Cross Technologies 1582-10M Specifications

Product Brochure
MT9083A
ACCESS Master™
850/1300 nm OTDR for MMF
780/1310/1383/1490/1550/1625/1650 nm OTDR for SMF
All-in-One Solution for Optical Fiber Construction and
Maintenance of Access, FTTx, LAN and Metro Networks
850/1300 nm OTDR for MMF
780/1310/1383/1490/1550/1625/1650 nm OTDR for SMF
MT9083A ACCESS MASTER OVERVIEW
Optical fibers are a key technology in today’s modern communications systems, including access networks such as FTTx,
CATV, and optical LANs. Moreover, optical-fiber technologies are playing increasingly important roles in mobile communications and digital broadcasting systems. Technicians maintaining these diverse systems are forced to carry a large variety
of test equipment on-site, including OTDRs, Light Sources, Optical Power Meters, Visible Light Sources, etc., as well as a
notebook computer for evaluating the FTTx QoS. On the other hand, fiber construction requires measuring instruments with
different functions and performance. As an example, FTTx access networks use single mode (SM) fiber whereas optical
LANs use multimode (MM) fiber. In addition, core and backbone networks utilize long fibers while optical access networks
use short fibers, both requiring different types of measuring instruments with different performance. But now Anritsu’s new
line of MT9083A ACCESS Master OTDRs solves all these problems by providing all the measurement functions and performance required for optical fiber construction and maintenance in a compact, lightweight, all-in-one unit that eliminates the
burden of carrying many different test sets and instruments on-site. Whatever your work, construction or maintenance, long
haul or intra-building, Anritsu has an MT9083A model for your needs.
Key Features
• Ready to test in less than 15 seconds…and all day without recharging
• Specialized testing modes simplify operation
• High resolution and high dynamic range ensure thorough and complete fiber evaluation
• Intelligent analysis software identifies problem splices, connectors and even macrobends
• Rugged, sealed design provides years of service in the most challenging environments
• IP testing option verifies throughput, frame loss and point-to-point connectivity
• Test up to four wavelengths with a single unit-single mode, multimode or both
• Unique in-service testing without the need for external filters
2
Designed with the Features that Matter Most
hen buying products, you tend to choose ones that are innovative and from established companies.When you need to
W
install and maintain optical networks, this should also apply. With over 50 years of combined OTDR design, Anritsu, which
now includes NetTest, delivers the features that matter.
Having been in the test and measurement business for a long time, we understand that things like performance, portability,
reliability, easy operation and of course price are important.
Quick Startup
No Experience Required
The MT9083A is ready for measurement just 15 seconds
after power-on so productive work can start immediately.
With the MT9083A, the experience is built in. With specialized testing modes, automatic parameter selection, PASS/
FAIL indicators as well as features to virtually eliminate the
chance to get “bad” results, the MT9083A can make anyone
seems like a 20 year veteran. It’s not called the ACCESS
Master for nothing!
Long Battery Life
Since AC power is not always available where you need it,
especially at fiber pedestals, the MT9083A typically provides
up to 8 hours of operation on a single charge. This coupled
with an optional car cord (for cigarette lighter operation)
guarantees the MT9083A is ready when you are.
Easy “drag and drop” File Transfers
When the MT9083A is connected to a PC via a USB cable,
the internal memory of the ACCESS Master can be directly
accessed. Data can be selected, dragged and dropped
into the PC memory, greatly simplifying file transfers.The
MT9083A also supports use of USB memory sticks.
Portable
With its light weight design and user friendly dimensions,
the MT9083A is perfect for the outside plant environment
and can easily be managed with one hand. The shoulder
strap (part of the protector option) further increases portability when travelling from the truck to the testing site.
Common OTDR Data Format
The MT9083A supports the universal Telcordia SR-4731
(issue 2) format making it compatible with not only legacy
Anritsu and NetTest products, but with many other vendors
data.
Rugged
The MT9083A features a solid casework with no fans or
vents to keep dust or moisture from entering the unit.In
addition, the protector option (MT9083A-010) includes rubber bumpers and a display cover for additional protection
from those minor mishaps.
Free and Simple Software Upgrades
Firmware upgrades are easily performed via USB and available from the Anritsu website for registered users or through
Anritsu customer support.
Generous Data Storage
With the ability to store up to 1,000 traces in internal memory and up to 30,000 via a USB device, the MT9083A offers
plenty of storage for collecting and managing data.
3
Compact, Light Weight and All-in-one
With its versatile built-in functions, the MT9083A offers the ideal solution for efficient optical fiber construction and maintenance.
All-in-one Test Set
The MT9083A delivers full featured OTDR performance plus loss test set and quality of service measurement in a surprisingly small and lightweight package. At only 28.4 cm wide x20 cm tall x7.7 cm deep and 2.2 kg (4.8 lbs.), it is field portable,
yet rugged enough to withstand the outside plant environment.When equipped with power meter, visual light source and IP
test options, it replaces several, larger pieces of test equipment.
Up to 8 hour battery life plus quick recharge
Numeric keypad with dedicated keys for easy operation
Optical Power meter options with up to +30 dBm measurement range
Dedicated function keys for selecting parameters
Rotary dial for precision cursor movement
Visible laser source for easy fiber identification and
bend/break location
Up to four wavelengths from a single port for any application
Dual USB ports for quick and easy data transfer
Arrow keys for quick zooming and navigation through
menus
START key for simple one-button testing
6.5 inch color, TFT-LCD display with simple menus
There are two types—a Standard type for indoor use,
and an Enhanced type for use both indoors and outdoors
IP options for verifying QoS of 10/100/1000 MB links
4
Exceptional OTDR Performance…
from the World’s First OTDR Manufacturer
Evaluation of access networks ranging from a few kilometers to metro networks reaching up to 100 km in length is
becoming commonplace, requiring OTDRs to have the performance and functions for evaluating both short and long fibers. Designed with this in mind, the ACCESS Master delivers on both fronts.
Improved Short Fiber Analysis
Extended Range Testing of 100+ km Fibers
An event dead zone of less than 1m (80 cm typical) and a
sampling resolution of 5 centimeters allow the MT9083A to
evaluate connections and troubleshoot central office, FTTx
and intra-building faults with ease – providing a level of
detail never before seen.
In addition to its superb high-resolution performance, the
MT9083A also features up to 38.5dB of dynamic range
allowing it to easily test 100+ km spans making it a very
useful tool for any network type.
Fig 2: S
pans of over 100 km are also easily tested making the MT9083A the
only tool you will need - for any network type.
Fig. 1: W
ith its high resolution optics, the MT9083A provides exceptional
detail allowing users to quickly determine where the problem is-even
when events are closely spaced.
Convenient Features
Active fiber check
indoors, and the Enhanced type (MT9083A1), offering easy
viewing for working both indoors and outdoors
Not only can OTDR measurements be effected when the
optical fiber is in-service but there is a potential risk of
damage to the transmitter and OTDR receiver. To prevent
these problems, the MT9083A verifies if light is present
before starting measurement and will not transmit if it is. An
on-screen warning and internal OTDR protection are also
part of this useful feature.
Event Table with User Defined Thresholds
PASS/FAIL thresholds for key acceptance criteria such as
splice loss, connector loss and reflectance can be set in
the MT9083A allowing technicians to easily assess a fiber’s
condition. Failing values are clearly highlighted in the event
table alerting technicians of potential problems.
Waveform Comparison Function
Multiple Wavelengths and Models
Compare current and stored trace data to easily assess
changes over time and to locate problems before they effect
service or compare traces at different wavelengths to identify installation issues such as macrobending.
With nine available wavelengths spanning both single mode
and multimode, the ACCESS Master MT9083A is sure to
meet your individual needs. Up to four of these wavelengths can be combined into a single optical output providing full spectrum characterization.
Integrated Macrobend Detection
Wavelengths for Today’s Networks
With many technicians making the switch from copper
installations to optical fiber, installation issues such as macrobends are bound to occur. To help prevent this, Anritsu
has developed a macrobend detection feature for the
MT9083A that will alert technicians when a possible macrobend is present. This provides a higher quality of service
for the customer and eliminates costly troubleshooting for
you.
Sometimes you just need more than the traditional 1310
and 1550 nm wavelengths to certify your next generation networks. The MT9083A offers a host of specialized
wavelengths including1383 nm for water peak verification
of CWDM carrying fibers, 1650 nm (with integrated filter) for
live fiber troubleshooting, 1490 nm for verification of voice,
data and IP based video services and 780 nm for in-service
troubleshooting of FTTx networks - without the need for any
additional filters.
Supports Two Display Types
There are two types of 6.5-inch, TFT, color LCD—the
Standard type (MT9083A), offering easy viewing for working
5
Solutions for Various Measurement Needs
Products that offer many features are often complicated to use. The MT9083A however, simplifies operation by offering
task-specific testing modes that automate testing and guide novice users. Dedicated testing modes are available for fault
location, cable installation, loss budget testing, visual fault location and IP testing.
NETWORKS PC Software for Analysis and
Reporting
Simple Operation
To simplify testing, the MT9083A features dedicated measurement modes via the top menu to automate and simplify
the task at hand.
Once the data is collected, NetWorks PC emulation software makes analysis and report generation a breeze.
Professional reports including splice loss, fiber acceptance
and exceptions as well as various printing options are possible with only a few mouse clicks.
Fig.3: Dedicated measurement modes simplify testing for any skill level.
Fault Location
Fig.4: Comprehensive, professional reports are easily generated
FAULT LOCATE mode is designed for the novice or someone who only uses an OTDR occasionally. Simply connect
the fiber and press START. The unit will verify the fiber is
connected correctly, select testing parameters and provide
a text response indicating fault/break location - easy to read
results for any skill level.
General OTDR Testing
For those who have more experience or would like to perform more advanced testing, STANDARD OTDR mode
allows the user to set all parameters and compare traces
manually, automatically or somewhere in between.
Optical Fiber Construction and Certification
When final cable acceptance is the task at hand,
CONSTRUCTION mode greatly simplifies operation through
its innovative wizard. Select the required testing wavelengths, number of fibers and file naming scheme and
construction mode acts as the project manager guiding the
user through the testing, while ensuring consistency with
testing parameters and filenames - virtually eliminating user
induced errors and missing files.
Value
Whatever your construction or maintenance needs, the new
ACCESS Master MT9083A is designed to reduce the time
to install, commission and maintain your optical networks –
without breaking your budget.
Fig.5: Various printing options ensure you have the results you need
6
A True all-in-one Tester
An OTDR, Optical Power Meter, Visible Light Source, and IP tester are built into Anritsu’s compact, light-weight MT9083A
supporting tasks ranging from searching for faults in optical fibers to QoS evaluation to FTTx troubleshooting with just one
unit.
