Eurostove WESTFIRE UNIQ23 Installation Manual And Operating Instructions


Add to my manuals
22 Pages

advertisement

Eurostove WESTFIRE UNIQ23 Installation Manual And Operating Instructions | Manualzz

WESTFIRE INSET STOVES

MODELS: WF32/UNIQ 32 NARROW AND WIDE FRAME, WF23/UNIQ 23 INSET STOVE

IMPORTANT

These appliances will become very hot during operation; a glove is provided for use when the stove is hot.

We recommend that a guard should be used for the protection of the young, elderly and vulnerable. Do not burn rubbish or pre sawn / treated timber in this appliance.

Please read the instruction manual carefully before installation and use. Please keep this manual for future reference.

UK:

Installation Manual and Operating instructions

WESTFIRE WF23/UNIQ 23 INSET, WESTFIRE WF32/UNIQ32 INSET

This manual refers to the stove type listed above, which has been tested in accordance with

EN13240.

Congratulations on your purchase of a new wood burning stove from Westfire ApS. Please read this manual carefully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems. Please note that “all local regulations, including those referring to national and European

Standards, need to be complied with when installing this appliance”.

For further information on installing and using fireplaces and wood burning stoves, please see the relevant building regulations that apply to the country in which WESTFIRE WF32/UNIQ32 AND WF23/UNIQ23 has been approved, as well as the relevant brochure on the correct use of wood burning stoves available from your local stove supplier or your Chimney sweep.

These instructions cover the basic principles to ensure the satisfactory installation of the

WESTFIRE WF23/UNIQ23 and WF32/UNIQ 32 inset wood stove, although detail may need slight modification to suit particular local site conditions.

In all cases the installation must comply with current Building Regulations, Local Authority

Byelaws and other specifications or regulations as they affect the installation of the stove.

It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303, BSEN15287 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J.

HEALTH AND SAFETY PRECAUTIONS

Special care must be taken when installing the stove such that the requirements of the Health and Safety at

Work Act are met.

Handling

Adequate facilities must be available for loading, unloading and site handling.

Fire Cement

Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash immediately with plenty of water.

Asbestos

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment.

Metal Parts

When installing or servicing this stove care should be taken to avoid the possibility of personal injury.

STOVE PERFORMANCE & TESTING

The WESTFIRE WF23/UNIQ23 and WF32/UNIQ 32 insets have been approved in accordance with EN 13240.

Stove model Weight Nominal heat output

Wood Smokeless fuels

WF32/UNIQ32 INSET

WF23/UNIQ23 INSET

112kg

92kg

5.9KW

6.1KW

N/A

N/A

PREPARATORY WORK AND SAFETY CHECKS - IMPORTANT WARNING

This stove must not be installed into a chimney that serves any other heating appliance.

There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room.

Chimney- Chimney Connection -

Flue Diameter 150mm (160cm2)

In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught so as to clear the products of combustion and prevent smoke problems into the room.

WF32/UNIQ32 INSET WF23/UNIQ23 INSET

Tested Draft

Max Draft

Flue gas temperature

Flue gas flow

12pa

25pa

243°c

4.6g/sec

12pa

25pa

281° c

5.2 g/sec

NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory. Alternatively the calculation procedure given in BS

5854:1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught.

Installing the appliance

Each Installation is different for every property and it is not possible to give detailing for every installation.

The Installation must comply with Building regulations and follow best practice construction methods.

Typical fireplace constructions have a supporting lintel. Do not remove lintel without support of the main building structure of the building. Do not use the appliance to support the structure.

The outlet from the chimney should be above the roof of the building in accordance with the provisions of

Building Regulations Approved Document J.

If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house. Older properties, especially, may have chimney faults or the cross section may be too large i.e. more than 160 mm x 160 mm. Remedial action should be taken, if required, seeking expert advice. If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J.

Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire.

NOTE- When installing the Uniq32/WF32 or Uniq 23/WF23 inset in to a fire place opening with a traditional flue we recommend installation of the appliance with flue liner for optimum performance.

If there is no existing chimney then either a prefabricated block chimney in accordance with Building

Regulations Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used.

These chimneys must be fitted in accordance with the manufacturer’s instructions and Building Regulations.

A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less than the size of the outlet socket of the stove. Any bend in the chimney or connecting fluepipe should not exceed 45  . 90  bends should not be used.

If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should in its closed position leave a minimum continuous opening free area of at least 20 % of the total cross sectional area of the flue or fluepipe.

Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and connecting flue pipe

WF 23 / UNIQ 23 BUILDERS

APERTURE SIZE

WF23/UNIQ 23, WF 32 / UNIQ 32

DOOR REMOVAL

WF 32 / UNIQ 32 BUILDERS

APERTURE SIZE

420mm

Narrow frame model

Wide frame model

Installing the appliance

I)

II)

Remove door and frame a. Open door and lift so bottom hinge in lifts out of holder. b. Tilt base away from stove and lower door. c. Door should now be released. d. Place door in a safe place.

Remove frame from stove. a. Once door is removed b. Loosen four Allen keys and frame will come away.

III)

IV)

V)

VI)

X)

XI)

Remove Brick set a. See manual below

Remove Bar from flue collar a. Loosen bolts holding flue collar

b. Remove flue collar taking care not to lose nuts and bolts.

Fit collar to stainless steel flue( we recommend a 500mm of 1mm stainless steel if possible)

Fill any Void with at the back and sides with a 6;1 vermiculite to cement mix or any other good quality non-combustible insulation material. It is important that the back and sides of

VII) the stove are well insulated.

Connect the stove to the flue a. Pull stove collar to top of stove from inside the appliance. b. Align bolt locations and re-bolt the spigot( and Flue) to stove. c. Tighten bolts and secure.

VIII) Finish around stove

IX) Re-fit frame a. If a newly plastered room please take care not to leave painted frame and door fitted as the extremes of moisture while the plaster dries and can cause corrosion to the paint work. b. Before re-fitting door and frame, store door and frame in a dry and well ventilated place while allowing the plaster to dry

Re-fit door

Re-fit brick as shown in the instructions in this booklet.

Typical installation of an inset stove

Distance to Combustible materials

Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues could ignite it. Therefore when installing the stove in the presence of combustible materials due account must be taken of the guidance on the separation of combustible material given in Building

Regulations Approved Document J and also in these stove instructions.

WF32/UNIQ32 INSET WF23/UNIQ23 INSET

Distance to combustible materials rear

Distance to combustible materials side

300mm

200mm

200mm

350mm

Distance to soft furnishing in front 1100mm 1100mm

The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove .

Hearth

The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not independently supported.

The WESTFIRE WF23/UNIQ 23 INSET, WESTFIRE WF32/UNIQ32 INSET wood inset stove has been tested and is suitable to be installed above a 12mm non combustible plate such as Westfire 12mm glass plates or 20mm slate plates. Installation of the stove must be at a minimum height of 450mm for 12mm hearth. Installation of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J.

The clearance distances to combustible material beneath, surrounding or upon the hearth and walls adjacent to the hearth should comply with the guidance on the separation of combustible material given in

Building Regulations Approved Document J and also in these stove instructions.

If the stove is to be installed in front of a wooden floor, it must be covered with a non-combustible material at least 12mm thick, in accordance with Building Regulations Approved Document J, to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber.

Combustion air supply

In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the stove is installed to provide combustion air. This is particularly necessary if the room is double-glazed or a flue draught stabiliser is operating in the same room as the appliance. The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J. An opening window is not appropriate for this purpose. Air inlets must be positioned in such a way that they cannot be blocked. An air inlet may be a vent (the vent must be open and the capacity of the vent sufficient when the stove is lit) or a fresh air system linked to the stove.

The WESTFIRE WF23/UNIQ 23 INSET has an option of a closed air supply collar; this enables the stove to take all combustion air (primary, secondary and tertiary) directly from outside with a 100mm pipe from the stove.

The WESTFIRE WF32/UNIQ 32 INSET does not have a closed combustion option.

FLUE AND AIR INTAKE POSITIONS

Distance from rear to centre of top flue exit

Distance from floor to centre of rear flue exit

WF32/UNIQ32 INSET

150mm

N/A

Distance from top of appliance casing to centre of Air intake.

N/A

WF23/UNIQ23 INSET

135 mm

N/A

500mm

WESTFIRE WF23/ UNIQ 23 INSET MODEL

WESTFIRE WF32 / UNIQ 32 INSET NARROW FRAMED MODEL

810.00mm

405mm

WESTFIRE WF32/ UNIQ 32 INSET WIDE FRAMED MODEL

WESTFIRE WF23/UNIQ 23 INSET, WESTFIRE WF32/UNIQ32 INSET

WF32/UNIQ32 INSET

Narrow frame

WF32/UNIQ32 INSET

Wide frame

WF23/UNIQ23 INSET

Std frame

Height (frame)

Width (frame)

Height (stove box)

Width (stove box)

Depth (stove box)

610mm

880mm

555mm

810mm

405mm

570mm

1000mm

555mm

810mm

380mm

660mm

670mm

600mm

610mm

375mm

Closed combustion fitted as standard

NOT AVALIABLE NOT AVAILABLE OPTIONAL

Westfire Insulated chambers

The WESTFIRE WF32/UNIQ32 AND WF23/UNIQ23 stove is lined with heat deflection panels and baffles, these panels are designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These baffles should not be removed other than for cleaning the stove. Any defective panels should be replaced.

Commissioning and handover

Ensure loose parts are fitted in accordance with the instructions given in the instruction booklet.

On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, a small fire may be lit to check that smoke and fumes are taken from the stove up the chimney and emitted safely into the atmosphere. Do not run at full output for at least 24 hours.

On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and notify them to use only the recommended fuels for the stove.

Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to use a fireguard to BS 6539 in the presence of children, aged and/or infirm persons.

Operating your stove-

WESTFIRE WF23/UNIQ 23 INSET, WESTFIRE WF32/UNIQ32 INSET

The first lighting of your stove.

The heat-resistant paint on your stove will cure and harden the first time you light your appliance. The curing process produces a good deal of smoke and odour, it is therefore important that the first time you light your stove the room should be well ventilated. During the process it is important to open and close the stove door periodically (every 30mins) during the first couple of firings therefore preventing the door seal cord around the door from sticking and coming away from the door. Once the heat-resistant paint has hardened the smell will disappear.

This stove is NOT designed to be used with the door open, the stove door must be kept closed except when lighting the stove, adding firewood or removing ash in order to prevent flue gases from escaping.

NOTE! Always use dry wood for your stove, your stove will burn better and more efficiently with better quality dry wood. Wet wood will cause your stove to burn inefficiently.

Lighting your appliance

Quality Firelighters should be used when lighting the stove. (Never use mentholated spirit, petrol or other flammable liquids). Lighting your stove with firelighters will be more reliable and easier than using paper.

To light your stove

1. Place a few smaller pieces of dry wood (kindling) in the stove on top of the non toxic firelighters, place one or two small dry split (¼ split) logs on top.

2. Fully slide open the secondary air slider. Pull out fully primary air slider. The stoves air supplies are now fully open.

3. Light the firelighters and push door to closed position but do not close latch, this will allow a small gap of 1cm for more air to be supplied to stove.

4. After approximately 10 minutes when the fire is burning brightly shut latch on the door.

5. Once fire is hot push in fully the primary air slider. This will close off the primary air control to the stove. If the stove begins to die when the primary is closed, open slider again and leave open for another ten minutes.

5. After approximately another 10 minutes close the secondary air slider to the specified position for the stove (See table). For the stove to burn cleanly plenty of secondary air is needed, please do not be tempted to shut the fire down too early as this may cause smoke. At nominal heat output, expect to refuel your stove approximately once an hour.

The WESTFIRE WF23/UNIQ 23 INSET, WESTFIRE WF32/UNIQ32 INSET stoves are all equipped with a control level for secondary air designed to ensure a plentiful supply of oxygen during firing. When lit, the stove will get very hot and due care must therefore be exercised. Please use a glove and operating tool supplied when operating levers and dampers.

RE-FUELING

To re-fuel your stove in the cleanest way.

Only refuel your stove when flames have died down and you have glowing embers.

Before refuelling, open secondary air slider fully, also open primary air slider fully and leave for 5 minutes.

Open door gently, add two pieces of wood measuring approx 33cm with a combined weight of approx

1.5kg and close the door. Leave the air sliders open for 10 minutes to allow the fire to reach a good temperature. Close (push in) primary air slider and slide secondary air slider to position for the stove.

In the event of a chimney fire: Close the air damper and the stove door, and call 999 or your local fire department.

If your stove is overheating close all air sliders and the door must be closed, and left until the stove has returned to nominal temperature.

Basic Positions of dampers during operation (nominal)

WF23/UNIQ 23

WF 32/UNIQ 32

Secondary air

60% open

30% open

Primary air closed closed

You will need to become familiar with your stove in order to be able to regulate the secondary air intake correctly, as factors such as the quality and height of your chimney, the quality of your fuel and the external conditions play a large role in your stove performance. It is easy to see whether the stove is functioning correctly; however incomplete combustion may lead to a build-up of hard, shiny soot on the inside of your stove and glass.

To prevent sooting of the chamber and glass introduce secondary air, also check that your wood is dry.

It is important to check the draft conditions before lighting your stove. This may be done, for instance, by crumpling a piece of newspaper, placing it in the combustion chamber and lighting it. The draft conditions are good if the smoke is drawn away through the chimney.

CONTROLS on WESTFIRE WF 32 /UNIQ32 INSET

CONTROLS on WESTFIRE WF 23 /UNIQ 23 INSET

Door operation

When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from possible heat.

WOOD FUEL

IMPORTANT: Never use toxic wood such as chipboard, impregnated, painted wood or pre-sawn wood

such as pallets.

Good quality wood is the most important factor in your stove working efficiently and cleanly. Always use dry firewood. The dryness of the firewood plays an important role since the use of wet wood results in poor fuel economy and may cause a tarry sooty film on the internals of the stove.

Newly cut wood contains 60–70% water, making it totally unsuitable for use as firewood.

Newly cut wood should be stacked and air dried under cover for two years before being used as firewood.

SOLID SMOKELESS FUELS- The WESTFIRE WF32/UNIQ32 AND WF23/UNIQ23 stoves are not suitable for use with smokeless fuels. The stove will burn best when burning wood. HOUSE COAL AND PETROLEUM COKE ARE

NOT SUITABLE FOR USE ON THIS STOVE; ITS USE WILL INVALIDATE THE GUARANTEE.

Overnight burning

Westfire Uniq32/WF32 or Uniq 23/WF23, are designed to burn wood. Wood burns more efficiently and cleanly if is burnt hotter. Westfire do not recommend that their stoves are burnt overnight for this reason.

As a night time regime we recommend that the fire is loaded when hot and burnt for five minutes with the secondary air slider fully open until the new wood has taken and is burning, then close the secondary air valve to its operational position.

On returning to the stove in the morning the fire will have burnt out. Reload with some paper or firelighter and some kindling and open all the sliders fully to relight quickly. Beware as the ash bed will have hot embers.

Use of operating tools

Always use the operating tools provided when handling parts likely to be hot when the stove is in use.

Maintenance

WESTFIRE WF23/UNIQ23 and WF32/UNIQ 32 inset wood stoves need to have the ash removed from the stove at regular intervals. Make sure the stove is completely cold before cleaning out ash (embers can remain hot for over 24 hours). To clean the outside of the stove use a dry cloth.

IMPORTANT! – Check for ash build up under and behind the ash pan, ash build-up under ash pan cause primary air to remain open

Annual service

The inside of the stove should be serviced /cleaned once a year. To clean the inside, remove all ash, soot and tar residue from the combustion chamber. Remove insulated chamber panels and baffle, to clean out any dirt and soot will collected behind them. Check the quality of all insulated panels and replace any which are damaged or cracked, replace stove door rope cord in the door. Check glass is correctly positioned.

The stove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer.

The chimney should also be checked for blockages before relighting the stove if it has not been used for an extended period of time.

The paint/ lacquer can wear thin in exposed places due to overheating. This, and other lacquer damage, may be repaired using a Westfire Senotherm paint/lacquer spray available from your Westfire dealer.

Ash must be stored in a non-combustible container and must not be mixed with other combustible waste.

Cleaning the glass

Incorrect firing, for example using wet wood, or slow burning can result in the viewing window becoming covered in soot. This soot can be easily and effectively removed by using a damp cloth or when necessary a proprietary stove glass cleaner or an ordinary scouring liquid, when the glass is cold

Periods of Prolonged Non-Use

If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce condensation and subsequent damage, leave the air controls fully open.

FIRE BRICK INSTALLATION SEQUENCE - WESTFIRE UNIQ 23

Installation procedure:

Vermiculite brick set for the Uniq 23 freestanding and Uniq 23 inset .

1 – Inner Top Turbulence Brick

2 – Left Mid Baffle Brick

1

2 3

3 – Right Mid Baffle Brick

4 – Rear Brick

5 – Left Base Brick

6 – Left Side Brick

7 – Right Base Brick

9

4

10

8 – Right Side Brick

9 – Outer Top Baffle Brick

10 – Rear Base Brick

11 – Front Base Brick

6 5 12,13

11

7

14 12 – Grate Support

13 – Grate

14 – Log Retainer

8

Inner top turbulence brick 1 is positioned on the secondary air pipe with angled edge at rear, sloping down. Brick 1 is held in place with a steel pin.

Left & right mid baffle bricks 2 & 3 positioned with full angled edge at front and part angled edge on the outside. Bricks 2 & 3 need to be fitted lower down and slid upwards into final position.

Rear brick 4 positioned lining up tertiary air holes with angled edge sloping down at rear.

FIRE BRICK INSTALLATION SEQUENCE - WESTFIRE UNIQ 23 - continued

Left base brick 5 positioned.

Left side brick 6 positioned on top of left base brick

5. Left mid baffle brick 2 must be held up to enable brick 6 to be fitted. Brick 2 is then supported by left side brick 6.

Right base brick 7 positioned.

Right side brick 8 positioned on top of right base brick 7. Right mid baffle brick 3 must be held up to enable brick 8 to be fitted. Brick 3 is then supported by right side brick 8.

Outer top baffle brick 9 fitted with angled edge at rear sloping down, resting on rear brick 4 and supported by two side pins.

Rear base brick 10 fitted.

Front base brick 11 fitted.

FIRE BRICK INSTALLATION SEQUENCE - WESTFIRE UNIQ 23 - continued

Grate support 12 fitted.

Grate 13 fitted.

Log retainer 14 fitted.

FIRE BRICK INSTALLATION SEQUENCE - WESTFIRE UNIQ 32

1 – Outer Top Baffle Brick

2 – Left Angled Side Brick

3 – Right Angled Side Brick

4 – Rear Brick

5 - Left Side Brick

6 – Right Side Brick

7 – Left Base Brick

8 – Right Base Brick

9 – Rear Base Brick

10 – Front Base Brick

11 – Base Grate

12 – Log Retainer

13 – Inner Top Baffle Brick

1

13

5 2

7

12

4

11

9

10

8

3 6

Outer top baffle brick 1 must be held in place and then supported by left and right angled side bricks 2 & 3.

Position rear brick 4 below chrome tertiary air bar and push angled side bricks 2 & 3 to butt up against it.

5

1

13

2

7

12

4

11

9

10

8

3 6

7

Left and right side bricks 5 & 6 fitted.

FIRE BRICK INSTALLATION SEQUENCE - WESTFIRE UNIQ 32

Left base brick 7 fitted.

Right base brick 8 fitted.

Rear base brick 9 fitted.

Front base brick 10 fitted.

Base grate 11 fitted.

Log retainer 12 fitted.

