Air King AX SERIES Service manual
Add to my manuals
43 Pages
Air King AX SERIES is a powerful and efficient air conditioner with a range of features to keep you comfortable all year round. With its cooling, heating, and dehumidifying modes, the system can maintain your desired temperature and humidity levels, whether you're trying to beat the summer heat or warm up on a cold winter day. The fan mode provides air circulation without cooling or heating, while the auto mode automatically adjusts the system's operation based on the ambient temperature.
advertisement
▼
Scroll to page 2
of 43
SERVICE MANUAL KING SERIES ASH-18AK, ASH-24AK 1 Summary and features 18 Outdoor unit: Model ASH-18AK ASH-24AK 24 Outdoor unit: Remarks 1Ph 220~240V 50Hz R410a 22 Technical specifications ASH-24AK ASH-18AK Model . . COOLING Function Rated Voltage Rated Frequency HEATING COOLING HEATING 220-240V~ 220-240V~ 50Hz 50Hz 18000 19500 22000 23200 Power Input (W) 1640 1670 2120 2120 Rated Input (W) 2500 2550 3000 3000 Rated Current (A) 10.9 11.1 13 13 Total Capacity (Btu/h) Air Flow Volume (m3/h) (H/M/L)** Dehumidifying Volume (l/h) EER / C.O.P (W/W) Energy Class Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) . 830/670/600 830/670/620 3 4 3.21 3.01 A B ASH-18AK . ASH-24AK 1200/1050/900 1200/1050/950 20 / 1 0.4 Cross flow fan – 1 φ96 X 797 20 / 1 0.4 Cross flow fan – 1 φ96 X 797 Aluminum fin-copper tube Aluminum fin-copper tube Φ7 2-1.6 Φ7 2.5-1.6 785X340.51X25.4 785X340.51X25.4 MP35XX 2.5 PCB 3.15A Transformer 0.2A MP35XX 2.5 PCB 3.15A Transformer 0.2A 48/45/42/38 48/45/42/39 58/55/52/48 58/55/52/49 1020X228X310 1020X228X310 Dimension of Package(W/H/D)(mm) 1078X390X325 1078X390X325 Net Weight /Gross Weight (kg) 14/19 15/20 Output of Fan Motor (w) Input of Heater (w) Fan Motor Capacitor (uF) Fan Motor RLA(A) Fan Type-Piece Diameter-Length (mm) Evaporator Indoor Pipe Diameter (mm) unit Row-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level dB (A) (H/M/L) Sound Power Level dB (A) (H/M/L)*** Dimension (W/H/D) ( mm) Model of Outdoor Unit Com pres s or Manufacturer/trademark Com pres s or Model Com pres s or Type L.R.A. (A) Com pres s or RLA(A) Com pres s or Power Input(W) Overload Protector Throttling Method Starting Method Working Tem p Range (℃) Condens er Pipe Diameter (m m) Rows -Fin Gap(m m ) Coil length(l) x height(H) x coil width(L) Fan Motor Speed (rpm ) (H/M/L) Outdoor Output of Fan Motor (W) Fan Motor RLA(A) unit Fan Motor Capacitor (uF) Air Flow Volum e of Outdoor Unit Fan Type-Piece Fan Diameter (m m) Defrosting Method Clim ate Type Is olation Mois ture Protection Perm is s ible Exces s ive Operating Pres sure for the Dis charge Side(MPa) Perm is s ible Exces s ive Operating Pres sure for the Suction Side(MPa) Sound Pres s ure Level dB (A) (H/M/L) Sound Power Level dB (A) (H/M/L) Dim ens ion (W/H/D) (mm ) Dim ens ion of Package (L/W/H)(m m) Net Weight /Gros s Weight (kg) Refrigerant Charge (kg) Length (m ) Gas additional charge(g/m ) Connecti Outer Liquid Pipe (mm ) on Pipe Diam eter Gas Pipe (m m) Height (m) Max Length (m ) Dis tance ASH-18AK . Shanghai Hitachi Electrical Appliances Co,Ltd./Highly ASH210SV-C8LU rotary com pres s or 40 7.5 1725 ASH-24AK . Shanghai Hitachi Electrical Appliances Co,Ltd./Highly ASH264SV-C8LU rotary com pres s or 60 10.3 2215 Capillary Capacitor -7 ℃≤T≤43 ℃ Aluminum fin-copper tube 7 2-1.4 806×660×25.4 860 48 0.62 3.5 2790m3/h Axial fan –1 Φ473 Auto defros t T1 I IP24 Capillary Capacitor -7 ℃≤T≤43 ℃ Aluminum fin-copper tube Φ9.52 2-1.4 804X660X44 780 68 1.2 2.5 3400m3/h Axial fan –1 Φ472 Auto defros t T1 I IP24 3.8 3.8 1.2 1.2 56/54/52 66/64/62 913X680X378 994X720X428 46/50 R410/1.6 4 50 Φ6 Φ12 10 15 56/54/52 66/64/62 950X700X412 1100X755X450 59/64 R410/1.85 4 50 Φ9.52 Φ16 10 15 The above data is subject to change without notice. Please refer to the nameplate of the unit. 3 Part name Air in Front Panel Manual switch Indoor unit Filter Guide louver Air out Indicator light Wrapping Tape Wall Pipe Remote control window Wireless remote control Heat Cooling Run Air in Connection pipe Outdoor unit Drainage hose Air out 4 Outline and installation dimension Outline and installation dimensions of indoor unit H Air inlet D W Tube exit Wall-Mounting Plate: Rear View 18/24 Ceiling Left Right Wall-Mounting Plate Model ASH-18AK ASH-24AK W(㎜) H(㎜) D(㎜) 1020 228 310 Outline and installation dimensions of outdoor unit ASH-18AK 913 342 680 378 Unit:mm 550 Bolt Nut Wrench ASH-24AK 378 700 950 572 Unit:mm over over over over Bolt Nut Wrench 5 Electrical circuit diagram ASH-18AK ASH-24AK These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit. 6 Manual of functions of remote controller and operation method Manual 1 of functions of remote controller 6.1.1 Temperature parameter The room setting temperature(Tpreset) The room ambient temperature (Tamb) 6.1.2Basic Functions Once energized, the compressor should in no way be restarted unless after 3-minute time interval at least. For the first energization, the compressor will be started without 3-minute lag. The compressor, once started,will not be stopped within 6 minutes with the change of room temperature. Cooling Mode Cooling Conditions and Process When T amb.≥Tpreset +1℃, the unit will run under cooling mode, in which case the compressor and outdoor fan will start and the indoor fan will run at setting speed. When T amb.≤Tpreset -1℃, the compressor and the outdoor fan will stop, the indoor fan will run at setting speed. When Tpreset -1℃<T amb.< Tpreset +1℃, the unit will maintain its original operating status. Under this mode, the switchover valve will not be powered on, and the setting temperature range is16 ~30 . Tpreset +1℃ Start cooling Tamb Original operating status Tpreset -1℃ ≥6 min. ≥3 min. ≥6 min. Stop cooling Compressor Outdoor fan Indoor fan Preset speed 6.1.2.1.3 Protection Run Stop Antifreeze Protection If it is detected that the system is under antifreeze protection, the compressor and outdoor fan will be stopped, and the indoor fan will run at setting speed. When antifreeze protection is released and the compressor has stopped for 3 minutes, the unit will resume its original operating status. During antifreeze protection 3 min. Compressor Outdoor fan Preset speed Indoor fan 6.1.2.2 DRY Modes Run Stop 6.1.2.2 .1 The conditions and process of DRY When T amb. > T preset+2℃, the unit will run under DRY cooling mode, in which case the compressor and outdoor fan will be started and the indoor fan will run at low speed. When Tpreset -2℃≤T amb.≤Tpreset +2℃, the unit will run under DRY mode, in which case the indoor fan will keep run at low speed, the compressor and the outdoor fan will be stopped after 6 minutes . After 4 minutes,the compressor and the outdoor fan will be restarted. The dehumidifying process is so repeated in cycle. When Tamb.< Tpreset-2℃, the compressor and outdoor fan will be stopped, the indoor fan will run at low speed. Under this mode, the switchover valve will not be powered on, and the setting temperature range is16 ~30 . . Tpreset +2℃ Cooling Tamb Dry Tpreset -2℃ 6 min. 4 min. Stop 6 min. 4 min. Compressor Outdoor fan Indoor fan low speed Run Stop 6.1.2.2.3 Protection Antifreeze Protection Upon meeting the cooling condition, if it is detected that the system is under antifreeze protection, the compressor and outdoor fan will be stopped,and the indoor fan will run at low speed. When antifreeze protection is released and the compressor has stopped for 3 minutes, the complete unit will resume its original operating status. Upon meeting the dehumidify condition, if it is detected that the system is under antifreeze protection, the com -pressor and outdoor fan will be stopped,and the indoor fan will run at low speed. When antifreeze protection is released and the compressor has stopped for 4 minutes, the complete unit will resume its original operating status. 6.1.2.3 HEAT Mode (there is no this mode for cooling only unit) 6.1.2.3 .1The conditions and process of heating When Tamb Tset +2 ,the system enters heating running, in this case, the reversal valve, compressor, outer fan enter simultaneously running.The indoor fan will delay at most for 2min to run. When Tamb Tset +4 ,the compressor and outdoor fan will stop, but the reversal valve is still with power on, the indoor unit will run at setting fan speed for 60s then will stop . When Tset +2 <Tamb < Tset +4 ,the unit will maintain its original operating status. Under this mode, the switchover valve will be powered on, and the setting temperature range is16 ~30 . Stop heating Tset Original running state Tset Start heating Tamb. 6Min. 3Min. 6Min. Compressor Outer fan Inner fan 2Min. Setting fan speed 2Min. Setting fan speed Reversal valve Running 6.1.2.3.3 Conditions and processes of defrost Stop This unit adopt intelligent defrosting,it can defrost according to the frosting conditions,dual 8 display H1 6.1.2.3.4 Protection High Temp. Protection If it is detected that the evaporator tube temperature is too high, the outdoor fan will be stopped. When the tube temperature resumes to normal, the outdoor fan will be restarted. Noise Silencing Protection: If the unit is stopped by pressing ON/OFF, the reversal valve will be stopped after 2-minute lag; or 2 minutes will be delayed upon mode switching. 6.1.2.4 Fan mode Under FAN mode, only the indoor fan runs at setting speed.The RUN indicator will be bright. Double 8 module indicator will display the setting temperature. When stand by, the power indicator is bright but the unit does not run. 6.1.2.5 Auto Mode Under this mode, the system will automatically select its run mode (cool, dehumidify, heat or fan) with the change of ambient temperature. For protection function, same as under cooling and heating mode. 3.Other controls 1. Memory function Memory contents: Mode, up and down swing, Light, Setting temp., Setting fan speed, Ordinary setting Fahrenheit/Centigrade, after powered off, and powered on, it will run at the memory contents. If no timer setting function in last remote control order, the system will memorize the last remote control order, the system will memorize the last remote control order and work with last remote control setting. In the last remote control order, there is ordinary timer function, if power off happen beffore the timer arrived, the system will memorize the last remote control timer function, and will recalculate. If there is timer function in last remote control order, but timer has arrive, system will run at timer on or timer off and power off, after repowered on, the system will run at the mode before power off. Timer function 1.Ordinary Timer setting: Timer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs. Timer off: Under unit off, the timer off function could be set up, if timer off has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs. Timer setting for hour: Timer on: if system is running, to set timer on, the system will continue to run, if unit is off to set up timer on, when timer on has arrived, the system will run at pressetting mode. Timer off: If system is off to set up the timer off, when to set up timer off, the unit will stand by, when unit is on, to set up timer off, when the timer off arrived, the system will stop to work. Timer setting change: When system is in Timer status, can set up timer on and timer off by wireless remote control, to reset up Timer also, the system will run at last setting status. When system is running, at the same time to set up Timer on and