Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | [email protected] | www.ashly.com | Ashly is a division of Jam Industries, Ltd.

5-Year Warranty Ashly EMS™ 70V Rated 100V Rated

NXE SERIES

P ower

A mPlifiers w

/ P rogrAmmAble o utPuts

A nd

e thernet

C ontrol

Ashly’s new line of nX Power Amplifiers feature lightweight, energy-efficient

Class-D switching amplifier technology combined with a switch mode power supply. nX amplifiers are available in three product families (nX, nXe, nXp) and are designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces and convention centers.

The nXe Series is available in either 2 or

4-channel models. Use rear panel DIP switches to program each channel output for either High-Z (70V or 100V Constant

Voltage) or Low-Z (stable down to 2 Ohms) operation. When in Sleep Mode, the nX amplifiers draw less than 1 Watt.

nXe is networkable with Ethernet control.

It also has serial data control, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, and optional network audio and digital audio capability. All controlled using our Protea™

Software Suite.

nXe Series Features:

• 2 and 4-channel high-output, lightweight amplifiers with programmable output on each channel (High-Z or Low-Z, selected via rear panel DIP switches)

• Power-saving, Energy Management

System ‡ (Ashly EMS™) automatic

<1W sleep-mode (defeatable)

• Front panel power switch and level controls

(can be disabled for security)

• Rear panel DIP switches per channel for selection of high pass filter, limiter, input gain, and High-Z or Low-Z speaker output configuration

• Remote DC level control on each input channel

• Switch mode power supply automatically detects 120V or 240V AC operation

• Extensive protection circuitry, continuously variable cooling fans

• Multiple independent internal power supplies provide increased channel separation and reliability

• Ethernet port for use with control and monitoring of amplifier functions, with front panel COM activity LED

• Serial data port for use with Ashly remote control devices, or optional RS-232 converter for third party controllers (INA-1)

• Use Protea™ Software to remotely disable all front panel controls, including the on/off switch, for a tamper-proof installation

• Real-Time Clock with Event Scheduler

• Instant Standby Mode, 30% reduction in power consumption with on/off triggered by contact closure, software control, or event scheduler

• Programmable power-on delay

• Preset recall via contact closure, software control, remote control, or event scheduler

• Aux preamp outputs, and fault condition logic outputs

• Optional Cobranet® or Dante® network audio and AES3 digital audio input with pass-through

• Neutrik® Combo XLR – 1/4” TRS jack plus

Euroblock input connectors

• Neutrik® speakON® twist locking loudspeaker connectors for security, safety, and reliability

• Neutrik® powerCON® detachable AC mains connector

nXe Series

nXe

3.04

3000 & 1500 Watt Models nXe

3.02

nXe

1.54

nXe

1.52

nXe

8004

800 & 400 Watt Models nXe

8002 nXe

4004 nXe

4002

Channels 4 2 4 2 4 2

*Max Output Power: Measured in Watts, Per Channel, Low-Z Output, All Channels Driven

4

2 Ohms

4 Ohms

3,000 3,000 1,500 1,500

2,000 2,000 1,500 1,500

800

800

8 Ohms 1,250 1,250 1,250 1,250 800

*Low Z Output: Measured in Watts, Bridge Mode, All Channels Driven

800

800

800

400

400

400

4 Ohms

8 Ohms

6,000 6,000 3,000 3,000

4,000 4,000 3,000 3,000

*70V, 100V Output: Measured in Watts, All Channels Driven

1600

1600

1600

1600

800

800

70V (per channel)

100V (per channel)

2,450 2,450 1,500 1,500

1,250 1,250 1,250 1,250

Total Power Draw, Measured in Watts, Total for all Channels

800

800

800

800

400

400

2

800

800

400

400

Sleep Mode

Standby Mode

< 1

70

< 1

40

< 1

70

< 1

40

< 1

40

< 1

25

Idle (no signal) 100 55 100 55 70 40

Current Draw: Measured in Amps, Total for all Channels, 120VAC, Divide by 2 for 240V

< 1

40

70

Sleep Mode

Standby Mode

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

1.30

0.70

1.30

0.70

0.70

0.38

0.70

0.38

Idle (no signal) 1.85

1.00

1.85

1.00

1.30

0.70

1.30

0.70

Max Current Draw: Measured in Amps, Typical Input, All Channels Driven, Divide by 2 for 240V

< 1

25

40

⅛ Max Power @ 2 Ohms 29.5

14.7

16.0

8.0

Thermal Dissipation: BTU/hr, Typical Input, Total for all Channels

Sleep mode

Standby mode

< 3.4

238

< 3.4

136

< 3.4

238

< 3.4

136

8.8

< 3.4

136

4.6

< 3.4

85

5.0

< 3.4

136

2.6

< 3.4

85

Idle (no signal) 340 187 340 187

⅛ Max Power @ 2 Ohms 2,720 1,360 1,700 850

238

970

136

495

238

595

136

305

400

400

400

* Measurements based on CEA-2006/490A, 20mS 1kHz 1% THD+N, 480mS 1kHz -20dB.

‡ <1W sleep mode can be defeated for applications that are subject to third-party performance standards that prohibit a sleep mode, including those used for Mass Notification and Emergency Communication Systems and those subject to ANSI/UL 2572.

Note: When making a true comparison of energy efficiency, one must look at the Thermal Dissipation (BTU/hr) numbers for a product. All other efficiency, i.e. "percentage" numbers are not standards based, and therefore may be marketing hype. Ashly

Audio builds highly efficient Class-D amplification with SMPS that will equal or surpass the competition on BTU/hr thermal output

(unused energy given off as heat). Please check our published BTU/hr specifications for more information.

Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | [email protected] | www.ashly.com | Ashly is a division of Jam Industries, Ltd. nXe 3.04 Rear Panel Configuration

NXE SERIES

Specifications Notes: 0dBu = 0.775 VRMS

Voltage Gain

Damping Factor

Selectable at 26dB, 32dB, 38dB, or 1.4V

>250 (8 Ohms load <1kHz)

Input High Pass Filter

Distortion (SMPTE, typical)

Distortion (THD-N, typical)

80Hz 2nd order

<0.5%

<0.5% (8 Ohms, 10dB below rated power, 20Hz–20kHz)

Channel Separation -75dB (dB from full output, 1kHz)

Signal-to-Noise

(20Hz–20kHz, unweighted)

Frequency Response

>114dB (all 3.0x models)

>111dB (all 1.5x models)

>108dB (all 800x models)

>105dB (all 400x models)

20Hz–20kHz, +/-0.05dB

Balanced Input Connector

Input Impedance

Maximum Input Level

Speaker Output Connector

Control Network

AUX Output Connector

AUX Output Maximum Level

Remote Standby Contact

Closure

Euroblock 3.5mm, 1/4” TRS and

XLR Combo jack

10k Ohms

+21dBu

Neutrik® speakON®

Compatible w/ standard 100MB Ethernet

Balanced Euroblock 3.5mm

+21dBu

Euroblock 3.5mm, close contact to

GND for standby mode

Preset Recall Contact Closure

Data Connection

Fault Condition Logic Outputs Euroblock 3.5mm - 4 available

Remote DC Level Control

Euroblock 3.5mm - Gnd, CV, V+ per input

Attenuators (per channel)

Euroblock 3.5mm, close contact to

GND for preset 1-4 recall

Euroblock 3.5mm - Gnd, +18V, In, Out

Amplifier Protection

Cooling

Environmental

Front panel, software, offset link group, and remote. Fully off = Mute

Inrush current limitation, temperature monitoring, output over-power protection, mains fuses

Continuously variable temperature controlled axial fan(s)

32–113 deg F, (0–45 deg, C)

(noncondensing)

Unit Dimensions

(all models)

Shipping

Dimensions

P ower

A mPlifiers w

/ P rogrAmmAble o utPuts

A nd

e thernet

C ontrol

Front Panel LED Indicators

White LED

POWER

Red LED

CLIP/MUTE

PROTECT

Green LED

SIGNAL

Switch: On, Off, Standby (flashing)

Per Channel: Clip @ 1dB below full output / Mute

On (fault condition or shut down), Off

BRIDGE

COM

CURRENT

Yellow LED

Per Channel: -18dB below rated output

Per Channel Pair: On, Off

On, for Ethernet data or Device ID

Per Channel: Proportional to output

TEMP

SLEEP

DISABLE

Per Channel: On dim at 90% max operating temperature, full bright + protect at 100%

On, amplifier is asleep from audio inactivity

On, power switch & front panel attenuators are disabled

Weights and Dimensions

Unit Weight

1.54/3.04: 28.7lbs (13kg) 1.52/3.02: 22.7lbs (10.3kg)

4002/8002: 22.2lbs (10.1kg) 4004/8004: 25.9lbs (11.7kg)

19”W x 3.5”H x 16.84”D (483mm x 89mm x 428mm)

24.5"W x 22"H x 5.25"D (622mm x 559mm x 133mm)

Power Requirements (@ 50/60Hz)

Nominal (Automatic Sensing SMPS)

Operating Range

Minimum power-up

Power Cable Connector

120VAC

70–135VAC

240VAC

140–270VAC

85VAC 170VAC

20A powerCON®

(32A powerCON® 3.04 model only)

Digital Input Options (Factory installed w/ DAC4 Converter)

OPAES2 2-Ch AES3 Input w/ AES3 pass-thru

OPAES4

CNM-2

4-Ch AES3 Input w/ AES3 pass-thru

CobraNet® Digital Interface

OPDante

OPAVB

Dante® Digital Interface

AVB Digital Interface (in development)

Remote Accessories

WR-1

WR-1.5

WR-2

WR-5* neWR-5*

FR-8

FR-16

Ashly Remote

2-Channel Level Control

Level and Preset Recall

Four-Position Switch

Programmable Button Controller

Programmable Network Button Controller

8-Channel Network Fader Remote

16-Channel Network Fader Remote

Remote Control Application for Apple® iPad®

*Function is limited to Mute and Preset Recall ©2014 All features, specifications and graphical representations are subject to change or improvement without notice and may not represent the final product.

DS-1114

Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | [email protected] | www.ashly.com | Ashly is a division of Jam Industries, Ltd.

NXE SERIES

A rChiteCt

& e ngineering

s

PeCs nXe3.04

The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 3,000W per channel at Low Z, 2,450W per channel in 70V mode, and

1,250W in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect

120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and

Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <28.7 lbs (13kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.

The power amplifier shall be an Ashly nXe3.04. nXe3.02

The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 3,000W per channel at Low Z, 2,450W per channel in 70V mode, and

1,250W in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect

120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and

Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.7 lbs (10.3kg), measure 19”W x

3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.

The power amplifier shall be an Ashly nXe3.02. nXe1.54

The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 1,500W per channel at Low Z and 70V modes, and 1,250W in 100V mode.

There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or

1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <28.7 lbs (13kg), measure 19”W x 3.5”H x 16.8”D (483mm x

89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.

The power amplifier shall be an Ashly nXe1.54. nXe1.52

The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 1,500W per channel at Low Z and 70V modes, and 1,250W in 100V mode.

There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or

1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.7 lbs (10.3kg), measure 19”W x 3.5”H x 16.8”D (483mm x

89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.

The power amplifier shall be an Ashly nXe1.52.

Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | [email protected] | www.ashly.com | Ashly is a division of Jam Industries, Ltd.

NXE SERIES

A rChiteCt

& e ngineering

s

PeCs nXe8004

The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 800W per channel at Low Z, 70V, and 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and

AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <25.9 lbs (11.7kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.

The power amplifier shall be an Ashly nXe8004. nXe8002

The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 800W per channel at Low Z, 70V, and 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and

AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.2 lbs (10.1kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.

The power amplifier shall be an Ashly nXe8002. nXe4004

The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 400W per channel at Low Z, 70V, and 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and

AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <25.9 lbs (11.7kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.

The power amplifier shall be an Ashly nXe4004. nXe4002

The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 400W per channel at Low Z, 70V, and 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and

AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.2 lbs (10.1kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.

The power amplifier shall be an Ashly nXe4002.