- Computers & electronics
- Networking
- Network switches
- Extron electronic
- DVS 150
- Operating instructions
advertisement
DVS 100 and DVS150
Digital Video Scalers
68-459-01
Printed in USA
Precautions
Safety Instructions • English
This symbol is intended to alert the user of important operating and maintenance
(servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
Caution
Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future reference.
Follow Warnings • Follow all warnings and instructions marked on the equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not recommended by the equipment manufacturer because they may be hazardous.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel contient des instructions importantes concernant l’exploitation et la maintenance
(réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de
tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de sécurité et d’exploitation avant d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de pouvoir les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et consignes marqués sur le matériel ou présentés dans la documentation utilisateur.
Eviter les pièces de fixation • Ne pas utiliser de pièces de fixation ni d’outils non recommandés par le fabricant du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen
Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung
(Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des
Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden, sollten Sie alle Sicherheits-und
Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte, die nicht ausdrücklich vom
Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Warning
Power sources • This equipment should be operated only from the power source indicated on the product. This equipment is intended to be used with a main power system with a grounded
(neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all power cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-serviceable parts inside. To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are provided to prevent overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced. Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger, déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-maintenance par un technicien qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orifices • Si le boîtier de l’appareil comporte des fentes ou des orifices, ceux-ci servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais
être bloquées par des objets.
Lithium Batterie • Il a danger d'explosion s'll y a remplacment incorrect de la batterie. Remplacer uniquement avec une batterie du meme type ou d'un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen, sollten Sie alle
Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifiziertem Servicepersonal durchgeführt werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist, dienen diese zur Vermeidung einer Überhitzung der empfindlichen Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird. Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den
Herstelleranweisungen.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean destacar en el contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de operación y seguridad, antes de usar el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones marcadas en el equipo o en la documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no sean especificamente recomendados por el fabricante, ya que podrian implicar riesgos.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la acometida de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal calificado. En el interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento, es para evitar el sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante.
Desachar las baterías usadas siguiendo las instrucciones del fabricante.
Quick Start — DVS 100 and DVS 150
Installation
Step 1
Install the four rubber feet on the bottom of the scaler (1A), or mount the scaler in a rack (1B).
Step 2
Turn off power to the input and output devices, and unplug their power cords.
Step 3
Attach the scaler to the input devices.
Input options (3) are:
Composite video (input 1)
Component video (input 2)
S-video (input 3)
RGB pass-thru (input 4; DVS 150 only)
Step 4
Attach the scaler to the output devices.
Output options (4) are:
RGsB (connected to R, G, and B)
RGBS (connected to R, G, B, and S)
RGBHV (connected to R, G, B, H, and V)
VGA/XGA/SVGA/SXGA
(connected to RGB output connector)
Step 5
Plug the scaler, input device, and output device into a grounded AC source, and turn on the input and output devices.
Step 6
Use the LCD menu screens to configure the scaler (see the next page).
3
VID
B-Y
1
R-Y Y
2
Composite Video
(Input 1)
3
False front panel uses 2 front holes
INP
UT
1
2
3
LO
R
TIN
T
BR
IT
CO
NTR
AST
H S
HIFT
V S
HIFT
RAT
E
DIG
ITA
L V
DV
S 1
CA
00
1A
Rubber feet bottom side
(4 plcs) or
(2) 4-40 x 1/8" screws
1B
Use 2 mounting holes on opposite corners
Input/Output Devices
DVS 100
100-240V 0.1A
VID
INPUTS
B-Y
1
R-Y Y
S-VIDEO
2
50/60 Hz 3
RGB OUT
OUTPUTS
R
H
G
V
B
S
REMOTE or
RS-232 Control or
DVD Player
HDTV Plasma DLP Projector CRT Projector
Laserdisc Player
OUTPUT
DSS Receiver
INPUT
DVS 150
100-240 VAC .3A MAX
VIDEO
INPUTS
B-Y R
OUTPUTS
G
1
R-Y
Y
S-VIDEO
RGB
PASS-THRU
H V
2 3 4
50/60 Hz
B
S
REMOTE
RGB
DLP Projector
DVD Player or
DLP Projector or
RS-232 Control
Laserdisc Player
DSS Receiver
Laptop
Computer
INPUT
HDTV Plasma LCD Projector
OUTPUT
CRT Projector
VID
B-Y
1
R-Y Y
2 3
Component Video
(Input 2)
VID
B-Y
1
R-Y Y
S-video
(Input 3)
2 3
RGB
Pass-Thru
(Input 4; DVS 150 only)
4
R
H
RGsB
V
G B
S
R G
H V
RGBS
B
S
R G
H V
RGBHV
B
S
RGB Output
Quick Start — DVS 100 and DVS 150, cont’d
Configuring the Scaler
Configuring the scaler: Press the input and rate buttons simultaneously, and hold them for two seconds.
Stepping through the LCD display menus: Press the input selection button.
Changing a selection: Turn the adjustment knob while the menu is displayed.
Exiting the menus: Press the input selection button while the Detail menu is displayed, or don’t press any buttons or turn any knobs for eight seconds.
AUTOSW — Choose whether the DVS automatically selects the active input.
On : The DVS selects the active input automatically. Off: You select the input manually.
TOPBLANK — Add or remove additional blanking lines at the top of the image.
BOTBLANK — Add or remove additional blanking lines at the bottom of the image.
H-SYNC — Change the polarity of the horizontal sync signal to allow any projector to distinguish the
DVS 100 or DVS 150 input from a standard RGB input.
+ : Sets the horizontal sync polarity to positive. -: Sets the horizontal sync polarity to negative.
V-SYNC — Change the polarity of the vertical sync signal to allow any projector to distinguish the
DVS 100 or DVS 150 input from a standard RGB input.
+ : Sets the vertical sync polarity to positive. -: Sets the vertical sync polarity to negative.
SOG — Set the sync output format.
Yes : Sync on green (RGsB) output. No: RGBS or RGBHV output (based on unit cabling).
STILL — Enhance output for still or motion video.
On : Enhanced image for still video and text. Off: Enhanced image for motion video.
DETAIL — Apply a filter to improve image detail.
1 : Low level of detail. 2: Medium level of detail. 3: High level of detail.
Operation
Choosing the input source: Press the input selection button until the desired input LED lights.
If input 4 (RGB pass-through) of the DVS 150 is selected, you cannot make any of the following adjustments.
Adjusting the image: Press the button for the adjustment, and rotate the adjustment knob until the desired result is achieved.
Choosing the output rate: Press and hold the rate button for two seconds, and then rotate the adjustment knob until the desired rate appears in the LCD display. Options are:
640x480 (VGA), 60/75 Hz 848x480 (plasma), 60 Hz 1280x768 (plasma), 56 Hz 480p (HDTV)
800x600 (SVGA), 60/75 Hz 852x480 (plasma), 60/75 Hz 1280x1024 (SXGA), 60 Hz 720p (HDTV)
832x624 (Mac), 60/75 Hz 1024x768 (XGA), 60/75 Hz 1360x765 (plasma), 60 Hz 1080p (HDTV)
Activating freeze mode: Issue the RS-232 freeze mode command.
Deactivating freeze mode: Press the input selection button or issue an RS-232 command.
Restoring default picture control settings (active input): Press and hold the input selection button for two seconds.
Restoring all settings to factory defaults: Press and hold the input selection button while attaching the AC power cord.
Table of Contents
Chapter 1 • Introduction
.......................................................................................... 1-1
About the Scaler
.................................................................................................... 1-2
Features
..................................................................................................................... 1-2
Chapter 2 • Installation
............................................................................................. 2-1
Rear Panel Features
.............................................................................................. 2-2
Installation
............................................................................................................... 2-3
Overview .............................................................................................................. 2-3
Mounting the scaler ............................................................................................ 2-3
Installing the rubber feet .................................................................................... 2-4
Cabling ................................................................................................................. 2-5
Front Panel Features
............................................................................................. 2-6
Configuring the Scaler
......................................................................................... 2-6
Configuration settings ........................................................................................ 2-7
Chapter 3 • Operation
................................................................................................ 3-1
Front Panel Operations
........................................................................................ 3-2
Default screens .................................................................................................... 3-2
Choosing the input source .................................................................................. 3-2
Adjusting an image ............................................................................................. 3-2
Choosing the output rate ................................................................................... 3-3
Freeze mode ........................................................................................................ 3-4
Executive mode ................................................................................................... 3-4
Resetting the scaler ............................................................................................. 3-4
Channel reset
System reset
.................................................................................................. 3-4
.................................................................................................... 3-5
Chapter 4 • Serial Communication
..................................................................... 4-1
RS-232 Programmer’s Guide
.............................................................................. 4-3
DVS initiated messages ....................................................................................... 4-3
DVS error response .............................................................................................. 4-3
Using the command/response table ................................................................... 4-3
Command/response table ................................................................................... 4-4
Remote Contact Closure Operation
................................................................ 4-3
Control Software for Windows
........................................................................ 4-5
Installing the Software ........................................................................................ 4-5
Using the Software .............................................................................................. 4-6
DVS 100 and DVS 150 Table of Contents
1-
i
Table of Contents, cont’d
Chapter 5 • Troubleshooting
.................................................................................. 5-1
Operating Problems
.............................................................................................. 5-2
Appendix A • Specifications
.................................................................................. A-1
Appendix B • Reference Information
................................................................ B-1
Part Numbers
.......................................................................................................... B-2
DVS 100 and DVS 150 part numbers .................................................................. B-2
Related part numbers ......................................................................................... B-2
BNC cables ........................................................................................................... B-2
Glossary
..................................................................................................................... B-3
68-459-01 C
Printed in the USA
04 00
ii DVS 100 and DVS 150 Table of Contents
DVS 100 and DVS 150
1
Introduction
About the Scaler
Features
About the Scaler
Each DVS 100 and DVS 150 digital video scaler allows analog video signals (composite video, S-video, and component video) to be displayed on a device with a fixed resolution and aspect ratio, such as an
LCD (liquid crystal display) projector, DLP (digital light processing) projector, or plasma display.
DVS 150 includes a 15-pin HD RGB pass-through connector for RGB input. Video signals coming into the scaler from this connector are not scaled. Instead, they are passed directly to the ouputs.
Features
• Autosave — Automatically stores adjustments and uses the control settings associated with the selected input.
• Autoswitch mode — Automatically selects the active input device. If more than one input device is on, the device with the highest video quality is selected.
• Blanking — Allows noise or unwanted information, such as tape head switching and closed captioning, to be eliminated from the top and bottom of the display.
• Dual output connectors — Allow you to connect and run two output devices simultaneously.
• Executive mode — Locks out all front-panel image adjustment functions except input selection. When executive mode is active, all image adjustments are available through RS-232 commands.
• Freeze mode — Locks the output display to the current image.
• Inputs — Includes three BNC connectors for component video, one
BNC connector for composite video, and one 4-pin mini-DIN connector for S-video. The DVS 150 also includes one 15-pin HD connector for RGB pass-through input.
• Multiple control methods — Allow you to make adjustments by pressing a button on the front panel, choosing options from a menu, sending an RS-232 command from a computer, or using a remote contact closure control.
• Outputs — Outputs video as RGB, RGsB, RGBS, and RGBHV. BNC connectors and a 15-pin HD connector are provided.
1-2 DVS 100 and DVS 150 Introduction
• Output resolutions — Supports the following output resolutions:
• 640 x 480 (VGA) at 60 or 75 Hz (Hertz)
• 800 x 600 (SVGA) at 60 or 75 Hz
• 832 x 624 (Macintosh) at 60 or 75 Hz
• 848 x 480 (plasma) at 60 Hz
• 852 x 480 (plasma) at 60 or 75 Hz
• 1024 x 768 (XGA) at 60 or 75 Hz
• 1280 x 768 (plasma) at 56 Hz
• 1280 x 1024 (SXGA) at 60 Hz
• 1360 x 765 (plasma) at 60 Hz
• 480p (HDTV)
• 720p (HDTV)
• 1080p (HDTV)
• Power supply — Includes an internal, 100-240VAC, 50/60 Hz, autoswitchable power supply.
• Precise image processing — Provides the latest in motion compensation, which produces motion images that are free of “jaggies”; a three-
line adaptive comb filter, which eliminates chroma crawl; and a quad
standard decoder, which ensures compatibility with NTSC (National
Television Standards Committee) 3.58, NTSC 4.43, SECAM
(sequential couleur avec mémoire), and PAL (phase alternate line) video standards.
• Software-based configuration — Allows you to configure the scaler through menu controls, simplifying installation.
• Switchable sync polarities — Allow you to manually set the horizontal and vertical sync polarities, to allow the output device to store DVS input as a unique input.
