Enerco HS155IR Heatstat is a direct-fired portable heater that offers powerful and efficient heating solutions for various indoor spaces. With a maximum heating output of 154,237 BTU/h, it can quickly and effectively warm up large areas. Ideal for construction sites, workshops, garages, and other well-ventilated environments, the HS155IR utilizes heating oil to generate clean, radiant heat without the need for electricity. It features a built-in thermostat for precise temperature control and safety mechanisms like flame control and overheat protection to ensure safe operation.
advertisement
READ INSTRUCTIONS CARE FULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
HEATSTAR
BY ENERCO
HS155IR
DIRECT FIRED INFRARED
PORTABLE HEATER
WARNING :
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
— Service must be performed by a qualified service agency.
This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to page 5.
ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001 07/11 50014
warning:
YoUR SAFeTY IS IMPoRTANT To YoU AND To oTHeRS,
So PleASe ReAD THeSe INSTRUCTIoNS BeFoRe YoU oPeRATe THIS HeATeR.
general HaZard warning:
FAIlURe To CoMPlY WITH THe PReCAUTIoNS AND
INSTRUCTIoNS PRoVIDeD WITH THIS HeATeR, CAN
ReSUlT IN DeATH, SeRIoUS BoDIlY INJURY AND
PRoPeRTY loSS oR DAMAGe FRoM HAZARDS oF FIRe, eXPloSIoN, BURN, ASPHYXIATIoN, CARBoN MoNoX-
IDe PoISoNING, AND/oR eleCTRICAl SHoCK.
oNlY PeRSoNS WHo CAN UNDeRSTAND AND FolloW
THe INSTRUCTIoNS SHoUlD USe oR SeRVICe THIS
HeATeR.
IF YoU NeeD ASSISTANCe oR HeATeR INFoRMATIoN
SUCH AS AN INSTRUCTIoNS MANUAl, lABelS, eTC.
CoNTACT THe MANUFACTUReR.
warning:
NoT FoR HoMe oR ReCReATIoNAl VeHICle USe warning:
FIRe, BURN, INHAlATIoN, AND eXPloSIoN HAZARD.
KeeP SolID CoMBUSTIBleS, SUCH AS BUIlDING MA-
TeRIAlS, PAPeR oR CARDBoARD, A SAFe DISTANCe
AWAY FRoM THe HeATeR AS ReCoMMeNDeD BY THe
INSTRUCTIoNS NeVeR USe THe HeATeR IN SPACeS
WHICH Do oR MAY CoNTAIN VolATIle oR AIRBoRNe
CoMBUSTIBleS, oR PRoDUCTS SUCH AS GASolINe,
SolVeNTS, PAINT THINNeR, DUST PARTICleS oR UN-
KNoWN CHeMICAlS. warning: the state of california requires the following warning:
COMBUSTION BY-PRODUCTS PRODUCED WHEN US-
ING THIS PRoDUCT CoNTAIN CARBoN MoNoXIDe,
A CHeMICAl KNoWN To THe STATe oF CAlIFoRNIA
To CAUSe CANCeR AND BIRTH DeFeCTS (oR oTHeR
RePRoDUCTIVe HARM).
warning:
read tHe instructiOns giVen in tHis
Manual BeFOre using tHe appliance.
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE
FUelS.
• THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE
IS CoNNeCTeD MUST CoMPlY WITH All SAFeTY
ReGUlATIoNS IN FoRCe. A ReSIDUAl CURReNT
CIRCUIT BReAKeR MUST Be PRoVIDeD oN THe MAIN
DISTRIBUTIoN BoARD.
• UNPLUG THE HEATER BEFORE ATTEMPTING ANY
SeRVICe oR MAINTeNANCe.
• ALWAYS CHECK THE POWER SUPPLY CABLE BEFORE
USe. IT MUST NoT Be BeNT, CRUSHeD, oR ANYWAY
DAMAGeD.
• THE POWER SUPPLY CABLE MUST BE REPLACED ONLY
BY QUAlIFIeD PeRSoNNel.
• ONLY USE AN ORIGINAL H07RN-F POWER CABLE
WITH WATeRPRooF PlUG.
• DO NOT TOUCH THE EXHAUST GAS OUTLET. DANGER oF BURNS!
cOntents
WARNINGS .................................................................................. 2
SPeCIFICATIoNS ........................................................................... 3 oPeRATIoN ................................................................................. 4
SAFeTY DeVICeS .......................................................................... 4
MAINTeNANCe ............................................................................ 5
TRoUBleSHooTING .................................................................... 6
WIRING DIAGRAMS ..................................................................... 7
PARTS lIST ................................................................................... 8 eNeRCo GRoUP, INC. |Direct Fired Portable Heater
2
operating Instructions and owner’s Manual
IMPORTANT
Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods or persons due to improper use of units.
GENERAL RECOMMENDATIONS
The heater described in this manual is a portable oil-fueled infrared heat generator running on heating oil.
Its easy handling and large fuel tank allow it to be used locally and temporarily with complete stand-alone operation. The area to be heated is therefore hit by an even and uniform flow of heat, as can be seen by the shape of the irradiation cone (18), without air movement.
The unit is a direct combustion hot generator that works by sending both hot air and combustion products in the room you wish to heat: all the necessary precautions must therefore be taken to guarantee a sufficient exchange of air.
Always follow local ordinances and codes when using this heater:
• Read and follow this owner’s manual before using the heater;
• THE INSTALLATION OF THE UNIT SHALL BE IN
ACCORDANCE WITH THE REGULATIONS OF THE
AUTHORITIES HAVING JURISDICTION. Also, as a recommended installation practice reference should be made to the current issue of CSA B139, Installation Code for Oil Burning
Equipment in Canada and NFPA 31 Standard for the Installation of Oil-Burning Equipment In the USA;
• Use only in places free of flammable vapours or high dust content;
• Never use heater in immediate proximity of flammable materials
(the minimum distance must be 10 feet);
• Make sure fire fighting equipment is readily available;
• Make sure sufficient fresh outside air is provided according to the heater requirements. Direct combustion heaters should only be used in well vented areas in order to avoid carbon monoxide poisoning;
• A rough estimate of opening required for each gallon (US) of capacity is three square foot at heater level, for direct-fired heaters;
• The heater is installed and connected to an electrical switchboard;
• Ensure that the machine resting surface or ground is not made of flammable material;
•
Minimum clearances from combustible material must be:
30” from side and rear (air inlet) of heater
80” from ceiling
40” on air outlet of heater.
• Never block air inlet (rear) or air outlet (front);
• In case of very low temperatures add kerosene to the heating oil;
• Connect the power cord to the mains and wait 15 min at least be fore starting heater, to allow pre-heated filter warming heating oil inside the filter;
• Make sure heater is always under surveillance and keep children and animals away from it;
• Before starting the heater always check free rotation of ventilator;
• Heater is not ductable.
• Unplug heater when not in use.
TECHNICAL SPECIFICATIONS
Max heating output
Fuel consumption
Power supply
Power consumption
Nozzle
Pump pressure
Adjustment of combustion air flap
Tank capacity
Noise level at 1 m
Dimensions, L x W x H
Weight
Phase
Voltage
Frequency
PSI
[N°]
[USgal]
[dBA]
[in]
[lb]
[BTU/h]
[gal/h]
FIRE 155
154.237
1,11
[V]
[Hz]
[W]
1
120
60
440
[USgal/h] Delavan 0,85 - 80° W
174
2
17.17
72
55.5 x 28.03 x 41.5
161
ENERCO GROUP, INC. |Direct Fired Portable Heater
3
Operating Instructions and Owner’s Manual
SAFETY DEVICES
The unit is fitted with an electronic flame control box. In case of malfunction this box will cut in and stop the heater, at the same time the pilot lamp in the control box reset button (13) will light up.
WARNING
The reset push-button emits a different colour light, depending on the state of the machine:
• green, when the machine is running regularly;
• red, when the machine is in safety lock-out mode: to restart it , the reset button (13) must be pressed.
Heaters are also equipped with an overheat thermostat safety cut out which will stop the heater in case of overheating. This thermostat will reset automatically but you will have to depress button (13) on control box before being able to restart the heater.
OPERATION
Before any attempt of starting the heater is made, check that your electrical supply conforms to the data on the model plate.
WARNING
M ains must be fitted with a thermo-magnetic differential switch.
Unit plug must be linked to a socket with a mains switch.
The hot generator must be placed on a flat, stable and level surface to avoid machine tipping and/or gas oil leakage from the tank fuel cap.
The flow of heat can be directed upward with an approximately 10° angle: loosen the two locking knobs (A) and tilt the combustion unit by pressing on the handle until the desired angle is reached, then lock the knobs (A) by tightening.
Before any attempt of starting the heater is made, check that your electrical supply conforms to the data on the model plate.
Control Board
1 3 4 2
O N
5
0
O N
1 RESET BUTTON WITH CONTROL LAMP
2 CONTROL LAMP
3 MAIN SWITCH
4 ROOM TH ERMOSTAT PLUG
5 POWER CORD
Gap of Electrodes
WARNING
Before start-up, always ensure the guard (B) has been completely pulled out, so as to guarantee maximum protection of the machine resting surface. Clearances
The following minimum safety clearances from materials or objects in the surroundings of the heater must be ensured:
Sides 30 in.
Top 80 in.
Air Inlet 30 in.
Air outlet 40 in.
•
•
• the room where the heater is operated.
• The air inlet and outlet must never be blocked for any reason.
ENERCO GROUP, INC. |Direct Fired Portable Heater
4
Operating Instructions and Owner’s Manual
WARNING
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE FUELS.
• STOP HEATER BEFORE ADDING FUELS.
• ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME
• DO NOT USE EXTERNAL FUEL SOURCE.
• DO NOT OPERATE HEATER WHERE FLAMMABLE LIQUIDS
OR VAPORS MAY BE PRESENT.
• DO NOT START HEATER WHEN CHAMBER IS HOT
• DO NOT START HEATER WHEN EXCESS FUEL HAS ACCUMU -
LATED IN THE CHAMB ER.
• DO NOT PLACE COOKING UTENSILS ON TOP OF THE
HEATER.
• PLUG ELECTRICAL CORD INTO A PROPERLY GROUNDED
THREE-PRONG RECEPTACLE.
The generator can only work automatically when a control device, such as for example a thermostat or a timer, is connected to the generator. Connection to the generator is made by removing the socket cover(4) and inserting the thermostat plug.
To start the machine you must:
•If connected to the thermostat, turn the switch to (ON + );
•If not connected to the thermostat, turn the switch to (ON).
When unit is started for the first time or is started after the oil tank has been totally emptied, the flow of oil to the burner may be impaired by air in the circuit. In this case the control box will cut out the heater and it might be necessary to renew the starting procedure once or twice by depressing the reset button (1).
Should the heater not start, check that oil tank is full and depress reset button (1).
Should the heater still not work, please refer to chapter
“OBSERVED FAULTS, CAUSES AND REMEDIES”.
STOPPING THE HEATER
Set main switch (3) on “0” position or turn thermostat or other control device on lowest setting.
-
The flame goes out and the fan continues to work for approx.
90sec. cooling the combustion chamber.
SAFETY DEVICES
The unit is fitted with an electronic flame control box. In case of malfunction this box will cut in and stop the heater, at the same time the pilot lamp in the control box reset button (1) will light up.
Heaters are also equipped with an overheat thermostat safety cutout which will stop the heater in case of overheating. This thermostat will reset automatically but you will have to depress button (1) on control box before being able to restart the heater.
TRANSPORT
WARNING
• nate reason of overheating.
-
Before heater is moved it must be stopped and unplugged. Before moving the heater wait till it has totally cooled off and make sure oil tank cap is securely fixed.
The hot air generators with wheels must be wheeled. The suspended version which has no wheels must be transported with adequate machinery.
MAINTENANCE
Preventive and regular maintenance will ensure a long trouble free life to your heater.
WARNING
• Never service heater while it is plugged in, operating or hot.
Severe burns or electrical shock can occur.
Every 50 hours of operation: disassemble filter and wash with clean oil, remove upper body parts and clean inside and ventilator with compressed air, check correct attachment of H.V. connectors to the electrodes and check H.V. cables, remove burner assembly, clean and check electrode settings, adjust according to scheme
“GAP OF ELECTRODES”.
ENERCO GROUP, INC. |Direct Fired Portable Heater
5 5
Operating Instructions and Owner’s Manual
TROUBLESHOO TING
O B S E R V E D F A U L T C A U S E R E M E D Y
• Motor does not start, no ignition
• No electrical current
• Wrong setting of room thermostat or other control
(thermostat and clock)
• Thermostat or other control defective
• Check mains
• Check proper positioning and functioning of switch
• Check fuse
• Check correct setting of heater control. If thermostat, make sure selected temperature is higher than room temperature
• Replace control device
• Electrical motor defective
• Electrical motor bearings defective
• Burned out condenser
• Electric ignitor defective
• Replace electrical motor
• Replace electrical motor
• Replace condenser
• Check connection of H.T. Ieads to electrodes and transformer
• Check electrodes setting (see scheme Fig. 2)
• Check electrodes for cleanliness
• Replace H.T. transformer
• Flame control box defective
• Motor starts, no ignition or cuts out
• Photocell defective
• Not enough or no fuel at all at burner
• Replace control box
• Clean or replace photocell
• Check state of motor-pump plastic coupling
• Check fuel line system including fuel filter for possible leaks
• Clean or replace oil nozzle
• Motor starts, heater emits smoke
• Solenoid defective
• Not enough combustion air
• Too much combustion air
• Fuel contaminated or contains water
• Air leaks in fuel circuit
• Check electrical connection
• Clean or replace solenoid
• Make sure air inlet and outlet are free
• Check setting of combustion air flap
• Clean burner disc
• Check setting of combustion air flap
• Drain fuel in tank and replace with clean fuel
• Clean or replace oil filter
• Heater does not stop
• Not enough fuel at burner
• Too much fuel at burner
• Solenoid defective
• Check fuel line and filter for possible leaks
• Check pump pressure
• Clean or replace fuel nozzle
• Check pump pressure
• Replace nozzle
• Replace solenoid coil or complete solenoid
If heater is still not working properly, please revert to nearest authorized dealer.
ENERCO GROUP, INC. |Direct Fired Portable Heater
6
Operating Instructions and Owner’s Manual
WIRING DIAGRAM
AP CONTROL BOX
TA ROOM THERMOSTAT PLUG
ST PILOT LAMP
LI1 OVERHEAT THERMOSTAT
EV1 SOLENOID VALVE
FO PHOTOCELL
CO CAPACITOR
MV FAN MOTOR
FUA FUSE
LF ANTI-JAMMING FILTER
RV MAIN SWITCH
RF HEATED FILTER
>>>OPTIONAL
ENERCO GROUP, INC. |Direct Fired Portable Heater
7
Operating Instructions and Owner’s Manual
ENERCO GROUP, INC. |Direct Fired Portable Heater
8
Operating Instructions and Owner’s Manual
ENERCO GROUP, INC. |Direct Fired Portable Heater
9
Operating Instructions and Owner’s Manual
ENERCO GROUP, INC. |Direct Fired Portable Heater
10
Operating Instructions and Owner’s Manual
ENERCO GROUP, INC. |Direct Fired Portable Heater
11
Operating Instructions and Owner’s Manual
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTI ONS CARE FULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
HEATSTAR
BY ENERCO
WARNING :
USE ONLY MANUFACTUR ER’S R EPLACEMENT PARTS. US E OF ANY OTHER PARTS
COULD CAUSE INJURY OR DEATH. R EPLACEMENT PARTS AR E ONLY AVAI LABLE
DIRECT FROM THE FACTORY AND MUST B E INSTALLED BY A QUA LIFIED SERVICE
AGENCY.
PARTS ORDERING INFORMATI ON:
PURC HASING : Accessories may be purchased at any Mr. Heater/HeatStar local dealer or direct from the factory
FOR INFORMATI ON REGARDING SERVICE
Please call Toll-Free 800-251-0001 • www.enerco-mrheater.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Email to: [email protected]
Please include the model number, date of purchase, and description of problem in all communication.
LIMITED WARRANTY
The company warrants this product to be free from imperfections in material or workmanship, under normal and proper use in accordance with instructions of The Company, for a period of one year from the date of delivery to the buyer. The Company, at its option, will repair or replace products returned by the buyer to the factory, transportation prepaid within said one year period and found by the Company to have imperfections in material or workmanship.
If a part is damaged or missing, call our Technical Support Department at 800-251-0001.
Address any Warranty Claims to the Service Department, Enerco Group, Inc., 4560 W. 160TH
ST., Cleveland, Ohio 44135. Include your name, address and telephone number and include details concerning the claim. Also, supply us with the purchase date and the name and address of the dealer from whom you purchased our product.
The foregoing is the full extent of the responsibility of the Company. There are no other warranties, express or implied. Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability. In no event shall the Company be liable for delay caused by imperfections, for consequential damages, or for any charges of the expense of any nature incurred without its written consent. The cost of repair or replacement shall be the exclusive remedy for any breach of warranty. There is no warranty against infringement of the like and no implied warranty arising from course of dealing or usage of trade. This warranty will not apply to any product which has been repaired or altered outside of the factory in any respect which in our judgment affects its condition or operation.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from state to state.
Enerco Group, Inc.
reserves the right to make changes at any time, without notice or obligation, in colors, specifications, accessories, materials and models.
ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
Mr. Heater is a registered trademark of Enerco Group, Inc.