKHBH(X)016AB
9 Hydraulic performance
9 - 1 Static pressure drop unit
EKHBH(X)016
64
Flow [l/min] l high speed ll medium speed
ESP: external static pressure
Flow: waterflow through the unit
Warning:
1. Selecting a flow outside the curves can cause damage to or malfunction of the unit. See also minimum and maximum allowed water flowrange in the technical specifications.
2. Water quality must be according to EN directive EC 98/83 EC.
4TW57759-1
• Altherma • Indoor units
technical data
EEDEN08-720
Part 3/3:
EKHWS(U)
EKSOL
• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS
TABLE OF CONTENTS
EKHWS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Dimensional drawing & centre of gravity
. . . . . . . . . . . . . . . . . . . . . . . 71
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
• Altherma • Domestic hot water tank 67
o o h h c c a m s s e S h e e W H m K o E
1 Features
• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS
3
1
68 • Altherma • Domestic hot water tank
2
• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS
Specifications
S
2-1 TECHNICAL SPECIFICATIONS
Casing
Dimensions
Colour
Material
Packing
Weight
Packing
Unit
Unit
Packed Unit
Material
Height
Width
Depth
Height
Width
Depth mm mm kg kg mm mm mm mm
Main components
Tank
Main components
Weight
Tank
Insulation
Water volume
Material
Max. temperature
Max. water pressure
Material
Min. thickness l kg
°C bar mm
Heat exchanger
Quantity
Material
Booster heater Quantity
Capacity kW
Cable length m Temperature sensor
Piping connections
Water inlet H/E Diameter inch
Water outlet H/E Diameter inch
Cold water in Diameter
Hot water out Diameter inch inch
2-2 ELECTRICAL SPECIFICATIONS
Unit Power Supply Phase
Frequency Hz
Voltage V
Nominal running current A
Fuse Size
Phase
A
EKHWS150A
3V3
EKHWS200A
3V3
EKHWS300A
3V3
580
580
37
40
950
600
600
900
3
150
1,200
600
600
1,150
580
580
45
49
4
200
1,650
600
600
1,600
580
580
59
64
5
300
EKHWS200A
3Z2
EKHWS300A
3Z2
Neutral white
Epoxy-coated mild steel
1,200
600
1,650
600
600
1,150
580
580
45
49
600
1,600
580
580
59
64
EPS
Carton
4
200
5
300
EKHWSU150
A3V3
EKHWSU200
A3V3
EKHWSU300
A3V3
1,040
600
600
1,015
580
580
38
41
3
150
1,280
600
600
1,265
580
580
46
50
4
200
5
285
580
580
60
65
1,735
600
600
1,715
85 85 85
Stainless steel (DIN 1.4521)
85 85 85 85 85
10 10 10 10 10 10 10 10
40
1
1
3
12
40
1
1
3
12
40
1
1
3
12
Polyurethane foam
40 40
1 1
Duplex steel LDX 2101
1
3
12
1
3
12
3/4’’ FBSP
3/4’’ FBSP
3/4’’ FBSP
3/4’’ FBSP
40
1
1
3
12
40
1
1
3
12
EKHWS150A
3V3
1~
50
230
13
20
1~
EKHWS200A
3V3
1~
50
230
13
20
1~
EKHWS300A
3V3
1~
50
230
13
20
1~
EKHWS200A
3Z2
2~
50
400
7.5
20
2~
EKHWS300A
3Z2
2~
50
400
7.5
20
2~
EKHWSU150
A3V3
1~
50
230
13
20
1~
EKHWSU200
A3V3
1~
50
230
13
20
1~
EKHWSU300
A3V3
1~
50
230
13
20
1~
40
1
1
3
12
3
1
3
2
• Altherma • Domestic hot water tank 69
• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS
3
3
3 Capacity tables
3 - 1 Heating capacity tables
The ALTHERMA by Daikin heat-pump in combination with the optional domestic hot water tank provide hot water for household usage.
The below mentioned date allow a proper selection of the domestic hot water tank size for maximum comfort and efficiency.
(1) Sanitary hot water volume:
The volume of hot water available for domestic sanitary usage depends on the physical volume of the sanitary tank, on the sanitary water setpoint temperature and on the temperature spreading in the tank.
Therefor we define the equivalent hot water volume (EHWV).
Definition:
EHWV = the volume of hot water available for domestic sanitary usage at a temperature of 40°C.
40°C is considered a comfortable sanitary hot water temperature.
Tank
150L
200L
300L
Setpoint temp.
(°C)
55
65
75
55
65
75
55
65
75
EHWV (l)
110
150
175
160
200
240
295
385
435
Grade ++ Excessive availability of sanitary hot water.
-
+ Sufficient availability of sanitary hot water.
Temporary shortage of sanitary hot water can occur.
Modest
-
+
++
+
++
++
++
++
++
Usage pattern Modest Daily demand up tp 220 l -> typcial 2-persons usage pattern.
Medium Daily demand up to 325 l -> typical 3 to 4 persons usage pattern.
High Daily demand up to 550 l -> 4 to 6 persons usage pattern.
(2) Heat-up time:
Usage pattern
Medium
-
-
+
-
+
++
++
++
++
-
-
-
+
++
High
-
-
-
-
Definition:
Heat-up time The time required to reheat the domestic hot water tank to 55°C after tapping a certain volume of hot water at 40°C.
note: changing the field settings (see installation manual) can influence the heat-up time.
Tank
150L
200L
300L
Setpoint temp.
(°C)
55
55
55
Heat-up time for 150 L (bath)
<min>
60
60
50
Conditions for testing: Ta = 7°CDB / 6°CWB, Troom = 20°C, Tstart = 10°C, outdoor unit type: ERYQ007
Heat-up time for 50 L (shower)
<min>
45
40
30
(3) Efficiency of sanitary hot water production:
In the ALTHERMA by Daikin system both the heat-pump and the electric booster heater supply the energy to produce sanitary hot water.
The higher the portion of energy supplied by the heat-pump, the more energy efficient the system is.
Lowering the setpoint temperature increases the portion of energy supplied by the heat-pump and thus the efficiency of the system.
Definition:
Heat-pump portion Percentage of energy supplied by the heat-pump in the total energy need for sanitary hot water.
Conditions: Real life condition
Outdoor temperature
Room temperature
Outdoor unit type
Tank type
Field settings
Setpoint temp. (°C)
Simulation of a daily usage based upon ′medium′ usage pattern.
7°CDB / 6°CWB
20°CDB
ERYQ007
200l
Default field settings (see installation manual).
4TW57839-1
70 • Altherma • Domestic hot water tank
• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS
4 Dimensional drawing & centre of gravity
4 - 1 Dimensional drawing
EKHWS
Water mains in female 3/4’’ BSP
Water mains out female 3/4’’ BSP
Thermistor connection
Flow (from EKHB(H/X)*) female 3/4’’ BSP
Return (to EKHB(H/X)*) female 3/4’’ BSP
Switchbox
Thermal protector
Anode
Cable entry power, booster heater and thermal protection cable
Re-circulation connection female 3/4’’ BSP
Cable entry from EKHB(H/X)* (see EKSOLHWAV1)
Cable entry (to EKSOLHWAV1)
Thermistor connection (See EKSOLHWAV1)
Required service space around the tank
3
1
3
4
EKHWSU
3TW57834-1
Water connections
Water IN (cold)
Water OUT (hot)
Flow from EKHB(H/X)*
Return to EKHB(H/X)*
Temperature relief valve
22MM
3/4’’ female BSP
3/4’’ female BSP
3/4’’ female BSP
15MM
Thermistor connection
Thermistor connection (SeeEKSOLHWAV1) 1/2’’ female BSP
