User's manual | Robertshaw 9700i User`s manual


Add to my manuals
12 Pages

advertisement

User's manual | Robertshaw 9700i User`s manual | Manualzz
9600
®
INTEGRATED COMFORT SOLUTIONS™
DIGITAL
PROGRAMMABLE
THERMOSTAT
E
G
ELECTRIC
GAS
5 - 2 Day Programmable
1 Heat / 1 Cool
User’s Manual
Quick Start
Installation and
Programming
WA
110-653B
RRANTY
Installation Guide
IMPORTANT SAFETY INFORMATION WARNING:
•
Always turn off power at the main power source by unscrewing
fuse or switching circuit breaker to the off position before installing,
removing, cleaning or servicing thermostat.
•
Read all of the information in this manual before installing or
programming this thermostat.
•
This is a 24V AC low-voltage thermostat. Do not install on voltages
higher than 30V AC.
•
All wiring must conform to local and national building and electrical
codes and ordinances.
•
Do not short (jumper) across terminals on the gas valve or at the
system control to test installation. This will damage the thermostat
and void the warranty.
1
Features
• Four setpoints for weekday programming—two setpoints for
weekend comfort.
• Two “AA” ENERGIZER brand batteries retain program memory, even
during power outages.
• Low battery indicator.
• Fahrenheit/Celsius display option.
• Programmable from 45°F (4°C) to 90°F (32°C).
• Accuracy within ± 1 degree.
• Adjustable temperature differential: 1-3 degrees.
• Maintains summer and winter programming.
• Low temperature freeze protection. While in heat mode, thermostat
will mechanically turn on heat if temperature drops to 40°F (4°C) even if batteries are missing or drained.
• Automatic heating shutdown if temperature exceeds 90°F (32°C).
Replacing Existing Thermostat
1. Turn off power to heating and cooling system.
2. Remove cover of old thermostat to expose wires. Do not
disconnect wires. (Fig. 1)
3. Label wires per Table 1.
Table 1
Old Label
New Label
Description
M, 4, RH, R5 or R
RH
Heat Transformer,
hot side
V or RC
RC
Cooling Transformer, hot
side
Y or Y6
Y
Cooling control
H, W or 4
W
Heating control
F or G
G
C*
Fan control relay
Y or None
*NOTE: ON
SOME OLDER MODELS, THE
C
TERMINAL CAN BE EITHER THE COOLING
CONTROL OR THE COMMON SIDE OF THE TRANSFORMER.
DIAGRAM TO VERIFY
C
Either cooling control or
common side of transformer
CHECK
FURNACE WIRING
TERMINAL. IF IT IS THE COMMON SIDE OF THE
TRANSFORMER, CAP THE WIRE AND TUCK INTO THE WALL. IF IT IS THE COOLING
CONTROL, CONNECT TO THE
Y
TERMINAL.
4. After labeling wires, remove wires from terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how to
install thermostat.
2
Figure 1
Installing Item 9600 Thermostat
4-5 FEET
DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS,
DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION
THESE PLACES WILL AFFECT THERMOSTAT OPERATION.
NOTE: FOR
NEW INSTALLATIONS, MOUNT THERMOSTAT ON INSIDE WALL,
ABOVE THE FLOOR.
1. Turn power off to the heating and cooling systems.
2. Place COOL-OFF-HEAT In OFF position.
COOL-OFF-HEAT
PROG
>
MAN
>
IN
AT
SET PROG/MAN
COOL-OFF-HEAT
AUTO - ON
AUTO - ON
3. Place
AUTO–ON switch
Into AUTO position.
4. Remove the cover using a coin
or screwdriver.
Figure 2
5. Place thermostat against the wall at desired location. Make sure
wires will feed through opening on base of thermostat.
6. Mark placement of mounting holes. See Fig. 3. Set base aside.
3
Figure 3
MOUNTING HOLES
AM
PM
PROG
MORN DAY EVE NITE
CHANGE
SET
RH
RC
MAN
W
Y
AUTO/MAN
G
COOL OFF HEAT
Elec
Gas
FAN AUTO ON
7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic
anchors do not require a drilled hole for drywall.
8. Tap plastic anchors into the wall.
9. Align base with plastic anchors and feed wires through opening.
See Fig 4.
Figure 4
AM
PM
PROG
RH
RC
MORN DAY EVE NITE
CHANGE
SET
MAN
W
Y
AUTO/MAN
G
COOL OFF HEAT
Elec
Gas
FAN AUTO ON
10. Secure base to wall with supplied screws.
11. Connect wires to terminal strip. Refer to wiring diagrams on other
side of this sheet. Make sure wire connections are secure.
12. Place fan option switch into either the “ELEC” or “GAS” position
depending upon the type of furnace. Refer to Figure 5.
Figure 5
AM
PM
PROG
RH
RC
MORN DAY EVE NITE
CHANGE
SET
MAN
W
Y
AUTO/MAN
G
COOL OFF HEAT
4
Elec
Gas
FAN AUTO ON
FAN
OPTION
SWITCH
Controls
fan delay.
13. Install two “AA” ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries
with positive (+) battery terminals in the battery compartment. The
display will show as follows:
14. Replace cover onto thermostat by snapping into place.
15. Turn on power to system . Test thermostat as described in the
following section.
Programming Guide
Set Time of Day, Day of Week,
Temperature Differential
1. Press & Hold SET. Press PROG/MAN
Release simultaneously.
SET PROG/MAN
PROG
COOL-OFF-HEAT
AUTO - ON
>
SET PROG/MAN
>
>
>
MAN
Press ✞ or ✟ to change
Time of Day.
>
SET P
Press
>
2. Press
To Change
Day of Week
5
1=MO
2=TU
3=WE
4=TH
5=FR
6=SA
7=SU
>
Press
>
3. Press
SET P
To change
Temperature Differential*
*THE TEMPERATURE DIFFERENTIAL
IS
FACTORY
PRESET AT
1°. THIS
MEANS
THAT WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM
THE TEMPERATURE SETTING, THE SYSTEM WILL TURN ON. IF THE SYSTEM TURNS
ON TOO OFTEN, INCREASE THE TEMPERATURE DIFFERENTIAL.
Changing Fahrenheit (F) to Celsius (C)
SET P
>
Press
>
Press and Hold SET
Release both simultaneously.
Setting Daily Programming
1. Place COOL-OFF-HEAT switch
in COOL position.
COOL-OFF-HEAT
PROG
>
>
MAN
SET PROG/MAN
COOL-OFF-HEAT
AUTO - ON
SET PR
3. Press ✞ or ✟ to change
MORN time
6
>
>
2. Press SET.
4. Press SET.
SET PR
PROG
COOL-OFF-HEAT
AUTO - ON
>
SET PROG/MAN
>
>
>
MAN
5. Press ✞ or ✟ to change
MORN temperature.
6. Repeat Steps 2-5 for DAY, EVE, and NITE.
COOL-OFF-HEAT
7. Shift COOL-OFF-HEAT switch to
HEAT position.
8. Repeat steps 2-6 to program HEAT (winter) settings.
NOTE: BOTH SUMMER AND WINTER PROGRAMS USE THE SAME TIME SETTINGS.
Your thermostat is now programmed for summer and winter operation.
It will follow the four settings (MORN, DAY, EVE, NITE) for weekday operation and two settings (MORN and NITE) for weekend operation. Adjust the
program at any time by following the steps as outlined above.
Begin Programmed Operation
1. Place
AUTO–ON switch
Into AUTO.
AUTO - ON
PROG
>
>
MAN
SET PROG/MAN
COOL-OFF-HEAT
AUTO - ON
COOL-OFF-HEAT
SUMMER
2. Place COOL-OFF-HEAT switch
Into COOL or HEAT
Depending upon the season.
COOL-OFF-HEAT
3. Press PROG/MAN button
until indicator is in PROG position.
WINTER
ET PROG/MAN
PROG
>
>
MAN
SET PROG/MAN
COOL-OFF-HEAT
AUTO - ON
PROG
MAN
7
Temporary Program Override
To temporarily increase or decrease temperature
>
>
Press ✞ or ✟
PROG
>
>
MAN
SET PROG/MAN
COOL-OFF-HEAT
AUTO - ON
The Thermostat will automatically return
to the program at the next scheduled
setting change.
Manual Operation
1. Press PROG/MAN until indicator is in MAN position.
PROG
MAN
>
>
T PROG/MAN
SET PROG/MAN
COOL-OFF-HEAT
PROG
AUTO - ON
>
2. Press ✞ or ✟ to adjust
temperature settings.
>
MAN
Reset
To Reset the thermostat to factory pre-programmed
conditions, press the reset button located directly
to the right of the display.
AM
PM
PROG
MORN DAY EVE NITE
CHANGE
SET
RH
RC
MAN
W
Y
AUTO/MAN
G
RESET
BUTTON
COOL OFF HEAT
8
Elec
Gas
FAN AUTO ON
To Test Thermostat
WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS
VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE
THE THERMOSTAT AND VOID YOUR WARRANTY.
CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW 50°F
(10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL
INJURY.
COOL-OFF-HEAT
1. Place the COOL-OFF-HEAT
switch into the COOL position
2. Press the ✞ button until the temperature
setting is at east 3 degrees below the room temperature. The
air conditioning system should turn on within a few seconds.
NOTE: THERE IS A BUILT IN 5-MINUTE DELAY ON BREAK FOR COMPRESSOR PROTECTION. A SECOND ATTEMPT TO TURN ON THE AIR CONDITIONING WILL RESULT IN A
5-MINUTE DELAY IN COMPRESSOR ACTIVATION.
COOL-OFF-HEAT
3. Put the COOL-OFF-HEAT switch into
the OFF position. The air conditioning
system should turn off. The fan may
continue to run for a short period of time.
COOL-OFF-HEAT
4. Put the COOL-OFF-HEAT switch
into the HEAT position.
5. Press the ✟ button until the temperature setting is at least
3 degrees above room temperature. The heating system should turn
on. The fan may not turn on immediately, depending upon the fan
delay built into the furnace.
COOL-OFF-HEAT
6. Put the COOL-OFF-HEAT switch
into the OFF position. The heating
system should turn off. Once again,
the fan may have a delay.
AUTO - ON
7. Put the
AUTO–ON switch
to the ON position. The blower
fan should turn on.
8. Put the
AUTO–ON switch
to the AUTO position. The blower
fan should turn off.
9
AUTO - ON
Troubleshooting
Symptom
Thermostat does not turn
on system
Remedy
Check Wiring
(See INSTALLATION)
Check fuse. Replace with 2 amp
Slo-Blo fuse if fuse has opened.
Thermostat turns on and off too
frequently.
Increase Temperature Differential
(See PROGRAMMING).
Display is blank, flashing or
constant “LO BAT.”
Replace batteries.
Weekend Program follows four
adjustment settings.
Verify that day of week is set
correctly. (See PROGRAMMING).
System fan does not operate
properly.
Move fan option switch to either
gas or electric, to match system.
(See INSTALLATION).
Time shown on display is not the
current time of day.
Change time of day setting.
(See PROGRAMMING).
Thermostat does not
follow program.
Thermostat in MANUAL mode.
(See PROGRAMMING).
Thermostat may not have been
programmed in HEAT or COOL
position. Verify program.
Check AM/PM indicators at time
of day and programmed time
changes. (See PROGRAMMING).
Verify program and day of week
is correct. (See PROGRAMMING).
If problems with thermostat cannot be solved, call:
Technical Support: (800) 445-8299
Monday-Friday 7:30-5:30 CST
For after hours service, a 24-hour
Automated Help Line is available
For warranty returns, send thermostat, shipping prepaid to:
MAPLE CHASE COMPANY
Warranty Department
2820 Thatcher Road
Downers Grove, IL 60515
10
Wiring Diagrams
The following is just a sample of the most common types of HVAC systems. Refer to your systems installation manual for wiring information.
HEAT ONLY
3-WIRE
SINGLE TRANSFORMER
HEAT/COOL
4-WIRE
SINGLE TRANSFORMER
Factory- Installed
jumper
Factory-Installed
jumper
RH
Transformer
RC
Hot
120 VAC
24 VAC
Heating
Control
W
Cooling
Control
Y
Fan
Control
G
T
H
E
R
M
O
S
T
A
T
RH
Transformer
Hot
120 VAC
RH
RC
24 VAC
Heating
Control
W
Y
G
NOTE: Remove factory
installed jumper
T
H
E
R
M
O
S
T
A
T
(HEATING)
Transformer
120 VAC
RH
24 VAC
RC
Hot
120 VAC
24 VAC
Heating
Control
W
Cooling
Control
Y
Fan
Control
G
T
H
E
R
M
O
S
T
A
T
G
T
H
E
R
M
O
S
T
A
T
COOL ONLY
3-WIRE
SINGLE TRANSFORMER
RH
Transformer
Hot
120 VAC
RC
24 VAC
W
HEAT/COOL
5-WIRE
TWO TRANSFORMER
Hot
W
Y
Fan
Control
NOTE: Remove factory
installed jumper
Hot
120 VAC
24 VAC
Heating
Control
HEAT ONLY
2-WIRE
SINGLE TRANSFORMER
Transformer
RC
NOTE: Cut center of
factory installed jumper
and bend back
NOTE: Both transformers
must be in phase.
(COOLING)
Transformer
11
Cooling
Control
Y
Fan
Control
G
T
H
E
R
M
O
S
T
A
T
FIVE-YEAR LIMITED WARRANTY
Maple Chase Company warrants to the original contractor installer or
to the original consumer user, each new Maple Chase thermostat to be
free from defects in materials and workmanship under normal use and
service for a period of five (5) years from date of purchase. This warranty
and our liability does not apply to batteries or the merchandise that has
been damaged, caused by misuse, neglect, mishandling, alterations,
improper installation, or use in a way other than in accordance with
Maple Chase Company recommendations and instructions.
Maple Chase Company agrees to repair or replace at its option any
thermostat under warranty provided it is returned within the warranty
period, postage prepaid, with proof of the date of purchase. Cost of thermostat removal or reinstallation is not the responsibility of Maple Chase
Company.
Repair or replacement as provided under this warranty is the exclusive
remedy of the consumer. Maple Chase Company shall not be liable for
any incidental or consequential damages for breach of any express or
implied warranty on this product, or under any other theory of liability.
Except to the extent prohibited by applicable law, any implied warranty of
merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty
lasts, so the above limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
Maple Chase Company
2820 Thatcher Road
Downers Grove, Illinois 60515
United States of America
©2000 Maple Chase Company
110-653B
12

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement