3 ~ 50Hz ZUG OC 200D 132/6 AW 540

ZUG OC 200D 132/6 AW 540 Technical sheet
3 ~ 50Hz
ZUG OC 200D 132/6 AW 540
60
®
50
132/6 - 54
0
132/6 - 52
0
H [m]
40
132/6 - 48
0
132/6 - 45
132/6 - 430
0
132/6 420
132/6 - 40
0
30
20
132/6 - 510
132/6 - 500
10
0
0
50
LEGEND
0
100
150
200
250
500
300
350
1000
400
450 Q [l/s]
1500
Q [m3/h]
Performance curve relative to selected pump
Motor power (kW)
Poles
Alternative performance curves available with the same motor and different nominal standard impeller diameter
11/2 - 170 Nominal impeller diameter (mm)
Performance curves not recommended or available with different motor size
ZENIT UNIQA submersible electric pumps. Designed for heavy-duty professional applications, they are used in civil and industrial wastewater treatment plants, lifting
sewage, pumping industrial sludges and rainwater containing solids, and recycling raw or activated sludges and biological liquids.
ZENIT UNIQA series motors are designed with the aim of achieving the Premium (IE3) efficiency class according to EN 60034-30.
The entire range is available in the “dry” version, which requires no external liquid inputs and allows the pump to operate continually (S1 class) even if partially submerged or installed in a dry chamber. Not standard diameters ara available for optimal performance on the specific duty point.
Hydraulics
Standard construction features
Impeller
Open three channel with anti-clogging system
Max. hydraulic efficiency [% ]
81
Nominal impeller diameter [mm]
540
Blade number
3
Free passage [mm]
90
Discharge
DN 200
Suction
DN 250
Discharge orientation
H (Horizontal)
400
50
3
6
989
132
138,4
273,5
1275
1406
2960
68
H
star-delta
IE3
Standard
Grey cast iron EN-GJL 250
Stainless steel AISI 431
NBR
Stainless steel A2-70
Grey cast iron EN-GJL 250
Grey cast iron EN-GJL 250
Optional
AISI 329-630 / NITRONIC 50
VITON
Stainless steel A4-80
AISI 316/AISI 329 Duplex
AISI 316/AISI 329 Duplex/Br-Al
Accessories and variants
η%
95,4
95,9
95
Operating limits
www.zenit.com
Wet (W) Dry use must be agreed with Zenit
Construction materials
Case
Shaft
Cooling jacket
Gaskets
Screws
Hydraulic
Impeller
Tolerances according to EN 60034-1
Max. ambient temperature [°C]
Density treated liquid [kg/m3]
Max. immersion depth [m]
pH treated liquid
Max. start per hour (equally distributed)
Noise level [dB(A)]
1891
2 x S1RN8-F 4G35, 1 x S1RN8-F 7G1,5 + 3x1
10
Epoxy bicomponent 120 µm
N.2 in silicon carbide (SiC) in oil chamber
Bimetallic thermal sensors (150°C)
Double water presence probe
(mechanical seals and motor) - 1 signal
Wet/dry use
Motor
Nominal voltage Vn [V]
Nominal frequency f [Hz]
Phases
Poles
Speed [rpm]
Outcoming nominal power P2 [kW]
Incoming power P1 [kW]
Nominal absorbed current In [A]
Nominal torque [Nm]
Starting current [A]
Starting torque [Nm]
IP motor
Insulation class
Start
Efficiency class
Load
cos φ
4/4
0,73
3/4
0,68
0,57
2/4
Weight [kg]
Cable
Cable length [m]
Painting
Mechanical seals
Thermal protection
Probe
40 (60 on request)
1100
20
6 ÷ 14
15
< 70
ATEX version for explosive areas
Dry use
Feeding
Start
Drilling discharge flange (*)
Drilling suction flange (*)
Thermal protection (optional)
Vibrations sensors
Probe water in motor case
Cable
Cable length on request [m]
Zinc anodes
Painting and coating
Available on request
On request
VFD - 60Hz
DOL/Soft-start
UNI PN10/UNI PN16/ANSI 150RF
UNI PN10/UNI PN16/ANSI 150RF
PTC / PT100 Thermistor
Available on request
Available on request
NSSHÖU- O/J, EMC
20 / 30 / 40 / 50
Available on request
Epoxy bicomponent 400 µm.
(Different kind available on request)
(*) Flanges drilling are based on installation type (see following pages).
Additional flanges drilling available.
Rev. 0 - 13/02/2014
All data shown are not binding. Zenit reserves the right to change data and dimensions without notice.
ZUG OC 200D 132/6 AW 540 Technical sheet
3 ~ 50Hz
Performances
60
50
H [m]
40
30
20
10
0
0
50
100
0
150
200
250
500
300
350
450 Q [l/s]
400
1000
1500
Q [m3/h]
140
P2 [kW]
P1 [kW]
120
100
80
60
40
20
0
0
50
100
150
200
250
300
350
400
450 Q [l/s]
0
50
100
150
200
250
300
350
400
450 Q [l/s]
0,9
0,8
0,6
0,5
0,4
0,3
0,2
0,1
0,0
www.zenit.com
Characteristic curves according to UNI EN ISO 9906
η idr
η tot
0,7
All data shown are not binding. Zenit reserves the right to change data and dimensions without notice.
ZUG OC 200D 132/6 AW 540 Technical sheet
Installation types
Below the installation types for UNIQA series.
For each type, the connection drilling variants are specified in the following pages (see types). For the drilling connection, select the specific variant.
Additional flanges drilling available on request.
P installation type
The vertical or horizontal coupling device is fixed to the bottom of the
tank and the pump is lowered in with the aid of two guide pipes fitted
earlier, until the connection to the foot is completed.
The delivery pipe is fixed to the coupling device discharge.
This device makes routine checks, any maintenance work or replacement of the pump extremely easy, with no need to empty the tank.
S installation type
The electric pump, standing on its base, is connected to the flanged delivery pipe.
Otherwise, the electric pump can be connected to the delivery flexible pipe using a joint fixed to
the discharge.
This solution allows to move easily the electrical pump and it’s suggested for temporary installations.
T installation type
The submersible electric pump can be vertically installed in dry chambers.
In the vertical installation, the electric pump is mounted on a supporting bracket, to which the
intake line is connected.
For this installation type must be selected the correct pump version.
Z installation type
The submersible electric pump can be horizontally installed in dry chambers.
In the horizontal installation, the electric pump is fixed on a iron structure and the suction pipe is
directly connected to the suction flange of the pump.
For this installation type must be selected the correct pump version.
X installation type
Select this installation type when you don’t know the exact destination (suggested when you order
pump for stock).
www.zenit.com
All data shown are not binding. Zenit reserves the right to change data and dimensions without notice.
ZUG OC 200D 132/6 AW 540 Technical sheet
P installation type - Installation with vertical coupling device (DAC V)
PA: Installation type P with vertical coupling device. (DAC V coupling device must be ordered separately)
Drilling variant A without flushing valve
Discharge flange: DN200 PN10 EN1092-2 Tab.8
Suction: DN 250 undrilled
Flushing valve connection: not possible
PF: Installation type P Installation with vertical coupling device. (DAC V coupling device and FLX flushing valve must be ordered separately)
Drilling variant F with flushing valve (*)
Discharge flange: DN200 PN10 EN1092-2 Tab.8
Suction: DN 250 undrilled
Flushing valve connection: GAS 1½”
23
13
16
DAC-N 200/200V - 175 - 3"
9001.106
76
30
DN200 PN10
EN1092-2 Tab.8
159
116
174
Vertical coupling device
3"
FLX/G40
9004.001
DN 200 PN 10
EN 1092-2 Tab.8
45°
22
2060
Flushing valve
175
295
300
240
250
410
600
600
L
65
1075
650
(*) Verify the working range of the
flushing valve on operator’s manual
Dimensions in mm
www.zenit.com
250
L2: Pump body fully submerged
Minimum operating level for
discontinuous use for pumps in the
“WET” version (see operator’s manual)
124
L1: Pump fully submerged
Minimum operating level for continuous
use for pumps in the “WET” version
815
110
23
500
415
All data shown are not binding. Zenit reserves the right to change data and dimensions without notice.
ZUG OC 200D 132/6 AW 540 Technical sheet
S installation type - Installation with base plate (KBS)
SA: Installation type S with base plate. (KBS Base plate must be ordered separately)
Drilling variant A drilling variant without flushing valve
Discharge flange: DN200 PN10 EN1092-2 Tab.8
Flushing valve connection: not possible
SF: Installation type S with base plate. KBS Base plate and FLX flushing valve must be ordered separately
Drilling variant F with flushing valve (*)
Discharge flange: DN200 PN10 EN1092-2 Tab.8
Flushing valve connection: GAS 1½”
KBS V 4+4/610-697
9024.016
Base plate
2060
FLX/G40
9004.001
Flushing valve
DN 200 PN10
EN 1092-2 Tab.8
45°
375
170
720
22
L
295
990
300
250
300
(*) Verify the working range of the
flushing valve on operator’s manual
525
635
L2: Pump body fully submerged
Minimum operating level for
discontinuous use for pumps in the
“WET” version (see operator’s manual)
1270
L1: Pump fully submerged
Minimum operating level for continuous
use for pumps in the “WET” version
1050
24
495
655
Dimensions in mm
www.zenit.com
All data shown are not binding. Zenit reserves the right to change data and dimensions without notice.
ZUG OC 200D 132/6 AW 540 Technical sheet
X installation type
X
A
DAC/KBC
B
DAC/KBC/KBS
C
DAC/KBC/KBS/KBS-H
E
DAC/KBC/KBS/FLX
FLX drilling
KBS-H drilling
KBS drilling
Suction
flange
DN250 PN10
EN1092-2 Tab.8
Zenit
accessory
Discharge
flange
DN200 PN10
EN1092-2 Tab.8
Drilling
variant
Installation
type
Select a pump of this installation when you don’t know the exact destination (suggested when you order pump for stock).
DN 250 PN10 EN 1092-2 Tab.8
DAC-N 200/200V - 175 - 3"
9001.106
DN200 PN10
EN1092-2 Tab.8
Vertical coupling device
KBS V 4+4/610-697
9024.016
Base plate
2060
FLX/G40
9004.001
Flushing valve (*)
KBC 250/250 PN10
9008.011
DN250 PN10
EN1092-2 Tab.8
DN 200 PN10
EN 1092-2 Tab.8
DN250 PN10
EN1092-2 Tab.8
45°
170
10
KBS H ZU-M21 B1
9024.025
22
Inlet bend union
295
375
815
Horizontal support for dry installation
(*) Verify the working range of the
flushing valve on operator’s manual
Dimensions in mm
www.zenit.com
415