Inner top baffle brick 13(Angled parallel edge at rear resting on chrome tertiary air bar) fitted and supported with two side pins.

Trouble shooting

1. Fire will not burn - check a) the air inlet is not obstructed in any way, b) that chimneys and flueways are clear, c) that a suitable fuel is being used, d) that there is an adequate air supply into the room, e) that an extractor fan is not fitted in the same room as the fire.

2. Fire blazing out of control - check a) the doors are tightly closed, b) the air control is turned down to the minimum setting, c) the air inlet damper is closed and that it is not prevented from closing completely by a piece of ash, d) a suitable fuel is being used, e) the door seals are in good condition. f) the chimney draft may be too strong g) ash pan seal h) for ash below ash pan causing pan to not seat correctly and clean out.

3) Soot forms on the window a) The firewood may be too wet b) the intake of secondary air may be insufficient c) fire not hot enough

4) The stove fails to heat fully a) The firewood may be too wet b) the intake of secondary air may be insufficient

5) Smoke or odour a) Weak chimney draft b) check for blockages in the flue pipe/chimney c) check the height of the chimney in relation to the surroundings

6) Soot in the chimney a) The firewood may be too wet b) intake of secondary air may be insufficient

Chimney Fires

If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur turn the air control setting to the minimum, and tightly close the doors of the stove. This should cause the chimney fire to go out in which case the control should be kept at the minimum setting until the fire in the stove has gone out. The chimney and flue ways should then be cleaned. If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately.

After a chimney fire the chimney should be carefully examined for any damage. Expert advice should be sought if necessary

Permanent air vent

The stove requires a permanent air vent to the room or a direct connection to the closed air port at the rear of the stove. This is to provide adequate air supply in order for the stove to operate safely and efficiently.

In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air. This air vent should not under any circumstances be shut off or sealed.

WARNING NOTE

Properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes from de-ashing and re-fuelling may occur. However, persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, then the following immediate action should be taken:-

(a) Open doors and windows to ventilate room

(b) Let the fire go out or eject and safely dispose of fuel from the appliance

(c) Check for flue or chimney blockage and clean if required

(d) Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected.

If necessary seek expert advice.

The most common cause of fume emission is flueway or chimney blockage. For your own safety these must be kept clean at all times.

IMPORTANT NOTES

General

Before lighting the stove check with the installer that the installation work and commissioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean, is sound and free from any obstructions. As part of the stoves’ commissioning and handover the installer should have shown you how to operate the stove correctly.

Use of fireguard

When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be used to prevent accidental contact with the stove. The fireguard should be manufactured in accordance with BS 6539.

Chimney cleaning

The chimney should be swept at least once a year for smokeless fuels and a minimum of twice a year for wood and other fuels. It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period.

If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire.

In situations where it is not possible to sweep through the stove the installer will have provided alternative means, such as a soot door. After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush.

HETAS Ltd Approval

This appliance has obtained HETAS Ltd approval on a safe and fit for purpose level (single tick approval) for burning wood logs only as detailed in list of recommended fuels above. Approval does not cover the use of other fuels either alone or mixed with the recommended fuels listed, nor does it cover instructions for the use of other fuels.

Guarantee

Your new stove is covered by a five year guarantee against manufacturing defects. Your receipt documents the date of purchase. The guarantee does not cover damage caused by faulty operation such as overheating (burning of not recommended fuels) or the stove being incorrectly connected, or damage which occurs as a result of external physical force.

The guarantee does not cover damage to replaceable parts (Firebricks, Cast Grates and Glass), transport costs associated with repairs under warranty or the installation/dismantling of the stove in connection with repairs under warranty. Warning! Any unauthorised modification of the appliance is forbidden.

Only replacement parts recommended by Westfire ApS should be used for repairs.

UK IMPORTER

EUROSTOVE LIMITED, UNIT S5, MENDIP INDUSTRIAL ESTATE,

MENDIP ROAD, ROOKESBRIDGE. SOMERSET. BS26 2UG. TEL: 01934 750500

MAIL: [email protected]