SPECIFICATIONS: (All at 23°C±5°C,
≤
80% R.H.)
AC VOLTAGE:
DC VOLTAGE:
AC CURRENT:
APPA 32
Ranges:
Resolution:
Accuracy:
Input Impedance: 10M
Ω
//<100pF
Overload Protection: 600Vrms
Conversion Type: Average sensing RMS indicating
Ranges:
Resolution:
APPA 31 APPA 30T APPA 39T APPA33/33R APPA 35N/35R APPA 33 II /33R II APPA 39AC/39AR
400V,600V 400V,600V 600V 400V, 400V
APPA 36 II /36R II APPA 30 /30R APPA 39/39R APPA 39MR
, 600V
0.1V 0.1V 0.1V 0.1V 0.1mV 0.1mV
±(1.2%+5d),40Hz~500Hz ±(1.2%+5d),40Hz~500Hz ±(1.2%+3d),40Hz~500Hz ±(1.2%+5d),40Hz~500Hz ±(1.5%+5d),40Hz~500Hz ±(1.5%+5d),40Hz~500Hz
• • • • •
0.1V
±(1.2%+5d),50Hz~500Hz
• •
•
33 • 33R True RMS
• • • • • 850V rms
35N • 35R True RMS 33 II • 33R II True RMS 39AC • 39AR True RMS 36 II • 36R II True RMS 30 • 30R True RMS 39 • 39R True RMS True RMS
400V, 1000V 400mV~600V 400mV~600V 400V, 1000V
0.1V 0.1mV
0.1mV 0.1V
Accuracy:
Input Resistance: 10M
Ω
Overload Protection: 600V rms
Ranges: 400A
Resolution:
Accuracy:
±(0.7%+5d)
11M
Ω
1000V DC
200A,600A
400A,1000A(39AR)/1200A(39AC)
±(0.7%+2d)
•
•
400A,600A
±(0.5%+2d) ±(0.7%+2d)
• •
• 1000V DC
40A,300A 400A,1000A 400A, 1000A 100A,600A 40A,300A 100A.1000A 400A,600A
1mV/A 10mV/A,1mV/ A
50~60Hz 45Hz~400Hz
10mV/A,1mV/ A 10mV/A,1mV/ A 0.1A
40Hz~400Hz 40Hz~400Hz 50Hz~60Hz
0.1A
50Hz~60Hz
0.1A
50Hz~60Hz
0.1A 100mA
50Hz~60Hz 50Hz~60Hz
10mA
50Hz~60Hz
0.1A 0.1A
40Hz~400Hz 40Hz~400Hz
±(1.9%+0.5A),0A~350A ±(2%+2A),0A~ 100A ±(1.0%+0.1A),0A~ 40A ±(1.9%+2A), 0A~100A ±(1.9%+5d),0A~400A ±(1.9%+5d) ±(1.9%+5d),200A ±(1.9%+8d), 0A~40A
±(3.2%+1A),350A~400A ±(2%+2A),100A~400A ±(1.0%+1A),40A~200A ±(1.9%7A),100A~400A ±(2.9%+5d),400A~600A
±(1.9%+7d),0A~40A ±(1.0%+5d),0A~4A ±(1.9%+8d),0A~40A ±(1.5%+5d), 0A~600A
±(1.5%+5d),0A~400A ±(1.9%+5d), 40A~400A ±(1.9%+5d),40A~400A ±(1.0%+3d),4A~200A ±(1.9%+7d),40A~400A 40Hz~200Hz
±(3%+2A),400A~600A ±(1.9%+2A),200A~300A ±(2.9%+5A),400A~1000A
400A
±(2.5%+5d),400A~600A
±(2.9%+5d), 400A~1000A(39A)
±(2.9%+5d), 400A~1200A(39A)
±(1.9%+10d),400A~600A ±(3%+3d),200A~300A ±(2.9%r+5d),400A~1000A ±(2.5%r+5d), 600A~1000A
61Hz~400Hz 40HZ~1KHZ
±(2.5%+7d),0A~40A ±(2.0%+7d),0A~4A
±(2.5%+5d),40A~400A ±(1.5%+5d),4A~200A
Conversion Type: Average sensing RMS indicating
FREQUENCY COUNT: Ranges:
Accuracy:
DC CURRENT: Ranges:
Resolution:
Accuracy:
RESISTANCE: Ranges:
Load Impedance:
Position Error:
Type of Sensing :
Resolution:
Accuracy:
Overload Protection:
CONTINUITY TEST: Threshold: < 200 Ω approximate
Indicator: 2KHz tone buzzer
AC and DC
Output Voltage: AC/DC,10mV/A in 100A, 1mV/A in 1000A
Current transformer sensing
Hall effect sensing for AC and DC
100A,600A 40A,300A 100A,1000A
10mV/A,1mV/A 10mV/A,1mV/A 10mV/A,1mV/A
±(2%+2A),0A~100A ±(1.0%+0.1A),0A~40A ±(2.9%+2A),0A~100A
±(2%+2A),100A~400A ±(1.0%+1A),40A~200A ±1.9%+7A),100A~400A
±(3%+2A),400A~600A ±(1.9%+2A),200A~300A ±(2.9%+5A),400A~600A
±(2.5%+10d),400A~600A ±(5%+5d),200A~300A
33 • 33R True RMS 35N • 35R True RMS 33 II • 33R II True RMS 39AC • 39AR True RMS 36 II • 36R II True RMS 30 • 30R True RMS 39 • 39R True RMS True RMS
20Hz~10KHz 20Hz~10KHz
±(0.5%+3d) ±(0.5%+3d)
4K
Ω
1
, 40K
Ω
Ω
±(2% rdg + 9d)
600V rms
• <100 Ω approximate <50 Ω approximate <100 Ω approximate
• • • •
100K Ω min 100K Ω min
•
±1%rdg ±1%rdg ±1%rdg
AC 1mV per 1A
AC/DC, 10mV/A in 100A,1mV/A in 600AAC/DC, 10mV/A in 40A,1mV/A in 300A
•
•
• • •
4K
Ω
, 40K
Ω
1
Ω
1
Ω
1
Ω
±(1.9% rdg + 8d) ±(1.5% rdg + 2d)
600V rms 600V rms
•
2000
Ω
4K
Ω
, 40K
Ω
±(2% + 9d)
600V rms
• •
400A,600A 40A,300A 400A,1000A 400A,1000A
100mA 10mA 0.1A 0.1A
±(1.5%+10d),0A~40A ±(1.0%+2d),0A~200A ±(2.9%+8d),0A~100A ±(1.0%+3d), 0A~600A
±(1.5%+7d),40A~400A ±(2.0%+2d),200A~300A ±(1.9%+5d),100A~400A ±(1.9%+5d), 600A~1000A
±(1.9%+10d),400A~600A
400
Ω
~40M
Ω
400
Ω
~40M
Ω
±(2.9%+5d),400A~1000A
4K
Ω
, 40K
Ω
0.1
Ω
0.1
Ω
±(1.2%+6d),0
Ω
~400
Ω
±(1.2%+6d),0
Ω
~400
Ω
±(.0.9%+3d),400
Ω
~40K
Ω
±(.0.9%+3d),400
Ω
~40K
Ω
±(1.2%+3d),40K Ω ~4M Ω ±(1.2%+3d),40K Ω ~4M Ω
±(2.5%+5d),4M Ω ~40M Ω ±(2.5%+5d),4M Ω ~40M Ω
1
Ω
±(1.0%g+2d)
600Vrms 600Vrms 600V rms
<50 Ω approximate <50 Ω approximate <100 Ω approximate
• • •
±1%rdg
•
±1%rdg ±1%rdg ±1%rdg
• • •
GENERAL:
Display: LCD digital readout
Measuring Rate: Times per second
Overrange indication:
Low Battery Indicaton:
Auto Power Off: Approx 30 minutes
Operating Temperature: 0°C~50°C, ≤ 80% R.H.
Storage Temperature: -20°C~60°C
Temperature Coefficient: 0.2x(spec. Acc’y)/°C,<18°C or >28°C
Shock Proof: 4 feet drops
Safety: IEC 61010 and designed to meet UL 3111 specifications
Maximum Conductor Size:
Maximum Jaw Opening:
Maximum Busbar Size:
Power Requirement: Single 9V battery (NEDA 1604,IEC 6F22)
Battery Life: In hours (Alkaline battery)
Size: WxLxD in mm
Weight: In grams
Included with Instrument: Safety test leads
Battery(ZnC)
Coiled cable output plugs
User’s manual
Carrying Case
•
•
•
•
CAT. II 600V
ø29mm
30mm
Red LED
•
•
•
•
CAT. II 600V
ø34mm
38mm
Red LED
4000 count
4 T/sec
"OL"
Red LED
• •
• •
•
•
•
• • •
• • •
CAT. III 600V CAT. III 1000V CAT. II 600V CAT. II 600V
ø22mm ø51mm ø40mm ø29mm
25mm 53mm 42mm 30mm
250
Installed
•
•
20x40mm 24x60mm
•
45
72x148x36, w/o cable 60x203x27,w/o cable
380
• •
66 66
65.5x185x40,w/o cable 90x232x32,w/o cable
320 420
•
200
88x215x36
320
User supplied Installed Installed
•
Installed
Installed Installed Installed
• • • •
• • • •
4000 count
4 T/sec
"OL"
•
•
•
•
•
•
200
77x194x36
250
•
Installed
•
•
2000 count
2.5T/sec
"OL"
•
•
•
• •
0°C~45°C, ≤ 80%RH
•
•
•
• • 10 minutes
•
•
• •
• •
•
•
•
•
• •
• •
CAT. III 600V, CAT. II 1000V CAT. III 600V, CAT. II 1000V CAT. III 600V
ø34mm ø51mm ø35mm
37mm 53mm 45mm
•
•
•
•
CAT. II 600V CAT. III 1000V CAT. III 600V, CAT. II 1000V
ø22mm
25mm
ø51mm ø51mm
53mm 53mm
24x60mm
• •
200 200
76x200x41 105x268x42
360 420
•
Installed
•
Installed
40x15mm
• Alkaline AAA SIZE1.5Vx2
150 50
24x60mm 24x60mm
• •
40 40
82x208x41 66x192x27
360 205
106x240x40 100x265x42
420 420
• •
Installed
• •
Installed Installed (Installed)Alkaline
•
•
4000 count
4 T/sec
"OL"
•
•
4000 count
2 T/sec
"OL"
•
•
4000 count
2 T/sec
"OL"
•
•
4000 count 4000 count
2 T/sec 2 T/sec
" OL" " OL"
•
•
•
•
Specifictions subject to change without notice. Copyright © 2005 APPA Tech., Corp. All rights reserved
APPA 30 Series
The State-of-the-Art Clamp-On Measuring Instruments
Distrubuted by:
APPA TECHNOLOGY CORPORATION
9F, 119-1 Pao-Zong Rd., Shintien, Taipei, 231, TAIWAN
Tel: +886-2-29178820 Fax: +886-2-29170848
E-mail: [email protected]· http://www.appatech.com
ISO 9001 CERTIFIED Advanced Instrument Technology Made Easy
AC CURRENT TRANSDUCER
APPA 31
AC 400A capability
1.9% basic accuracy
Non-intrusive transducing
Up to 29mm diameter conductor
5 feet drop proof
Coiled cable output plugs
Ergonormicly designed jaw and trigger
Hand guard designed
Carrying case included
IEC 1010-1 CAT II 600V
AC/DC CURRENT TRANSDUCER
APPA 32
AC/DC 600A capability
Dual Hall sensor
2.0% basic DCA/ACA accuracy
Non-intrusive transducing
Up to 34mm dia conductor
Up to 20x40mm busbar
DCA zero adjust knob
Power on indicating
Battery low indicator
5 feet drop proof
Coiled cable output plugs
Hand Guard protection
Carrying case included
IEC 1010-1 CAT II 600V
APPA 30T
AC/DC 300A capability
Auto zero key for DCA
Red LED-Low battery indication
GreenLED-Power on indication
Coiled cable output leads
Insulated input jacks
Standard 9V battery
Up to 22mm dia. conductor
4 feet drop proof
Deluxe carrying case
Hand guard designed
IEC 1010-1 CAT. III 600V Safety Standard
APPA 39T
AC/DC 1000A capability
Auto zero key for DCA
Red LED-Low battery indication
GreenLED-Power on indication
Coiled cable output leads
Insulated input jacks
Standard 9V battery
Up to 51mm dia. (2”) conductor
Up to 24x60mm busbar
4 feet drop proof
Deluxe carrying case
Hand guard designed
IEC 1010-1 CAT. III 1000V Safety Standard
AC CURRENT/VOLTAGE/RESISTANCE CLAMP METER
APPA 35N
APPA 35R (True-RMS reading)
4000 count digital display
AC 400A, 600V Capability
Autoranging
1.2% basic ACV accuracy
1.9% basic ACA accuracy
1.9% basic OHM accuracy
Continuity buzzer
Up to 29mm (600MCM) conductor
600V circuit protection
Display hold function
Auto power off
4 feet drop proof
Insulated input jacks
Hand guard protection
Deluxe carrying case
IEC 1010-1 CAT II 600V
APPA 33
II
APPA 33R
II
(True-RMS reading)
2000 count large scale LCD display
AC 600 Amps capability
AC 600 Volts capability
2000 Ohms Resistance range
True RMS ACV/ACA (APPA33R II )
Continuity Beeper
Display Hold
Auto power off
600 Volts circuit protection
Insulated input jacks
Up to 34mm dia. (750MCM) conductor
4 feet drop proof
Protective carrying case
Hand guard designed
CAT. III 600V/CAT. II 1000V Safety Standard
APPA 39AC
APPA 39AR (True-RMS reading)
4000 count digital display
AC 1200A in specification
AC 1000A in specification (39AR)
1500A overload protection
AC 600A, DC 1000V capability
Autoranging
1.2% basic ACV accuracy
1.2% basic DCV accuracy
2% basic OHM accuracy
CONTINUITY beeper
True RMS reading in ACV/ACA
Up to 51mm dia. (2”) conductor
600V circuit protection
Display HOLD function
Auto Power Off
Insulated input jacks
Hand guard designed
Deluxe carrying case
IEC 1010-1 CAT. II 1000V
APPA 33
APPA 33R (True-RMS reading)
4000 count digital display
AC 600A, 600V Capability
Autoranging
1.2% basic ACV accuracy
1.9% basic ACA accuracy
1.9% basic OHM accuracy
Continuity beeper
Up to 40mm dia. (750MCM) conductor
600 Volts circuit protection
Display hold function
Auto power off
4 feet drop proof
Insulated input jacks
Hand guard designed
Deluxe carrying case
IEC 1010-1 CAT II 600V
AC/DC CURRENT CLAMP MULTIMETER
APPA 30
APPA 30R (True-RMS reading)
4000 count digital display
Autoranging
Dual Hall sensor
Nickel-Steel alloy jaw mechanism
AC/DC 300 Amps capability
AC/DC 600 Volts capability
0.5% basic DCV accuracy
1.5% basic ACV accuracy
1.0% basic DCA/ACA accuracy
0.9% basic OHM accuracy
Continuity Beeper
10mA resolution
Auto-Zeroing key for DCA
Data hold function
MAX hold function
Auto power off selectable
600V protection in every range
Up to 22mm dia (350 MCM) conductor
4 feet drop proof
Insulated input jacks
Hand guard designed
Deluxe carring case
IEC 1010-1 CAT II 600V
APPA 39MR (True-RMS reading)
4000 count digital display
AC/DC 1000A in specification, and 2000A overload protection
AC 600V, DC 1000V capability
Autoranging
Dual Hall sensor
Nickel-Steel alloy jaw mechanism
0.7% basic DCV accuracy
1.2% basic ACV accuracy
1.0% basic DCA/ACA accuracy
1.5% basic ACA accuracy
1.0% basic OHM accuracy
0.5% basic Hz accuracy
CONTINUITY beeper
True RMS reading in ACV/ACA
Frequency measurement through input jack or clamp-on
PEAK HOLD function
Auto-Zero key for DCA
Auto Power Off
Up to 51mm dia. (2”) conductor
Up to 24 x 60mm busbar
4 feet drop proof
Insulated input jacks
Hand guard designed
Deluxe carrying case
IEC 1010-1 CAT. II 1000V
APPA 36
II
APPA 36R
II
(True-RMS reading)
4000 count large scale LCD display
Autoranging
Dual Hall Sensor
AC/DC 600 Amps capability
AC/DC 600 Volts capability
40M Ohms Resistance range
True RMS ACV/ACA (APPA36R II )
Continuity Beeper
Display Hold
Maximum Hold
Auto-Zeroing Key for DCA
Auto power off selectable
600Volts Circuit protection
Insulated input jacks
Up to 35mm dia. (750MCM) conductor
Up to 40x15mm busbar
4 feet drop proof
Deluxe carrying case
Hand guard designed
CAT. III 600V Safety Standard
APPA 39
APPA 39R (True-RMS reading)
4000 count digital display
AC/DC 1000A in specification, and 2000A overload protection
Autoranging
Dual Hall sensor
1.9% basic DCA/ACA accuracy
0.5% basic Hz accuracy
Frequency measurement by clamp-on
Peak hold function
Auto zero key for DCA
Auto power off
Up to 51mm dia. (2”) conductor
Up to 24x60mm busbar
4 feet drop proof
Hand guard designed
Deluxe carrying case
IEC 1010-1 CAT. II 1000V