Soleus Air PAC12 User manual

Add to my manuals
17 Pages

advertisement

Soleus Air PAC12 User manual | Manualzz

USER MANUAL

Portable Air Conditioner and Heater

With Heat Pump Technology

PAC12 PAC15

PAC18

Please read this manual carefully prior to operating the product.

TABLE OF CONTENTS

INTRODUCTION..................................................................................................................................................................................... 3

IMPORTANT SAFEGUARDS.................................................................................................................................................................. 4

PRODUCT DIAGRAM.......................................................................................................................................................................... 5-6

INSTALLATION ....................................................................................................................................................................................... 7

WINDOW KIT INSTALLATION................................................................................................................................................................ 8

CONTROL PANEL AND MULTI-COLOR DISPLAY

PAC12

............................................................................................................. 9

CONTROL PANEL AND MULTI-COLOR DISPLAY

PAC15

........................................................................................................... 10

CONTROL PANEL AND MULTI-COLOR DISPLAY

PAC18

............................................................................................................11

CONTROL PANEL FUNCTIONS .......................................................................................................................................................... 12

COOLING MODE .................................................................................................................................................................................. 13

DEHUMIDIFYING MODE...................................................................................................................................................................... 13

FAN MODE............................................................................................................................................................................................ 13

HEATING MODE................................................................................................................................................................................... 13

AUTO MODE......................................................................................................................................................................................... 13

SLEEP MODE ....................................................................................................................................................................................... 14

REMOTE CONTROL & OPERATION ................................................................................................................................................... 14

WATER DRAINAGE.............................................................................................................................................................................. 15

MAINTENANCE .................................................................................................................................................................................... 16

TROUBLESHOOTING .......................................................................................................................................................................... 17

TECHNICAL SUPPORT / CUSTOMER SERVICE CONTACT ............................................................................................................. 17

2

INTRODUCTION

Thank you for purchasing the PAC12, PAC15 or PAC18 Portable Air Conditioner and Heater. This unit is designed to improve indoor living and working comfort by providing cooling, dehumidifying, heating, and ventilation with minimal installation.

Please complete the following information for future reference. Retain this owner’s manual with your sales receipt as a permanent record of your purchase.

Serial Number: _________________________________________________________

Date of Purchase: _______________________________________________________

Place of Purchase: _______________________________________________________

3

IMPORTANT SAFEGUARDS

Before installing and using your portable air conditioner and heater, it is important that you read this owner’s manual carefully. Store this manual in a safe place for future reference.

This instruction manual is used for guidance and does not form part of a contract. It reserves the right to make technical changes without prior notice.

1.

Always place the unit on a level surface.

2.

The appliance shall be installed in accordance with national wiring regulation.

3.

The unit must be connected to a correctly grounded power supply. For your safety, this unit is grounded through the power cord plug when connected to a grounded wall outlet. Do not use an adapter plug or extension cord.

4.

Do not install the unit in an area where gas leakage may occur and/or in an explosive atmosphere.

5.

Do not apply an insecticide or any type of flammable spray on the unit.

6.

Confirm drainage piping is connected properly.

7.

Do not start or stop the unit by inserting or pulling out the power plug.

8.

Do not operate with wet hands.

9.

Close supervision is necessary when the unit is used near children. The unit in not intended for use by children.

10.

Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills.

11.

Do not expose skin or eyes directly to cool air for a long period of time.

12.

If an abnormal odour or smoke comes out of the unit, disconnect the unit immediately and contact a qualified service technician.

13.

When opening the filter cover, do not touch the metal parts in the unit’s interior.

14.

Do not immerse the unit in water or any type of liquid. Do not use the unit in the immediate surroundings of a bath, shower, or swimming pool, or in any other steamy, wet areas.

15.

When cleaning the unit, always turn the unit off and unplug the power cord.

16.

Always inspect the power cord for signs of damage before use. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service technician.

17.

Do not place a plant or allow a pet in the direct path of the airflow to avoid injury.

18.

Do not put a stove, etc, where it would be exposed to the direct airflow. It may affect combustion.

19.

Do not sit on the unit or place anything on it.

20.

Before storing, the water must be drained from the unit and the filters cleaned.

4

PRODUCT DIAGRAM

FRONT

PAC12

A.

Control panel

B.

Vertical air louvers

C.

Air outlet

D.

Castors

E.

Cable (power cord and plug)

FRONT

PAC15

A

Control panel

B

Vertical air louvers

C

Air outlet

D

Horizontal air louvers

E

Castors

F

Cable (power cord and plug)

FRONT

PAC18

A

Control panel

B

Vertical air louvers

C

Air outlet

D

Castors

F

Cable (power cord and plug)

F

D

A

B

C

5

BACK

A.

Hot air outlet grill

B.

Lower air inlet grill

ACCESSORIES

Flexible exhaust hose with 2 adapters

• 3-piece set

• stretches from 14 1/4” to 60 5/8”

(36cm to 150cm)

Window exhaust adapter

Adjustable window slider kit

• 3-piece set

• adjusts 33 1/2” to62” (85cm to 157.5cm)

Drain tube

Drain pan

6

INSTALLATION

SELECTING THE LOCATION

Place the unit in a flat location where the air outlets are not obstructed. Place the unit at least 20” (50cm) away from a wall or other obstacle.

MOUNTING THE EXHAUST HOSE

Slide the square end of the exhaust duct over the hot air outlet on the back of the unit.

The exhaust hose should be kept as short and straight as possible. Prevent any sharp bends in the exhaust hose, as this will trap hot exhaust air.

The hot exhaust air can be vented through the wall or out a window. If mounting in the wall, the height of the hole should be 16 to 50 inches

(40cm to 130cm).

7

WINDOW KIT INSTALLATION

The window kit is designed to fit into most standard vertical and horizontal windows.

However, it may be necessary to modify some aspects of the installation process for certain window types.

1.

Open the window or sliding door and adjust the length of the window kit to fit the opening. Mark and cut down a single panel of the window kit if necessary.

2.

Place the window kit between the window and the window frame as shown in the images to the right. Close the window onto the window kit to form a tight seal.

3.

Attach the exhaust duct adapter to the window kit. Tabs located on the adapter will lock into place securing the adapter to the window kit.

8

CONTROL PANEL AND MULTI-COLOR DISPLAY

PAC12

CONTROL PANEL

FAN SPEED

SWING

AM

PM

MODE ON/OFF

TIMER ON

TIMER OFF

FAN SPEED

Button

Press this button to choose high, medium or low fan speed. In dehumidifying mode, this button is inoperable.

SWING Button Press this button to oscillate the vertical louvers or to stop oscillation.

Button

This button decreases the room temperature/timer hours.

Button

This button increases the room temperature/timer hours.

Power Button Press this button to turn the unit on or off.

MODE Button Press this button to select the mode (auto, cooling, dehumidifying, fan or heating).

TIMER Button Press this button to turn the timer on/off.

A.

Auto Mode

B.

Cool Mode

C.

Dehumidify Mode

D.

Fan Mode

E.

Heat Mode

F.

Fan Speed (Low, High, Medium)

G.

Temperature

H.

Swing Mode

I.

Sleep Mode

J.

Clock and Timer

K.

Timer On

L.

Timer Off

M.

Compressor is on

G

B C D

9

H

AM

PM

I

E F

J

K

L

M

CONTROL PANEL AND MULTI-COLOR DISPLAY

PAC15

CONTROL PANEL

FAN SPEED

Button

Press this button to choose high, medium or low fan speed. In dehumidifying mode, this button is inoperable.

SWING Button Press this button to oscillate the vertical louvers or to stop oscillation.

Button

This button decreases the room temperature/timer hours.

Button

This button increases the room temperature/timer hours.

Power Button Press this button to turn the unit on or off.

MODE Button Press this button to select the mode (auto, cooling, dehumidifying, fan or heating).

TIMER Button Press this button to turn the timer on/off.

MULTI-COLOR DISPLAY

A.

Auto Mode

B.

Cool Mode

C.

Dehumidify Mode

D.

Fan Mode

E.

Heat Mode

F.

Fan Speed (Low, High, Medium)

G.

Temperature

H.

Swing Mode

I.

Sleep Mode

J.

Clock and Timer

K.

Timer On

L.

Timer Off

M.

Compressor is on

10

CONTROL PANEL AND MULTI-COLOR DISPLAY

( ( ( (

PAC18

) ) ) )

CONTROL PANEL

C

F

Power Button

Mode Button

Swing Button

MOD

E

FAN

SWING

POW

ER

Press this button to turn the unit on or off.

Press this button to select the mode (auto, cooling, dehumidifying, fan or heating).

Press this button to oscillate the vertical louvers or to stop oscillation.

Fan Speed Button Press this button to choose high, medium or low fan speed. In dehumidifying mode, this button is inoperable.

Dial Button

(push in)

Dial Button

(push in)

Dial Button

(turn left)

Dial Button

(turn right)

When the unit is not working, press this button to turn the timer on.

When the unit is working, press this button to turn the timer off.

Turning the dial left decreases the room temperature - /time hours-.

Turning the dial right increases the room temperature + /time hours+.

MULTI-COLOR DISPLAY

A.

Auto Mode

B.

Cool Mode

C.

Dehumidify Mode

D.

Fan Mode

E.

Heat Mode(if only cooling not work)

F.

Fan Speed (Low, High, Medium)

G.

Compressor is on F

H.

Swing Mode

I.

Sleep Mode

J.

Temperature and Timer

K.

Time On

L.

Time Off

M.

Water full

A B C D E K L

H G M I J

11

CONTROL PANEL FUNCTIONS

ON/OFF( POWER ) BUTTON

Starts or stops the unit.

MODE BUTTON

Press to select the operating mode:

Fan Mode

Air Conditioning Mode

Heating Mode

Dehumidifying Mode

Auto Mode

FAN BUTTON

Press to select the fan speed: High, Medium, and Low.

The fan speed can be visually distinguished by the number of the digital air segments (follow arrow above) flow out from the windmill fan image on the multi-colour display.

TEMPERATURE

When in cooling or heating mode, the desired temperature can be selected by pressing the

and

buttons. The multi-colour display flashes the temperature while it is being set. The multi-colour display shows the set temperature when it is not in temperature setting mode.

The multi-colour display can show either Celsius or Fahrenheit. Press the

and

buttons simultaneously to change the display from Celsius to Fahrenheit or vice versa.

TIMER

To set the auto start time, press the Timer on button until the multi-colour display shows a flashing “ ”.

Press the

and

buttons to change the clock to the desired time for the unit to automatically start. To set the auto stop time, press the Timer Off button and the multi-colour display will show a flashing “ ”. Press the

and

buttons to change the clock to the desired time for the unit to automatically stop. The light will flash for 3 seconds to activate the timer you programmed.

TIME DISPLAY

In the diagram above, the letter “J” points to the adjustable time display. To adjust the time, Press FAN, SPEED and SWING together (at the same time), then press UP to adjust the hours, and press DOWN to adjust the minutes.

SWING

To start horizontal oscillation, press the Swing button once. ‘ or ’ icon will appear on the multi-colour display. To stop oscillation, press the Swing button again. Vertical air flow direction can be adjusted manually.

TEMPERATURE DIAL (PAC18)

When in cooling or heating mode, the desired temperature can be selected by turn left and turn right buttons. The multi-colour display flashes the temperature while it is being set. The multi-colour display shows the set temperature when it is not in temperature setting mode.

The multi-colour display can show either Celsius or Fahrenheit. Turn left and turn right buttons simultaneously to change the display from Celsius to Fahrenheit or vice versa.

TIMER DIAL (PAC18)

When the unit is not working turn down dial to set the auto start time, until the multi-colour display shows a flashing “ ”. when the unit is working turn down dial to set the auto stop time, press the Timer Off button and the multi-colour display will show a flashing “ ”. Turn left and turn right buttons to change the clock to the desired time for the unit to automatically stop. The light will flash for 3 seconds to activate the timer you programmed.

12

OPERATION USING THE CONTROL PANEL

COOLING

1.

Properly install the exhaust hoses.

2.

Plug the power cord into a grounded outlet.

3.

Turn on the unit by pressing the On/Off button on the control panel.

4.

Press the Mode button until “ or ” icon appears on the multi-colour display.

5.

Press the

or

buttons until the desired temperature appears on the multi-colour display.

The temperature ranges from 61 ° F - 88 ° F (16 ° C - 31 ° C).

6.

Select the fan speed by pressing the Fan button.

NOTE : During hot days, the unit will cool off the room most efficiently by setting the temperature at the lowest and the fan speed at the highest. Reducing the length of the exhaust hoses, insulating the exhaust hoses, and keeping direct sunlight to a minimum will also improve the cooling efficiency.

DEHUMIDIFYING

1.

Properly install the exhaust hoses.

2.

Plug the power cord into a grounded outlet.

3.

Turn on the unit by pressing the On/Off button on the control panel.

4.

Press the Mode button until the “ or ” icon appears on the multi-colour display.

NOTE : The unit operates at low fan speed during dehumidifying. The unit cools the room slightly during dehumidification.

Keep the windows and the doors closed to aid in the effectiveness of the unit in removing the moisture from the room.

NOTE : The unit will not dehumidify when the room temperature is lower than 61 ° F.

FAN MODE

1.

Plug the power cord into a grounded outlet.

2.

Turn on the unit by pressing the On/Off button on the control panel.

3.

Press the Mode button until “ ” icon appears on the multi-colour display.

4.

Select the fan speed by pressing the Fan button.

NOTE : When the unit is running on fan mode, the exhaust hoses are inoperative and are not required.

HEATING

1.

Plug the power cord into a grounded outlet.

2.

Turn on the unit by pressing the On/Off button on the control panel.

3.

Press the Mode button until “ ” icon appears on the multi-colour display.

4.

Press the

or

button until the desired room temperature appears on the multi-colour display. The temperature ranges from 61 ° F - 88 ° F (16 ° C - 31 ° C).

5.

Select the fan speed by pressing the Fan button. It is recommended to use the low fan speed.

NOTE: When the unit is running on heating mode, the exhaust hose is operative the same way as cooling mode.

AUTO MODE

1.

Properly install the exhaust hoses.

2.

Plug the power cord into a grounded outlet.

3.

Turn on the unit by pressing the On/Off button on the control panel.

4.

Press the Mode button until the “ or

5.

Press the Fan button to select the fan speed.

” icon appears on the multi-colour display.

13

During the Auto mode, The unit operates in dehumidifying mode when the room temperature is between 68 ° F -

73 ° F. The unit operates in cooling mode when the room temperature is above 73 ° F. You may use the timer with the Auto mode.

SLEEP MODE

(This mode can only be programmed from the remote control.)

1.

The air conditioner will need to be in operation.

2.

Press the Sleep button. The “

3.

The fan motor runs at low speed.

” icon appears on the multi-colour display.

4.

When in cooling mode, the temperature will increase 1 ° F per hour during the first two hours. Then the temperature will stay 2 ° F higher than the originally set temperature for 6 hours. 6 hours later, the unit will shut down.

5.

When in dehumidify mode, the temperature will not change.

NOTE: If the unit is turned off during cooling, dehumidifying, or heating and then restarted, there will be a 3 minute delay before the compressor will turn back on to prolong the life of the compressor. Once the power recovers and the compressor restarts, the unit will return to the original working mode.

REMOTE CONTROL & OPERATION (PAC15/18 ONLY)

The remote control provided with the unit can be used to operate the portable air conditioner. The remote control uses

2 AAA batteries (provided). Install the batteries before using the remote control.

The remote control can be used to do all the operations that can be programmed from the control panel.

The LCD display on the remote control can show either Celsius or Fahrenheit. Press the + and - keys simultaneously to change the display from Celsius to Fahrenheit or vice versa.

14

WATER DRAINAGE

When the unit is in cooling mode, unwanted water is extracted from the air. Most of this water is re-used to cool the unit and make it run more efficiently. When the unit is used in extremely humid environments, water will collect in a water container at the bottom of the unit. When the water container is full, the compressor will stop but the fan will continue to run.

When the water container is full, the unit will display ‘FULL or ’ on the control panel until the tank is emptied. To resume operation, empty the water container according to the following steps:

1.

Turn the unit off. Do not move the unit when the water container is full.

2.

Place the drain pan accessory under the drainage port at the back of the unit.

3.

Remove the rubber plug from the drain hole. The condensate water will drain out automatically. When the drain pan is full, replace the rubber plug into the drainage hole to stop the water flow. Empty the drain pan. Repeat until all the water is emptied.

4.

Once the water container has been emptied, replace the rubber plug into the drain hole firmly. Do not allow the water to drip continuously into the drain pan, as it might easily overflow.

NOTE: In heating mode, the drain pipe accessory must be used to empty the water container.

1.

Remove the rubber plug and keep for future use.

2.

Connect the drain tube accessory to the drain hole. Place drain pan at end of drain tube; water will drain out automatically during operation.

HIGH HUMIDITY WATER RELEASING FEATURE (PAC18)

When used in high humidity areas, more water can be created than the unit can re-use, when this happens the internal tank will fill up, cooling will stop and the unit requires emptying. The PAC18 model features a water releasing function, this allows you to connect a water drain pipe to the upper water removal port and thus allows continuous use of the machine without fear of it turning itself off. When this feature is desired connect the 3m water pipe to the port then drain the water (making sure the water goes downhill!), if this feature is not required please ensure the plastic screw lid is tightly secured to the upper drainage port.

Automatic freeing port position following chart :

Automatic freeing port

Automatic freeing port

15

MAINTENANCE

Always turn off and unplug the unit before cleaning to avoid electrical shock.

CLEANING THE HOUSING

Wipe the surface of the unit with a soft, damp cloth. Do not use abrasive chemicals or detergents to clean the surface of the unit, as the unit may become scratched or damaged.

Avoid direct exposure to sunlight as this may change the surface colour.

CLEANING THE FILTER

Slide the filters out from the side of the unit.

Immerse the filter gently in warm water with a mild detergent. Rinse thoroughly and dry before replacing.

An unclean air filter reduces air volume. The filter should be cleaned every two weeks.

END OF SEASON STORAGE

Turn off and unplug the unit.

Drain all condensate water from the water container.

Turn the unit to fan mode for a couple of hours to completely dry out the inside.

Clean the filter.

Wrap the cord around the cord hooks.

It is recommended that the unit be packed in its original carton for storage.

Store in a dry location.

16

TROUBLESHOOTING

Before seeking repair or service, please check the following:

PROBLEM POSSIBLE CAUSE REMEDY

Unit does not operate or only runs in fan mode.

Is the unit plugged in?

Is the main power supply on?

Securely plug the power cord into the wall outlet.

Re-establish the main power supply.

Is the water container full indicator light on? Empty the water container.

Is the timer set? Change timer settings.

Cooling efficiency is not satisfactory.

Is the air inlet or outlet blocked? Clear the blocking.

Is there any other heat source in the room? Move the heat source.

Are the air filters dirty? Clean the air filters.

Is the temperature setting suitable?

Is the fan speed set at low?

Change the temperature setting.

Increase the fan speed.

Unit is noisy or vibrates.

Is the machine positioned unevenly on a level surface?

Place the unit on a level surface.

Is the voltage from the power source correct?

Use a proper power source.

The unit starts and stops frequently.

Is the exhaust hose positioned incorrectly?

Position the exhaust hose correctly and keep the exhaust hose straight as possible.

ERROR MESSAGES

Diagnostic system indicators appear if any of the following interrupts operation of the unit. The unit may require simple maintenance or repair by a qualified service technician.

CODE DIAGNOSIS ACTION

FAULT E1 Faulty room temperature sensor Contact customer service for repair or service.

FAULT E2 Faulty inside sensor. Contact customer service for repair or service.

FAULT E3 Internal frost in the unit. Wait for unit to defrost

FAULT E4 Unit malfunctions. Contact customer service for repair or service.

TECHNICAL SUPPORT / CUSTOMER SERVICE CONTACT

If you require Technical Support or Customer Service from Climachill, please contact us in the following way: -

Email: [email protected]

Telephone: 01273 803820

17

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement