Mitsubishi | QJ71WS96 | User manual | Web Server Module
Add to my manuals2 Pages
Mitsubishi QJ71WS96 Web Server Module enables you to monitor and control your Mitsubishi PLC remotely via the internet, without the need for a dedicated web server PC. It offers various connection options, including ADSL, analog modem, and LAN, allowing you to adapt to your network environment. You can monitor tag data, PLC status, and event history, and receive email notifications for specific events. With its user-friendly interface, you can easily set up event monitors and view saved data on your web browser.
advertisement
▼
Scroll to page 2
Outline dimension drawings December 2002 (3) Monitoring events The Web Server Module monitors the PLC CPU state according to the device value or time conditions, and saves the event history. It shows the saved event history data on the Web browser. If necessary, it can send by e-mail when the event occurs. New Product Release Mitsubishi PLC 98 No. 186E (2) The Web Sever Module monitors the CPU and data according to the event monitor settings. Web Server Module (1) The Web Server Module displays the event history with the event history monitor. Tag data monitor Client QJ71WS96 type Time data interval monitor Tag data Web Server Module 27.4 Internet Event monitor settings Event history monitor Tag name Element name Condition Trigger value A process Pressure >= 120 A process Temperature = 30 A process > 200 Water level 90 CPU status monitor ... Event type : Product list Tag monitor Status Tag name Element name Condition Occurrence A process Pressure > Part name 02/07/01 12:55:10 Occurrence A process Temperature >= QJ71WS96 type Web Server Module 02/07/01 14:10:00 Occurrence A process Water level = The Web Server Module is now available to realize remote monitoring to the Q Series! ... Type QJ71WS96 ... ... ... ... ... (1) User sets the event monitor with the Web browser. Date 02/07/01 09:00:00 Manuals (4) If necessary, the Web Server Module can send an e-mail when event occurs. Web Server Module Manual name Client E-mail Web Server Module User’s Manual (Hardware) Web Server Module User’s Manual Manual shipping style IB/SH No. Type code Enclosed with product IB-0800231 13JT97 Optional SH-080320E 13JR58 Access the PLC via the internet No Web server PC Easy setting with Web browser Various connections (ADSL, modem, LAN, etc.) Data logging function Event occurrence Internet service provider (Separate contract for services required) Logging data Tag data Internet Microsoft Windows and Microsoft Windows NT are registered trademarks of Microsoft Corporation in the United States and other countries. Netscape is a registered trademark of Netscape Communications Corporation in the United States and other countries. Ethernet is a registered trademark of Xerox Corporation. Other company names and product names used in this document are trademarks or registered trademarks of the respective companies. Internet service provider (Separate contract for services required) (4) Various connections There are various connection methods to match the user’s network environment. Web Server Module Client Country/Region Sales office Tel/Fax MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Tel : +55-11-283-2423 AV. Paulista 1471, Conj. 308, Sao Paulo City, Sao Paulo State, Fax : +55-11-288-3047 Brazil Taiwan Setsuyo Enterprise Co., Ltd. 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Tel : +886-2-2299-2499 Fax : +886-2-2299-2509 Germany Mitsubishi Electric Europe B.V. German Branch Gothaer Strsse 8 D-40880 Ratingen, GERMANY Tel : +49-2102-486-0 Fax : +49-2102-486-7170 Korea Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Herts., AL10 8XB,UK Tel : +44-1707-276100 Fax : +44-1707-278695 HAN NEUNG TECHNO CO.,LTD. 1F Dong Seo Game Channel Bldg., 660-11,Deungchon-dong Kangsec-ku, Seoul, Korea Tel : +82-2-3660-9552 Fax : +82-2-3664-8372 U.K Singapore Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Dir. Colleoni, Pal. Perseo - Ingr.2 Via Paracelso 12, 20041 Agrate B., Milano, Italy Tel : +39-039-6053344 Fax : +39-039-6053312 Mitsubishi Electric Asia Pte, Ltd. 307 ALEXANDRA ROAD #05-01/02, MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943 Tel : +65-6473-2308 Fax : +65-6476-7439 Thailand Spain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80 08190 - Sant Cugat del Valles, Barcelona, Spain Tel : +34-93-565-3131 Fax : +34-93-589-2948 F. A. Tech Co.,Ltd. 898/28,29,30 S.V.CITY BUILDING,OFFICE TOWER 2,FLOOR 17-18 RAMA 3 ROAD,BANGKPONGPANG,YANNAWA,BANGKOK 10120 Tel : +66-2-682-6522 Fax : +66-2-682-6020 France Mitsubishi Electric Europe B.V. French Branch 25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France Tel : +33-1-5568-5568 Fax : +33-1-5568-5685 Indonesia Tel : +62-21-663-0833 