CC20 Series Tychem® Hood
TM
Simple, Effective, Ultra-Light
The CC20 Series Tychem® Hood provides a wide variety of simple, effective and economical
Head
Protection
options for on-the-job respiratory protection. The result is better protection, improved
productivity and greater comfort that combines to produce the best value on the market. These
hoods are available for use in a CC20 Series Airline Respirator configuration or PA20 Series
Powered Air Purifying Respirator configuration. Approved by NIOSH for use in Type C
applications, the CC20 Series is used in a wide variety of industries including:
• pharmaceutical manufacturing
• chemical and pesticide handling
• spray painting and coating operations
• nuclear operations
Respiratory
Protection
Proven Performance
In a 1996 study of hood-style respirators coordinated by the
Organization Resources Counselors (ORC), the Bullard CC20 hood
was surveyed to be the number one hood used in the
pharmaceutical industry.
Fire and Rescue
Safety
Thermal
Imaging
The most commonly used hoods were then used in a simulated
workplace protection factor study (SWPF). The Bullard CC20
hood was also the top-performing loose-fitting hood among a
variety of competitors. All measurements in the SWPF study
were above 150,000 resulting in a study Assigned
Protection Factor (APF) of 10,000!
For a summary of this research, call Bullard customer
service at 1-800-827-0423.
www.bullard.com
TM
Features and Benefits
Unique Air Delivery System
A patented neck cuff design helps maintain positive pressure inside the hood to aid in keeping
contaminants out. As air enters the hood, the inner collar inflates, providing a snug,
comfortable fit around the neck and continuous flow of air to the worker’s breathing zone.
Lightweight, Comfortable and Economical
The CC20 hood is lighter and more comfortable than tight-fitting full facepiece respirators.
Covering the entire head, face and neck, the CC20 hood provides splash/overspray protection
and makes clean-up quick and easy.
A wide angle lens offers the largest field of vision among Tychem hood-style respirators on the
market, optimizing worker productivity and safety.
Available in a variety of styles, the CC20 hood is constructed of either Tychem QC or Tychem SL
depending on the job application. Taped and sealed seams are also available to provided
additional protection for liquid penetration encountered on-the-job or during decontamination.
Reusable or Disposable
CC20 respirator hoods are durable enough to reuse, yet economical enough to discard after each
use, depending on the work application.
No Fit Testing
The CC20 hood does not
require fit testing nor
extensive recordkeeping. It
easily accommodates beards,
prescription eyewear or
safety glasses.
Powered Air or
Supplied Air
The CC20 hood is a available
for use as a supplied air
respirator (CC20 series) or
powered air respirator (PA20
series). A versatile hood
suitable for almost any
application.
CC20 Series Tychem® Hood
Hood style respirator does not require
fit testing and also allows for facial hair
and eyewear.
Replaceable snap-in suspension provides
ultimate comfort, and maintains the
field of vision during activities.
Wide angle lens offers the best
visibility in the industry.
Bullard CC20 and PA20 Respirators
Optional taped and sealed seams for
added protection.
Patented inflatable neck cuff design
provides superior, comfortable
protection, while delivering airflow
directly into the worker’s breathing
zone.
WARNING
This hood is only one component of a CC20 or PA20 respirator system. By itself, the
hood does not constitute a complete respirator. Read all instructions and warnings
before using this respirator hood. Improper respirator use could result in death or
serious injury, or may cause certain delayed lung diseases such as silicosis, pneumoconiosis or asbestosis. These diseases may cause death. If you have questions on
how to use this respirator, ask your employer.
Do not wear this respirator in any atmosphere immediately dangerous to life or health
(IDLH), or from which you cannot escape without the aid of the respirator. Do not wear
the PA20 respirator in any atmosphere containing less than 19.5% oxygen. If you are
not sure whether the atmosphere is IDLH or oxygen deficient, ask your employer.
Prior to each use of this respirator system, BE CERTAIN of the following:
FOR CC20 AIRLINE RESPIRATORS
AIR SUPPLY: Grade “D” Breathable Air, as described in the Compressed Gas
Association Commodity Specifications G7.1, must be continuously supplied to the pointof-attachment. The point-of-attachment is the point at which the air supply hose connects
to the air source. A pressure gauge attached to the air source is used to monitor the
pressure of air provided to the respirator wearer.
