Raritan | PX-1000 Series | User manual | to Dominion-PX frequently asked questions

Add to my manuals
7 Pages

advertisement

Raritan | PX-1000 Series | User manual | to Dominion-PX frequently asked questions | Manualzz

Dominion

®

PX

®

Question

General Questions

Answer

What is Dominion PX (PX)? The Dominion PX is an intelligent rack Power Distribution Unit (iPDU) that allows users to monitor power and environmental conditions such as temperature and humidity.

It can be used as a standalone power distribution unit, or integrated with Raritan’s

Power IQ

®

energy management software, KVM switches and CommandCenter

®

Secure Gateway (CC-SG).

Is Raritan new to the rack power distribution unit market?

No. On the contrary, Raritan has been in the rack power distribution business since 2003.

Can the PX be used as a stand-alone device?

Does PX work with Raritan

CommandCenter Secure

Gateway?

’s

Yes. It can be used either as a stand-alone power management unit or it can be integrated with Raritan ’s access and management products, including Power IQ and CommandCenter Secure Gateway.

Yes. PX is deployable as part of an enterprise-wide management solution with

Raritan ’s CommandCenter Secure Gateway. Hundreds of PX units can be managed via CommandCenter Secure Gateway directly or through Dominion SX

(serial only), KX and Paragon

®

II.

How can I consolidate the sites where I have a PX installed? What if I have other

PDU brands as well?

The Raritan Power IQ software manages rack PDUs, providing a single Web interface for outlet, rack and data center power, current, voltage, temperature and humidity monitoring and remote outlet switching. Power IQ manages the PX and third-party rack PDUs, and can also be integrated with data warehouse and enterprise reporting systems.

Raritan ’s CommandCenter Secure Gateway is designed specifically to provide centralized management. It is the ideal solution if you are looking to consolidate management of devices such as PX with other Raritan network-based products.

For IP-based consolidation, SNMP or external Command Line Interface (CLI), scripting may be considered.

How does the PX differ from

Raritan Remote Power

Control (RPC) and PM units?

PX offers additional features such as outlet-level power monitoring, access via both Ethernet (TCP IP) and serial for remote access, an intuitive browser-based

GUI, support for optional temperature and humidity sensors and other flexible access methods.

Can the firmware on the PX be upgraded?

Yes. The architecture of the PX enables easy firmware upgrades via updates from

Raritan.com so you can have the latest functionality without having to buy new hardware.

© 2012 Raritan Inc. Page 1 of 7 V1121 R1 April, 2012

Dominion ® PX

® – Frequently Asked Questions

Question

Are updates to PX software free?

Are there any software requirements for PCs connected to PX?

Will there be other models in the PX family?

Can I get custom configurations of the PX?

Hardware

In what form factors can I get the PX?

In what rack positions can

Zero U PX models be mounted?

Does PX include the rack mount kit or is there an extra charge for this option?

Does the PX have circuitlevel fuses?

Is it possible to “daisy chain”

PX PDUs?

Answer

Yes. Currently all firmware upgrades are free.

For access using a Web browser, the PX does not require any software to be loaded on the client; however, the browser does have to be Java

TM

-enabled. When using SSH/TELNET, the customer has to provide an SSH/TELNET client. In some operating systems, like Linux

®

, an SSH client is included in the distribution. Also,

OpenSSH.org

has an SSH client that can be downloaded free of charge. PuTTY is one of the most popular SSH clients for Windows

®

and can also be downloaded free from the Internet.

Yes. There are currently hundreds of PX models. Additional models of the PX family are introduced on a regular basis.

Yes. Note that lead times will vary depending on the level of customization required.

The PX comes in two form factors:

 Horizontal rack mount – 1U, 2U models

 Vertical mount – Zero U models

All five mounting positions are supported with APC racks.

The PX units come standard with a complete ready-to-install rack mount kit.

PX uses UL 489 circuit breakers for branch circuit protection in North America and most of the world. Some PX models, however, have been made available with outlet fuses at customers’ requests, typically outside North America.

Up to four PXs may be cascaded. One PX rack PDU can access via one Ethernet connection up to three additional PX rack PDUs (a total of up to four, one master and three slaves) via cascading PX USB ports (USB-A (host) to USB-B (device)).

Each PX requires its own IP address so that functions for all PX units are individually supported, e.g., ping, SNMP, alerts, firmware upgrades, HTTP/S access, SSH, etc.

© 2012 Raritan Inc. Page 2 of 7 V1121 R1 April, 2012

Dominion ® PX

® – Frequently Asked Questions

Question

Why aren ’t there circuit breakers on PX models that are 20 amps and below?

Some PDUs lose all the power if one or more circuit breakers are tripped. Is this true for PX?

What happens to the servers powered by the PX if the electronics of the PX malfunction? Will the servers lose power?

By factory default are the outlets on a PX enabled (i.e., on) or disabled (i.e., off)?

For switched models, why is the LED by each outlet on a

PX GREEN when the outlet is OFF/Disabled and RED when it is ON/Enabled?

Can I use the Ethernet and the serial ports on the PX at the same time?

Answer

A 20 amp or less rack PDU (1- or 3-phase) is always connected to a branch circuit that is protected by a 20 amp circuit breaker in a panelboard (aka building PDU,

RPP). This breaker trips when the total of all the outlets in a rack PDU exceeds 20 amps.

North American 208V 3-phase PDUs have the outlets divided into 3 banks. Each bank is wired across two phase legs (L1-L2, L2-L3, L3-L1). NEC requires that if a

PDU input is rated greater than 20 amps, then a 2-pole 20 amp circuit breaker must be used to protect each bank of outlets. When each bank draws 20 amps, the total amps on each input line is 35 amps.

In general, we design PDUs using the following rules:

 If a PDU is rated 20 amps or less (or 16 amps internationally), then no circuit breakers are used (per UL 60950-1).

 If a PDU is rated greater than 20 amps (or greater than 16 amps internationally), then outlets are divided into banks and each bank is overcurrent protected by a 20 amp (or 16 amp) circuit breaker.

No. In PX PDUs, the control circuitry is in front of all circuit breakers, so tripping any one or more breakers has no affect on power delivered to the controller. In PX

3-phase PDUs, power for the controller is derived from all 3 phases, so even loss of any 2 of 3 phases will not affect power delivered to the controller.

No. The PX is designed to continue to run with NO change to the power outlets in the case of an electronics malfunction. The outlets that are on will remain on and the outlets that are off will remain off.

By factory default all the outlets are enabled always on.

– that is to say, they are turned “on.”

For models without switching, e.g., PX-4000 and PX-1000 series, all outlets are

In the world of power, RED indicates that the power is running (outlet is “live” or

“hot”) to that outlet. GREEN indicates it is NOT running or that the outlet is not enabled. For PX models without switching, all outlets are always enabled.

Yes. Just ensure that both interfaces are enabled and configured.

Can I set the Ethernet port on the PX to run at 100Mbps full-duplex?

Yes.

Is the Ethernet port on the PX unit 10/100Mbps autosensing?

Yes. But it can also be set to run at 100Mbps.

© 2012 Raritan Inc. Page 3 of 7 V1121 R1 April, 2012

Dominion ® PX

® – Frequently Asked Questions

Question

What is the purpose of the

RJ-12 connector on the front panel of the PX units?

Are environmental sensors available with the Dominion

PX?

Answer

This connector (labeled “feature” on some models and “sensor” on others) is for adding Raritan’s optional but fully integrated environmental monitoring sensors.

Yes. Optional but fully integrated environmental sensors are available.

What are the clicks from the

PX, circuit breakers tripping?

I moved my PX to a new rack and now I can't access it.

What happened?

PX ships from the factory with Dynamic Host Configuration Protocol (DHCP) enabled. DHCP is a protocol used by networked devices (clients) to obtain various parameters necessary for the clients to operate in an Internet Protocol (IP) network. DHCP automates the assignment of IP addresses, subnet masks, default gateway and other IP parameters. If a PX is moved to a new location, with DHCP still enabled (the factory default setting), DHCP will again automatically assign the

PX an IP address, subnet mask, etc. If the IT administrator tries to access the PX using the IP address assigned at the previous location, the PX will not respond because the PX now has a different IP address. When moving a PX, IT administrators should 1) leave DHCP enabled and then access the serial port of the PX to find the new IP address (see Quick Start Guide), 2) disable DHCP prior to moving the PX so it retains the same IP address or 3) if possible, configure

DHCP to assign a specific IP address to the PX.

Features

Clicks from a PX that supports switching are typically relays opening and closing which is normal. When a circuit breaker (CB) trips, the LED will blink yellow because internal relay boards will not be receiving voltage from the tripped CBs.

Also, the CB handle will be physically in the “off” position. Using the LED panel on the PDU to view outlet voltages (press up/down keys together to toggle from current readings to voltage readings), the voltages will be zero or near zero if the

CBs have tripped.

Does the PX support outlet- level monitoring?

Yes, for outlet metered, outlet switched and outlet metered only models. Outlet monitoring is supported when using the GUI (HTML interface) and SNMP (via the

Ethernet port) and via the Command Line Interface (CLI) – Ethernet or serial.

Where is power measured on

PX 3-phase models?

For all PX models, reporting occurs at three levels: 1) phase level,

2) PDU level and 3) circuit breaker level. For PX-5000 and PX-4000 models, power is also reported at the outlet level.

Yes, Raritan’s Power IQ supports outlet grouping associations across PDUs. Can I cluster multiple PXs in a rack or data center using

TCP IP?

Yes, SSH connections are supported. Can I use SSH to connect to the PX?

Does the PX support

TELNET?

Yes, PX supports TELNET, but it is disabled by factory default.

© 2012 Raritan Inc. Page 4 of 7 V1121 R1 April, 2012

Dominion ® PX

® – Frequently Asked Questions

Question

Why is TELNET disabled by default on the PX?

Answer

PX supports enabling of the TELNET daemon. However, because TELNET sends all information “in the clear,” enabling TELNET is at the customer’s own discretion.

Raritan strongly suggests the use of SSH as a safer alternative to TELNET, since all data is encrypted, including the login sequence.

Does the PX support Network

Time Protocol (NTP) servers?

Yes. Up to two external NTP servers can be supported by the PX.

Does the PX support DNS servers?

Does the PX support

Dynamic DNS?

Yes. Up to two DNS servers can be supported by the PX.

Yes.

Does the PX support a fullfeatured Command Line

Interface (CLI) for advanced applications using external scripting?

Does PX support SNMP

TRAPs, SETs and GETs?

Does PX support syslog?

Yes. The SMASH CLP-based CLI allows management and configuration of very granular features, like per-outlet IP access control list (ACL). On all models with a model number which looks like PX2-nnnn (where nnnn are numbers), the CLI is

JSON-RPC.

Yes. PX supports SNMP TRAPs, SETs and GETs via an Enterprise MIB. Dominion

PX supports SNMP v1, v2 and v3.

Yes. PX supports syslog – to primary and secondary servers.

Yes. Does the PX support SMTP

(e-mail) alerts and notification?

Can an SMTP server that requires a username and password for connection be used for the e-mail notifications from the PX?

Yes. The PX supports SMTP server authentication.

Which ports need to be open on the corporate firewall for a secure console session using

PX?

Port 443 (for https); optionally, port 80 (http) for user sessions. When using SSH, port 22 needs to be open. For TELNET, port 23 needs to be open.

Yes, but only if you use the Dominion SX or other console server that supports this capability.

Can I get the buffered offline data from the serial port of the PX?

If I am using the Ethernet interface as the primary means of power monitoring and control, does PX support local (direct) port access for

“crash-cart” applications in a data center using a terminal

(VT100/equivalent)?

Yes, the PX supports local port access. Default parameters are 9600-N-8-1. The local port on the PX is an RJ-45 female. An RJ-45 male to DB9F (female) nullmodem cable is provided with each PX for setup and crash-cart applications.

Models that have part number PX2-nnnn (where nnnn are numbers), the default speed for the port is 115.2Kbps (N-8-1), and the serial port on the units is a DB9M

(male).

© 2012 Raritan Inc. Page 5 of 7 V1121 R1 April, 2012

Dominion ® PX

® – Frequently Asked Questions

Question

How can I restore the PX to factory default setting?

Answer

A hardware reset button (recessed pinhole) is provided to allow access to a software (CLI command) mode to restore the unit to factory default. It can also be restored to factory default from the HTML GUI using a Web browser. For safety and security reasons it is not possible to restore the unit to factory default otherwise.

Security

What level of encryption does the PX support?

The PX hardware supports up to 256-bit AES encryption DPC and DPX models, and all models with a model number PX-nnnn (e.g., PX-5000, PX-4000, PX-

3000). Models with model number PX2-nnnn support AES via software.

What security is available to determine what is happening at a rack or in the data center?

How do I get access to the operating system of the PX?

I have lost my Admin password to the PX. Is there a backdoor or secret password?

Does the PX support strong passwords like other Raritan products?

Can I use PX over a VPN connection?

PX supports a webcam via USB ports for cabinet and data center security. The webcam may stream video or a snapshot may be triggered by optional contact closure (DPX-CC@-TR) or other sensors such as temperature, humidity, airflow and air pressure. (Tested with Logitech 9000 Pro webcam)

PX is a secure appliance. Therefore, NO access is possible to the operating system.

For security reasons, PX does not have any “backdoor” usernames or passwords.

Restoring the unit to factory default will reset it to the factory default username and password.

Yes. Full support is provided for strong password options, for example, lockout on retries, password length and character control and a host of other options.

Yes, PX fits into most network configurations utilizing TCP/IP. Set up the VPN

(typically IPSec) connection, then start the Web browser and enter the URL for the

PX unit, or use SSH or Telnet. The session to the PX runs transparently over the

VPN tunnel.

Yes. Does the PX have a built-in firewall?

Does the PX support IP

Access Control Lists (ACL)?

Using the CLI, can per outlet

IP access control list (ACL) be enabled?

What authentication mechanisms does the PX support?

Can the PX support authorization at a per-port level?

Yes.

Yes.

DPC and DPX models, and all models with a model number PX-nnnn (e.g.,

PX-5000, PX-4000, PX-3000) support local database, RADIUS, LDAP/S and

Active Directory

®

.

Models with model number PX2-nnnn support AES via software, local database,

LDAP/S and Active Directory.

Yes. PX can support authorization at a per-port level – via the local database,

RADIUS, LDAP/S and Active Directory.

© 2012 Raritan Inc. Page 6 of 7 V1121 R1 April, 2012

Dominion ® PX

® – Frequently Asked Questions

Question

When using SSL, does the

PX support SSL server certificates?

Answer

Yes.

Can the PX be used to generate an SSL Client

Certificate Request (CSR) for a Certificate Authority (CA)?

Yes.

Interoperability

With which release of the

Dominion SX can I do full power control from the HTML

GUI?

Dominion SX release 3.1 and above fully supports the PX.

For control via the serial port of the PX, CommandCenter Secure Gateway release

3.1.1 or higher is required.

With which release of the

CommandCenter Secure

Gateway is the PX first supported?

Can I use the SX

PowerBoard applet

(supported by SX firmware releases through 2.5 only) to control a PX with a Dominion

SX running 3.0 firmware?

What is the maximum number of PX units controllable through a

Dominion SX?

Does the Dominion KX support the PX?

Regulatory Compliance

Is the PX RoHS compliant?

No. The old PowerBoard applet is not compatible with Dominion SX 3.0 and newer releases. Upgrade the Dominion SX unit to release 3.1 or higher for support of the PX when the Dominion SX is used in a stand-alone mode to manage the

PX. When using the CommandCenter Secure Gateway with a Dominion SX, CC-

SG can be used to provide the On/Off/Recycle commands to the PX via the

Dominion SX.

This is limited only by the maximum number of serial ports on a Dominion SX. For example, a 16-port Dominion SX unit can be used to control 16 PX units, and a 32port Dominion SX unit can be used to manage 32 PX units. See the PX User

Guide for more details on interoperability and maximum units supported by other

Dominion series products.

Yes. See the PX User Guide for more details on interoperability and maximum units supported by other Dominion series products.

Yes. The PX is RoHS compliant.

© 2012 Raritan Inc. Page 7 of 7 V1121 R1 April, 2012

advertisement