Fax : +62-21-663-0832 South Africa Circuit Breaker Industries LTD. Tripswitch Drive, Elandsfontein Gauteng, South Africa Tel : +27-11-928-2000 Fax : +27-11-392-2354 P.T. Autoteknindo SUMBER MAKMUR JL. MUARA KARANG SELATAN BLOK A UTARA NO.1 KAV. NO.11 KAWASAN INDUSTRI/ PERGUDANGAN JAKARTA UTARA 14440 Hong Kong Ryoden Automation Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Tel : +852-2887-8870 Fax : +852-2887-7984 India Messung Systems Put,Ltd. Tel : +91-20-712-2807 Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,PUNE- Fax : +91-20-712-0391 411026 Ryoden Automation Shanghai Ltd. 3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China Tel : +86-21-6475-3228 Fax : +86-21-6484-6996 Country/Region Sales office Brazil ADSL Analog modem LAN * Obtain internet service for internet connection. * Obtain comunication devices and cables. China Tel/Fax Australia Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia Tel : +61-2-9684-7777 Fax : +61-2-9684-7245 Device data Web Server Module MELSECNET/H, etc. HEAD OFFICE: 1-8-12, OFFICE TOWER Z 14F HARUMI GHUO-KU 104-6212, JAPAN NAGOYA WORKES: 1-14, YADAMINAMI5, HIGASIKU, NAGOYA, JAPAN 2 0212 (MDOC) Specifications subject to change without notice. Printed in Japan on recycled paper. Modem * Prepared by user Control and monitor the PLC equipment using the Web browser. Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO14001 (standards for environmental management systems) and ISO9001(standards for quality assurance managememt systems) List of functions Features (1) Gathering tag data Function The Web Server Module gathers tag data that is a group of device data of PLC CPU sitting on the network, and it shows collected tag data on the Web browser by specifying the tag name. Monitor functions Web Server Module (3) The Web Server Module shows specified tag data. (2) The Web Server Module collect device data in tag units according to the tag settings. Client Internet CPU1: Monitors the device value. Tag data monitor Monitors the tag data. Number of simultaneous connectable nodes 5 Logging monitor Monitors the logging data. HTTP version 1.0 Event monitor Monitors the event history. PLC diagnosis monitor Monitors the operation state of the PLC CPU. User area capacity Standard ROM: Maximum 5MB When Compact FlashTM card is used: Maximum 512MB (Including the home page capacity and logging capacity) User authentication Account Number: Maximum 16 (User ID: 1 to 20 characters, Password: 8 to 14 characters) Value (Component name) D100 100 Pressure D200 20.3 Temperature D300 9 Water level D400 70 Humidity Tag setting Tag data monitor Tag name : Tag name : O1: A process O1: A process Component name CPU name Device Component name Value Pressure CPU1 D100 Pressure 100 Temperature CPU1 D200 Temperature 20.3 Water level CPU1 D300 Water level 9 Humidity CPU1 D400 Humidity 70 Production quantity CPU2 D10 Production quantity 1280 Item Registers and collects a group of device data from each PLC CPU on the network as a tag, and displays it on the browser. Logging function Collects the tag data collected in chronological order and displays it on the browser. Event monitor function Monitors the tag data, time interval and CPU status, and displays the history of events on the browser. Access log Provided Sends e-mail. Sends e-mail from PLC CPU Sends e-mail with event monitor function Parts for creating user screen E-mail function Java applet: 6 types (File supplied as standard with the Web Server Module can be used (Creating by users is not possible)) Operation check browser Internet Explorer 5.5/6.0 Microsoft Corporation (refer to Remarks (3)) Java VM version: Build number 3309 or later (refer to Remarks (2)) FTP function Transfers files between the Web Server Module and clients. FTP server function FTP client function Subject Maximum 373 words Main text Maximum 960 words Attached file Maximum 256 words (512k bytes) Attached file format MIME Format MIME version 1.0 Attached file Data CSV format File name: XXXX.csv (1 to 8 characters) Division Attached files cannot be divided Encryption None Compression None Communication with mail server SMTP (send server) port number = 25 Operation check mailer Internet Explorer 5.5/6.0 Microsoft Corporation (Outlook Express 5.5/6.0) Server function Provided Number of simultaneous connectable nodes 10 Client function Provided (PUT only) Tag Tag number: Maximum 64, Component number: Maximum 64 Logging Loging number: Maximum 64, Lines number (Number of records): Maximum 10000 lines Monitor interval 1 to 32767 seconds Browser Access log function Displays the access log to the Web Server Module on the browser. Address notification function Notifies the Web Server Module’s address to clients. Data management function Backs up and restores the standard ROM, and formats the compact flash card. Diagnosis function Checks itself and connection. User screen creation function Creates the user’s original monitor screen using parts (Java applets) supplied by Mitsubishi. Value (Component name) D10 1280 Production quantity (1) User sets the tag and tag components with the Web browser. FTP client Item Specifications Interface (*1) Data transmission speed 10BASE-T/ 100BASE-TX section 10BASE-T 100BASE-TX 10Mbps 100Mbps Maximum number of nodes/connection Cascade connection: Maximum 4 stages (2) The Web Server Module is gathering tag data according to the logging settings. RS-232 compliant (D-Sub 9 pin) Interface The tag data are saved successively. The saved logging data are shown on the Web browser by specifying the logging name. Communication method Full-duplex transmission Synchronization method Start-stop synchronization Transmission speed (bps) 9600,19200,38400,57600,115200 Maximum 15m Transmission distance (3) The Web server module shows the logging data. Client RS-232 section Data format Start bit 1 Data bit 8 Logging data Logging setting Tag name Flow control (RS/CS control) is available Recommended cable 7/0.127 P HRV-SV, Outer diameter: 8.5mm or more (Oki Electric Cable Co., Ltd.; Number of pairs indicated in section) A process Interval specification (300 [seconds]) B process Interval specification (60 [seconds]) C process Time specification (05:00:00) (1) User sets the logging conditions with the Web browser. Logging name : Display form : A process List display (*) Compact flash card section 3.3V Supplied power voltage One card Number of mountable cards Date Pressure Temperature 02/07/01 09:00:00 90 20.3 9 Number of occupied input/output points 02/07/01 09:05:00 97 20.5 7 Number of writing times to standard ROM (flash ROM) 02/07/01 09:10:00 101 20.4 8 5VDC internal current consumption 02/07/01 09:15:00 100 20.4 10 External dimensions 02/07/01 09:20:00 103 20.2 13 Weight Noise withstand level, withstand voltage, insulation resistance (1) Compact flash card The type 1 storage card that complies with Compact FlashTM specifications can be used with this Web Server Module. Only one compact flash card can be mounted on the Web Server Module. The specifications of the analog modem and ADSL modem that can be used with the Web Server Module are shown below. Function Analog modem 5% TYPE 1 card Card size Water level * The logging data is displayed as a list or graph. 1 9-pin D-sub (male) screw fixed type External wiring appricable connector Logging monitor Logging interval None Transmission control Internet Connection configuration devices (2) Analog modem, ADSL modem 1 Stop bit Parity check Tag data Cascade connection: Maximum 2 stages 100m Automatic negotiation function compatible (Automatic recognition of 10BASE-T/100BASE-TX) Support function (2) Logging the tag data Data collection Base band Transmission method Maximum segment length (*2) Web Server Module E-mail FTP server (1) Communication and I/F specifications Device Web server Performance specifications CPU2: Specifications Tag function Tag data Device (2) Software specifications Details Device monitor According to power supply module at station where Web Server Module is mounted 32-points per slot (I/O assignment: 32 intelligent points) Maximum 100,000 times to same area Details Web Server Module interface Compatible with Web Server Module’s CH2 (RS-232) transmission speed (*1) Data communication control command Compatible with Hayes AT commands DR signal control Capable of turning only DR (DSR) signal ON independently Web server unit interface Interface compatible with Web Server Module’s CH1 (10BASE-T/100BASE-TX) transmission speed Protocol (*2) PPPoE (PPP over Ethernet) PPPoA (PPP over ATM) *1. Refer to section (1) in the performance specifications for details on the Web Server Module CH1/CH2 transmission speed. *2. Obtain an internet service provider and static IP address to use the PPPoE router type ADSL modem or PPPoA type ADSL modem. Notify the client of the global IP address (static IP address) assigned to the ADSL modem when connecting the Web Server Module to the network with the ADSL modem. 0.65A 98 (3.86 in.) (H) x 27.4 (1.08 in.) (W) x 90 (3.54 in.) (D) [mm] 0.17 kg (0.37 lb.) *1. The Web Server Module automatically switches between the 10BASE-T/100BASE-TX according to connection. *2. Length between hub and node. 3 Precautions for internet connection infrastructure environment Note that depending on the internet connection infrastructure environment in each country and region, you may not be able to correctly connect the Web Server Module to the internet. Please contact your local distributor in this case. 4
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project