AIR SOURCE: Be sure to locate the source of compressed breathing air in a clean air
environment. Locate the air source far enough from your work site to ensure the air
remains contaminant free.
AIR PRESSURE at the point-of-attachment must be continuously maintained within the
pressure ranges certified on the NIOSH Approval Label that appears in the User Manual
supplied with the original factory packaged system and on the table on the reverse side
of this label.
NIOSH-APPROVED BULLARD AIR HOSE(S) must be used between the breathing
tube connection fitting on the wearer’s belt and the point-of-attachment to the air supply
system.
APPROVED FITTINGS must be used to connect hose lengths together. Total connected
hose lengths and number of sections must be within the ranges specified on the NIOSH
Approval Label and on the table on the reverse side of this label.
BELT AIR CONNECTION FITTINGS must be attached to your belt or the separate belt
supplied with the system to help keep the air supply hose from snagging, disconnecting
or pulling the hood off your head.
PROTECTION
HEAD – Only the respirator models 20TICH and 20SICH provides head protection when
used with a Bullard hard hat.
EARS – CC20 and PA20 respirators DO NOT provide hearing protection. Use properly
fitted earmuffs, earplugs or other protection when exposed to high noise levels.
EYES – CC20 and PA20 respirators DO NOT provide eye protection. Wear approved
safety glasses or goggles at all times.
TYCHEM® – There are uses, environments and chemicals for which this garment is not
suitable. It is the responsibility of the user and the employer to determine that this garment is appropriate for the intended use. This material should not be used around heat,
open flames, sparks or in any potentially flammable or explosive environment. This material will burn and will melt. DuPont Tychem spunbonded olefin apparel fabrics have
“Class 1- Normal Flammability” characteristics, as tested according to the Flammable
Fabrics Act. “Class 1” fabrics will burn and do not provide thermal protection if a fire or
explosion should occur
“Pony tail” tag on every
hood provides information
on replacement parts, user
guidelines, and required
pressures.
Optional inner bib
provides added
protection and some
cooling of the torso
Climate control options
allow the user to heat or
cool the incoming air by as
much as 30º F for comfort
and productivity.
CC20 Series Airline
Respirator Selection
TM
Select one of each of the following four components:
1
Respirator Hood
CC20 Series
respirator hoods
Material Choices
are made of tough,
and feature a
wide-angle lens
for excellent
peripheral vision.
Choose the hood
Tychem® QC - Tychem coated
with polyethylene provides
excellent splash protection
against many acids, bases
and other liquid chemicals.
Tychem® SL - (Used on SICN
hood only) Tychem coated
with SaranexTM 23-P provides
protection against an even
wider range of chemicals.
Inner Bib Style
Inner Bib Style
Basic Style
based materials
Long Outer Bib Style
With Tapered Seams
durable Tychem-
style that is best
suited for the
20TJN1, 20TPN3
work application.
20TICN1, 20TPCN3
20SICN1, 20TICSN1
20SICH2 , 20TICH2
1
Headband style with .020" lens, 2Hard hat style with .040" lens
Headband style with solvent resistant .010 mylar lens
3
2
Headband or Hard Hat
ANSI Z89.1-1986
Class A and B
requirements for
20TG
impact,
penetration and
dielectric
Standard headband with rear
slide adjustment
20RT
protection. All
3000R
Sure-Lock® ratchet headband
with rear adjustment knob
models come with
Cap-style hard
hat. Includes
Sure-Lock® ratchet headband
(ESRTSL)
3000
Model 5100R Hard Hat
The hard hat meets
Model 5100 Hard Hat
secure and stable.
Model 3000 Hard Hat
to keep the hood
Sure-Lock Ratchet
Headband
Standard Headband
band or hard hat
Model 3000R Hard Hat
Choose a head-
5100
Cap-style hard
hat. Includes
standard headband (ESULTRA)
Cap-style hard
hat.
Includes
standard headband (TG600)
5100R Cap-style hard
hat. Includes
standard headband (TGRT600)
Sportek browpad.
3
Breathing Tube Assembly with Optional Climate Control
Choose the breath-
For use with Ambient Air Pumps
For use with Breathing Air Compressors
ing tube assembly
appropriate for the
Constant Flow
Adjustable Flow
Adjustable Flow Climate Control Devices
Constant Flow
Adjustable Flow
able airflow and a
variety of quickdisconnect fittings.
Climate control
devices are available to cool or
warm incoming
air.
Cool Tube Assembly
Includes 1/4" quickdisconnect fitting
and belt.*
Hot/Cold Tube
Assembly
Includes 1/4" quickdisconnect fitting
and belt.*
Dual-Cool™ Assembly
Includes 1/4" quickdisconnect fitting and
belt. For use with a
cooling vest.*
Frigitron® 2000
Series
Breathing Tube
Assembly
Includes breathing
tube, 1/4" quick
disconnect fitting,
flow control valve and
belt.
V35 Series
Breathing Tube
Assembly
Includes breathing
tube, 1/4" quickdisconnect fitting
and belt.
DC5040 Series
stant or adjust-
HC2400 Series
available with con-
AC1000 Series
source. Assemblies
V40 Series
and breathing air
V30 Series
work application
Breathing Tube
Assembly
Includes breathing
tube, 1/2" quickdisconnect fitting
and belt.
*Can only be used with Bullard EDP30 or ADP20 pump.
4
Breathing Air Supply Hose
The breathing air
For use with Breathing Air Compressors
air source. Choose
the air supply
hose suitable for
the air source.
Available in
different lengths.
V10 Extension Hose Kits
in 25' (7.6 m), 50' (15.2 m)
and 100' (30.5 m) lengths.
V20 Series
assembly to the
V5 Series
breathing tube
For use with Ambient Air Pumps
V10 Series
connects the
V10 Series
supply hose
Starter Hose Kits
in 25' (7.6 m) length.
Starter/Extension Hose Kits
in 25' (7.6 m) and 50' (15.2
m) lengths.
Starter/Extension Hose Kits
in 50' (15.2 m) and 100'
(30.5 m) lengths.
Maximum total length = 50 ft.
Maximum total length = 300 ft.
Maximum total length = 300 ft.
Air Source
Breathing Air Compressor
Air Source
Bullard Free-Air®
Pump
Cool Tube Assembly*
Includes 1/2" quickdisconnect fitting and
belt.
PA20 Series Powered Air
Purifying Respirator System
TM
Select one of each of the following four components:
1
Respirator Hood
CC20 Series
respirator hoods
Material Choices
are made of tough,
for excellent
peripheral vision.
Choose the hood
Tychem® QC - Tychem coated
with polyethylene provides
excellent splash protection
against many acids, bases
and other liquid chemicals.
Tychem® SL - (Used on SICN
hood only) Tychem coated
with SaranexTM 23-P provides
protection against an even
wider range of chemicals.
Inner Bib Style
wide-angle lens
Inner Bib Style
and feature a
Basic Style
based materials
Long Outer Bib Style
With Tapered Seams
durable Tychem-
style that is best
suited for the
20TJN1, 20TPN3
work application.
20TICN1, 20TPCN3
20SICN1, 20TICSN1
20SICH2 , 20TICH2
1
Headband style with .020" lens, 2Hard hat style with .040" lens
Headband style with solvent resistant .010 mylar lens
3
2
Headband or Hard Hat
Class A and B
requirements for
impact,
20TG
penetration and
dielectric
Standard headband with rear
slide adjustment
Sure-Lock® ratchet headband
with rear adjustment knob
20RT
protection. All
3000R
models come with
Cap-style hard
hat. Includes
Sure-Lock® ratchet headband
(ESRTSL)
3000
Model 5100R Hard Hat
ANSI Z89.1-1986
Model 5100 Hard Hat
The hard hat meets
Model 3000 Hard Hat
secure and stable.
Model 3000R Hard Hat
to keep the hood
Sure-Lock Ratchet
Headband
band or hard hat
Standard Headband
Choose a head-
Cap-style hard
hat. Includes
standard headband (ESULTRA)
5100
Cap-style hard
hat.
Includes
standard headband (TG600)
5100R Cap-style hard
hat. Includes
standard headband (TGRT600)
Sportek browpad.
3
Blower Assembly
Choose a PA1 or
PA2 blower
include a breathing
tube with clamp,
filter and gasket,
comfort belt, and
airflow indicator.
PA20 Series
blower assemblies
PA20 Series
assembly. All
PA1 Blower Assembly
with 10-hour battery
and low voltage alarm.
PA2 Blower Assembly
with 6-hour battery.
4
PA20 Series
PA20 Series
PA20 Series
PA20 Series
Battery Chargers
PA1SMC Quick Charger
with trickle charge
capability.
PA1STC Standard
Charger
PA2SMC Quick Charger
with trickle charge
capability.
PA2STC Standard
Charger
PA20
PA20 Series
PA20 Series
PA20 Series
PA20 Series
PA20 Series
Replacement Parts
PA1FG3
3-pack of HEPA filters
with gaskets
PA1FGBP
36-pack of HEPA
filters with gaskets
PA1EB
Extension belt for
standard belt
PA1DB
All vinyl belt for
decontamination
PA1DEB
Extension belt for
decon belt
TM
Ordering Information
CATALOG
NUMBER
CATALOG
NUMBER
DESCRIPTION
DESCRIPTION
Respirator Hoods
Suplied Air Respirator Components
Basic Style Hoods
20TJN
Tychem QC, no suspension
20TPN
Tychem QC, no suspension, solvent resistant lens
Hood with inner bib, for use with headband
20TICN
Tychem QC, no suspension
20TPCN
Tychem QC, no suspension, solvent resistant lens
Hood with inner bib, for use with hard hat
20TICH
Tychem QC, hard hat not included
20SICH
Tychem SL, hard hat not included
Hood with inner bib and long outer bib, for use with
headband
20TICSN
Tychem QC, taped and sealed seams, no suspension
20SICN
Tychem SL, taped and sealed seams, no suspension
Accessory Item for All Hoods
20LCL
Mylar lens covers (25/pkg)
Breathing Tube
Headbands and Hard Hats
Adjustable Flow Breathing Tube Assembly for use with
Breathing Air Compressors (Schrader and Snap-Tite also
available)
V40
With 1/4" Industrial Interchange, steel (Hansen
compatible) quick-disconnect nipple
20TG
Standard headband
20RT
Sure-Lock® ratchet headband
3000
Hard hat with standard suspension, white
3000R
Hard hat with ratchet suspension, white
Accessories for Headbands and Hard Hats
ES-ULTRA Standard replacement suspension for 3000 hard hat
ESRTSL
Replacement ratchet suspension for 3000R hard hat
20NC
Chin strap for 20TG and 20RT headbands
ES42
Chin strap for 3000 and 5100 hard hats
Powered Air Purifying Respirator Components
Blower Assembly
PA1
Complete Blower Assembly with 10 hour battery
and Low Voltage Alarm
PA2
Complete Blower Assembly with 6 hour battery
Battery Chargers
PA1SMC
Quick Charger for PA1
PA1STC
Standard Charger for PA1
PA2SMC
Quick Charger for PA2
PA2STC
Standard Charger for PA2
20BT
Breathing tube only (for supplied air)
Breathing Tube Assemblies (for supplied air)
Include breathing tube, airflow control device, quickdisconnect nipple and belt. (Note: 20BT + F30 = V30)
Constant Flow Breathing Tube Assembly for use with
Breathing Air Compressors (Schrader and Snap-Tite also
available)
V30
With 1/4" Industrial Interchange steel (Hansen
compatible) quick-disconnect nipple
Constant Flow Breathing Tube Assemblies for use with
Bullard Free-Air Pumps
V35
With 1/2" Industrial Interchange, steel (Hansen
compatible) quick-disconnect nipple
Replacement Parts for Breathing Tube Assembly
S18051
Nylon breathing tube clamp
4612
Belt, Nylon webbing
Flow Control Device
Flow Control Valves
F30
Constant flow control valve with 1/4" Industrial
Interchange (Hansen compatible) quick-disconnect
nipple (other industrial fittings available)
F40
Adjustable flow control valve with 1/4" Industrial
Interchange (Hansen compatible) quick-disconnect
nipple (other industrial fittings available)
F35
Constant flow control valve with 1/2" Industrial
Interchange (Hansen compatible) quick-disconnect
nipple
Climate Control Assemblies
Replacement Parts and Accessories
PA1AF1
Air Flow Indicator
PA1FG3
Filter/Gasket Assembly (pack of 3)
PA1FGBP
Filter/Gasket Assembly (pack of 36)
PA1BT
Breathing Tube for Heads (26" standard length)
PA1BTXS
Breathing Tube for Heads (22" length)
PA1DB
Decon Belt/Comfort Pad
PA1DEB
Decon Extension Belt
For use with Breathing Air Compressors
Cold Tubes – Adjustable Flow (Schrader and Snap-Tite also
available)
AC1000
With 1/4" Industrial Interchange steel (Hansen
compatible) quick-disconnect nipple
Hot/Cold Tubes - Adjustable Flow (Schrader and Snap-Tite
also available)
HC2400
With 1/4" Industrial Interchange steel (Hansen
compatible) quick-disconnect nipple
WARNING
CATALOG
NUMBER
DESCRIPTION
DUAL-COOL™ - Climate Control Device
DC5040
With 1/4" Industrial Interchange steel (Hansen
compatible) quick-disconnect nipple. Includes
CH60 connector hose and nylon belt (Order vest
separately).
DC70M/L Medium/Large cooling vest
DC70XL/XXL X-Large/XX-Large cooling vest
Replacement Parts for Climate Control Assemblies
MV2400
Muffler/valve assembly for HC2400
CH60
Connector hose for use with DC5040
Climate Control Assembly for use with Bullard EDP30 or
ADP20 Free-Air Pump
Cool Tube - Adjustable Flow
Frigitron® With 1/2" Industrial Interchange steel
2000
(Hansen compatible) quick-disconnect nipple.
Air Supply Hoses and Fittings
V10 Series Starter Hose Kits for use with Breathing Air
Compressors (Schrader and Snap-Tite also available)
Include 25' (7.6 m), 3/8" I.D. rubber hose with 1/4" female
quick-disconnect coupler and V13 adapter fitting (3/8" hose-to3/8" pipe)
4696
With 1/4" Industrial Interchange steel (Hansen
compatible) quick-disconnect coupler
V10 Series Extension Hose Kits for use with Breathing Air
Compressors
Include 3/8" I.D. rubber hose, V11 hose-to-hose adapter fitting
and V13 hose-to-pipe fitting (3/8" hose-to-3/8" pipe)
5454
25' (7.6 m) Extension hose kit
5457
50' (15.2 m) Extension hose kit
5458
100' (30.5 m) Extension hose kit
V5 Series Coiled Hoses for use with Breathing Air
Compressors (Schrader and Snap-Tite also available)
Include 3/8" I.D. Nylon coiled hose with 1/4" female quickdisconnect coupler and 1/4" male quick-disconnect nipple
V52530
25' (7.6 m) with 1/4" Industrial Interchange steel
(Hansen compatible) fittings
V55030
50' (15.2 m) with 1/4" Industrial Interchange steel
(Hansen compatible) fittings
V20 Series Hoses for use with Bullard Free-Air Pumps
Include 1/2" I.D. rubber hose with 1/2" Industrial Interchange
(Hansen compatible) female quick-disconnect coupler and 1/2"
male quick-disconnect nipple
V2050ST
50' (15.2 m)
V20100ST 100' (30.5 m)
Distributed by
9 0 01
ed
Bullard GmbH
Hochkreuzallee 36
53175 Bonn-Bad Godesberg
Germany
Tel: +49 228 931933 0
Fax: +49 228 931933 50
ifi
Bullard
1898 Safety Way
Cynthiana, KY 41031-9303
Toll free: +877-BULLARD (285-5273)
Tel: +859-234-6616
Fax: +859-234-8987
www.bullard.com
IS O
CC20 respirators are not approved for use in any atmosphere immediately dangerous to life
or health (IDLH) or from which the wearer cannot escape without the use of a respirator.
Bullard products are manufactured and tested to exacting specifications. Any alteration or
modification of these products by the user may adversely affect product performance and
voids all product certifications. This data sheet is in summary form only for easy reference.
Refer to labels and instructions accompanying the product for more complete details
regarding use, maintenance, warnings and limitations.
Failure to use complete NIOSH-approved Bullard components and replacement parts voids
approval of entire assembly.
Ce
rt
ISO 9001
certified
©2002 Bullard. All rights reserved.
Bullard, Free-Air, and Sure-Lock are registered trademarks of Bullard.
It’s your life and you’re worth it is a trademark of Bullard.
Tychem is a registered trademark of the DuPont Company
4062 (0702)