Datalogic | Touch 90 pro | User manual | Reference Guide


Add to my manuals
2 Pages

advertisement

Datalogic | Touch 90 pro | User manual | Reference Guide | Manualzz

Datalogic Scanning, Inc.

959 Terry Street

Eugene, Oregon 97402

Telephone: (541) 683-5700

Fax: (541) 345-7140

An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written per-mission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or

“Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes.

Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.

Should future revisions of this manual be published, you can acquire printed versions by contacting your

Datalogic representative. Electronic versions may either be downloadable from the Datalogic website

(www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the

"Contact Datalogic" page.

DISCLAIMER

Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic is a registered trademark of Datalogic S.p.A. in many countries and the Datalogic logo is a trademark of Datalogic S.p.A. all licensed to Datalogic Scanning, Inc. All other trademarks and trade names referred to herein are property of their respective owners.

SERVICES AND SUPPORT

Datalogic provides several services as well as technical support through its website. Log on to www.scanning.datalogic.com

and click on the links indicated for further information including:

PRODUCTS

Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including:

- Datalogic a multi-platform utility program, which allows device configuration using a PC. It provides RS232/USB-COM interface configuration as well as configuration barcode printing.

SERVICES & SUPPORT

- Datalogic Services - Warranty Extensions and Maintenance Agreements

- Authorised Repair Centres

CONTACT US

E-mail form and listing of Datalogic Subsidiaries

WARRANTY

Datalogic warranties this product against defects in workmanship and materials, for a period of 5 years from the date of shipment, provided that the product is operated under normal and proper conditions.

Datalogic has the faculty to repair or replace the product; these provisions do not prolong the original warranty term.

The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.

Datalogic Scanning, Inc.

959 Terry Street

Eugene, OR 97402

07 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el

Touch 65

Touch 90 e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: den nachstehenden angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:

89/336/EEC EMC Directive e 92/31/EEC, 93/68/EEC emendamenti successivi and et further amendments ses successifs amendements und y späteren Abänderungen succesivas enmiendas

Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti.

On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety.

Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits.

Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und

Produktsicherheit entsprechen.

Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto.

Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:

This declaration is based upon compliance of the products to the following standards:

Cette déclaration repose sur la conformité des produits aux normes suivantes:

Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:

Esta declaración se basa en el cumplimiento de los productos con la siguientes normas:

EN 55022 (C

LASS

B ITE), A

UGUST

1994 :

A MENDMENT A1 (C LASS B ITE), O CTOBER 2000 :

EN 55024, S EPTEMBER 1998 :

L

IMITS AND METHODS OF MEASUREMENTS OF RADIO

DISTURBANCE OF INFORMATION TECHNOLOGY EQUIPMENT

I

NFORMATION

T

ECHNOLOGY

E

QUIPMENT

.

I

MMUNITY

CHARACTERISTICS .

L IMITS AND METHODS OF MEASUREMENTS

March 1st, 2007

Touch ™ 65/90 Pro

CONTACT READERS

QUICK REFERENCE GUIDE

820001263eng (Rev. F) 9/07

UPDATES AND LANGUAGE AVAILABILITY

UK/US

The latest drivers and documentation updates for this product are available on

Internet.

Log on to: www.scanning.datalogic.com

I

Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana.

Collegarsi a: www.scanning.datalogic.com

F

Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française.

Cliquez sur : www.scanning.datalogic.com

D

Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation für dieses Produkt. Die deutschsprachige Version dieses Handbuches ist auch verfügbar.

Adresse : www.scanning.datalogic.com

E

En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. También está disponible la versión en español de este manual.

Dirección Internet : www.scanning.datalogic.com

CONNECTIONS

USB

DISCONNECTING THE CABLE

WEDGE

RS232

PEN

COMPLIANCE

LED CLASS

Class 1 LED product.

This product conforms to EN60825-1:2001.

FCC COMPLIANCE

Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.

This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and

(2) this device must accept any interference received, including interference which may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

POWER SUPPLY

This device is intended to be connected to a UL Listed/CSA Certified computer which supplies power directly to the reader or else be supplied by a UL Listed/CSA

Certified Power Unit marked “Class 2” or LPS power source rated 5 V, minimum

150 mA, which supplies power directly to the reader via the power connector of the cable.

WEEE COMPLIANCE

PATENTS

This product is licensed under the following U.S. patent:

6,158,661

This product is covered by one or more of the following patents:

U.S. patents 5,917,176; 5,992,740; 6,010,073; 6,305,606 B1; 6,517,003 B2; and

6,712,271 B2

European patents 829,814 B1; 851,378 B1; and 895,175 B1

Additional patents pending.

DEFAULT VALUES

USB-KBD DEFAULT SETTINGS

USA keyboard, FIFO enabled, inter-character and inter-code delays disabled, control character emulation = ctrl+shift+key.

DATA FORMAT : code identifier disabled, no field adjustment, code length not transmitted, no header, terminator = ENTER, character replacement disabled.

RS232 Standard DEFAULT SETTINGS

9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO enabled, serial trigger lock disabled.

DATA FORMAT : code identifier disabled, no field adjustment, code length not transmitted, no header , terminator = CR-LF , character replacement disabled.

WEDGE DEFAULT SETTINGS

USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock unchanged, inter-character and inter-code delays disabled, control character emulation = ctrl+shift+key.

DATA FORMAT : code identifier disabled, no field adjustment, code length not transmitted, no header , terminator = ENTER , character replacement disable.

PEN DEFAULT SETTINGS interpret mode, conversion to code 39 disabled, output level normal, idle level normal, minimum output pulse 600 μ s, overflow medium, inter-block delay disabled.

CODE SELECTION

Enabled codes

EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions

Interleaved 2/5 check digit control and transmission, variable length code; 4-99 characters

Standard Code 39 no check digit control, variable length code; 1-99 characters

Code 128 variable length code; 1-99 characters

Disabled codes

EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,

Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes

TECHNICAL FEATURES

Electrical Features

Power Supply

Consumption:

Maximum

Operating

Sleep mode &

USB Suspend Mode

Max. Scan Rate

Reading Indicators

Optical Features

Sensor

Reading Field

Max. Resolution

PCS

Environmental Features

Working Temperature

Storage Temperature

Drop Resistance

ESD Protection

Protection Class

Mechanical Features

Weight (without cable)

Cable Length

5 Vdc ± 5%

150 mA @ 5 Vdc

100 mA @ 5 Vdc

< 500 μ A @ 5 Vdc

256 scans/sec

LED, Beeper

Touch™ 65 Pro Touch™ 90 Pro

CCD solid state (2048 pixels)

63 mm typical 80 mm typical

0.10 mm

(4 mils)

0.13 mm

(5 mils) min. 15% (Datalogic Test Chart)

0 ° to +55 ° C / 32° to 131 °F

-20 ° to +70 ° C / -4° to 158 °F

1.2 m (3 ft 11 in)

16 KV

IP30 about 160 g (5.6 oz) about 195 g (6.8 oz)

2 m (6 ft 6 in)

RESTORE DEFAULT

RESTORE DEFAULT

Ì$+$*oÎ

To change the defaults refer to the HHD II Software Configuration Manual, part number 90ACC1877 , or to the DL Sm@rtSet™ Configuration program, both downloadable from the website.

INTERFACE SELECTION

Select one of the interface codes according to your application.

USB INTERFACE SELECTION

USB-KBD

Ì$+UA03$-:Î

USB-KBD - ALT-mode

Ì$+UA04$-@Î

USB-COM *

Ì$+UA02$-4Î

Ì$+UA01$-.Î

* When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software, which can be downloaded from the web site http://www.scanning.datalogic.com.

PEN EMULATION INTERFACE SELECTION

PEN

Ì$+CP6$-BÎ

RS232 INTERFACE SELECTION

RS232 Standard

Ì$+CP0$-$Î

Nixdorf Mode A

Ì$+CM2EC0$->Î

Fujitsu

Ì$+CM1$-ÈÎ

Ì$+CM0$-ÃÎ

WEDGE INTERFACE SELECTION

Wedge IBM AT or PS/2 PCs

Ì$+CP500$-aÎ

PC Notebook - ALT mode

Ì$+CP508$-2Î

Ì$+CP505$-ÈÎ

IBM AT - ALT mode

Ì$+CP507$-+Î

Many other interfaces are supported and can be selected from the

HHD II Software Configuration Manual available online at http://www.scanning.datalogic.com. Other supported interfaces:

USB : USB-IBM-Table Top; USB-KBD-APPLE

WEDGE : IBM XT; IBM SURE1; IBM Terminal 3153; IBM Terminals 31xx, 32xx,

34xx, 37xx; Wyse Terminals ANSI – PC –ASCII – VT220 style Keyboards; Digital

Terminal VT2xx/VT3xx/VT4xx; APPLE ADB Bus

KEYBOARD NATIONALITY

USB-KBD and Wedge users should select one of the following wedge keyboard nationality codes according to your keyboard.

Belge

Ì$+FJ7$-8Î

Deutsch

Ì$+FJ3$-$Î

English

Ì$+FJ4$-)Î

Español

Ì$+FJ6$-3Î

Français

Ì$+FJ2$-ÊÎ

Italiano

Ì$+FJ1$-ÅÎ

Japanese

Ì$+FJ8$-=Î

Svenskt

Ì$+FJ5$-.Î

USA (Default)

Ì$+FJ0$-|Î

DATA FORMAT TERMINATORS

For your convenience, some common Terminators are given below. For other

Header/Terminator selections, Data Format and Advanced Data Format parameters see the HHD II Software Configuration Manual.

CR-LF

Ì$+EA120D0A$-ÃÎ

Enter

Ì$+EA1183$-0Î

Tab

Ì$+EA1184$-8Î

None

Ì$+EA10$-dÎ

OPERATING TEST

Read the TEST code below.

Code 128

USING TOUCH™ PRO SERIES READERS

scanning line trigger button

Touch™ Pro readers scan barcodes on contact . All models have a hardware trigger button, which by default must be pressed to read a code. After configuring the reader interface type, the software trigger parameter (available in this manual) can be selected so that the reader operates like a model without trigger.

Code scanning is performed along an imaginary line passing across the reading window. This imaginary line must pass through the entire code.

Successful scanning is obtained by keeping the handle of the reader parallel with respect to the code surface, see the figure above.

TRIGGER SELECTION

After configuring the reader interface type, the software trigger parameter can be selected so that the reader operates like a model without trigger.

Software Trigger

Ì$+BK0$-tÎ

♦ Hardware Trigger

Ì$+BK1$-yÎ t e s t