Complete Loss Test Set Features
Standard Stabilized Light Source
Optical Power Meter Options - up to +30 dBm
The OTDR port also functions as a stabilized light source
providing continuous wave, 270Hz, 1kHz and 2kHz modulations for easy fiber identification. This is standard equipment on all models - a chargeable option on most other
OTDRs.
In place of the standard power meter, the MT9083A offers
four optional optical power meters; one supports both SM
and MM fibers (MT9083A-003,006) while the others feature
higher measurement range for SM only applications (-004,
-005). When measurement of high optical powers, typically
more than +20 dBm (like those used by CATV companies)
is required, power meter (Option 005) using an optical
integrator sphere can be used to make long-term measurements with high stability at levels above +30 dBm.
Standard Integrated Power Meter
In the base unit, the OTDR port also functions as an integrated power meter for verification of optical power levels.
Additional power meter options are available for higher
power transmissions and loop-back testing.
Data Table for Saved Results
Loss test set measurements for multiple wavelengths can
be saved into a results table for easy comparison and
archiving. The table can also be saved as a text file and
exported to a PC spreadsheet program for further manipulation or integration into a standard company template.
Visual Laser Source for easy fault location and
fiber identification
A Visible Light Source is useful for tracking down bad connections, splices and fiber management issues such as
macrobends. The optional Visible Light Source is factory
installed in the MT9083A and features up to 5 km (3 miles)
of operation.
Optical Access Network QoS Evaluation Using IP Testing (Planned)
(to be released in 2007)
Faults that cause drops in FTTx service speed are handled differently according to whether the cause is outside or inside
the building. In addition, business users are starting to think about guaranteed bandwidth services and higher-speed gigabit
services. The MT9083A has a built-in IP Network Connection Check function that can be used for both optical fibers and
optical access QoS evaluation.
Throughput Measurement and Frame Counter
Connection and Ping Tests
The MT9083A has a two-way throughput measurement
function for efficient evaluation of guaranteed bandwidth
services. When an MT9083A is connected to each end of
the service, both the upload and download speeds can be
evaluated. And since the built-in frame counter functions
can be used to measure received frame types and to count
error frames, network usage efficiency can be measured
easily too.
The first step in testing a service is to verify continuity. The
built-in IP Connection Test Function supports both PPPOE
and DHCP services.
FTTx Download Speed Evaluation
FTTx service performance is easily evaluated from the
download throughput. Previous evaluation systems were
always limited by the PC performance (CPU speed, memory
size, OS, load) and never provided accurate measurements.
Using the MT9083A Download Throughput Measurement
function frees the results from the impact of PC performance and provides accurate results. This allows the causes
of drops in FTTx service speeds to be pinpointed to the network side or the user’s PC side.
Gigabit Ethernet Support
The MT9083A has an optional built-in 1000Base-T electrical
interface for evaluating Gigabit Ethernet throughput (up to
full line rate) for verifying performance on increasing common Gigabit Ethernet service
Faults Identified
When issues are present, possible causes are displayed
on-screen to help isolate the source of the problem.
7
Specification
MT9083A ACCESS Master
Item
Dimensions and Mass
General Specifications
Size: 270 (W) x 165 (H) x 61 (D) mm
Without protector (option 010)
Weight: 2.2 kg (4.8 lbs) including battery
Size: 284 (W) x 200 (H) x 77(D) mm
With protector (option 010)
Weight: 2.9 kg (6.4 lbs) including battery
Display
6.5 inch TFT-LCD (640x480, with backlight, transparent type)
Data Storage
Internal memory: 20 MB (~1000 traces),
External memory (USB): ~30,000 traces with 512 MB
Interface
Power Supply
Battery
Power Saving Functions
Vertical Scale
IOR Setting
Units
Languages
Sampling Points∗2
Sampling Resolution∗3
Reflectance Accuracy
Distance Accuracy
USB 1.1, TypeA x1 (memory), Type Bx1 (USB mass storage).
12 VDC,
100 to 240 VAC, Allowable input voltage range: 90 to 264 V, 50/60 Hz
Type: Lithium ion
Operating Time∗1: 8 hours
Recharge Time: <5 hours (power off)
Backlight off: disable/1–99 minutes
Auto shutdown: disable/1–99 minutes
0.05, 0.125, 0.25, 0.5, 1.25, 2.5, 5, 6.5 dB/div
1.000000 - 1.999999 (0.000001steps)
km, m, kft, ft, mi
user selectable (English, French, German and Simplified Chinese - contact Anritsu for availability of others)
Normal: 5001, High density: 20001 or 25001
5 cm (min)
Single mode: ±2 dB, multimode: ±4 dB
±1 m ±3 x measurement distance x 10 -5 ± marker resolution (excluding IOR uncertainty)
Distance Range
Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200 km (except 780 nm: 0.5, 1, 2.5 km)
Multimode: 0.5, 1, 2.5, 5, 10, 25, 50, 100 km
Testing Modes
Fault locate: provides end/break location, end to end loss, fiber length
Standard OTDR: user selectable automatic or manual set-up
Construction OTDR: automated, multi-wavelength testing∗4
Light source: stabilized light source (CW, 270 Hz, 1 kHz, 2 kHz output)
Loss test set (optional): power meter and light source
Power Meter
Visual fault locator (optional): visible red light for fiber identification and troubleshooting
Fiber Event Analysis
Auto or manual operation, displayed in table format
User defined PASS/FAIL thresholds:
- reflective and non-reflective events: 0.01 to 9.99 dB (0.01 dB steps)
- reflectance: 20.0 to 60.0 dB (0.1 dB steps)
- fiber end/break: 1 to 99 dB (1 dB steps)
Number of detected events: up to 99
Macrobend detection
OTDR Trace Format
Other Functions
Environmental Conditions
EMC
LVD
Telcordia universal. SOR, issue 2 (SR-4731)
Real time sweep∗5: 0.15 second
Loss modes: 2 point loss, dB/km, 2 point LSA, splice loss, ORL
Averaging modes: timed (1– 3600 seconds)
Live Fiber detect : verifies presence of communication light in optical fiber
Connection check: Automatic check of OTDR to FUT connection quality
Trace overlay and comparison
Operating temperature and humidity: 0 to +40C,<80% (non-condensing)
Storage temperature and humidity: –20 to +60C, <80% (non-condensing)
Vibration: Conforming to MIL-T-28800E Class 3
Dust proof: MIL-T-28800E Class 2
Drip proof: IP51 (IEC 60529), JIS C 0920 TYPE I
EN61326:1997+A1:1998+A2 : 2001+A3:2003 (Class A, Annex A), EN61000-3-2:2000(Class A)
EN61010-1:2001 (Pollution Degree 2)
Notes
∗1 :Typical, backlight off, sweeping halted at 25˚C, 6 hours typical continuous testing
∗2 : Either high density value is selected depending on distance range
∗3 : Except 780 nm
∗4 : To be planned
∗5 : Sampling mode normal. Except models 062, 068 -1 second or less
8
OTDR Specifications
Model
Wavelength∗6
Fiber Type
Pulsewidth
050
1310 ±30 nm
38.5 dB
052
1650 ±5 nm
33.5 dB
051
053
054
1550 ±30 nm
37 dB
1310/1550 ±30 nm
056
1310/1490/1550 ±30 nm
1310/1550/1625 ±30 nm Single Mode
(SMF) 10/125 µm
1310/1490/1550/1625 ±
ITU-T G.652
30 nm
057
058
059
060
061
062
≤5/5.5 m
≤5.5/6.5 m
37.5/36/33.5 dB
3, 10, 20, 50, 100,
200, 500, 1000,
2000, 4000, 10000,
20000ns
≤5 m
≤6.5 m
36/33.5 dB
1310/1550 ±30 nm,
1650 ±5 nm
Deadzone
(Backscatter)∗10
≤5.5 m
38/36.5 dB
1550 ±30/1650 ±5 nm
055
Deadzone
(Fresnel)∗9
Dynamic Range∗7,8
≤1 m
(80 cm typical)
36/34.5/34.5 dB
36/34.5/31.5 dB
≤5/5.5/6 m
≤6/6.5/6.5 m
≤6/6.5/7.5 m
34/32.5/32.5/29.5 dB
≤7/7.5/7.5/8.5 m
1310/1550/1625 ±30
nm, 1383 ±2 nm
34/32.5/29.5/33 dB
≤7/7.5/8.5/7.5 m
1490 ±30 nm
1625 ±30 nm
36.5 dB
≤5.5 m
780 ±20 nm
33.5 dB
8 dB (10 ns)
068
780 ±20/1550 ±30 nm
063
1310/1550 ±30 nm,
850/1300 ±30 nm
064
850/1300 ±30 nm
065
850 ±30 nm
1550 nm above
780 nm: 5, 10 ns
HYBRID
(SMF/MMF)
≤1 m
1550 nm:
(80 cm typical)
8/36.5 dB
Same as SMF &
MMF
3, 10, 20, 50, 100,
200, 500,1000,
Multimode (MMF) 2000, 4000 ns
62.5/125 µm
850 nm: Not
Support 1000, 2000,
4000ns
≤6.5 m
≤1 m
38/36.5 dB,
28/27 dB
≤1 m
(80 cm typical)
28/27 dB
28 dB
≤7 m
≤7/5.5 m
≤5/5.5 m,
≤4/5 m (3/4 m typical)
≤4/5 m (3/4 m typical)
≤4 m (3 m typical)
IEC Pub 60825-1:2001 Class1: option 051,052,060,062
Laser∗11
IEC Pub 60825-1:2001 Class1 M: option 050, 053, 055, 056, 057, 058, 059, 063, 064, 065
Safety
21 CFR1040.10 Excludes deviations caused by contormance to Laser Notice N.50 (issued 27 May 2001)
Notes
∗6: 25°C, Pulse width: 1 µs (all except 850, 1300, 780 nm), 850/ 1300 nm: 100ns,
780 nm: 10ns
∗7: Pulse widths: 20 µs (Options 050 to 061, 063, 068 1310/ 1550 nm) at Distance
range: 100 km
Pulse width: 4 µs (Options 063, 064 1300 nm) at Distance range: 25 km
Pulse width: 100 ns (Options 063, 065 850 nm) at Distance range: 25 km
Pulse width: 10 ns (Options 062, 068 780 nm) at Distance range: 2.5 km
Averaging: 180 seconds, SNR=1, 25°C
∗8: Dynamic range (one-way back-scattered light), SNR = 1: The level difference
between the RMS noise level and the level where near end back-scattering
occurs.
∗9: Pulse width: 3 ns (Options 050 to 061, 063, 064, 065, 068 1550 nm)
Pulse width: 5 ns (Options 062, 068, 780 nm)
Return loss: 40 dB, 25˚C (Refer to the figure below)
∗10: Pulse width 10 ns, return loss 55 dB, Deviation ±0.5 dB, 25°C
(all except 850/1300/780 nm)
Pulse width 10 ns, return loss 40 dB, Deviation ±0.5 dB, 25°C
(850/1300/780 nm)
1.5 dB
0.5 dB
l1: Fresnel reflection
l2: Back-scattered light
l1
Level
SNR = 1
l2
∗11: Safety measures for laser products
This option complies with optical safety standards in Class 1, 1M of IEC
60825-1; the following descriptive labels are affixed to the product.
Distance
9
Light Source and Power Meter Specifications – Standard on all models ∗12
Stabilized Light Source
Standard Integrated Power Meter ∗13
(through OTDR port)
(through OTDR port)
Item
Specification
Item
Specification
Wavelength∗14
Spectral Width∗15
Fiber Type
Optical Connector
Output Power∗15
Output Stability∗16
Modes of Operation∗17
Laser Safety
Same as OTDR
Maximum Input
5 nm (1310 nm)
≤10 nm (1490/1550/1625 nm),
Measurement Range
≤3 mn (1650 nm),≤1 nm (1383 nm)
Same as OTDR
+10 dBm
–50 to –5 dBm
Fiber Type
Same as OTDR
–5 ±1.5 dBm
Optical Connector
Accuracy∗18
CW, 270 Hz, 1 kHz, 2 kHz
Supported Wavelengths
±6.5%
1310, 1550, 1625 nm plus
∗ 1490 nm (056, 058, 060)
∗ 1383 nm (059)
∗ 1650 nm (050, 051, 053, 054, 055, 057, 061)
Store reference, loss table
Same as OTDR
±0.1 dB
Same as OTDR
Same as OTDR
Features
Loss Test Set Specifications – Optional on all Models∗13
Power meters (003, 004, and 005, 006)
Optical Power Meter (Option 003, 004, 005, 006)∗12
Option Number
Fiber Type
Measurement Range∗19
Wavelength Range
MT9083A-003
MT9083A-006
Single Mode: 10/125 µm
(G.652),
Multimode: 62.5/125 um
+3 to –70 dBm∗20
MT9083A-004
+23 to ­–50 dBm
750 to 1700 nm
Calibrated Wavelengths 850, 1300, 1310, 1383, 1490, 1550, 1625, 1650 nm
Optical Connector
Universal – uses MA9005B
adapters
Accuracy∗21
±5%
Features
Store reference, loss table
Modulation
MT9083A-005
Single Mode: 10/125 µm (G.652), Single Mode:10/125 um
Single Mode: 10/125 µm
Multimode: 62.5/125 um
(G.652)
(G.652)
∗PC only for UPC connector
∗PC only for UPC connector
+30 to –43 dBm
1200 to 1700 nm
1310, 1383, 1490, 1550, 1625, 1650 nm
Universal – uses JXXXX adapters
(same as OTDR)
Universal – uses MA9005B
adapters
CW, 270 Hz, 1 kHz, 2 kHz
Visible Light Source (Option 002)
Central Wavelength
650 nm ±15 nm (at 25˚C)
Optical Output
0 ±3 dBm (CW)
Output Optical Fiber
10/125 µm, SMF (ITU-T G.652)
Optical Connector
2.5 mm universal
Laser Safety∗21
IEC Pub 60825-1Class 3R, 21 CFR1040.10 Excludes deviations caused by conformance to Laser Notice
N.50 (issued 27 May 2001)
Environmental
Same as OTDR
Notes
∗12: Some models do not support built-in light source and power meter
(See next page)
∗13: If option 003, 004 or 005 is ordered, the standard integrated power meter
is not available
∗14: Option 059:1383 ±20 m
∗15: CW, 25˚C
∗16: CW, 0 to 40˚C (±1˚C) difference between max/min. values over 1 minute,
SM fiber 2 m
∗17: Modulation +1.5% with 10 minute warm up
∗18: CW input, –20 dBm At 1550 nm, 23˚C ±2 Using Master FC connector
∗19: Peak power, subtract 3 dB for modulated tones
∗21: CW, model 003: At­­–10 dBm 1310/ 1550 nm,
At–10 dBm 850 nm 25˚C
model 004/005: At 0dBm 1310 and 1550 nm
Using Master FC connector
∗22: Safety measures for laser products
This option complies with optical safety standards in Class 3R of IEC
60825-1; the following descriptive labels are affixed to the product.
∗20: +3 to –60 dBm (Option 006 @850 nm)
10
Standard Light Source and Power Meter Built-in
LS: MT9083A standard built-in stabilized light source, OPM: MT9083A standard built-in optical power meter
MT9083A-050
Model
1310 nm SM
LS
√
OPM
√
MT9083A-052
1650 nm SM
√
√
—
√
√
√
MT9083A-051
MT9083A-053
MT9083A-054
MT9083A-055
MT9083A-056
MT9083A-057
MT9083A-058
MT9083A-059
Optical Port
1550 nm SM
1310/1550 nm SM
1550 nm SM
1650 nm SM
1310/1550 nm SM
1650 nm SM
1310/1490/1550 nm SM
1310/1550/1625 nm SM
1310/1490/1550/1625 nm SM
1310/1550/1625/1383 nm SM
√
√
√
√
√
√
√
√
Model
MT9083A-065
√
MT9083A-068
√
√
Voltage, capacity
850/1300 nm MMF
√
—
—
√
—
√
1310/1550 nm SM
850 nm GI
780 nm SM
1550 nm SM
√
√
√
√
—
AC adapter: Z0933A
Lithium Ion secondary battery
Rated AC input
11.1 V, 4200 mAh
Rated DC output
Charging: +5 to +30˚C
12 Vdc, 3 A
Operating temperature:
Discharging: –20 to +60˚C
Environmental
conditions
Storage: –20 to +50˚C, ≤90%RH
0 to +40˚C, 20 to 80% R.H.
Storage temperature:
–20 to +80˚C, 10 to 95% R.H.
MT9083A-001
Name
IP Network Connection Check Function
Measurement IF
10BASE-T/100BASE-TX : 1port
IF Speed
100 to 240 Vac, 50/ 60 Hz
Dimensions and mass 60 (W) x 34 (H) x 122 (D) mm, 305 g typ
Model
MT9083A-011
Gigabit Ethernet Upgrade
10BASE-T/100BASE-TX/1000BASE-T : 1 port
10M/100M Full, 10M/100M Half, Auto negotiation, Auto MDI/MDI-X
Connectivity Check
Connection mode
VLAN
OK/NG Judgment
PPPoE, DHCP, Manual
VLAN setup is possible in the DHCP Mode and Manual Mode. Single VLAN tag is supported.
VID: 1 to 4094, COS: 0 to 7
Connection Test
Ping Test
Trace Route Test
Can be executed after the connection is established by using the Connectivity Check function.
Download throughput measurement
Download file size
Download throughput value
Can be performed after the connection is established by using the Connectivity Check function.
The full wire rate is supported.
Throughput measurement
Frame size
Can be performed after the connection is established by using the Connectivity Check function.
64, 128, 256, 512, 768, 1024, 1280, 1518, 9018, 9618 : The frame size 9018 and 9618 can be selected
when the link speed is 1000M.
1 to 100% of the line band (100% at full-wire rate), in steps of 1%
5, 10, 15, 20, 30, 60, 180, 300 s
1% or 5% of the line band
0, 0.01, 0.1, 1, 5, 10%
Transmit Rate
Transmit Duration Time
Resolution
Loss Tolerance
Counter measurement
Measurement time
Frame type
√
√
Dimensions and mass 53 (W) x 19 (H) x 215 (D) mm, 360 g typ.
Operating temperature
—
√
1625 nm SM
√
Battery pack
Battery
850/1300 nm MMF
—
√
780 nm SM
MT9083A-064
√
OPM
√
MT9083A-062
MT9083A-063
√
LS
√
1490 nm SM
MT9083A-061
√
Optical Port
MT9083A-060
Number of times: 1 to 999, Timeout Threshold: 1 to 60 s
Timeout Threshold: 2 to 60 s, Hops: 1 to 255
Up to 1 GB
Download file size [bits] / Download time [s]
1 to 720 min, in steps of 1 min.
All frame, Only PPPoE frame, Only VLAN frame
11
Ordering Information
Please specify model/order number, name and quantity when ordering.
1) Specify Base Unit
Includes ACCESS Master OTDR, AC charger/adapter, line cord, battery pack (1) and printed user’s manual.
Model/ Order No.
Description
MT9083A
ACCESS Master base unit, STANDARD display
MT9083A1
ACCESS Master base unit, Enhanced display
2) Select Optical Configuration
Includes choice of OTDR connector adapters – select in step 5 below.
Model/Order No.
Wavelength
Application
MT9083A-050
1310 nm, single mode
General-purpose model for construction, maintenance and fault location
MT9083A-051
1550 nm, single mode
General-purpose model for construction, maintenance and fault location
MT9083A-052
1650 nm, single mode
In-service measurement – integrated filter to block transmissions
MT9083A-053
1310/1550 nm, single mode
General-purpose model for construction, maintenance and fault location
MT9083A-054
1550 nm & 1650 nm, SM
MT9083A-055
1310/1550 nm & 1650 nm, SM
General-purpose models for construction, maintenance and fault location
plus In-service measurement – integrated filter to block transmissions
MT9083A-056
1310/1490/1550 nm, SM
General-purpose plus 1490 nm for FTTx/PON applications
MT9083A-057
1310/1550/1625 nm, SM
General-purpose plus enhanced macrobend detection at 1625 nm
MT9083A-058
1310/1490/1550/1625 nm, SM
General purpose for any application or full spectrum characterization
MT9083A-059
1310/1383/1550/1625 nm, SM
General-purpose plus supports Water Peak testing at 1383 nm
MT9083A-060
1490 nm, single mode
FTTx/PON testing
MT9083A-061
1625 nm, single mode
Enhanced macrobend detection
MT9083A-062
780 nm, single mode
For troubleshooting live FTTx/PON networks
MT9083A-068
780 &1550 nm, single mode
For troubleshooting live FTTx/PON networks plus general testing
MT9083A-063
850/1300 nm MM, 1310/1550 nm SM
Best unit for contractors or anyone who installs or maintains hybrid networks
MT9083A-064
850/1300 nm, multimode
Multimode fiber model
MT9083A-065
850 nm, multimode
Multimode fiber model
3) Select Factory Installed Options
Must be added as separate, chargeable line items.
Model/Order No.
Description
MT9083A-010
Protector option (includes rubber bumpers, display cover and shoulder strap)
MT9083A-001
IP Network Connection Check Function
MT9083A-011
Gigabit Ethernet Upgrade (requires option MT9083A-001)
12
With Protector option -010
Without Protector option -010
4)Select Loss Test Set Options
Optical Power Meter
Must be added as separate, chargeable line items.
Description
Model/Order No.
MT9083A-004
SMF Optical Power Meter (UPC only)
MT9083A-005
SMF High Power Optical Power Meter
MT9083A-006
SMF/MMF Optical Power Meter (UPC only)
Visible Light Source
Model/Order No.
MT9083A-002
Description
Visible Laser Diode
5) Select Connector Types
The ACCESS Master MT9083A can be optioned to feature up to three optical ports – single mode OTDR,
multimode OTDR and an optical power meter (options -003, -004 and -005). Selecting a single connector
code below will populate all optical ports with that connector type or customer can select different adapters by
specifying the adapter for each of the three optical ports – see examples below.
Optical Connectors
One adapter type is provided for each port at no charge - must be added as separate line items.
NOTE: FC-APC and SC-APC are not available for MM OTDR or optical power meter.
Model/Order No.
MT9083A-025
MT9083A-026
MT9083A-033
MT9083A-037
Description
FC-APC connector - single mode
OTDR only (additional charge applies)
SC-APC connector - single mode
OTDR only (additional charge applies)
Model/Order No.
Description
MT9083A-038
ST connector
MT9083A-039
DIN connector
LC connector
MT9083A-040
FC connector
MT9083A-043
SC connector
HMS-10/A connector
NOTE: UPC and APC connectors are not compatible – the internal optics are different and must be specified at time or order.
UPC Ultra Physical Contact
APC Angled Physical Contact
13
Examples:
1) MT9083A-053 with MT9083A-004 power meter option
Customer can specify “MT9083A-040 for the SM OTDR” port and “MT9083A-037 for the OPM” port at no charge.
2) MT9083A-063 with MT9083A-003 power meter option
Customer can specify “MT9083A-040 for the SM OTDR” port, “MT9083A-037 for the MM OTDR” port and
“MT9083A-037 for the OPM” port at no charge.
3) MT9083A-053 with no options
Customer can specify “MT9083A-026 for the SM OTDR” port however an additional charge applies.
6) Select Accessories & Replacement Items
Model/Order No.
Accessories
Must be added as separate, chargeable line items.
W2839AE
Hardcopy MT9083A operation manual
B0583A
Hard carry case for MT9083A - attaché style
B0582A
B0549
Description
Soft carrying case
Hard carry case for MT9083A with handle and wheels
Z0921A
Replacement battery pack for MT9083A
Z0933A
Replacement AC charger/adapter
Z0942A
External battery charger
J1295
NETWORKS
MT9083A-ES210
MT9083A-ES310
Car plug cord
PC emulation software for data analysis and reporting
12 month extended warranty
24 month extended warranty
Peripherals
BL-80R2
Thermal printer kit (must also order BL-100W AC adapter, J1314 printer cable and BL-80-30 paper rolls)
J1314
Printer cable for BL-80R2 printer
BL-100W
BL-80-30
MT9083A-101
MT9083A-111
MT9083A-110
MT9083A-103
MT9083A-104
MT9083A-105
MT9083A-102
AC adapter for BL-80R2 printer
Printer paper for BL-80R2 Thermal Printer (10 rolls/set)
Retrofit Options for existing units – unit must be returned to authorized service center
IP Network Connection Check Function (Retrofit)
Gigabit Ethernet Upgrade (Retrofit - requires option MT9083A-001 or MT9083A-101)
Protector Option (Retrofit)
SMF/MMF Optical Power Meter (Retrofit)
SMF Optical Power Meter (Retrofit)
SMF High Power Optical Power Meter (Retrofit)
Visible LD (Retrofit)
Type
LC
Replacement Adapters
OTDR and Power meters
(MT9083A-004 and MT9083A-006)
J1270
Power meter (MT9083A-005 only)
MA9005B-33
J0617B
MA9005B-37
ST
J0618D
MA9005B-38
HMS-10A
J0618F
MA9005B-43
FC
Angled FC (AFC)
DIN
SC (UPC or APC)
Soft carrying case (B0582A)
N/A
J0739A
MA9005B-39
J0618E
MA9005B-40
J0619B
Hard carrying case (B0583A)-Attache style
14
Hard carrying case (B0549)
Related Anritsu Products
CMA50 Power Meters, Light Sources
and Loss Test Sets
CMA 5000 Multilayer Testing Platform
CMA5 Optical Power Meter and Light
Source
CMA3000 Mobile and Fixed Access
Network Tester
The CMA5000 is the industry's premier test and measurement solution featuring Gigabit Ethernet, DWDM, SONET/
SDH, OTDR, ORL, PMD and CD applications. Through its
open-architecture design, the CMA5000 offers the highest
performance measurement applications in one powerful,
modular platform.
Fast, accurate and easy-to-use, Anritsu's CMA50 line
of Light Sources, Power Meters and Loss Test Sets are
designed for attenuation and throughput measurements
of fiber optic links. With up to four stable lasers in the
same unit and power meter calibrated to 26 different wavelengths, CMA50 meets any testing requirement from FTTx
PON networks, to CWDM to long haul telephony links to
multimode LAN, and CATV. CMA 50 makes your measuring experience comprehensive yet simple and error free
with tone detection, auto wavelength switching mode, fully
automatic bi-directional testing option, Optical Return Loss
(ORL) option, Pass/Fail threshold analysis, large capacity
for test results storage, & RJ45 interface Network Testing
option.
The CMA5 Series Power Meters are ideal for attenuation
and power throughput measurements on point-to-point fiber
optic links. The CMA5 Series Light Sources provide an
economical and stable laser source for use in point-to-point
attenuation measurement. They feature a rugged design,
built to withstand the difficult testing environment of fiber
optic cable installation and maintenance.
CMA 3000 is designed specifically for field technicians who
install and maintain mobile-access and fixed-access networks. The CMA 3000 is a powerful tool for a wide range
of applications, including fast first-aid troubleshooting to
comprehensive, in-depth and all-layer analysis of transmission problems. The basic CMA 3000 configuration, with its
two 2 Mbps receivers and transmitters, supports framed
and unframed testing and monitoring of 2 Mbps systems.
15
Specifications are subject to change without notice.
Anritsu Corporation
5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan
Phone: +81-46-223-1111
Fax: +81-46-296-1264
• U.S.A.
Anritsu Company
1155 East Collins Blvd., Suite 100, Richardson,
TX 75081, U.S.A.
Toll Free: 1-800-267-4878
Phone: +1- 972-644-1777
Fax: +1-972-671-1877
• Canada
Anritsu Electronics Ltd.
700 Silver Seven Road, Suite 120, Kanata,
Ontario K2V 1C3, Canada
Phone: +1-613-591-2003
Fax: +1-613-591-1006
• Brazil
Anritsu Eletrônica Ltda.
Praca Amadeu Amaral, 27 - 1 Andar
01327-010-Paraiso-São Paulo-Brazil
Phone: +55-11-3283-2511
Fax: +55-11-3288-6940
• U.K.
Anritsu EMEA Ltd.
200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K.
Phone: +44-1582-433200
Fax: +44-1582-731303
• France
Anritsu S.A.
9 Avenue du Québec, Z.A. de Courtabœuf
91951 Les Ulis Cedex, France
Phone: +33-1-60-92-15-50
Fax: +33-1-64-46-10-65
• Germany
Anritsu GmbH
Nemetschek Haus, Konrad-Zuse-Platz 1
81829 München, Germany
Phone: +49-89-442308-0
Fax: +49-89-442308-55
• Italy
• India
Anritsu Pte. Ltd.
India Branch Office
Anritsu S.p.A.
Via Elio Vittorini 129, 00144 Roma, Italy
Phone: +39-6-509-9711
Fax: +39-6-502-2425
Unit No. S-3, Second Floor, Esteem Red Cross Bhavan,
No. 26, Race Course Road, Bangalore 560 001, India
Phone: +91-80-32944707
Fax: +91-80-22356648
• Sweden
Anritsu AB
Borgafjordsgatan 13, 164 40 KISTA, Sweden
Phone: +46-8-534-707-00
Fax: +46-8-534-707-30
• Finland
Anritsu AB
Teknobulevardi 3-5, FI-01530 VANTAA, Finland
Phone: +358-20-741-8100
Fax: +358-20-741-8111
• Denmark
Anritsu A/S
Kirkebjerg Allé 90, DK-2605 Brøndby, Denmark
Phone: +45-72112200
Fax: +45-72112210
• Spain
Anritsu EMEA Ltd.
Oficina de Representación en España
Edificio Veganova
Avda de la Vega, n˚ 1 (edf 8, pl 1, of 8)
28108 ALCOBENDAS - Madrid, Spain
Phone: +34-914905761
Fax: +34-914905762
• P.R. China (Hong Kong)
Anritsu Company Ltd.
Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza,
No. 1 Science Museum Road, Tsim Sha Tsui East,
Kowloon, Hong Kong
Phone: +852-2301-4980
Fax: +852-2301-3545
• P.R. China (Beijing)
Anritsu Company Ltd.
Beijing Representative Office
Room 1515, Beijing Fortune Building,
No. 5, Dong-San-Huan Bei Road,
Chao-Yang District, Beijing 10004, P.R. China
Phone: +86-10-6590-9230
Fax: +86-10-6590-9235
• Korea
Anritsu Corporation, Ltd.
8F Hyunjuk Building, 832-41, Yeoksam Dong,
Kangnam-ku, Seoul, 135-080, Korea
Phone: +82-2-553-6603
Fax: +82-2-553-6604
• Australia
• United Arab Emirates
Anritsu Pty. Ltd.
Anritsu EMEA Ltd.
Dubai Liaison Office
P O Box 500413 - Dubai Internet City
Al Thuraya Building, Tower 1, Suit 701, 7th Floor
Dubai, United Arab Emirates
Phone: +971-4-3670352
Fax: +971-4-3688460
• Singapore
Anritsu Pte. Ltd.
60 Alexandra Terrace, #02-08, The Comtech (Lobby A)
Singapore 118502
Phone: +65-6282-2400
Fax: +65-6282-2533
Unit 21/270 Ferntree Gully Road, Notting Hill,
Victoria 3168, Australia
Phone: +61-3-9558-8177
Fax: +61-3-9558-8255
• Taiwan
Anritsu Company Inc.
7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan
Phone: +886-2-8751-1816
Fax: +886-2-8751-1817
Please Contact:
070605
Printed on 70%
Recycled Paper
Catalog No. MT9083A-E-A-1-(3.00)
Printed in Japan
2007-7 MBP/CDT