advertisement
▼
Scroll to page 2
of 12
9600 ® INTEGRATED COMFORT SOLUTIONS™ DIGITAL PROGRAMMABLE THERMOSTAT E G ELECTRIC GAS 5 - 2 Day Programmable 1 Heat / 1 Cool User’s Manual Quick Start Installation and Programming WA 110-653B RRANTY Installation Guide IMPORTANT SAFETY INFORMATION WARNING: • Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning or servicing thermostat. • Read all of the information in this manual before installing or programming this thermostat. • This is a 24V AC low-voltage thermostat. Do not install on voltages higher than 30V AC. • All wiring must conform to local and national building and electrical codes and ordinances. • Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty. 1 Features • Four setpoints for weekday programming—two setpoints for weekend comfort. • Two “AA” ENERGIZER brand batteries retain program memory, even during power outages. • Low battery indicator. • Fahrenheit/Celsius display option. • Programmable from 45°F (4°C) to 90°F (32°C). • Accuracy within ± 1 degree. • Adjustable temperature differential: 1-3 degrees. • Maintains summer and winter programming. • Low temperature freeze protection. While in heat mode, thermostat will mechanically turn on heat if temperature drops to 40°F (4°C) even if batteries are missing or drained. • Automatic heating shutdown if temperature exceeds 90°F (32°C). Replacing Existing Thermostat 1. Turn off power to heating and cooling system. 2. Remove cover of old thermostat to expose wires. Do not disconnect wires. (Fig. 1) 3. Label wires per Table 1. Table 1 Old Label New Label Description M, 4, RH, R5 or R RH Heat Transformer, hot side V or RC RC Cooling Transformer, hot side Y or Y6 Y Cooling control H, W or 4 W Heating control F or G G C* Fan control relay Y or None *NOTE: ON SOME OLDER MODELS, THE C TERMINAL CAN BE EITHER THE COOLING CONTROL OR THE COMMON SIDE OF THE TRANSFORMER. DIAGRAM TO VERIFY C Either cooling control or common side of transformer CHECK FURNACE WIRING TERMINAL. IF IT IS THE COMMON SIDE OF THE TRANSFORMER, CAP THE WIRE AND TUCK INTO THE WALL. IF IT IS THE COOLING CONTROL, CONNECT TO THE Y TERMINAL. 4. After labeling wires, remove wires from terminals. 5. Remove existing thermostat base from wall. 6. Refer to the following section for instructions on how to install thermostat. 2 Figure 1 Installing Item 9600 Thermostat 4-5 FEET DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS, DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION THESE PLACES WILL AFFECT THERMOSTAT OPERATION. NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON INSIDE WALL, ABOVE THE FLOOR. 1. Turn power off to the heating and cooling systems. 2. Place COOL-OFF-HEAT In OFF position. COOL-OFF-HEAT PROG > MAN > IN AT SET PROG/MAN COOL-OFF-HEAT AUTO - ON AUTO - ON 3. Place AUTO–ON switch Into AUTO position. 4. Remove the cover using a coin or screwdriver. Figure 2 5. Place thermostat against the wall at desired location. Make sure wires will feed through opening on base of thermostat. 6. Mark placement of mounting holes. See Fig. 3. Set base aside. 3 Figure 3 MOUNTING HOLES AM PM PROG MORN DAY EVE NITE CHANGE SET RH RC MAN W Y AUTO/MAN G COOL OFF HEAT Elec Gas FAN AUTO ON 7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic anchors do not require a drilled hole for drywall. 8. Tap plastic anchors into the wall. 9. Align base with plastic anchors and feed wires through opening. See Fig 4. Figure 4 AM PM PROG RH RC MORN DAY EVE NITE CHANGE SET MAN W Y AUTO/MAN G COOL OFF HEAT Elec Gas FAN AUTO ON 10. Secure base to wall with supplied screws. 11. Connect wires to terminal strip. Refer to wiring diagrams on other side of this sheet. Make sure wire connections are secure. 12. Place fan option switch into either the “ELEC” or “GAS” position depending upon the type of furnace. Refer to Figure 5. Figure 5 AM PM PROG RH RC MORN DAY EVE NITE CHANGE SET MAN W Y AUTO/MAN G COOL OFF HEAT 4 Elec Gas FAN AUTO ON FAN OPTION SWITCH Controls fan delay. 13. Install two “AA” ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. The display will show as follows: 14. Replace cover onto thermostat by snapping into place. 15. Turn on power to system . Test thermostat as described in the following section. Programming Guide Set Time of Day, Day of Week, Temperature Differential 1. Press & Hold SET. Press PROG/MAN Release simultaneously. SET PROG/MAN PROG COOL-OFF-HEAT AUTO - ON > SET PROG/MAN > > > MAN Press ✞ or ✟ to change Time of Day. > SET P Press > 2. Press To Change Day of Week 5 1=MO 2=TU 3=WE 4=TH 5=FR 6=SA 7=SU > Press > 3. Press SET P To change Temperature Differential* *THE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 1°. THIS MEANS THAT WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM THE TEMPERATURE SETTING, THE SYSTEM WILL TURN ON. IF THE SYSTEM TURNS ON TOO OFTEN, INCREASE THE TEMPERATURE DIFFERENTIAL. Changing Fahrenheit (F) to Celsius (C) SET P > Press > Press and Hold SET Release both simultaneously. Setting Daily Programming 1. Place COOL-OFF-HEAT switch in COOL position. COOL-OFF-HEAT PROG > > MAN SET PROG/MAN COOL-OFF-HEAT AUTO - ON SET PR 3. Press ✞ or ✟ to change MORN time 6 > > 2. Press SET. 4. Press SET. SET PR PROG COOL-OFF-HEAT AUTO - ON > SET PROG/MAN > > > MAN 5. Press ✞ or ✟ to change MORN temperature. 6. Repeat Steps 2-5 for DAY, EVE, and NITE. COOL-OFF-HEAT 7. Shift COOL-OFF-HEAT switch to HEAT position. 8. Repeat steps 2-6 to program HEAT (winter) settings. NOTE: BOTH SUMMER AND WINTER PROGRAMS USE THE SAME TIME SETTINGS. Your thermostat is now programmed for summer and winter operation. It will follow the four settings (MORN, DAY, EVE, NITE) for weekday operation and two settings (MORN and NITE) for weekend operation. Adjust the program at any time by following the steps as outlined above. Begin Programmed Operation 1. Place AUTO–ON switch Into AUTO. AUTO - ON PROG > > MAN SET PROG/MAN COOL-OFF-HEAT AUTO - ON COOL-OFF-HEAT SUMMER 2. Place COOL-OFF-HEAT switch Into COOL or HEAT Depending upon the season. COOL-OFF-HEAT 3. Press PROG/MAN button until indicator is in PROG position. WINTER ET PROG/MAN PROG > > MAN SET PROG/MAN COOL-OFF-HEAT AUTO - ON PROG MAN 7 Temporary Program Override To temporarily increase or decrease temperature > > Press ✞ or ✟ PROG > > MAN SET PROG/MAN COOL-OFF-HEAT AUTO - ON The Thermostat will automatically return to the program at the next scheduled setting change. Manual Operation 1. Press PROG/MAN until indicator is in MAN position. PROG MAN > > T PROG/MAN SET PROG/MAN COOL-OFF-HEAT PROG AUTO - ON > 2. Press ✞ or ✟ to adjust temperature settings. > MAN Reset To Reset the thermostat to factory pre-programmed conditions, press the reset button located directly to the right of the display. AM PM PROG MORN DAY EVE NITE CHANGE SET RH RC MAN W Y AUTO/MAN G RESET BUTTON COOL OFF HEAT 8 Elec Gas FAN AUTO ON To Test Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY. CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY. COOL-OFF-HEAT 1. Place the COOL-OFF-HEAT switch into the COOL position 2. Press the ✞ button until the temperature setting is at east 3 degrees below the room temperature. The air conditioning system should turn on within a few seconds. NOTE: THERE IS A BUILT IN 5-MINUTE DELAY ON BREAK FOR COMPRESSOR PROTECTION. A SECOND ATTEMPT TO TURN ON THE AIR CONDITIONING WILL RESULT IN A 5-MINUTE DELAY IN COMPRESSOR ACTIVATION. COOL-OFF-HEAT 3. Put the COOL-OFF-HEAT switch into the OFF position. The air conditioning system should turn off. The fan may continue to run for a short period of time. COOL-OFF-HEAT 4. Put the COOL-OFF-HEAT switch into the HEAT position. 5. Press the ✟ button until the temperature setting is at least 3 degrees above room temperature. The heating system should turn on. The fan may not turn on immediately, depending upon the fan delay built into the furnace. COOL-OFF-HEAT 6. Put the COOL-OFF-HEAT switch into the OFF position. The heating system should turn off. Once again, the fan may have a delay. AUTO - ON 7. Put the AUTO–ON switch to the ON position. The blower fan should turn on. 8. Put the AUTO–ON switch to the AUTO position. The blower fan should turn off. 9 AUTO - ON Troubleshooting Symptom Thermostat does not turn on system Remedy Check Wiring (See INSTALLATION) Check fuse. Replace with 2 amp Slo-Blo fuse if fuse has opened. Thermostat turns on and off too frequently. Increase Temperature Differential (See PROGRAMMING). Display is blank, flashing or constant “LO BAT.” Replace batteries. Weekend Program follows four adjustment settings. Verify that day of week is set correctly. (See PROGRAMMING). System fan does not operate properly. Move fan option switch to either gas or electric, to match system. (See INSTALLATION). Time shown on display is not the current time of day. Change time of day setting. (See PROGRAMMING). Thermostat does not follow program. Thermostat in MANUAL mode. (See PROGRAMMING). Thermostat may not have been programmed in HEAT or COOL position. Verify program. Check AM/PM indicators at time of day and programmed time changes. (See PROGRAMMING). Verify program and day of week is correct. (See PROGRAMMING). If problems with thermostat cannot be solved, call: Technical Support: (800) 445-8299 Monday-Friday 7:30-5:30 CST For after hours service, a 24-hour Automated Help Line is available For warranty returns, send thermostat, shipping prepaid to: MAPLE CHASE COMPANY Warranty Department 2820 Thatcher Road Downers Grove, IL 60515 10 Wiring Diagrams The following is just a sample of the most common types of HVAC systems. Refer to your systems installation manual for wiring information. HEAT ONLY 3-WIRE SINGLE TRANSFORMER HEAT/COOL 4-WIRE SINGLE TRANSFORMER Factory- Installed jumper Factory-Installed jumper RH Transformer RC Hot 120 VAC 24 VAC Heating Control W Cooling Control Y Fan Control G T H E R M O S T A T RH Transformer Hot 120 VAC RH RC 24 VAC Heating Control W Y G NOTE: Remove factory installed jumper T H E R M O S T A T (HEATING) Transformer 120 VAC RH 24 VAC RC Hot 120 VAC 24 VAC Heating Control W Cooling Control Y Fan Control G T H E R M O S T A T G T H E R M O S T A T COOL ONLY 3-WIRE SINGLE TRANSFORMER RH Transformer Hot 120 VAC RC 24 VAC W HEAT/COOL 5-WIRE TWO TRANSFORMER Hot W Y Fan Control NOTE: Remove factory installed jumper Hot 120 VAC 24 VAC Heating Control HEAT ONLY 2-WIRE SINGLE TRANSFORMER Transformer RC NOTE: Cut center of factory installed jumper and bend back NOTE: Both transformers must be in phase. (COOLING) Transformer 11 Cooling Control Y Fan Control G T H E R M O S T A T FIVE-YEAR LIMITED WARRANTY Maple Chase Company warrants to the original contractor installer or to the original consumer user, each new Maple Chase thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase. This warranty and our liability does not apply to batteries or the merchandise that has been damaged, caused by misuse, neglect, mishandling, alterations, improper installation, or use in a way other than in accordance with Maple Chase Company recommendations and instructions. Maple Chase Company agrees to repair or replace at its option any thermostat under warranty provided it is returned within the warranty period, postage prepaid, with proof of the date of purchase. Cost of thermostat removal or reinstallation is not the responsibility of Maple Chase Company. Repair or replacement as provided under this warranty is the exclusive remedy of the consumer. Maple Chase Company shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, or under any other theory of liability. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Maple Chase Company 2820 Thatcher Road Downers Grove, Illinois 60515 United States of America ©2000 Maple Chase Company 110-653B 12
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement