Mitsubishi | QJ71WS96 | User manual | Web Server Module

Add to my manuals
2 Pages

advertisement

Mitsubishi | QJ71WS96 | User manual | Web Server Module | Manualzz
Outline dimension drawings
December 2002
(3) Monitoring events
The Web Server Module monitors the PLC CPU state according to the device value or time conditions, and saves the
event history.
It shows the saved event history data on the Web browser.
If necessary, it can send by e-mail when the event occurs.
New Product Release
Mitsubishi PLC
98
No. 186E
(2) The Web Sever Module monitors the
CPU and data according to the event
monitor settings.
Web Server Module
(1) The Web Server Module displays
the event history with the
event history monitor.
Tag data
monitor
Client
QJ71WS96 type
Time data
interval monitor
Tag data
Web Server Module
27.4
Internet
Event monitor settings
Event history monitor
Tag name
Element
name
Condition
Trigger
value
A process
Pressure
>=
120
A process Temperature
=
30
A process
>
200
Water level
90
CPU status
monitor
...
Event type :
Product list
Tag monitor
Status
Tag name
Element
name
Condition
Occurrence
A process
Pressure
>
Part name
02/07/01 12:55:10
Occurrence
A process
Temperature
>=
QJ71WS96 type Web Server Module
02/07/01 14:10:00
Occurrence
A process
Water level
=
The Web Server Module is now available to realize
remote monitoring to the Q Series!
...
Type
QJ71WS96
...
...
...
...
...
(1) User sets the event monitor with
the Web browser.
Date
02/07/01 09:00:00
Manuals
(4) If necessary, the Web Server
Module can send an e-mail
when event occurs.
Web Server Module
Manual name
Client
E-mail
Web Server Module User’s Manual (Hardware)
Web Server Module User’s Manual
Manual shipping style
IB/SH No.
Type code
Enclosed with product
IB-0800231
13JT97
Optional
SH-080320E
13JR58
Access the PLC via the internet
No Web server PC
Easy setting with Web browser
Various connections (ADSL, modem, LAN, etc.)
Data logging function
Event occurrence
Internet service provider
(Separate contract for services required)
Logging data
Tag data
Internet
Microsoft Windows and Microsoft Windows NT are registered trademarks of Microsoft Corporation in the United States and other countries.
Netscape is a registered trademark of Netscape Communications Corporation in the United States and other countries.
Ethernet is a registered trademark of Xerox Corporation.
Other company names and product names used in this document are trademarks or registered trademarks of the respective companies.
Internet service provider
(Separate contract for services required)
(4) Various connections
There are various connection methods to match the user’s network environment.
Web Server Module
Client
Country/Region
Sales office
Tel/Fax
MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Tel : +55-11-283-2423
AV. Paulista 1471, Conj. 308, Sao Paulo City, Sao Paulo State, Fax : +55-11-288-3047
Brazil
Taiwan
Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine,
Taiwan
Tel : +886-2-2299-2499
Fax : +886-2-2299-2509
Germany
Mitsubishi Electric Europe B.V. German Branch
Gothaer Strsse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
Fax : +49-2102-486-7170
Korea
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Herts., AL10 8XB,UK
Tel : +44-1707-276100
Fax : +44-1707-278695
HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg., 660-11,Deungchon-dong
Kangsec-ku, Seoul, Korea
Tel : +82-2-3660-9552
Fax : +82-2-3664-8372
U.K
Singapore
Italy
Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo - Ingr.2
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Tel : +39-039-6053344
Fax : +39-039-6053312
Mitsubishi Electric Asia Pte, Ltd.
307 ALEXANDRA ROAD #05-01/02,
MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943
Tel : +65-6473-2308
Fax : +65-6476-7439
Thailand
Spain
Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
Fax : +34-93-589-2948
F. A. Tech Co.,Ltd.
898/28,29,30 S.V.CITY BUILDING,OFFICE TOWER 2,FLOOR
17-18 RAMA 3
ROAD,BANGKPONGPANG,YANNAWA,BANGKOK 10120
Tel : +66-2-682-6522
Fax : +66-2-682-6020
France
Mitsubishi Electric Europe B.V. French Branch
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France
Tel : +33-1-5568-5568
Fax : +33-1-5568-5685
Indonesia
Tel : +62-21-663-0833
Fax : +62-21-663-0832
South Africa
Circuit Breaker Industries LTD.
Tripswitch Drive, Elandsfontein Gauteng, South Africa
Tel : +27-11-928-2000
Fax : +27-11-392-2354
P.T. Autoteknindo SUMBER MAKMUR
JL. MUARA KARANG SELATAN BLOK A UTARA NO.1 KAV.