Timer off, the system will keep the present setting status, when time arrived, system will stop to work. When system stop, at the same time to set up Timer on and Timer off, the system will stop, untile the timer arrived, the system will start to work. Hereafter, when timer of timer on in every day arrived, it will run the presetting modes, after timer off arrived, the system will stop. (3) Auto button After powered on, press this button, it will run at Auto mode, when repressed, the unit will turns off. (4) Buzzer The controller is powered on and detect the signal received, the buzzer will beep. (5) Sleep function Under cooling or dehumidifying mode, the preset temperature will automatically rise by 1 , ine hour after setting of sleep program and rise by 1 after 2hours. Under heating mode, the preset temperature will automatically decrease by 1 program and decrease by another 1 after 2hours. one hour after setting of sleep (6) Turbo function The turbo function is available in Cool and Heat modes. (7) Dry function Dry function is available in Cool and Dehumidifying modes. (8) Auto fan speed control In this mode, indoor fan can run with Hig, Mid, Low speeds. (9) Up and down swing control After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet vent; After unit turned on, if to set up swing function, when indoor fan stop running, the guide louver will stop at current position, inner fan motor is running, guide louver will resume to swing.From Cool, Dry, Fan modes to Heat mode, the guide louver will be opened at D position, when turn on swing will run at (A-D); from Heat mode to Cool, Dry, Fan mode, the fan louver will turn to B position, if turn on the swing, it will run at (A-C). (10) Displayer Running figure and mode figure display After powered on, the figure will be displayed, then only Power/running indicator turn on. When using remote conroller to open the unit, it will turn on, at the same time to display current setting running modes. Dual 8 display When the unit is turned on, after powered on, the nixie tube will display the setting temp.(setting range is 1630 ). Under Auto mode, cooling and fan will display 25 , heating will display 20 , cooling only control display 25 . LCD Display When cooling and dehumidifying, the Cool and indicator will turn on, when heating, the Heat and Run indicaor will turn on, when in fan mode, the indicator will turn on. (11) PG motor lock protection When turn on the fan motor, if motor continuously run for a while and the running speed is very slow, in order to prevent motor automatically self-protection, it will stop running and display lock; If currently turns unit on, that dual 8 will display lock error code H6; If current is unit off, will not display the block error information. Manual 2 of functions of remote controller This manual is applicable to ASH-18AK, 24AK models, the centigrade is used for the following function manual, if there will be the Fahrenheit degree, that will be TF= TCX1.8+32. 1. Temperature parameter The room setting temperature(Tpreset) The room ambient temperature (Tamb) Basic Functions Once energized, the compressor should in no way be restarted unless after 3-minute time interval at least for the first energization, the compressor will be started without 3-minute lag. The compressor, once started, will not be stopped within 6 minutes with the charge of room temperature. Cooling Mode Cooling Conditions and Process When Tamb. Tpreset 1 , the unit will run under cooling mode, in which case the compressor and outdoor fan will start and the indoor fan will run at setting speed. When Tamb. Tpreset 1 , the compressor and the outdoor fan will stop, the indoor fan will run at setting speed. When Tpreset 1 Tamb. Tpreset 1 , the unit will maintain its original operating status. Under this mode, the four-way valve will not be powered on and the setting temperature range is 16-30 The displayer displays running signal, cooling signal and setting temperature. amb. . Start cooling Preset Original operating status Preset Stop cooling min. min. min. Compressor Outdoor fan Indoor fan Preset speed Run Stop Protection Antifreeze Protection If it is detected that the system is under antifreeze protection, the compressor and outdoor fan will be stopped, and the indoor fan will run at setting speed. When antifreeze protection is released and the compressor has stopped for 3 minutes, the unit will resume its original operating status. During antifreeze protection Compressor 3 min. Outdoor fan Indoor fan Preset speed Run Over current protection Stop If it is detected that the system amperage exceeds the specified value(about 22 A), the main unit will enter into the status that only the fan is running. After 3 minutes and overcurrent protection is released, the main unit will resume its original operating status .If it is 6 times continuously detected overcurrent protection (if the compressor has run over 6 mins continuously, the times of protection will be cleared),the main unit will be stopped on standby,the nixietube will display error code "E5", power indicator will blink and it is need to restart the unit by the wireless remote control. DRY Modes DRY Modes When Tamb. Tpreset 2 , the unit will run under DRY cooling mode, in which case the compressor and outdoor fan will be started and the indoor fan will run at low speed. When Tpreset 2 Tamb. Tpreset 2 , the unit will run under Dry mode, in which case the indoor fan will keep run at low speed, the compressor and outdoor fan will be stopped after 6mins. After 4 minutes, the compressor and outdoor fan will be restarted. The dehumidifying process is so repeated in cycle. When Tamb. Tpreset 2 , the compressor and outdoor fan will be stopped, the indoor fan will run at low speed. Under this mode, the switchover valve will not be powered on and the setting temperature range is 16-30 . Tamb. Start cooling Tpreset Dehumidifying Tpreset min. min. min. Stop running min. Compressor Outdoor fan Indoor fan Preset speed Stop Run Protection Antifreeze Protection Under dehumidifying and cooling mode, i f it is detected that the system is under antifreeze protection, the compressor and and outdoor fan will be stopped, and the indoor fan will run at low speed. When antifreeze protection is released and the the compressor has stopped for 3 minutes, the complete unit will resume its original operating status. Upon meeting "run 6 mins and stop 4 mins" dehumidify condition, i f it is detected that the system is under antifreeze protection,the compressor and outdoor fan will be stopped, and the indoor fan will run at low speed. When antifreeze protection is released and the compressor has stopped for 4 minutes, the complete unit will resume its original operating status. The other protections are the same with that under Cool mode. Other protection HEAT Mode (there is no this mode for cooling only unit) The conditions and process of heating When Tamb Tset 2 ,the system enters heating running, in this case, the reversal valve, compressor, outer fan enter simultaneously running.The indoor fan will delay at most for 2min to run. When Tamb Tset 4 ,the compressor and outdoor fan will stop, but the reversal valve is still with power on, the indoor unit will run at setting fan speed for 60s then will stop . When Tset 2 Tamb Tset 4 ,the unit will maintain its original operating status. Under this mode, the switchover valve will be powered on and the setting temperature range is 16-30 . Stop heating Tpreset Original running state Tpreset Tamb. 6Min. Start heating 3Min. 6Min. Compressor Outer fan Inner fan Setting fan speed 2Min. Setting fan speed 2Min. Inner fan Running Conditions and processes of defrost Stop This unit adopt intelligent defrosting,it can defrost according to the frosting conditions,dual 8 display H1 Protection Anti-high temperature protection If it is detected that the evaporator tube temperature is too high, the outdoor fan will be stopped. When the tube temperature resumes to normal,the outdoor fan will be restarted. Noise Silencing Protection If the unit is stopped by pressing ON/OFF, the reversal valve will be stopped after 2-minute l ag; or 2 minutes wi l l be delayed upon mode switching. Over current product The overcurrent protection is the same with the the over current protection under cool mode. Fan mode Under FA N mode, only the indoor fan runs at setting speed.The RUN indicator will be bright. Double 8 module indicator will display the setting temperature. When stand by, the power indicator is bright but the unit does not run. Auto Mode Under this mode, the system will automatically select its run mode (cool, dehumidify, heat or fan) with the change of ambient temperature. For protection function, same as under cooling and heating mode. Other controls Timer function Ordinary Timer setting: timer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs. Timer off: Under unit off, the timer off function could be set up, if timer off has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs. Timer setting for hour: Timer on: if system is running, to set timer on, the system will continue to run, if unit is off to set up timer on, When timer on has arrived, the system will run at pressetting mode. Timer off: If system is off to set up the timer off, when to set up timer off, the unit will stand by, when unit is on, to set up timer off, when the timer off arrived, the system will stop to work. Timer setting change: When system is in Timer status, can set up timer on and timer off by wireless remote control, to reset up Timer also, the system will run at last setting status. When system is running, at the same time to set up Timer on and Timer off, the system will keep the present setting status, when time arrived, system will stop to work. When system stop, at the same time to set up Timer on and Timer off, the system will stop, untile the timer arrived, the system will start to work. Hereafter, when timer of timer on in every day arrived, it will run the presetting modes, after timer off arrived, the system will stop. Auto button After powered on, press this button, it will run at Auto mode, when repressed, the unit will turns off. Buzzer The controller is powered on and detect the signal received, the buzzer will beep. Sleep function Under cooling or dehumidifying mode, the preset temperature will automatically rise by 1 , ine hour after setting of sleep program and rise by 1 after 2hours. Tpreset Preset temp. Tpreset Tpreset Tpreset 1hour 2hours 2hours above Under heating mode, the preset temperature will automatically decrease by 1 program and decrease by another 1 after 2hours. one hour after setting of sleep 1hr. 2hrs. 2hrs. above Tpreset Tpreset Tpreset temp. Tpreset Turbo function The turbo function is available in Cool and Heat modes. Dry function Dry function is available in Cool and Dehumidifying modes. Auto fan speed control In this mode, indoor fan can run with Hig, Mid, Low speeds. Up and down swing control After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet vent; After unit turned on, if to set up swing function, when indoor fan stop running, the guide louver will stop at current position, inner fan motor is running, guide louver will resume to swing.From Cool, Dry, Fan modes to Heat mode, the guide louver will be opened at D position, when turn on swing will run at (A-D); from Heat mode to Cool, Dry, Fan mode, the fan louver will turn to B position, if turn on the swing, it will run at (A-C). When unit is turned off, the guide louver will turn to position 0, the swing is only available after preset the swing function, and indoor unit is running. Note: When to set up at position L to B, A to C, B to D, the guide louver will swing between position W to D. Displayer Running figure and mode figure display After powered on, the figure will be displayed, then only Power/running indicator turn on. When using remote conroller to open the unit, it will turn on, at the same time to display current setting running modes. Dual 8 display When the unit is turned on, after powered on, the nixie tube will display the setting temp.(setting range is 16-30 ). When the preset temperature display signal has been received, the nixie tube will display the preset temperature; If the display ambient temperature signal has been received, the nixie tube will display the current indoor ambient temperature, if to set up others by remote controller that the display will maintain its status. At displaying ambient temperature, the unit received the remote control signal, it will display 5s preset temperature then turn to ambient temperature display. The ambient temperature sensor malfunction will display F1; Indoor tube sensor will display F2, wire jumper cap protection displays C5. PG motor lock protection When turn on the fan motor, if motor continuously run for a while and the running speed is very slow, in order to prevent motor automatically self-protection, it will stop running and display lock; If currently turns unit on, that dual 8 will display lock error code H6; If current is unit off, will not display the block error information. Power-off Memory Memory contents: Mode, UP/DOWN Swing, light, Set temp, Set fan speed. After de-energized, and re-energized, the unit will start to run with the memory function automatically. The system, if the last remote control signal do not set timer function, will memorize the last remote control signal and run according to it. If the last remote control signal has set timer function, the system is de-energized before the set time,when re-energized, the system will memorize the timer function, the set time will recalculate. If the last remote control signal has set timer function and the system is de-energized after the set time, when re-energized, the system will memorize the running status before de-energized. (18/24) Disassembly procedures for indoor unit Operating Procedures / Photos 1. Disassemble the front panel, Filter, Electric box cover Front Pane Screw Protect board Open the front panel ,Push the filter upwards to unloose the clasp, and then pull out the two filters. Screw off the screws fixing the electric box cover remove the cover out. Electric box cover Filter 2. Disassemble the guide louver Bend the guide louver so that the movable lock of guide louver is released to remove the guide louver. Guide louver 3. Disassemble the front case Open the 3 screw covers at the front case and screw off 5 screws. Pull out the movable latch at the front case with hand and then pull it backwards to disassemble the front case. Screw Operating Procedures / Photos 4. Disassemble the electric box cover Screw off the screws fixing the electric box cover and then open the cover, next unscrew the screws fixing the toggle switch on the cover, at last remove the cover out. Electric box cover 5. Disassemble water tray Loosen the clasp of the front and rear of water tray sub-assy and lift them up, pull out of the connection wire of swing motor, then can take out the water tray sub-assy. Note: Due to water tray is connected with the water drainage pipe, please pay more more attention do not hurt the fin on evaporator. Connector Water tray Claslp 5. Disassemble the electric box Screw off the grounding wire of the evaporator, remove the temperature sensor for the pipe, put Grounding wire Tube Sensor out the connection lines for the indoor motor. Screw off the screws fixing the electric box. Remove the electric box. Connector Screws Operating Procedures / Photos 6. Disassembling the evaporator Screw Screw off 5 screws fixing the left and right side of the evaporator, then elevate left side the evaporator to remove it backward. CAUTION: When repair, Carefully take out the evaporator and pay attention to protect the connecting pipe. Screw off one screw which fix the connection board clamp. Take down the connection board clamp. Screws 7. Disassembling motor and cross flow fan Screw off 4 screws fixing the motor cover and then take the motor cover out. Motor Press Plate Screw off the screw connecting the cross flow fan and motor, then pull out the motor and remove the cross flow fan. Screws Screw Cross flow fan Motor (18) Disassembly Procedures for Outdoor Unit Operating Procedures / Photos 1. Disassemble Handle and Top Cover Top Cover Unscrew the screw fixing the handle, then push it downwards to take it out. Unscrew the screws fixing the top cover, and then lift the top cover to remove it. Screws Handle Screw 2. Disassemble Rear Grill Unscrew the screws fixing the rear grill to re- Rear Grill move it. Screws 3. Disassemble Front grill Unscrew the screws fixing the front grill ,and then lift it upwards to remove it. Front Grill Screws Operating Procedures / Photos 4. Disassemble Front plate Unscrew the screws fixing the cabinet to remove it. Front side plate 5. Disassembel Right side plate Unscrew the 9 screws of the right side plate, then take down the right side plate. Right side plate 5. Disassemble Electric Box Sub-assy unscrew the screw of electric box, pull out the Screw lead out insert of compressor, four-way valve and motor, then take down the electric box. Electric box cover Operating Procedures / Photos 7. Disassemble Gas and Liquid