Siemens FIREFINDER-XLS is an advanced fire alarm control panel that offers powerful fire detection and notification capabilities for commercial, institutional, and industrial applications. With its intuitive user interface, easy programming, and support for various detection devices, FIREFINDER-XLS provides reliable fire protection and life safety. Here are some of its key features:
- 2500 addressable point capacity, expandable up to 6300 with network expansion modules.
- 6-inch backlit LCD display with large, lighted buttons for clear system status and control.
- Supports intelligent and analog detection circuits for flexible device connectivity.
advertisement
s
Data Sheet
Fire Safety & Security Products
FireFinder
TM
XLS
Advanced Fire Alarm Control Panel
• point-capacity system
Windows ® laptop PC
ARCHITECT AND ENGINEER SPECIFICATIONS
Standard 2500 addressable,
•
Ability to network with other
FireFinder XLS systems
•
Powerful, easy-to-use programming capabilities
•
Fully field programmable, via
•
6" Backlit LCD display
•
User-friendly system interface
•
Touch screen for maintenance operations and function keys
•
Global annunciation and control capability
•
Multi-language display
•
Universal AC power input:
120VAC – 240VAC @ 50 / 60Hz
•
12 amps of system power
(expandable to 48 amps)
•
Numerous Relays: Alarm, Trouble,
Programmable, etc.
•
SureWire TM addressable-loop technology
•
Polarity-insensitive detection circuits
(patented)
•
Useful diagnostic LEDs on all cards
•
Supports FirePrint TM application-specific detection
•
Intelligent / analog detection circuits:
Class A or Class B
•
Supports single-person test, “Walk Test”
•
Seismic certified
•
Modular assembly
•
Supervised remote printer
•
32-character custom messages
•
Thermal strip printer
•
Security-device monitoring
( UL 1076 Listed)
•
Sprinkler Supervision
•
Degrade-mode operation
•
Coded outputs
•
NCCG Graphics support
•
UUKL Listed for smoke control
•
UL 864 9 th Edition Listed & ULC Listed;
FM, CSFM & NYMEA Approved
•
User help screens
•
Multiple command stations
•
Menu-driven operator commands
•
5000-event, history-logging capability with on-line and off-line reports
•
Multiple levels of password protection
•
Automatic environmental compensation for smoke detectors
•
Alarm verification
by device or zone
•
Pre-alarm operation
•
Logic-controlled output functions
•
Time-based-controlled output functions
•
Holiday schedule
•
City tie / leased line
•
200 notification-appliance-circuits
(NACs) capacity
•
Up to 3.0 amps (24VDC) per NAC
•
Built-in strobe synchronization protocol
•
Supports pre-action, deluge and agent releasing
•
Voice evacuation system (optional)
•
NEC 760 power-limited circuits
( UL 864 Compliant)
•
Intelligent interface to building / process management systems
•
Operates as interactive peer with other
XLS or XLSV units in a XNET network
•
Distributed processing
•
Detector Sensitivity Readout / Printout
per NFPA 72
System Overview
FireFinder XLS is a microprocessor-based, advanced life-safety system that has a 6" display and large, lighted buttons; making it the most intuitive fire-alarm user interface in the industry. Through the use of the unique multiprocessor ‘Network’ design – along with the ability to utilize analog and conventional detection devices – FireFinder XLS exemplifies a flexible and highly configurable life-safety system.
Underwriter's Laboratories of Canada also lists the XLS for fire applications under ULC-S527. FireFinder XLS is Factory
Mutual Approved; as well as CSFM and NYMEA Approved for use in those specific locales. In addition to the standard fire applications, FireFinder XLS is UL Listed under the category UUKL for smoke control. FireFinder XLS can be used as a listed Fireman's Smoke Control Station in highrise office buildings, malls and other large structures.
FireFinder XLS is ideally suited for commercial, institutional and industrial fire detection and notification applications. XLS complies with the requirements of NFPA Standard 72, and is listed by
Underwriters Laboratories under their standard UL 864.
FireFinder XLS is UL Listed and FM Approved for
Sinorix
TM
clean-agent systems and pre-action or deluge sprinkler systems, which include foam or water applications. FireFinder XLS operates on the releasing requirements specified in NFPA 13 and 2001.
FireFinder
TM
XLS Overview
6300 s Industry, Inc.
Building Technologies Division
System Overview ─ (continued)
The FireFinder XLS system has been seismic qualified in accordance with:
International Building Code, 2006 Edition
California Building Code, 2007 Edition
ASCE Standard 7, 2005 Edition
OSHPD CAN 2-1708A.5, Rev. 3
ICC-ES AC 156, Effective 1/1/2007
FireFinder XLS is also OSHPD preapproved under:
OSP-0057-10.
FireFinder XLS Components
The basic FireFinder XLS control unit consists of the following sub-assemblies: Person Machine Interface
(Model PM I ); Power Supply (Model PSC-12); Device Loop
Card (Model DLC); Zone Indicating Card (Model ZIC-4A);
Card cage (Model CC-5); I nner Door Blank Single Plate
(Model ID-SP); CAB-1, CAB-2 or CAB-3 enclosures.
Optional modules that can be installed with the XLS
System include: Card Cage (Model CC-2); Network
Interface Card (Model N I C-C); Zone Indicating Card 8 circuits (Models Z I C-8B / Z I C-2C); Control Relay Card
(Model CRC-6); Output Control Module (Model OCM-
16); Switch Control Module (Model SCM-8); LED
Control Module (Model LCM-8); Fan Control Module
(Model FCM-6); Supervised Input Module (Model S I M-16);
Power Supply Extender (Model PSX-12); Remote Network
Interface (Model RN I ); Remote Printer Module (Model
RPM); System Status Display (Model SSD); Multi-Point
Digital Alarm Communicator (Model MDACT); Two-
Module Remote Enclosure (Model REMBOX2); Four-
Module Remote Enclosure (Model REMBOX4).
The XLS panel is compatible with a full line of intelligent initiating devices, highlighted by the FirePrint applicationspecified detectors: Models HFP-11 and HFPT-11. XLS is also compatible with the NCC series of graphics command centers.
Model PM I contains the site-specific program configuration created in the Zeus system software-programming tool. The controller in Model PM I provides all system logic and supervision. Model PM I contains a large, 6" (1/4 VGA) monochrome LCD display, touch screen and LEDs for displaying system status. A sound is made when there is any unacknowledged event from Model PM I . The display is surrounded by keys that are used to control the displayed information and to navigate through these screens. Keys are also provided to obtain and enter "Help" into the menu features of Model PM I .
The FireFinder system is controlled and operated from
Model PM I . The intuitive person machine interface uses large, lighted buttons to prompt users as to the next correct system operation that is available (Acknowledge,
Silence, Unsilence, Audible or Reset).
DLC Device Loop Card
DLC Device Loop Card
The Device Loop Card (Model DLC) is the interface for connection with FireFinder XLS detectors and initiating devices ─ including manual stations, control and input devices. Model DLC plugs into one (1) slot of the CC-2 or CC-
5 card cage. Programming Model DLC is accomplished using the FireFinder XLS Zeus system softwareprogramming tool. Model DLC takes one (1) address on the network, and communicates with two (2) device circuits for a total of 252 detectors and devices. Model
DLC has 12 LEDs for diagnostic purposes, and provides ground-fault detection and zone-isolation circuitry.
PMI Person Machine Interface
PM
I
Person Machine Interface
The Person Machine I nterface (Model PM I ) is the core of the
FireFinder XLS system. Model PM I serves as both operator interface and central microprocessor for the
FireFinder XLS system. From Model PM I , the end user can acknowledge events, control the systemnotification appliance circuits and reset the system.
Detailed information about the nature and location of the events can also be displayed. s Industry, Inc.
Building Technologies Division
ZIC-4A Zone Indicating Card
Z
I
C-4A Zone Indicating Card
The Zone Indicating Card (Model ZIC-4A) provides four (4) fully supervised, programmable output circuits for use on the FireFinder XLS Fire Alarm Control Panel. Model
ZIC-4A supplies four (4) Class B (Style Y) or Class A (Style Z) type output circuits, power limited to 3.0 amps maximum per circuit.
FireFinder XLS Components
─ (cont.’d)
Each circuit can be independently programmed for use with listed audible or visual notification appliances, listed emergency audio speakers, municipal tie boxes, leased lines, or as releasing circuits. Model Z I C-4A plugs into one
(1) slot in the Model CC-5 or Model CC-2 card cage, and has on-board LEDs for system status and troubleshooting.
Indication of power, communication, internal operation, and ground-fault conditions are provided, as well as indication of circuit activation or Trouble conditions.
When Model N I C-C is used for XNET communications,
Model N I C-C provides communication between systems.
The maximum of XNET Model N I C-C cards on a single system (single node) is one (1), for a total of 64 XNET
Model N I C-C cards on a peer-to-peer networked system.
Model N I C-C has diagnostic LEDs that indicate: Card Fail,
CAN Fail, HNET Fail, XNET Fail, Ground Fault, Loop ‘A’ Fail and
Loop ‘B’ Fail. Model N I C-C Card also has LEDs to indicate
Power, Style and Active Networks.
ZIC-8B / ZIC-2C Zone Indicating Cards
Z
I
C-8B / Z
I
C-2C
The Zone I ndicating Card (Model ZIC-8B) provides eight (8) fully supervised, programmable output circuits for use on the FireFinder XLS fire-alarm control panel (FACP). Model
Z I C-8B supplies eight (8) Class B (Style Y) type output circuits, power limited to 2.0 amps maximum per circuit.
Each circuit can be independently programmed for use with listed audible or visual notification appliances, or listed emergency audio speakers. Model Z I C-8B plugs into one (1) slot in the Model CC-5 or Model CC-2 card cage, and has on-board LEDs for system status and troubleshooting.
Model Z I C-2C mounts directly on Model Z I C-8B, and allows each of the Model Z I C-8B output circuits to be used for two-channel voice applications. I ndication of power, communication, internal operation, and ground-fault conditions are provided, as well as indication of circuit activation or trouble conditions.
HL
I
M Line Isolator Module
HL
I
M Line
I solator Module
The loop-isolator module (Model HL I M) provides shortcircuit protection on FireFinder XLS intelligent device circuits (see: Model DLC). When Model HL I M detects a short circuit, Model HL I M is able to isolate the affected segment of the circuit – allowing the remaining devices to continue operation. Model HL I M is self-restoring – automatically reconnecting to circuit segment when the fault is removed. Model HL I M can be wired in either a
Style 4 or Style 6 configuration.
Model HL I M does not occupy a device address on the Model
DLC circuit, and does not require programming. Up to 15
Model HL I M modules may be installed on each Model DLC loop.
NIC-C Network Interface Card
N
I
C-C Network Interface Card
The Network I nterface Card (Model N I C-C) provides HNET or
XNET network communications between enclosures. I n addition to the HNET or XNET communication, Model N I C-C provides CAN network communication within an enclosure or external to the enclosure. HNET or XNET communication can be wired Style 4 or Style 7, but the CAN network can be wired Style 4 only.
When used for HNET communications, Model N I C-C provides communication between enclosures on a single system. s Industry, Inc.
Building Technologies Division
HCP Control Point Module
HCP Control Point Module
Model HCP provides an intelligent control point for the
FireFinder XLS Control Panel. Model HCP can be programmed as an independent, remotely located telephone zone, speaker zone or notification appliance circuit. Model HCP is designed to be used with the
Siemens – Fire Safety Notification-Appliance Circuits product line.
Model HCP communicates through the Model DLC analog loop, and can be wired either Class A (Style Z) or
Class B (Style Y). The 24 VDC power input comes from either the control panel or from any UL Listed powerlimited, auxiliary-power supply.
FireFinder XLS Components
─ (cont.’d)
CRC-6 Controllable Relay Card
CRC-6 Controllable Relay Card
The Controllable Relay Card (Model CRC-6) is used with the FireFinder XLS FACP. Model CRC-6 is designed to provide auxiliary control of building functions, such as: door-holder release, elevator capture, smoke control, lock release, etc. Model CRC-6 plugs into one (1) slot in the
Model CC-5 or Model CC-2 card cage. Model CRC-6 provides six (6), fully programmable relays. Each relay contains one (1) set of SPDT contacts rated at 4 Amps 30
VDC / 120VAC resistive and 3.5 amps 120VAC inductive (0.6
P.F.)
SIM-16 Supervised Input Module
S
I
M-16 Supervised Input Module
The Supervised input Module (Model S I M-16) is a remotely located, general-purpose input module. Model
S I M-16 provides 16 input circuits for remote system monitoring. Each input can be individually programmed as supervised (dry-contact only) or unsupervised (generalpurpose input.) Model S I M-16 has two (2) Form C relays.
The relays and inputs are programmed using the Zeus system software-programming tool.
CC-2 Card Cage-2 Slots CC-5 Card Cage-5 Slots
CC-5 / CC-2 Card Cages
The Models CC-5 / CC-2 card cages provide the physical mounting location and all wiring connection points for all fire-and-voice system options cards for the FireFinder XLS system. Model CC-5 has five (5) slots, while Model CC-2 has two (2) slots.
All cards plugged into the CC-5 / CC-2 card cage communicate with other FireFinder-XLS modules via a common data bus. Connectors are provided on the left and right side of the CC-5 to connect a 60-pin cable for communications with the FireFinder-XLS' operator interface, power supplies and amplifiers modules.
Field wiring to devices and circuits terminates on the
Models CC-5 / CC-2 card cages. All cards designed for use with the Models CC-5 / CC-2 route their field wiring terminations to the ‘top’ of the Model CC-5 / CC-2 card cages. These connections are all power limited. Internal wiring connections distribute 24VDC to cards or high-level audio signals (depending on application used) connect to the ‘bottom’ of the Model CC-5 / CC-2 card cages. These connections are all non-power limited.
All wiring connections to the Model CC-5 / CC-2 card cages are to removable terminal blocks. Terminal blocks are rated for use with wire sized 12AWG to 24AWG. Each connector is numbered to make wiring terminations to the correct position on the terminal block simple in order to reduce potential wiring errors.
CDC-4 Conventional Detector Card
CDC-4 Conventional Detector Card
The Conventional Detector Card (Model CDC-4) is used to monitor Siemens Fire Safety conventional detectors on the FireFinder XLS system. Model CDC-4 can be used in applications where conventional detectors are more suited than addressable detectors, such as hallways or large meeting rooms. Also, Model CDC-4 can be used to upgrade Siemens conventional fire-alarm panels to the FireFinder XLS system without requiring detector replacement. s Industry, Inc.
Building Technologies Division
SCM-8 Switch Control Module
SCM-8 Switch Control Module
The Switch Control Module (Model SCM-8) is a FireFinder
XLS-option module that provides manual control to the
Emergency Voice Evacuation System (EVAC) or manual fire-system control. Each Model SCM-8 module provides eight (8) momentary push-button switches and 16 light-emitting diodes (LEDs) to indicate their status.
Each switch is assigned two (2) LEDs, as well as a label to indicate the switch's programmed usage. The label slides behind a clear protective membrane. One of the
LEDs assigned to each switch is a dual-colored LED, which is used to indicate what type of signal is active.
FireFinder XLS Components
─ (cont.’d)
Each Model SCM-8 switch is fully programmable, and may be used to control speaker circuits and a wide range of general-system functions such as: All Call, All Evac,
Warden's Page, Speaker, etc. Any number of circuits may be grouped and controlled by a single switch. Switch usages and zone groupings are assigned using the Zeus system software-programming software. Model SCM-8 modules are mounted on a hinged panel, as a part of the
FireFinder XLS Command Console enclosure.
PSC-12 Power Supply Charger Module
The Power Supply Charger Module (Model PSC-12) is a high-current power supply that provides the FireFinder
XLS primary-regulated 24VDC power to operate. Model
PSC-12 is rated at 12Amps (Alarm) / 5Amps (Standby), and has a built-in battery charger, capable of charging up to 100
AH batteries. Model PSC-12 is an addressable-intelligent, microprocessor-controlled module that communicates its status to the system-operator interface (PMI). Model PMI is able to query the status of the power supply to obtain information regarding system-charging current, terminalloading information, ground-fault conditions and more.
LCM-8 LED Control Module
LCM-8 LED Control Module
The LED Control Module (Model LCM-8) is a FireFinder
XLS-option module that provides LED annunciation for
FireFinder XLS system activity. Each LCM-8 module contains eight (8) groups of two (2) LEDs – each of which can be assigned to desired outputs using the Zeus system software-programming tool.
Eight (8) LEDs are dual-color capable ( RED or GREEN /
flashing or steady). The remaining LEDs are AMBER
flashing or steady. A space is provided for labeling of LED functions. The label slides behind a clear, protective membrane. Model LCM-8 dimensions are identical to
Model SCM-8, and Model LCM-8 is mounted on the same hinged panel, as a part of the FireFinder XLS Command
Console enclosure.
FCM-6 Fan, Motor, Dampers
FCM-6 Fan, Motor, Dampers Control Module
The Fan, Motor, Dampers Control Module (Model FCM-6) is a
FireFinder XLS command-console option module that provides manual control of building HVAC system fans, motors, and dampers. Each Model FCM-6 module provides six (6) sets of three (3) push-button switches for manualsystem control. Each switch has three (3), associated
LEDs to indicate Fan / Damper / Motor status: OFF ( Red LED),
ON ( Green LED), TROUBLE ( Yellow LED).
PTB Power Termination Board
PTB Power Termination Board
Model PSC-12 comes packaged with a module called the
Power Termination Board (Model PTB). Model PTB is required for operation with Model PSC-12. Model PTB filters the power from the incoming AC mains, and distributes it to the Model PSC-12 power supply and the optional Model
PSX-12 power-supply extender.
Model PTB has an optional connector that can be used during system installation, commissioning and service to provide the technician with a place to plug in their laptop PC, if required. Model AC-ADPT is an optional accessory cable that allows connection on one side to Model PTB, via a keyed connector and on the other end directly into to the laptop's transformer.
Most laptop-computer external power transformers have removable AC power cords, which can be replaced by the optional Model AC-ADPT to temporarily provide an AC power source for laptop-PC usage during system installation, service and maintenance calls when needed.
PSX-12 Power Supply Extender
PSX-12 Power Supply Extender
The Power Supply Extender (Model PSX-12) is a high-current, auxiliary power supply that expands the main Model PSC-12 power supply and battery charger of the FireFinder XLS system with an additional 24VDC power. Model PSX-12 is rated at 12 Amps.
PSC-12 Power Supply Charger Module s Industry, Inc.
Building Technologies Division
FireFinder XLS Components
─ (cont.’d)
RNI Remote Network Interface
RN
I
Remote Network Interface
The Remote Network Interface (Model RNI) provides a connection point for use with equipment mounted in a remote-lobby enclosure on the FireFinder XLS FACP.
Model RNI is used to provide additional input, output and control features to the system remotely, via the main control panel. These additional features may include control switches and indicators: (Models SCM-8, LCM-8 and
FCM-6), remote-emergency paging microphones or telephones: (Models LVM, FMT), or controls used in graphic annunciators (Models SIM16, OCM-16) or systemstatus display with the ability to acknowledge alarms,
silence audibles and reset the system (Model SSD-C-
REM). Model RNI allows Model PMI to be mounted in the
Model REMBOX2 or Model REMBOX4 remote lobby enclosure.
RPM Remote Printer Module
RPM Remote Printer Module
The Remote Printer Module (Model RPM) provides a means of connecting the FireFinder XLS system to a printer, such as Model PAL-1, for creating a hard copy of system status and configuration reports. Simultaneously, Model
RPM provides an output port that can be configured to communicate with external systems.
Models SSD-C and SSD-C-INT have an integral keyswitch that enables these control buttons to operate.
Model SSD-C-REM is located within a locked cabinet.
Hence, no additional keyswitch is required for enabling the control buttons.
CAB1 Single Row Enclosure
CAB1 Single Row Enclosure
Model CAB 1, the smallest of the FireFinder XLS enclosures, can house a single Model CAB-MP cabinet mounting plate for mounting card cages, power supplies and bulk amplifiers. Model CAB1 also has four (4) mounting slots on the inner door for mounting Model PM I and Model I D-MP switch module brackets.
Model CAB1 comes complete with a black back box; black inner and outer doors; a single lock and key set on the outer door; a single, installed cabinet mounting plate (Model
CAB-MP), and a single, installed outer door lens plate
(Model OD-LP). A red version (Model CAB1R ) is also available – approximate size: 27" (68.6cm.) high, 26"
(66cm.) wide, and 8" (20.3cm.) deep.
System-Status Display
SSD-Series System-Status Display
The System Status Display (SSD-series model displays) is a remote LED / LCD display that shows the local status of a
FireFinder XLS system. An LED illuminates when Alarm,
Supervisory, Trouble, and Security events occur on the system. A (4) four-line liquid-crystal display (LCD) will give details of the event in alphanumeric form.
The display can be toggled to display additional events.
Optional remote system control capabilities are available.
Models SSD-C, SSD-C-INT, and Model SSD-C-REM have three
(3) additional control buttons to acknowledge events,
silence audible circuits, and reset the system. s Industry, Inc.
Building Technologies Division
MDACT - Multi-Point Digital Alarm
Communicator Transmitter
MDACT - Multi-Point Digital Alarm Communicator
Transmitter
The Multi-Point Digital Alarm Communicator Transmitter
(Model MDACT) is used in FireFinder XLS systems where point identification of Alarm, Supervisory, Security and
Trouble events is required at Central or Remote Receiving
Stations. An intelligent RS-485 communications protocol transmits all system information to Model MDACT.
The installer selects the specific event or groups of events that are set to transmit from Model MDACT over phone lines to listed receiving station equipment. In turn, Model MDACT can transmit point information, via the
Ademco Contact ID and the SIA protocol. A Mounting Plate
(Model MOM2-XMP), MOM-2 card cage, and an XMI
Interface Card are required for installation.
FireFinder XLS Components
─ (cont.’d)
TSP-40A Thermal Strip Printer
TSP-40A Thermal Strip Printer
The thermal strip printer (Model TSP-40A) is designed for use with the FireFinder XLS system. Model TSP-40A acts as an event-logging device, providing a permanent history report of all system activity. Model TSP-40A mounts in the FireFinder XLS Model CAB 1, Model CAB2 or Model CAB3 enclosure, and its printout is visible through a window in the locked-door enclosure. Printouts are automatically spooled onto a take-up reel for tidy, uniformed records storage.
CAB2 Two-Row Enclosure
CAB2 Two-Row Enclosure
The Two-Row Enclosure (Model CAB2) is the mid-sized
FireFinder XLS enclosure capable of housing up to two
(2) Model CAB-MP cabinet mounting plates. The inner door has two (2) rows of four (4) mounting slots. The outer door has space for mounting two (2) outer door plates (Models OD-LP, OD-BP or OD-GP). The outer door can be configured to open from either side. Model CAB2 consists of the Model CAB2-BB back box, the Model CAB2-
BD black inner and outer door package, and one (1) Model
OD-LP lens plate. The outer door has a single lock and key set installed. A red version (Model CAB2 R ) is also available.
Approximate size is 45” (114.3cm.) high, 26” (66cm.) wide, and 8” (20.3cm.) deep.
The outer door can be configured to open from either side. Model CAB3 consists of the Model CAB3-BB back box, the Model CAB3-BD black inner and outer door package, and one (1) Model OD-LP lens plate. The outer door has two (2) locks and key sets installed. A red version (Model
CAB3 R ) is also available. Approximate size is 63"
(160cm.) high, 26" (160cm.) wide, and 8" (20.3cm.) deep.
Enclosure Trim Kits
Trim kits are available for all system enclosures for semiflush mounting applications. Model CAB1-TK (for black enclosures) and the Model CAB1 R -TK (for red enclosures) fit inside the Models CAB1 and CAB1-R enclosures.
Similarly, Models CAB2-TK and CAB-2 R -TK fit inside the
Model CAB-2 enclosure, while Models CAB3-TK and CAB3 R -
TK fit the Model CAB-3 enclosure.
Remote Transponders
The FireFinder XLS system can use remote transponders for mounting additional modules such as amplifiers without requiring Model PMI or any control switches.
Special doors are available for systems using Model CAB-2 or Model CAB-3 remote transponders. These doors
(Models CAB2-XBD and CAB3-XBD) omit the unused inner door, and come complete with ventilation louvers built into the door.
Model CAB2-XBD fits into Model CAB2-BB, and Model
CAB3-XBD fits into Model CAB3-BB. Model CAB2-XBD and
CAB3-XBD are supplied in black. Red versions (Models
CAB2-X R D and CAB3-X R D) are also available. Complete box and door kits are available, Models CAB2-X and CAB3-X.
CAB-MP Cabinet Mounting Plate
CAB-MP Cabinet Mounting Plate
The Model CAB-MP cabinet mounting plate provides mounting for a single row of modules in a FireFinder XLS cabinet. Four (4) module spaces are available on Model
CAB-MP, which is used to mount the Model CC-5 card cage; the Model CC-2 card cage; the Model PSC-12 power supply; the Model PSX-12 power-supply extender, and the
Model ZAM-80 / 180-zone amplifiers.
CAB3 Three-Row Enclosure
CAB3 Three-Row Enclosure
Model CAB3, the single largest FireFinder XLS enclosure available, can house a maximum three (3)
Model CAB-MP cabinet mounting plates in the enclosure, and three (3) rows of inner-door mounting slots. s Industry, Inc.
Building Technologies Division
I
D-MP Inner Door Mounting Plate
FireFinder XLS Components
─ (cont.’d)
I
D-MP Inner Door Mounting Plate
The inner door mounting plate (Model I D-MP) is mounted on the inner door of any given model CAB enclosure. Model I D-MP plates are used to mount switch-control modules (Model SCM-8); LED control modules (Model LCM-8), or fan-control modules (Model
FCM-6).
Four (4) mounting plates are included in each Model I D-
MP. Each mounting plate has four (4) spaces for control modules, and can hold either four (4) Model SCM-8 modules (one [1] control module space for each module); four (4) LCM-8 (one [1]control module space for each module), or two (2) Model FCM-6 modules (two
[2] module spaces for each module).
Combinations are also allowed. Blank spaces in Model I D-
MP can be covered using the blank-control-module plate (Model BCM). Up to four (4) Model I D-MP modules can be mounted in a single row on the inner door.
OD-LP Outer Door Lens Plate
OD-LP Outer Door Lens Plate
The Outer Door Lens Plate (Model OD-LP) is a clear plastic lens plate mounted on the outer door of a system cabinet. It is used to allow operators to see the system interface and controls mounted on the inner door, but restricts access to unauthorized users. It covers an entire row on the outer door. A single lens plate is included with each OD-LP.
OD-BP Outer Door Blank Plate
OD-BP Outer Door Blank Plate
The Outer Door Blank Plate (Model OD-BP) is used to cover an entire row on the outer door of a system cabinet. It is used when there is no PMI or control modules mounted on the adjacent row of the inner door.
A single, blank plate is included in each Model OD-BP.
I
D-SP Inner Door Blank Single Plate
I
D-SP Inner Door, Blank Single Plate
The inner door, blank single plate (Model I D-SP) is used to cover any single-module blank spaces on the inner door not used to mount Model PMI or Model I D-MP. Up to four (4) Model I D-SP modules can be mounted in a single row on the inner door. Two (2) blank plates are included in each Model I D-SP.
I
D-FP Inner Door Full-Blank Plate
Model I D-FP is a blank plate that covers the full opening of the row on an inner door, and is used for applications requiring full, dead-front protection. A single, full blank plate is included in Model I D-FP.
BCM Blank Control Module Plate
BCM Blank Control-Module Plate
Model BCM plates can be mounted on a single I D-MP.
Four (4) blank module plates are included in each
Model BCM.
OD-GP Outer Door Grill Plate
OD-GP Outer Door Grill Plate
The Outer Door Grill Plate (Model OD-GP) also covers an entire row on the outer door of a system cabinet, but has four rows of ventilation louvers on it. The OD-GP is mounted in front of system bulk amplifiers, card amplifiers, or other modules that generate heat. Using the
OD-GP will permit airflow across these modules to aid in heat dissipation. A single grill plate is included with each OG-GP.
Remote System Enclosures
Models REMBOX2 and REMBOX4 are FireFinder XLS system enclosures that are used for remotely mounting inner-door modules like the Model PMI interface, switch modules, Model LVM live voice modules, and Model FMT firefighters master telephone modules. Models REMBOX2 and REMBOX4 are thinner than the regular CAB series of enclosures – just 5" (12.7cm.) deep overall, and are perfect for mounting in places where space is limited (e.g. – officecomplex lobbies or behind a receptionist's desk). s Industry, Inc.
Building Technologies Division
FireFinder XLS Components
─ (cont.’d)
No card cages, power supplies or bulk amplifiers can be mounted in a given REMBOX because of their smaller depth. However, Model PMI and modules (e.g. – the remote network interface module [Model RNI], the output control module [Model OCM-16], and the supervised input module [Model SIM-16]) can be mounted in a given REMBOX.
Due to the depth of the live voice module and the firefighters’ master telephone, no Model OCM-16 or Model
SIM-16 modules can be used simultaneously with Model
LVM or Model FMT. The REMBOX2 and the REMBOX4 are designed for flush mounting with no trim kit required.
Both enclosures also come with a clear lens plate on the cover.
A bracket known as Model REMBOX4-MP can be used to mount up to eight (8) output control modules (Model
OCM-16) or supervised input modules (SIM-16). The
REMBOX4-MP must be purchased separately.
Approximate size of the REMBOX4 is 24" (61cm.) wide,
18-1/2" (47cm.) high and 5" (12.7cm.) deep.
NRC Network Ring Card
NRC Network Ring Card
Model NRC (FM approval pending) provides XNET, peer-topeer communication between FireFinder XLS systems. One
(1) Model NRC is required for each XLS panel, in order to allow FireFinder XLS nodes to be wired in a Class A, Style 7 ring topology.
REMBOX2 Two Module Remote Enclosures
REMBOX2 Two Module Remote Enclosures
REMBOX2 has two (2) inner-door module spaces, and can hold a single Model PMI, up to two (2) switch module brackets and one (1) Model LVM. Combinations are also allowed.
REMBOX2 can also mount a single RNI remote network interface on a bracket included in the backbox. A bracket called the REMBOX2-MP can be used to mount up to four
OCM-16 output control modules or SIM-16 supervised input modules. Model REMBOX2-MP must be purchased separately. Approximate size of REMBOX2 is 14-1/2"
(36.8cm.) wide, 18-1/2" (47cm.) high and 5" (12.7cm.) deep.
NCC-G - Network Color Graphics
NCC-G - Network Color Graphics
Model NCC-G is a PC-based, color-graphics command center designed for use with the XNET network, and provides full control and annunciation for a XNET network for a maximum 63 XLS, MXL-IQ or MXL systems. The NCC-G is used to monitor and control alarms, troubles, security, supervisory and all system events from one of many XLS systems.
Model NCC-G maintains an extensive history log of all system events and has extensive report generation capabilities. User programmable function buttons allow site specific control functions. Multiple NCC-Gs may be connected to XNET network. Each NCC-G ordered separately.
REMBOX4 Four-Module Remote Enclosures
REMBOX4 Four-Module Remote Enclosures
Model REMBOX4 has space for mounting four (4) innerdoor modules. Any combination of Model PMI (twomodule spaces); switch module brackets; Model LVM, or Model FMT (one-module space each) can be used.
Unused module spaces can be covered with Model ID-SP blank plates. The REMBOX4 can also mount a single remote network interface (Model RNI) on a bracket included in the backbox. s Industry, Inc.
Building Technologies Division
MLC - MXL Line Card [for FireFinder XLS]
FireFinder XLS Components
─ (cont.’d)
MLC - MXL Line Card [for FireFinder XLS]
The MXL Line Card (Model MLC) is an optional card for the FireFinder XLS panel that supplies two (2) intelligent analog circuits, utilizing the Model ‘ I ‘ series;
Model ‘ ID ‘ series; Model ‘ IL ‘ series or Model ‘ FP ‘ seriestype intelligent devices. Model MLC occupies two (2) addresses on the HNET network, and devices connected to the Model MLC circuits are dynamically supervised by
FireFinder XLS through the use of a unique communications protocol.
XLS-MLE6-ADPT
XLS-MLE6/ R -ADPT − XLS MLE-6/ R Enclosure Adapter
Model XLS-MLE6-ADPT, which must be used in conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in oldergeneration MXL Model MLE-6 large black enclosures.
Model XLS-MLE6 R -ADPT, which must be used in conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in oldergeneration MXL MLE-6 R large red enclosures.
XLS-MSE2-ADPT
XLS-MSE2/ R -ADPT − XLS MSE-2/ R Enclosure Adapter
Model XLS-MSE2-ADPT, which must be used in conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in oldergeneration MXL Model MSE-2 small black enclosures.
Model XLS-MSE2 R -ADPT, which must be used in conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in oldergeneration MXL Model MSE-2 R small red enclosures.
XLS-MSE3-ADPT
XLS-MSE3/ R -ADPT − XLS MSE-3L/ R or MSE-3M/ R
Model XLS-MSE3-ADPT is an adapter that allows
FireFinder XLS cards to be mounted in oldergeneration MXL-IQ Model MSE-3L or Model MSE-3M black enclosure.
Model XLS-MSE3 R -ADPT is an adapter that allows
FireFinder XLS cards to be mounted in older- generation MXL-IQ Model MSE-3L R or Model MSE-3M R red enclosure.
XLS-MME3-ADPT
XLS-MME3/ R -ADPT − XLS MME-3/ R or MBR-2
Model XLS-MME3-ADPT, which must be used in conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in older- generation MXL Model MME-3 or Model MBR-2 medium black enclosures.
Model XLS-MME3 R -ADPT, which must be used in conjunction with Model CAB-MP, is an adapter that allows FireFinder XLS cards to be mounted in oldergeneration MXL Model MME-3 R medium red enclosures.
XLS-RCC1-ADPT
XLS-RCC-1-ADPT − XLS RCC-1 Enclosure Adapter
Model XLS-RCC1-ADPT is an adapter that allows the
FireFinder XLS Model SSD/-C series remote annunciator to be mounted in older-generation Model RCC-1 surfacemount enclosure.
XLS-RCC13F-ADPT s Industry, Inc.
Building Technologies Division
FireFinder XLS Components
─ (cont.’d)
XLS-RCC13F/ R -ADPT − XLS RCC-1F/ R or RCC-3F/ R
Model XLS-RCC13F-ADPT is an adapter that allows the
FireFinder XLS Model SSD/-C series remote annunciator to be mounted in older-generation Model RCC-1F or Model
RCC-3F black, flush-mount enclosure.
Model XLS-RCC13F R -ADPT is an adapter that allows the
Model SSD/-C series to be mounted in older-generation
RCC-1F R and RCC-3F R , red flush-mount enclosure.
Details for Ordering
Model
Number
Part
Number
Description
── 599-050092 PMI and GPMI
AC-ADPT 500-633992
CAB-1
CAB-1R
[four (4) per package]
500-633007 Complete single-row cabinet, black
500-633728 Complete single-row cabinet, red
CAB1-TK 500-633013 Single-row trim-kit cabinet, black
CAB1 R -TK 500-633729 Single-row trim-kit cabinet, red
CAB2-BB 500-633009 (2) Two-row back box, black
CAB2R B
CAB2-BD
500-634941 (2) Two-row back box, red
500-633008 (2) Two-row inner & outer door set, black
CAB2R D
CAB2-TK
500-633755 (2) Two-row inner & outer door set, red
500-633014 (2) Two-row trim-kit cabinet, black
CAB2 R -TK 500-633753 (2) Two-row trim-kit cabinet, red
CAB2-XBD 599-633768 CAB2 transponder door
CAB2-X R D 500-633792 red
CAB3-BB
[mounts to CAB2R B]
500-633011 (3) Three-row back box, black
CAB3R B 500-634942 (3) Three-row back box, red
Details for Ordering ─ (continued)
Model
Number
Part
Number
Description
LCM-8 500-033100
[used for FireFinder XLS]
Mounting plate for Model MOM-2
MOM2-XMP 500-634822
[used for FireFinder XLS]
MXL module card cage
MOM-2 500-892766
NIC-C
[one (1) full slot]
500-033240 Network
NRC
OD-BP
OD-BPR
500-050337 Network ring card
500-633017 Outer door blank plate
500-634919 Outer door blank plate, red
OD-GPR
OD-GP
500-634920 Outer door grill plate, red
500-633018 Outer door grill plate
OD-LP 500-633016 Outer door lens plate
PAL-1 500-692407
PMI 500-033070 Person machine interface
PMI-INT 500-034160
Person machine interface
[with multi-lingual overlays]
PSC-12 500-033340
[12A @ 24VDC]
[12A @ 24VDC]
PTB 500-033390 Power termination board
(2) Two-module remote lobby enclosure, black
REMBOX2 R 500-650612 (2) Two-module remote lobby enclosure, red
REMBOX2-MP 500-634211
Mounting plate for Models
OCM-16 / SIM-16 in Model REMBOX2
REMBOX4 500-633914 (4) Four-module remote lobby enclosure, black
REMBOX4-MP 500-634212
Mounting plate for Models OCM-16 /
SIM-16 in Model REMBOX4
REMBOX4 R 500-650613 Four-module red
RNI
RPM
500-033420 Remote network interface module
500-033270 Remote printer module
SIM-16 500-034060 Supervised input module
CAB3R D
CAB3-TK
500-633757 (3) Three-row inner & outer door set, red
500-633015 (3) Three-row trim-kit cabinet, black
CAB3 R -TK 500-633754 (3) Three-row trim-kit cabinet, red
CAB3-XBD 599-633769 CAB3 transponder door
SSD-C 500-648733 System-status display with control
SSD-INT 500-034740 System-status display with multi-lingual overlays
SSD-C-INT 500-034750
SSD-C-REM 500-634773
System-status display with control and multilingual overlays
System-status display with control for remote lobby enclosure
CAB3-X R D 500-633793 red
CAB-MP
[mounts to CAB3R B]
500-633012 Back box module mounting plate
CAN Cable
3 ft. (91.4 cm.) Length required for:
CCL 599-634214
I nner Doors and from Row-to-Row on
CC-2
Model CAB-series Inner Doors
500-633440 Two (2) slot card cage
CC-5 500-633037 Five (5) slot card cage
CDC-4
CSB
500-034200 Conventional detector card
Controllable card
500-033130 CAN Sounder Board
FCM-6 500-033140
GPMI-UK 500-650066
Software-upgrade kit for PMI
{to allow global functionality}
HLIM
I D-FP 500-633029 (4) Four module inner-door blank plate
I
I
D-MP 500-633027
Inner-door enclosure mounting plate,
[four (4) per package] mounting plate,
[two (2) per package] s Industry, Inc.
Building Technologies Division
TSP-XB
TSP-XC
XLS-MLE6-ADPT
XLS-MLE6 R ADPT
XLS-MME3-ADPT
XLS-MME3 R -ADPT
XLS-MSE2-ADPT
XLS-MSE2 R -ADPT
500-849949 Brackets for thermal-strip printer
500-849950 Cables for thermal-strip printer
S54430-C9-A1 MLE-6 enclosure adapter for XLS, black
S54430-C9-A2 MLE-6 R enclosure adapter for XLS, red
S54430-C8-A1
MME-3 and MBR-2 enclosure adapters for
FireFinder XLS, black
S54430-C8-A2 MME-3 R enclosure adapter for XLS, red
S54430-C7-A1 MSE-2 enclosure adapter for XLS, black
S54430-C7-A2 MSE-2 R enclosure adapter for XLS, red
XLS-MSE3-ADPT
XLS-MSE3 R -ADPT
S54430-C14-A1
S54430-C14-A2
MXL-IQ MSE-3L and MSE-3M enclosure adapters for
XLS, black
MXLI Q MSE-3L R & MSE-3M R enclosure adapters for XLS, red
XLS-RCC1-ADPT S54430-Z14-A1 RCC-1enclosure adapter for XLS-SSD, black
XLS-RCC13F-ADPT S54430-Z13-A1 RCC-1F & RCC-3F enclosure adapters, black
XLS RCC13F R ADPT
ZIC-2C
ZIC-4A
ZIC-8B
S54430-Z13-A2 RCC-1F R & RCC-3F R enclosure adapters, red
500-648671 (2) Two-channel adapter card, (ZIC-8B)
500-033050 (4) Four-circuit zone indicating card
500-648670 (8) Eight-circuit zone indicating card
Note: Products are UL 864 9 th Edition Listed for indoor dry locations within a temperature range of 120+/-3°F
(49+/-2°C) to 32+/-3°F (0+/-2°C) and a relative humidity of 93+/-2% at a temperature of 90+/-3°F (32+/-2°C).
Notice: This marketing data sheet is not intended to be used for system design or installation purposes.
For the most up-to-date information, refer to each product’s installation instructions.
s Industry, Inc.
Building Technologies Division
Fire Safety
8 Fernwood Road
Florham Park, NJ 07932
Tel: (973) 593-2600
FAX: (908) 547-6877
URL: www.SBT.Siemens.com/FIS
(SII‐FS)
Printed in U.S.A.
Fire Safety
2 Kenview Boulevard
Brampton, Ontario
L6T 5E4 / Canada
Tel: (905) 799-9937
FAX: (905) 799-9858
October 2011
Supersedes sheet dated 8/11
(Rev. 7)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project