Ceiling Split Cooling System
Installation, Operation & Care Manual
WM-2500SSD WM-4500SSD
WM-6500SSD WM-8500SSD w w w .
.
v i i n o t t e m p .
.
c o m
R e a d a n d s a v e t t h e s e i i n s s t t r r u c t t i i o n s s
Important Safety Information
WARNING:
• Do not use a ground fault interrupter (GFI).
• A dedicated 20 AMP circuit for WM-2500~4500SSD and 30 AMP for WM-
6500~8500SSD are required.
Table of Contents
Cellar Construction.…………………………….……………..3
Features & Specifications…………………….….…………..4
Temperature & Humidity……….…………..………..……….6
Care Guide…………………………………………………….10
User’ Troubleshooting…….………………………………...11
Installer’s Instructions………….…..….……..…………….15
Electrical Wirings..…………….…..….……..………………26
Customer Support……………………………………………30
Warranty……………………………………………………….31
Cellar Construction
This is only a guide and shall be considered as minimum requirements.
All interior walls and floors shall have a vapor barrier and a minimum of R13 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall be installed on the warm side of the insulation. All joints, door frames, electrical outlets or switches and any pipes or vents that go through the cellar shall be sealed to prevent air and moisture leakage into the cellar. Concrete, rock, and brick are not insulation or vapor barriers.
Doors shall be of a minimum size, insulated to at least R13 and tightly sealed with high quality weather stripping. Be sure to seal the bottom of the door and fill gap between the door’s frame and wall before installing the cap molding.
In order to maintain 55 °F in the wine cellar, the ambient temperature surrounding the enclosure shall not exceed the temperature of the cellar by more than 25 °F. No cellar wall shall receive direct sun or strong wind.
Lighting shall be of low wattage, with a timer to insure lights are not left on when the cellar is not occupied.
The cooling system will not be able to maintain the proper temperature if fresh moisture-laden air is constantly being introduced to the cellar. Symptoms of this condition are; cooling unit runs all the time with only a slight reduction in temperature and/or water overflows from the unit. Because of the temperature difference between the inside and outside, very small cracks can allow large amounts of outside air to enter into the cellar. Please be aware that moisture can pass through solid concrete, paint and wood. Often a newly constructed cellar contains fresh wood, paint, concrete and other building materials. These materials contain large amounts of moisture. When placed into operation in this type of environment, the system will work harder to remove this extra moisture resulting in increased “run” time.
Features and Specifications
• Wine-Mate ceiling mount split cooling systems WM-2500~8500SSD are designed and used to provide a cold temperature between 50~65 °F for a properly insulated wine cellar.
• The wine cellar will maintain humidity range within 50~70% RH.
• These temperature and humidity ranges like in natural caves are optimized for long term storage of wine.
• SSD units consist of a condensing unit and an evaporator unit; they are connected by a liquid line and an insulated suction line.
• SSD condensing units can be located away from the wine cellars 50 ft so that noise and compressor vibration are isolated.
• SSD evaporator units provide two way air supply operation. The evaporator units can be installed on the ceiling in the center of a wine cellar.
Fig. 1 SSD Ceiling Split Cooling System
NOTE:
Capacity is determined under the cellar, the cellar ambient and the
condensing unit ambient temperatures of 55°F, 75°F and 90°F, with R13 interior and R19 exterior insulations. Any higher ambient temperatures, lower insulations will cause reducing capacity and the cellar temperature
may not be maintained at 55°F.
CAUTION:
If the installation area will be below 50°F, purchase a low ambient condition kit.
WM-
2500SSD
WM-
4500SSD
WM-
6500SSD
NOTE:
To prepare rough-in, leave minimum 4” clearances for electrical wiring and refrigeration piping.
The specifications and dimensions are listed as follows:
Model No
Evap Unit
WE”xDE”xHE”
WM-25SFCD
23x17.5x7.5
WM-45SFCD
23x17.5x10.5
WM-65SFCD
29.875x21x11.75
Cond Unit
L”xD”xH”
WM-250SCU
18x14 x12
WM-450SCU
18x14 x12
WM-650SCU
24x18 x18
Btu/h
CFM
2500
350
4500
460
6500
660
Cellar Size
(cu ft)
Refrigerant
250 R134a
1000 R134a
1500 R134a
Electrical
Evap Unit/
Cond Unit
115V-60HZ-1A
115V-60HZ-5.7A
115V-60HZ-1A
115V-60HZ-6.9A
115V-60HZ-1.5A
115V-60HZ-12A
Weight (lb)
Evap Unit/
Cond Unit
20/40
25/60
35/90
WM-
8500SSD
WM-85SFCD
29.875x21x13.5
WM-850SCU
24x18 x18
8500
810
2000 R134a
115V-60HZ-1.5A
115V-60HZ-15A
40/115
Also see Fig. 3, 4, 5 & 6 for further info.
1. The controller
Temperature and Humidity
Fig. 2 TEMPERATURE CONTROLLER
1) Keys
SET: To display set-point; in programming mode it selects a parameter or confirms an operation.
: To start a manual defrost.
: To see the maximum stored temperature; in programming mode it browses the parameter codes or increases the displayed value.
: To see the minimum stored temperature; in programming mode it browses the parameter codes or decreases the displayed value.
: To turn on/off the power to the unit.
+ : To lock/unlock the keypad.
SET+ : To enter in the programming mode.
SET+ : To return to the temperature display.
2) Lock and unlock the keys
To lock the keys, press up + down keys + until POF is displayed; to unlock the keys, press up + down keys + until PON is displayed.
3) Display
During normal operating conditions, the display shows the value measured by the air temperature probe. In case of active alarm, the temperature flashes alternately to the code alarm. The LED functions are listed as follows.
LED MODE
ON
FUNCTION
Compressor enabled
Flashing
ON
ON
Anti-short cycle enabled
Defrost cycle enabled
Fan enabled
Flashing
ON
ON
Flashing
Fan delay after defrost enabled
Alarm occurring
Temperature measuring unit
Programming mode
4) Alarm Signals
The alarm codes are described as follows.
MESSAGE CAUSE
P1
FUNCTION
Temperature probe faulty Compressor switching to Con and CoF
HA
LA
High temperature alarm
Low temperature alarm
Probe temperature ALU higher than the setting temperature; Outputs unchanged
Probe temperature ALL lower than the setting temperature; Outputs unchanged
CA External alarm All outputs off
Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation.
Check connections before replacing the probe. Temperature alarms “HA”, “LA” automatically stops as soon as the temperature returns to normal value. Alarm
“CA” (with i1F=PAL) recovers only by switching off and on the instrument.
2. Temperature Setting
• Set the temperature at 55
°
F for the optimum aging of wine
• On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature.
• Allow 24 hours to stabilize the temperature for each new temperature setting operation
3. How to see temperature set-point
1) Press and immediately release the SET key, the display will show the set-point value.
2) Press again and immediately release the SET key to display the probe value.
4. How to change the set-point
1) Press and hold the SET key until the “°C” or “°F” LED starts flashing and the set-point is displayed.
2) Press the up/down keys / to change the set-point value within 10 sec.
3) Press the SET key again to store the new set-point value.
NOTE: The unit turns on at set-point Set plus regulation differential Hy after antishort cycle AC has elapsed; the unit turns off at set-point Set.
5. Manual Defrost
Press and hold the defrost key until defrost starts. The defrost indicator will be on.
US idF
MdF
ALC
ALU
ALL
Hy
AC
Con
CoF
CF rES dLy ot
LS
6. Parameter Programming
1) Press and hold the SET + keys until the “°C” or “°F” LED starts flashing, then release the keys.
2) Press and hold again the SET + keys until the Pr2 label is displayed, then release the keys. The first parameter Hy will be displayed.
3) Press up/down keys / to scroll to the required parameter within 10 sec.
4) Press the “SET” key to display its value.
5) Use up/down keys to change its value within 10 sec.
6) Press “SET” to store the new value and the display will flash 3 times.
7) To exit: Press SET + or wait 15sec without pressing a key.
PARAMETER DESCRIPTION
Set set-point ( ° ) 55 temperature regulation differential ( ° ) 4 anti-short cycle delay (min) 10 compress on with probe faulty (min) 15 compress off with probe faulty (min) 30 temperature unit ( °F/ °C ) display resolution temperature display delay (min) probe calibration ( ° )
F: Fahrenheit in: integer
1
0
AFH
ALd dAO
SAA minimum set-point ( ° ) maximum set-point ( ° ) high temperature alarm ( ° ) low temperature alarm ( ° ) alarm recovery differential ( ° ) temperature alarm delay (min) temperature alarm delay on startup (hr) heater set-point ( ° )
50
65 defrost cycle interval time (hour) 12 defrost cycle endurance time (min) 30 temperature alarm type rE: relative to set-point
10
10
5
60
23
40
SHy heater regulation differential ( ° ) 4
FSU
FnC
Fon
FoF fan action fan operating mode
Std
C-n: on with compressor & off during defrost fan on with compressor off (min) 0 fan off with compressor off (min) 15
NOTE: Depending on the controller, not all parameters are used.
7. How to calibrate the air probe
If the actual cellar temperature differs from the setting temperature, set parameter ot = actual cellar temperature minus set-point.
8. How to adjust defrost cycle
I n case there is excessive frost, the parameters FnC = C-y, idF = 4 and MdF =
20 can be used to avoid frost.
9. How to adjust the humidity
The parameter Fon is used to adjust the humidity in the wine cellar. Higher Fon results in higher relative humidity.
Use a separate hygrometer to monitor the humidity.
10. How to set alarm call
1) S peech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the set-point Set.
2) In order to test the call function, set parameters Ald = 0 and dAO = 0. After testing, set Ald = 60 and dAO = 23.
11. How to set low cellar temperature heater
The heater turns on at SAA minus Shy; the heater turns off at SAA.
NOTES:
• Use a forced air heater to warm up the wine cellar.
• If there is a thermostat on the heater, bypass it or set the thermostat at the highest level.
If the heater runs more than 10 A current, use a 120VAC coil contactor.
Care Guide
In general, always unplug system or disconnect power while doing care.
1. Coil Cleaning
• Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months.
• Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty.
2. Condensate Removing
• Remove the excessive condensate if it is accumulated in the wine cellar at high humidity conditions.
User’s Troubleshooting
This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive.
1. Unit not running
2. Unit not starting , but temperature rising high
Response a. Power cord not plugged b. No power from supply c. Incorrect or loose wirings a. Check power cord b. Check receptacle and fuses c. Check all wirings and connections d. Contact an authorized electrician e. Setting higher than ambient temperature f. Waiting for cut-in f. Wait g. Unit is under defrost mode h. Compressor light blinking a. Anti-short cycle h. Unit is under anti-short cycle delay i. Call service for diagnosis a. Reset AC
3. Temperature fluctuating a. Air probe a. When using an air probe, the wine bottle temperature is mainly controlled by the average air temperature. If the set-point is 55 ° F with the differential 4F, the cooling unit turns on at 59 ° F of air temperature (It may be higher than
59 ° F if it is in anti-short cycle or defrost cycle) and turns off at 55 ° F of air temperature. The average air temperature is 57 ° F, and then the wine temperature is around 57+/-
0.5
° F. The air is light enough to change so quickly that it maintains relatively constant average temperature that would prevent wine bottle temperature from fluctuating.
4. Temperature high, unit stopping and starting normally
5. Temperature high, unit stopping and starting with short evaporator coil, displaying temperature ok b. Air probe in cold-air supply, displaying temperature ok evaporator b. Move the air probe away from the cold-air supply c. Failed controller and probe c. Call service for diagnosis running time
6. Temperature a. Improper cellar insulation & seal a. Check insulation, gasket and door opening
high or not cooling and running continually b. Cellar too large c. Ambient temperature too high f. Evaporator or condenser airflow b. Check for excessive size c. Check installation location d. Leave minimum 3 feet clearance for the hot air exhaust side and leave minimum 1 foot clearance for the ambient air intake side e. Check for both evaporator and condenser fans f. Check for air restrictions, air shortcirculation, grille directions h. Defrost and reset temperature k. Undercharge or overcharge
7. Unit running
too long
8. Condenser fan running but compressor
not running
9. Compressor running but condenser fan not
running
10.Temperature high, compressor stopping and starting but very short running time
11.Evaporator fan running too long
12. Evaporator a. Improper cellar insulation & seal b. Exhaust restricted c. Cellar too large d. Ambient temperature > 90
°
F e. Dirty Condenser f. Improper condenser air flow a. Incorrect or loose wirings compressor a. Fan blade stuck b. Incorrect or loose wirings d. Fan cycle control l. Check compressor windings, start relay and overload protector a. Check insulation, gasket and door opening b. Leave minimum 3 feet clearance for the hot air exhaust side and leave minimum 1 foot clearance for the ambient air intake side c. Check for excessive size d. Check for installation location e. Clean condenser f. Check for fan and air short circulation a. Check all wirings and connections b. Check start relay, start capacitor, overload protector, compressor. d. Overcharge of refrigerant e. Discharge or suction pressure too high d. Call service for removing refrigerant e. Call service for information a. Incorrect or loose wirings a. Check for proper clearance b. Check all wirings d. Check for setting a. Check compressor windings, start relay and overload protector. b. Check for condenser fan
Post-compressor fan running a. Reset FON mode for humidity modulation a. Check all wirings and connections
fan running but b. Check start relay, start capacitor, overload protector, compressor. condensing unit not
running
13.Temperature low
14.Evaporator
freezing up
15.Water leak
16.Excessive condensate in wine
cellar
17.Condensate inside ducts
18.Condensate outside ducts
19.Circuit
tripping a. Low temperature setting b. Low ambient temperature c. Air probe fault d. Temperature controller fault a. Evaporator air flow restriction a. Raise the setting b. Move to another location c. Check probe connections or change a new one d. Change a new one a. Check for fans and CFM b. Condenser air flow restriction c. Not stopping due to air leak, high ambient temperature or low temperature setting b. Check for fans and CFM c. Check for seal, door opening, ambient temperature and temperature setting d. Defective controller or probe e. Low ambient temperature f. Initially working then stopping, moisture in the system d. Check for controller and probe e. Change defrost cycle g. Refrigerant low or leaking h. Expansion valve blockage g. Call service h. Call service a. Air leak in the wine cellar causing excessive condensate b. High humidity causing excessive condensate c. Evaporator air flow restriction d. Drain restricted or unit not level, and water overflowing e. Drip tray leak (No water overflow but leak) a. Air leak in the wine cellar causing excessive condensate b. High humidity causing excessive condensate c. Drain restricted a. Drain line restricted b. Continually running not stopping c. Too cold supply air a. Duct not insulated b. High humidity c. Too cold supply air a. Incorrect fuse or breaker a. Check for air leak b. Use drain line c. Check supply air flow or air TD d. Clean the drip tray and drain line e. Seal the leak using silicone sealant a. Check for any air leak b. Use drain line c. Clean the drip tray and drain line a. Check for drain increase defrost cycle temperature setting a. Check for insulation temperature setting a. Check for proper fuse or breaker b. Check for wirings and connections
20.Noisy
operation a. Mounting area not firm a. Add support to improve installation c. Compressor overloaded due to washers, tubing contact and loose screws. c. Check for airflow
high ambient temperatures or airflow restriction d. Call service for checking internal loose, inadequate lubrication and incorrect wirings
Installer’s Instructions
Federal law requires that WINE-MATE split cooling systems be installed by an EPA certified refrigeration technician.
1. General Instructions
WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed the system. Proper installation is critical. Vinotemp can only warrant the quality of the components.
The installation and proper operation of the system must be warranted by the installer. Installation of the system must be done in accordance with all state and local building and electrical codes.
The condensing unit and evaporator unit are connected by a liquid line and an insulated suction line that are supplied by the installer. These lines must be properly sized for the distance between the two units. After the units and lines are connected, the system must be checked for restriction, pressurization and leak. Then the system must be evacuate and charged with refrigerant.
Refrigerant amount will vary depending on the length of line set.
Parts included:
Evaporator Unit (liquid line solenoid valve and expansion valve installed)
Condensing Unit (discharge and suction valves installed)
Liquid Filter
Liquid Indicator
Temperature Controller (4.5”LX4.5”WX3.75”D) + Air Probe
Parts not included:
Liquid line copper tubing
Suction line copper tubing
CAUTION:
Liquid and suction line locations may differ from what are shown here, please check on the units for proper installation.
Fig. 3 WM-25~45SFCD Evaporator Unit
Fig. 4 WM-65~85SFCD Evaporator Unit
Fig. 5 WM-250~450SCU Condensing Unit
Fig. 6 WM-650~850SCU Condensing Unit
Fig. 7 Liquid Filter Fig. 8 Liquid Indicator
Fig. 9 Temperature Controller (4.25”L X 3.75D X 4.25”H)
2. Temperature Controller and Air Probe Installation
1) The temperature controller can be mounted either inside or outside the wine cellar, but the air probe must be located inside the wine cellar.
2) The air probe shall be located in the wine cellar 5 ft above the floor or the air return area, but it shall not be located in the air supply area or other areas where air is not circulated.
3) Air probe can be pulled out of the temperature controller around 5 ft; if additional wires are needed, 18 gauge wires may be used to extend the air probe.
3. Evaporator Unit Installation
1) The WM-25~85SFCD evaporator units shall be installed for ceiling mount with the supply air toward horizontal and return air on the bottom.
2) Air supply shall be unobstructed minimum 12” for a direct blow installation; leave 2” clearance for a deflector installation; air return shall be unobstructed minimum 6”.
3) The units may be recessed into the ceiling with short curved rectangular ducts;
CFM must be checked.
4) There is a gravity drain system used, so the unit shall be installed level or with a slight slope downward the drain connection and the drain line shall be installed slope down toward the drain. If rise-up is needed, a condensation pump must be used.
4. Condensing Unit Installation
CAUTION:
Low ambient condition kit is required if the installation area will be below
50
°
F. If the condensing unit is equipped with a low ambient condition kit, do not turn on the compressor until the condensing unit has been powered for minimum 12 hours.
1) Place the condensing units WM250~850SCU in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly.
2) Condensing unit shall be elevated to avoid possible flooding and shaded from direct sun. It shall not be exposed to temperatures higher than 110 °F or lower than 50 °F.
3) Leave minimum 5 ft clearance for the exhaust side and leave minimum 1 foot clearance for the ambient air intake side.
4) Service valve operations
1 - Process or Manometer
2 – Receiver Discharge or Compressor Suction
3 – Liquid Line or Suction Line
4 - Pressure Control
Back Position: Normal operation after installation is complete, process or manometer port is closed.
Front Position: Storage or shipping operation, liquid or suction line connection is closed.
Middle Position: Installation operation, all ports are open for evacuation, charge and manometer.
BACK POSITION FRONT POSITION MIDDLE POSITION
Fig. 10 ROTALOCK Valve Operation
BACK POSITION FRONT POSITION MIDDLE POSITION
Fig. 11 Base Valve Operation
5. Checking Pressure Control Settings
1) Use of the adjustable pressure control (if applicable for pump-down)
Suction pressure setting: Cut out=5 psig; Cut in=25 psig; Differential=20 psig
Head pressure setting: Cut out=230 psig; Cut in=150 psig; Differential=80 psig
It may need to adjust the setting in the field to get the right cycle time.
A. P70 Single/Dual Control
B. PS2 Dual Control
Fig. 12 Adjustable Pressure Control
2) Use of the encapsulated pressure control (if applicable)
Fixed suction pressure setting: Cut in = 32 psig; Cut out = 10 psig
Fig. 13 Fixed Pressure Control
3) Low ambient condition kit (if applicable)
A. Use of the condenser fan control
Head pressure setting: Cut in=170 psig; Cut out=110 psig; Differential=60 psig
It closes on rise of pressure. It may need to adjust the setting in the field to avoid fan short cycle.
Fig. 14 Condenser Fan Cycle Control
B. Use of the crankcase heater
The crankcase heater is installed around the lower part of the compressor and shall be turned on all the time. The heater is self-regulated.
6. Refrigeration Piping and Leak Testing
NOTES:
• The line connection sizes of liquid filter & indicator, the valve connection sizes of condensing unit and the line connection sizes of
evaporator unit are not necessary the same as the listed refrigeration line sizes.
• If the condensing unit is installed above the evaporator unit, use the suction line one listed size smaller.
• Expansion and solenoid valves have been installed on the liquid line in the evaporator unit.
1) The installation order starts from condensing unit (including receiver and discharge valve), liquid line filter-drier, moisture-liquid indicator, liquid line, to evaporator unit (including liquid line connection, solenoid valve, expansion valve, and suction line connection), returning to insulated suction line, suction valve and then back to condensing unit.
2) If the condensing unit is located below the evaporator unit, use inverted U trap to prevent liquid from flooding back to the compressor; if the elevation difference is more than 10 ft or the line set exceeds 75 ft, use both inverted U trap and suction accumulator.
3) If the condensing unit is located more than 10 ft above the evaporator unit, use U trap to aid oil returning to the compressor.
4) Complete pipe brazing, check solenoid valve and expansion valve restrictions and test leak.
5) Hook up the drain line and check if water drains.
The line sizes and refrigerant charges are listed as follows.
Model No
WM-2500SSD
WM-4500SSD
WM-6500SSD
WM-8500SSD
Equivalent
Line Set
<= 75 FT
<= 75 FT
<= 75 FT
<= 75 FT
Liquid
Line
1/4” OD
1/4” OD
1/4” OD
3/8” OD
Suction Line Drain Line
3/8” OD
1/2” OD
1/2” OD
5/8” OD
1/2” OD
1/2” OD
1/2” OD
1/2” OD
Recommended
Charge
R134a/19 OZ
R134a/26 OZ
R134a/32 OZ
R134a/40 OZ
7. Connecting Electrical Wires
Connect all electrical components using the wiring diagrams in accordance with all state and local codes.
8. Evacuating, Charging and Starting the system
CAUTION:
• Always use the superheat and subcooling, pressure readings to charge refrigerant properly; the listed charge amounts are used for reference only.
• If the unit is equipped with a low ambient condition kit and installed in the summer, charge 15% more refrigerant.
•
If the low ambient condition kit is used, turn off the compressor before power the condensing unit. Only turn on the compressor after the condensing unit has been powered for 12 hours.
1) Evacuate the system; both discharge and suction valves must be in the middle positions during evacuating.
2) Charge the system through both suction and discharge valves with refrigerant using the recommended initial amount; both discharge and suction valves must be in the middle positions during charging.
3) Turn on the power to start the system and check the following temperatures and pressures.
9. Adjusting and Completing the Installation
1) The subcooling at the condensing unit shall be around 10°F. The charge may be complete when there are no more bubbles forming in the liquid indicator.
2) Head pressure range: 120 ~ 170 psig at 70 ~ 90 °F condensing unit ambient temperature.
3) The evaporator’s constant pressure expansion valve is set around 30 ~ 35 psig (35 ~ 40°F) at factory. This pressure setting gives a dew point to maintain the proper humidity for storing wine.
4) The temperature split across the evaporator shall be 8 ~ 10°F at 55°F wine cellar temperature.
5) Again, you must verify if the superheat at the evaporator unit is around 9 ~
18°F at 55 °F ~ high wine cellar temperatures.
6) If the superheat is high, check the subcooling first to know if the refrigerant charge is sufficient. If the charge is not sufficient, add more refrigerant. If the charge is good, then increase the evaporator suction pressure by turning the hex nut (5/16”) clockwise. Liquid must always be charged into the hide side when the compressor runs.
7) If the superheat is low, then decrease the evaporator suction pressure by turning the hex nut (5/16”) counter-clockwise.
8) Both discharge and suction valves must be in the back positions before disconnecting.
9) Close all service valves and disconnect all manifolds and hoses.
Fig. 15 Expansion Valve
10. Pressure, Superheat and Subcooling Readings
CAUTION:
To read properly the service valves must be in the middle positions.
1) High suction pressure and low head pressure
Zero superheat and zero subcooling
2) High suction pressure and low head pressure
Low superheat and low subcooling
3) High suction pressure and high head pressure
Low superheat and high subcooling
4) High to normal suction pressure and high head pressure
Low subcooling
5) High suction pressure and high head pressure
Low superheat and low subcooling
6) High suction pressure and high head pressure
High superheat
7) Low suction pressure and low head pressure
1) Compressor may be bad
2) Expansion valve opened, too much oil
3) Overcharge
5) Air restricted, dirty condenser, bad condenser fans
6) High cellar temperature, high evaporator load
7) Undercharge
High superheat and low subcooling
8) Low suction pressure and low to normal head pressure
High superheat and high subcooling
9) Low suction pressure and low head pressure
Normal to high superheat and low subcooling
10) Low suction pressure and low head pressure
Low superheat and low subcooling
11) Low suction pressure and low to normal head pressure
High superheat and normal to high subcooling
12) Low suction pressure and normal head pressure receiver, solenoid valve restricted
9) Suction line restricted
10) Air restricted at evaporator, evaporator iced
11) Evaporator restricted
12) Expansion valve restricted
High superheat and normal subcooling
13) Low suction pressure and high head pressure
High superheat and high subcooling
13) Both evaporator and condenser restricted; liquid and suction lines connected wrong
14) Low suction pressure and high head pressure
High superheat and high subcooling
15) low to normal suction pressure and high head pressure
Normal to high superheat and high subcooling receiver
15) Condenser restricted
11. Condensing Unit Troubleshooting
1) Incorrect power supply
2) Incorrect or loose wirings
Unit not running
1) Check for proper voltage
4) Low pressure switch shutting down the system
5) high pressure switch shutting down the system
2) Check all wirings and connections
3) Check start relay, start capacitor, overload protector, compressor.
4) Check for system restriction or low refrigerant
5) Check for the condenser fan
Electrical Wiring Diagrams
CAUTION:
• Hidden lines are the field wirings.
• Use minimum 14 gauge wires for power lines.
• If equipped with low ambient condition kit, use low ambient temperature wiring diagrams.
• A safety switch is always recommended for the condensing unit.
Fig. 16 WM-2500~4500SSD Wiring Diagram
Fig. 17 WM-6500SSD Electrical Wiring Diagram
Fig. 18 WM-8500SSD Electrical Wiring Diagram
Fig. 19 Low Ambient Temperature
WM-2500~4500SSD-LA Electrical Wiring Diagram
Fig. 20 Low Ambient Temperature
WM-6500SSD-LA Electrical Wiring Diagram
Fig. 21 Low Ambient Temperature
WM-8500SSD-LA Electrical Wiring Diagram
Customer Support
If you need further assistance, please contact us at:
Vinotemp International
17631 South Susana Road
Rancho Dominguez, CA 90221
Tel: (310) 886-3332
Fax: (310) 886-3310
Email: [email protected]
Warranty
Thank you for choosing a Vinotemp cooling unit.
Please enter the complete model and serial numbers in the space provided:
Model_________________________________________________________
Serial No.______________________________________________________
Attach your purchase receipt to this owner’s manual.
1. Limited Warranty
VINOTEMP warrants its products, parts only, to be free from defects due to workmanship or materials under normal use and service for twelve months after the initial sale. If the product is defective due to workmanship or materials, is removed within twelve months of the initial sale and is returned to VINOTEMP, in the original shipping carton, shipping prepaid, VINOTEMP will at its option, repair or replace the product free of charge.
This warranty constitutes the entire warranty of the VINOTEMP with respect to its products and is in lieu of all other warranties, express or implied, including any of fitness for a particular purpose. In no event shall VINOTEMP be responsible for any consequential damages what is so ever. Any modification of VINOTEMP products shall void this warranty.
Service under Warranty
This service is provided to customers within the continental UNITED STATES only. VINOTEMP cooling units are warranted to produce the stated number of
BTU/H. While every effort has been made to provide accurate guidelines,
VINOTEMP can not warranty its units to cool a particular enclosure.
In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
Shall a VINOTEMP cooling unit fail, contact the dealer for instructions, do not return the unit to the factory without authorization from VINOTEMP. If the unit requires repair, re-pack it in the original shipping carton and return it to the factory, shipping prepaid. VINOTEMP will not accept COD shipments. If the unit is determined to be faulty and is within the twelve month warranty period
VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.
2. Limitation of Implied Warranty
VINOTEMP’S SOLE LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED
TO, AT OUR OPTION, REPAIRING OR REPLACING OF UNIT.
VINOTEMP SHALL NOT BE LIABLE FOR:
DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE UNIT,
DAMAGES BASED UPON INCONVENIENCE, LOSS OF USE OF THE UNIT,
LOSS OF TIME OR COMMERCIAL LOSS, ANY OUTER DAMAGES,
WHETHER INCIDENTAL, CONSEQUENTIAL OR OTHERWISE.
THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR INPLIED, INCLUDING BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to properly cool a particular enclosure. Customers are cautioned that enclosure construction, unit location and many other factors can affect the operation and performance of the unit. There for suitability of the unit for a specific enclosure or application must be determined by the customer and cannot be warranted by VINOTEMP.