Valves Unsolder the pipeline connecting with valves ( to prevent soldering gun from burning out the chassis).Unscrew 2 bolts fixing gas valve ,and then unsolder the weld spot between pipeline and gas valve to remove gas valve. Unscrew the 2 bolts fixing liquid valve, and then unsolder the weld spots between pipeline and liquid valve to remove liquid valve. (Note:During unsoldering ,wrap the valves with wet cloth to avoid damage for high temperature.) Liquid Valve Bolts Gas Valve 8. Disassemble Axial Flow Fan Unscrew the nut fixing the fan with a spanner to take out the fan. Axial Flow Fan Nut 9. Disassemble Outdoor Motor Unscrew the screws fixing the motor support, and then lift it upwards to remove it. Unscrew the screws fixing the motor and pull out the connection line between it and electric box to remove it. Motor Terminal Screw of Motor Motor Support Screws Operating Procedures / Photos 10. Disassemble Four-way Valve Only for cooling and heating unit Unscrew the fixing nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. Welding Weld spots Four-way Valve process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the lead-out wire of compressor. 11. Disassemble Capillary Unsolder the weld spots of capillary,valve and outlet pipe of condenser to remove the capillary. Prevent welding slag from blocking the capillary. Capillary 12. Disassemble Compressor Unsolder the pipeline connecting the compressor, and then unscrew the 3 foot-nuts fixing conpressor to remove it. Foot-nut (24) Disassembly Procedures for Outdoor Unit Operating Procedures / Photos 1. Disassemble Top Cover and Front Side Plate Unscrew the screws fixing the top cover, and then lift the top cover to remove it. Unscrew the 3 screws fixing the front side plate to remove it. Top Cover Screws Front Side Plate 2. Disassemble Rear Grill Unscrew the 4 screws fixing the rear grill to remove it. Rear Grill 3. Disassemble Cabinet Unscrew the screws fixing the cabinet to remove it. Cabinet Screw Operating Procedures / Photos 4. Disassemble Electric Box Sub-assy Unscrew the 2 screws fixing electric box to pull out the connection line between fan motor, compressor,four-way valve, and then lift the elec- Electric box tric box to take it out. Screws 5. Disassemble Right side plate Unscrew the screw of the right side plate, then take down the right side plate. Right side plate 6. Disassemble Gas and Liquid Valves Unsolder the pipeline connecting with valves ( to prevent soldering gun from burning out the chassis). Unscrew 2 bolts fixing gas valve ,and then unsolder the weld spot between pipeline and gas valve to remove gas valve. Unscrew the 2 bolts fixing liquid valve, and then unsolder the soldering spot between pipeline and liquid valve to remove liquid valve. (Note:During unsoldering ,wrap the valves with wet cloth avoid damage for high temperature.) Liquid Valve Bolts Gas Valve Operating Procedures / Photos 7. Disassemble Axial Flow Fan Unscrew the nut fixing the fan with a spanner to take out the fan. Axial Flow Fan Nut 8. Disassemble Outdoor Motor Unscrew the screws fixing the motor support, and then lift it upwards to remove it. Unscrew the screws fixing the motor and pull out the connection line between it and electric box to remove it. Motor Terminal Screw of Motor Motor Support Screws 9. Disassemble Four-way Valve Only for cooling and heating unit Unscrew the fixing nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. Welding process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the lead-out wire of compressor. Four-way valve Soldered point Operating Procedures / Photos 10. Disassemble Capillary Unsolder the weld spots of capillary,valve and outlet tube of condenser to remove the capillary. Prevent welding slag from blocking the capillary. Capillary 11. Disassemble Compressor Unsolder the pipeline connecting the compressor, and then unscrew the 3 foot-nuts fixing conpressor to remove it. Foot-nut PARTS GUIDE KING SERIES ASH-18AK, ASH-24AK (18/24) Exploded View of Components and Parts of Indoor unit Parts List for ASH-18AK Indoor unit No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Description Parts No. ASH-18AK Indoor unit Wall Mounting Frame 01252004 Rear Case 22202329 O-Gasket of Cross Fan Bearing 76512203 Screw Cap 24252015 Round Louver 10512429 Swing Lever 10582057 Swing Lever 10582058 Water Tray 20182057 Upper Air Deflector 10512085 Lower Guide Louver 10512086 Cross Flow Fan 10352022 Evaporator Assy 0100224502 Drain Pipe 05230014 Evaporator Support 24212067 Filter Sub-Assy 11122048 Front Case Assy 20002652 Front Panel Assy 20002843 Remote Controller 30510041 Displaying Light Board 30545033 Electric Box Cover 20112019 Fixed Clamp 71010103 Terminal Board 42010262 Electric Box Cover 20112020 Main PCB 30135096 Transformer 57X25C 43110237 Ambient Temperature Sensor 390000451 Tube Sensor 390000591 Sensor Insert 42020063 Electric Box 20112018 Lower Shieldof Electric Box 01592037 Upper Shieldof Electric Box 01592038 Stepping Motor 15213001 Motor Press Plate 26112095 Helicoid tongue 26252009 Fan Motor 15012077 Pipe Clamp 26112096 Connecting Cable 400205402 The data are subject to change without notice. Qty Price rank 1 1 1 3 11 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 AK AW AC AA AB AC AC AW AF AF AN BD AD AF AD AU AM AT AZ AE AB AD AE BA AM AD AD AD AK AE AD AK AE AH AX AD AN Parts List for ASH-24AK Indoor unit No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Description Parts No. ASH-24AK Indoor unit Wall Mounting Frame 01252004 Rear Case 22202329 O-Gasket of Cross Fan Bearing 76512203 Screw Cap 24252015 Round Louver 10512429 Swing Lever 10582057 Swing Lever 10582058 Water Tray 20182057 Upper Air Deflector 10512085 Lower Guide Louver 10512086 Cross Flow Fan 10352022 Evaporator Assy 010022365 Drain Pipe 05230014 Evaporator Support 24212067 Filter Sub-Assy 11122048 Front Case Assy 20002652 Front Panel Assy 20002843 Remote Controller 30510041 Displaying Light Board 30545033 Electric Box Cover 20112019 Fixed Clamp 71010103 Terminal Board 4201026201 Electric Box Cover 20112020 Main Board 30135163 Transformer 57X25C 43110237 Ambient Temperature Sensor 390000451 Tube Sensor 390000591 Sensor Insert 42020063 Electric Box 20112018 Lower Shieldof Electric Box 01592037 Upper Shieldof Electric Box 01592038 Stepping Motor 15213001 Motor Press Plate 26112095 Helicoid tongue 26252009 Fan Motor 15012077 Pipe Clamp 26112096 Connecting Cable 400205382 The data are subject to change without notice. Qty Price rank 1 1 1 3 11 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 AK AW AC AA AB AC AC AW AF AF AN BF AD AF AD AU AM AT AZ AE AB AD AE BB AM AD AD AD AK AE AD AK AE AH AX AD AN (18) Exploded View of Components and Parts of outdoor unit Parts List for ASH-18AK Outdoor unit No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23.1 23.2 23.3 24 25 26 27 28 Description Parts No. ASH-18AK Outdoor unit Small Handle 26235401 Axial Flow Fan 10333426 Fan Motor 15013070 Motor Support 01703059 Condenser Assy 01113033 Condenser Clamp 01175202 Top Cover 01255001 Rear Grill 014730371 Electrical Box 01403835 Capacitor CBB61 3.5kuF/450V 33010010 Capacitor Clamp 02141375 Capacitor 33000039 Terminal Board 2-8 42011103 Terminal Board 42010265 4-way Valve 430004032 4-way Valve Accessary 430004002 Capillary Assy 03103555 Right Side Plate 01305013 Handle 26235254 Gas Valve Assy 07130213 Cut-off Valve 07100003 Valve support 01713076 Compressor and Fittings 00103007 Build in Compressor Gasket 4CYC00008 76710202 Clapboard Sub-Assy 01233035 Drainage Connecter 06123401 Chassis 0120362602P Front Side Plate 01305015 Front Grill 22415001 The data are subject to change without notice. Qty Price rank 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 AC AR AZ AF BK AB AH AG AF AG AB AM AD AE BA AM AZ AH AC AH AG AD BW 3 1 1 1 1 1 AE AK AA AU AW AL (24) Exploded View of Components and Parts of outdoor unit Parts List for ASH-24AK Outdoor unit No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24.1 24.2 24.3 25 26 27 28 Description Parts No. ASH-24AK Outdoor unit Panel Grille 22414102 Front Plate 01433017 Axial Flow Fan φ472X165 10338731 Fan Motor 15015421 Motor Support 01703027 Condenser Assy 01113034 Top Cover 01255262 Mesh Enclosure 01473028 Electric Box Cover Plate 01413047 Electric Box Sub-Assy 01403248 Capacitor CBB65 50uF/450V φ50X120 33000001 Capacitor CBB61 3.5kuF/450V 33010010 Terminal Board 42010194 4-way Valve 03023724 Terminal Board 2-8 42011103 4-way Valve Accessary 430004002 4-way Valve 430004032 Handle 26235253 Gas Valve Sub-Assy 07103030 Liquid Valve Assy 07133024 Rear Side Plate Sub-Assy 01303115 Valve Support Sub-Assy 01715001 Capillary Assy 03103556 Compressor and Fittings 00100525 Build in Compressor Gasket 4CYC00008 76710202 Isolation Washer 70410523 Mid Clapboard Sub-Assy 01233024 Underpan Sub-Assy 01205073 Front Side Plate 01303023 The data are subject to change without notice. Qty Price rank 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 AL AW AR BA AE BL AQ AG AF AF AL AG AD AY AD AM BA AC AV AU AM AD AZ CA 3 1 1 1 1 AE AC AK AU AG 9 Failure and analysis Note: When replacing the controller, make sure insert the wire jumper into the new controller, otherwise, the running indicator off 3s, blink 15 times, (the dual eight will display C5) but cannot turn on the unit. The breaker trips at once when it Measure insulation resistance to ground to see if there is any leakage. is set to "ON". Trip of breaker or blow of fuse The circuit or the part of the air conditioner has malfunction. They heat and break the insulation The breaker trips in few minutes when it is set to "ON" and lead to short circuit or creepage. Measure the insulation resistance or eliminate the malfunction one by one. If the breaker itself has Air conditioner can not start up malfunction, then replace the breaker. The air conditioner No power Check power supply circuit. Power plug is not well plugged in and poor connection Check if the plug is properly plugged in and make the loose contact firm. does not react after it is powered ( after Fuse of controller burnt out Change controller fuse the plug is inserted, the buzzer does The transformer connection is loose or has bad not sound and the contact or the transformer has malfunction remote startup has Fasten the wiring; measure the output voltage of the transformer, if it is incorrect, change the transformer no response) The remote controller Controller is broken Check remote controller Remote controller is short of power Change batteries Remote controller malfunction First, press the manual switch button AUTO, does not receive signals (after it is powered, the buzzer above methods. If it runs normally after will sound, unless it has if there is no response,check based on the Receiver loose or poor connection malfunction) pressing the button,check again whether the installation position and the connection wire of the reception head is correct. If it is Receiver is broken Power voltage is too low correct,then replace the receiver or the remote controller. heck the voltage. If it is lower than 10£¥ of the rated voltage, check the cause, improve the power supply condition and add the stabilized voltage power supply. Controller malfunction (IC2003 broken, creepage of parallel capacitor of relay loop, relay is broken etc.) In cool, heat mode,the outdoor unit and compressor will not run. Change controller Wire loose or wrong connection Correctly wire according to the drawing Improper setting of temperature Adjust setting temp. Improper set of temperature Adjust set temperature If cooling (heating) load is proper Check the forecasted load of cooling (heating) The refrigerant has leakage or is insufficient Malfunction of refrigerant flow Leakage between the high pressure and the low pressure inside the compressor Malfunction of four-way valve Poor COOL(HEAT) operation Local block of capillary Blockage of cooling system Heat insulation for the connection pipes of the indoor unit and the outdoor unit is bad. heck and fill the leakage, then vacuumize it and supplement the refrigerant as required Replace the compressor Replace the four-way valve Replace the capillary Judge whether the system is blocked by observing the condensation of evaporator and the pressure value of the high pressure manometer and take measures to deal with the system. Make sure that heat insulation for the thick and thin pipes is good. Heat insulation must also be provided for the joint andthe exposed part of the copper pipe . Block of outdoor heat exchanger Clean the dust accumulated on the surface of the heat exchanger. Air filter were blocked Clean the filter Fan speed was set too slow Air circulation is insufficient Fan rotation speed becomes low The installation position of the outdoor unit is not appropriate. The outdoor temperature is too high. The air tightness is not enough. People come in and out too frequently. There are heating devices indoors. To set the fan speed to high or middle speed Capacitor damage Replace the capacitor Motor damage Replace the motor Good ventilation must be provided for the installation position of the outdoor unit. Properly install the rainproof plate or the sunproof plate. If the maximum cool air still can not meet the requirement, it is suggested to replace the air conditioner. Keep certain air tightness indoors, try not to use electricalappliance with large quantity of heat The indoor fan motor is burned or breaks or has the heat protector malfunction. The fan does not run when it is set to supply air. In the cooling and heating mode, the compressor runs, but the outdoor fan does not run. The compressor is too hot and leads to the action of the protector. The built-in heat protector of the motor breaks frequently because the motor is abnormal. Replace the fan motor Wrong connection Make the correction connection based on the circuit drawing. The fan capacitor has open circuit or is damaged. Replace the fan capacitor of the same type and same specification. The outdoor fan motor is damaged. Replace the fan motor Wrong connection Make the correct connection based on the circuit drawing The outdoor fan capacitor is damaged. Replace the fan capacitor Malfunction of compressor Replace the compressor Breakage of running capacitor of compressor Replace the capacitor The voltage is too low or too high. Manostat is recommended. Wrong wire connection Connect the circuit diagram correctly The protector itself has malfunction. The refrigerant is not enough or is too much. The compressor is too hot and leads to the action of the protector. Replace the fan motor or the defective part. The capillary is blocked and the temperature rises. The compressor does not run smoothly or is stuck. The air discharge valve is damaged The protector itself has malfunction. Use the multimeter to check whether the contact of the compressor is on when it is not overheated. If it is not on, then replace the protector Adjust the volume of the refrigerant Replace the capillary Replace the compressor Replace the protector The torque of the swing motor is not enough The swing fan does not run. Wrong connection The controller is damaged(IC2003 is damaged, the swing relay can not close, etc) First, check whether the connection is wrong. If no, replace the parts Drainage pipe blocked or broken Change drainage pipe Water leakage Wrap of refrigerant pipe joint is not close enough. Re-wrap and make it tight. Fan of indoor unit contacts other parts. Adjust fan location. Foreign object in indoor unit Take out the foreign object. Compressor shakes too much. Abnormal sound and shake Adjust support washer of compressor, and tighten loosen screws. Touch of pipeline of outdoor unit Separate the touching pipeline. Touch of inner plates 1. Tighten connect screw. 2. Stick absorbing clay between plates. Louver of outdoor unit touched outer case. Adjust location of louver. Abnormal sound inside compressor Change compressor Abnormal solenoid sound from 4-way valve when heating Circuit-short inside solenoid of the valve and change the solenoid valve. There are no heating malfunctions in the above for the cooling only unit. PG motor locked protection H6: Probable reasons: 1. Air vents were blocked which may cause the fan speed is too slow; 2. Fan blade locked; 3. Motor locked; 4. Fan motor capacitor damaged; 5. Motor damaged (ordors, winding, open circuit or shortcircuit are not normal, when testing the winding, pls distinguish whether the motor body cause temperature is too high so that bring on the thermal protector starts up) 6. IC board damaged (during normally running, there are voltage at both capacity input and output) 7. Mainboard damaged. 8. Motor thermal protection. Disposal methods: 1. Remove the obstruction; 2. Reassembling; 3. Replace motor; 4. Replace capacitor; 5. Replace motor; 6. Replace circuit board; 7. Replace mainboard; 8.Under the normal circumstances, the motor will not act, but in other circumstances, such as evaporator is very dirty, to much dust attached on the fan blade that will cause the motor overload running, so that during the operation, frequent thermal protection will happen, so it is need to be cleaned or replaced.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement