advertisement
▼
Scroll to page 2
of 40
® CommandCall CC2 GSM communication module User & Installations Manual ESPAR Order # PC Setup 2.2 Control SW 3.18 1 Contents 1. Items supplied .................................................... 3 1.1. GSM communications module CommandCall CC2 .................................................... 3 1.2. Accessories .................................................... 4 2. General description .................................................... 5 3. Unit control .................................................... 6 .................................................... 6 3.1.1. Content (format) of SMS message .................................................... 6 3.1.2. Content of Status SMS .................................................... 7 3.1.3. SMS control commands .................................................... 9 3.2. Switching ON the heater by phone call ringing .................................................... 12 3.3. Heater control by phone call with tone dial functions .................................................... 12 3.4. Heater control by ON/OFF push button .................................................... 13 3.5. Heater control by external clock .................................................... 14 3.6. Basic commands memo card .................................................... 14 4. Paging of Alarm states .................................................... 14 5. Supplementary functions .................................................... 16 5.1. System reset .................................................... 16 5.2. Power cut / backup battery .................................................... 16 5.3. Indication of reaching limit temperatures .................................................... 17 3.1. Control via SMS commands 5.4. Thermostat - automatic temperature control within preset temperature intervall .................. 18 5.5. Indication of car battery voltage decrease under preset limit .................................................... 18 5.6. Periodical connectivity test .................................................... 18 5.7. CommandCall status LED indications .................................................... 19 5.8. Optional outputs activation .................................................... 19 5.9. Short circuit .................................................... 19 .................................................... 20 6.1. Password setting .................................................... 23 6.2. VIP Phone numbers .................................................... 23 6.3. SMS settings .................................................... 23 6.4. Variables values range .................................................... 25 6.5. PC Setup values handling .................................................... 25 7. CommandCall USB Programming Adapter .................................................... 26 8. USB to COM port conversion .................................................... 27 9. Installations instructions .................................................... 28 10. Trouble shooting .................................................... 29 11. Wiring diagram .................................................... 30 .................................................... 30 6. CommandCall PC Setup 11.1. Wiring diagram CommandCall with independent heater 11.2. Wiring diagram CommandCall with independent heater and accessories ................. 31 .................................................... 32 12.1. USB to COM port conversion .................................................... 32 12.2. CommandCall PC Setup Installation .................................................... 36 .................................................... 38 12. SW Installations 13. Technical specifications 2 Structure of this manual This manual describes step by step functions of GSM communications module CommandCall CC2, the format of SMS control commands and reports sent to the user, unit controls via phone call with tone dial functions, control via in the vehicle installed ON/OFF push button and gives mounting instructions for unit installation in the vehicle and its connection with the independent heater. Chapters 1 to 5 are important for the user and partially also chapter 6 describing PC Setup parameters setting. Other chapters are dedicated for personel who installs unit in the vehicle and performs start-up procedure. Separate chapter (Chapter 12) is describing SW tools installations necessary for parameter setting before unit installation in the car. This information is not directly relevant to CommandCall CC2 functions, SW tools may be necessary in process of the unit installation in the vehicle. Basic commands overview is helpful tool for the heater control in form of credit card which can be kept by the user all the time ready to use. this sign shows important warnings and remarks in this manual 1. Items supplied 1.1. GSM CommandCall CC2 consists of following parts: 1. Control unit 7. Accessories wire harness 2. Heater wire harness 8. ON/OFF push button 3 3.- 6. Connectors / terminals 9. GSM antenna 10. Temperature sensor Item 1 2 3 4 5 6 7 8 9 10 11 12 11. User manual Item description CommandCall CC2- full set Control unit Heater wire harness Connector body Tyco 4P (terminals) Connector body Tyco 4P (receptacles) Terminal receptacle (Junior-Power-Timer) Terminals (Junior-Power-Timer) Accessories wire harness ON/OFF push button with LED indication GSM antenna Temperature sensor User & installation manual Basic commands memo card 12. Basic commands memo card Qty 1 1 1 2 2 4 4 1 1 1 1 1 1 Ordering code 206300322701 206300329100 206300801201 929505-1 929504-1 927775-3 927892-1 206300801202 206300328400 206300321200 206300324900 N-206300322701-001 N-206300322701-201 1.2. Accessories The CommandCall CC2 functionality may be extended with following parts: 3/4. Blocking relay 1. USB Programming Adapter Item 1 2 3 4 5 2. GSM window antenna Item description CommandCall USB Programming Adapter GSM window antenna Blocking relay 12V / 30A Blocking relay 24V / 20A Relay wire harness 4 5.Relay wire harness Qty 1 1 1 1 1 Ordering code 206300001700 206300321101 2-1393302-2 5-1393302-1 0-0999017-1 2. General description GSM communication module CommandCall CC2 is used for transfer of control commands and reports between the user and the vehicle via SMS of GSM network and via phone calls with tone dial function to control connected device via control signals 300 mA. CommandCall CC2 enables: • control and monitoring of the status of independent heater in vehicle via SMS commands and reports and by phone call with tone dial function • to switch ON the heater (ventilation) by phone call ringing without establishing full connection - this requires no charges from network operator • to switch ON the heater (ventilation) and to switch it OFF by ON/OFF push button with LED indication in the vehicle • to toggle heater / ventilation mode by ON/OFF push button with LED indication in the vehicle • to activate / deactivate external clock (e.g. if control signals of external clock are accepted or not by main control unit) • to measure actual in car temperature and automatic temperature control within temperature intervall • actual temperature readings shown in °C or °F • to measure actual voltage of vehicle battery with indication of its decrease below preset limit value • paging of car alarm and external device alarm status information with possibility to handle alarm states independently or as logicaly related • activation / deactivation of optional outputs (simultaneous activation / deactivation) • voice messages language selection for heater/ventilation control by phone call with tone dial function Integrated part of the CommandCall is built in GSM module (phone) supporting SIM 1,8V and 3V cards of any GSM mobile operator at 850/900/1800/1900 MHz. In the system may be used any post-paid or prepaid SIM card. In the case of using prepaid SIM card it is important to watch SIM card validity (expiration) and keeping necessary credit available on the card to be sure the system is ready to send SMS report to the user when needed. Some mobile operators offer the feature of automatic maintenance of minimal credit. GSM communication module CommandCall CC2 can be used in any type of vehicle due to its voltage auto sensing feature (auto sensing 12 / 24V). CommandCall is not an Alarm, it is GSM communication module used for transfer of commands and reports for independent heater control in the vehicle. Car alarm and external device alarm outpus can be connected to CommandCall CC2 and then alarm signals can be taken in consideration and the user can be informed accordingly. 5 3. Unit control The user communicates with in the car installed unit via sending and receiving SMS, by making phone call with tone dial function or directly by ON/OFF push button in the vehicle. All mentioned ways of control is possible to combine. Control signals of external clock can be override by SMS commands, by phone call commands or by ON/OFF push button operation. It means if heater was switched ON by external clock then SMS command “0” or pressing ON/OFF push button will switch OFF the heater. Format of sent commands is described in the table „Control commands“ (article 3.1.2.). Format of the commands is fixed, the format (text) of SMS reports which CommandCall sends to the user may be set during the unit installation. All parameters except PIN code of SIM card may be changed / set during standard operation by specific SMS command. Control by phone call is done through 2 way communication, when CommandCall CC2 delivers messages to the user via voice messages and accepts user’s commands given by pressing phone buttons during phone call. Communication can be in preset language from 14 languages available (English, German, Slovak, Czech, Swedish, Norsk, Polish, French, Russian, Hungarian, Finish, Danish, Italian and Spanish). 3.1. Control via SMS commands Format of SMS commands has fixed syntax: „password“ „command code“ „command parameter“, while „password“ consist of 4 digits „command code“ consist of one to three digits „command parameter“ is specific for each command and can contain phone number, time information, requested temperature value, ... Commands code with leading zero(s) may be used in short version, e.g. with leading zero(s) omitted. For example the command „003“ can be used in short version as „3“. There is no separator in between the password and command code (space, comma, ...). Between command code and command parameter is used separator “-“ and between each 2 parameters is used comma as separator. User password is factory set to the value 1234. By setting checkbox „Password disable“ in CommandCall PC Setup it is possible to disable using user password in the system and then all SMS commands starts directly with the command code (in such case the password is not used at all). User password is possible to change any time by using SMS command „781“ or by CommandCall PC Setup. Users listed in VIP phone numbers list do not use password in SMS commands even when password is requested from other users. Execution and confirmation of individual command can be delayed depending on actual traffic in used GSM network. 3.1.1. Content of SMS report The content of SMS reports (text of SMS reports) sent to the user is factory preset but it is possible to change it during system installation by using CommandCall PC Setup. Reports texts can be in local language. SMS reports can contain only characters of English alphabet and decimal digits. 6 Every type of SMS report has its own checkbox. If respective checkbox is activated then relevant SMS will be sent to the user. If respective checkbox is not activated then relevant SMS is not sent to the user even in the case all other conditions neccessary for its sending are present. By setting checkboxes No.20 to 23 user can select whether information on remaining heating time, actual in car temperature and car battery voltage will be added to relevant SMS reports. When user sends SMS command with invalid format, invalid password, with invalid command code, with invalid number of parameters or parameters values the system will return SMS report No.16 - “Invalid command”. Note: when VIP user sends SMS command with valid password such command is accepted by the system Group of SMS reports sent by the system to the user which contain besides the text also parameter value has common checkbox No.17 and format of these reports is not possible to modify by the user („fix“ type reports). SMS reports sent by CommandCall to the user can be separated into 2 categories: • reports sent by the system to the user based on specific event: CommandCall CC2 after processing specific event (pressing ON/OFF push button, switching the heater ON or OFF by external clock, signal received from the car alarm, periodical test timeout, ...) sends SMS report relevant to performed activity. SMS reports with “single” checkbox (SMS reports No.: 2, 3, 6, 7, 10 to 13) are sent to the first phone number stored in VIP phone numbers list. SMS reports with “tripple” checkbox (SMS reports No.: 29 to 40) can be sent up to 3 VIP phone numbers (warning type SMS where may be needed to send such message to more phone numbers). • reports sent by the system to the user as an answer to command / request of the user: CommandCall CC2 after receipt of SMS command or user request (switch ON or OFF the heater, setting system parameters, request on actual heater status and in car temperature (status SMS, ...) sends back to the user report relevant to received command or request. Status SMS provides complex information on actual status of the device and it consists of more information fields concatenated into one SMS report. 3.1.2. Content of Status SMS: Field 1: actual satus of the heater/ventilation represented by one of SMS reports 4 - 13 or 41 Field 2: if checkbox No.18 is activated then text „Automatic mode“ will be included in the final message Field 3: if checkbox No.18 is activated then depending on thermostat actual status value „0“ or „1“ will be included in the final message indicating actual thermostat status. Thermostat status table is given below. In the case heater is switched OFF (SMS No.41) then Field 3 is not included in Status SMS. Field 4: if External clock is enabled (system accepts control signals of external clock) then SMS report No.14 will be included in final message Field 5: remaining ON time in format „MMM min.“ (MMM is value of remaining minutes) Field 6: actual in car temperature in format „±ttt.t C“ when °C is selected or „±ttt.t F“ when °F is selected by checkbox No.19. 7 Field 7: actual voltage of vehicle battery in format „vv.v V“ (vv.v is car battery voltage value) In Status SMS containing SMS No.4, 5, 7 - 9, 11 - 13 fields No.1, 5, 6 and 7 must be always present regardless respective checkboxes setting. In Status SMS containing SMS No.6, 10 or 41 fields 1, 6 and 7 must be always present regardless respective checkboxes setting. Individual fields of the Status SMS are separated by comma and next field starts on new line. Thermostat actual status depends on actual temperature and its evaluation in relation to preset temperature levels UST1 and UST2. Following states can appear: Actual temp. vs. temp. intervall Actual thermostat status heating ventilation situation when SMS No.36 is sent OFF (0) ON (1) situation when SMS No.37 is sent ON (1) OFF (0) situation when SMS No.38 is sent OFF (0) ON (1) situation when SMS No.39 is sent ON (1) OFF (0) 36 38 UST1 UST2 39 37 Sample of final message for SMS No.6, with activated checkbox No.18, actual temp is below UST2 (SMS 38 was sent), external clock enabled: Heater ON by clock, Automatic mode, 1, External clock enabled, +14.5 C, 12.7 V Sample of final message for SMS No.11, with deactivated checkbox No.18, actual temp is below UST2, external clock disabled: Ventilation ON by button, 23 min., +14.5 C, 12.7 V Sample of final message for SMS No.41, with activated checkbox No.18, actual temp is below UST2, external clock disabled: Eberspaecher OFF, Automatic mode, +14.5 C, 12.7 V CommandCall CC2 answers to the user request by sending SMS report to the phone number from which original request / command was sent to CommandCall. Sending out of each respective SMS report is based on condition that relevant checkbox is activated during system installation by using CommandCall PC Setup. The change of checkbox activation settings is possible any time by using SMS commands „281“, “481” or “581”. It is important to activate only those checkboxes which reports are necessary for proper user information and correct operation of the unit (keep in mind that sending SMS reports is charged according to used prepaid or post-paid program of respective GSM network operator). 8 3.1.3. SMS control commands Code Check box SMS 1 1 Switch ON the heater for preset time SMS command in form xxxx001 (xxxx is user password) Heater ON by SMS, MMM min., ± ttt.tC, vv.vV will switch ON the heater for preset time and SMS No.4 in range 1 to 120 minutes or unlimitted is sent. When preset time expires system will switch OFF the heater. 4 4 If preset heating time HTTP=999 then heater is switch Heater ON unlimitted, ± ttt.tC, vv.vV ON for unlimitted time and SMS No.12 is sent. Switch ON ventilation for preset time SMS command in form xxxx002 (xxxx is user password) Ventilation ON by SMS, MMM min., ± ttt.tC, vv.vV will switch ON the ventilation for preset time and SMS in range 1 to 120 minutes or No.8 is sent. When preset time expires system will unlimitted switch OFF ventilation. 12 12 8 8 If preset heating time HTTP=999 then ventilation is Ventilation ON unlimitted, ± ttt.tC, vv.vV switch ON for unlimitted time and SMS No.13 is sent. User request on actual status (Status SMS command in form xxxx003 (xxxx is user password) see Status SMS description SMS) sends Status SMS describing actual state of the device. Status SMS consist of several information fields. SMS command in form xxxx004 (xxxx is user password) External clock activated Activate external clock enables controll of the heater/ventilation by external clock, activates checkbox No.27 and sends SMS No.14. 13 13 14 14 15 15 Command Description 0 Switch OFF the heater / ventilation SMS command in form xxxx000 (xxxx is user password) Eberspaecher OFF by SMS, ± ttt.tC, vv.vV will switch OFF the heater (ventilation) and SMS report No.1 is sent 1 2 3 4 5 Deactivate external clock 010 Switch ON the heater/ventilation for 10 minutes. Selection of heating or ventilation is according to the last used staus. SMS command in form xxxx005 (xxxx is user password) disables controll of the heater/ventilation by external clock, deactivates checkbox No.27 and sends SMS No.15. SMS command in form xxxx010 (xxxx is user password) will switch ON the heater or ventilation, sends SMS No. 4 or 8 (depending on last used status heating/ventilation). 10 minutes later system will switch heater/ventilation OFF Text of SMS report External clock deactivated Heater ON by SMS, 10 min., ± ttt.tC, vv.vV or Ventilation ON by SMS, 10 min., ± ttt.tC, vv.vV. NOTE: remaining time must be shown regardless checkbox 30 setting. 4 or 8 4 or 8 011 Switch ON the heater/ventilation for 11 minutes. Selection of heating or ventilation is according to the last used staus. SMS command in form xxxx011 (xxxx is user password) will switch ON the heater or ventilation, sends SMS No. 4 or 8 (depending on last used status heating/ventilation). 11 minutes later system will switch heater/ventilation OFF. Heater ON by SMS, 11 min., ± ttt.tC, vv.vV or Ventilation ON by SMS, 11 min., ± ttt.tC, vv.vV. NOTE: remaining time must be shown regardless checkbox 30 setting. 4 or 8 4 or 8 12-1 Switch ON the heat./vent.for 12 to 19 119 min. ... ... 4 or 8 4 or 8 9 Code Description Text of SMS report Check box 120 Switch ON the heater/ventilation for 120 minutes SMS command in form xxxx120 (xxxx is user password) will switch ON the heater or ventilation, sends SMS No. 4 or 8 (depending on last used status heating/ventilation). 120 minutes later system will switch heater/ventilation OFF. Heater ON by SMS, 120 min., ± ttt.tC, vv.vV or Ventilation ON by SMS, 120 min., ± ttt.tC, vv.vV. NOTE: remaining time must be shown regardless checkbox 30 setting. 4 or 8 4 or 8 280 SMS command in form xxxx280-PP (xxxx is user 280-PP=yyy...yyy (yyyyyy is value/actual setting of requested phone password) will return SMS with actual value/setting of requested PP (Following PP can be accepted: P1 to number / checkbox / parameter) P6, S1 to S28, T1 to T12, HTP, AP, APH, CBV, VS, PTD, PTH, PTM, UST, TS, UST1, UST2, TS1, LANG) Command Request for one of Phone number / checkbox setting / parameter value - fix 17 fix - fix SMS command in form xxxx381-P1=TTT...T,P2= 381 OK TTT...T,P3=TTT...T,P4=TTT...T,P5=TTT...T,P6=TTT...T (xxxx is user password) will set all VIP phone numbers to specified values will return SMS with sequence of 28 characters „0“ or „1“, 480-NNNN.......NNNNN where each “0” means respective checkbox is deactivated and „1“ means respective checkbox is activated. The position in the sequence gives number of the respective checkbox (1 - 28) 17 fix - fix SMS command in form xxxx481-NNN...N (xxxx is user 481 OK password) will set all checkboxes as specified by respective N. Each N can contain „0“ for deactivating and „1“ for activating of respective checkbox. The serial number of respective checkbox is given by position in sequence (1-28) SMS command in form xxxx580 (xxxx is user password) 580-T1=PPP,T2=PPP,...,T12=PPP will return SMS with information on settings of all "triple" checkboxes (T1 to T12). Every of these triple checkboxes has 3 fields for giving golden phone number from the list where specific SMS should be sent. 17 fix - fix 281 Setting of one phone number / checkbox / parameter SMS command in form xxxx281-PP=yyy...yyy (xxxx is 281 OK user password) will set PP to new value/setting yyy...yyy (accepted PP can be: P1 to P6, S1 to S28, T1 to T12, HTP, AP, APH, CBV, VS, PTD, PTH, PTM, UST, TS, UST1, UST2, TS1, LANG) 380 SMS command in form xxxx380 (xxxx is user password) 380-P1=TTT...T,P2=TTT...T,P3=TTT...T, will return SMS containing all VIP phone numbers P4=TTT...T,P5=TTT...T,P6=TTT...T Request for all VIP phone numbers 381 Setting all VIP phone numbers 480 Request on actual setting of all "single" checkboxes 481 Setting all "single" checkboxes 580 Request on actual setting of all "triple" checkboxes SMS 10 Code Command Description Text of SMS report 581 Setting all "triple" checkboxes SMS command in form xxxx581-T1=PPP,T2=PPP, ...,T12=PPP (xxxx is user password) will set all checkboxes as specified by respective P. Each P represent position of stored golden phone number (accepted values 0 to 6). 581 OK 680 Request on actual values of all parameters SMS command in form xxxx680 (xxxx is user password) 680-HTP=mmm,AP=s.s,APH=sss,CBV=vv.v,VS will return SMS with actual values of all parameters =sss,PTD=dd,PTH=hh,PTM=mm,UST=±ttt.t,TS=sss, UST1=±ttt.t,UST2=±ttt.t,TS1=sss,LANG=ll 681 Setting all parameters SMS command in form xxxx681-HTP=mmm,AP=s.s, 681 OK APH=sss,CBV=vv.v,VS=sss,PTD=dd,PTH=hh,PTM=m m,UST=±ttt.t,TS=sss,UST1=±ttt.t,UST2=±ttt.t,TS1=sss, LANG=ll (xxxx is user password) will set all checkboxes as specified. SMS command in form xxxx781-NNNN (xxxx is user Password change OK password) will change user password from xxxx to NNNN Command in form xxxx781 (xxxx is user password) will Password disable disable using of user password. 781 User password change Command in form 781-NNNN will restore using of user password and will set its new value to NNNN. Password change OK Check box SMS 17 fix - fix 17 fix 17 44 17 45 17 44 Note: • VIP phone numbers do not use the password even when regular users has to use it. However, if VIP user sends SMS command with valid password such command is accepted • F is used as temperature unit (°Fahrenheit) instea d of C (°Celsius) when checkbox No.19 is activated • accepted values range is shown in hapter 6 of this manual • SMS report format shown in column “Text of SMS report“ is for indication only, in mobile phone are the fields with values placed on new line for easier readings Sample of setting checkboxes by SMS command 481: SMS command in format xxxx481-1001111101010100000001010000 sets single checkboxes No.. 1, 4, 5, 6, 7, 8, 10, 12 14, 22, 24 to activated status („1“) and checkboxes No. 2, 3, 9, 11, 13, 15, 16, 17, 18, 19, 20, 21, 23, 25, 26, 27, 28 to deactivated status (“0”), xxxx is user password. Note: For reseting checkboxes to new values by SMS command 481 is suggested to read actual seting by command xxxx480 (xxxx is user password) and then to edit received SMS report to command 481 format. 11 3.2. Switching ON the heater by phone call ringing This function is available only for calls made from phone numbers listed among VIP phone numbers and when checkbox No.25 - “Enable heater/ventilation ON by phone call ringing” is activated. Incoming phone call will be handled as follows: a. phone call is possible to cancel by user within 10 seconds from it start (before the third ring) and in such case nothing happens. Incoming phone call can is not indicated in the vehicle and pressing ON/OFF push button has no influence on phone call handling. b. after 10 seconds is phone call rejected by the system and it is accepted as command to switch ON heater / ventilation for time period set by HTP value. If checkbox No.5 (9) is activated then SMS report No.5 - “Heater ON by phone call ringing” or SMS No.9 - “Ventilation ON by phone call ringing” is sent to the caller phone. c. if heater or ventilation is already ON when the phone call is ringing then incoming phone call is accepted and handled in mode of phone call with tone dial functions. d. every phone call made from the phone number which is not listed among VIP phone numbers is accepted and handled in mode of phone call with tone dial functions regardles heater (ventilation) is ON or OFF. e. if checkbox No.25 is not activated then every phone call is accepted and handled in mode of phone call with tone dial functions regardles it is made by VIP phone number or not and regardles heater (ventilation) is ON or OFF. 3.3. Heater control by phone call with tone dial functions Control by phone call with tone dial functions is made as 2 way communication where CommandCall CC2 plays voice messages to user and accepts user commands by pressing phone buttons during phone call. This method is used to control only basic functions of the unit: Button Function 0 switch OFF heater / ventilation 1 switch ON heater for preset time (duration) HTP minutes 2 switch ON ventilation for preset time (duration) HTP minutes 3 request for actual status of the unit 4 activate external clock (control signals of external clock will be taken into consideartion) 5 deactivate external clock (control signals of external clock are not taken into consideartion) After phone call is established system requires password from unknown phone numbers (not listed among VIP phone numbers). When valid password is entered system announces actual status of the unit (Heater / ventilation ON or OFF) and requests user to input command. User gives valid command by pressing some of phone buttons 0 to 5. System acknowledges accepting of the command by voice message and requests next command. User has 5 seconds time limit to input command (to press button). In the case user will press no button within time limit sytem requests command input again. If user input no command even after the third request phone call is terminated. 12 Pressing any other button than 0, 1 to 5 system evaluates as invalid command and requests to input command again. If user inputs 3 times invalid command in the sequence then phone call is terminated. In the case checkbox No.24 is activated and during phone call was given command „3“ then immediately after phone call termination Status SMS will be sent to the user (caller phone). Communication (playing voice messages) can be selected in one from 14 languages. Language selection can be done by SMS command 281 or 681 (see article 3.1.2. SMS Control commands) 3.4. Heater control by ON/OFF push button Heater/ventilation is possible to control by ON/OFF push button installed in the vehicle: Function Switch heater ON Description Short pressing of the push button (max. 1 second). The heater will be ON depending on parameter HTP preset time in the range of 1 to 120 minutes or unlimited in the case HTP=999. If checkbox No.7 is activated then SMS No.7 is sent. Switch ventilation ON The same as for heating but LED will flash Heater / ventilation mode change Pressing of the push button for 5 seconds will toggle heater/ventilation mode. After 5 seconds LED will start to indicate actual mode - when entering heater mode LED will lit 5 seconds while when entering ventilation mode LED will quickly flash for 5 seconds. When this indication starts release the push button to accept mode change. Note: heater/ventilation mode change perform only when heater/ventilation is OFF, otherwise LED indication can not be seen correctly. Pressing of the push button for at least 40 seconds will reset the system. System RESET will restart CommandCall control unit, will restart GSM module, resets outputs overload protection circuits and clears internal counters. System RESET will not change checkboxes settings or preset values (UST, TS, ..., timer preset). Status indications / SMS After button release LED will lit ON indicating heater status „ON“. Heater ON by switch, MMM min., ±ttt.t C, vv.v V After button release LED will flash indicating ventilation status „ON“. If checkbox No.11 is activated then SMS No.11 is sent. Ventilation ON by switch, MMM min., ±ttt.t C, vv.v V Switch Short pressing of the push button (max. 1 second). After button release LED will heater OFF switch OFF indicating status „OFF“ If checkbox No.3 is activated then SMS No.3 is sent. “Eberspaecher OFF by switch, system RESET Backup battery cut OFF ±ttt.t C, vv.v V After 5 seconds LED will start indication of mode change. Indication of entered mode lasts 5 seconds, during this period release the button to accept mode change. Then system indicates new mode by 5 seconds lit for heater mode or 5 seconds flashing for ventilation mode. After 5 seconds LED will flash 5 times - please keep push button pressed. When the time 40 seconds is reached LED will flash 4 times release the push button now. After release of push button LED will lit 2 sec. to indicate RESET Press and hold the push button for at least 20 seconds All LEDs will switch OFF when the power is OFF, this will cut OFF CommandCall backup battery Note: Status will be changed after button is released (system reacts on signal „fall down edge“). 13 3.5. Heater control by external clock When checkbox No.27 is activated then signals of external clock will be accepted, when is deactivated then signals of external clock will be ignored by the system. Device will be switched ON by external clock signal in actual mode heater/ventilation and stays ON according to external clock settings. If checkbox No.6 (9) is activated then after switching ON by external clock SMS No.6 - Heater ON by clock, ±ttt.t C, vv.v V or SMS No.9 - Ventilation ON by clock, ±ttt.tC, vv.vV is sent to the first VIP phone number stored in control unit. In the case heater or ventilation is ON and checkbox No.27 is activated then falling edge of the signal of external clock will switch the heater OFF (regardless how it was switched ON) and SMS No.2 Eberspaecher OFF by clock, ±ttt.t C, vv.v V is sent to the first VIP phone number. If checkbox No.27 is not activated then falling edge of the signal of external clock has no effect on heater/ventilation operation. Description of external clock is included with External clock and is not subject of this manual. Note for all methods of control of heater/ventilation: if heater preset time (HTP) is set to 999 then heater/ventilation is switched ON for unlimitted period of time and SMS No.12 - Heater ON unlimitted, ±ttt.t C, vv.v V or SMS No.13 - Ventilation ON unlimitted, ±ttt.t C, vv.v V is sent to the user. 3.6. Basic commands memo card As a help for the user to control independent heater by SMS commands this card shows an overview of mostly used commands for the heater control in form of credit card, which can be permanently present in user’s wallet. front side reverse side 4. Paging of alarm states Vehicle Alarm After car alarm defence area was triggered CommandCall sends SMS report No.29 - Alarm trigger to the phone number stored as the first one in tripple checkbox No. 29 (T1) and than makes a phone call to this number. User can press “Call terminate” button on his mobile phone to terminate phone call, otherwise system will cancel phone call automatically after approximately 15 seconds. In the case in tripple checkbox No. 29 (T1) are stored more phone numbers then system makes the same procedure with the second and then with the third phone number (according to position of the number in VIP phone numbers list). 14 For alarm trigger signal it is possible to set 2 parameters: • AP - minimal signal pulse length which will be accepted by system • APH - time intervall in which system holds alarm signal ON after receiving valid alarm trigger pulse Note to APH setting - APH value should be set long enough to cover the whole alarm cycle, if shorter, then message Alarm trigger may be sent to user several times. Alarm triggers handling, checkbox No.29 (T1) is activated AP AP APH AP AP AP APH Alarm trigger no activity (pulse length < AP) SMS + call no activity (within APH) no activity (within APH) SMS + call APH AP Alarm trigger SMS + call no more activity, only rising edge of alarm trigger signal can start activity of alarm signal handling External device alarm After triggering alarm of external device installed in the vehicle CommandCall CC2 sends SMS report No.30 - External device trigger to the phone number stored as the first one in tripple checkbox No. 30 (T2) and than makes a phone call to this number. User can press “Call terminate” button on his mobile phone to terminate phone call, otherwise system will cancel phone call automatically after approximately 15 seconds. In the case in tripple checkbox No. 30 (T2) are stored more phone numbers then system makes the same procedure with the second and then with the third phone number (according to position of the number in VIP phone numbers list). Depending on checkbox No.28 setting alarm signals „Alarm trigger“ and „External device trigger” handled either as fully independent functions or as logicaly tight together. When checkbox No.28 is activated then message „External device trigger“ can be sent to the user only in the case vehicle alarm is triggered. This is suitable especially in the case when ACC is connected on External device alarm input. In this situation ACC report (ext.device trigger) is sent to the user only in the case vehicle alarm is triggered. If vehicle alarm is disarmed (deactivated) in normal way switching ACC ON will not be indicated to the user. When alarms are handled logicaly tight together every valid pulse of ACC (ext.device trigger) will be processed (even repeated ACC ON (ext.device trigger) within APH period of vehicle alarm trigger. 15 Logicaly tight handling of car alarmu and ext.device alarm, checkboxes No.28, 29 and 30 are activated APH AP AP AP AP AP car alarm trigger ext.device trigger SMS + call Alarm trigger SMS + call Ext.device trigger no activity SMS + call (pulse< AP) Ext.device trigger no activity (car alarm is not triggered) In the case checkbox No.28 is deactivated SMS report „External device trigger“ will be sent to user every time valid signal of Ext.device trigger is recorded regardless + and - vehicle alarm triggers. For external device trigger signal are used the same AP and APH parameters values. In specific conditions some notification phone call during vehicle alarm or ext.device alarm trigger may be omitted if they should be processed in short period of time. 5. Supplementary functions 5.1. System Reset Pressing the ON/OFF push button and keeping it pressed for 40 seconds will lit LED for 2 seconds and system will RESET. (LED will flash 5 times after push button is pressed for 5 seconds - please ignore this flashing and keep push button pressed. When 40 seconds time is reached LED will flash 4 times - then release the push button). System RESET will restart CommandCall control unit, will restart GSM module and will clear internal counters. Reset will clear also counter of elapsed time for periodical connectivity test, so if „Periodical connectivity test“ is activated, the time for sending relevant SMS report starts from zero again. RESET will not change checkboxes settings or parameters values (UST, TS, HTP, ...). 5.2. Power cut / Back up battery In any operation state of the heater when the power is OFF for at least 5 seconds system sends SMS report No.31 - Power cut to the phone number stored as the first one in tripple checkbox No. 31 (T3) and than makes a phone call to this number. User can press “Call terminate” button on his mobile phone to terminate phone call, otherwise system will cancel phone call automatically after approximately 15 seconds. In the case in tripple checkbox No. 31 (T3) are stored more phone numbers then system makes the same procedure with the second and then with the third phone number (according to position of the number in VIP phone numbers list). Back up battery is cut off automatically after sending SMS reports Power cut to designated phone numbers (sending SMS reports is enabled by backup battery) and whole system is off. After that system will cut off backup battery and switch off the whole system. Backup battery 16 keeps system operation for limitted period of time after disconnecting vehicle battery to enable sending emergency reports to the user. After disconnecting power supply it is possible to disconnect backup battery immediately, press and keep pressed ON/OFF push button for 20 seconds. LED will flash twice after elapsing 20 second time and then release push button. 5.3. Indication of reaching limit temperatures CommandCall enables to measure actual in car temperature and to compare it with 3 stored temperature limit values UST, UST1 and UST2. UST is processed in the system as independent limit temperature value. System monitors actual temperature, reaching limit value UST and the direction of temperature change. If the limit value UST is exceeded and the temperature is stable „behind“ the limit value for time period longer then parameter value TS, system will send to maximum 3 phone numbers listed in tripple checkbox No. 34 or 35 respective SMS report No. 34 or 35 - depending on situation explained in the chart: The values UST1 and UST2 are in the system handled as temperature interval. System monitors actual temperature, entering and leaving interval limits and the direction of temperature changes (temperature increase or decrease). If the limit value is exceeded and the temperature is stable „behind“ the limit value for time period longer than parameter value TS1 system will send to to maximum 3 phone numbers listed in tripple checkboxes No. 36 to 39 respective SMS report No. 36, 37, 38 or 39 - depending on situation explained in the chart: 17 5.4. Thermostat - automatic temperature control within preset temperature intervall CommandCall offers automatic temperature control within preset temperature intervall in the case device is switched ON (device switched ON by any method in heating or ventilation mode). By activating checkbox No.18 thermostat function is enabled. Tempreature intervall limits UST1 and UST2 must be set as well as TS1 value. In heating mode: when temperature decreases below UST2 for longer time as TS1 value then heating is switched ON. Indication LED in ON/OFF push button will lit and actual thermostat status is set to "1". This is till actual temperature cross over UST1 for longer time as TS1 value. In this moment thermostat will temporarily switch OFF heating, indication LED will flash slowly (in cycle: 2 seconds ON and 2 seconds OFF) and thermostat status is changed to "0". Temperature starts slowly decrease and when it decrease below UST2 for longer time as TS1 value the whole cycle will be repeated again. This cycle is repeated while device is switched ON. In ventilation mode: when temperature decreases below UST2 for longer time as TS1 value then ventilation is temporarily switched OFF. Indication LED in ON/OFF push button will flash quickly (in cycle: 2 seconds flashing and 2 seconds OFF) and actual thermostat status is set to "0". This is till actual temperature cross over UST1 for longer time as TS1 value. In this moment thermostat will switch ON ventilation, indication LED will flash quickly and thermostat status is changed to "1". Temperature starts slowly decrease and when it decrease below UST2 for longer time as TS1 value the whole cycle will be repeated again. This cycle is repeated while device is switched ON. LED indication of heating / ventilation during active thermostat control termostatom Heater ON + checkbox No.18 OFF or Heater ON + checkbox No.18 ON + thermostat ON Heater ON + checkbox No.18 ON + thermostat OFF Ventilation ON +checkbox No.18 OFF or Ventilation ON+checkbox No.18 ON + thermostat ON OFF Ventilation ON + checkbox No.18 ON + thermostat OFF + 5.5. Indication of car battery voltage decrease under preset limit Activation of checkbox No.32 (T4) enables measurement of car battery voltage and its comparison to limit level CBV stored in the system. When battery voltage decreases below CBV value and stays below longer time than VOST value system sends SMS No.32 to maximum 3 VIP phone numbers based on tripple checkbox No.32 setting. 5.6. Periodical connectivity test Functionality „Periodical connectivity test“ enables to set up automated process of sending SMS report to maximum 3 VIP phone numbers in preset time intervals which shows operability of CommandCall (for example system will send SMS report No.33 - Periodical connectivity test OK every 15 days). The user has 18 possibility to recognize that something wrong happened to CommandCall if he/she does not receive SMS report in expected time. It can be caused by system malfunction or just by missing credit for sending SMS reports. For activating this feature tripple checkbox No.33 must contain reference to at least one VIP phone number and desired time interval for sending SMS report must be set by combination of 3 values - number of days, hours and minutes. These values can be freely combined in allowed ranges, for example SMS report sending can be repeated every 5 days and 14 hours and 23 minutes (of course it is necessary to set up meaningful time period). Note: System RESET will clear the counter of elapsed time from last SMS report sent to the user. 5.7. CommandCall status LED indications CommandCall control unit is equipped with 2 LED indicating actual operation status of the unit. Meaning of indication status is described in following table: Red LED Green LED Status of control unit flashes (2 sec. interval) flashes (2 sec. interval) standard operation, everything OK flashes (2 sec. interval) flashes (1 sec. interval) GSM module tries to register to the GSM network quickly flashes OFF Power voltage too low for normal operation OFF OFF no power After Power cut the red LED is still ON and CommandCall sends warning message to maximum 3 phone numbers SMS report No.31 - Power cut as it is described in paragraph 5.2. After executing the procedure described in paragraph 5.2. system will cut OFF built in backup battery and will switch OFF whole CommandCall CC2). 5.8. Optional outputs activation Activation of checkbox No.26 will simultaneously activate optional outputs +300mA and -300 mA. Deactivation of checkbox No.26 will simultaneously deactivate these outputs. These outputs may be used to control optional accessories. 5.9. Short circuit If short circuit occurs on the 300mA outputs of the CommandCall system sends SMS No.40 - Short circuit to the phone number stored as the first one in tripple checkbox No. 40 (T12) and than makes a phone call to this number. User can press “Call terminate” button on his mobile phone to terminate phone call, otherwise system will cancel phone call automatically after approximately 15 seconds. In the case in tripple checkbox No. 40 (T12) are stored more phone numbers then system makes the same procedure with the second and then with the third phone number (according to position of the number in VIP phone numbers list). After short circuit disappears the system will recover automatically and restores standard operation. In the case the system will not start normal operation within 10 minutes, RESET the system, please (follow instruction 5.1.). 19 6. CommandCall PC Setup Before using CommandCall PC Setup it is necessary to install CommandCall PC Setup programme on your PC. Installation procedure of CommandCall PC Setup programme is described in details in the Chapter 12. Before programming CommandCall the control unit must be switched OFF from the power and backup battery must by cut OFF too (see 3.4.). When backup battery is switched OFF red LED will switch OFF. During the communication of CommandCall with PC Setup programme CommandCall is powered from USB port of your PC and red LED quickly flashes. During active PC Setup session CommandCall is in service mode and GSM module is not active. It is recommended to take OFF SIM card from the CommandCall control unit before starting its programming by CommandCall PC Setup. Before installing new SIM card into CommandCall control unit set up SIM card PIN to 0000 (default SIM PIN set during HW production). In such case new CommandCall unit can be installed to the vehicle even without using PC Setup. If you plan to use another SIM PIN code you must write this PIN code into CommandCall by PC Setup ! By typing wrong PIN code of SIM card in the CommandCall PC Setup programme the SIM card will be blocked (system tries to register to GSM network repeatedly and will use all 3 allowed attempts to give correct PIN code of the SIM card). It is possible to use SIM card with disabled function of validating PIN code. In such case SIM PIN code stored in CommandCall control unit is ignored. During CommandCall PC Setup installation new icon is created on „Desktop“ of your computer. By left mouse button double click on this icon you can start CommandCall PC Setup programme. CommandCall PC Setup is possible to start also from „START“ menu of your computer through „PROGRAMMS“ submenu. CommandCall PC Setup is stored in „MOLPIR“ folder. Close all applications before using USB Programming Adapter, then insert CommandCall Programming Adapter into any free USB port of your PC and then insert 10 PIN connector into CommandCall control unit. When CommandCall PC Setup starts it should recognize COM port automaticaly, if there is an error please select assigned COM port from the list and then select the language from the list (14 languages are available) and within 30 seconds press “OK” to enter the programme. Note: Manual identification of COM port is described in Chapters 8 and 13 of this manual. 20 Select window of PC Setup for COM port and language selection: After selecting assigned COM port initialization screen of CommandCall PC Setup will be showed for a while: followed by opening of main window of the CommandCall PC Setup: 21 Next are shown parts of PC Setup screens with description of their purpose and the way how to use them: Unit information Version: shows actual version of program stored in CommandCall control unit SIM PIN: insert PIN code of the SIM card which is used in CommandCall 22 6.1. Password settings This part is used for change of password and for enabling/disabling usage of the user password. returns user password value back to factory preset value 1234. Default does not change Default: PIN code of the SIM card inserted into CommandCall control unit. Change password: opens input fields for new password and its reconfirmation Password disable: allows user to send SMS commands without user password when this checkbox is activated, system will execute received command without password validity check. 6.2. Phone numbers for sending SMS This section enables to store VIP phone numbers to be used for sending SMS reports and these users can switch ON heater/ventilation by phone call ringing and for tone dial phone calls without need to enter password. 6.3. SMS settings Every single SMS, where it is reasonable to enable/disable separately option of its sending, has a checkbox for activating SMS sending (when the checkbox is marked ). For some messages (which have tripple check box) it is possible to assign up to 3 VIP phone numbers where the message will be sent. Sent SMS reports can contain characters of English alphabet and numbers, no local characters are supported and the maximum length of a message is 30 characters. SMS reports confirming receipt and executing of the SMS command controlling the heater are sent to the phone number from which was the command sent. SMS commands sent from free SMS gates of internet providers may be in some cases ignored (SMS commands starting with text information are intentionally ignored, because the format of SMS command is fixed and all SMS commands must start with number). Each text field of SMS report in CommandCall PC Setup must contain at least one character, otherwise PC Setup will give error message to the user „SMS detail is null“ and the PC Setup settings as showed on the PC Setup screen can not be written to the memory of CommandCall control unit. SMS reports are a kind of a feed back information on heater operation so it is important to enable sending at least SMS reports when heater/ventilation is switched ON. 23 Part of PC Setup screen for setting single check boxes and their respective SMS report: Part of PC Setup screen for setting tripple check boxes and their respective SMS report: For example shown setting of checkbox No.29 (T1) means that Alarm trigger message will be sent to the sixth VIP number, then to the first VIP phone number and then to the third VIP phone number. Shown setting of checkbox No.33 (T5) means that Periodical connectivity test report will not be sent at all. 24 6.4. Variables values setting and allowed range Heater preset time HTP: 1 to 120 minutes; whole positive numbers only; 999 = switch ON unlimited Alarm signal pulse length, alarm status hold ON : AP: 0.1 to 9.9 seconds APH: 1 to 999 seconds; whole positive numbers only Car battery voltage, time constant for voltage change stability: CBV: 5.0 to 40.0 Volts VS: 1 to 999 seconds; whole positive numbers only Periodical connectivity test can accept following values: PTD: 0 to 99 days, only positive numbers are accepted. PTH: 0 to 24 hours, only positive numbers are accepted. PTM: 0 to 60 minutes, only positive numbers are accepted. Temperature limit values, time constant for temperature change stability UST, UST1, UST2: - 40.0 to +125.0 °C (- 40.0 to +257.0 °F when che ck box No. 19 is activated) for UST1 and UST2 must be: UST1 > UST2 TS, TS1: 0 to 999 seconds; positive numbers only Voice messages language LANG: 1 to 14; whole positive numbers only CommandCall CC2 uses internal format of decimal numbers with decimal point and sent SMS reports also contain decimal point as separator of whole and decimal part of the numbers. However, PC Setup accepts both comma and point as decimal part separator (for accepting regional settings of various PC users). 6.5. PC Setup values handling Print: prints out the content of PC Setup screens on 3 separate pages on connected printer Request: reads out the memory of the CommandCall control unit and displays the values on the screen Apply: writes PC setup screen actual values into CommandCall control unit memory 25 Initialize: loads factory default values to PC Setup screen and to CommandCall control unit memory Save ... : writes PC Setup screen actual values into file stored in your PC (system will request user to specify file name and location). By this means it is possible to have stored several standard configurations of parameters and SMS texts or archives of specific installations / customer settings stored during unit installation. Load ...: reads parameters setting from file stored in your PC onto CommandCall PC Setup screen (system will request user to specify file name and location). Just after using „Apply“ function loaded data from the file are written into CommandCall control unit memory. Exit: quits the session of CommandCall PC Setup CommandCall PC Setup will read only firmware version from control unit after the start and will display it in upper left corner of the screen, in section Unit information. To display actual parameter values press „Request“ on bottom task bar of the CommandCall PC Setup screen. To write actual parameters setting from the PC Setup screen into CommandCall control unit memory please press „Apply“ on bottom task bar of the CommandCall PC Setup screen. The communication of your PC with CommandCall control unit is automatically terminated after 5 minutes of „idle“ period. To restore normal activity of the unit exit PC Setup and start it again, please. In such case when system displays error message „Communication failed“ (during „Request“ or „Apply“ function) it is recommended to store unsaved parameter settings into temporary file on your PC by using „Save“ command, then you can restart PC Setup and you can retrieve those parameters setting onto CommandCall PC Setup screen by using „Load“ function to restore data from the temporary file and to continue your job. Initialisation screen of PC Setup requests to enter COM port number even when CommandCall control unit is connected over the USB port of the computer ! 7. CommandCall USB Programming Adapter CommandCall control unit programming is possible with using USB Programming Adapter. USB Programming Adapter is interface device for connecting CommandCall control unit with PC and to use CommandCall PC Setup. In the case your computer does not recognize inserted USB Programming Adapter it is necessary to install USB to COM port converter utility (USB to UART conversion). Close all applications before inserting USB Programming Adapter into USB port of your PC ! LED built in USB Programming Adapter flashes only during active data transfer between CommandCall control unit and PC Setup programme. CommandCall USB Programming Adapter is optional accessory (it is not included in CommandCall kit). 26 8. USB to COM port converter In the case your computer does not recognize inserted USB Programming Adapter it is necessary to install USB to COM port converter utility (USB to UART conversion). USB to COM port converter utility installation procedure is described in Chapter 13 of this manual. Check if your computer recognised inserted USB Programming Adapter: a. insert USB Programming Adapter to any free USB port on your PC, run „Device Manager“ on your PC and check available COM ports by executing sequence of highlighted commands in defined order (first double click on left mouse button on „My Computer“ icon to open pop up window „My Computer“, then click with left mouse button on „View system information“ in section „System Tasks“, then click on „Hardware“, etc.): b. if no one port among available COM ports is designed to USB Programming Adapter - marked as UART Bridge Controller follow instructions given in Chapter 13. 27 9. Installations instructions During in car installation follow this Installation manual instructions as well as instructions given by car manufacturer concerning installation, operation and usage of mobile phone or GSM module in the car. CommandCall control unit install beneath dashboard of the vehicle as low as possible (regarding extreme high temperatures in summer). Fix the control unit properly with connectors pointing down (to avoid on wires condensed water to leak in the control unit) Small rod GSM antenna (included in the kit) or external GSM antenna (on glass stick on type with higher signal gain, optional accessory) must be connected to CommandCall control unit. The external GSM antenna is mounted from interior on the windshield or rear car window. Clean and dry the place where the antenna will be stick on first, tear off protection film from the antenna and stick on the antenna firmly. Install antenna cable to control unit and screw the connector to SMA connector on the control unit. For the cars with metallized glass windows consider using GSM external roof type antenna. GSM signal level always depends on local conditions and GSM network coverage. Take care when installing SIM card in the control unit as the card holder is tiny mechanical part and can be damaged or broken when manipulated wrong way. Before inserting SIM card into control unit of CommandCall CC2 be sure to check: • PIN code on SIM card is the same as PIN code written to control unit by PC Setup (it is not important in the case using of PIN code is disabled on SIM card) • SIM card has no active divert of phone calls or SMS • SIM card has no active „Call waiting“ function Controls installation ON/OFF push button install in the working area of the driver in place, where is no risk of unwanted operation for example by the drivers or passenger knee. Drill 10 mm hole for installation (maximal wall thickness is 2,5 mm). Insert the cable through the hole, lead it to the control unit and connect contact PINs in respective connector according to wiring diagram. Temperature sensor T1 install in proper place (in the level of drivers face) for example onto front chassis column. Lead temperature sensor cable lead to the control unit and connect contact PINs in respective connector according to wiring diagram. Temperature sensor is used for in car temperature measurement. Wire harness for connecting independent heater has 7 wires (permanent power supply, heater and ventilation control signals, external clock signals) terminated with contacts. Wires with terminals insert in included 4 PIN connector bodies according to wiring diagram. Use corresponding wires from the heater (refer to wiring diagram supplied with the heater). All remaining wires must be isolated separately. 28 Accessories wire harness of car alarm and optional outputs consist of 6 wires. Please be informed that PIN No.1 of connector K2 is connected to PIN No.2 of connector K1 inside the control unit. All remaining wires must be isolated separately. Wait approximately 30 seconds after power on CommandCall till GSM module will register to mobile network operator. After successful registration of the unit to the GSM network it is ready to receive SMS commands and to send SMS reports to the user. Actual operation state of the control unit and its GSM module are indicated by red and green LEDs, the indication is described in table at the end of chapter 5. Supplementary functions (5.7). 10. Trouble shooting Actual status Possible reason Measures to be taken system does not respond power failure weak GSM signal check the fuses and all connections check GSM antenna change vehicle position change CommandCall in car installation location use external GSM antenna check the coverage map of your GSM mobile operator check the GSM network blocking at your operator try later check expiration of used SIM card and remaining credit check SIM card insertion clean SIM card contacts replace damaged SIM card at your GSM network operator try later check remaining credit on SIM card delayed operations command is executed, no SMS sent to user short circuit no GSM signal blocking of GSM network GSM network overload SIM card expiration incorrectly inserted SIM card poor contacts of SIM card damaged SIM card GSM network overload no credit on SIM card system ignore received SMS incorrect SMS command format system does not send SMS of periodical test checkbox No.33 is not activated no credit on SIM card temperature sensor is not connected or is damaged system sends string “- - - -“ instead of temperature value remove the short circuit on output(s) and wait approximately 10 minutes, system will recover automatically. If the problem persist, RESET the system. If the problem still persist, contact authorised service centre. system intentionally ignores SMS commands starting with text (SMS sent by the operator - advertisement or service SMS, messages sent from free or paid GSM gates) and answers only to the phone number from which respective SMS was sent. activate checkbox No. 33 check remaining credit on SIM card check connection and functionality of temperature sensor 29 11. Wiring diagram 11.1. Wiring diagram of CommandCall CC2 with independent heater 30 11.2. Wiring diagram CommandCall CC2 with independent heater and accessories 31 12. SW Installations 12.1. USB to COM port conversion Connection of your PC with CommandCall control unit for modification and setting parameters and sent SMS contents (texts) is realised via USB port connection. It is serial communication and it is necessary your PC will „recognize“ inserted CommandCall USB Programming Adapter as serial port. This is executed by operation system functions (Win9x/NT/2000/XP) or by using specific driver (program CP210x_VCP_Win2K_XP_S2K3.exe). Close all applications before using USB Programming Adapter, then insert CommandCall Programming Adapter into any free USB port of your PC and then insert 10 PIN connector into CommandCall control unit. In case your PC does not recognize automatically CommandCall USB Programming Adapter after its inserting into USB port of your PC, follow instructions described for USB port to COM port converter. Program CP210x_VCP_Win2K_XP_S2K3.exe is supplied on Installation CD ROM together with other SW tools of GSM communication module CommandCall. During installation follow instructions given by installer program. When the installation of USB to COM port converter is finished CommandCall USB Programming Adapter is ready for use. Check if your PC „recognized“ USB Programming Adapter by using following procedure: a. insert USB Programming Adapter to any free USB port on your PC, run „Device Manager“ on your PC and check available COM ports by executing sequence of highlighted commands in defined order (first double click on left mouse button on „My Computer“ icon to open pop up window „My Computer“, then click with left mouse button on „View system information“ in section „System Tasks“, then click on „Hardware“, etc.): b. if no one port among available COM ports is designed to USB Programming Adapter - marked as UART Bridge Controller follow instructions given hereunder: c. remove USB Programming Adapter from the PC (before removing USB Programming Adapter it is not necessary to perform activities usual for USB memory devices removal) 32 d. run CP210x_VCP_Win2K_XP_S2K3.exe program from included Installation CD and accept licence agreement: e. accept the location where Windows drivers will be installed and start of the installation: f. accept the location where the program will be installed and accept computer restart: 33 g. accept final Installation step of the CP210x_VCP_Win2K_XP_S2K3.exe program: h. run „Device Manager“ on your PC to check results of USB to COM port converter installations and check designated COM port number: Note: in used example you can see, that on respective computer COM9 is designated to USB Programming Adapter. For each single installation another COM port can be designated to USB Programming Adapter, but if the installation is not changed, CommandCall USB Programming Adapter will be designated to the same COM port even when inserted to another USB on the computer. Designated COM port depends on computer configuration and it is possible to find designated COM port by checking one by one from the list or to find designated COM port directly by following procedure: Designated COM port for USB to COM port converter you can recognize by the text „CP210x USB to UART Bridge Controller“ in name of the respective port in the list of available COM ports followed by the number of COM port. 34 In the case your PC will recognize CommandCall USB Programming Adapter even without Installation of program CP210x_VCP_Win2K_XP_S2K3.exe it is possible the text in name of relevant COM port will be different, but it should be indicated that the port is allocated for USB to COM port converter. In the case COM port designated for USB to UART converter has the number higher than COM9 (for example. COM15) it is suggested to change assignment of free COM ports by this procedure: By selecting one of free COM ports with lower number from the list the COM port number assignment will be changed accordingly. After appropriate port is selected you can finish COM ports assignment by accepting selections. 35 12.2. CommandCall PC Setup Installation Run Setup.exe which is included on Installation CD ROM together with other SW tools of CommandCall GSM communication module. Confirm the start of installation by pressing „OK“: During the Installation follow instructions of installer program: Press the „Next“ button on Welcome screen of CommandCall PC Setup installer program to proceed to Installation folder input. 36 After accepting or specifying location where the program will be installed press „Next“ again to proceed. Press „Close“ to finish CommandCall PC Setup installation (including all necessary installation components). After installation is completed the program CommandCall PC Setup is ready to use. Part of CommandCall PC Setup installation is the programme .NET Framework 2.1. (in the case it was not installed during Windows installation. Programme .NET Framework is part of legal installation of Windows operating system. Programme CommandCall PC Setup can communicate with the user in one of 14 languages. Selection of the language is available immediately after programme start in Select window. 37 13. Technical specifications: Model: CommandCall CC2 DC power (auto sensing) 12 / 24 V DC power range 9 - 35 V Average current draw (GSM online) ≤ 6 mA Working temperature range - 35 to + 80°C Antenna connector M SMA (male) Antenna impedance 50 Ω GSM module parameters (Siemens MC55i) Frequency range 850/900/1800/1900 MHz SIM card power supply 1,8V; 3V Normal working temperature range -20°C up to + 70°C Restricted working temperature range -40°C up to + 70°C Control unit dimensions: 105 x 65 x 27mm (l x d x h); weight 95 gr. CommandCall unit is electronic device and thus can not be disposed as communal waste. Used product dispose at dedicated recycling collection spot. This unit contains plastics and other recyclable materials. This product was tested and approved for use in accordance with relevant EC directives. 38 This product conforms with the type approved by Ministry of Transport, Post and Telecommunication of the Slovak Republic on September 28, 2007 under Approval No. E27*10R-02*1199*00 and EC type-approval No. e27*72/245*2006/96*1011*00. For this product following marks were alloted: Copyright © 2009, MOLPIR s.r.o. All rights reserved - it is prohibited to copy, reprint or to circulate any part of this Manual without prior written consent of the author. Product parameters are subject to change without prior notice. MOLPIR s.r.o., Hrachová 30, 821 05 Bratislava tel: +421 243 191 218, fax: +421 243 191 220 www.molpir.sk, [email protected] 39
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project