NO.11 KAWASAN INDUSTRI/ PERGUDANGAN JAKARTA UTARA 14440
Hong Kong
Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric Road, North Point,
HongKong
Tel : +852-2887-8870
Fax : +852-2887-7984
India
Messung Systems Put,Ltd.
Tel : +91-20-712-2807
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,PUNE- Fax : +91-20-712-0391
411026
Ryoden Automation Shanghai Ltd.
3F Block5 Building Automation Instrumentation Plaza 103 Cao
Bao Rd. Shanghai 200233 China
Tel : +86-21-6475-3228
Fax : +86-21-6484-6996
Country/Region
Sales office
Brazil
ADSL
Analog modem
LAN
* Obtain internet service for internet connection.
* Obtain comunication devices and cables.
China
Tel/Fax
Australia
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116,
Australia
Tel : +61-2-9684-7777
Fax : +61-2-9684-7245
Device
data
Web Server Module
MELSECNET/H, etc.
HEAD OFFICE: 1-8-12, OFFICE TOWER Z 14F HARUMI GHUO-KU 104-6212, JAPAN
NAGOYA WORKES: 1-14, YADAMINAMI5, HIGASIKU, NAGOYA, JAPAN
2
0212 (MDOC)
Specifications subject to change without notice.
Printed in Japan on recycled paper.
Modem
* Prepared by user
Control and monitor the PLC equipment using
the Web browser.
Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO14001
(standards for environmental management systems) and ISO9001(standards for
quality assurance managememt systems)
List of functions
Features
(1) Gathering tag data
Function
The Web Server Module gathers tag data that is a group of device data of PLC CPU sitting on the network,
and it shows collected tag data on the Web browser by specifying the tag name.
Monitor functions
Web Server Module
(3) The Web Server Module
shows specified tag data.
(2) The Web Server Module
collect device data in tag
units according to the
tag settings.
Client
Internet
CPU1:
Monitors the device value.
Tag data monitor
Monitors the tag data.
Number of simultaneous connectable nodes
5
Logging monitor
Monitors the logging data.
HTTP version
1.0
Event monitor
Monitors the event history.
PLC diagnosis monitor
Monitors the operation state of the PLC CPU.
User area capacity
Standard ROM: Maximum 5MB
When Compact FlashTM card is used: Maximum 512MB
(Including the home page capacity and logging capacity)
User authentication
Account Number: Maximum 16
(User ID: 1 to 20 characters, Password: 8 to 14 characters)
Value
(Component name)
D100
100
Pressure
D200
20.3
Temperature
D300
9
Water level
D400
70
Humidity
Tag setting
Tag data monitor
Tag name :
Tag name :
O1: A process
O1: A process
Component name
CPU name
Device
Component name
Value
Pressure
CPU1
D100
Pressure
100
Temperature
CPU1
D200
Temperature
20.3
Water level
CPU1
D300
Water level
9
Humidity
CPU1
D400
Humidity
70
Production quantity
CPU2
D10
Production quantity
1280
Item
Registers and collects a group of device data from each PLC CPU on the network as a tag, and displays it on the
browser.
Logging function
Collects the tag data collected in chronological order and displays it on the browser.
Event monitor function
Monitors the tag data, time interval and CPU status, and displays the history of events on the browser.
Access log
Provided
Sends e-mail.
Sends e-mail from PLC CPU
Sends e-mail with event monitor function
Parts for creating user screen
E-mail function
Java applet: 6 types
(File supplied as standard with the Web Server Module can be used (Creating by users is not possible))
Operation check browser
Internet Explorer 5.5/6.0 Microsoft Corporation (refer to Remarks (3))
Java VM version: Build number 3309 or later (refer to Remarks (2))
FTP function
Transfers files between the Web Server Module and clients.
FTP server function
FTP client function
Subject
Maximum 373 words
Main text
Maximum 960 words
Attached file
Maximum 256 words (512k bytes)
Attached file format
MIME Format
MIME version
1.0
Attached file Data
CSV format File name: XXXX.csv (1 to 8 characters)
Division
Attached files cannot be divided
Encryption
None
Compression
None
Communication with mail server
SMTP (send server) port number = 25
Operation check mailer
Internet Explorer 5.5/6.0 Microsoft Corporation (Outlook Express 5.5/6.0)
Server function
Provided
Number of simultaneous connectable nodes
10
Client function
Provided (PUT only)
Tag
Tag number: Maximum 64, Component number: Maximum 64
Logging
Loging number: Maximum 64, Lines number (Number of records): Maximum 10000 lines
Monitor interval
1 to 32767 seconds
Browser
Access log function
Displays the access log to the Web Server Module on the browser.
Address notification function
Notifies the Web Server Module’s address to clients.
Data management function
Backs up and restores the standard ROM, and formats the compact flash card.
Diagnosis function
Checks itself and connection.
User screen creation function
Creates the user’s original monitor screen using parts (Java applets) supplied by Mitsubishi.
Value
(Component name)
D10
1280
Production quantity
(1) User sets the tag and tag components
with the Web browser.
FTP client
Item
Specifications
Interface (*1)
Data transmission speed
10BASE-T/
100BASE-TX
section
10BASE-T
100BASE-TX
10Mbps
100Mbps
Maximum number of nodes/connection
Cascade connection: Maximum 4 stages
(2) The Web Server Module is
gathering tag data according
to the logging settings.
RS-232 compliant (D-Sub 9 pin)
Interface
The tag data are saved successively.
The saved logging data are shown on the Web browser by specifying the logging name.
Communication method
Full-duplex transmission
Synchronization method
Start-stop synchronization
Transmission speed (bps)
9600,19200,38400,57600,115200
Maximum 15m
Transmission distance
(3) The Web server module
shows the logging data.
Client
RS-232 section
Data format
Start bit
1
Data bit
8
Logging data
Logging setting
Tag name
Flow control (RS/CS control) is available
Recommended cable
7/0.127 P HRV-SV, Outer diameter: 8.5mm or more
(Oki Electric Cable Co., Ltd.; Number of pairs indicated in section)
A process
Interval specification (300 [seconds])
B process
Interval specification (60 [seconds])
C process
Time specification (05:00:00)
(1) User sets the logging conditions
with the Web browser.
Logging name :
Display form :
A process
List display (*)
Compact flash card
section
3.3V
Supplied power voltage
One card
Number of mountable cards
Date
Pressure
Temperature
02/07/01 09:00:00
90
20.3
9
Number of occupied input/output points
02/07/01 09:05:00
97
20.5
7
Number of writing times to standard ROM (flash ROM)
02/07/01 09:10:00
101
20.4
8
5VDC internal current consumption
02/07/01 09:15:00
100
20.4
10
External dimensions
02/07/01 09:20:00
103
20.2
13
Weight
Noise withstand level, withstand voltage, insulation resistance
(1) Compact flash card
The type 1 storage card that complies with Compact FlashTM specifications can be used with this Web Server Module.
Only one compact flash card can be mounted on the Web Server Module.
The specifications of the analog modem and ADSL modem that can be used with the Web Server Module are
shown below.
Function
Analog modem
5%
TYPE 1 card
Card size
Water
level
* The logging data is displayed as a list or graph.
1
9-pin D-sub (male) screw fixed type
External wiring appricable connector
Logging monitor
Logging interval
None
Transmission control
Internet
Connection configuration devices
(2) Analog modem, ADSL modem
1
Stop bit
Parity check
Tag data
Cascade connection: Maximum 2 stages
100m
Automatic negotiation function compatible (Automatic recognition of 10BASE-T/100BASE-TX)
Support function
(2) Logging the tag data
Data collection
Base band
Transmission method
Maximum segment length (*2)
Web Server Module
E-mail
FTP server
(1) Communication and I/F specifications
Device
Web server
Performance specifications
CPU2:
Specifications
Tag function
Tag data
Device
(2) Software specifications
Details
Device monitor
According to power supply module at station where Web Server Module is mounted
32-points per slot (I/O assignment: 32 intelligent points)
Maximum 100,000 times to same area
Details
Web Server Module interface
Compatible with Web Server Module’s CH2 (RS-232) transmission speed (*1)
Data communication control command
Compatible with Hayes AT commands
DR signal control
Capable of turning only DR (DSR) signal ON independently
Web server unit interface
Interface compatible with Web Server Module’s CH1 (10BASE-T/100BASE-TX) transmission speed
Protocol (*2)
PPPoE (PPP over Ethernet)
PPPoA (PPP over ATM)
*1. Refer to section (1) in the performance specifications for details on the Web Server Module CH1/CH2 transmission speed.
*2. Obtain an internet service provider and static IP address to use the PPPoE router type ADSL modem or PPPoA type ADSL modem.
Notify the client of the global IP address (static IP address) assigned to the ADSL modem when connecting the Web Server Module to the network with the ADSL modem.
0.65A
98 (3.86 in.) (H) x 27.4 (1.08 in.) (W) x 90 (3.54 in.) (D) [mm]
0.17 kg (0.37 lb.)
*1. The Web Server Module automatically switches between the 10BASE-T/100BASE-TX according to connection.
*2. Length between hub and node.
3
Precautions for internet connection infrastructure environment
Note that depending on the internet connection infrastructure environment in each country and region, you may not
be able to correctly connect the Web Server Module to the internet. Please contact your local distributor in this case.
4

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement