APPA 30 SERIES CLAMP INSTRUMENTS

SPECIFICATIONS: (All at 23°C±5°C,

80% R.H.)

AC VOLTAGE:

DC VOLTAGE:

AC CURRENT:

APPA 32

Ranges:

Resolution:

Accuracy:

Input Impedance: 10M

//<100pF

Overload Protection: 600Vrms

Conversion Type: Average sensing RMS indicating

Ranges:

Resolution:

APPA 31 APPA 30T APPA 39T APPA33/33R APPA 35N/35R APPA 33 II /33R II APPA 39AC/39AR

400V,600V 400V,600V 600V 400V, 400V

APPA 36 II /36R II APPA 30 /30R APPA 39/39R APPA 39MR

, 600V

0.1V 0.1V 0.1V 0.1V 0.1mV 0.1mV

±(1.2%+5d),40Hz~500Hz ±(1.2%+5d),40Hz~500Hz ±(1.2%+3d),40Hz~500Hz ±(1.2%+5d),40Hz~500Hz ±(1.5%+5d),40Hz~500Hz ±(1.5%+5d),40Hz~500Hz

• • • • •

0.1V

±(1.2%+5d),50Hz~500Hz

• •

33 • 33R True RMS

• • • • • 850V rms

35N • 35R True RMS 33 II • 33R II True RMS 39AC • 39AR True RMS 36 II • 36R II True RMS 30 • 30R True RMS 39 • 39R True RMS True RMS

400V, 1000V 400mV~600V 400mV~600V 400V, 1000V

0.1V 0.1mV

0.1mV 0.1V

Accuracy:

Input Resistance: 10M

Overload Protection: 600V rms

Ranges: 400A

Resolution:

Accuracy:

±(0.7%+5d)

11M

1000V DC

200A,600A

400A,1000A(39AR)/1200A(39AC)

±(0.7%+2d)

400A,600A

±(0.5%+2d) ±(0.7%+2d)

• •

• 1000V DC

40A,300A 400A,1000A 400A, 1000A 100A,600A 40A,300A 100A.1000A 400A,600A

1mV/A 10mV/A,1mV/ A

50~60Hz 45Hz~400Hz

10mV/A,1mV/ A 10mV/A,1mV/ A 0.1A

40Hz~400Hz 40Hz~400Hz 50Hz~60Hz

0.1A

50Hz~60Hz

0.1A

50Hz~60Hz

0.1A 100mA

50Hz~60Hz 50Hz~60Hz

10mA

50Hz~60Hz

0.1A 0.1A

40Hz~400Hz 40Hz~400Hz

±(1.9%+0.5A),0A~350A ±(2%+2A),0A~ 100A ±(1.0%+0.1A),0A~ 40A ±(1.9%+2A), 0A~100A ±(1.9%+5d),0A~400A ±(1.9%+5d) ±(1.9%+5d),200A ±(1.9%+8d), 0A~40A

±(3.2%+1A),350A~400A ±(2%+2A),100A~400A ±(1.0%+1A),40A~200A ±(1.9%7A),100A~400A ±(2.9%+5d),400A~600A

±(1.9%+7d),0A~40A ±(1.0%+5d),0A~4A ±(1.9%+8d),0A~40A ±(1.5%+5d), 0A~600A

±(1.5%+5d),0A~400A ±(1.9%+5d), 40A~400A ±(1.9%+5d),40A~400A ±(1.0%+3d),4A~200A ±(1.9%+7d),40A~400A 40Hz~200Hz

±(3%+2A),400A~600A ±(1.9%+2A),200A~300A ±(2.9%+5A),400A~1000A

400A

±(2.5%+5d),400A~600A

±(2.9%+5d), 400A~1000A(39A)

±(2.9%+5d), 400A~1200A(39A)

±(1.9%+10d),400A~600A ±(3%+3d),200A~300A ±(2.9%r+5d),400A~1000A ±(2.5%r+5d), 600A~1000A

61Hz~400Hz 40HZ~1KHZ

±(2.5%+7d),0A~40A ±(2.0%+7d),0A~4A

±(2.5%+5d),40A~400A ±(1.5%+5d),4A~200A

Conversion Type: Average sensing RMS indicating

FREQUENCY COUNT: Ranges:

Accuracy:

DC CURRENT: Ranges:

Resolution:

Accuracy:

RESISTANCE: Ranges:

Load Impedance:

Position Error:

Type of Sensing :

Resolution:

Accuracy:

Overload Protection:

CONTINUITY TEST: Threshold: < 200 Ω approximate

Indicator: 2KHz tone buzzer

AC and DC

Output Voltage: AC/DC,10mV/A in 100A, 1mV/A in 1000A

Current transformer sensing

Hall effect sensing for AC and DC

100A,600A 40A,300A 100A,1000A

10mV/A,1mV/A 10mV/A,1mV/A 10mV/A,1mV/A

±(2%+2A),0A~100A ±(1.0%+0.1A),0A~40A ±(2.9%+2A),0A~100A

±(2%+2A),100A~400A ±(1.0%+1A),40A~200A ±1.9%+7A),100A~400A

±(3%+2A),400A~600A ±(1.9%+2A),200A~300A ±(2.9%+5A),400A~600A

±(2.5%+10d),400A~600A ±(5%+5d),200A~300A

33 • 33R True RMS 35N • 35R True RMS 33 II • 33R II True RMS 39AC • 39AR True RMS 36 II • 36R II True RMS 30 • 30R True RMS 39 • 39R True RMS True RMS

20Hz~10KHz 20Hz~10KHz

±(0.5%+3d) ±(0.5%+3d)

4K

1

, 40K

±(2% rdg + 9d)

600V rms

• <100 Ω approximate <50 Ω approximate <100 Ω approximate

• • • •

100K Ω min 100K Ω min

±1%rdg ±1%rdg ±1%rdg

AC 1mV per 1A

AC/DC, 10mV/A in 100A,1mV/A in 600AAC/DC, 10mV/A in 40A,1mV/A in 300A

• • •

4K

, 40K

1

1

1

±(1.9% rdg + 8d) ±(1.5% rdg + 2d)

600V rms 600V rms

2000

4K

, 40K

±(2% + 9d)

600V rms

• •

400A,600A 40A,300A 400A,1000A 400A,1000A

100mA 10mA 0.1A 0.1A

±(1.5%+10d),0A~40A ±(1.0%+2d),0A~200A ±(2.9%+8d),0A~100A ±(1.0%+3d), 0A~600A

±(1.5%+7d),40A~400A ±(2.0%+2d),200A~300A ±(1.9%+5d),100A~400A ±(1.9%+5d), 600A~1000A

±(1.9%+10d),400A~600A

400

~40M

400

~40M

±(2.9%+5d),400A~1000A

4K

, 40K

0.1

0.1

±(1.2%+6d),0

~400

±(1.2%+6d),0

~400

±(.0.9%+3d),400

~40K

±(.0.9%+3d),400

~40K

±(1.2%+3d),40K Ω ~4M Ω ±(1.2%+3d),40K Ω ~4M Ω

±(2.5%+5d),4M Ω ~40M Ω ±(2.5%+5d),4M Ω ~40M Ω

1

±(1.0%g+2d)

600Vrms 600Vrms 600V rms

<50 Ω approximate <50 Ω approximate <100 Ω approximate

• • •

±1%rdg

±1%rdg ±1%rdg ±1%rdg

• • •

GENERAL:

Display: LCD digital readout

Measuring Rate: Times per second

Overrange indication:

Low Battery Indicaton:

Auto Power Off: Approx 30 minutes

Operating Temperature: 0°C~50°C, ≤ 80% R.H.

Storage Temperature: -20°C~60°C

Temperature Coefficient: 0.2x(spec. Acc’y)/°C,<18°C or >28°C

Shock Proof: 4 feet drops

Safety: IEC 61010 and designed to meet UL 3111 specifications

Maximum Conductor Size:

Maximum Jaw Opening:

Maximum Busbar Size:

Power Requirement: Single 9V battery (NEDA 1604,IEC 6F22)

Battery Life: In hours (Alkaline battery)

Size: WxLxD in mm

Weight: In grams

Included with Instrument: Safety test leads

Battery(ZnC)

Coiled cable output plugs

User’s manual

Carrying Case

CAT. II 600V

ø29mm

30mm

Red LED

CAT. II 600V

ø34mm

38mm

Red LED

4000 count

4 T/sec

"OL"

Red LED

• •

• •

• • •

• • •

CAT. III 600V CAT. III 1000V CAT. II 600V CAT. II 600V

ø22mm ø51mm ø40mm ø29mm

25mm 53mm 42mm 30mm

250

Installed

20x40mm 24x60mm

45

72x148x36, w/o cable 60x203x27,w/o cable

380

• •

66 66

65.5x185x40,w/o cable 90x232x32,w/o cable

320 420

200

88x215x36

320

User supplied Installed Installed

Installed

Installed Installed Installed

• • • •

• • • •

4000 count

4 T/sec

"OL"

200

77x194x36

250

Installed

2000 count

2.5T/sec

"OL"

• •

0°C~45°C, ≤ 80%RH

• • 10 minutes

• •

• •

• •

• •

CAT. III 600V, CAT. II 1000V CAT. III 600V, CAT. II 1000V CAT. III 600V

ø34mm ø51mm ø35mm

37mm 53mm 45mm

CAT. II 600V CAT. III 1000V CAT. III 600V, CAT. II 1000V

ø22mm

25mm

ø51mm ø51mm

53mm 53mm

24x60mm

• •

200 200

76x200x41 105x268x42

360 420

Installed

Installed

40x15mm

• Alkaline AAA SIZE1.5Vx2

150 50

24x60mm 24x60mm

• •

40 40

82x208x41 66x192x27

360 205

106x240x40 100x265x42

420 420

• •

Installed

• •

Installed Installed (Installed)Alkaline

4000 count

4 T/sec

"OL"

4000 count

2 T/sec

"OL"

4000 count

2 T/sec

"OL"

4000 count 4000 count

2 T/sec 2 T/sec

" OL" " OL"

Specifictions subject to change without notice. Copyright © 2005 APPA Tech., Corp. All rights reserved

APPA 30 Series

The State-of-the-Art Clamp-On Measuring Instruments

Distrubuted by:

APPA TECHNOLOGY CORPORATION

9F, 119-1 Pao-Zong Rd., Shintien, Taipei, 231, TAIWAN

Tel: +886-2-29178820 Fax: +886-2-29170848

E-mail: [email protected]· http://www.appatech.com

ISO 9001 CERTIFIED Advanced Instrument Technology Made Easy

AC CURRENT TRANSDUCER

APPA 31

AC 400A capability

1.9% basic accuracy

Non-intrusive transducing

Up to 29mm diameter conductor

5 feet drop proof

Coiled cable output plugs

Ergonormicly designed jaw and trigger

Hand guard designed

Carrying case included

IEC 1010-1 CAT II 600V

AC/DC CURRENT TRANSDUCER

APPA 32

AC/DC 600A capability

Dual Hall sensor

2.0% basic DCA/ACA accuracy

Non-intrusive transducing

Up to 34mm dia conductor

Up to 20x40mm busbar

DCA zero adjust knob

Power on indicating

Battery low indicator

5 feet drop proof

Coiled cable output plugs

Hand Guard protection

Carrying case included

IEC 1010-1 CAT II 600V

APPA 30T

AC/DC 300A capability

Auto zero key for DCA

Red LED-Low battery indication

GreenLED-Power on indication

Coiled cable output leads

Insulated input jacks

Standard 9V battery

Up to 22mm dia. conductor

4 feet drop proof

Deluxe carrying case

Hand guard designed

IEC 1010-1 CAT. III 600V Safety Standard

APPA 39T

AC/DC 1000A capability

Auto zero key for DCA

Red LED-Low battery indication

GreenLED-Power on indication

Coiled cable output leads

Insulated input jacks

Standard 9V battery

Up to 51mm dia. (2”) conductor

Up to 24x60mm busbar

4 feet drop proof

Deluxe carrying case

Hand guard designed

IEC 1010-1 CAT. III 1000V Safety Standard

AC CURRENT/VOLTAGE/RESISTANCE CLAMP METER

APPA 35N

APPA 35R (True-RMS reading)

4000 count digital display

AC 400A, 600V Capability

Autoranging

1.2% basic ACV accuracy

1.9% basic ACA accuracy

1.9% basic OHM accuracy

Continuity buzzer

Up to 29mm (600MCM) conductor

600V circuit protection

Display hold function

Auto power off

4 feet drop proof

Insulated input jacks

Hand guard protection

Deluxe carrying case

IEC 1010-1 CAT II 600V

APPA 33

II

APPA 33R

II

(True-RMS reading)

2000 count large scale LCD display

AC 600 Amps capability

AC 600 Volts capability

2000 Ohms Resistance range

True RMS ACV/ACA (APPA33R II )

Continuity Beeper

Display Hold

Auto power off

600 Volts circuit protection

Insulated input jacks

Up to 34mm dia. (750MCM) conductor

4 feet drop proof

Protective carrying case

Hand guard designed

CAT. III 600V/CAT. II 1000V Safety Standard

APPA 39AC

APPA 39AR (True-RMS reading)

4000 count digital display

AC 1200A in specification

AC 1000A in specification (39AR)

1500A overload protection

AC 600A, DC 1000V capability

Autoranging

1.2% basic ACV accuracy

1.2% basic DCV accuracy

2% basic OHM accuracy

CONTINUITY beeper

True RMS reading in ACV/ACA

Up to 51mm dia. (2”) conductor

600V circuit protection

Display HOLD function

Auto Power Off

Insulated input jacks

Hand guard designed

Deluxe carrying case

IEC 1010-1 CAT. II 1000V

APPA 33

APPA 33R (True-RMS reading)

4000 count digital display

AC 600A, 600V Capability

Autoranging

1.2% basic ACV accuracy

1.9% basic ACA accuracy

1.9% basic OHM accuracy

Continuity beeper

Up to 40mm dia. (750MCM) conductor

600 Volts circuit protection

Display hold function

Auto power off

4 feet drop proof

Insulated input jacks

Hand guard designed

Deluxe carrying case

IEC 1010-1 CAT II 600V

AC/DC CURRENT CLAMP MULTIMETER

APPA 30

APPA 30R (True-RMS reading)

4000 count digital display

Autoranging

Dual Hall sensor

Nickel-Steel alloy jaw mechanism

AC/DC 300 Amps capability

AC/DC 600 Volts capability

0.5% basic DCV accuracy

1.5% basic ACV accuracy

1.0% basic DCA/ACA accuracy

0.9% basic OHM accuracy

Continuity Beeper

10mA resolution

Auto-Zeroing key for DCA

Data hold function

MAX hold function

Auto power off selectable

600V protection in every range

Up to 22mm dia (350 MCM) conductor

4 feet drop proof

Insulated input jacks

Hand guard designed

Deluxe carring case

IEC 1010-1 CAT II 600V

APPA 39MR (True-RMS reading)

4000 count digital display

AC/DC 1000A in specification, and 2000A overload protection

AC 600V, DC 1000V capability

Autoranging

Dual Hall sensor

Nickel-Steel alloy jaw mechanism

0.7% basic DCV accuracy

1.2% basic ACV accuracy

1.0% basic DCA/ACA accuracy

1.5% basic ACA accuracy

1.0% basic OHM accuracy

0.5% basic Hz accuracy

CONTINUITY beeper

True RMS reading in ACV/ACA

Frequency measurement through input jack or clamp-on

PEAK HOLD function

Auto-Zero key for DCA

Auto Power Off

Up to 51mm dia. (2”) conductor

Up to 24 x 60mm busbar

4 feet drop proof

Insulated input jacks

Hand guard designed

Deluxe carrying case

IEC 1010-1 CAT. II 1000V

APPA 36

II

APPA 36R

II

(True-RMS reading)

4000 count large scale LCD display

Autoranging

Dual Hall Sensor

AC/DC 600 Amps capability

AC/DC 600 Volts capability

40M Ohms Resistance range

True RMS ACV/ACA (APPA36R II )

Continuity Beeper

Display Hold

Maximum Hold

Auto-Zeroing Key for DCA

Auto power off selectable

600Volts Circuit protection

Insulated input jacks

Up to 35mm dia. (750MCM) conductor

Up to 40x15mm busbar

4 feet drop proof

Deluxe carrying case

Hand guard designed

CAT. III 600V Safety Standard

APPA 39

APPA 39R (True-RMS reading)

4000 count digital display

AC/DC 1000A in specification, and 2000A overload protection

Autoranging

Dual Hall sensor

1.9% basic DCA/ACA accuracy

0.5% basic Hz accuracy

Frequency measurement by clamp-on

Peak hold function

Auto zero key for DCA

Auto power off

Up to 51mm dia. (2”) conductor

Up to 24x60mm busbar

4 feet drop proof

Hand guard designed

Deluxe carrying case

IEC 1010-1 CAT. II 1000V