Re-circulation hole 3/4’’ female BSP
Water connections kit
Pressure reducing valve
Expansion relief valve
T-piece (to tundish)
Tundish
T-piece (to expansion vessel)
Adapter (expansion vessel)
Expansion vessel
Drain valve
Solenoid valve
22MM-22MM
22MM-22MM
15MM-15MM-1/2’’ female BSP
22MM-15MM
22MM-22MM-22MM
22MM-3/4’’ female BSP female BSP
22MM-3/4’’ hale BSP
3/4’’ female BSP-3/4’’ hale BSP
Other
Switchbox
Thermal protector 1+Thermostat
Cable entry power, booster heater, therminal protector
Cable entry power solenoid valve
Cable entry solenoid valve
Blind stop + 2 plastic screw-on closing caps for pressure reducing valve
Thermal protector 2+Thermostat
Cable entry (to EKSOLHWAV1)
Cable entry from EKHB(H/X)* (see EKSOLHWAV1)
Required service space
Model
EKHWSU150A3V3
EKHWSU200A3V3
EKHWSU300A3V3
H1
900
1150
1600
H2
1015
1265
1715
H3
255
410
410
H4
130
200
200
3TW57834-2
• Altherma • Domestic hot water tank 71
5
• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS
Piping diagram
3
5
EKHWSU
Outdoor
Field installation
(delivered with indoor unit)
Field supply
3-way motorized valve
Indoor Shut off valve
Shut off valve
Water return Water flow
Option domestic hot water tank
Water main OUT
Load
2-way solenoid valve
Option domestic hot water tank
Water main IN
T-piece
Drain valve
Tundish
Expansion vessel
T-piece
Expansion relief valve
Pressure reducing valve with integrated non return valve line strainer
Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe
*Field installation delivered with EKUHWA kit
RST
Y1S
M3S
Domestic hot water thermistor
Solenoid valve
3-way motorized valve
3TW57835-1
72 • Altherma • Domestic hot water tank
• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS
6 Wiring diagram
6 - 1 Wiring diagram
EKHWSU
EKHWSU**0A3V3
Water tank
Switch box
EKHB/X*
Switchbox
E4H
F2B
F2U
K3M
L
N
Q2T
Q2L
Q3L
X2M ∼X4M
X5M1
∼X7M
Y1S
: Booster heater
: Fuse booster heater
: Fuse 5A/250V
: Contactor booster heater
: Line
: Neutral
: Thermostat
Domestic hot water tank
: Thermostat protector domestic hot water tank
Thermal protector
Booster heater
: Terminal block
: Terminal block
: Solenoid valve
Notes:
1 This wiring diagram applies to the EKHWSU option
2 : Field wiring
: Field wiring
: Wire colour
: Terminal strip
: Protective earth
3 BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow
BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet
4 Please refer to the EKHWSU**DA3V3 option manual for more installation details.
3TW57836-1
3
6
3
1
• Altherma • Domestic hot water tank 73
3
7
7
• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS
Operation range
EKHW
DOMESTIC HOT MODE outdoor temp (°CDB)
BOOSTER HEATER
OPERATION ONLY water temperature sanitary tank (°C)
4TW57753-1A
74 • Altherma • Domestic hot water tank
• Solar Kit • SOLAR KIT • EKSOLHWAV1
TABLE OF CONTENTS
EKSOLHWAV1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Dimensional drawing & centre of gravity
. . . . . . . . . . . . . . . . . . . . . . . 78
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
• Altherma • Solar Kit 75
1 V K A a K W m H L e a a O h S K o o S E A S
1 Features
• Solar Kit • SOLAR KIT • EKSOLHWAV1
3
1
76 • Altherma • Solar Kit
2
• Solar Kit • SOLAR KIT • EKSOLHWAV1
Specifications
2-1 TECHNICAL SPECIFICATIONS
Dimensions
Weight
Packing
Heat
Exchanger
Packing
Unit
Height
Width
Depth
Height
Width
Depth
Unit
Packed Unit
Material
Weight kg
Type
Pressure drop Solar side kPa
Solar side °C Maximum inlet temperature
Capacity
Logarithmic mean temperature difference (LMTD)
W
K mm mm kg kg mm mm mm mm
Pump
Ambient temperature
Type
Number of speeds
Sound
Water circuit
Insulation material
Power input
Sound Pressure
W dBA
Piping connections diameter inch
Maximum
Minimum
°C
°C
2-2 ELECTRICAL SPECIFICATIONS
Unit Power Supply Phase
Frequency Hz
Voltage V
Voltage range Minimum
Maximum
Power Supply Intake
EKSOLHWAV1
305
270
8
9
795
340
295
770
Carton
1
Brazed plate
21.5
110
1,400
5 water cooled
3
46
27
3/4" FBSP
EPP
35
1
EKSOLHWAV1
1~
50
220-240
-10%
+10% indoor unit
3
3
2
• Altherma • Solar Kit 77
3
3
• Solar Kit • SOLAR KIT • EKSOLHWAV1
3 Dimensional drawing & centre of gravity
3 - 1 Dimensional drawing
EKSOLHWAV1 + EKHWS150* EKSOLHWAV1 + EKHWS200-300*
Detail 1 Detail 1
Switchbox domestic hot water tank
Cable entry (Altherma indoor unit)
Cable entry (Pump cable)
Components
Pump + switch for speed setting
Heat exchanger
EPP casing
Non return valves
Accessories (delivered with EKSOLHWAV1) Connection type
Thermistor sockel (thermistor solar pump station) (internal diameter
6.1mm)
Adapter
Adapter
Adapter
3/4 ″M BSP-3/4″M BSP
3/4 ″F BSP-3/4″M BSP
3/4 ″M BSP-3/4″M BSP
CONNECTIONS
Inlet connection from solar pump station
Return connection to solar pump station
Inlet connection from Altherma indoor unit
Return connection to Altherma indoor uint
EKSOLHWAV1 return connection to the domestic hot water tank heatexchanger
200-300l Tank 150l Tank
EKSOLHWAV1 inlet connection from the domestic hot water tank heatexchanger
3/4
3/4
3/4
3/4
3/4
3/4
″F BSP
″F BSP
″F BSP
″F BSP
″F BSP
″F BSP
Minimum space for service & ventilation
Detail 1
Scale: 1/4
Service space
Scale: 1/20
3TW57844-1
78 • Altherma • Solar Kit
• Solar Kit • SOLAR KIT • EKSOLHWAV1
3 Dimensional drawing & centre of gravity
3 - 1 Dimensional drawing
EKSOLHWAV1 + EKHWS150*
Detail 2
Scale: 1/4
EKSOLHWAV1 + EKHWS200-300*
Detail 2 Detail 1
Switchbox domestic hot water tank
Cable entry (Altherma indoor unit)
Cable entry (Pump cable)
Components
Pump + switch for speed setting
Heat exchanger
EPP casing
Non return valves
Accessories (delivered with EKSOLHWAV1)
3/4 ″F BSP
3/4 ″F BSP
3/4 ″F BSP
3/4 ″F BSP
3/4
3/4
″F BSP
″F BSP
EKUHWA Kit
Solenoid valve 3/4 ″F BSP-3/4″F BSP
Adapter 3/4 ″M BSP-3/4″M BSP
Solenoid valve
Connection type
Thermistor sockel (thermistor solar pump station) (internal diameter 6.1mm)
Adapter 3/4 ″M BSP-3/4″M BSP
Adapter (Field supply) 3/4 ″F BSP-3/4″M BSP
CONNECTIONS
Inlet connection from solar pump station
Return connection to solar pump station
Inlet connection from Altherma indoor unit
Return connection to Altherma indoor uint
EKSOLHWAV1 return connection to the domestic hot water tank heatexchanger
200-300l Tank j 150l Tank
EKSOLHWAV1 inlet connection from the domestic hot water tank heatexchanger
Minimum space for service & ventilation
Model H1
EKHWSU150* 430
EKHWSU200* 400
EKHWSU300* 400
Service space
Scale: 1/20
3TW57844-2
3
3
3
• Altherma • Solar Kit 79
4
• Solar Kit • SOLAR KIT • EKSOLHWAV1
Piping diagram
3
4
EKSOLHWAV1
Field installation
(delivered with indoor unit)
Field supply
3-way motorized valve
Outdoor Indoor
Field supply
Solar collector
Shut off valve
Shut off valve
Field supply
Solar pump station
Water from indoor
Medium from solar collector
Medium to solar collector
Option solar kit
Water to indoor
Check valve
Load
Water to tank
Option domestic hot water tank
Overview
Water from indoor
Medium from solar collector
Plate heat exchanger
Medium to solar collector
Flare connection
Water to indoor
Screw connection
Non return valve
Pump
Non return valve
Flange connection Pinched pipe
Detail 1
Water from tank
Water to tank
Detail 1
Only for EKHWSU*
2-way solenoid valve *
For EKHW(S/E)*
Spinned pipe
Water from tank
Y1S
M3S
Solenoid valve
3-way motorized valve
* Delivered with EKUHWA kit
3TW57845-1
80 • Altherma • Solar Kit
• Solar Kit • SOLAR KIT • EKSOLHWAV1
5 Wiring diagram
5 - 1 Wiring diagram
EKSOLHWAV1 with EKHWS*V3
EKHWS*V3
Switchbox
Solar pump
EKHB/X*
Switchbox
3
E4H
F2B
F2U
K3M
L
N
Q2T
Q2L
Q3L
Q3T
X2M ∼X4M
X5M1 ∼X7M
Y1S
: Booster heater
: Fuse booster heater
: Fuse 5A/250V
: Contactor booster heater
: Line
: Neutral
: Thermostat protector 1 domestic hot water tank
: Thermal protector
: Thermal protector 2
Booster heater
: Thermostat protector 2 domestic hot water tank
: Terminal block
: Terminal block
: Solenoid valve
EKSOLHWAV1 with EKHWS*Z2
EKHWS*Z2
Switchbox
EKHB/X*
Switchbox
Notes:
1 : Field wiring
: Field wiring
: Wire colour
: Terminal strip
: Protective earth
2 BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow
BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet
3 For more installation details please refer to the relevant installation manual.
3TW57846-1
EKHB/X*
Switchbox
Solar pump
3
5
E4H
F2B
F2U
K3M
L
N
Q2T
Q2L
Q3L
Q3T
X2M ∼X4M
X5M1 ∼X7M
Y1S
: Booster heater
: Fuse booster heater
: Fuse 5A/250V
: Contactor booster heater
: Line
: Neutral
: Thermostat protector 1 domestic hot water tank
: Thermal protector
: Thermal protector 2
Booster heater
: Thermostat protector 2 domestic hot water tank
: Terminal block
: Terminal block
: Solenoid valve
EKHB/X*
Switchbox
Notes:
1 : Field wiring
: Field wiring
: Wire colour
: Terminal strip
: Protective earth
2 BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow
BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet
3 For more installation details please refer to the relevant installation manual.
3TW57846-1
• Altherma • Solar Kit 81
3
5
• Solar Kit • SOLAR KIT • EKSOLHWAV1
5 Wiring diagram
5 - 1 Wiring diagram
EKSOLHWAV1 with EKHWSU
EKHWS*V3
Switchbox
EKUHWA
EKHB/X*
Switchbox
EKSOLHWAV1
EKHB/X*
Switchbox
Notes:
1 : Field wiring
: Field wiring
: Wire colour
: Terminal strip
: Protective earth
2 BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow
BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet
3 For more installation details please refer to the relevant installation manual.
E4H
F2B
F2U
K3M
L
N
Q2T
Q2L
Q3L
Q3T
X2M ∼X4M
X5M1
∼X7M
Y1S
: Booster heater
: Fuse booster heater
: Fuse 5A/250V
: Contactor booster heater
: Line
: Neutral
: Thermostat protector 1 domestic hot water tank
: Thermal protector
: Thermal protector 2
Booster heater
: Thermostat protector 2 domestic hot water tank
: Terminal block
: Terminal block
: Solenoid valve
3TW57846-1
82 • Altherma • Solar Kit
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project