Remotec ZXT-120 Specifications
Add to my manuals
29 Pages
Remotec ZXT-120 is a Z-Wave to AC IR extender that allows you to control your air conditioner with your Z-Wave home control network. It works with any Z-Wave compliant gateway or controller and supports both "Frequently Listening Routing Slaves" (FLiRS) and "Always Listening" node types. The ZXT-120 has a built-in IR code library for most popular air conditioner brands, so you don't need to have any IR control code knowledge. You can also use the learning function to teach the ZXT-120 new IR codes.
advertisement
ZXT-120
(Z-Wave-to-AC IR Extender)
Firmware Version:
V1.0, V1.1, V1.2, V1.4
1
Table of Contents
Introduction .................................................... 3
Controller and Gateway Requirements ............ 4
Built-in IR code library .................................... 4
Glossary .......................................................... 5
ZXT-120 Operations ........................................ 6
Product Overview ............................................. 7
Z-Wave Remote Control ................................... 8
ZXT-120 Information ....................................... 9
Listening Mode Change .................................... 11
IR Code Selection ............................................ 12
IR Code Learning ............................................ 13
Reset ZXT-120 to factory default........................ 17
INSTALLATION ................................................ 18
MOUNTING THE ZXT-120 TO A WALL.................. 18
WIRELESS INFORMATION ............................... 21
MAINTENANCE................................................. 21
FREQUENTLY ASKED QUESTIONS .................... 21
Z-Wave Frequently Asked Questions ................... 21
TECHNICAL SPECIFICATIONS.......................... 23
CHECKING ACCESSORIES ................................ 28
FCC NOTICE .................................................... 28
WARNINGS...................................................... 28
CAUTION ........................................................ 28
WARRANTY ..................................................... 29
2
Introduction
Z-Extender
TM
ZXT-120
(Z-Wave-to-AC IR Extender)
Operating Instructions
The ZXT‐120 is a Z‐Wave to IR extender for air‐conditioner (AC),
(Figure 1), it works with any Z‐Wave compliant gateway or controller by translating Z‐Wave Thermostat Commands to AC IR control code.
User can select the IR code from the built‐in code library of ZXT‐120, or use learning function, by using Z‐Wave Configuration Commands according to the parameter table. ZXT‐120 is also with built‐in temperature sensor which allows gateway or controller to get the current room temperature.
Figure 1 ZXT-120
ZXT‐120 can be configured as either “Frequently Listening Routing
Slaves” (FLiRS) or “Always Listening” node after exclusion process
(before inclusion process).
FLiRS node type is for battery operated applications and it will enter sleep mode frequently in order to conserve battery consumption that can provide the flexibility if there is out of 5Vdc power source. Also,
user can place the unit in anywhere at home.
Always Listening node type is for the needs of fast response application. It works with 5Vdc power source. Always Listening node can act as a repeater, which will re‐transmit the RF signal to ensure that the signal is received by its intended destination by routing the
signal around obstacle and radio dead spots.
ZXT‐120 supports Network Wide Inclusion (NWI) and Explore Frames.
It also supports Z‐Wave networks with multiple gateways and controllers. Like every Z‐Wave accessory, user will need to include the
3
ZXT‐120 into their Z‐Wave network using the primary controller. Then, the user can use either the primary controller or secondary controller to configure and setup the ZXT‐120 using Z‐Wave’s configuration command class. Once the configuration and setup is complete, the controller can use Z‐Wave “Thermostat commands class” to control
their IR‐controlled air‐conditioner through the ZXT‐120.
Controller and Gateway Requirements
The ZXT‐120 can work with any Z‐Wave compliant controller or gateway supporting the following Z‐Wave commands.
- Configuration Command Class
- Multilevel Sensor Command Class
- Thermostat Command Class
Thermostat Mode Command Class
Thermostat Fan Mode Command Class
Thermostat Set‐point Command Class
Built‐in IR code library
The Built‐in IR code library supports most of the popular air
conditioner brands in the market. Z‐Wave gateway and controller does not need to have any IR control code knowledge. User can use Z‐
Wave controller or gateway to select the IR code according to the ZXT‐
120 code list separately provided through Z‐Wave configuration command.
4
Glossary
Device or
Node
Inclusion
Exclusion
Remove
Z‐Wave
Network
Primary
Controller
Secondary
Controller
Inclusion
Controller
Devices and nodes are all terms to describe an individual Z‐Wave device. These are all interchangeable when setting up your Z‐Wave network.
Add a Z‐Wave device to the network.
Delete a Z‐Wave device from the network.
To take a device out of a group, scene or association group while that device still exists in the same Z‐Wave network.
A collection of Z‐Wave devices is controlled by primary and secondary controllers operating on the same system. A Z‐Wave network has its own unique ID code so that controllers not in the network cannot control the system.
The first controller is used to set up your devices and network. Only the Primary
Controller can be used to include or delete devices from a network. It is recommended that you mark the primary controller for each network for ease in modifying your network.
A controller containing network information about other devices within the network and is used for controlling devices. Secondary controller is created from the Primary
Controller and cannot include or delete devices to the network.
A controller containing network information about other devices within the network and is used for controlling devices. Inclusion controller is created from the Primary
Controller in a SIS enabled Z‐Wave network.
Inclusion Controllers have the ability to add and remove devices from the network.
5
ZXT‐120 Operations
Before using the ZXT‐120, please read the [INSTALLATION] if you need to mount the ZXT‐120 to a wall. Power up the ZXT‐120 by the USB
Power 5Vdc or Dry battery AAA x 3pcs.
• Plug‐in 5Vdc power into the USB socket if operated at Always
Listening mode. Or
• Install 3xAAA batteries if operated at FLiRS mode.
• Please refer to the section of [MOUNTING PROCEDURE].
• Remove the battery cover on the back of your ZXT‐120 battery chassis.
• Mount the battery cover into the main unit with 2 screws.
• Check the polarity of the batteries and the "+/‐" marks inside the
battery compartment.
• Insert the batteries.
• Push the battery cover and main unit back in place.
L CAUTION (battery and power adaptor safety)
− Use new batteries of the recommended type and size only.
− Never mix used and new batteries together.
− To avoid chemical leaks, remove batteries from the ZXT‐120 if you do not intend to use the remote for an extended period of time.
− Dispose of used batteries properly; do not burn or bury them.
(Please carefully read through the following then store the manual for
future reference.)
6
Product Overview
“PROG” Button,
Learning and LED
Indication
Temperature sensor
External
IR Port top and 4-directions
USB Power
Surround IR Output for
5V DC
Figure 2 PROG Key and IR Port of ZXT-120
7
Battery chassis
Z‐Wave Remote Control
1) Select your operation mode; please refer to “Listening Mode” section.
2) Include or Exclude the unit from the existing Z‐Wave home control network with your primary controller.
‐ Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
‐
‐
When prompted by your primary controller, click once on the PROG button.
The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, please repeat the procedure.
3) User can use either primary controller or secondary controller
(should support configuration command class) to setup the ZXT‐
120 AC code by the parameter 27 (IR code number for built‐in code library), please refer to code list for the parameter value then setup your AC control code.
4) Once the configuration and setup were completed, the controller can use Z‐Wave “Thermostat commands class” to control their IR‐controlled air‐conditioner with the ZXT‐120.
5) You can record down your device code under the below table for future reference after setting up the ZXT‐120 correctly.
AC device programmed to your ZXT‐120
Code no.:
8
ZXT‐120 Information
How to get the NIF “Node Information Frame” on ZXT‐120 (Inclusion)
Step Setup Key
Press the PROG button on the
ZXT‐120
LED Indication Status on ZXT‐120
• LED flashes once then stay off
1
(ZXT‐120 will report the supported command class)
Parameter No. and Parameter Value of configuration command
Parameter
Number
25
(0x19)
26
(0x1A)
Definitions
Indicate a location for IR code learning and start learning
Learning status register
Note:
The status value 0x01 and
0x04 will be reset to 0 when the ZXT‐120 receive a get command to this parameter
Parameter Value
0‐22
(0x00 – 0x16)
0x00: Idle ‐ this IR channel is idle
(default)
0x01: OK ‐ the latest learning process successful and
completed
0x02: Learning ‐ the
ZXT‐120 is busy processing previous learning request
0x04: Failed ‐ the latest learning request failed
27
(0x1B)
IR code number for built‐in code library
Refer “Code list” for details
28
(0x1C)
32
(0x20)
External IR Emitter power level
Surround IR control
- to avoid the IR interference by disabling the surrounding IR emitter if 2
0x00: normal power mode
0xFF: high power mode (default)
0x00: disable
Surround IR Emitters
0xFF: enable
Surround IR Emitters
9
33
(0x21)
35
(0x23)
37
(0x25) air‐conditioners in a room are used
- extend the battery life by disabling the Surround IR
Emitters
(default)
AC function “SWING” control 0x00: SWING OFF
0x01: SWING AUTO
Learn location status
(Default)
Bit mask = 1, learn location has learn data. Otherwise, Bit mask = 0
See figure “Learn
location” as below
On below example, location 1, 7, 8, 12, 16 are learned data.
7 6 5 4 3 2 1 0
1 0 0 0 0 0 1 0 Bit Mask Byte 1
Location 0‐7
7
0
6
0
5
0
4
1
3 2 1 0
0 0 0 1
Bit Mask Byte 2
Location 8‐15
7
0
6
0
5
0
4
0
3 2 1 0
0 0 0 1
Bit Mask Byte 3
Location 16‐23
7 6 5 4 3 2 1 0
0 0 0 0 0 0 0 0
Bit Mask Byte 4
[Reseved]
Figure: Learn location
Sensor temperature Temperature offset
compensation
value.
(This parameter is used to compensate the temperature error at temperature sensor)
Formula:
Display temperature
= sensor reading value + offset value
(unit = degree C)
0x00 = 0
0x01 = 1 o o
C (Default)
0x02 = 2
0x03 = 3 o o
C
C
0x04 = 4 o
C
0x05 = 5 o
C
C
10
0xFF = ‐1
0xFE = ‐2
0xFD = ‐3
0xFC = ‐4 o o
C o o
C
C
0xFB = ‐5 o
C
C
L Mapping Information
Parameter Table
− BASIC Set Value 0x00 will map to Thermostat mode Off 0x00.
− BASIC set Value 0xFF will map to Thermostat mode Resume 0x05.
Listening Mode Change (default mode is FLiRS)
ZXT‐120 can be configured as either “Frequently Listening Routing
Slaves” (FLiRS) or “Always Listening” node after exclusion process.
FLiRS node type is targeted for battery operated applications and it will enter sleep mode frequently in order to conserve battery
consumption.
Always Listening node type is targeted for the needs of required a fast
response application.
Important:
It is not allowed to changing ZXT‐120 operation mode without exclusion process (do not change ZXT‐120 operation mode while ZXT‐
120 is included in a network).
How to switch ZXT‐120 listening mode from “Always Listening" to
“FLiRS" (or vice verse)
Step
1
2
Setup Key
Press and hold the PROG button on the ZXT‐120 for around 5 seconds
Release the button and then press the PROG button 3 times within 2 seconds
LED Indication Status on ZXT‐120
• LED stay off
• LED flashes twice then stay off
(ZXT‐120 set in FLiRS mode)
11
OR
• LED flashes four times then stay off
(ZXT‐120 set in
Always Listening mode)
IR Code Selection
ZXT‐120 is with built‐in IR AC code library, user may select the IR code
using Configuration Command Class.
Step Setup Key
LED Indication Status on ZXT‐120
‐
1
2
3
4
After included ZXT‐120 to Z‐Wave controller or Gateway, go to device setup for configuration on gateway or controller.
Input parameter number “27” and parameter value (please look up the code list of ZXT‐120 according to your AC brand). Then complete the configuration process.
Press the PROG button on the ZXT‐
120. (this step apply when using
ZRC‐100 or other portable controller for set up, if using gateway, user can skip this step)
Go back to the control page of ZXT‐
120 on the gateway and try the function such as (cool, temperature set).
If the air conditioner does not respond to the command you set on
Gateway (Cool, Heat, Auto,
Temperature set etc.), repeat step 2 and 3 to select the next code on code list.
‐
• LED flashes once when ZXT‐120 receives the configuration setting
• LED flashes once every time it receives a command from gateway
12
L Important Information
− Different brand or model of air conditioner has different function. For example, some air conditioner only support temperature set from 18 o
C‐30 o
C, if user set 17
o
C on gateway,
ZXT‐120 will not respond.
− There are more than 1 code for each brand, some does not support heat, if user selected a code that does not support heat but the original air conditioner supports heat function, please continue to try next code until the correct one is selected.
− If none of the code works on the target air conditioner, or the air conditioner brand is not shown on the code list, please select code “000” for IR code learning (refer to instruction of
IR Code Learning)
IR Code Learning
In case none of the code on the code list works for the targeted air conditioner, user can use IR code learning function using configuration
according to below steps:
Step
1
Setup Key
LED Indication Status on ZXT‐120
• LED flashes once when ZXT‐120 receives the configuration setting
2
3
Go to configuration setting page on the gateway or ZRC‐100 and input parameter number “27” and parameter value “000” to select the dedicated AC code number “000” for learning.
Look up below mapping table (value
0‐22) for learning, and decide the IR setting you intent to learn next.
For example “22°C, cool” which matches value “5” (IR code to be learnt will locate at “5” in ZXT‐120).
Set your original air conditioner remote at “22°C, cool” and turn it off. (Besides temperature and mode, you may set other desired settings, such as Fan, Swing etc.)
Go to configuration setting page on the gateway or ZRC‐100 and input parameter number “25” and
‐
‐
13
4 parameter value “5” (in this case).
Press the PROG button on the ZXT‐
120. (this step apply when using
ZRC‐100 or other portable controller for set up, if using gateway, user can skip this step)
Aim the original air conditioner remote at ZXT‐120 according to below position within 1‐3 inches
• LED flashes once when ZXT‐120 receives the configuration setting
• ZXT‐120 is ready to learn
LED flashes twice if learning is successful.
LED flashes 6 times if it’s failed.
5
Press “power on” button on the original air conditioner remote.
If the learning is failed, repeat step 3 to step 5.
To learn next IR code, repeat step 2 to step 5.
L When you encounter problem, check followings:
− Make sure your original remote is switched to power off.
− Press the key on original remote before learning mode timeout.
− Keep away from incandescent light and direct sunlight during learning.
− Make sure IR Transmitter of your original remote alight with learning diode of ZXT‐120, you may also slight adjust closer or further away the distance of two devices. Some of remotes the IR transmitter in hidden behind lens and may not installed center of remote.
− Make sure the power is good on both devices, especially the original remote. Use fresh batteries.
14
IR Learning Mapping Table (Parameter number 25)
Parameter Value
(Location)
Thermostat command
& IR setting
0 OFF
18
19
20
21
22
13
14
15
16
17
8
9
10
11
12
3
4
5
1
2
6
7
20°C heat
21°C heat
22°C heat
23°C heat
24°C heat
25° C heat
26°C heat
27°C heat
28°C heat
Dry mode
ON (resume)
19°C cool
20°C cool
21°C cool
22°C cool
23°C cool
24°C cool
25°C cool
26°C cool
27°C cool
28°C cool
19°C heat
Default Heat
Default Cool
15
L Important Information
After all learning completed, user can go back to the ZXT‐120 control page on the gateway for normal operation.
− On the gateway UI, user can only use the temperature range from the mapping table, OFF, ON(RESUME), COOL, HEAT,
DRY, If user press the button of FAN, or other function on the gateway UI which is not listed in above table, ZXT‐120 will not respond.
− If user only learnt ON, OFF, or part of the settings according to the above table, ZXT‐120 will send the learnt data to the air conditioner only. For example, user only learnt ON, OFF,
22°C Cool, 24°C Heat, ZXT‐120 will not send IR data to air conditioner if user set 27°C Cool on the gateway.
− ZXT‐120 has been pre‐defined default cool at 26°C, default heat at 22°C, when user press Cool on gateway without setting temperature, ZXT‐120 will send the learnt data of 26°C
Cool to air conditioner. When user press Heat on gateway without setting temperature, ZXT‐120 will send the learnt data of 22°C Heat to air conditioner.
− There is only one code for dry mode, user can set it at any preferred temperature.
− User can still use gateway to set up scene and schedule with
ZXT‐120, for example, to have AC turn on at 23°C every day at
7pm, 25°C at 11pm. Just make sure the set code is learnt.
− The learning mapping table is for split air conditioner which remote control is with LCD display. For window type air conditioner (which remote control is without LCD display), the mapping table with temperatures do not apply, due to different type of IR control protocol. However, user may still use the OFF, or ON/RESUME, DRY key for learning. (Because the POWER key on the original remote without LCD display is toggle, user can choose either ON key, or OFF key to learn
Power key, after learning is done, press once to turn on the air conditioner if the air conditioner is OFF, press once to turn off if the air conditioner is ON)
16
Reset ZXT‐120 to factory default
Press and hold “PROG” button for 10seconds on ZXT‐120. The LED will
flash twice until reset process is completed.
Note: This reset step will not affect the operation mode of ZXT‐120, user should refer to
“
Listening Mode
"
section if you want to change the operation mode.
L Information
− If you are using Gateway or other Z‐wave controllers to operate ZXT‐120, Please follow the instruction from the gateway or other controller.
− You can check either the specifications in the manual of your
ZXT‐120 or also check online at www.remotec.com.hk for a full list of products that can be used with your ZXT‐120.
17
INSTALLATION
MOUNTING THE ZXT‐120 TO A WALL
MOUNTING LOCATION PRECAUTIONS
• Before mounting, check the material and structure of the mounting location. If the location does not have the proper material or structure, the ZXT‐120 can fall and cause injuries.
• Use commercial items that best match the wall structure and material for the screws and other fixtures.
• Do not mount near a kitchen counter, humidifier, or other location in which it can be exposed to smoke or steam. Doing so could cause a fire or electrical shock.
• Do not mount in locations with high humidity or large amounts of dust. Doing so could cause a fire or electrical shock.
• Do not mount to locations subject to high temperatures, high humidity, or exposure to water. Doing so could cause a fire or electrical shock.
• Do not mount to locations subject to large amounts of vibration, large jolts, or large forces. These could cause an injury if the ZXT‐
120 falls and breaks.
MOUNTING PROCEDURE PRECAUTIONS
• Do not modify parts or use the ZXT‐120 in ways other than its intended use. Doing so could cause the ZXT‐120 to fall and result in an injury.
• Be sure to fully check that there are no electrical wires or pipes inside the wall before mounting.
• If any of the screws are loose, the ZXT‐120 can fall and cause an injury. Do not mount the ZXT‐120 with the screws still loose.
• Check that the two screws mounted to the wall are fully inserted into the key holes of the ZXT‐120. Otherwise, the ZXT‐120 can fall and cause an injury.
• Do not mount the ZXT‐120 so that it sticks out from the wall edge.
It could get hit by people’s bodies or objects and cause an injury.
• Supplier will not be liable for any accidents or injuries that occur due to improper mounting or handling.
• When mounting, be careful not to get your fingers pinched or injure your hands.
MOUNTING PROCEDURE
The ZXT‐120 can be mounted to a wall or wooden racks using the two key holes in the bottom case.
Note 1: The reception sensitivity varies depending on the antenna direction.
18
Note 2: Before mounting to a wall, be sure to fully read the precautions.
1. Obtain two screws suitable for the wall strength and material.
The screw size is shown in the figure below.