DVS 100 and DVS 150 Introduction 1-3
Introduction, cont’d
1-4 DVS 100 and DVS 150 Introduction
DVS 100 and DVS 150
2
Installation
Rear Panel Features
Installation
Front Panel Features
Configuring the Scaler
Rear Panel Features
100-240V 0.3A
VIDEO
INPUTS
B-Y
50/60 Hz
1
R-Y Y
S-VIDEO
2 3
RGB
OUTPUTS
R
H
G
V
B
REMOTE
S
1 2 3 4 5
Figure 1 — DVS 100 rear panel
6 7
7
REMOTE 100-240V 0.3A
VIDEO
1
R-Y
INPUTS
B-Y
Y
S-VIDEO
2 3
RGB
4
R
OUTPUTS
G
H V
B
S
RGB
50/60 Hz
1 2 3 4 8
Figure 2 — DVS 150 rear panel
1
2
3
4
5
6
7
8
6 5
AC power connector — Standard AC power connector attaches the scaler to any power source from 100VAC to 240VAC, operating at 50 Hz or 60 Hz.
Composite video input connector — One BNC female connector for composite video input.
Component video input connectors — Three BNC female connectors for component (R-Y, B-Y, Y) video input.
S-video input connector — One 4-pin mini-DIN female connector for S-video input.
RGB output connector — One 15-pin HD female RGB connector for the output projector.
You can install and run two output devices simultaneously, one using BNC connectors, and the other using the RGB connector.
Output connectors — BNC female connectors for RGsB (sync on green), RGBS (composite sync), or RGBHV output.
RS-232/contact closure remote connector — One 9-pin D female connector that allows you to attach a computer or another device, such as a keypad or other contact closure device, for remote control of the scaler.
RGB pass-thru connector (DVS 150 only) — One 15-pin HD female RGB connector for input. The signal from the input device is passed through to the output connectors without being scaled.
2-2 DVS 100 and DVS 150 Installation
Installation
Overview
To install and set up the DVS 100 or DVS 150, follow these basic steps:
1
2
3
4
5
6
7
If desired, mount the scaler in a rack (see “Mounting the scaler” below). Otherwise, install the rubber feet (see “Installing the rubber feet” on page 2-4).
Turn off power to the input and output devices, and unplug the power cables from them.
Attach the scaler to the input devices and the output devices. See
“Cabling” on page 2-5.
Plug the scaler, input devices, and output devices into a grounded
AC source.
Turn on the input and output devices.
Use the LCD menu screens to configure the scaler. See
“Configuring the Scaler” on page 2-7.
The image from the input device should appear on the output device. If it does not, double check steps 3 and 4 and make adjustments as needed, and then see “Operating Problems” on page 5-2.
Mounting the scaler
Each DVS 100 and DVS 150 ships with four uninstalled rubber feet. If you are going to rack mount the unit, do so before cabling it, and do not install the rubber feet. If you are not rack mounting the scaler, skip to
“Installing the rubber feet” on page 2-4.
The DVS 100 or DVS 150 can be rack mounted using one side of an optional 19” 1U Universal Rack Shelf (Extron part # 60-190-01).
To rack mount the scaler, do the following:
1.
If rubber feet were previously installed on the bottom of the case, remove them.
2.
Mount the scaler on the rack shelf as shown in figure 3. Use two
4-40 x 1/8” screws in opposite (diagonal) corners to secure the case to the shelf.
DVS 100 and DVS 150 Installation 2-3
Installation, cont’d
False front panel uses 2 front holes
INP
UT
1
2
3
CO
LO
R
TIN
T
BR
IT
CO
NTR
AST
H S
HIFT
V S
HIFT
DIG
ITA
L V
DVS 100
IDE
O S
CA
LE
R
(2) 4-40 x 1/8" Screws
Use 2 mounting holes on opposite corners
Figure 3 — Mounting the scaler
Installing the rubber feet
The scaler ships with four uninstalled rubber feet. Install the rubber feet only if you are not rack mounting the scaler. To install the rubber feet, do the following:
1.
Turn the scaler upside down and place it on a flat surface.
2.
Remove the protective backing from a rubber foot.
3.
Place the rubber foot on one corner of the scaler as shown in figure
4, and press it into place.
Position the rubber foot carefully before pressing it into place. It is difficult to move the foot after it is in place.
IN
PU
T
1
2
3
CO
R
TIN
T
CO
NTR
AST
H S
HIF
T
V S
HIF
T
RAT
E
DIG
ITA
L V
ID
DVS 100
EO
S
CA
LE
R
Rubber Feet
Bottom Side (4 Plcs)
Figure 4 — Installing the rubber feet
4.
Repeat steps 2 and 3 to install a rubber foot on each of the remaining corners of the scaler.
5.
Turn the scaler right side up and place it in the desired location.
2-4 DVS 100 and DVS 150 Installation
Cabling
The scaler can connect to input devices that produce composite video,
S-video, or component video, and to output devices, such as LCD projectors, DLP displays, or plasma displays. The DVS 150 can also connect to input devices that produce RGB video via the RGB passthrough connector.
To cable the scaler, complete the following steps. Use figure 5 as a general guide.
DVS 100
100-240V 0.1A
VID
INPUTS
B-Y
1
R-Y Y
S-VIDEO
2
50/60 Hz 3
RGB OUT
OUTPUTS
R
H
G
V
B
REMOTE
S or
RS-232 Control or
DVD Player
HDTV Plasma DLP Projector CRT Projector
Laserdisc Player
OUTPUT
DSS Receiver
INPUT
DVS 150
100-240 VAC .3A MAX
VIDEO
INPUTS
B-Y R
OUTPUTS
G
1
R-Y Y
S-VIDEO
H V
50/60 Hz 2 3 4
S
B
REMOTE
RGB
DLP Projector
RS-232 Control
DLP Projector
DVD Player or or
Laserdisc Player
DSS Receiver
Laptop
Computer
INPUT
HDTV Plasma
Figure 5 — Cabling the scaler
LCD Projector
OUTPUT
CRT Projector
1.
Attach the input device (or devices) to the scaler. Figure 6 shows each of the connection options.
VID VID VID
B-Y B-Y B-Y
1
R-Y
1
R-Y
1
R-Y Y Y Y
2
Composite Video
(Input 1)
3 2 3
Component Video
(Input 2)
S-video
(Input 3)
2 3 RGB
Pass-Thru
(Input 4; DVS 150 only)
Figure 6 — Input connections
You can attach up to three input devices, one each of composite video, S-video, and component video. You can also connect an
RGB input device, for pass-through to the output, to the DVS 150.
You can select among the input sources via the input selection switch on the front panel.
If there is no video input, the LCD displays “No Source”.
2.
Use BNC connectors or a 15-pin HD connector to connect the scaler to the output device. Figure 7 shows each of the connection options.
R G B R G
H V S H V
RGsB RGBS
Figure 7 — Output connections
S
B R G
H V
RGBHV
B
S
RGB Output
DVS 100 and DVS 150 Installation 2-5
Installation, cont’d
If you cable the scaler for sync on green (RGsB or SOG) output, you must also configure the scaler for SOG via the configuration menu. See “Configuring the Scaler” on page 2-7 for instructions.
You can install and run two output devices simultaneously, one using BNC connectors, and the other using the RGB connector.
Front Panel Features
1
INPUT
1
2
3
COLOR TINT BRIGHT CONT H SHIFT V SHIFT RATE
DVS 100
DIGITAL VIDEO SCALER
2 3 4 5 6 7 8 9 10 11
Figure 8 — DVS 100 front panel
1
INPUT
3
4
1
2
COLOR TINT BRIGHT CONT H SHIFT V SHIFT RATE
DVS 150
DIGITAL VIDEO SCALER
2 3 4 5 6 7 8 9 10 11
Figure 9 — DVS 150 front panel
1
2
3
4
5
6
LCD — Displays configuration menus and status information.
See “Configuring the Scaler” on page 2-7 and “Adjusting an image” on page 3-2.
Input selection button — Allows you to select the input type (see
“Choosing the input source” on page 3-2). If the image has been frozen via an RS-232 command, the input button cancels the freeze function (see “Freeze mode” on page 3-4).
Input LEDs — Display the active input. If LED (light emitting diode) 1 is lit, the input is composite video. If LED 2 is lit, the input is component video. If LED 3 is lit, the input is S-video. If
LED 4 is lit , the input is RGB (from the pass-though connector;
DVS 150 only).
The following adjustments are not available if the input is RGB pass-through (DVS 150 only).
Color control button — Allows you to adjust the image color. For more information, see “Adjusting an image” on page 3-2.
Tint control button — Allows you to adjust the image tint. For more information, see “Adjusting an image” on page 3-2. This control is not available if the input is component video, PAL, or
SECAM.
Brightness control button — Allows you to adjust the image brightness. For more information, see “Adjusting an image” on page 3-2.
2-6 DVS 100 and DVS 150 Installation
7
8
9
10
11
Contrast control button — Allows you to adjust the image contrast. For more information, see “Adjusting an image” on page 3-2.
Horizontal shift control button — Allows you to adjust the horizontal shift. For more information, see “Adjusting an image” on page 3-2.
Vertical shift control button — Allows you to adjust the vertical shift. For more information, see “Adjusting an image” on page 3-2.
Output rate control button — Allows you to choose the output rate. For more information, see “Choosing the output rate” on page 3-3.
Adjustment knob — With a control button selected, allows you to make adjustments to the feature controlled by the button. For example, if the horizontal shift control button is selected, turning the adjustment knob moves the image to the right or left.
Configuring the Scaler
The LCD on the front panel of the scaler provides access to a menu that allows you to configure the scaler. To access the menu, press the input selection button and the rate button simultaneously, and hold them for two seconds. The Autoswitch menu appears in the LCD.
To step through the menus, press the input selection button.
To exit the menu, step through the menus until the Detail menu appears, and then press the input selection button one more time. Or, wait eight seconds without pressing any buttons or turning the adjust knob, and the menu reverts to the default screens.
Configuration settings
Autoswitch (AUTOSW) — If set to On, automatically selects the input source that uses the highest video quality. If set to Off, allows you to manually specify the input source by pressing the input button on the front panel. To toggle between On and Off, turn the adjustment knob while the Autoswitch menu is displayed. By default, autoswitch mode is Off.
Top blanking (TOPBLANK) — Removes noise and unwanted information, such as tape head switching and closed captions, from the top of the screen. To change the top blanking level, turn the adjustment knob while the Top blanking menu is displayed, until the unwanted information no longer appears.
Bottom blanking (BOTBLANK) — Removes noise and unwanted information, such as tape head switching and closed captions, from the bottom of the screen. To change the bottom blanking level, turn the adjustment knob while the Bottom blanking menu is displayed, until the unwanted information no longer appears.
Horizontal sync polarity (H-SYNC) — Changes the polarity of the horizontal sync signal to allow any projector to distinguish the scaler input from a standard RGB input. To toggle between
Positive and Negative, turn the adjustment knob while the
Horizontal sync menu is displayed. By default, the horizontal sync polarity is set to Negative.
DVS 100 and DVS 150 Installation 2-7
Installation, cont’d
Vertical sync polarity (V-SYNC) — Changes the polarity of the vertical sync signal to allow any projector to distinguish the DVS 100 input from a standard RGB input. To toggle between Positive and
Negative, turn the adjustment knob while the Vertical sync menu is displayed. By default, the vertical sync polarity is set to
Negative.
Sync on green (SOG) — If set to Yes, provides sync on green (RGsB or
SOG) output. If set to No, provides RGBS or RGBHV output, depending on the attached cables. To toggle between Yes and No, turn the adjustment knob while the Sync on green menu is displayed. By default, Sync on green is set to No.
Still (STILL) — If set to On, provides enhanced resolution for easier viewing of text and other motionless video. If set to Off, provides optimized motion video. To toggle between On and Off, turn the adjustment knob while the Still menu is displayed. By default, still mode is set to Off.
Detail (DETAIL) — Applies a filter to improve the image’s level of detail. To switch between 1 (low), 2 (medium), and 3 (high), turn the adjustment knob while the Detail menu is displayed. By default, detail mode is set to 3.
2-8 DVS 100 and DVS 150 Installation
DVS 100 and DVS 150
3
Operation
Front Panel Operations
Front Panel Operations
The front panel includes an LCD screen that displays the current status of the scaler and the scan rate of the current video input signal. You can also use controls on the front panel to control the image display.
Diagrams of the front panels are shown on page 2-6.
Default screens
By default, the LCD toggles between two screens every four seconds.
One screen displays the product name, and the other shows the output resolution and frequency (figure 10 shows an example).
EXTRON
DVS 100
1280 X
1024 @60
Figure 10 — Default screens
If no input signal is present, the LCD backlight turns off and the LCD toggles between screens similar to those shown in figure 11.
EXTRON
DVS 100
No
Source
Figure 11 — No signal present
Choosing the input source
To choose an input source, press the input selection button to toggle through the inputs. The LED corresponding to the selected input lights:
• Input LED 1 — Composite video
• Input LED 2 — Component video
• Input LED 3 — S-video
• Input LED 4 — RGB pass-through video (DVS 150 only)
When the button is released, the input changes and the LCD shows the current input and signal type (see figure 12). The message appears for
8 seconds, and then changes back to the default screens.
INPUT 1
CMPOSITE
INPUT 2
COMPNENT
Figure 12 — Current input screens
INPUT 3
S-VIDEO
INPUT 4
RGB
If an RS-232 command was issued to activate the freeze function, to change the input source you must press the input selection button twice. The first press unfreezes the image, and the second changes the input source.
Adjusting an image
The front panel controls allow you to make adjustments to the displayed image.
To make an adjustment, do the following:
1.
Push the control button that corresponds to the adjustment you want to make. The LED above the pressed button lights, and, depending on the selected button, the LCD displays the current level value for the adjustment.
2.
Turn the adjustment knob until the desired adjustment is accomplished. The LCD returns to the default screens, and the adjusted value is saved for future use by the active input, if you
3-2 DVS 100 and DVS 150 Operation
press the same button again or if you stop turning the knob for eight seconds.
If an image control reaches its minimum, maximum, or default level, the
LCD displays a screen similar to the screens shown in figure 13.
COLOR
Min
COLOR
Max
COLOR
Default
Figure 13 — Minimum, maximum, and default value screens
If input 4 (RGB pass-through) of the DVS 150 is selected, you cannot adjust the image through the scaler.
Color control button — Adjusts the color intensity.
Tint control button — Adjusts the amount of tint displayed. This adjustment is not available if the input is component video, PAL, or SECAM.
Brightness control button — Adjusts the amount or intensity of video light produced on the screen, without regard to color.
Contrast control button — Adjusts the range of light and dark values in a picture, or the ratio between the maximum and the minimum brightness values.
Horizontal shift control button — Shifts the image to the left and right.
Vertical shift control button — Shifts the image up and down.
Choosing the output rate
If input 4 (RGB pass-through) of the DVS 150 is selected, you cannot change the output rate through the scaler.
To choose the output rate, do the following:
1.
Refer to the documentation that accompanied the display device to determine its native mode (or sweet spot).
2.
Press and hold the rate button on the scaler for two seconds. The
LED above the button lights, and the LCD displays the current output resolution and frequency.
3.
Turn the adjustment knob until the desired output rate appears in the LCD and the image is displayed at the correct rate.
Available rates are:
•
•
640 x 480, 60 Hz
800 x 600, 60 Hz
•
•
640 x 480, 75 Hz
800 x 600, 75 Hz
• 832 x 624, 75 Hz
•
•
•
•
832 x 624, 60 Hz
848 x 480, 60 Hz
852 x 480, 60 Hz
1024 x 768, 60 Hz
•
•
•
852 x 480, 75 Hz
1024 x 768, 75 Hz
1280 x 1024, 60 Hz
•
•
•
•
•
1280 x 768, 56 Hz
1360 x 765, 60 Hz
HDTV 480p
HDTV 720p
HDTV 1080p
DVS 100 and DVS 150 Operation 3-3
Operation, cont’d
Freeze mode
Freeze mode locks the output display to the current image. Freeze mode can be activated only by issuing an RS-232 command
IMAGE
FROZEN
(see chapter 4 for more information). If freeze mode is activated, the LCD screen displays the message displayed at the left.
If input 4 (RGB pass-through) of the DVS 150 is selected, you cannot activate freeze mode.
You can deactivate freeze mode in the following ways:
• By issuing another RS-232 command
• By pressing the input selection button
• Automatically, if the scaler is in autoswitch mode and the input source changes.
Executive mode
Executive mode limits the number of operations available from the front panel. This is useful for situations in which many end users operate the scaler, and you want to prevent them from changing the adjustments you have made.
To enable executive mode, press the horizontal shift and vertical shift
X-MODE
ENABLED control buttons simultaneously for two seconds. The
LCD displays the message at the left for eight seconds, and then changes back to the default screens.
When executive mode is enabled, the only front panel button that can be used is the input selection button. If any other button is pressed, the
LCD displays the same message for eight seconds, then changes back to the default screens.
To disable executive mode, press the horizontal shift and vertical shift control buttons simultaneously for two seconds. The
X-MODE
DISABLED
LCD displays the message at the left for eight seconds, then changes back to the default screens.
Resetting the scaler
You can perform two types of reset:
• Channel reset restores the factory default picture control settings (color, tint, brightness, contrast, horizontal shift, and vertical shift) for only the currently selected input.
If input 4 (RGB pass-through) of the DVS 150 is selected, you cannot perform a channel reset.
• System reset restores all factory default settings, including all picture controls for all inputs, the output rate, and all configuration options available from the LCD menu.
Channel reset
To perform a channel reset, press and hold the input selection button for two seconds. The picture control settings for the
INPUT 1
RESET active input are reset to their factory default settings.
The LCD displays a message similar to the one at the left for four seconds, and then changes back to the default screens.
3-4 DVS 100 and DVS 150 Operation
System reset
To perform a system reset, press and hold the input selection button while attaching the AC power cord. The picture
SYSTEM
RESET control settings for all input sources, the output rates, and the configuration options are reset to their factory default settings. The LCD displays the message at the left for four seconds, and then changes back to the default screens.
DVS 100 and DVS 150 Operation 3-5
Operation, cont’d
3-6 DVS 100 and DVS 150 Operation
DVS 100 and DVS 150
4
Serial Communication
RS-232 Programmer’s Guide
Remote Contact Closure Operation
Control Software for Windows
The scaler’s RS-232 connector can be connected to the serial port output of a host device such as a computer or control system. This connection makes software control of the scaler possible. Figure 14 shows a scaler
RS-232 connection to a host serial port connector.
OUTPUTS
R
H
G
V
B
REMOTE
S
DVS 100
RS-232
Control Cable
Computer Control
RS-232
Control Cable
R
OUTPUTS
G
H V
B
S
REMOTE
RGB
Computer Control
DVS 150
Figure 14 — Scaler RS-232 to host connection
The RS-232 connector on the scaler is a 9-pin D female connector with the following pin assignments:
Pin Description
1
2
3
Input 1 select*
Transmit data
Receive data
6
7
4
5
Input 2 select*
Signal ground
Input 3 select*
Input 4 select* (DVS 150 only)
8
9
Not used
Not used
* Used for remote contact closure control
The protocol is 9600 baud, 8-bit, 1 stop bit, no parity, and no flow control.
The DVS 100 or DVS 150 scaler accepts SIS™ (Simple Instruction Set™) commands through the RS-232 port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each scaler response to an SIS command ends with a carriage return and a line feed
(CR/LF = ), which signals the end of the response character string. (A string is one or more characters.)
4-2
DVS 100 and DVS 150 Serial Communication
RS-232 Programmer’s Guide
DVS initiated messages
When a local event occurs, such as a front panel operation, the scaler responds by sending a message to the host. The DVS-initiated messages are listed below (underlined).
(C) Copyright 1999, Extron Electronics, DVS xxx, Vx.x
The copyright message is initiated by the scaler when it is first powered on. DVS xxx is the scaler model, and Vx.xx is the firmware version number.
Reconfig
The Reconfig message is initiated by the scaler when a new input is selected or when any image adjustment is made.
The scaler does not expect a response from the host, but, for example, the host program might request a new status.
DVS error response
When the scaler receives an SIS command and determines that it is valid, it performs the command and sends a response back to the host device. If the scaler is unable to perform the command because the command is invalid or contains invalid parameters, the scaler returns an error response to the host. The error response codes are:
E01 — Invalid input channel number (too large)
E09 — Invalid function number (too large)
E10 — Invalid command
E13 — Invalid value (out of range)
Using the command/response table
The command/response table is shown on the next page. Lower case characters are acceptable in the command field only where indicated.
Symbols are used throughout the table to represent variables in the command/response fields. Symbol definitions are shown at the beginning of the table, as is an ASCII-to-hexadecimal (HEX) conversion table. Command and response examples are shown throughout the table.
Screen adjustment commands are not available if input 4 is selected
(DVS 150 only).
Remote Contact Closure Operation
The RS-232 connector provides a way to control the scaler from a remote contact closure device. This is made possible by using pins that are not normally used by the RS-232 interface. The contact closure pin assignments are shown in the table on page 4-2.
To select a different input number through the RS-232 connector, momentarily short the pin for the desired input number (#) to the signal ground (pin 5). To force one of the inputs to be selected continuously, leave the short to signal ground in place. This will override any front panel input selection.
DVS 100 and DVS 150 Serial Communication
4-3
Serial Communication, cont’d
Color
Specific value
Increment up
Increment down
Tint
Specific value
Increment up
Increment down
Contrast
Specific value
Increment up
Increment down
Brightness
Specific value
Increment up
Increment down
Horizontal shift
Specific value
Increment up
Increment down
Command/response table
Symbol definitions: = CR/LF, • = space
= Inputs = 1 = Composite
2 = Component
3 = S-video
4 = RGB (DVS 150 only)
= Adjustment range 1-127
= Output rate = 1 = 640x480 @ 60 Hz
2 = 640x480 @ 75 Hz
3 = 800x600 @ 60 Hz
4 = 800x600 @ 75 Hz
5 = 832x624 @ 60 Hz
6 = 832x624 @ 75 Hz
7 = 852x480 @ 60 Hz
8 = 852x480 @ 75 Hz
9 = 1024x768 @ 60 Hz
10 = 1024x768 @ 75 Hz
11 = 1280x1024 @ 60 Hz
12 = 480p
13 = 720p
14 = 1080p
15 = 848x480 @ 60 Hz
16 = 1280x768 @ 56 Hz
17 = 1360x765 @ 60 Hz
ASCII to HEX Conversion Table
= 1 = on, 0 = off
= Input type
= Detail level
•
0 = None
1 = NTSC 3.58
2 = PAL
3 = NTSC 4.43
4 = SECAM
1 = Low
2 = Medium
3 = High
COMMAND
Input selection
ASCII RESPONSE DESCRIPTION
!
C Sets input source
{ C
} C
C
{ T
} T
T
{ ^
} ^
^
{ Y
Y
} Y
{H
}H
H
Col
Col
Col
Tin
Tin
Tin
Con
Con
Con
Brt
Brt
Brt
Hph
Hph+
Hph–
Selects color
Selects next higher color value
Selects next lower color value
Selects tint
Selects next higher tint value
Selects next lower tint value
Selects contrast
Selects next higher contrast value
Selects next lower contrast value
Selects brightness
Selects next higher brightness value
Selects next lower brightness value
Selects horizontal shift
Shift image right one step
Shift image left one step
4-4
DVS 100 and DVS 150 Serial Communication
COMMAND
Vertical shift
Specific value
Increment up
Increment down
Set output rate
ASCII
{/
}/
/
RESPONSE
Vph
Vph+
Vph–
DESCRIPTION
Selects vertical shift
Shift image up one step
Shift image down one step
= Rte Set the video output rate
Freeze
Enable
Disable
Executive mode
Enable
Disable f
F
X x
Frz 1
Frz Ø
Exe 1
Exe Ø
Set freeze mode to On (freeze current displayed image)
Set freeze mode to Off
Set executive mode to On
Set executive mode to Off
Query software version q
Q
Still mode
#
Detail mode
D
(Same as Q below)
Ver x.xx
Example response: Ver 1.23
Stl Sets still mode On or Off
Det Sets detail mode to level 1 (low), 2, or 3 (high)
Request part number n
N
(Same as N below)
N6Ø-3Ø4-Ø1 Displays the Extron part number: 60-304-01 is DVS 100, and 60-317-01 is DVS 150
Request information* i
I
(Same as I below)
C •Col •Tin •Con •Brt •Hph •Vph •Rte •Frz
•Exe •Typ •Stl •Det
* Typ displays the type of input video signal as automatically sensed by the scaler. You cannot change this entry.
Control Software for Windows
The Signal Enhancement Products Control Program (part # 29-017-01), which is used by the scalers, is compatible with Windows 3.1, 3.11, 95/
98, and NT. It provides remote control of scaler settings. For DVS 100, use version 3.1 or later; for DVS 150, use version 3.2 or later.
Installing the software
The program is contained on a single 3.5-inch diskette, and it can run from the floppy drive. However, it is usually more convenient to load and run the program from the hard drive.
To install the software from the floppy disk onto the hard drive, run
SETUP.EXE from the floppy disk, and follow the instructions that appear on the screen. The program occupies approximately 1 MB (megabyte) of hard-drive space.
By default, the Windows installation creates a C:\S_ENHANC directory, and it places two icons (Signal Enhancement Products Control Pgm and
Signal Enhancement Products Help) into a group or folder named
“Extron Electronics”.
DVS 100 and DVS 150 Serial Communication
4-5
Serial Communication, cont’d
Using the software
1.
To run the Signal Enhancement Products Control Program, doubleclick on the Signal Enhancement Products Control
Pgm icon in the Extron Electronics group or folder.
The Comm menu appears on the screen.
2.
Click on the comm port that is connected to the scaler’s RS-232 port.
The Extron Signal Enhancement Products Control Program window appears. It displays the current settings and input type detected (see figure 15).
78
58 70 42 89 63
Figure 15 — Signal Enhancement Products Control Program
3.
Using normal Windows controls, you can perform the same adjustments as from the front panel.
For information about program features, you can access the Help program in any of the following ways:
• From the Extron Electronics program folder or group, double-click on the Signal Enhancement Products Help icon.
• From within the Signal Enhancement Products Control Program, click on the Help menu on the main screen.
• From within the Signal Enhancement Products Control Program, press the F1 key.
4-6
DVS 100 and DVS 150 Serial Communication
DVS 100 and DVS 150
5
Troubleshooting
Operating Problems
This section gives recommendations on what to do if you have problems operating the DVS 100 or DVS 150, and it provides examples and descriptions for some image problems you might encounter.
Following are some tips to help you in troubleshooting.
1. Some symptoms may resemble others, so you may want to look through all of the examples before attacking the problem.
2. Be prepared to backtrack in case the action taken doesn’t solve the problem.
3. It may help to keep notes and sketches in case the troubleshooting process gets lengthy. This will also give you something to discuss if you call for technical support.
4. Try simplifying the system by eliminating components that may have introduced the problem or made it more complicated.
5. For sync-related problems: Portable digital projectors are designed to operate close to the video source. Sync problems may result from using long cables or from improper termination. A sync adapter, such as Extron’s ASTA (active sync termination adapter), may help solve these problems.
6. For LCD and DLP projectors and plasma displays: In addition to the sync-related information above, check the user’s manual that came with the projector for troubleshooting tips, as well as for settings and adjustments. Each manufacturer may have its own terms, so look for terms like “auto setup”, “auto sync”, “pixel phase”, and “tracking”.
Operating Problems
The table below shows some common operating problems and their solutions.
Problem
No image appears.
Cause
The input signal is incompatible.
Solution
Attach an input device that is compatible with NTSC 3.58,
NTSC 4.43, PAL, or SECAM.
Deactivate freeze mode
(page 3-4).
The image is frozen.
The image is flashing.
Inputs cannot be switched.
Freeze mode was entered when the image was black.
The scaled output rate is too high for the display.
Freeze mode is on.
The scaled output rate is too high for the display.
Autoswitch is turned on.
Change the scaled output to a compatible resolution
(page 3-3).
Deactivate freeze mode
(page 3-4). If that does not work, unplug the power cord from the scaler, then plug it back in.
Change the scaled output to a compatible resolution
(page 3-3).
Turn off autoswitch (page 2-7).
5-2 DVS 100 and DVS 150 Troubleshooting
Problem Cause
Picture controls Input 4 is selected are not active.
(DVS 150 only).
The image is green.
The unit is configured for sync on green.
The image is too soft.
Solution
Switch to input 1–3. Input 4 is pass-through only (page 1-2).
Turn off sync on green
(page 2-8).
The detail level Change the detail level needs to be changed. (page 2-8).
DVS 100 and DVS 150 Troubleshooting 5-3
Troubleshooting, cont’d
5-4 DVS 100 and DVS 150 Troubleshooting
DVS 100 and DVS 150
A
Specifications
Specifications
Video input
Number/type ............................... 1 composite video, 1 S-video, 1 component video (R-Y, B-Y, Y);
1 RGB pass-through (DVS 150 only)
Connectors .................................... 3 BNC female .......................... component video
1 4-pin mini-DIN female ...... S-video
1 BNC female .......................... composite video
1 15-pin HD female ............... RGB pass-through (DVS 150 only)
Nominal level(s) .......................... Analog — 0.7V to 1.0V p-p
Impedance .................................... 75 ohms
Vertical frequency ....................... 50 Hz to 60 Hz
Video output
Number/type/format ................ 1 scaled RGBHV, RGBS, RGsB
1 scaled VGA RGBHV
Connectors .................................... 6 BNC female ..................... RGB output
1 15-pin HD female .......... RGBHV output
Nominal level ............................... 0.7V p-p
Impedance .................................... 75 ohms
Vertical frequency ....................... 56 Hz, 60 Hz, or 75 Hz
Scaled VGA resolution ............... 640x480, 800x600, 832x624, 840x480, 852x480, 1024x768, 1280x768, 1280x1024,
1360x765, HDTV 480P, 720P, and 1080P
Sync
Output type .................................. RGBHV, RGBS, RGsB
Standards ...................................... NTSC 3.58, NTSC 4.43, PAL, SECAM
Output level ................................. TTL — 5.0V p-p
Output impedance ...................... 75 ohms
Polarity .......................................... Positive or negative (switch-selectable)
Control/Remote — decoder/scaler
Serial control port ....................... RS-232, 9-pin female D connector
Baud rate and protocol ............... 9600, 8-bit, 1 stop bit, no parity
Pin configurations ....................... 1 = input 1 select
2 = TX
3 = RX
4 = input 2 select
5 = GND
6 = input 3 select
7 = input 4 select (DVS 150 only)
Contact closure ............................ 9-pin female D connector
Program control ........................... Extron’s control program for Windows®
Extron’s SIS™ (Simple Instruction Set™)
General
Power ............................................ 100VAC to 240VAC, 50/60 Hz, 30 Watts, internal, auto-switchable
Temperature/humidity ............. Storage -40° to +158°F (-40° to +70°C) / 10% to 90%, non-condensing
Operating +32° to +122°F (0° to +50°C) / 10% to 90%, non-condensing
Rack mount .................................. Yes, with optional rack shelf, part #60-190-01
Enclosure type ............................. Metal
Enclosure dimensions ................ 1.75" H x 8.75" W x 9.50" D
4.45 cm H x 22.22 cm W x 24.13 cm D
Shipping weight .......................... 6 lbs (2.7 kg)
Vibration ....................................... NSTA 1A in carton (National Safe Transit Association)
Approvals ..................................... UL, CUL, CE, FCC Class B
MTBF ............................................. 30,000 hours
Warranty ....................................... 2 years parts and labor
Specifications are subject to change without notice.
A-2 DVS 100 and DVS 150 Specifications
DVS 100 and DVS 150
B
Reference Information
Part Numbers
Glossary
Part Numbers
DVS 100 and DVS 150 part numbers
Extron Part
DVS 100
DVS 150
Signal Enhancement Products Control Program
DVS 100 and DVS 150 User’s Manual
S-video cable, 6’
Part #
60-304-01
60-317-01
29-017-01
68-459-01
26-316-02
Related part numbers
Extron Part
Universal rack shelf
Part #
60-190-01
BNC cables
Extron SHR BNC cables are super-high resolution cables. Extron recommends using high-resolution BNC cables for signals with scan frequencies of 15 — 125 kHz to achieve maximum performance.
Bulk cable
Extron Part
SHR bulk cable
Bulk SHR-1, 500’
Bulk SHR-1, 1000’
Bulk SHR-4, 500’
Bulk SHR-5, 500’
BNC SHR crimp connectors, qty. 50
BNC-4 Mini-HR Bulk Cable
Bulk BNC 4-500’ HR
Bulk BNC 4-1000’ HR
BNC 5 Mini-HR Bulk Cable
Bulk BNC 5-500’ HR
Bulk BNC 5-1000’ HR
BNC 5 Plenum Mini-HR B
ULK
Cable
Bulk BNC 5-500’ HRP
Bulk BNC 5-1000’ HRP
Install Plenum Bulk Cable
Bulk Install Plenum, 500’
Bulk Install Plenum, 1000’
Assorted connectors
BNC Connectors
BNC Mini-HR crimp connectors, qty. 50
BNC SHR crimp connectors, qty. 50
BNC Bulkhead connectors, qty. 50
(for custom wall plates)
Part #
22-098-02
22-098-03
22-099-02
22-100-02
100-075-51
22-032-02
22-032-03
22-020-02
22-020-03
22-103-02
22-103-03
22-111-03
22-111-04
100-074-51
100-075-51
100-076-51
B-2 DVS 100 and DVS 150 Reference Information
Pre-cut cables
BNC-4 HR cable is used for RGBS cable runs, and BNC-5 is used for
RGBHV cable runs. Either type can also be used for RGsB (sync on green). All Extron BNC cables have male gender connectors at both ends. A plenum version of the BNC-5 HR cable is also available.
BNC-4 HR Cable
BNC-4-25’ HR (25 feet/7.5 meters)
BNC-4-50’ HR (50 feet/15.0 meters)
BNC-4-75’ HR (75 feet/23.0 meters)
BNC-4-100’ HR (100 feet/30.0 meters)
BNC-4-150’ HR (150 feet/45.0 meters)
BNC-4-200’ HR (200 feet/60.0 meters)
BNC-4-250’ HR (250 feet/75.0 meters)
BNC-4-300’ HR (300 feet/90.0 meters)
BNC-5 HR Cable
BNC-5-25’ HR (25 feet/7.5 meters)
BNC-5-50’ HR (50 feet/15.0 meters)
BNC-5-75’ HR (75 feet/23.0 meters)
BNC-5-100’ HR (100 feet/30.0 meters)
BNC-5-150’ HR (150 feet/45.0 meters)
BNC-5-200’ HR (200 feet/60.0 meters)
BNC-5-250’ HR (250 feet/75.0 meters)
BNC-5-300’ HR (300 feet/90.0 meters)
26-210-04
26-210-05
26-210-06
26-210-07
26-210-08
26-210-09
26-210-54
26-210-53
26-260-03
26-260-04
26-260-16
26-260-05
26-260-12
26-260-06
26-260-18
26-260-14
Bulk cable in lengths up to 5000’ rolls is available with or without connectors.
Glossary
Autoswitch mode — Automatically selects the active input device. If more than one input device is on, the device with the highest video quality is selected.
Blanking, top and bottom — A feature that removes noise and unwanted information, such as tape head switching and closed captioning, from the top and bottom portions of the screen.
Channel reset — Reconfigures the settings for the active input to the original factory settings.
Detail filter — Controls the sampling of the horizontal plane, thereby affecting the sharpness or smoothness of the scaled image.
Digital video scaler — See scaler.
Executive mode — Locks out all front panel functions except input selection.
Freeze — Locks the output display to the current image.
Motion compensation — Eliminates scan lines and “jaggies” in motion video.
Precise image processing — A combination of three technologies
(motion compensation, three-line adaptive comb filter, and quad standard decoder) that produces the best possible upscaled image.
Quad standard decoder — A device, compatible with the NTSC 3.58,
NTSC 4.43, SECAM, and PAL standards, that separates the RGBS
(red, green, blue, and sync) signals from a composite, S-video, or component video signal.
DVS 100 and DVS 150 Reference Information B-3
Reference Information, cont’d
Scaling — Changes the size of an image without changing its shape.
Scaling can be used when the image size does not fit the display device. A digital video scaler converts an NTSC, PAL, or SECAM image to a size that can be displayed on a device with a fixed resolution and aspect ratio, such as an LCD (liquid crystal display) projectors, DLP (digital light processing) projectors, or plasma projector .
Sync polarity — A circuit can be designed to operate on the positivegoing or negative-going part of the sync pulse. The DVS 100 and
DVS 150 have menu options that allow you to select which edge
(positive or negative) to trigger on.
System reset — Reconfigures all DVS 100 settings to the original factory settings.
Three-line adaptive comb filter — A filter circuit that passes a series of frequencies and rejects the frequencies in between, producing a frequency response that resembles the teeth of a comb. Its precise separation of the chroma and luma signals reduces both cross chroma and cross luma artifacts (chroma crawl or “zipper” artifacts). It preserves more detail in the black-and-white, resulting in a better quality picture. Although comb filters are successful in reducing artifacts, they may also cause a certain amount of loss of resolution in the picture. Each DVS 100 and
DVS 150 uses a three-line adaptive comb filter, which examines three scan lines instead of one, producing a picture of higher quality than one produced by a standard comb filter.
B-4 DVS 100 and DVS 150 Reference Information
FCC Class B Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance.
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of two years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South
America, Central
America, and Asia:
Europe, Africa, and the
Middle East:
Extron Electronics
1230 South Lewis Street
Anaheim, CA 92805, U.S.A.
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions or non-Extron authorized modification to the product.
If it has been determined that the product is defective, please call Extron and ask for an Applications
Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), or 65.226.0015 (Asia) to receive an RA# (Return
Authorization number). This will begin the repair process as quickly as possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
EXTRON ELECTRONICS/RGB SYSTEMS, INC.
1230 South Lewis Street, Anaheim, CA 92805
800.633.9876 714.491.1500 FAX 714.491.1517
U.S.A.
EXTRON ELECTRONICS, EUROPE
Beeldschermweg 6C, 3821 AH Amersfoort
+31.33.453.4040 FAX +31.33.453.4050
The Netherlands
EXTRON ELECTRONICS, ASIA
41B Kreta Ayer Road, Singapore 089003
+65.226.0015 FAX +65.226.0019
Singapore
EXTRON ELECTRONIC INFORMATION
E
XTRON
WEB™: www.extron.com
E XTRON FAX™: 714.491.0192
24-hour access—worldwide!
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 13 Overview
- 13 Mounting the scaler
- 13 Installing the rubber feet
- 13 Cabling
- 13 Configuration settings
- 14 Default screens
- 14 Choosing the input source
- 14 Adjusting an image
- 14 Choosing the output rate
- 14 Freeze mode
- 14 Executive mode
- 14 Resetting the scaler
- 15 DVS initiated messages
- 15 DVS error response
- 15 Using the command/response table
- 15 Command/response table
- 15 Installing the Software
- 15 Using the Software