advertisement
Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | [email protected] | www.ashly.com | Ashly is a division of Jam Industries, Ltd.
5-Year Warranty Ashly EMS™ 70V Rated 100V Rated
NXE SERIES
P ower
A mPlifiers w
/ P rogrAmmAble o utPuts
A nd
e thernet
C ontrol
Ashly’s new line of nX Power Amplifiers feature lightweight, energy-efficient
Class-D switching amplifier technology combined with a switch mode power supply. nX amplifiers are available in three product families (nX, nXe, nXp) and are designed to meet the most demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces and convention centers.
The nXe Series is available in either 2 or
4-channel models. Use rear panel DIP switches to program each channel output for either High-Z (70V or 100V Constant
Voltage) or Low-Z (stable down to 2 Ohms) operation. When in Sleep Mode, the nX amplifiers draw less than 1 Watt.
nXe is networkable with Ethernet control.
It also has serial data control, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, and optional network audio and digital audio capability. All controlled using our Protea™
Software Suite.
nXe Series Features:
• 2 and 4-channel high-output, lightweight amplifiers with programmable output on each channel (High-Z or Low-Z, selected via rear panel DIP switches)
• Power-saving, Energy Management
System ‡ (Ashly EMS™) automatic
<1W sleep-mode (defeatable)
• Front panel power switch and level controls
(can be disabled for security)
• Rear panel DIP switches per channel for selection of high pass filter, limiter, input gain, and High-Z or Low-Z speaker output configuration
• Remote DC level control on each input channel
• Switch mode power supply automatically detects 120V or 240V AC operation
• Extensive protection circuitry, continuously variable cooling fans
• Multiple independent internal power supplies provide increased channel separation and reliability
• Ethernet port for use with control and monitoring of amplifier functions, with front panel COM activity LED
• Serial data port for use with Ashly remote control devices, or optional RS-232 converter for third party controllers (INA-1)
• Use Protea™ Software to remotely disable all front panel controls, including the on/off switch, for a tamper-proof installation
• Real-Time Clock with Event Scheduler
• Instant Standby Mode, 30% reduction in power consumption with on/off triggered by contact closure, software control, or event scheduler
• Programmable power-on delay
• Preset recall via contact closure, software control, remote control, or event scheduler
• Aux preamp outputs, and fault condition logic outputs
• Optional Cobranet® or Dante® network audio and AES3 digital audio input with pass-through
• Neutrik® Combo XLR – 1/4” TRS jack plus
Euroblock input connectors
• Neutrik® speakON® twist locking loudspeaker connectors for security, safety, and reliability
• Neutrik® powerCON® detachable AC mains connector
nXe Series
nXe
3.04
3000 & 1500 Watt Models nXe
3.02
nXe
1.54
nXe
1.52
nXe
8004
800 & 400 Watt Models nXe
8002 nXe
4004 nXe
4002
Channels 4 2 4 2 4 2
*Max Output Power: Measured in Watts, Per Channel, Low-Z Output, All Channels Driven
4
2 Ohms
4 Ohms
3,000 3,000 1,500 1,500
2,000 2,000 1,500 1,500
800
800
8 Ohms 1,250 1,250 1,250 1,250 800
*Low Z Output: Measured in Watts, Bridge Mode, All Channels Driven
800
800
800
400
400
400
4 Ohms
8 Ohms
6,000 6,000 3,000 3,000
4,000 4,000 3,000 3,000
*70V, 100V Output: Measured in Watts, All Channels Driven
1600
1600
1600
1600
800
800
70V (per channel)
100V (per channel)
2,450 2,450 1,500 1,500
1,250 1,250 1,250 1,250
Total Power Draw, Measured in Watts, Total for all Channels
800
800
800
800
400
400
2
800
800
400
400
Sleep Mode
Standby Mode
< 1
70
< 1
40
< 1
70
< 1
40
< 1
40
< 1
25
Idle (no signal) 100 55 100 55 70 40
Current Draw: Measured in Amps, Total for all Channels, 120VAC, Divide by 2 for 240V
< 1
40
70
Sleep Mode
Standby Mode
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
1.30
0.70
1.30
0.70
0.70
0.38
0.70
0.38
Idle (no signal) 1.85
1.00
1.85
1.00
1.30
0.70
1.30
0.70
Max Current Draw: Measured in Amps, Typical Input, All Channels Driven, Divide by 2 for 240V
< 1
25
40
⅛ Max Power @ 2 Ohms 29.5
14.7
16.0
8.0
Thermal Dissipation: BTU/hr, Typical Input, Total for all Channels
Sleep mode
Standby mode
< 3.4
238
< 3.4
136
< 3.4
238
< 3.4
136
8.8
< 3.4
136
4.6
< 3.4
85
5.0
< 3.4
136
2.6
< 3.4
85
Idle (no signal) 340 187 340 187
⅛ Max Power @ 2 Ohms 2,720 1,360 1,700 850
238
970
136
495
238
595
136
305
400
400
400
* Measurements based on CEA-2006/490A, 20mS 1kHz 1% THD+N, 480mS 1kHz -20dB.