2. The positional relationship between the ZXT‐120 key holes and the screw mounting positions are shown in the figure below.
Note 1: When mounting the screws to the wall, leave a space between the wall and screw cap as shown in the figure.
3. Insert the ZXT‐120 key holes onto the two screws mounted to the wall, and then slide downward to secure in place.
4. After securing the ZXT‐120 to the wall, connect the USB Power or batteries and IR emitter cable to the ZXT‐120.
19
Note 1: Check that the ZXT-120 is firmly secured to the wall.
Note 2: Insert USB plug or batteries and IR emitter cable so that they are firmly connected to the ZXT-120.
5. When removing the ZXT‐120 from the wall, lift up the ZXT‐120, then pull it towards you.
6. Detach the main unit from the battery chassis by move toward to top position.
20
WIRELESS INFORMATION
Wireless range:
This device has an open‐air line‐of‐sight transmission distance of 100 feet which complies with the Z‐Wave standards. Performance can vary depending on the amount of objects in between Z‐Wave devices such as walls and furniture. Every Z‐Wave device set up in your network will act as a signal repeater allowing devices to talk to each other and find alternate routes in the case of a reception dead spot.
Radio frequency limitations:
1. Each wall or object (i.e.: refrigerator, bookshelf, large TV, etc) can reduce the maximum range of 65 feet by up to 25 to 30%.
2. Plasterboard and wooden walls block less of the radio signal then concrete, brick or tile walls which will have more of an effect on signal strength.
3. Wall mounted Z‐Wave devices will also suffer a loss of range if they are housed in metal junction boxes which could also reduce the range by up to 25 to 30%.
MAINTENANCE
1 Do not expose your ZXT‐120 to dust, strong sunlight, humidity, high temperatures or mechanical shocks.
2 Do not use old and new batteries together as old batteries tend to leak.
3 Do not use corrosive or abrasive cleansers on your ZXT‐120.
4 Keep the unit dust free by wiping it with a soft, dry cloth.
5 Do not disassemble your ZXT‐120, it contains no user‐serviceable parts.
FREQUENTLY ASKED QUESTIONS
Z‐Wave Frequently Asked Questions
Q Why won’t my ZXT‐120 work with the Z‐Wave devices I purchased from another country?
A Due to different countries regulations Z‐Wave products from different regions are set to different frequencies. Before purchasing new devices make sure you have checked that the device is compatible in your region.
Q How do I know which product is compatible with my ZXT‐120?
A ZXT‐120 should work with any Z‐Wave controller or gateway that has control capability for “Thermostat” devices. You can check either the specifications in the manual of your ZXT‐120 or also check online at www.remotec.com.hk for a full list of products that can be used with your ZXT‐120. All Z‐Wave products also come with the Z‐Wave logo.
21
Q Can I use the USB port to configure ZXT‐120?
A No, the mini USB port only provides an alternative option for user to power the ZXT‐120.
Q Do I need an electrician to install Z‐Wave products in my house?
A Installation can be simple. In some cases all you need to do is mount the ZXT‐120 to a wall or wooden racks. You also can place the ZXT‐120 on the desk and power it with dry cell batteries.
Q How to select my air‐conditioner IR code from ZXT‐120?
A You should refer to the code list and look into the brand and try the code no. sequentially until you find the right code. You can record down your device code under the table for future reference after setting up the ZXT‐120 correctly.
Q ZXT‐120 is working on top and 4‐directions IR output, but there
is no response on the IR emitter socket, why?
A ZXT‐120 supports two IR power levels for the external IR emitter to avoid saturation of the IR receiver. You can set the IR output power level by the Parameter Table value (normal or high power mode) or adjust the position of your external IR emitter.
Q Can I use 2 or more ZXT‐120 in my house? What is the max. units if yes?
A Yes and it is very depend on the capability of gateway / controller.
For example, gateway can supports up to 8, 16 or 32 ZXT‐120 in a network.
Q How to avoid the IR interference if I am using 2 identical air‐ conditioners in same location but want to control them individually?
A User can disable the Surround IR Output function, connect the external IR emitter and aim it at the specific AC unit. The operating distance of external IR emitter is around 100cm (High power mode) and 50cm (Low power mode) but it is also depends on the sensitivity of the IR receiver.
External IR emitter cable
22
Q Where can I keep up to date with the latest Z‐Wave products for my house?
A You can keep up to date by visiting the www.remotec.com.hk website where we will have information and ideas for using Z‐
Wave technology.
TECHNICAL SPECIFICATIONS
Model no.
RF frequency
RF operating distance
BW8377EU (ZXT‐120EU)
BW8377AU (ZXT‐120AU)
BW8377US (ZXT‐120US)
BW8377IN (ZXT‐120IN)
868.4MHz (EU) (ZXT‐120EU)
921.4MHz (AU) (ZXT‐120AU)
908.4MHz (US) (ZXT‐120US)
865.22MHz (IN) (ZXT‐120IN) up to 80ft outdoor line of sight, in unobstructed environment
IR operating distance up to 25ft line of sight, in unobstructed environment
IR learning
Temperature
Powered by
Dimension
Weight
Max. 23 commands
Measurable range: 32 – 104 °F / 0 – 40 °C
Report resolution: 1 degree C
Operation: 0 ‐ 40°C
Storage: ‐20 ‐ 60°C
USB Power DC 5V 100mA or
Dry battery AAA x 3pcs
Dia.=70mm, T = 18mm (Main unit)
Dia.=70mm, T = 15.5mm (Battery chassis)
35g (Battery chassis excluded)
60g (Battery chassis included)
90g (Main + Battery chassis + AAA x3pcs)
Z‐Wave device type
Basic Device Class: BASIC_TYPE_ROUTING_SLAVE
Generic Device Class: GENERIC_TYPE_THERMOSTAT
Specific Device Class: SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Z‐Wave Command Class
COMMAND_CLASS_THERMOSTAT_MODE
Version Controlled Supported
Version2 NO YES
COMMAND_CLASS_THERMOSTAT_SETPOINT Version2 NO YES
COMMAND_CLASS_THERMOSTAT_FAN_MODE Version2 NO YES
23
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_BASIC
COMMAND_CLASS_VERSION
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_SWITCH_ALL
COMMAND_CLASS_MANUFACTURER_SPECIFIC
Version1 NO
Version1 NO
Version1 NO
Version1 NO
Version1 NO
Version1 NO
Version1 NO
Supported function in Thermostat Command Class
Z‐Wave command class Description
Auto/Auto Low
Thermostat Fan mode
Low
Auto High
High
Auto Medium
Thermostat Set point
Thermostat Mode
Medium
Heating
Cooling
Furnace
Dry Air
Moist Air
Auto changeover
Energy Save heating
Energy Save cooling
Away heating
Off
Heat
Cool
Auto
Auxiliary/Emergency Heat
Resume
Fan only
Furnace
YES
NO
YES
YES
NO
NO
YES
YES
YES
YES
NO
YES
NO
NO
YES
YES
YES
NO
Supported
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
24
Dry Air
Moist Air
Auto Changeover
Energy Save Heat
Energy Save Cool
AWAY
ZXT‐120 functions and Parameters summaries:
FUNCTIONS
AIR
CONDITIONER
FUNCTION
Z-WAVE COMMAND CLASS
COMMAND_CLASS_THERMOSTAT
_MODE
POWER ON
YES
NO
YES
NO
NO
NO
Z-WAVE
COMMAND
THERMOSTAT_
MODE_SET
COMMAND
PARAMETER
MODE = 5
POWER
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 0
POWER OFF
MODE
AUTO
COOL
FAN
HEAT
DRY
AUTO
Changeover
HEAT mode
Temperature
TEMPERATURE
SETTING
COOL mode
Temperature
DRY mode
Temperature
AUTO mode
Temperature
FAN SPEED FAN AUTO
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_SETPOINT
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
MODE = 3
MODE = 2
MODE = 6
MODE = 1
MODE = 8
THERMOSTAT_
SETPOINT_SET
MODE = 10
SETPOINT TYPE =
1,
TEMPERATURE
VALUE
SETPOINT TYPE =
2,
TEMPERATURE
VALUE
SETPOINT TYPE =
8,
TEMPERATURE
VALUE
SETPOINT TYPE =
10,
TEMPERATURE
VALUE
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 0
25
FAN LOW (1/3)
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
THERMOSTAT_
FAN_MODE_SE
T
THERMOSTAT_
FAN_MODE_SE
T
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 0, 2, or
4
FAN MODE = 1
FAN MODE = 1
SWING
IR CODE SETUP
IR
TRANSMISSION
POWER LEVEL
FRONT IR
TRANSMISSION
CONTROL
FAN MID (2/3)
FAN HIGH (3/3)
SWING ON/
SWING AUTO
SWING OFF
NORMAL
POWER LEVEL
HIGH POWER
LEVEL
DISABLE
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
THERMOSTAT_
FAN_MODE_SE
T
THERMOSTAT_
FAN_MODE_SE
T
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 5
FAN MODE = 3
FAN MODE = 3
CONFIGURATIO
N_SET
PARAMETER NO. =
33
SIZE = 1
CONFIGURATIO
N_SET
VALUE = 1
PARAMETER NO. =
33
SIZE = 1,
CONFIGURATIO
N_SET
VALUE = 0
PARAMETER NO. =
27
SIZE = 2,
CONFIGURATIO
N_SET
VALUE = (CODE#)
PARAMETER NO. =
28
SIZE = 1,
CONFIGURATIO
N_SET
VALUE = 0
PARAMETER NO. =
28
SIZE = 1,
CONFIGURATIO
N_SET
VALUE = 0xFF
PARAMETER NO. =
32
SIZE = 1,
26
BATTERY
LEVEL
VERSION
MANUF'ER
SPECIFIC
TEMPERATURE
SENSOR
ENABLE
COMMAND_CLASS_CONFIGURATI
ON
CONFIGURATIO
N_SET
VALUE = 0
PARAMETER NO. =
32
SIZE = 1,
VALUE = 0xFF
COMMAND_CLASS_MANUFACTUR
ER_SPECIFIC
COMMAND_CLASS_SENSOR_MUL
TILEVEL
MANUFACTURE
R_SPECIFIC_GE
T
SENSOR_MULTI
LEVEL_GET
27
CHECKING ACCESSORIES
After opening the cover of the packing box, check that the following accessories are included.
• ZXT‐120 (Z‐Wave‐to‐AC IR Extender)
• Screws (bottom cover) x 2pcs
• ZXT‐120 User Manual (download from our website)
• AC Code List (download from our website)
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
WARNINGS
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
‐ RISK OF FIRE
‐ RISK OF ELECTRICAL SHOCK
‐ RISK OF BURNS
‐ The socket‐outlet shall be installed near the equipment and shall be easily accessible.
‐ Use only power supplies listed in the user instructions.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for
information regarding the collection systems available.
CAUTION
‐ RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT
TYPE.
‐ DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
28
WARRANTY
ONE‐YEAR LIMITED WARRANTY: Remotec warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the original date of purchase from the distributor or dealer.
REMOTEC shall not be liable for: z damages caused by defective devices for indirect, incidental, special, consequential or punitive damages, including, inter alia, loss of profits, savings, data, loss of benefits, claims by third parties and any property damage or personal injuries arising from or related to the use of the device. z Service trips to provide instruction on product use. z Shipping costs for replacement products.
This warranty is limited to the repair or replacement of this product only, if the purchase date cannot be substantiated, the warranty period will begin on the date of manufacture as indicated on this product. All warranty claims must be made to Remotec appointed distributors or dealers during the applicable warranty period. This warranty gives you specific legal right and you may also have other rights which vary in each country.
www.remotec.com.hk
Printed in China F820‐8377‐0000
29