VMware vCloud Director 1.0 Performance and Best Practices

VMware vCloud Director 1.0
Performance and Best
Practices
™
February 2011
PERFORMANCE STUDY
VMware vCloud Director 1.0 Performance and Best Practices
Table of Contents
Introduction ...................................................................................................................................................................................... 4
vCloud Director Architecture .................................................................................................................................................... 4
Terms Used in this Paper .............................................................................................................................................................5
Experimental Setup .......................................................................................................................................................................6
Server Sizing for the Oracle Database .............................................................................................................................6
Database Connection Tuning ...............................................................................................................................................6
Sizing for Number of Cell Instances ........................................................................................................................................7
LDAP Sync .........................................................................................................................................................................................8
LDAP Sync Latency for Different Numbers of Users .................................................................................................8
LDAP Sync Latency on a High Latency Network ........................................................................................................9
Performance Tips ......................................................................................................................................................................9
OVF File Upload .............................................................................................................................................................................10
OVF File Upload Latency for Different File Sizes ....................................................................................................... 11
Concurrent OVF File Upload Latency ............................................................................................................................. 12
File Upload in WAN Environment .................................................................................................................................... 13
Sizing and Performance Tuning Tips .............................................................................................................................. 15
Clone vApps across vCenter Server Instances ................................................................................................................. 16
Experimental Setup ............................................................................................................................................................... 16
Two Separated Datastores .................................................................................................................................................. 17
Datastore Shared Among ESX Hosts.............................................................................................................................. 17
Shared and Separated Datastores ................................................................................................................................... 18
Results ......................................................................................................................................................................................... 19
Performance Tuning Tips ..................................................................................................................................................... 19
Deploy vApp ..................................................................................................................................................................................20
Deploy Single vApp with Varying Number of VMs..................................................................................................20
Concurrently Deploy vApps with and without Fence Mode ............................................................................... 22
Performance Tuning Notes ................................................................................................................................................ 23
Inventory Sync............................................................................................................................................................................... 23
Sync Latency for Different Inventory Sizes ................................................................................................................. 23
In-Memory Inventory Cache .............................................................................................................................................. 24
Inventory Cache and JVM Heap Size Tuning .............................................................................................................. 25
Inventory Sync Resource Consumption ....................................................................................................................... 26
Load Balancing VC Listener ............................................................................................................................................... 27
Adjusting Thread Pool and Cache Limits ........................................................................................................................... 28
PERFORMANCE STUDY /2
VMware vCloud Director 1.0 Performance and Best Practices
Conclusion .......................................................................................................................................................................................30
References ......................................................................................................................................................................................30
About the Authors........................................................................................................................................................................ 31
Acknowledgements ..................................................................................................................................................................... 31
PERFORMANCE STUDY /3
VMware vCloud Director 1.0 Performance and Best Practices
Introduction
VMware vCloud™ Director gives enterprise organizations the ability to build secure private clouds that
dramatically increase datacenter efficiency and business agility. When coupled with VMware vSphere™, vCloud
Director delivers cloud computing for existing datacenters by pooling virtual infrastructure resources and
delivering them to users as catalogs.
This white paper addresses four areas regarding VMware® vCloud Director performance:
•
vCloud Director sizing guidelines and software requirements
•
Best practices in performance and tuning
•
Performance characterization for key vCloud Director operations
•
Behavior with low bandwidth and high latency networks
vCloud Director Architecture
Figure 1 shows the deployment architecture for vCloud Director. You can access vCloud Director from a Web
browser or through the VMware vCloud API. Multiple vCloud Director server instances (cells) can be deployed
with a shared database. In the current 1.0 release, only the Oracle database is supported. A vCloud Director server
instance can connect to one or multiple VMware vCenter™ Server instances.
VMware vCloud Director 1.0
VMware vSphere 4.0
ESX/ESXi Hosts
vCloud Director Cells
HTTPS
vCloud Director
Web Interface
vCenter Server
vCloud Director
Database
vCenter Database
Figure 1. VMware vCloud Director High Level Architecture
PERFORMANCE STUDY /4
VMware vCloud Director 1.0 Performance and Best Practices
Figure 2 shows the internal architecture of vCloud Director. Performance results for LDAP, Image Transfer (OVF
File Upload), and VC Listener are included in this paper.
Figure 2. vCloud Director Internal Architecture
Terms Used in this Paper
Definitions for key concepts in vCloud Director 1.0 follow. These terms have been used extensively in this white
paper. For more information, refer to the vCloud API Programming Guide [7].
•
vCloud Organization – A vCloud organization is a unit of administration for a collection of users, groups, and
computing resources. Users authenticate at the organization level, supplying credentials established by an
organization administrator when the user was created or imported.
•
vCloud Virtual Datacenters – A vCloud virtual datacenter (vDC) is an allocation mechanism for resources
such as networks, storage, CPU, and memory. In a vDC, computing resources are fully virtualized, and can be
allocated based on demand, service level requirements, or a combination of the two.
There are two kinds of vDCs:
– Provider vDCs – These vDCs contain all the resources available from the vCloud service provider. Provider
vDCs are created and managed by vCloud system administrators.
– Organization vDCs – These vDCs provide an environment where virtual systems can be stored, deployed,
and operated. They also provide storage for virtual media, such as floppy disks and CD-ROMs.
PERFORMANCE STUDY /5
VMware vCloud Director 1.0 Performance and Best Practices
An organization administrator specifies how resources from a provider vDC are distributed to the vDCs in an
organization.
•
vCloud Catalogs – Catalogs contain references to virtual systems and media images. A catalog can be shared
to make it visible to other members of an organization, and can be published to make it visible to other
organizations. A vCloud system administrator specifies which organizations can publish catalogs, and an
organization administrator controls access to catalogs by organization members.
•
vCloud Cells – vCloud cells are instances of the vCloud Director server. A vCloud cell is made up of several
components, including VC Listener, Console Proxy, Presentation Layer, and others as shown in Figure 2.
•
vApp – A vApp is an encapsulation of one or more virtual machines, including their inter-dependencies and
resource allocations. This allows for single-step power operations, cloning, deployment, and monitoring of
tiered applications, which span multiple VMs.
Experimental Setup
Table 1 shows the virtual machines that we configured in our test bed. All VMs ran on Dell PowerEdge R610
machines with 8 Intel Xeon CPUs @2.40GHz and 16GB RAM.
Table 1. Virtual Machine Configuration
OPERATING SYSTEM
Cell
RAM
4 vCPUs
8GB
64-bit Red Hat Enterprise Linux 5
Cell Database
vCenter Server
NUMBER OF
VCPUS
64-bit Windows Server 2003
vCenter Database
This section describes performance tuning and sizing recommendations for the Oracle database.
Server Sizing for the Oracle Database
An Oracle database server configured with 16GB of memory, 100GB storage, and 4 CPUs should be adequate for
most vCloud Director clusters.
Database Connection Tuning
Because there is only one database instance for all cells, the number of database connections can become the
performance bottleneck. By default, each cell is configured to have 75 database connections, plus about 50 for
Oracle’s own use. Experiments in this paper used the default setting.
When vCloud Director operations become slower, increasing the database connection number per cell might
improve the performance. If you change the CONNECTIONS value, you also need to update some other Oracle
configuration parameters. Table 2 shows how to obtain values for other configuration parameters based on the
number of connections, where C represents the number of cells in your vCloud Director cluster.
PERFORMANCE STUDY /6
VMware vCloud Director 1.0 Performance and Best Practices
Table 2. Oracle Database Configuration Parameters
ORACLE CONFIGURATION PARAMETER
VALUE FOR C CELLS
CONNECTIONS
75 × C + 50
PROCESSES
= CONNECTIONS
SESSIONS
= PROCESSES × 1.1 + 5
TRANSACTIONS
= SESSIONS × 1.1
OPEN_CURSORS
= SESSIONS
A database administrator can set these values in Oracle.
For more information on best practices for the database, refer to the vCloud Director Installation and
Configuration Guide [10] .
Sizing for Number of Cell Instances
vCloud Director can be easily scaled up by adding more cells to the system. We tested with up to 12 cell instances
with 10 fully loaded vCenter Server instances.
For this experiment, the Oracle database instance ran in a host with 12 cores and 16GB RAM. Each cell ran in a
virtual machine with 2 vCPUs and 4GB RAM.
In general, we recommend:
number of cell instances = n + 1 where n is the number of vCenter Server instances
This formula takes into account the considerations for VC Listener (which helps keep the vCenter Server
inventory up-to-date in the vCloud Director database), cell failover, and cell maintenance. In “Inventory Sync” on
page 23, we recommend a one-to-one mapping between VC Listener and the vCloud cell. This ensures the
resource consumption for VC Listener is load balanced between cells. We also recommend having a spare cell for
cell failover. This keeps the load of VC Listener balanced when one vCloud Director cell fails or is powered down
for routine maintenance.
We assume here that the vCenter Server instances are managing a total of more than 2000 VMs. If the vCenter
Server instances are lightly loaded, multiple instances can be managed by a single vCloud Director cell. For cases
where vCenter Server is lightly loaded, use the following sizing formula:
number of cell instances = n ÷ 3000 + 1 where n is the number of expected powered on VMs
For more information on the configuration limits in vCenter Server 4.0 and 4.1, refer to VMware vCenter Server
4.0 Configuration Limits [4], VMware vCenter Server 4.1 Configuration Limits [5], and VMware vCenter Server 4.1
Performance and Best Practice [6].
PERFORMANCE STUDY /7
VMware vCloud Director 1.0 Performance and Best Practices
LDAP Sync
vCloud Director supports importing users and groups from external LDAP servers. An external LDAP server is
one that is not part of the cloud that vCloud Director manages. When a LDAP user logs in, the vCloud Director
server checks if the necessary information for this user has been loaded. If the user is not loaded, vCloud Director
issues a LDAP search request to fetch the user information. In addition to checking and fetching user information,
the sync process also includes the removal of records for users who have been deleted in an external LDAP
server.
LDAP Sync Latency for Different Numbers of Users
LDAP sync in vCloud Director is implemented with a single thread. All LDAP users are updated in a sequential
manner. This approach ensures the resource consumption is small when a LDAP sync task runs a background job
within the vCloud Director server.
In our tests, we observed that, as the number of users increases, latency increases. Figure 3 gives you an idea of
what amount of LDAP sync latency to expect for the number of LDAP users on your system.
160
Latency in Seconds
140
120
100
80
60
40
20
0
0
2000
4000
6000
8000
10000
12000
Number of Users
Figure 3. LDAP Sync Latency in Seconds for 1000, 3000, and 10,000 LDAP Users
PERFORMANCE STUDY /8
VMware vCloud Director 1.0 Performance and Best Practices
LDAP Sync Latency on a High Latency Network
This test determines how much of a delay to expect for an LDAP sync operation when the external LDAP server’s
Active Directory contains a large number of users (10,000).
When the vCloud Director server is connected to the external LDAP server through a high latency network (for
example, DSL, Satellite, or T1), the sync latency increases linearly as shown in Figure 4.
This experiment did not limit the network bandwidth. If the available network bandwidth were also limited, the
LDAP sync latency might further increase.
60
Latency in Minutes
50
40
30
20
10
0
0
50
100
150
200
250
RTT in Milliseconds
Figure 4. LDAP Sync Latency for Round-Trip Time (RTT) with 10,000 LDAP Users = 1ms, 100ms, and 200ms
Performance Tips
To speed up the time it takes for vCloud Director to initially import LDAP users from an external LDAP server, we
recommend importing the groups first instead of importing individual users. When a group is imported, all users
in that group will be able to log into the vCloud Director server. The vCloud Director server automatically imports
the user information during the login process.
We also recommend that you infrequently run LDAP sync on the external LDAP server. When a LDAP user is
initially imported, for any subsequent login, vCloud Director syncs up this user with the external LDAP server. The
LDAP user information in the vCloud Director server database is always up to date, except if a user is deleted in
the LDAP server. A LDAP sync operation will disable the user as "out of sync" from the vCloud Director database
when a user is removed remotely.
PERFORMANCE STUDY /9
VMware vCloud Director 1.0 Performance and Best Practices
OVF File Upload
The Open Virtualization Format (OVF) is an open, portable, efficient, and extensible format for packaging and
distributing virtual systems. OVF was developed by the Distributed Management Task Force (DMTF), a
not‐for‐profit association of industry members dedicated to promoting enterprise and systems management and
interoperability. The vCloud API supports Version 1 of the OVF standard. For more information, refer to Open
Virtualization Format Specification [1] and Open Virtualization Format White Paper [2].
Because it is a widely-accepted standard format, OVF provides considerable flexibility in accommodating the
needs of a diverse collection of virtualization technologies. While this flexibility entails more complexity than a
vendor‐specific format might require, it also provides many advantages.
•
Virtual machines and appliances are distributed as OVF packages by many vendors.
•
Many vendors, including VMware, offer tools that simplify creating and customizing OVF virtual machines,
support converting virtual machines on existing virtualization platforms to OVF, or both.
•
OVF has the power to express the complex relationships between virtual appliances in enterprise
applications. Most of the complexity can be handled by the author of the appliance rather than the user
deploying it.
•
OVF is extensible, allowing new policies and requirements to be inserted by independent software vendors
and implemented by the virtualization platforms that support them without requiring changes to other
clients, other platforms, or the vCloud API itself.
Applications can be deployed in the vCloud infrastructure using vApps, which are made available for download
and distribution as OVF packages. A vApp contains one or more VM elements, which represent individual virtual
machines. vApps also include information that defines operational details for the vApp and the virtual machines it
contains. After an OVF package is uploaded to a vDC, a vApp template is created. A vApp template specifies a
set of files (such as virtual disks) that the vApp requires and a set of abstract resources (such as CPU, memory,
and network connections) that must be allocated to the vApp by the vDC in which the template is deployed.
Instantiation creates a vApp from the files specified in the template, and allocates vDC‐specific bindings for
networks and other resources. Figure 5 shows the state transitions from an OVF package to a vApp template and
a vApp to be deployed. For more information, refer to vCloud API Programming Guide [7].
descriptor.ovf
disk0.vmdk
vApp
vApp Template
OVF Package
upload
<VApp
Template...status=”8”
href=”http://.../vapp
Template-3”>
...
...
</VApp Template>
instantiate
<VApp...status=”8”
deployed=“false”
href=”http://.../vapp9”>
...
<Link rel=”deploy”...>
...
</VApp>
Figure 5. vApp State Transitions
As shown in Figure 6, an OVF file resides in a client machine. Before it can be uploaded into the cloud, the OVF
file needs to be transferred to the vCloud Director cell. This transfer could very likely happen in a WAN
environment where the bandwidth and speed of the network are limited. The performance also changes when
there are concurrent file transfers within one cell. The following sections describe all of these aspects in more
detail.
PERFORMANCE STUDY /10
VMware vCloud Director 1.0 Performance and Best Practices
VMware vSphere 4.0
VMware vCloud Director 1.0
ESX/ESXi Hosts
vCloud Director Cells
OVF
Package
HTTPS
vCenter Server
Client
Shared OVF
transfer disk buffer
vCenter Database
Figure 6. VMware vCloud Director High Level Architecture
Note: All the results for OVF file upload in this white paper were collected through the vCloud Director user
interface.
OVF File Upload Latency for Different File Sizes
Before it can upload an OVF package, the client needs to verify the checksum of the VMDK files. After this occurs,
the files in the OVF package are transferred to the vCloud Director cell. Upon the completion of file transfers from
the client to the cell, the cell verifies the checksum of VMDK files again to ensure that no files were corrupted
during this transfer. The last step is to upload the OVF package into one of the ESX hosts by using
deployOVFPackage API calls against vCenter Server.
The majority of time is spent in client-to-cell transfer, as shown in Figure 7. For bigger files, the total latency to
upload is longer.
PERFORMANCE STUDY /11
VMware vCloud Director 1.0 Performance and Best Practices
1200
Latency in Seconds
1000
800
cell2vSphere
600
cell prepare
client2cell
400
client checksum
200
0
947MB
2036MB
6383MB
File Size
Figure 7. OVF File Upload Latency Breakdown for Different File Sizes
Concurrent OVF File Upload Latency
In a production environment, a single cell handles multiple, concurrent OVF file transfers at the same time. The
performance characterization of the OVF file upload changes when the disk I/O pattern goes from sequential I/O
to random I/O. This is shown in Figure 8. Comparing the first bar with the second bar, to upload two OVF files
concurrently, each file transfer latency is almost doubled. The effectiveness of random disk I/O between two
concurrent file transfers and three concurrent file transfers is much less significant as shown in the second bar
and the third bar of Figure 8.
For this experiment, the vCloud Director server ran in a 64-bit Red Hat Linux 5 virtual machine with 4 vCPUs and
8GB RAM. The OVF file transfer location was on the same disk as the cell log files. A local disk of an ESX host
served as the datastore to back up the cell VM.
PERFORMANCE STUDY /12
VMware vCloud Director 1.0 Performance and Best Practices
800
700
Latency in Seconds
600
500
cell2vSphere
400
cell prepare
client2cell
300
client checksum
200
100
0
1 transfer
2 concurrent
transfers
3 concurrent
transfers
Figure 8. OVF Uploads with 1, 2, and 3 OVF Packages Transferring at the Same Time
File Upload in WAN Environment
Because OVF package upload often occurs in a WAN (Wide Area Network), it is important to show latency
trends with various network bandwidths and speeds. Table 3 shows the bandwidth, latency, and error rate for
three typical networks in a WAN.
Table 3. Typical Networks in a WAN
NETWORK
BANDWIDTH
LATENCY
ERROR RATE
DSL
512Kbps
100ms
0.05%
Satellite
1.5Mbps
500ms
0.10%
T1
1.5Mbps
100ms
0.05%
A WAN simulator, WANem, was used for this experiment. The layout is shown in Figure 9. WANem (Wan Area
Network EMulation) is a piece of software running on Knoppix, a well-known Linux distribution based on Debian.