‡ <1W sleep mode can be defeated for applications that are subject to third-party performance standards that prohibit a sleep mode, including those used for Mass Notification and Emergency Communication Systems and those subject to ANSI/UL 2572.
Note: When making a true comparison of energy efficiency, one must look at the Thermal Dissipation (BTU/hr) numbers for a product. All other efficiency, i.e. "percentage" numbers are not standards based, and therefore may be marketing hype. Ashly
Audio builds highly efficient Class-D amplification with SMPS that will equal or surpass the competition on BTU/hr thermal output
(unused energy given off as heat). Please check our published BTU/hr specifications for more information.
Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | [email protected] | www.ashly.com | Ashly is a division of Jam Industries, Ltd. nXe 3.04 Rear Panel Configuration
NXE SERIES
Specifications Notes: 0dBu = 0.775 VRMS
Voltage Gain
Damping Factor
Selectable at 26dB, 32dB, 38dB, or 1.4V
>250 (8 Ohms load <1kHz)
Input High Pass Filter
Distortion (SMPTE, typical)
Distortion (THD-N, typical)
80Hz 2nd order
<0.5%
<0.5% (8 Ohms, 10dB below rated power, 20Hz–20kHz)
Channel Separation -75dB (dB from full output, 1kHz)
Signal-to-Noise
(20Hz–20kHz, unweighted)
Frequency Response
>114dB (all 3.0x models)
>111dB (all 1.5x models)
>108dB (all 800x models)
>105dB (all 400x models)
20Hz–20kHz, +/-0.05dB
Balanced Input Connector
Input Impedance
Maximum Input Level
Speaker Output Connector
Control Network
AUX Output Connector
AUX Output Maximum Level
Remote Standby Contact
Closure
Euroblock 3.5mm, 1/4” TRS and
XLR Combo jack
10k Ohms
+21dBu
Neutrik® speakON®
Compatible w/ standard 100MB Ethernet
Balanced Euroblock 3.5mm
+21dBu
Euroblock 3.5mm, close contact to
GND for standby mode
Preset Recall Contact Closure
Data Connection
Fault Condition Logic Outputs Euroblock 3.5mm - 4 available
Remote DC Level Control
Euroblock 3.5mm - Gnd, CV, V+ per input
Attenuators (per channel)
Euroblock 3.5mm, close contact to
GND for preset 1-4 recall
Euroblock 3.5mm - Gnd, +18V, In, Out
Amplifier Protection
Cooling
Environmental
Front panel, software, offset link group, and remote. Fully off = Mute
Inrush current limitation, temperature monitoring, output over-power protection, mains fuses
Continuously variable temperature controlled axial fan(s)
32–113 deg F, (0–45 deg, C)
(noncondensing)
Unit Dimensions
(all models)
Shipping
Dimensions
P ower
A mPlifiers w
/ P rogrAmmAble o utPuts
A nd
e thernet
C ontrol
Front Panel LED Indicators
White LED
POWER
Red LED
CLIP/MUTE
PROTECT
Green LED
SIGNAL
Switch: On, Off, Standby (flashing)
Per Channel: Clip @ 1dB below full output / Mute
On (fault condition or shut down), Off
BRIDGE
COM
CURRENT
Yellow LED
Per Channel: -18dB below rated output
Per Channel Pair: On, Off
On, for Ethernet data or Device ID
Per Channel: Proportional to output
TEMP
SLEEP
DISABLE
Per Channel: On dim at 90% max operating temperature, full bright + protect at 100%
On, amplifier is asleep from audio inactivity
On, power switch & front panel attenuators are disabled
Weights and Dimensions
Unit Weight
1.54/3.04: 28.7lbs (13kg) 1.52/3.02: 22.7lbs (10.3kg)
4002/8002: 22.2lbs (10.1kg) 4004/8004: 25.9lbs (11.7kg)
19”W x 3.5”H x 16.84”D (483mm x 89mm x 428mm)
24.5"W x 22"H x 5.25"D (622mm x 559mm x 133mm)
Power Requirements (@ 50/60Hz)
Nominal (Automatic Sensing SMPS)
Operating Range
Minimum power-up
Power Cable Connector
120VAC
70–135VAC
240VAC
140–270VAC
85VAC 170VAC
20A powerCON®
(32A powerCON® 3.04 model only)
Digital Input Options (Factory installed w/ DAC4 Converter)
OPAES2 2-Ch AES3 Input w/ AES3 pass-thru
OPAES4
CNM-2
4-Ch AES3 Input w/ AES3 pass-thru
CobraNet® Digital Interface
OPDante
OPAVB
Dante® Digital Interface
AVB Digital Interface (in development)
Remote Accessories
WR-1
WR-1.5
WR-2
WR-5* neWR-5*
FR-8
FR-16
Ashly Remote
2-Channel Level Control
Level and Preset Recall
Four-Position Switch
Programmable Button Controller
Programmable Network Button Controller
8-Channel Network Fader Remote
16-Channel Network Fader Remote
Remote Control Application for Apple® iPad®
*Function is limited to Mute and Preset Recall ©2014 All features, specifications and graphical representations are subject to change or improvement without notice and may not represent the final product.
DS-1114
Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | [email protected] | www.ashly.com | Ashly is a division of Jam Industries, Ltd.
NXE SERIES
A rChiteCt
& e ngineering
s
PeCs nXe3.04
The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 3,000W per channel at Low Z, 2,450W per channel in 70V mode, and
1,250W in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect
120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and
Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <28.7 lbs (13kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.
The power amplifier shall be an Ashly nXe3.04. nXe3.02
The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 3,000W per channel at Low Z, 2,450W per channel in 70V mode, and
1,250W in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect
120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and
Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.7 lbs (10.3kg), measure 19”W x
3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.
The power amplifier shall be an Ashly nXe3.02. nXe1.54
The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 1,500W per channel at Low Z and 70V modes, and 1,250W in 100V mode.
There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or
1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <28.7 lbs (13kg), measure 19”W x 3.5”H x 16.8”D (483mm x
89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.
The power amplifier shall be an Ashly nXe1.54. nXe1.52
The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 1,500W per channel at Low Z and 70V modes, and 1,250W in 100V mode.
There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or
1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.7 lbs (10.3kg), measure 19”W x 3.5”H x 16.8”D (483mm x
89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.
The power amplifier shall be an Ashly nXe1.52.
Ashly Audio, Inc. | 847 Holt Road | Webster, NY 14580-9103 USA | US toll free: +1-800-828-6308 | tel: +1-585-872-0010 | fax: +1-585-872-0739 | [email protected] | www.ashly.com | Ashly is a division of Jam Industries, Ltd.
NXE SERIES
A rChiteCt
& e ngineering
s
PeCs nXe8004
The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 800W per channel at Low Z, 70V, and 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and
AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <25.9 lbs (11.7kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.
The power amplifier shall be an Ashly nXe8004. nXe8002
The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 800W per channel at Low Z, 70V, and 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and
AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.2 lbs (10.1kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.
The power amplifier shall be an Ashly nXe8002. nXe4004
The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 400W per channel at Low Z, 70V, and 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and
AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <25.9 lbs (11.7kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.
The power amplifier shall be an Ashly nXe4004. nXe4002
The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 400W per channel at Low Z, 70V, and 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 120VAC or 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and
AES3 digital audio capability. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.2 lbs (10.1kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. There shall be a five year warranty for units purchased in the US. No other unit shall be acceptable unless all specifications represented herein are met or exceeded and submitted in writing by an independent testing agent.
The power amplifier shall be an Ashly nXe4002.