For more information, refer to the WANem Simulator Web site [3].
PERFORMANCE STUDY /13
VMware vCloud Director 1.0 Performance and Best Practices
VMware vSphere 4.0
VMware vCloud Director 1.0
WANem Simulator
ESX/ESXi Hosts
vCloud Director Cells
vCloud Director
Web Interface
vCenter Server
vCloud Director
Database
vCenter Database
Figure 9. OVF File Upload with WANem Simulator
Compared with DSL, T1 bandwidth is much larger. The total time to upload the same 295MB size VMDK file for T1
is twice as fast as the one on DSL, as shown in Figure 10.
250
Minutes
200
150
100
50
0
T1
DSL
Satellite
Figure 10. OVF File Upload Trend for T1, DSL, and Satellite Network
Although the bandwidth of a satellite network is 1.5Mbps, which is twice as big as DSL network bandwidth, the
underlying link cannot fully utilize the bandwidth due to the TCP maximum receive window size of 64KB. The
TCP receive window size determines the amount of received data that can be buffered on the receive side before
the sender requires an acknowledgement to continue sending. For a sender to use the entire bandwidth
available, the receiver must have a receive window size equal to the product of the bandwidth and the roundtrip
delay.
PERFORMANCE STUDY /14
VMware vCloud Director 1.0 Performance and Best Practices
Here are some examples that show how the TCP receive window size affects bandwidth utilization:
•
For a DSL network:
the bandwidth delay product = bandwidth × roundtrip delay = 512Kbps × (100ms × 2 ÷ 1000)s = 12.8KB
Here, we take the DSL bandwidth from the previous table, 512Kbps. To get the roundtrip delay, we multiply
the DSL latency from the previous table (100ms) by 2 because we need to measure the latency to and from
the destination. Then we divide the product by 1000 to convert milliseconds to seconds.
This is well within the TCP maximum receive window size of 64KB.
•
For a satellite network:
the bandwidth delay product = 1.5Mbps × (500ms × 2 ÷ 1000)s = 1.5Mb = 192KB
This is bigger than the TCP maximum receive window size of 64KB, so 1.5Mbps is not fully utilized.
Sizing and Performance Tuning Tips
For OVF file upload, the vCloud Director server temporarily stores the OVF packages before they are transferred
to ESX hosts. The required disk space for the temporary buffer is determined by two elements. One is the
maximum number of concurrent OVF package uploads; the other is the file size for each OVF package. For
example, if at the peak, 20 concurrent transfers are expected, and each OVF package contains about 10GB VMDK
files, the required space is 20 × 10GB = 200GB. In a WAN environment, because an OVF transfer might take
longer to finish, the disk requirement for OVF upload can be larger because there may be more OVF packages
that are in the transfer state.
The same disk space could also be used for cloning vApps across vCenter Server instances. In that case, the disk
requirement should also include how many concurrent vApp clone operations could occur and how big each
vApp is. The next section describes how to achieve the best performance for cloning vApps across vCenter
Server instances.
If a file upload fails in the middle of a transfer between the client and the cell, the temporary files are kept in the
cell for some time. As a consideration for that, we recommend adding 20% disk space. The following is a sizing
formula:
disk size = max number of concurrent transfers × average file size × 1.2
Here, max number of concurrent transfers includes both OVF file transfers and other file transfers caused by
operations such as those initiated by cloning vApps across vCenter Server instances.
Because this disk buffer is very I/O intensive, we recommend separating it from the logging disk of the vCloud
Director server. This can be done by NFS mounting. This way, the disk operations can be separated from the cell
logging and OVF file uploads.
PERFORMANCE STUDY /15
VMware vCloud Director 1.0 Performance and Best Practices
Clone vApps across vCenter Server Instances
In vCloud Director 1.0, a VM clone operation is triggered when a vApp is instantiated from a vApp template.
When the underlying organization vDC does not have access to the source datastore on which the vApp
template resides, the same mechanism used to upload an OVF package is used to create the vApp. A unique
feature is implemented in the vCloud Director 1.0 release to improve the latency. This feature works when the
underlying organization vDC has access to the source datastore of the vApp template. The following section
provides more details on this topic.
Experimental Setup
The test bed consisted of two vCenter Server 4.1 instances. Each vCenter Server instance had two ESX 4.1 hosts in
a cluster.
VMware vCloud Director 1.0
VMware vSphere 4.0
2 Classic ESX
4.1 Hosts
vCloud Director Cell
HTTPS
vCenter Server 1
and its Database
vCenter Server 2
and its Database
vCloud Director
Web Interface
vCloud Director
Database
2 Classic ESX
4.1 Hosts
Figure 11. Testbed Setup for Inter-vCenter Clone Experiments
Two provider vDCs were created based on the two clusters from these two vCenter Server instances.
Corresponding organization vDCs were derived from the two provider vDCs. These two organization vDCs were
presented in the same organization. We then studied three datastore configurations to show the latency of the
cloning operation. Our tests show that datastore accessibility plays a very important role in terms of latency.
PERFORMANCE STUDY /16
VMware vCloud Director 1.0 Performance and Best Practices
Two Separated Datastores
Figure 12 shows two separated datastores.
Organization with two Org vDCs
Org vDC 1
2 Classic ESX
4.1 Hosts
Datastore 1
Org vDC 2
2 Classic ESX
4.1 Hosts
Datastore 2
Figure 12. Two Separated Datastores
In this design, the source vApp template resides on Datastore 1 in Org vDC1. A template was cloned to Datastore
2, which was accessed by one of the two ESX hosts managed by Org vDC 2.
Because ESX hosts in Org vDC 2 did not have access to Datastore 1, the vApp template was uploaded to the cell
first, and then a deployment OVF package API call was issued to the vCenter Server that was mapped to Org
vDC 2.
Datastore Shared Among ESX Hosts
If ESX hosts in Org vDC 2 have access to the same datastore as shown in Figure 13, the process to upload the
vApp template OVF package and then deploy it to vCenter Server can be replaced by single file copy API calls to
vCenter Server. This design improves performance dramatically. We discuss this in “OVF File Upload” on page 10
with more details.
PERFORMANCE STUDY /17
VMware vCloud Director 1.0 Performance and Best Practices
Organization with Two Org vDCs
Org vDC 1
Org vDC 2
2 Classic ESX
4.1 Hosts
2 Classic ESX
4.1 Hosts
Datastore shared
among ESX hosts
Figure 13. Datastore Shared Among ESX Hosts
Shared and Separated Datastores
Even if the destination datastore is not the same as the source datastore (as seen in Figure 14), the process to
clone VMs can still be optimized. In this case, VM files are copied directly between datastores and the
requirement to have the cell as the middle tier for buffering the OVF package is eliminated.
Organization with Two Org vDCs
Org vDC 1
Org vDC 2
2 Classic ESX
4.1 Hosts
2 Classic ESX
4.1 Hosts
Datastore 1
Datastore 2
Figure 14. Shared and Separated Datastores
PERFORMANCE STUDY /18
VMware vCloud Director 1.0 Performance and Best Practices
Results
Copying OVF packages directly between two datastores or within the same datastore is much faster than the
approach of uploading OVF packages. Figure 15 shows the latency trends for the three configurations.
The last bar is for Figure 12, where the destination organization vDC does not have access to the source datastore
on which the source vApp template resides. At almost eight minutes (488 seconds), this setup has the highest
latency. In contrast, the first and second bars (for the configurations shown in figures 13 and 14) show a large
improvement at close to 1 minute.
VM clones can be completed eight times faster when the datastore setup is correctly designed.
600
Latency in Seconds
500
400
300
200
100
0
same datastore shared
between org vDC
source datastore shared destination org vDC has no
but destination data store
access to source data
is different
store
Figure 15. VM Clone Latency for Different Datastore Setups
For the first two bars in Figure 15, the latency numbers are almost the same as the ones achieved directly through
vSphere. This shows that the additional time required by vCloud Director is negligible for VM clone operations
when compared with the time taken to clone VMs in vSphere.
Performance Tuning Tips
To achieve better performance for VM clones in vCloud Director 1.0, we recommend having a central datastore to
hold the most popular vApp templates and media files and have this datastore mounted to at least one ESX host
per cluster. This way, the destination organization vDC has access to both the source and destination datastores.
This removes the need to copy the OVF package files twice as discussed in “OVF File Upload” on page 10.
PERFORMANCE STUDY /19
VMware vCloud Director 1.0 Performance and Best Practices
Deploy vApp
In vCloud Director 1.0, vApps can be deployed with fence mode or without fence mode.
When a vApp is deployed in fence mode, the connections between the vApp and the organization network
traverse a vShield™ Edge virtual appliance, which provides protection for the vApp network and also extends the
organization network so that identical virtual machines can be run in different vApps. By extending the
organization network in this way, it is possible to run multiple, identical vApps without conflict—the vShield Edge
appliance is deployed on a per-vApp network basis, isolating the overlapping Ethernet MAC and IP addresses.
Figure 16 illustrates the difference between a vApp that is deployed with and without fence mode.
Figure 16. vApps Deployed with and without Fence Mode
In this section, we compare the performance of deploying vApps with and without fence mode.
Deploy Single vApp with Varying Number of VMs
First, we compare the performance when a single vApp with a varying number of VMs is deployed and powered
on.
140
Time in seconds
120
100
80
deploy with fence
60
deploy without fence
40
20
0
1VM
3VM
5VM
Number of VMs
10VM
Figure 17. Deploy a Single vApp with and without Fence Mode
PERFORMANCE STUDY /20
VMware vCloud Director 1.0 Performance and Best Practices
As shown in Figure 17, when compared with deploying a vApp without fence mode, deploying a vApp with fence
mode takes a longer time. This is because vCloud Director needs to perform extra configuration in order to
deploy a vApp with fence mode. More detail is shown in Figure 18. Before powering on the vApp, vCloud Director
needs to deploy and configure a vShield Edge VM as the gateway, which takes more than 80 seconds.
Breakdown of Deploy Fence Time ( in Seconds)
If the vApp is deployed without fence mode, only the last two steps (reconfigure VMs and power them on) are
required.
160
140
120
Power on VM
100
Reconfigure VM
Before reconfigure VM
80
Power on vse
Reconfigure vse
60
Rename vse
Deploy vse OVF template
40
Create folder
20
Add dvPort groups
0
1 VM
3 VMs
5 VMs
10 VMs
Number of VMs in vApp
Figure 18. Deploy a Single vApp with Fence Mode: Operation Breakdown
Figure 18 also shows that deploying vApps with an increasing number of VMs increases the deployment time
increases only slightly. This is because only one vShield Edge instance is required, even with multiple VMs in a
vApp.
PERFORMANCE STUDY /21
VMware vCloud Director 1.0 Performance and Best Practices
Concurrently Deploy vApps with and without Fence Mode
In this section, we compare the performance when we concurrently deploy and power on vApps with and
without fence mode.
4
3.5
3
Ops/Minute
2.5
2
1.5
1
0.5
0
0
2
4
6
8
10
12
Number of Concurrent vApp Deployments
Figure 19. Concurrently Deploy vApps with Fence Mode
For fence mode, because each operation takes a longer time, the throughput is not very large when the
concurrency level remains low. However, the throughput keeps increasing when the concurrency level increases.
This means that when vApp deployments are performed concurrently, there is no significant performance
degradation.
50
45
40
Ops/minute
35
30
25
20
15
10
5
0
0
2
4
6
8
10
12
Number of Concurrent vApp Deployments
Figure 20. Concurrently Deploy vApps without Fence Mode
PERFORMANCE STUDY /22
VMware vCloud Director 1.0 Performance and Best Practices
For deploying without fence mode, the throughput is higher than with fence mode because less configuration
needs to occur. Here, too, throughput keeps increasing when the concurrency level increases.
Performance Tuning Notes
The latency to deploy a vApp in fence mode does not increase much when there are more VMs in the vApp. This
is because fence mode adds a fixed cost to the deployment time (deploy and configure a vShield Edge VM one
time) and the increase in time is not proportional to the number of VMs in the vApp.
Deploying multiple vApps concurrently can achieve high throughput.
Inventory Sync
When a vCloud Director cell is initialized, the current vCenter Server inventory information is retrieved and the
relevant data is stored in the empty vCloud Director database. This process is called initial sync. The vCloud
Director server may be shut down and restarted. When it is restarted, all the current vCenter Server inventory
information is retrieved again. Changes to the inventory data are stored in the vCloud Director Database. This
process is called restart-cell-sync. The difference between initial sync and restart-cell-sync is the state of the
vCloud Director database. Initial sync starts with an empty vCloud Director database, whereas restart-cell-sync
starts with a database that already contains the inventory information. After restart-cell-sync, the vCloud Director
database is periodically updated.
The vCenter Server process may also be shut down and restarted. When this occurs, the vCloud Director server
tries to reconnect to the vCenter Server and re-sync the inventory information. This process is called reconnectvCenter-sync. Reconnect-vCenter-sync takes less time than restart-cell-sync because, in reconnect-vCentersync, the vCloud Director server has a cache that stores the inventory information in memory.
Sync Latency for Different Inventory Sizes
Figure 21 shows that the latencies for initial sync and restart-cell-sync increase linearly as the number of virtual
machines in the system grow. For reconnect-vCenter-sync latency, the default inventory cache is not big enough
to hold 3000 inventory objects, so some inventory objects must be fetched from the vCloud Director database.
This process causes the significant latency increase seen between 2000 and 3000 inventory sizes.
For the restart-cell-sync experiment, there are no changes for the inventory objects, and so there are no
database inserts required. In contrast, the latency for initial sync is higher because inventory objects need to be
inserted into the vCloud Director database. The latency for initial sync can be longer than the latency for restartcell-sync even when the inventory size is relatively small. The majority of time is spent comparing the difference
between the stored inventory object in the vCloud Director database with the one in vCenter Server.
For reconnect-vCenter-sync, because the in-memory inventory cache can potentially hold all or most of the
inventory objects, no extra time is needed to fetch these objects from the vCloud Director database. This is why
reconnect-vCenter-sync gives the best performance among the three types of inventory syncs. The following
sections describe more about the inventory cache effects and how to tune the inventory cache for better
performance.
PERFORMANCE STUDY /23
VMware vCloud Director 1.0 Performance and Best Practices
initial sync
restart-cell-sync
reconnect-vCenter-sync
50
45
40
Seconds
35
30
25
20
15
10
5
0
1000
2000
3000
Number of Inventory Items
Figure 21. Inventory Sync Latencies
In-Memory Inventory Cache
An in-memory inventory cache is implemented in vCloud Director 1.0. The cache saves the time to fetch inventory
information from the database and the time to de-serialize the database record. Figure 22 demonstrates the
effectiveness of the inventory cache for reconnect-vCenter-sync usage. When the cache size is set to 10,000
1
inventory items, the cache-hit ratio is much higher. The latency to sync 5000 VMs is also much faster when the
cache-hit ratio is higher.
1
Cache-hit ratio is the percentage of accesses to the cache that result in hits.
PERFORMANCE STUDY /24
VMware vCloud Director 1.0 Performance and Best Practices
reconnect-vCenter-sync
60
50
Seconds
40
30
20
10
0
1000
5000
10000
Inventory Cache Sizes
Figure 22. Sync Time for Inventory Cache Sizes Set to 1000, 5000 and 10,000 with 5000 VMs
Inventory Cache and JVM Heap Size Tuning
vCloud Director maintains an inventory of all vCenter Server entities it manages. A part of this inventory is cached
by each vCloud Director cell. This caching process depends on the size of the cache configured for each cell.
There is one sizing configuration for inventory cache for all cells of the vCloud Director installation. Serialization
and deserialization of vCenter Server entities and querying the database for these objects are expensive. So, the
overall performance of vCloud Director is greatly enhanced by proper sizing. This section describes how this
sizing matters and how inventory cache prioritizes objects.
By default, each vCloud Director cell is configured for 5000 inventory items (total inventory cache entries
including hosts, networks, folders, resource pools, and so on). We estimate that this sizing is optimal for 2000
VMs. Our measurements show that on average, each inventory cache item is about 30KB in size. So, with the
2
default configuration, an installation supporting 2000 VMs may end up using 5000 × 30KB = ~150MB.
Note: For steps to change the inventory cache, see “Adjusting Thread Pool and Cache Limits” on page 28.
Because the number of supported VMs increases in the vCD when additional vCloud Director cells are added,
proper tuning of this inventory size will help boost performance. We recommend the following formula to help
figure out what number to use for the cache size on each cell:
Inventory Cache Size = 2.5 × (Total Number of VMs in vCloud Director)
We assume here that most VMs in one or more instances of vCenter Server that are managed by vCloud Director
are the ones created by vCloud Director. If that is not the case, substitute the Total number of VMs in vCloud
Director with Total number of VMs in each vCenter Server.
As the number of VMs managed by vCloud Director increases, you can either add new vCenter Server instances
to support more VMs, or you can utilize vCenter Server to its full scale (3000 VMs for vSphere 4.0 and 10,000
VMs for vSphere 4.1). Because the inventory in vCloud Director is the aggregate of all vCenter Server inventories
2
5000 × (30KB) = 5000 × (30 × 1024) bytes = 153,600,000 bytes ÷ 1,048,576 = 146MB
PERFORMANCE STUDY /25
VMware vCloud Director 1.0 Performance and Best Practices
managed by it, the above sizing formula still holds.
An additional detail that you should pay attention to is the JVM heap size for each vCloud Director cell process.
As mentioned previously, an increase in the total number of inventory items cached requires more memory on
each cell. So, it is essential to increase the JVM heap equivalently. By default, JVM heap size is configured to be
1GB for the process. This is good for supporting 5000 inventory cache entries. If the number of cached entries is
changed, for example, to 15,000 (an additional 10,000) for a large vCloud Director installation, you might need to
increase the JVM heap size to support additional cache entries. In this example, the JVM heap size should be
increased to 1.5GB (1GB original + 10,000 x 30KB = 300MB + 200MB as some buffer for other caches/objects with
an increase in total VMs) to support the additional 10,000 cache entries per vCloud Director cell.
For large installations, if the JVM heap size is not increased, it is likely that the vCloud Director cell will run out of
memory, resulting in poor performance and a possible cell failure. For more information, refer to knowledge base
article 1026355 to change vCloud Director JVM Heap size [9].
Inventory Sync Resource Consumption
During inventory sync, up to 25% out of 4 vCPUs can be consumed because inventory sync is implemented as a
single thread task. For the vCloud Director database, reconnect-vCenter-sync consumes the least CPU among all
three types of syncs because most objects are held in the inventory cache, and there is no need to query and
insert the backend database. For initial sync and restart-cell-sync, the Oracle database consumes less than 20%
of 4 vCPUs. As we have discussed, most of the CPU usage is consumed by database inserts in the initial sync
case. However, for restart-cell-sync, most of the CPU consumed is for database queries.
All three types of syncs depend on vCenter Server to provide the inventory information. As the number of
inventory objects gets bigger, the resource consumption in vCenter Server is more significant. Figure 23 shows
vCenter Server CPU usage for reconnect-vCenter-sync with a different number of VMs.
Percentage of 4 vCPU (400%) Used
120
100
80
60
3000 VMs
2000 VMs
40
1000 VMs
20
0
0
5
10
15
20
25
30
35
40
45
50
55
Sample Points Every 5 Seconds
Figure 23. vCenter CPU Usage for Reconnect-vCenter-Sync with 1000, 2000 and 3000 VMs
PERFORMANCE STUDY /26
VMware vCloud Director 1.0 Performance and Best Practices
Load Balancing VC Listener
vCloud Director has a service called VC Listener (Inventory Service) through which it monitors and aggregates
changes of vCenter Server entities. Each VC Listener service is capable of listening for changes from one or more
vCenter Server instances. However, there is only one VC Listener service that is listening to a given vCenter
Server. vCloud Director manages which cell will listen for changes to which vCenter Server. If any cell that was
listening to vCenter Server changes fails, vCloud Director automatically picks another live cell to continue
listening for changes.
By default, vCloud Director load balances evenly among available live cells when failure occurs. However, vCloud
Director does not have automatic load balancing when things are working fine and new cells are added to an
existing cluster or failed cells are brought online.
For example, consider a vCloud Director installation with two cells, A and B, and two vCenter Server instances
(vCenters), VC1 and VC2. By default, vCloud Director tries to assign each cell one vCenter to listen for changes.
Suppose cell A gets assigned to VC1 and cell B to VC2. When cell B fails, VC2 is failed over to cell A. Now if cell B
is brought back online, cell A continues to listen for both vCenters and vCloud Director does not rebalance the
load. This does not mean that all interactions with VC2 or VC1 have to go through cell B. Cell B will be equally
functional, but cell A will be more loaded in terms of CPU usage.
Figure 24. Detection vCenter Listener Location in vCloud Director User Interface
Very large installations of vCloud Director (greater than or equal to 10,000 VMs) are likely to have more than one
vCloud Director cell and one vCenter. Under this circumstance, it is essential to monitor how many vCenters are
managed by each cell and determine if there is any room on other cells. You can view the assignments of
vCenters to cells on the vCenters list page, as shown in Figure 24.
vCloud Director has functionality that allows you to manually load balance existing load. In the previous example,
by manually reconnecting any one vCenter (that is, VC1 or VC2) from the vCenters list page, vCenter Director will
reassign the vCenter to cell B since it had no assigned vCenter to which to listen.
vCloud Director considers all cells to be the same in terms of physical resources available.
PERFORMANCE STUDY /27
VMware vCloud Director 1.0 Performance and Best Practices
Note: Reconnecting a vCenter will incur some down time for actions performed against that particular vCenter,
so we recommend you reconnect the vCenter when overall vCloud Director activity is low. It usually takes
between 5-30 seconds to move the VC Listener from one cell to another because vCloud Director has to
disconnect from the current cell and connect back from a different cell. This process will not affect currently
running VMs in any way; they will continue to function without any interruption.
Adjusting Thread Pool and Cache Limits
A vCloud Director installation has preconfigured limits for concurrent running tasks, various cache sizes, and
other thread pools. These all are configured with good default values, which are tested to work within an
environment of 10,000 VMs. Some of these numbers are also configurable in case you want to adjust them. You
must restart the cell for the changes to go into effect.
Table 4. Thread Pool Limits
THREAD
POOL
DEFAULT
SIZE (FOR
EACH CELL)
USAGE/INFORMATION
HOW TO ADJUST
Tasks
128
Maximum number of concurrent tasks that can
be executed per cell of a vCloud Director
installation. This is a global task count and is not
scoped per user or organization. Different cells
of the same vCloud Director installation can
have different values.
org.quartz.threadPool.threadCount = N
Maximum number of concurrent threads that
can fetch VM thumbnail images from vCloud
Director Agent running on an ESX host. Only
thumbnail images for running (powered on)
VMs are collected. Thumbnails are also retrieved
in batches, so all VMs residing on the same
datastore or host will be retrieved in batches.
vCloud Director only fetches thumbnails if they
are requested and once fetched, also caches
them. Thumbnails are requested when a user
navigates to various list pages or the dashboard
that displays the VM image.
Not configurable.
VM
Thumbnails
32
Where N is some number of concurrent
tasks you want to run on a given cell.
PERFORMANCE STUDY /28
VMware vCloud Director 1.0 Performance and Best Practices
Table 5. Cache Limits in vCloud Director 1.0
CACHE
DEFAULT
SIZE (FOR
EACH CELL)
USAGE/INFORMATION
HOW TO ADJUST
VM Thumbnail
Cache
1000
Maximum number of VM thumbnails
that can be cached per cell.
cache.thumbnail.maxElementsInMemory = N
Each cached item has a time to live
(TTL) of 180 seconds.
cache.thumbnail.timeToIdleSeconds = X
Holds information about the security
context of logged in users.
cache.securitycontext.maxElementsInMemory =
N
Each item has a TTL of 3600 seconds
and idle time of 900 seconds.
cache.securitycontext.timeToLiveSeconds = T
Holds information about the user
sessions for logged-in users.
cache.usersessions.maxElementsInMemory = N
Security
Context Cache
User Session
Cache
Inventory
Cache
500
500
5000
cache.thumbnail.timeToLiveSeconds = T
cache.securitycontext.timeToIdleSeconds = X
cache.usersessions.timeToLiveSeconds = T
Each item has a TTL of 3600 seconds
and idle time of 900 seconds.
cache.usersessions.timeToIdleSeconds = X
Holds information about vCenter
Server entities managed by vCloud
Director.
inventory.cache.maxElementsInMemory = N
Each item has a LRU (least recently
used) policy of 120 seconds.
In order to adjust any of these configured values, perform the following steps:
1.
Stop the cell. This releases the lock that the cell has on the file you will edit.
2. Edit the global.properties file, which is usually found in <vcloud director install
directory>/etc/.
3. Add the desired configuration lines. For example, org.quartz.threadPool.threadCount = 256.
4. Save the file.
5. Start the cell.
vCenter Server configuration limits are very important because vCloud Director utilizes vCenter Server for many
operations. For vCenter Server 4.0 configuration limits, refer to VMware vCenter Server 4.0 Configuration Limits
[4]. For vCenter Server 4.1 configuration limits, refer to VMware vCenter Server 4.1 Configuration Limits [5].
PERFORMANCE STUDY /29
VMware vCloud Director 1.0 Performance and Best Practices
Conclusion
In this paper, we discuss some of the features of the vCloud Director 1.0 release, performance characterizations
including latency breakdown, latency trends, resource consumption, sizing guidelines and hardware
requirements, and performance tuning tips. The following are some of the vCloud Director best practices for
performance presented in the paper:
•
Ensure the inventory cache size is big enough to hold all inventory objects.
•
Ensure the JVM heap size is big enough to satisfy the memory requirement for the inventory cache and
memory burst so the vCloud Director server does not run out of memory.
•
Import LDAP users by groups instead of importing individual users one by one.
•
Ensure the system is not running LDAP sync too frequently. The vCloud database is updated at regular
intervals.
•
In order to help load balance disk I/O, separate the storage location for OVF uploads from the location of
vCloud Director server logs.
•
Have a central datastore to hold the most popular vApp templates and media files and have this datastore
mounted to at least one ESX host per cluster.
•
Be aware that the latency to deploy a vApp in fence mode has a static cost and does not increase
proportionately with the number of VMs in the vApp.
•
Deploy multiple vApps concurrently to achieve high throughput.
•
For load balancing purposes, it is possible to move a VC Listener to another vCloud Director instance by
reconnecting the vCenter Server through the vCloud Director user interface.
References
[1] Open Virtualization Format Specification
http://www.dmtf.org/standards/published_documents/DSP0243_1.0.0.pdf
[2] Open Virtualization Format White Paper
http://www.dmtf.org/standards/published_documents/DSP2017_1.0.0.pdf
[3] WANem Simulator Web site
http://wanem.sourceforge.net/
[4] VMware vCenter 4.0 Configuration Limits
http://www.vmware.com/pdf/vsphere4/r40/vsp_40_config_max.pdf
[5] VMware vCenter 4.1 Configuration Limits
http://www.vmware.com/pdf/vsphere4/r41/vsp_41_config_max.pdf
[6] VMware vCenter 4.1 Performance and Best Practice
http://www.vmware.com/files/pdf/techpaper/vsp_41_perf_VC_Best_Practices.pdf
[7] vCloud API Programming Guide
http://www.vmware.com/pdf/vcd_10_api_guide.pdf
[8] vCloud Director 1.0 Release Note
http://www.vmware.com/support/vcd/doc/rel_notes_vcloud_director_10.html
[9] Changing vCloud Director Java heap size to prevent java.lang.OutOfMemoryError messages
http://kb.vmware.com/kb/1026355
[10] vCloud Director Installation and Configuration Guide
http://www.vmware.com/pdf/vcd_10_install.pdf
PERFORMANCE STUDY /30
VMware vCloud Director 1.0 Performance and Best Practices
About the Authors
John Liang is a Staff Performance Engineer at VMware. Since 2007, John has been working as a technical lead
for performance projects on VMware products such as VMware vCloud Director, VMware vCenter Update
Manager, VMware vCenter Site Recovery Manager (SRM), VMware vCenter Converter, and VMware vCenter Lab
Manager. Prior to VMware, John was a Principal Software Engineer at Openwave Systems Inc., where he
specialized in large-scale directory development and performance improvements. John received a M.S. degree in
Computer Science from Stony Brook University.
Ritesh Tijoriwala is a Senior Member of Technical Staff at VMware. Ritesh is a lead engineer for the Performance
and Scalability for VMware vCloud Director and a key engineer for Interoperability with vCenter, Failover and
Inventory related functionality for VMware vCloud Director. Ritesh has received his M.S. in Computer Science
from California State University, Fresno.
Xuwen Yu is a Member of Technical Staff at VMware where he works on several projects including VMware
vCloud Director, VMware vCenter Update Manager and ESX host simulator. Xuwen received his Ph.D. in
Computer Science and Engineering from the University of Notre Dame in 2009.
Qiang Ma is a Member of Technical Staff at VMware where he mainly works on VMware vCloud Director and
VMware vCenter Lab Manager. Qiang received his M.S. degree in Computer Engineering (ECE) from Stony Brook
University.
Acknowledgements
We want to thank Rajit Kambo and Jennifer Anderson for their valuable guidance and advice. Their willingness to
motivate us contributed tremendously to this white paper. We would also like to thank Andrew Dong, Eddie
Dinel, Hang Cheng, Stephen Evanchik, Ravi Soundararajan, Reza Taheri, Borislav Deianov, Paul Herrera, Mahdi
Ben Hamida, Snorri Gylfason, Bhavesh Mehta, Dushyanth Nataraj, David Baldwin, Kaushik Banerjee, and Jason
Carolan. Without their help, this white paper would not have been possible. Finally, we would like to thank Julie
Brodeur for help editing and improving this white paper.
PERFORMANCE STUDY /31