Confidential
Marketing Guide
VariTrane™
Parallel and Series
Fan-PoweredTerminal Units
DATE: October 2002
ORDER No.: VAV-SLM005-EN
Catalog Reference:
VAV-PRC005-EN
Parallel Contents
Introduction
3
Parallel Product Features
4–7
Parallel Feature Evaluation
8–11
Parallel Model Comparison
12
Parallel Quick Competitive Comparison
13–14
Parallel Primary Inlet Airflow Ranges (Cfm)
15
Parallel Valve/Fan Combinations
16
Parallel Size Comparison
17
Parallel Fan Airflow Comparison
18–21
Parallel Pressure Requirements
22–24
Parallel Hot Water Coil
25–29
Parallel Electric Coil
30–32
Series
Contents
Series Contents
Series Product Features
33–36
Series Feature Evaluation
37–41
Series Model Comparison
42
Series Quick Competitive Comparison
43–44
Series Primary Inlet Airflow Ranges (Cfm)
45
Series Valve/Fan Combinations
46
Series Size Comparison
47
Series Fan Airflow Comparison
48–51
Series Pressure Requirements
52–55
Series Hot Water Coil
56–64
Series Electric Coil
65–69
ECM Quick Competitive Comparison
70
ECM Valve/Fan Combinations
71
ECM Size Comparison
72
ECM Fan Airflow Comparison
73–74
ECM Hot Water Coil
75–78
Series Electric Coil
79–80
References
© 2002 American Standard, Inc. All rights reserved
81
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
2
Introduction
This Fan-Powered marketing guide is divided into two sections: Fan-Powered
Parallel and Fan-Powered Series.The guide is a performance and feature
comparison ofTrane,Titus, Enviro-Tec (ETI), Price, and Nailor.
Along with just comparing the performance the guide also shows advantages and
disadvantages of theTrane product vs. the competition’s and explains key selling
features of the product.This is done in the beginning pages of each section titled
Product Features.This Product Features page shows whereTrane is advantaged,
equal, and disadvantaged.There are also corresponding page numbers that
indicate where you can find more information regarding the features.
Example:
Page # where more supporting
data can be found
Green
=Trane is advantaged ..................................................... #
Yellow
=Trane is equal .............................................................. #
Red
=Trane is disadvantaged .................................................... #
3
Product
Features
Trane
VPCF,VPWF, and VPEF
— 7 fan sizes available, 210–2500 cfm (range based on .25 in. wg DSP)
— 19 valve/fan combinations
— Minimum 14 measuring point flow ring
— Metal encapsulated insulation edges standard for IAQ
— Rugged contractor tough unit construction
— Factory-commissioned controls
— Factory calibrated
— UL and ARI listed
— Factory-mounting customer controls availability
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, attenuators, and
various ‘IAQ’ linings
Titus
DTQP, ETQP, and PTQP
— 5 fan sizes available, 200–2650 cfm (range based on .25 in. wg DSP)
— 19 valve/fan combinations
— 5-point flow cross sensing device
— 2 casing sizes
— SCR fan speed control
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, attenuators, and
various IAQ linings
Green
= Trane is advantaged
Yellow
= Trane is equal
Red
= Trane is disadvantaged
Trane vs. Titus
Page
Encapsulated edges .................................................................................................. 8
Factory-commissioned controls ............................................................................... 11
More measuring points on our flow ring .............................................................. 8, 13
ARI certified units ............................................................................................... 10, 13
Air filter ................................................................................................................ 8, 13
Filter frame ........................................................................................................... 8, 13
Fan disconnect ..................................................................................................... 8, 13
Hanger brackets ................................................................................................... 8, 13
Number of valve/fan combinations ..................................................................... 13, 16
Unit access ............................................................................................................. 13
Fan cfm ranges ............................................................................................. 14, 18–21
SCR fan speed control ............................................................................................ 14
80/20 nickel/chrome wire ......................................................................................... 14
Dust tight enclosure for electric Reheat ................................................................... 14
kW availability ............................................................................................... 10, 13, 30
Analog controls ...................................................................................................... 10
Steam coils ............................................................................................................. 13
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
4
Parallel
Fan-Powered
Product
Features
Trane
VPCF, VPWF, and VPEF
— 7 fan sizes available, 210–2500 cfm (range based on .25 in. wg DSP)
— 19 valve/fan combinations
— Minimum 14 measuring point flow ring
— Metal encapsulated insulation edges standard for IAQ
— Rugged contractor tough unit construction
— Factory-commissioned controls
— Factory calibrated
— UL and ARI listed
— Factory-mounting customer controls availability
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, attenuators, and
various ‘IAQ’ linings
Enviro-Tech (ETI)
VFR, VFR-WC, and VFR-EH
— 6 fan sizes available, 100–2400 cfm (range based on .25 in. wg DSP)
— 19 Valve/Fan Combinations
— 12-point Flow Star™ flow sensing device, (available for size 6” and above)
— Mechanically fastened insulation
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, attenuators, and
various IAQ linings
Green
= Trane is advantaged
Yellow
= Trane is equal
Red
= Trane is disadvantaged
Trane vs. ETI
Page
Transformer ......................................................................................................... 14
Factory-commissioned controls ........................................................................... 11
Manual secondary cutout standard with electric reheat .................................... 9, 13
Flow ring on smaller units (5" inlet) / ETI uses a flow bar ................................... 8, 13
Air filter ............................................................................................................ 8, 13
Filter frame ....................................................................................................... 8, 13
Fan disconnect ................................................................................................. 8, 13
Hanger brackets ............................................................................................... 8, 13
Dual-wall insulation option ................................................................................... 13
External actuator .................................................................................................. 13
Damper position indicator .................................................................................... 13
Fan cfm range ........................................................................................... 14, 18–21
Line fuses for electric heat standard for ETI .......................................................... 14
SCR electric heat control ................................................................................. 11, 14
120-volt electric heat option .................................................................................. 14
Electric reheat kW/voltage/staging options ................................................ 10, 30–31
VAV-SLM005-EN
5
Parallel
Fan-Powered
Product
Features
Trane
VPCF,VPWF, and VPEF
— 7 fan sizes available, 210–2500 cfm (range based on .25 in. wg DSP)
— 19 valve/fan combinations
— Minimum 14 measuring point flow ring
— Metal encapsulated insulation edges standard for IAQ
— Rugged contractor tough unit construction
— Factory-commissioned controls
— Factory calibrated
— UL and ARI listed
— Factory-mounting customer controls availability
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, attenuators, and
various ‘IAQ’ linings
Price
FDV, FEV, FPV
— 5 fan sizes available, 220–2900 (range based on .25 in. wg DSP)
— 14 valve/fan combinations
— Factory calibrated to job requirements
— SP-200 multi-point flow sensor with 12 measuring points
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, attenuators, and
various insulation
Green
= Trane is advantaged
Yellow
= Trane is equal
Red
= Trane is disadvantaged
Trane vs. Price
Page
Valve/fan combinations ...................................................................................... 13, 16
Lower damper leakage ............................................................................................ 13
More measuring point on our flow ring ................................................................ 8, 13
Water coil access is standard with hot water reheat ................................................. 13
Air filter ................................................................................................................ 8, 13
Filter frame ........................................................................................................... 8, 13
Fan disconnect ..................................................................................................... 8, 13
Hanger brackets ................................................................................................... 8, 13
Manual secondary cutout for electric reheat ......................................................... 9, 13
Factory-commissioned DDC controls ...................................................................... 11
Electric heat wire type ............................................................................................. 14
Perforated liner ................................................................................................... 11, 13
SCR electric heat control ..................................................................................... 11, 14
120-volt electric heat ................................................................................................ 14
kW range ................................................................................................. 10, 13, 30–31
Fan cfm range ............................................................................................... 14, 18–21
Attenuators ............................................................................................................. 14
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
6
Parallel
Fan-Powered
Product
Features
Trane
VPCF, VPWF, and VPEF
— 7 fan sizes available, 210–2500 cfm (range based on .25 in. wg DSP)
— 19 valve/fan combinations
— Minimum 14 measuring point flow ring
— Metal encapsulated insulation edges standard for IAQ
— Rugged contractor tough unit construction
— Factory-commissioned controls
— Factory calibrated
— UL and ARI listed
— Factory-mounting customer controls availability
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, attenuators, and
various ‘IAQ’ linings
Nailor
35P, 35PW, 35PE
— 6 fan sizes available. 150–2185 cfm (range based on .25 in. wg DSP)
— 22 valve/fan combinations
— Inclined opposed blade damper design
— “Diamond Flow” multi-point averaging sensor with 8 measuring points
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coil for reheat, attenuators, and
various IAQ linings
Green
= Trane is advantaged
Yellow
= Trane is equal
Red
= Trane is disadvantaged
Trane vs. Nailor
Page
Encapsulated edges .............................................................................................. 8
Factory-commissioned controls ........................................................................... 11
Lower damper leakage .................................................................................... 11, 13
Fan cfm range ........................................................................................... 14, 18, 21
Manual secondary cutout for electric reheat ..................................................... 9, 13
ARI certified units ........................................................................................... 10, 13
Air filter ............................................................................................................ 8, 13
Filter frame ....................................................................................................... 8, 13
Fan disconnect ................................................................................................. 8, 13
Hanger brackets ............................................................................................... 8, 13
Single point power ............................................................................................... 14
Transformer standard .......................................................................................... 14
Number of valve/fan combinations ................................................................. 13, 16
SCR electric heat control ................................................................................. 11, 14
Attenuators .......................................................................................................... 14
VAV-SLM005-EN
7
Parallel
Fan-Powered
Feature
Evaluation
Hanger Brackets/Air Filter/Filter Frame/Fan Disconnect
Trane provides hanger brackets, air filter, filter frame, and a fan disconnect as
standard. WhenTrane is in control of the specifications, make sure that we are making
our competition provide these options in their bill of materials!
Metal Encapsulated Edges
All VariTrane units are complete with metal encapsulated insulation edges.This
encapsulated design arrests cut fibers and prevents erosion of the fibers into the
airstream. As a standard, our competition “butters” the edges of the exposed
insulation with an adhesive spray intended to hold the fibers together. After being
handled, and over time, the adhesive breaks down and allows fibers to escape into the
airstream. Edge spray is clearly not equivalent! Specifying VariTrane metal
encapsulated edges will force the competition to add additional dollars to their units.
Whether or notTrane is basis of design, make sure the consultant understands the
significance of metal encapsulated edges.
Suggested Spec
INSULATION EDGE TREATMENT—All cut edges of insulation shall completely enclosed by metal to arrest cut fibers and prevent erosion into the airstream.
Number of Measuring Points on our Flow Ring (How low can
you go?)
The accuracy of a flow-measuring device is determined by the lowest allowable
minimum cfm setting. Below this cfm, the VAV units will change from pressureindependent (PI) to pressure-dependent (PD) control. Because VariTrane units are
designed to integrate into a DDC control system the UCM, flow ring, and pressure
transducer create a flow measurement “system” which provides unmatched flow
performance in the VAV industry. Accuracy is +/- 5% from maximum to minimum
cfm. See pp. 11 for a comparison ofTrane vs. the competition.
Given:
A consultant is designing a space that requires 800 cfm maximum airflow. Ventilation
is determined by minimum occupancy = 8 persons. 15 cfm/person equates to 120
minimum cfm.
Using the VariTrane Quick Select (VAV-SLP001-EN), the consultant chooses an
8” inlet.
The 8" VariTrane air valve can have a minimum set as low as 110 cfm.Thus, the
120 cfm minimum is available. Competitor “N” has a minimum that stops at
150 cfm and can be no lower. Let’s look at the system/cost impact:
Find:
The efficiency impact by having a higher minimum cfm setting.
Assume:
— Unit operates for 3000 hours per year
— Unit is providing reheat 50% of the time.
— Room setpoint (winter) = 70°F
— Supply Air = 55°F
Solution:
When in reheat, the VAV unit operates at its minimum airflow. VAV systems typically
have 55°F primary air temperature. Let’s see how this 30 cfm can impact operating
costs:
Qs = 1.085 x cfm x DT
The additional energy required by competitor “N” is
1.085 x 30 cfm x (70 – 55) = 488 Btuh
This equates to 732,375 Btu per year, per 8” valve, which is an increase of 25% in
energy required to reheat the air up to room temperature.
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
8
Parallel
Fan-Powered
Feature
Evaluation
Suggested Spec
Multi-point, multi-axis flow ring or cross sensor to be furnished and installed by
terminal unit manufacturer. Single-point or flow bar sensors are not acceptable. Flow
sensing device shall be capable of maintaining airflow to within +/- 5 percent of rated
unit airflow setpoint when installed with 1.5 duct diameters straight duct, of the same
size as the primary airflow inlet, upstream from the unit.
Water Coil MBH Performance
Overall we have the highest MBH performance out of our competition.This high
performance is the result of our higher water pressure drop on the coils. Don’t let the
competition force you into a 2-row coil if our 1-row coil will satisfy the MBH
performance requirement.
Suggested Spec
HOT WATER HEATING COILS—Coils shall be factory-installed and shall consist of
aluminum-plated fins and seamless copper tubes. Fins shall have full fin collars to
provide accurate fin spacing and maximum fin-to-tube contact.Tubes shall be mechanically expanded into the fin collars. Coils shall be leak tested under water to 450
psig pressure. Supply and return water connections shall be on the same side of the
coil.
Water Coil Pressure Drop
At first glance, you will notice that theTrane VAV water coils have a higher water
pressure drop then the competition.Typically, water pressure drop of VAV terminal
units is not a concern of engineers since the units are piped in a two-pipe
configuration and the air-handler coil is in the same line.The air-handler water coil
pressure drop is what the pump(s) will be sized for.
Manual Secondary Cutout
“Electric heater shall be complete with automatic reset cutout and manual reset
cutout.The Manual reset cutout shall be capable of being reset by a switch, or push
button. Fusible links are not acceptable.”
Why is this important?
A fusible link is a small wire sized to melt when it receives more amperage than it was
designed to handle. Once melted, it can cool and complete the circuit again.This
safety issue is whyTrane no longer uses fusible links.
Additionally, finding of a replacement part for a fusible link may be difficult.Therefore,
the unit would be down for an extended period.
Control Boxes as Standard for Units with NO Controls
What we do:
Field-Installed Controls:
Approximately 50% of VAV controllers in the industry are “plenum rated”.This means
they DO NOT NEED A CONTROL ENCLOSURE. If a control enclosure is required, the
controls supplier should provide it. After all, they know the size, shape, etc. of their
controller.
If transformers, disconnects, and/or fuses are factory-installed, then a control
enclosure will be provided to house these. (A control box is available as a
design special.)
Factory-Installed Competitive Controls:
When competitive controls are installed in the factory and the controller to be
installed is a plenum-rated controller, then no control box will be provided. If the
controller is not plenum rated then a control box will be provided. (A control box is
available as a design special.)
VAV-SLM005-EN
9
Parallel
Fan-Powered
Feature
Evaluation
Analog Controls
Analog controls are a reduced cost solution for the end-user… or are they? Analog
VAV controllers have a similar cost as DDC VAV controllers. What they lack is the
ability to:
— Monitor remotely
— Provide diagnostic data
— Provide feedback to building control panel
— DDC systems can recognize something is broken before it is even noticed by the
occupants. By the time occupants notice a problem, a service technician can already
be on the way.
— Leverage energy-saving strategies such as static pressure optimization (required by
ASHRAE 90.1) or Ventilation Reset. (See www.Trane.com/commercial/issues/iaq/
ashrae.asp.com for additional details)
Acoustics
Make sure you are doing an “apples to apples” comparison. Don’t let the competition
use a less stringent sound power assumption or show cooling only information if reheat is to be used.
Sound Power–if specifying a particular spectrum shape for a particular
manufacturer, this is the same as being a proprietary specification.This is not advised.
NC (Noise Criteria)–NC level is determined by taking the sound power generated
using ARI 880-98, and applying a transfer function.The transfer function assumptions
in ARI 885-98 standard are significantly different than the 90 standard. On average, the
same unit operating at the same conditions will show a 4 NC improvement if the
older, superceded 90 standard is used. Don’t let the competition catch you in this trap.
Said another way, if your customers specified NC 40 in the space prior to the 98
standard being written, that is now equivalent to NC 44 with the current standard
ARI Certification–Are the units that are specified ARI certified?
Titus has a quantity of 19 valve/fan combinations, however on the ARI website only 14
are listed as certified units.
Nailor has a quantity of 22 valve/fan combinations listed in their catalog, however on
the ARI website only 14 of those are listed as certified units.
Trane has a quantity of 19 valve/fan combinations, 19 of which are listed on the
ARI website.
If sound is going to be critical on specific units, make sure the units that we are
comparing to are listed on the ARI website www.ariprimenet.org .
UL Rating for Electric Heat
Our units have been tested, approved, and listed with UL as an entire assembly. Most
VAV manufacturing companies have their units ETL listed in accordance with UL
standards.
Electric Reheat kW/Voltage/Staging options
To better answer this questions as to why units with electric reheat are not able to
reach certain higher kW’s on 2- and 3-stage or have certain number of stages, 3-phase
units when some are able to reach kW’s on some 1-phase, 1-stage units.There are
many reasons why, but the two major limiting factors are wire size and the units
discharge dimensions.
A heating element requires a certain length, a certain diameter, and the correct
number of elements in order to obtain the correct staging.This determines the
ohmage (resistance) needed to provide the desired kW. Since resistance and kW are
inversely proportional for a given voltage, higher kW heaters end up needing very little
element material, which means changing either the length or the diameter of the wire.
However, there are safety issues, UL and NEC regulations, and manufacturing
practices that limit the diameter from getting too small. Hence, only one alternative
exists and that is to change the length of the wire, which may not be long enough to
fill the discharge area of the heater. Filling the discharge area is important to building a
heater, because it will minimize stratification and will increase the longevity of the
heater by minimizing hot spots.
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
10
Parallel
Fan-Powered
Feature
Evaluation
Factory-Commissioning
Factory-commissioning is more than just factory-installed controls!Trane takes great
pride in being the industry leader in factory-commissioned DDC controls.The
following table differentiates these concepts and indicates where options can be
obtained (either the field, or the factory):
Factory-installed
Transformer optionally installed
X
Wires terminated in reliable/ consistent setting
X
Controller mounted
X
Electric heat contactors and fan relay wired
X
Testing of heater contactors and fan relay
Controller addressing and associated testing
Minimum & Maximum airflows (occupied/unoccupied)
Minimum & Maximum temperature setpoints
(occupied/unoccupied)
Minimum ventilation requirements
(used to calculate ventilation fraction)
Thumbwheel enable/ disable
Heating offset
Factory-commissioned
X
X
X
X
X
X
X
X
X
X
X
Factory-commissioned controllers provide the highest quality and most reliable
controllers for your VAV system. Additional testing verifies proper unit operation
including occupied/unoccupied airflow, temperature setpoints, communication link
functionality, and output device functionality. The benefits of factory-commissioning
are standard on VariTrane terminal units withTrane DDC controls.
Perforated Liners
The intended use of perforated liners was for units that had a Mylar orTedlar
insulation. Mylar andTedlar insulation was found to have long-term durability
problems and would erode into the airstream over time.The perforated liner was
designed to hold the insulation with the idea to improve acoustical performance over
a dual-wall construction.
Today, if a perforated liner is specified, it is generally used to prevent possible tearing
of the insulation during installation. However, the perforated liner will still allow air to
penetrate the insulation and loft fibers into the air stream.The best solution is to use a
foil-face or dual-wall insulation option.
SCR Electric Heat Control
Trane does not offer an option for SCR electric heat control. Our competitors use SCR
electric heat control, which is very costly. We can achieve a modulating kW operation
using our DDC controls. Using pulse-width modulation, our DDC UCM calculates
how far from setpoint the temperature is and what percentage of the electric heat is
needed.The heater is then pulsed for a specific time period to satisfy the zone.
Suggested Spec
PULSE-WIDTH MODULATION (PWM)—At heating setpoint, energize first stage of
heat.The second stage of heating shall be energized based on time and temperature
deviation from setpoint. Duty cycle these stages on a three-minute window. Stage 1
shall modulate from 0–50 percent deviation and be on continuously above 50%. Stage
2 shall modulate from 50–100 percent deviation.
Lower Damper Leakage
Our damper leakage rate is 1% @ 3 in. wg and Nailor’s leakage rate is 2% @
3 in. wg.
Nailor’s higher rate is the result of an opposed blade damper design, which generally
has a higher leakage rate.
VAV-SLM005-EN
11
Parallel
Fan-Powered
Model
Comparison
Model Comparison
VAV Terminal Units
TRANE
Parallel Fan-Powered
Cooling
VPCF
TITUS
ETI
xTQP
VFR
x = D (Digital)
E (Electronic)
P (Pneumatic)
Parallel Fan-Powered
VPWF
xTQP
VFR-WC
w/ Hot Water Reheat
x = D (Digital)
E (Electronic)
P (Pneumatic)
Parallel Fan-Powered
VPEF
xTQP
VFR-EH
w/ Electric Reheat
x = D (Digital)
E (Electronic)
P (Pneumatic)
Note: For Titus and Price replace "x" for control options letter.
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
PRICE
NAILOR
FxV
x = D (Digital)
E (Electronic)
P (Pneumatic)
FxV
x = D (Digital)
E (Electronic)
P (Pneumatic)
FxV
x = D (Digital)
E (Electronic)
P (Pneumatic)
35P
35PW
35PE
12
Parallel
Fan-Powered
Quick
Competitive
Comparison
Quick Competitive Comparison
Parallel Fan-Powered Comparison
Std. = Standard
D/S = Design Special
Product Offerings
Insulation
Opt. = Optional
N/A = Not Available
Trane
Titus
ETI
Price
Nailor
Std.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
Std.
Opt.
Opt.
Opt.
Opt.
Opt. (3/4")
N/A
N/A
Std.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
N/A
Std. (3/4")
Opt.
Opt.
Opt.
Opt.
Opt. (3/4")
Opt.
N/A
Std. (3/4")
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
N/A
Metal Encapsulated Edges
Edge Spray
Std.
N/A
Opt.
Std.
Std.
N/A
Std.
N/A
Opt.
Std.
Hanger Brackets
Std.
Opt.
Opt.
Opt.
Opt.
Air Filter
Std.
Opt.
Opt.
Opt.
Opt.
Filter Frame
Std.
Opt.
Opt.
Opt.
Opt.
Fan Disconnect
Std.
Opt.
Opt.
Opt.
Opt.
Power Fusing
Opt.
Opt.
Opt.
Opt.
Opt.
1/2" Matte-Faced Insulation
1" Matte-Faced Insulation
1/2" Foil-Faced Insulation
1" Foil-Faced Insulation
1" Dual-Wall Insulation
3/8" Fiber-Free Insulation
Perforated Liner
External Insulation
Insulation Edge Sealant
Access
Unit Access
Std.*
Std.
Std.
Std.
Std.
*Notes: Trane-Access is available through the plenum inlet on cooling only and electric re-heat units. With water coils,
access will be provided as standard.
Outlet Connection
Flange
Std.
Std.
Slip and Drive
Opt.
Opt.
*Notes: ETI only has S&D connection on HW reheat as standard.
Std.
Opt.*
Std.
Opt.
Std.
Opt.
External Actuator
Std.
Std.
Std.
Std.
Std.
Damper Position Indicator
Std.
Std.
Std.
N/A
N/A
Quantity of Valve/Fan Combinations
# of the units listed by ARI
19
19
19
14
19
19
14
14
22
14
Damper Leakage @ 3 in. wg
1%
1%
< 1%
2%
2%
Flow X
+/-5%
12
Flow Diamond
+/-5%
8
Damper/Fan Combinations
Air Measurement
Flow Sensing Device
Flow Ring
Flow Cross
Flow Star*
Accuracy
+/-5%
+/-5%
+/-5%
Min. Number Measuring Points
16
5
12
*Notes: ETI has a single-point (flow bar) measuring device for size 5" inlet.
Reheat Offering
Series / Cooling Only
Series / Hot Water Reheat
Series / Electric Reheat
Steam Coils
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
N/A
N/A
Opt.
Opt.
N/A
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
Opt.
Opt.
Opt.
N/A
.5–20.0 kW
Std.
N/A
Std.
Std.
Opt.
.5–26.0 kW
N/A
Std.
Std.
Opt.
Opt.
.5–34.0 kW
N/A
Std.
Std.
Opt.
Opt.
.5–42.0 kW
N/A
Std.
Std.
Std.
Opt.
.5–28.0 kW
N/A
Std.
Std.
Opt.
Opt.
Hot Water Coils
1-Row
2-Row
3-Row
4-Row
Electric Heat Options
kW Range
UL Listed Assembly
ETL Listed Assembly
Automatic Thermal Primary Cutout
Manual Seconday Reset
Door Interlock Disconnect
VAV-SLM005-EN
13
Parallel
Fan-Powered
Quick
Competitive
Comparison
Quick Competitive Comparison (con't.)
Parallel Fan-Powered Comparison
Std. = Standard
D/S = Design Special
Opt. = Optional
N/A = Not Available
Product Offerings
Electric Heat Options (con't.)
Trane
Titus
ETI
Price
Nailor
Line Fuse
Airflow Switch
Control Transformer
Fan Relay
Magnetic Contactors
Mercury Contactors
P.E. Magnetic Contactors
P.E. Mercury Contactors
SCR Control
Hinged Access Door
NEMA 1 Type Enclosure
Dust-Tight Enclosure
Class “A” 80/20 Nickel Chrome Elements
Class “C” 60/16/24 Ni/Ch/Fe Elements
Single-point electrical connection
115/120-volt 1-phase heater
208/240-volt 1-phase heater
277-volt 1-phase heater
347-volt 1-phase heater
480-volt 1-phase heater
208-volt 3-phase heater
240-volt 3-phase heater
480-volt 3-phase heater
575-volt 3-phase heater
600-volt 3-phase heater
Opt.
Opt.
Std.
Std.
Std.
Opt.
Opt.
Opt.
N/A
Std.
Std.
D/S
N/A
Std.
Std.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
N/A
Opt.
Std.
Std.
Std.
Std.
Opt.
Opt.
Opt.
N/A
Std.
Std.
Opt.
Std.
N/A
Std.
N/A
Opt.
Opt.
N/A
N/A
Opt.
N/A
Opt.
N/A
N/A
Std.
Opt.
Opt.
Std.
Std.
Opt.
Opt.
Opt.
Opt.
Std.
Std.
Opt.
Std.
N/A
Std.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Std.
Std.
Opt.
Opt.
Opt.
N/A
Std.
Std.
N/A
Opt.
Std.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
N/A
Opt.
N/A
Opt.
Opt.
Std.
Std.
Std.
Std.
Opt.
Opt.
Opt.
N/A
Std.
Std.
Opt.
Opt.
Std.
Std.
N/A
Opt.
Opt.
N/A
N/A
Opt.
N/A
Opt.
N/A
N/A
Std.
N/A
Std.
N/A
Std.
N/A
Std.
Opt.
Std.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
Opt.
Opt.
Opt.
N/A
MotorType
PSC
ECM
PSC Motor Sizes
115 volt
277 volt
208 volt
347 volt
Horse Power
1/13
1/10
1/8
1/6
1/4
1/3
1/2
3/4
1
PSC Cfm Range @ .25 DSP
N/A
N/A
Opt.
N/A
N/A
N/A
N/A
N/A
Opt.
N/A
Opt.
N/A
N/A
N/A
N/A
N/A
Opt.
Opt.
N/A
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
N/A
N/A
210–2500 cfm 200–2650 cfm 215–2400 cfm 220–2900 cfm 150–2185 cfm
Motor Speeds
Variable Speed (SCR)
Multi Speed
Std.
N/A
Std.
N/A
N/A
Std.
Std.
N/A
Std.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
D/S
N/A
N/A
Opt.
Opt.
Controls
Direct Digital Controls
Analog Controls
Pneumatic Controls
Other Options
Attenuators
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
14
Parallel
Fan-Powered
Primary
Inlet Airflow
Ranges (Cfm)
Trane
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
6
8
10
12
14
16
0–500
0–900
0–1400
0–2000
0–3000
0–4000
60–500
110–900
165–1400
235–2000
320–3000
420–4000
120–500
210–900
328–1400
470–2000
640–3000
840–4000
80–500
140–900
220–1400
320–2000
425–3000
560–4000
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
6
8
10
12
14
16
0–500
0–900
0–1400
0–2000
0–3000
0–4000
80–500
145–900
230–1400
325–2000
450–3000
580–4000
80–500
145–900
230–1400
325–2000
450–3000
580–4000
150–500
265–900
415–1400
600–2000
810–3000
1100–4000
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
4
5
6
8
10
12
14
16
0–250
0–350
0–550
0–1000
0–1600
0–2300
0–3100
0–4100
30–250
50–350
55–530
105–1000
165–1355
240–2300
335–3100
440–4100
35–250
50–350
60–550
115–1000
185–1600
285–2300
390–3100
520–4100
45–250
65–350
75–490
145–960
235–1545
340–2250
475–3100
625–4100
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
6
8
10
12
14
16
0–450
0–800
0–1350
0–2100
0–3000
0–4000
66–450
132–800
221–1350
304–2100
439–3000
568–4000
66–450
132–800
221–1350
304–2100
439–3000
568–4000
66–450
132–800
221–1350
304–2100
439–3000
568–4000
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
6
8
10
12
14
16
0–500
0–1000
0–1435
0–2185
0–2745
0–3730
70–500
150–1000
205–1435
260–2185
380–2745
480–3730
70–500
150–1000
205–1435
260–2185
380–2745
480–3730
85–500
180–1000
250–1435
320–2185
470–2745
590–3730
Titus
ETI
Price
Nailor
VAV-SLM005-EN
15
Parallel
Fan-Powered
Valve/Fan
Combinations
Trane VP*F
Fan Size
01
02
03
04
05
06
07
4"
5"
(210–500 cfm)
(300–615 cfm)
(500–925 cfm)
(575–1150 cfm)
(1000–1675 cfm)
(1000–2350 cfm)
(1300–2500 cfm)
6"
X
X
Inlet Sizes
8"
10"
X
X
X
X
12"
14"
16"
Total
19
X
X
X
X
X
X
X
X
X
X
X
X
X
14"
16"
Titus TQP
Fan Size
2
3
4
5
6
4"
5"
(200–600 cfm)
(410–1270 cfm)
(840–1500 cfm)
(700–1700 cfm)
(1340–2650 cfm)
6"
X
X
Inlet Sizes
8"
10"
X
X
X
X
X
X
X
12"
X
X
X
X
X
X
X
X
X
X
12"
14"
16"
Total
19
ETI VFR
Fan Size
4"
5"
6"
4 (215–420 cfm)
6 (480–595 cfm)
11 (690–1150 cfm)
18 (1450–1890 cfm)
21 (1600–2075 cfm)
24 (1800–2400 cfm)
X
X
X
X
Inlet Sizes
8"
10"
X
X
X
Total
19
X
X
X
X
X
X
X
X
X
X
X
X
12"
14"
16"
Price F*V
Fan Size
20
30
40
50
60
4"
5"
(220–670 cfm)
(500–1250 cfm)
(780–1910 cfm)
(1490–2450 cfm)
(2000–2900 cfm)
6"
X
Inlet Sizes
8"
10"
X
X
X
X
X
Total
14
X
X
X
X
X
X
X
X
14"
16"
Nailor 35P
Fan Size
2
3
4
5
6
7
VAV-SLM005-EN
4"
5"
(150–540 cfm)
(150–775 cfm)
(650–1080 cfm)
(590–1400 cfm)
(860–1670 cfm)
(1050–2185 cfm)
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
6"
X
X
Inlet Sizes
8"
10"
X
X
X
X
X
X
X
X
X
X
12"
Total
22
X
X
X
X
X
X
X
X
X
X
16
Parallel
Fan-Powered
Performance
Data—Size
Comparison
Trane VPxF—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
01
02
03
04
05
06
07
30
30
30
30
30
40
40
36
36
36
36
36
46
46
36.75
36.75
36.75
36.75
36.75
46.75
46.75
40
40
40
40
40
40
40
15.5
15.5
15.5
21.5
21.5
21.5
21.5
8.33
8.33
8.33
8.33
8.33
11.11
11.11
10.76
10.76
10.76
14.93
14.93
19.91
19.91
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.75
6.75
6.75
6.75
6.75
6.75
6.75
Titus TQP—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
2
3
4
5
6
40.875
40.875
40.875
46.875
46.875
50.625
50.625
50.625
56.625
56.625
49.875
49.875
49.875
55.875
55.875
36.25
36.25
36.25
48.25
48.25
17.125
17.125
17.125
20.125
20.125
10.29
10.29
10.29
15.71
15.71
14.68
14.68
14.68
26.34
26.34
9.75
9.75
9.75
9.75
9.75
9.00
9.00
9.00
9.00
9.00
ETI VFR—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
4
6
11
18
21
24
23.5
23.5
29.5
29.5
29.5
29.5
31.5
31.5
37.5
37.5
37.5
37.5
28.5
28.5
34.5
34.5
34.5
34.5
29
29
37
37
45
49
14
14
17
17
19
19
4.73
4.73
7.58
7.58
9.22
10.04
5.52
5.52
10.74
10.74
14.60
15.89
8.00
8.00
8.00
8.00
8.00
8.00
5.00
5.00
5.00
5.00
5.00
5.00
Price FDV—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
20
30
40
50
60
22.75
24
29.5
35
36.25
28.75
33
38.5
44
45.25
27.75
29
34.5
40
41.25
28.75
33.5
38.5
42.5
42.5
14
17.5
17.5
20
20
4.54
5.58
7.89
10.33
10.70
5.30
8.14
11.50
17.22
17.83
6.00
9.00
9.00
9.00
9.00
5.00
5.00
5.00
5.00
5.00
Nailor 35P—Size Comparison
VAV-SLM005-EN
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
2
3
4
5
6
7
36
46
46
46
48
48
48.5
61.25
61.25
61.25
63.25
63.25
36
46
46
46
48
48
34
40
40
40
50
50
14
17
17
17
19
19
8.50
12.78
12.78
12.78
16.67
16.67
9.92
18.10
18.10
18.10
26.39
26.39
12.50
15.25
15.25
15.25
15.25
15.25
0.00
0.00
0.00
0.00
0.00
0.00
17
Parallel
Fan-Powered
Performance
Data—Fan Airflow
Comparison
Trane Fan Performance @ .25" DSP
Cooling
Only
HW
1-row
HW
2-row
Cfm
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
Size 7
Max.
Min.
Max.
Min.
Max.
Min.
500
210
475
210
475
210
615
300
580
300
565
300
925
500
905
500
890
500
1150
575
1110
575
1080
575
1677
675
1534
675
1488
675
2350
1000
2100
1000
1900
1000
2500
1300
2150
1300
1900
1300
Size 5
Size 6
Size 7
8.5%
11.3%
10.6%
19.1%
14.0%
24.0%
% Reduction from Cooling Only Max.
Size 1 Size 2 Size 3 Size 4
1-row
2-row
5.0%
5.0%
5.7%
8.1%
2.2%
3.8%
3.5%
6.1%
Titus Fan Performance @ .25" DSP
Cooling
Only
HW
1-row
HW
2-row
Cfm
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
Size 7
Max.
Min.
Max.
Min.
Max.
Min.
—
—
—
—
—
—
600
200
560
200
550
200
1275
410
1150
410
1050
410
1480
830
1275
830
1150
830
1700
650
1600
650
1500
650
2630
1330
2350
1330
2175
1330
—
—
—
—
—
—
Size 5
Size 6
Size 7
5.9%
11.8%
10.6%
17.3%
0.0%
0.0%
% Reduction from Cooling Only Max.
Size 1 Size 2 Size 3 Size 4
1-row
2-row
0.0%
0.0%
6.7%
8.3%
9.8%
17.6%
13.9%
22.3%
ETI Fan Performance @ .25" DSP
Cfm
Cooling
Only
HW
1-row
HW
2-row
Max.
Min.
Max.
Min.
Max.
Min.
Size 04 Size 06 Size 11 Size 18 Size 21 Size 24 Size 30 Size 40 Size 44
410
215
400
215
390
215
595
200
580
200
570
200
1120
100
1090
100
1080
100
1900
800
1850
800
1800
800
2010
1000
1950
1000
1850
1000
2390
1200
2300
1200
2150
1200
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
% Reduction from Cooling Only Max.
Size 04 Size 06 Size 11 Size 18 Size 21 Size 24 Size 30 Size 40 Size 44
1-row
2-row
2.4%
4.9%
2.5%
4.2%
2.7%
3.6%
2.6%
5.3%
3.0%
8.0%
3.8%
10.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
Price Fan Performance @ .25" DSP
Cfm
Cooling
Only
HW
1-row
HW
2-row
Max.
Min.
Max.
Min.
Max.
Min.
Size 10 Size 20 Size 30 Size 40 Size 50 Size 60
—
—
—
—
—
—
675
225
580
225
540
225
1250
500
1100
500
975
500
1900
790
1750
790
1500
790
2450
1490
2150
1490
2000
1490
2900
2000
2750
2000
2525
2000
% Reduction from Cooling Only Max.
Size 10 Size 20 Size 30 Size 40 Size 50 Size 60
1-row
2-row
0.0%
0.0%
14.1%
20.0%
12.0%
22.0%
7.9%
21.1%
12.2%
18.4%
5.2%
12.9%
Nailor Fan Performance @ .25" DSP
Cooling
Only
HW
1-row
HW
2-row
Cfm
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
Size 7
Max.
Min.
Max.
Min.
Max.
Min.
—
—
—
—
—
—
575
150
540
90
540
90
830
150
775
150
775
150
1150
640
1090
640
1090
640
1510
590
1400
590
1400
590
1670
870
1670
870
1670
870
2185
1050
1600
1050
1600
1050
Size 5
Size 6
Size 7
7.3%
7.3%
0.0%
0.0%
26.8%
26.8%
% Reduction from Cooling Only Max.
Size 1 Size 2 Size 3 Size 4
1-row
2-row
VAV-SLM005-EN
0.0%
0.0%
6.1%
6.1%
6.6%
6.6%
5.2%
5.2%
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
18
Parallel
Fan-Powered
Performance
Data—Fan Airflow
Comparison
Parallel Fan Airflow Comparison
07
06
05
04
Trane
03
02
01
6
5
4
Fan Size
2
Titus
3
24
21
18
ETI
11
06
04
60
50
40
Price
30
20
7
6
5
0
Nailor
4
3
2
500
1000
1500
2000
2500
3000
Cfm Range
VAV-SLM005-EN
19
Parallel
Fan-Powered
Performance
Data—Fan Airflow
Comparison
Parallel Fan Airflow Comparison w/ 1-Row HW
07
06
05
04
Trane
03
02
01
6
5
4
3
Titus
Fan Size
2
24
21
18
11
ETI
06
04
60
50
40
Price
30
20
7
6
5
0
Nailor
4
3
2
500
1000
1500
2000
2500
3000
Cfm Range
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
20
Parallel
Fan-Powered
Performance
Data—Fan Airflow
Comparison
Fan Airflow Comparison w/ 2-row HW
07
06
05
04
Trane
03
02
01
6
5
4
Titus
3
2
24
Fan Size
21
18
ETI
11
06
04
60
50
40
Price
30
20
7
6
5
Nailor
4
3
2
0
500
1000
1500
2000
2500
3000
Cfm Range
VAV-SLM005-EN
21
Parallel
Fan-Powered
Trane Air Pressure Drop—in. wg (I-P)
Inlet/Fan Airflow Cooling
Size
Cfm
Only
06–01
08–01
06–02
08–02
10–02
08–03
10–03
12–03
08–04
10–04
210
300
400
500
210
300
400
500
300
375
450
500
300
400
500
600
300
400
500
615
500
625
750
900
500
725
850
925
500
725
850
925
575
700
800
900
575
700
900
1150
0.06
0.12
0.22
0.35
0.01
0.02
0.04
0.06
0.12
0.19
0.28
0.35
0.02
0.04
0.06
0.09
0.01
0.01
0.01
0.01
0.08
0.12
0.17
0.24
0.01
0.02
0.03
0.04
0.01
0.01
0.01
0.01
0.10
0.15
0.19
0.24
0.01
0.02
0.04
0.06
Titus Air Pressure Drop—in. wg (I-P)
Inlet/Fan Airflow Cooling
Size
Cfm
Only
12–04
10–05
12–05
14–05
12–06
14–06
16–06
14–07
16–07
575
700
900
1150
1000
1150
1250
1400
1000
1200
1400
1675
1000
1200
1400
1675
1000
1300
1600
2000
1500
1800
2100
2300
1500
1800
2100
2300
1500
1900
2200
2500
1500
2000
2500
3000
0.01
0.01
0.01
0.01
0.05
0.06
0.07
0.09
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
Inlet/Fan
Size
Airflow
Cfm
TQP
Cooling
06/02
200
300
400
500
200
300
400
500
200
300
400
500
300
375
450
500
300
375
450
500
300
375
450
500
500
625
750
900
750
900
1000
1150
750
900
1000
1150
1000
1150
1300
1400
1100
1300
1400
1700
1100
1300
1400
1700
1100
1300
1400
1700
1500
1600
1800
2000
1800
2100
2400
2600
1800
2100
2400
2600
0.08
0.18
0.32
0.5
0.019
0.043
0.08
0.13
0.01
0.019
0.035
0.055
0.18
0.26
0.4
0.5
0.043
0.065
0.1
0.13
0.019
0.03
0.045
0.055
0.13
0.19
0.28
0.39
0.125
0.175
0.21
0.25
0.065
0.1
0.12
0.13
0.19
0.24
0.32
0.36
0.13
0.18
0.2
0.29
0.065
0.09
0.095
0.15
0.044
0.63
0.069
0.11
0.2
0.225
0.32
0.4
0.175
1.8
0.31
0.37
0.13
0.17
0.225
0.26
08/02
10/02
06/03
08/03
10/03
08/04
10/04
12/04
10/05
12/05
Air Pressure Drop – in. wg (I-P)
Fan
Size
Airflow
Cfm
01–02
1-Row HW
Coil Only
14/05
2-Row HW
Coil Only
210
0.01
.02
300
0.02
.03
400
0.02
.04
500
0.03
.06
600
0.04
.08
03–07
500
0.02
.03
900
0.04
.09
1300
0.08
.15
1700
0.13
.24
2100
0.19
.34
2500
0.26
.45
Note: HW Coil Only pressure drops are just the heating coil.
Electric
Coil Only
.01
.01
.01
.01
.01
.01
.01
.01
.02
.04
.07
16/05
12/06
14/06
16/06
VAV-SLM005-EN
Performance
Data—Pressure
Requirements
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
TQP
1-row coil 2-row coil
0.01
0.01
0.02
0.03
0.01
0.01
0.02
0.03
0.01
0.01
0.02
0.03
0.01
0.01
0.02
0.05
0.01
0.01
0.02
0.03
0.01
0.01
0.02
0.03
0.03
0.04
0.05
0.08
0.05
0.08
0.1
0.12
0.05
0.08
0.1
0.12
0.03
0.04
0.06
0.07
0.04
0.06
0.07
0.09
0.04
0.06
0.07
0.09
0.04
0.06
0.07
0.09
0.07
0.08
0.1
0.12
0.1
0.12
0.16
0.17
0.1
0.12
0.16
0.1
0.01
0.02
0.04
0.05
0.01
0.02
0.04
0.05
0.01
0.02
0.04
0.05
0.02
0.03
0.04
0.05
0.02
0.03
0.04
0.05
0.02
0.03
0.04
0.05
0.05
0.08
0.1
0.15
0.1
0.15
0.18
0.23
0.1
0.15
0.18
0.23
0.07
0.08
0.1
0.12
0.08
0.1
0.12
—
0.08
0.1
0.12
—
0.08
0.1
0.12
—
0.13
0.15
0.18
0.22
0.18
0.23
—
—
0.18
0.23
—
—
Electric
Heat
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
22
Parallel
Fan-Powered
ETI Air Pressure Drop—in. wg (I-P)
Inlet/Fan Airflow
Size
Cfm
0404
0504
0604/
0606
0804/
0806/
0811
1006/
1011/
1018
1211/
1218/
1221/
1411/
1418/
1421/
1524
1621/
1624
100
150
200
250
100
200
300
350
250
300
350
450
550
400
500
600
800
1000
800
1000
1200
1400
1600
1100
1400
1700
2000
2300
1500
1900
2300
2700
3100
2100
2600
3100
3600
4100
VFR
Cooling
0.01
0.01
0.02
0.02
0.01
0.01
0.02
0.02
0.04
0.06
0.08
0.14
0.21
0.03
0.04
0.06
0.1
0.15
0.01
0.01
0.02
0.02
0.03
0.02
0.04
0.06
0.08
0.1
0.04
0.06
0.08
0.12
0.15
0.02
0.03
0.04
0.05
0.07
VFR-WC
1-row coil 2-row coil
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.015
0.01
0.01
0.015
0.02
0.025
0.02
0.02
0.03
0.06
—
0.03
0.04
0.05
0.07
0.09
0.045
0.07
0.1
—
—
0.06
0.095
—
—
—
0.1
—
—
—
—
0.01
0.01
0.01
0.01
0.01
0.01
0.02
0.025
0.015
0.02
0.025
0.04
0.06
0.03
0.05
0.07
0.11
—
0.05
0.08
0.11
0.14
0.18
0.09
0.14
0.205
—
—
0.125
0.19
—
—
—
0.23
—
—
—
—
Price Air Pressure Drop—in. wg (I-P)
VFR-EH
Elec. Heat
0.01
0.01
0.02
0.03
0.01
0.02
0.05
0.0
0.03
0.05
0.07
0.11
0.17
0.04
0.06
0.09
0.16
0.25
0.03
0.04
0.06
0.08
0.11
0.03
0.05
0.07
0.11
0.14
0.02
0.03
0.04
0.05
0.07
0.02
0.03
0.05
0.06
0.08
Inlet/Fan Airflow
Size
Cfm
2006
2008
2010
3008
3010
3012
4010
4012
4014
5012
5014
5016
6014
6016
VAV-SLM005-EN
Performance
Data—Pressure
Requirements
250
350
450
400
600
800
750
1050
1350
400
600
800
750
1050
1350
900
1300
1700
2100
750
1050
1350
900
1300
1700
2100
1500
2000
2500
3000
900
1300
1700
2100
1500
2000
2500
3000
2500
3000
3500
4000
1500
2000
2500
3000
2500
3000
3500
4000
FxV
Cooling
0.07
0.13
0.22
0.01
0.03
0.06
0.01
0.02
0.05
0.03
0.05
0.07
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
FxV
1-row coil 2-row coil
0.04
0.07
0.11
0.09
0.175
—
—
—
—
—
0.09
0.15
0.135
—
—
0.18
—
—
—
—
0.135
0.21
0.1
0.19
—
—
0.25
—
—
—
—
—
0.16
0.23
0.13
0.21
—
—
—
—
—
—
—
0.16
0.23
—
0.23
—
—
—
0.08
0.14
0.21
0.17
0.345
—
—
—
—
—
0.18
0.29
0.26
—
—
0.35
—
—
—
—
0.27
0.42
0.21
0.39
—
—
0.5
—
—
—
—
—
0.32
0.46
0.26
0.43
—
—
—
—
—
—
—
0.37
0.46
—
0.46
—
—
—
FxV
Elec. Heat
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
23
Parallel
Fan-Powered
Performance
Data—Pressure
Requirements
Nailor Air Pressure Drop—in. wg (I-P)
Inlet/Fan Airflow
Size
Cfm
06/02
08/02
10/02
10/03
12/03
14/03
16/03
10/04
12/04
14/04
200
300
400
500
175
350
525
875
275
550
825
1100
275
550
825
1100
400
800
1200
1600
525
1050
1575
2100
700
1400
2100
2800
275
550
825
1100
400
800
1200
1600
525
1050
1575
2100
VAV-SLM005-EN
35P
Cooling
0.05
0.05
0.05
0.12
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.08
0.14
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
35P
1-row coil 2-row coil
0.01
0.019
0.03
0.045
0.01
0.025
0.048
—
0.016
—
—
—
0.01
0.035
—
—
0.02
—
—
—
0.033
—
—
—
0.52
—
—
—
0.01
0.035
0.08
—
0.02
0.07
—
—
0.033
0.15
—
—
0.02
0.04
0.065
0.095
0.016
0.052
0.11
—
0.035
—
—
—
0.027
0.085
—
—
0.05
—
—
—
0.08
—
—
—
0.14
—
—
—
0.027
0.12
0.18
—
0.05
0.18
—
—
0.11
0.25
—
—
35P
Elec. Heat
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Inlet/Fan Airflow
Size
Cfm
16/04
10/05
12/05
14/05
16/05
14/06
16/06
14/07
16/07
700
1400
2100
2800
275
550
825
1100
400
800
1200
1600
525
1050
1575
2100
700
1400
2100
2800
525
1050
1575
2100
700
1400
2100
2800
525
1050
1575
2100
700
1400
2100
2800
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
35P
Cooling
0.05
0.05
0.08
0.14
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.08
0.14
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.06
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.06
35P
1-row coil 2-row coil
0.52
—
—
—
0.01
0.018
0.036
0.055
0.012
0.035
0.057
—
0.017
0.054
—
—
0.29
0.09
—
—
0.01
0.034
0.058
—
0.017
0.052
—
—
0.01
0.034
0.058
—
0.017
0.052
—
—
0.14
—
—
—
0.014
0.045
0.08
0.14
0.026
0.08
0.14
—
0.043
0.11
—
—
0.065
0.2
—
—
0.023
0.075
0.15
—
0.038
0.13
—
—
0.023
0.075
0.15
—
0.038
0.13
—
—
35P
Elec. Heat
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
24
Parallel
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Trane—Fan Size 01,02 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
215
250
300
350
0.5
1.0
2.0
3.0
4.0
5.0
1.0
2.0
3.0
4.0
5.0
0.22
0.77
2.67
5.57
9.43
14.22
1.33
4.47
9.15
15.29
22.79
10.78
13.17
14.66
15.24
15.54
15.73
16.03
17.34
17.80
18.03
18.17
11.44
14.14
15.89
16.58
16.94
17.17
18.44
20.24
20.87
21.19
21.39
12.24
15.31
17.43
18.26
18.71
19.00
21.36
23.94
24.84
25.31
25.59
12.87
16.32
18.77
19.74
20.28
20.61
23.77
27.17
28.39
29.01
29.39
13.39
17.18
19.95
21.06
21.67
22.06
25.79
30.02
31.56
32.35
32.84
1-Row
Capacity
MBH
2-Row
Capacity
MBH
Airflow (Cfm)
400
450
13.82
17.94
21.00
22.25
22.94
23.37
27.48
32.53
34.42
35.39
35.99
500
550
590
14.19
18.67
21.96
23.34
24.09
24.57
28.92
34.77
37.00
38.16
38.87
14.50
19.32
22.83
24.33
25.16
25.68
—
36.78
39.34
40.69
41.52
14.73
19.79
23.47
25.07
25.95
26.51
—
38.23
41.07
42.57
43.50
Trane—Fan Size 03-07 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
500
700
900
1100
Airflow (Cfm)
1300
1500
1700
1900
2100
2300
1.0
2.0
3.0
4.0
5.0
6.0
7.0
2.0
3.0
4.0
5.0
6.0
7.0
0.37
1.25
2.59
4.35
6.52
9.07
12.03
2.25
4.59
7.63
11.33
15.67
20.66
21.41
25.94
27.88
28.95
29.64
30.12
30.47
36.46
38.88
40.13
40.90
41.42
41.80
24.01
29.73
32.36
33.84
34.80
35.48
35.97
44.95
49.06
51.27
52.64
53.57
54.25
25.79
32.60
35.83
37.68
38.89
39.74
40.37
50.87
56.61
59.78
61.77
63.14
64.14
27.10
35.00
38.62
40.81
42.24
43.25
44.00
55.20
62.40
66.46
69.06
70.87
72.19
28.12
36.95
40.96
43.44
45.07
46.23
47.10
58.55
67.02
71.92
75.09
77.31
78.95
29.62
39.95
44.81
47.68
49.68
51.11
52.18
—
74.17
80.55
84.77
87.76
89.98
—
41.16
46.39
49.47
51.60
53.15
54.32
—
77.08
84.13
88.83
92.18
94.69
—
42.21
47.79
51.10
53.34
55.00
56.25
—
79.69
87.37
92.54
96.24
99.02
—
43.15
49.05
52.57
54.92
56.68
58.01
—
—
—
—
—
—
1-Row
Capacity
MBH
2-Row
Capacity
MBH
28.94
38.57
43.00
45.70
47.52
48.82
49.80
—
70.87
76.54
80.24
82.86
84.79
Notes:
1. Fouling Factor = 0.00025
2. The off-coil temperature of the hot water coil on parallel fan-powered units must not exceed 140°F.
3. The following equations may be used in calculating Leaving Air Temperature (LAT) and Water Temperature Difference (WTD)
4. Capacity based on 70°F entering air temperature and 180°F entering water temperature. Refer to correction factors for different
entering conditions.
(
)
(
LAT = EAT + MBH x 921.7
CFM
WTD = EWT - LWT = 2 x MBH
GPM
)
Temperature Correction Factors for Water Pressure Drop (Ft)
Average Water Temperature
Correction Factor
200
190
180
0.970 0.985 1.000
170
1.020
160
1.030
150
1.050
140
1.080
130
1.100
120
1.130
110
1.150
40
50
60
70
80
90
100
110
0.355 0.446 0.537 0.629 0.722 0.814 0.907 1.000
120
1.093
130
1.187
Temperature Correction Factors for Coil Capacity (MBH)
Entering Water Minus Entering Air
Correction Factor
Coils - Water Weights
Unit
Type
VPWF
VPWF
VPWF
VPWF
VAV-SLM005-EN
Fan
Size
01,02
01,02
03-07
03-07
Coil
Type
1-Row
2-Row
1-Row
2-Row
Internal
Volume
(in.3)
32.52
57.90
51.21
89.27
Internal Operating
Volume Weight
(gal.)
(lbs)
0.141
12.3
0.251
16.8
0.222
14.5
0.386
20.1
25
Parallel
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Titus—Fan Size 2 (I-P)
Rows
Gpm
WPD (ft)
180
230
280
330
1-row
Capacity
MBH
1
2
4
6
1
2
4
6
0.3
0.9
3.2
6.5
0.6
2.0
6.8
13.9
12.3
13.4
14.1
14.3
16.8
18.1
18.8
19.1
13.7
15.1
16
16.3
19.6
21.6
22.7
23.1
14.8
16.5
17.5
17.9
22.0
24.7
26.2
26.7
15.7
17.7
18.9
19.4
24.1
27.4
29.4
30.1
2-row
Capacity
MBH
Airflow (Cfm)
380
430
480
530
580
17.1
19.6
21.1
21.7
27.4
32.2
35.0
36.1
17.7
20.4
22.1
22.7
28.8
34.2
37.6
38.8
18.3
21.1
22.9
23.7
30.0
36.1
40.0
41.4
18.7
21.7
23.7
24.4
31.1
37.9
42.2
43.9
Airflow (Cfm)
840
950
16.5
18.7
20.1
20.6
25.8
29.9
32.3
33.2
Titus—Fan Size 3 (I-P)
Rows
Gpm
WPD (ft)
400
510
620
730
1-row
Capacity
MBH
1
2
4
6
1
2
4
6
0.3
0.9
3.2
6.5
0.6
2.0
6.8
13.9
16.8
19.1
20.5
21.1
26.5
30.8
33.4
34.4
18.1
20.8
22.6
23.3
29.5
35.4
39.0
40.4
19.2
22.4
24.5
25.3
32.0
39.2
43.9
45.7
20.5
24.2
26.7
27.7
33.9
42.5
48.3
50.5
2-row
Capacity
MBH
1060
1170
1280
22.5
27.2
30.5
31.8
36.9
47.9
55.6
58.7
23.4
28.5
32.1
33.6
38.1
50.1
58.8
62.4
24.1
29.7
33.6
35.2
—
—
—
—
24.8
30.7
35.0
36.8
—
—
—
—
Airflow (Cfm)
1080
1150
21.6
25.8
28.7
29.8
35.5
45.4
52.1
54.8
Titus—Fan Size 4 (I-P)
Rows
Gpm
WPD (ft)
800
870
940
1010
1-row
Capacity
MBH
1
2
4
6
1
2
4
6
0.3
0.9
3.2
6.5
0.6
2.0
6.8
13.9
21.2
25.2
28.0
29.1
35.0
44.4
50.8
53.3
21.8
26.2
29.2
30.4
35.9
46.1
53.1
55.9
22.5
27.1
30.3
31.6
36.8
47.6
55.3
58.4
23.0
27.9
31.4
32.8
37.6
49.1
57.4
60.7
2-row
Capacity
MBH
1220
1290
1360
24.0
29.5
33.3
34.9
38.9
51.7
61.2
65.1
24.5
30.2
34.3
35.9
39.5
52.9
63.0
67.1
24.9
30.8
35.1
36.9
—
—
—
—
25.3
31.5
36.0
37.9
—
—
—
—
Airflow (Cfm)
1240
1350
23.5
28.7
32.4
33.9
38.8
50.5
59.4
63.0
Titus—Fan Size 5 (I-P)
Rows
Gpm
WPD (ft)
800
910
1020
1130
1460
1570
1680
1-row
Capacity
MBH
1
2
4
6
1
2
4
5
0.4
1.3
4.3
8.8
0.8
2.6
9.0
13.4
27.6
33.3
37.0
38.4
41.4
53.5
61.3
63.0
28.5
34.7
38.8
40.5
43.1
56.9
66.1
68.1
29.2
35.8
40.3
42.1
44.5
59.9
70.5
72.9
30.3
37.5
42.5
44.5
45.7
62.6
74.5
77.3
32.1
40.5
46.4
48.8
47.7
67.2
81.7
85.2
32.8
41.8
48.2
50.8
48.5
69.1
85.0
88.8
33.6
43.0
49.8
52.7
49.2
70.9
88.0
92.1
34.2
44.1
51.4
54.4
—
—
—
—
1300
1450
1600
Airflow (Cfm)
1750
1900
2050
2200
2350
2500
1
0.4
31.7
2
1.3
39.8
4
4.3
45.5
6
8.8
47.9
2-row
1
0.8
47.3
Capacity
2
2.6
66.2
MBH
4
9.0
80.2
5
13.4
83.5
Note: Water Coil located on plenum inlet.
32.8
41.7
48.0
50.6
48.4
69.0
84.7
88.5
33.7
43.3
50.3
53.2
49.3
71.4
88.8
93.0
34.6
44.8
52.4
55.5
50.1
73.6
92.5
97.2
36.7
48.7
58.8
61.9
—
—
—
—
37.3
49.9
59.6
63.8
—
—
—
—
37.8
50.9
61.2
65.6
—
—
—
—
2-row
Capacity
MBH
31.2
39.0
44.5
46.7
46.8
65.0
78.3
81.4
Titus—Fan Size 6 (I-P)
Rows
1-row
Capacity
MBH
VAV-SLM005-EN
Gpm
WPD (ft)
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
35.4
46.2
54.4
57.8
50.8
75.5
96.0
101.1
36.1
47.5
56.2
59.9
51.4
77.3
99.2
104.8
26
Parallel
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
ETI—Fan Sizes 0404, 0504, 0604, 0804, 0806, 0811 (I-P)
Airflow (Cfm)
500
600
Rows
Gpm
WPD (ft)
200
300
400
1-row
Capacity
MBH
0.5
1
2
3
5
0.5
1
2
3
5
0.4
1.2
4.2
8.8
22.1
0.1
0.3
1.2
2.5
6.2
10.74
12.50
13.60
14.02
—
13.92
—
—
—
—
12.81
15.51
20.89
17.99
18.59
16.60
21.37
—
—
—
14.25
17.81
20.25
21.22
22.07
18.32
24.65
—
—
—
2-row
Capacity
MBH
700
800
16.73
22.44
26.68
28.45
30.05
—
30.86
39.45
43.32
46.97
17.21
23.53
28.33
30.34
32.31
—
32.21
41.92
46.38
50.64
Airflow (Cfm)
1000
1200
1400
1600
1800
20.73
29.84
37.15
40.13
43.21
—
39.05
53.05
59.73
66.22
—
32.92
42.62
46.96
51.03
—
42.21
60.54
69.81
79.14
—
34.01
44.81
49.70
54.32
—
43.18
63.37
73.82
84.49
—
34.88
46.72
52.14
57.30
—
43.86
65.78
77.33
89.29
15.31
19.64
22.71
23.96
25.06
—
27.19
33.3
—
—
16.12
21.16
24.83
26.34
27.69
—
29.21
36.62
39.88
—
ETI—Fan Sizes 1006, 1018, 1211, 1218, 1221 (I-P)
Rows
Gpm
WPD (ft)
400
600
800
1-row
Capacity
MBH
0.5
1
2
3
5
0.5
1
2
3
5
0.5
1.6
5.5
11.3
28.2
0.1
0.5
1.6
3.2
8.0
16.33
20.62
23.56
24.73
25.74
20.24
27.44
—
—
—
18.56
24.72
29.25
31.10
32.75
—
32.90
41.49
—
—
19.91
27.64
33.62
36.14
38.42
—
36.51
47.98
53.24
—
2-row
Capacity
MBH
—
31.55
40.11
43.87
47.36
—
40.88
57.15
65.17
73.11
ETI—Fan Sizes 1411, 1418, 1424, 1621, 1624 (I-P)
Rows
Gpm
WPD (ft)
1000
1200
Airflow (Cfm)
1400
1600
1800
2000
2200
1-row
Capacity
MBH
0.5
1
2
3
5
0.5
1
2
3
5
0.6
1.8
6.3
12.8
31.2
—
0.6
1.8
3.7
9.1
21.69
31.45
39.38
42.81
45.96
—
40.59
55.45
62.55
69.45
—
33.28
42.56
46.66
50.47
—
42.53
59.82
68.38
76.86
—
34.74
45.27
50.01
54.47
—
43.96
63.44
73.36
83.36
—
37.61
51.52
58.02
64.28
—
—
7125
84.78
99.04
—
38.21
53.15
60.20
67.02
—
—
73.15
87.76
103.32
2-row
Capacity
MBH
—
34.01
47.63
52.98
58.05
—
45.00
66.47
77.67
89.15
—
36.85
49.69
55.63
61.31
—
45.75
69.04
81.45
94.34
Notes:
1. Data is based on entering water temperature of 180°F and entering air temperature of 65°F.
2. Water Coil located on plenum inlet.
VAV-SLM005-EN
27
Parallel
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Price—Fan Size 20 (I-P)
Airflow (Cfm)
400
450
Rows
Gpm
WPD (ft)
250
300
350
1-Row
Capacity
MBH
0.5
1.0
2.0
3.0
1.0
2.0
4.0
6.0
.18
.45
1.54
3.17
.45
1.54
5.29
10.88
7.0
8.1
9.1
9.7
13.2
16.1
19.3
21.3
7.5
8.7
9.9
10.5
13.9
17.0
20.4
22.6
8.0
9.3
10.6
11.3
14.6
17.9
21.5
23.8
2-Row
Capacity
MBH
8.5
9.9
11.3
12.0
15.2
18.7
22.5
24.9
9.0
10.5
12.0
12.8
15.8
19.5
23.5
26.0
550
650
9.9
11.6
13.3
14.2
17.0
21.0
25.3
28.1
10.8
12.7
14.5
15.5
18.2
22.5
27.1
30.0
Price—Fan Size 30 (I-P)
Airflow (Cfm)
700
800
Rows
Gpm
WPD (ft)
550
600
650
900
1000
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.5
3.0
6.0
9.0
.22
.82
3.15
6.91
.42
1.43
4.9
10.08
13.2
15.2
17.1
18.1
22.0
27.0
32.4
35.9
13.7
15.8
17.8
18.9
22.6
27.8
33.5
37.0
14.2
16.5
18.5
19.7
23.2
28.6
34.4
38.1
15.8
18.3
20.6
22.0
25.0
30.9
37.2
41.2
16.8
19.5
22.0
23.4
26.2
32.3
39.0
43.2
17.8
20.7
23.4
24.8
27.4
33.8
40.8
45.2
2-Row
Capacity
MBH
14.8
17.1
19.3
20.5
23.8
29.4
35.4
39.1
Price—Fan Size 40 (I-P)
Rows
Gpm
WPD (ft)
800
900
Airflow (Cfm)
1000
1100
1200
1300
1500
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.5
3.0
6.0
9.0
.28
1.09
4.15
9.10
.55
1.88
6.45
13.27
17.0
19.9
22.6
24.1
28.4
35.3
42.8
47.5
17.9
21.0
24.0
25.6
29.5
36.7
44.6
49.6
18.9
22.2
25.3
27.0
30.6
38.1
46.4
51.5
20.7
24.4
27.8
29.8
32.8
40.9
49.8
55.4
21.7
25.5
29.1
31.1
33.9
42.3
51.4
57.2
23.6
27.7
31.6
33.8
36.0
45.0
54.7
60.9
2-Row
Capacity
MBH
19.8
23.3
26.6
28.4
31.7
39.5
48.1
53.5
Price—Fan Size 50 (I-P)
Rows
Gpm
WPD (ft)
1500
1600
Airflow (Cfm)
1700
1800
1900
2000
2100
1-Row
Capacity
MBH
1.5
3.0
6.0
9.0
2.0
4.0
8.0
12.0
.26
.99
3.78
8.28
.56
1.93
6.60
13.58
28.1
33.0
37.6
40.2
44.0
55.0
67.1
74.7
29.1
34.1
38.9
41.5
45.0
56.4
68.8
76.6
30.0
35.2
40.2
42.9
46.1
57.7
70.4
78.4
31.9
37.5
42.7
45.7
48.2
60.4
73.7
82.1
32.8
38.6
44.0
47.0
49.3
61.7
75.3
83.9
33.8
39.7
45.3
48.4
50.3
63.0
77.0
85.7
2000
2100
Airflow (Cfm)
2200
2300
2400
2500
2600
1.5
.29
33.7
3.0
1.13
40.0
6.0
4.31
45.9
9.0
9.45
49.2
2-Row
3.0
.43
58.2
Capacity
6.0
1.47
72.3
MBH
12.0
5.02
87.6
18.0
10.33
97.3
Note: Water Coil located on plenum inlet.
34.6
41.0
47.1
50.5
59.4
73.7
89.4
99.2
35.5
42.1
48.3
51.8
60.5
75.1
91.1
101.1
38.2
45.3
52.0
55.7
63.9
79.3
96.2
106.7
39.1
46.4
53.2
57.0
65.0
80.7
97.8
108.6
2-Row
Capacity
MBH
31.0
36.4
41.5
44.3
47.1
59.0
72.1
80.3
Price—Fan Size 60 (I-P)
Rows
1-Row
Capacity
MBH
VAV-SLM005-EN
Gpm
WPD (ft)
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
36.4
43.2
49.6
53.1
61.6
76.5
92.8
103.0
37.3
44.2
50.8
54.4
62.8
77.9
94.5
104.9
28
Parallel
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Nailor—Fan Size 2 (I-P)
Rows
Gpm
WPD (ft)
200
300
Airflow (Cfm)
400
500
1-Row
Capacity
MBH
1
2
4
5
1
2
4
5
1
3.75
10.0+
10.0+
0.28
1
3.6
5.7
9.75
10.5
11.0
11.1
13.9
15.3
16.1
16.5
11.9
13.1
14.0
14.1
17.4
19.9
21.5
22
13.8
15.2
16.2
16.5
19.8
23.5
25.9
26.5
2-Row
Capacity
MBH
600
700
14.9
16.9
18.1
18.5
21.9
26.5
29.4
30.2
15.9
18.3
19.75
20.1
23.5
28.8
32.6
33.5
16.8
19.5
21.2
21.5
24.9
31
35.5
36.4
Nailor—Fan Sizes 3 & 4 (I-P)
Rows
Gpm
WPD (ft)
300
500
Airflow (Cfm)
700
900
1100
1300
1-Row
Capacity
MBH
1
2
4
5
1
2
4
5
1.2
4.5
10.0+
10.0+
0.3
1.2
4.3
6.9
12.8
14.2
15.0
15.2
18.1
20.9
22.1
23.0
16.1
18.3
19.8
20.0
23.0
28.1
31.2
32.2
18.4
21.4
23.2
23.7
30.5
35.2
40.8
39.0
21.3
25.4
28.3
29.0
30.5
40.3
47.8
49.4
22.4
27.0
30.4
31.2
31.8
43.0
51.4
53.4
2-Row
Capacity
MBH
19.9
23.5
26.0
26.6
28.6
37.1
43.4
44.8
Nailor—Fan Size 5 (I-P)
Rows
Gpm
WPD (ft)
600
800
Airflow (Cfm)
1000
1200
1400
1600
1800
1-Row
Capacity
MBH
1
2
4
5
1
2
4
5
0.19
0.75
2.8
4.3
0.16
0.58
2.3
3.4
19.1
22.8
25.1
25.7
27.0
32.0
38.0
40.0
21.4
25.9
29.0
29.7
30.4
35.4
46.0
47.8
22.8
28.4
32.1
33.0
32.2
43.0
51.6
53.9
25.2
32.0
37.0
38.1
35.1
49.2
60.9
63.5
26.2
33.5
39.0
40.5
36.2
51.5
62.0
67.9
26.8
34.8
41.0
42.4
37.2
53.8
67.8
71.5
Airflow (Cfm)
1400
1600
1800
2000
2200
28.8
36.8
42.9
44.4
38.2
55.0
71.9
79.4
31.2
41.5
49.5
51.8
41.3
61.3
82.4
96.2
32.0
42.8
51.5
53.8
42.2
63.0
88.1
101.3
2-Row
Capacity
MBH
24.1
30.3
34.6
35.7
34.0
46.5
56.6
59.1
Nailor—Fan Sizes 6 & 7 (I-P)
Rows
1-Row
Capacity
MBH
Gpm
WPD (ft)
1000
1200
1
0.27
25.9
26.7
2
0.97
32.2
33.9
4
3.6
37.0
39.0
8
5.5
37.9
39.6
2-Row
1
0.19
35.3
37.0
Capacity
2
0.7
37.6
53.4
MBH
5
2.8
59.8
66.4
10
4.0
65.0
73.0
Note: Water Coil located internally on parallel unit.
VAV-SLM005-EN
29.6
38.6
45.4
47.0
39.8
57.8
76.3
86.3
30.5
40.0
47.5
49.3
41.9
59.8
80.6
91.3
29
Parallel
Fan-Powered
Performance
Data—
Electric Coil
VPEF Trane Electrical Coil kW Guidelines—Minimum to Maximum
Fan
Size
01
(210–500 cfm)
02
(300–615 cfm)
03
(500–925) cfm)
04
(575–1150cfm)
05
(1000–1675 cfm)
06
(1000–2350 cfm)
07
(1300–2500 cfm)
Stages
208V/240V
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
0.5–4.0
0.5–4.0
1.0–4.0
0.5–6.0
0.5–6.0
1.0–6.0
0.5–8.0
0.5–8.0
1.0–8.0
0.5–8.0
0.5–8.0
1.0–8.0
0.5–8.0
0.5–8.0
1.0–8.0
0.5–8.0
0.5–8.0
1.0–8.0
0.5–8.0
0.5–8.0
1.0–8.0
Single–Phase Voltage
277V
347V
0.5–4.0
1.0–4.0
1.0–4.0
0.5–6.0
1.0–6.0
1.0–6.0
0.5–8.0
1.0–8.0
1.0–8.0
0.5–9.0
1.0–9.0
1.0–9.0
0.5–12.0
1.0–12.0
1.0–12.0
0.5–12.0
1.0–12.0
1.0–12.0
0.5–11.0
1.0–11.0
1.0–11.0
0.5–4.0
1.0–4.0
1.5–4.0
0.5–6.0
1.0–6.0
1.5–6.0
0.5–8.0
1.0–8.0
1.5–8.0
0.5–9.0
1.0–9.0
1.5–9.0
0.5–12.0
1.0–12.0
1.5–12.0
0.5–15.0
1.0–15.0
1.5–15.0
0.5–15.0
1.0–15.0
1.5–15.0
Three–Phase Voltage
208V
480V
575V
480V
0.5–4.0
1.0–4.0
1.0–4.0
0.5–6.0
1.0–6.0
1.0–6.0
0.5–8.0
1.0–8.0
1.0–8.0
0.5–9.0
1.0–9.0
1.0–9.0
0.5–12.0
1.0–12.0
1.0–12.0
0.5–16.0
1.0–16.0
1.0–16.0
0.5–20.0
1.0–20.0
1.0–20.0
1.0–4.0
1.0–4.0
1.5–4.0
1.0–6.0
1.0–6.0
1.5–6.0
1.0–8.0
1.0–8.0
1.5–8.0
1.0–9.0
1.0–9.0
1.5–9.0
1.0–14.0
1.0–14.0
1.5–14.0
1.0–15.0
1.0–15.0
1.5–15.0
1.0–14.0
1.0–14.0
1.5–14.0
1.0–4.0
2.0–4.0
3.0–4.0
1.0–6.0
2.0–6.0
3.0–6.0
1.0–8.0
2.0–8.0
3.0–8.0
1.0–9.0
2.0–9.0
3.0–9.0
1.0–12.0
2.0–12.0
3.0–12.0
1.0–16.0
2.0–16.0
3.0–16.0
1.0–20.0
2.0–20.0
3.0–20.0
1.5–4.0
3.0–4.0
—
1.5–6.0
3.0–6.0
4.5–6.0
1.5–8.0
3.0–8.0
4.5–8.0
1.5–9.0
3.0–9.0
4.5–9.0
1.5–12.0
3.0–12.0
4.5–12.0
1.5–16.0
3.0–16.0
4.5–16.0
1.5–20.0
3.0–20.0
4.5–20.0
Fan Electrical Performance
Fan Size
HP
120V
Maximum FLA
208V
277V
01
1/8
1.6
—
02
1/8
1.6
—
03
1/3
5.4
—
04
1/3
5.4
—
05
1/2
7.6
—
06
1/2
—
6.3
07
1
—
6.9
(Note: Same motors as series units.)
0.7
0.7
1.8
1.8
2.6
3.8
4.7
347V
0.7
0.7
1.5
1.5
2.1
3.8
3.6
TQP Titus Electric Coil kW Guidelines—Minimum to Maximum
Fan
Size
2
(200–600 cfm)
3
(410–1270 cfm)
4
(840–1500 cfm)
5
(700–1700 cfm)
6
(1340–2650 cfm)
Stages
208V/240V
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
0.5–7.0
1.0–7.0
1.5–7.0
0.5–8.0
1.0–8.0
1.5–8.0
0.5–8.0
1.0–8.0
1.5–8.0
0.5–8.0
1.0–8.0
1.5–8.0
0.5–8.0
1.0–8.0
1.5–8.0
Single-Phase Voltage
277V
347V
0.5–7.0
1.0–7.0
1.5–7.0
0.5–11.5
1.0–11.5
1.5–11.5
0.5–11.5
1.0–11.5
1.5–11.5
0.5–11.5
1.0–11.5
1.5–11.5
0.5–11.5
1.0–11.5
1.5–11.5
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
480V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
575V
1.5–6.5
1.5–6.5
1.5–6.5
1.5–13.0
1.5–13.0
1.5–13.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–8.5
1.5–8.5
1.5–8.5
1.5–14.0
1.5–14.0
1.5–14.0
1.5–16.0
1.5–16.0
1.5–16.0
1.5–19.0
1.5–19.0
1.5–19.0
1.5–26.0
1.5–26.0
1.5–26.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Fan Electrical Performance
Fan Size
HP
120V
Maximum FLA
208/240V
277V
2
1/6
3.6
1.5
3
1/4
5.3
2.6
4
1/3
7.8
3.2
5
1/3
9.2
3.3
6
3/4
12.3
6.3
(Note: DIFFERENT motors than series units.)
VAV-SLM005-EN
1.3
2.2
2.9
3.2
5.4
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
30
Parallel
Fan-Powered
Performance
Data—
Electric Coil
VFR ETI Electric Coil kW Guidelines—Minimum to Maximum
Fan
Size
4
(215–420 cfm)
6
(480–595 cfm)
11
(690–1150 cfm)
18
(1450–1890 cfm)
21
(1600–2075 cfm)
24
(1800–2400 cfm)
Stages
208V/240V
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
6.0
6.0
6.0
8.5
8.5
8.5
16
16
16
27
27
27
29
29
29
34
34
34
Single-Phase Voltage
277V
347V
6.0
6.0
6.0
8.5
8.5
8.5
16
16
16
27
27
27
29
29
29
34
34
34
6.0
6.0
6.0
8.5
8.5
8.5
16
16
16
27
27
27
29
29
29
34
34
34
480V
6.0
6.0
6.0
8.5
8.5
8.5
16
16
16
27
27
27
29
29
29
34
34
34
Three-Phase Voltage
208V
480V
575V
6.0
6.0
6.0
8.5
8.5
8.5
16
16
16
27
27
27
29
29
29
34
34
34
6.0
6.0
6.0
8.5
8.5
8.5
16
16
16
27
27
27
29
29
29
34
34
34
6.0
6.0
6.0
8.5
8.5
8.5
16
16
16
27
27
27
29
29
29
34
34
34
Notes:
1. Maximum kW determined by dividing the actual fan capacity (cfm) by 70 (i.e. maximum 70 cfm per kW= 45° rise)
2. Cfms are at 0.25" w.c.
Fan Electrical Performance
Fan Size
Max FLA
120V
277V
HP
04
1/13
1.1
0.5
06
1/6
2.6
0.9
11
1/4
4.9
1.9
18
1/2
8.8
3.6
21
3/4
9.7
3.8
24
1
12.3
4.5
(Note: Same motors as series units.)
FEV Price Electric Coil kW Guidelines—Minimum to Maximum
Fan
Size
20
(220–670 cfm)
30
(500–1250 cfm)
40
(780–1910 cfm)
50
(1490–2450 cfm)
60
(2000–2900 cfm)
Stages
208V/240V
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
9.0/10
9.0/10
9.0/10
8.5/10
8.5/10
8.5/10
7.5/8.5
7.5/8.5
7.5/8.5
7.0/8.5
7.0/8.5
7.0/8.5
7.0/9.5
7.0/9.5
7.0/9.5
Single-Phase Voltage
277V
347V
10
10
10
12.5
12.5
12.5
12.2
12.2
12.2
11.5
11.5
11.5
11
11
11
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
480V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
600V
10
10
10
14.5
14.5
14.5
13
13
13
12.5
12.5
12.5
12.5
12.5
12.5
10
10
10
17
17
17
28.5
28.5
28.5
34
34
34
33
33
33
10
10
10
17
17
17
28.5
28.5
28.5
34
34
34
42.5
42.5
42.5
Notes:
1. Minimum kW: Single-Phase=0.5 kW per stage. Three-Phase=1.5 kW per stage.
2. Minimum airflow requirement of 70 cfm/kW
Fan Electrcial Performance
Fan Size
HP
Max FLA
120V
277V
20
1/8
2.9
1.1
30
1/4
4.7
1.7
40
1/2
9.8
3.2
50
3/4
12.3
4.4
60
1
—
7.8
(Note: DIFFERENT motors than series units.)
VAV-SLM005-EN
31
Parallel
Fan-Powered
Performance
Data—
Electric Coil
35PE Nailor Electric Coil kW Guidelines—Minimum to Maximum
Fan
Size
Stages
2
(150–540 cfm)
3
(150–775 cfm)
4
(650–1080 cfm)
5
(590–1400 cfm)
6
(860–1670 cfm)
7
(1050–2185 cfm)
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
Single-Phase Voltage
208V/240V
277V
347V
0.5–7.0
0.5–7.0
0.5–7.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
480V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
575V
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
.05–16.0
.05–16.0
.05–16.0
0.5–20.5
0.5–20.5
0.5–20.5
0.5–25.0
0.5–25.0
0.5–25.0
0.5–28.0
0.5–28.0
0.5–28.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Fan Electrical Performance
Fan Size
HP
120V
Max FLA
208V
2
1/6
4.8
1.8
3
1/4
5.8
3.6
4
1/3
6.2
4.1
5
1/2
10.1
6.5
6, 7
3/4
13.4
8.4
Note: DIFFERENT motors than series units.
Information listed is at high speed)
VAV-SLM005-EN
277V
1.5
1.8
2.0
3.3
4.5
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
32
Series
Parallel
Fan-Powered
Product
Features
Trane
VSCF, VSWF, and VSEF
— 7 Fan sizes available, 280 to 3000 cfm (range based on .25 in. wg DSP)
— 20 Valve/Fan Combinations
— Minimum 16 measuring point flow ring
— Metal encapsulated insulation edges standard for IAQ
— Rugged contractor tough unit construction
— Factory-commissioned controls
— UL and ARI listed
— Factory-mounting customer controls availability
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, and various ‘IAQ’
linings
Titus
DTQS, ETQS, and PTQS
— 6 fan sizes available, 320 to 3100 cfm (range based on .25 in. wg DSP)
— 21 valve/fan combinations
— 5-point flow cross sensing device
— Cast position indicator on damper shaft
— SCR fan speed control
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, and various ‘IAQ’
linings
Green
= Trane is advantaged
Yellow
= Trane is equal
Red
= Trane is disadvantaged
Trane vs. Titus
Page
Encapsulated edges ............................................................................................ 37, 43
Factory-commissioned controls .............................................................................. 40
More measuring points on our flow ring ............................................................. 37, 43
ARI certified units ............................................................................................... 39, 43
Air filter .............................................................................................................. 37, 43
Filter frame ......................................................................................................... 37, 43
Fan disconnect ................................................................................................... 37, 43
Hanger brackets ................................................................................................. 37, 43
Unit access .............................................................................................................. 43
Fan Cfm ranges ............................................................................................ 44, 48–51
SCR fan speed control ............................................................................................. 44
80/20 nickel chrome wire .......................................................................................... 44
Dust tight enclosure for electric reheat ..................................................................... 44
kW availability .......................................................................................... 40, 43, 65–66
Analog controls ....................................................................................................... 39
Steam coils .............................................................................................................. 43
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
33
Series
Fan-Powered
Product
Features
Trane
VSCF, VSWF, and VSEF
— 7 Fan sizes available, 280 to 3000 cfm (range based on .25 in. wg DSP)
— 20 Valve/Fan Combinations
— Minimum 16 measuring point flow ring
— Metal encapsulated insulation edges standard for IAQ
— Rugged contractor tough unit construction
— Factory-commissioned controls
— UL and ARI listed
— Factory-mounting customer controls availability
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, and various ‘IAQ’
linings
Enviro-Tech (ETI)
CFR, CFR-WC, and CFR-EH
— 9 fan sizes available, 230–4700 cfm (range based on .25 in. wg DSP)
— 24 valve/fan combinations
— 12-point Flow Star™ flow sensing device, (available for size 6” and above)
— Mechanically fastened insulation
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, and various ‘IAQ’
linings
Green
= Trane is advantaged
Yellow
= Trane is equal
Red
= Trane is disadvantaged
Trane vs. ETI
Page
Transformer ....................................................................................................... 44
Factory-commissioned controls ......................................................................... 40
Manual secondary cutout standard with electric reheat .................................. 38, 43
Flow ring on smaller units (5" inlet) / ETI uses a flow bar .................................. 37, 43
120-volt ECM option ........................................................................................... 44
Air filter .......................................................................................................... 37, 43
Filter frame ..................................................................................................... 37, 43
Fan disconnect ............................................................................................... 37, 43
Hanger brackets ............................................................................................. 37, 43
Dual-wall insulation option .................................................................................. 43
External actuator ................................................................................................ 43
Damper position indicator .................................................................................. 43
Line fuses for electric heat standard for ETI ......................................................... 43
SCR electric heat control ................................................................................ 41, 44
120-volt electric heat option ................................................................................ 44
Fan cfm range ........................................................................................... 44, 48, 51
Electric reheat kW/voltage/staging options .......................................................... 40
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
34
Series
Fan-Powered
Product
Features
Trane
VSCF, VSWF, and VSEF
— 7 Fan sizes available, 280 to 3000 cfm (range based on .25 in.wg. DSP)
— 20 Valve/Fan Combinations
— Minimum 16 measuring point flow ring
— Metal encapsulated insulation edges standard for IAQ
— Rugged contractor tough unit construction
— Factory-commissioned controls
— UL and ARI listed
— Factory-mounting customer controls availability
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, and various ‘IAQ’
linings
Price
FDC, FEC, FPC
— 6 fan sizes available, 250–4000 (range based on .25 in. wg DSP)
— 11 valve/fan combinations
— Factory calibrated to job requirements
— SP-200 multi-point flow sensor with 12 measuring points
— DDC, Analog or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, attenuators, and
various insulations
Green
= Trane is advantaged
Yellow
= Trane is equal
Red
= Trane is disadvantaged
Trane vs. Price
Page
Valve/fan combinations ................................................................................... 43, 46
Lower damper leakage ......................................................................................... 43
More measuring point on our flow ring ............................................................ 37, 43
Water coil access is standard with hot water reheat ............................................ 44
Air filter ........................................................................................................... 37, 43
Filter frame ...................................................................................................... 37, 43
Fan disconnect ................................................................................................ 37, 43
Hanger brackets .............................................................................................. 37, 43
Manual secondary outout for electric reheat ................................................... 38, 43
Factory-commissioned DDC controls .................................................................. 40
Electric heat wire type .......................................................................................... 44
Perforated liner ............................................................................................... 40, 43
SCR electric heat control ................................................................................. 41, 44
120-volt electric heat ............................................................................................ 44
kW range ................................................................................................... 43, 65, 68
Fan cfm range ............................................................................................ 44, 48–51
Attenuators ......................................................................................................... 44
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
35
Series
Fan-Powered
Product
Features
Trane
VSCF, VSWF, and VSEF
— 7 Fan sizes available, 280 to 3000 cfm (range based on .25 in.wg. DSP)
— 20 Valve/Fan Combinations
— Minimum 16 measuring point flow ring
— Metal encapsulated insulation edges standard for IAQ
— Rugged contractor tough unit construction
— Factory-commissioned controls
— UL and ARI listed
— Factory-mounting customer controls availability
— DDC, Analog, or Pneumatic control options
— Options include hot water coils or integral electric coils for reheat, and various ‘IAQ’
linings
Nailor
35S, 35SW, 35SE
— 6 Fan sizes available. 300 – 3700 cfm (range based on .25 in.wg. DSP)
— 15 Valve/Fan Combinations
— Inclined opposed blade damper design
— “Diamond Flow” multi-point averaging sensor with 8 measuring points
— DDC, Analog, Pneumatic control options
— Options include hot water coils or integral electric coil for reheat, attenuators, and
various IAQ linings
Green
= Trane is advantaged
Yellow
= Trane is equal
Red
= Trane is disadvantaged
Trane vs. Nailor
Page
Encapsulated edges ........................................................................................ 37, 43
Factory-commissioned controls ......................................................................... 40
Valve/fan combinations .................................................................................. 43, 46
Lower damper leakage ........................................................................................ 43
Manual secondary cutout for electric reheat .................................................. 38, 43
ARI certified units .......................................................................................... 39, 43
Air filter .......................................................................................................... 37, 43
Filter frame ..................................................................................................... 37, 43
Fan disconnect ............................................................................................... 37, 43
Hanger brackets ............................................................................................. 37, 43
Single-point power ............................................................................................. 44
Transformer standard ......................................................................................... 44
SCR electric heat control ................................................................................ 41, 44
PSC fan cfm range .................................................................................... 44, 48–51
ECM performance ......................................................................................... 73–74
Attenuators ........................................................................................................ 44
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
36
Series
Fan-Powered
Feature
Evaluation
Hanger Brackets/Air Filter/Filter Frame/Fan Disconnect
Trane provides hanger brackets, air filter, filter frame, and a fan disconnect as
standard. WhenTrane is in control of the specifications, make sure that we are
making our competition provide these options in their bill of materials.
Metal Encapsulated Edges
All VariTrane units are complete with metal encapsulated insulation edges.This
encapsulated design arrests cut fibers and prevents erosion of the fibers into the
airstream. As a standard, our competition “butters” the edges of the exposed
insulation with an adhesive spray intended to hold the fibers together. After being
handled, and over time, the adhesive breaks down and allows fibers to escape into
the airstream.This is clearly not equivalent! Specifying VariTrane metal encapsulated
edges will force the competition to add additional dollars to their units. Whether or
notTrane is basis of design, make sure the consultant understands the significance of
metal encapsulated edges.
Suggested Spec
INSULATION EDGE TREATMENT—All cut edges of insulation shall completely
enclosed by metal to arrest cut fibers and prevent erosion into the airstream.
Number of Measuring Points on our Flow Ring (How low can
you go?)
The accuracy of a flow-measuring device is determined by the lowest allowable
minimum cfm setting. Below this cfm, the VAV units will change from pressureindependent (PI) to pressure-dependent (PD) control. Because VariTrane units are
designed to integrate into a DDC control system, the UCM, flow ring, and pressure
transducer create a flow measurement “system” which provides unmatched flow
performance in the VAV industry. Accuracy is +/- 5% from maximum to minimum
cfm. See pp. XX for a comparison ofTrane vs. the competition.
Given:
A consultant is designing a space that requires 800 cfm maximum airflow. Ventilation
is determined by minimum occupancy = 8 persons. 15 cfm/person equates to 120
minimum cfm.
Using the VariTrane Quick Select (VAV-SLP001-EN), the consultant chooses an 8”
inlet.
The 8” VariTrane air valve can have a minimum set as low as 110 cfm.Thus, the 120
cfm minimum is available. Competitor “N” has a minimum which stops at 150 cfm
and can be no lower. Let’s look at the system/cost impact:
Find:
The efficiency impact by having a higher minimum cfm setting.
Assume:
— Unit operates for 3000 hours per year
— Unit is providing reheat 50% of the time.
— Room setpoint (winter) = 70°F
— Supply air = 55°F
Solution:
When in reheat, the VAV unit operates at its minimum airflow. VAV systems typically
have 55°F primary air temperature. Let’s see how this 30 cfm can impact operating
costs:
Qs = 1.085 x cfm x DT
The additional energy required by competitor “N” is
1.085 x 30 cfm x (70 – 55) = 488 Btuh
This equates to 732,375 Btu per year, per 8” valve, which is an increase of 25% in
energy required to reheat the air up to room temperature.
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
37
Series
Fan-Powered
Feature
Evaluation
Suggested Spec
Multi-point, multi-axis flow ring or cross sensor to be furnished and installed by
terminal unit manufacturer. Single-point or flow bar sensors are not acceptable. Flow
sensing device shall be capable of maintaining airflow to within +/- 5 percent of rated
unit airflow setpoint when installed with 1.5 duct diameters straight duct, of the same
size as the primary airflow inlet, upstream from the unit.
Water Coil MBH Performance
Overall, we have the highest MBH performance out of our competition.This high
performance is the result of our higher water pressure drop on the coils. Don’t let the
competition force you into using a 2-row coil if a 1-row coil can supply the specified
MBH performance.
Suggested Spec
Hot Water Heating Coil—Coils shall be factory-installed and shall consist of aluminumplated fins and seamless copper tubes. Fins shall have full fin collars to provide
accurate fin spacing and maximum fin-to-tube contact.Tubes shall be mechanically
expanded into the fin collars. Coils shall be leak tested under water to 450 psig pressure. Supply and return water connections shall be on the same side of the coil.
Water Coil Pressure Drop
At first glance, you will notice thatTrane VAV water coils have a higher water pressure
drop than the competition.Typically, water pressure drop of VAV terminal units is not a
concern of engineers since the units are piped in a two-pipe configuration and the airhandler coil is in the same line.The air-handler water coil pressure drop is what the
pump(s) will be sized for.
Manual Secondary Cutout
“Electric heater shall be complete with automatic reset cutout and manual reset
cutout.The manual reset cutout shall be capable of being reset by a switch, or push
button. Fusible links are not acceptable.”
Why is this important?
A fusible link is a small wire sized to melt when it receives more amperage than it was
designed to handle. Once melted, it can cool and complete the circuit again.This
safety issue is whyTrane no longer uses fusible links.
Additionally, finding of a replacement part for a fusible link may be difficult.Therefore,
the unit would be down for an extended period.
Water Coil Access
All series units have an access panel as standard on the side of the unit. However,
you will still require an access to clean the water coil. When a reheat water coil is
provided, access is provided as standard for coil cleaning. For our competition, this is
an option.
Control Boxes as Standard for Units with NO Controls
What we do:
Field-Installed Controls:
Approximately 50% of VAV controllers in the industry are “plenum rated”.This means
they DO NOT NEED A CONTROL ENCLOSURE. If a control enclosure is required, the
controls supplier should provide it. After all, they know the size, shape, etc. of their
controller. If transformers, disconnects, and/or fuses are factory installed, then a
control enclosure will be provided to house these. (A control box is available as a
design special.)
Factory-Installed Competitive Controls:
When competitive controls are installed in the factory and the controller to be
installed is a plenum rated controller, then no control box will be provided. If the
controller is not plenum rated then a control box will be provided. (A control box is
available as a design special.)
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
38
Series
Fan-Powered
Feature
Evaluation
Analog Controls
Analog controls are a reduced cost solution for the end-user… or are they? Analog
VAV controllers have a similar cost as DDC VAV controllers. What they lack is the
ability to:
— Monitor remotely
— Provide diagnostic data
— Provide feedback to building control panel
— DDC systems can recognize something is broken before it is even noticed by the
occupants. By the time occupants notice, a service technician can already be on the
way.
— Leverage energy saving strategies such as static pressure optimization (required by
ASHRAE 90.1) or Ventilation Reset. (See http://www.trane.com/commercial/issues/iaq/
ashrae.asp.com for additional details)
Acoustics
Make sure you are doing an “apples to apples” comparison. Don’t let the competition
use a less stringent sound power assumption or show cooling only information if reheat is to be used.
Sound Power–if specifying a particular spectrum shape for a particular
manufacturer, this is the same as being a proprietary specification.This is not
advised.
NC (Noise Criteria)–NC level is determined by taking the sound power generated
using ARI 880-98, and applying a transfer function.TheTransfer function assumptions
in ARI 885-98 standard are significantly different than the 90 standard. On average, the
same unit, operating at the same conditions will show a 4 NC improvement if the
older, superceded 90 standard is used. Don’t let the competition catch you in this trap.
Said another way, if your customers specified NC 40 in the space prior to the 98
standard being written, that is now equivalent to NC 44 with the current standard.
ARI Certification
Are the units that are specified ARI certified?
Titus has a quantity of 21 Valve/Fan combinations. However on the ARI web site, only
six are listed as certified units.
Nailor has a total 15 Valve/Fan combinations listed in their catalog. However, on the
ARI web site only 14 of those are listed as certified units.
Trane has a quantity of 19 Valve/Fan combinations. On the ARI web site, all 19 are
listed as certified units.
If sound is going to be critical on specific units, make sure the units that we are
comparing to are listed on the ARI website (www.ariprimenet.org).
UL Rating for Electric Heat
Our units have been tested, approved, and listed with UL as an entire assembly. Most
VAV manufacturing companies have their units ETL listed in accordance with UL
standards.
UL never certifies a product until it passes all the standard requirements and a very
stringent internal review process.The checks and balances system that UL has
always implemented tends to cause delays to which manufacturers are very averse.
In addition, UL has a very comprehensive follow-up program to ensure that products
made after certification continue to be manufactured consistently with the initially
certified and tested product. ETL, on the other hand, is known within the test and
measurement community to be less rigorous in both the certification and the followup of the products that they evaluate.
In short, the ETL Listed Mark indicates that your product has been tested by ITS ETL
SEMKO, found in compliance with accepted national standards, and meets the
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
39
Series
Fan-Powered
Feature
Evaluation
Electric Reheat kW/Voltage/Staging Options
There are many reasons why units with electric reheat are not able to reach certain
higher kWs with 2- and 3-stage, or have certain number of stages with 3-phase units.
The two major limited factors are wire size and the units discharge dimensions.
A heating element requires a certain length and diameter, and the correct number of
elements in order to obtain the correct staging.This determines the ohmage
(resistance) needed to provide the desired kW. Since resistance and kW are inversely
proportional for a given voltage, higher kW heaters need very little element material,
which means changing either the length or the diameter of the wire.
However, there are safety issues, UL and NEC regulations, and manufacturing
practices that limit the diameter from getting too small. Hence, only one alternative
exists and that is to change the length of the wire, which may not be long enough to
fill the discharge area of the heater. Filling the discharge area is important to building a
heater, because it will minimize stratification and will increase the longevity of the
heater by minimizing hot spots.
Factory-Commissioning
Factory-commissioning is more than just factory installed controls!Trane takes great
pride in being the industry leader in factory-commissioned DDC controls.The
following table differentiates these concepts and indicates where options can be
obtained (either the field, or the factory.):
Factory-installed
Transformer optionally installed
X
Wires terminated in reliable/ consistent setting
X
Controller mounted
X
Electric heat contactors and fan relay wired
X
Testing of heater contactors and fan relay
Controller addressing and associated testing
Minimum & Maximum airflows (occupied/unoccupied)
Minimum & Maximum temperature setpoints
(occupied/unoccupied)
Minimum ventilation requirements
(used to calculate ventilation fraction)
Thumbwheel enable/ disable
Heating offset
Factory-commissioned
X
X
X
X
X
X
X
X
X
X
X
Factory-commissioned controllers provide the highest quality and most reliable
controllers for your VAV system. Additional testing verifies proper unit operation
including occupied/unoccupied airflow, temperature setpoints, communication link
functionality, and output device functionality. The benefits of factory-commissioning
are standard on VariTrane terminal units withTrane DDC controls.
Perforated Liners
The intended use of the perforated liner was for units that had a Mylar orTedlar
insulation. Mylar andTedlar insulation was found to have long-term durability
problems and would erode into the airstream over time.The perforated liner was
designed to hold the insulation with the idea to improve acoustical performance over
a dual-wall construction.
Today, if a perforated liner is specified, it is generally used to prevent possible tearing
of the insulation during installation. However, the perforated liner will still allow air to
penetrate the insulation and loft fibers. Our best solution is to use a foil-face or dualwall insulation option.
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
40
Series
Fan-Powered
Feature
Evaluation
SCR Electric Heat Control
Trane does not offer an option for SCR Electric Heat Control. Our competitors use
SCR electric heat control, which is very expensive. We can achieve a modulating kW
operation using our DDC controls. Using pulse-width modulation, our DDC UCM
calculates how far from setpoint the temperature is and what percentage of the
electric heat it need to bring to satisfy the zone.
Suggested Spec
Pulse-Width Modulated (PWM)—At heating setpoint, energize first stage of heat.The
second stage of heating shall be energized based on time and temperature deviation
from setpoint. Duty-cycle these stages on a three-minute window. Stage 1 shall
modulate from 0–50 percent deviation and be on continuously above 50%. Stage 2
shall modulate from 50–100 percent deviation.
Lower Damper Leakage
Our damper leakage rate is 1% @ 4 in. wg and Nailor’s leakage rate is 2% @ 3 in. wg.
Nailor’s higher rate is the result of an opposed blade damper design, which generally
has a higher leakage rate.
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
41
Series
Fan-Powered
Model
Comparison
Model Comparison
VAV Terminal Units
Series
Fan-Powered
Cooling
TRANE
TITUS
ETI
xTQS
CFR
x = D (Digital)
E (Electronic)
P (Pneumatic)
Series
VSWF
xTQS
CFR-WC
Fan-Powered w/
x = D (Digital)
Hot Water Reheat
E (Electronic)
P (Pneumatic)
Series
VSEF
xTQS
CFH-EH
Fan-Powered w/
x = D (Digital)
Electric Reheat
E (Electronic)
P (Pneumatic)
Notes: For Titus and Price replace “x” for control options letter.
VAV-SLM005-EN
VSCF
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
PRICE
NAILOR
FxC
x = D (Digital)
E (Electronic)
P (Pneumatic)
FxC
x = D (Digital)
E (Electronic)
P (Pneumatic)
FxC
x = D (Digital)
E (Electronic)
P (Pneumatic)
35S
35SW
35SE
42
Series
Fan-Powered
Quick
Competitive
Comparison
Quick Competitive Comparison
Series Fan-Powered Comparison
Std. = Standard
D/S = Design Special
Product Offerings
Insulation
Opt. = Optional
N/A = Not Available
Trane
Titus
ETI
Price
Nailor
Std.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
Std.
Opt.
Opt.
Opt.
Opt.
Opt. (3/4")
N/A
N/A
Std.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
N/A
Std. (3/4")
Opt.
Opt.
Opt.
Opt.
Opt. (3/4")
Opt.
N/A
Std. (3/4")
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
N/A
Metal Encapsulated Edges
Edge Spray
Std.
N/A
Opt.
Std.
Std.
N/A
Std.
N/A
Opt.
Std.
Hanger Brackets
Std.
Opt.
Opt.
Opt.
Opt.
Air Filter
Std.
Opt.
Opt.
Opt.
Opt.
Filter Frame
Std.
Opt.
Opt.
Opt.
Opt.
Fan Disconnect
Std.
Opt.
Opt.
Opt.
Opt.
Power Fusing
Opt.
Opt.
Opt.
Opt
Opt.
Std.
Std.
Std.
N/A
Std.
Std.
Std.
Opt.
Std.
Std.
Flange
Std.
Std.
Slip and Drive
Opt.
Opt.
*Note: ETI only has S&D connection on HW reheat as standard.
Std.
Opt.*
Std.
Opt.
Std.
Opt.
1/2" Matte-Faced Insulation
1" Matte-Faced Insulation
1/2" Foil-Faced Insulation
1" Foil-Faced Insulation
1" Dual-Wall Insulation
3/8" Fiber-Free Insulation
Perforated Liner
External Insulation
Insulation Edge Sealant
Access
Unit Access
Built-in Water Coil Access
Outlet Connection
External Actuator
Std.
Std.
Std.
Std.
Std.
Damper Position Indicator
Std.
Std.
Std.
N/A
N/A
Damper Blade Indicator
Quantity of Size Combinations
# of the units listed by ARI
Std.
20
20
Std.
21
6
Std.
24
24
N/A
11
11
N/A
15
6
Damper Leakage @ 3 in. wg
1%
1%
<1%
2%
2%
Flow Star*
+/-5%
12
Flow X
+/-5%
12
Flow Diamond
+/-5%
8
Damper/Fan Combinations
Air Measurement
Flow Sensing Device
Flow Ring
Flow Cross
Accuracy
+/-5%
+/-5%
Min. Number Measuring Points
16
5
*Note: ETI has a single point (flow bar) measuring device for sizes 5
Reheat Offering
Series/Cooling Only
Series/Hot Water Reheat
Series/Electric Reheat
Steam Coils
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
N/A
N/A
Opt.
Opt.
N/A
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
Opt.
Opt.
Opt.
N/A
5.0–40 kW
N/A
Std.
Std.
Opt.
Opt.
Std.
.5–46.5 kW
N/A
Std.
Std.
Std.
Opt.
Opt.
Hot Water Coils
1-Row
2-Row
3-Row
4-Row
Electric Heat Options
VAV-SLM005-EN
kW Range
.5–24.0 kW
.5–30.0 kW
UL Listed Assembly
Std.
N/A
ETL Listed Assembly
N/A
Std.
Automatic Thermal Primary Cutout
Std.
Std.
Manual Secondary Reset
Std.
Opt.
Door Interlock Disconnect
Opt.
Opt.
Line Fuse
Opt.
Opt.
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
.5–32.5 kW
N/A
Std.
Std.
Opt.
Opt.
Opt.
43
Series
Fan-Powered
Quick
Competitive
Comparison
Std. = Standard
D/S = Design Special
Trane
Titus
Electric Heat Options (con't.)
Airflow Switch
Control Transformer
Fan Relay
Magnetic Contactors
Mercury Contactors
P.E. Magnetic Contactors
P.E. Mercury Contactors
SCR Control
Hinged Access Door
NEMA 1 Type Enclosure
Dust Tight Enclosure
Class “A” 80/20 Nickel Chrome Elements
Class “C” 60/16/24 Ni/Ch/Fe Elements
Single-point electrical connection
115/120-volt, 1-phase heater
208/240-volt, 1-phase heater
277-volt, 1-phase heater
347-volt, 1-phase heater
480-volt, 1-phase heater
208-volt, 3-phase heater
240-volt, 3-phase heater
480-volt, 3-phase heater
575-volt, 3-phase heater
600-volt, 3-phase heater
Opt. = Standard Optional
N/A = Option Not Available
ETI
Price
Nailor
Opt.
Std.
Std.
Std.
Opt.
Opt.
Opt.
N/A
Std.
Std.
D/S
N/A
Std.
Std.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
N/A
Std.
Std.
Std.
Std.
Opt.
Opt.
Opt.
N/A
Std.
Std.
Opt.
Std.
N/A
Std.
N/A
Opt.
Opt.
N/A
N/A
Opt.
N/A
Opt.
N/A
N/A
Opt.
Opt.
Std.
Std.
Opt.
Opt.
Opt.
Opt.
Std.
Std.
Opt.
Std.
N/A
Std.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Std.
Std.
Opt.
Opt.
Opt.
N/A
Std.
Std.
N/A
Opt.
Std.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
N/A
Opt.
N/A
Opt.
Std.
Std.
Std.
Std.
Opt.
Opt.
Opt.
N/A
Std.
Std.
Opt.
Opt.
Std.
Std.
N/A
Opt.
Opt.
N/A
N/A
Opt.
N/A
Opt.
N/A
N/A
Std.
Opt.
Std.
Opt.
Std.
Opt.
Std.
Opt.
Std.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
Opt.
Opt.
Opt.
N/A
N/A
Opt.
N/A
N/A
Opt.
Opt.
N/A
Opt.
N/A
N/A
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
N/A
Opt.
Opt.
Opt.
Opt.
N/A
N/A
Opt.
N/A
Opt.
N/A
Opt.
Opt.
Opt.
Motor Type
PSC
ECM
PSC Motor Sizes
115 volt
277 volt
208 volt
347 volt
Horse Power
1/10
1/8
1/6
1/4
1/3
1/2
3/4
1
PSC Cfm Range @ .25 DSP
280–3000 cfm 320–3100 cfm 230–4700 cfm 250–4000 cfm 300–3700 cfm
Motor Speeds
Variable Speed (SCR)
Multi Speed
Note: ETI size 04 fan is 3-speed
Std.
N/A
Std.
N/A
Std.
Std.
Std.
N/A
Std.
N/A
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
D/S
N/A
N/A
Opt.
Opt.
ECM Motor Sizes
120 volt
277 volt
Controls
Direct Digital Controls
Analog Controls
Pneumatic Controls
Other Options
Attenuators
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
44
Series
Fan-Powered
Primary
Inlet Airflow
Ranges (Cfm)
Trane
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
05
06
08
10
12
14
16
0–350
0–500
0–900
0–1400
0–2000
0–3000
0–4000
45–350
60–500
110–900
165–1400
235–2000
320–3000
420–4000
82–350
120–500
210–900
328–1400
470–2000
640–3000
840–4000
65–350
80–500
140–900
220–1400
320–2000
425–3000
560–4000
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
6
8
10
12
14
16
0–500
0–900
0–1400
0–2000
0–3000
0–4000
80–500
145–900
230–1400
325–2000
450–3000
580–4000
80–500
145–900
230–1400
325–2000
450–3000
580–4000
150–500
265–900
415–1400
600–2000
810–3000
1100–4000
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
4
5
6
8
10
12
14
16
16
0–250
0–350
0–550
0–1000
0–1600
0–2300
0–3100
0–4100
0–5500
30–250
50–350
55–530
105–1000
165–1355
240–2300
335–3100
440–4100
600–5500
35–250
50–350
60–550
115–1000
185–1600
285–2300
390–3100
520–4100
600–5500
45–250
65–350
75–490
145–960
235–1545
340–2250
475–3100
625–4100
600–5500
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
6
7
8
9
10
12
14
16
0–450
0–650
0–800
0–1050
0–1350
0–2100
0–3000
0–4000
66–450
99–650
132–800
167–1050
221–1350
304–2100
439–3000
568–4000
66–450
99–650
132–800
167–1050
221–1350
304–2100
439–3000
568–4000
66–450
99–650
132–800
167–1050
221–1350
304–2100
439–3000
568–4000
Inlet
Size
Total Cfm
Range
DDC
Min–Max
Analog
Min–Max
Pneumatic
Min–Max
6
7
8
9
10
12
14
16
18 Oval
0–500
0–710
0–1000
0–1300
0–1435
0–2185
0–2745
0–3730
0–4985
70–500
100–710
150–1000
170–1300
205–1435
260–2185
380–2745
480–3730
770–4985
70–500
100–710
150–1000
170–1300
205–1435
260–2185
380–2745
480–3730
770–4985
85–500
125–710
180–1000
210–1300
250–1435
320–2185
470–2745
590–3730
935–4985
Titus
ETI
Price
Nailor
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
45
Series
Fan-Powered
Valve/Fan
Combinations
Trane VSxF
Fan Sizes
01
02
03
04
05
06
07
4"
(280–500 cfm)
(375–700 cfm)
(540–1130 cfm)
(690–1260 cfm)
(950–1950 cfm)
(1200–2400 cfm)
(1200–3000 cfm)
5"
6"
X
X
X
Inlet Sizes
8"
10"
X
X
X
X
12"
14"
16"
Total
20
X
X
X
X
X
X
X
X
X
X
X
X
X
12"
14"
16"
Titus TQS
Fan Sizes
2
3
4
5
6
7
4"
5"
(320–750 cfm)
(600–1440 cfm)
(820–1550 cfm)
(900–1880 cfm)
(1400–2350 cfm)
(1320–3100 cfm)
6"
X
X
Inlet Sizes
8"
10"
X
X
X
X
X
X
X
X
X
X
X
X
Total
21
X
X
X
X
X
X
X
ETI CFR
Fan Sizes
4"
5"
6"
4 (230–415 cfm)
6 (520–625 cfm)
11 (780–1270 cfm)
18 (1675–2000 cfm)
21 (1700–2275 cfm)
24 (1990–2575 cfm)
30 (3050–3350 cfm)
40 (3125–4200 cfm)
44 (3840–4700 cfm)
X
X
X
X
X
X
8"
Inlet Sizes
10"
12"
14"
16" 16x16" Total
24
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
16"
Total
Price FxC
Fan Sizes
20
30
40
50
60
70
4"
5"
(250–680 cfm)
(550–1200 cfm)
(800–1980 cfm)
(1500–2400 cfm)
(2000–3200 cfm)
(2500–4000 cfm)
6"
X
Inlet Sizes
8"
10"
X
X
12"
14"
11
X
X
X
X
X
X
X
X
Nailor 35S
Fan Sizes
2
3
4
5
6
7
VAV-SLM005-EN
(300–700 cfm)
(400–1140 cfm)
(670–1630 cfm)
(840–2000 cfm)
(1260–2570 cfm)
(1675–3700 cfm)
4"
5"
6"
8"
X
X
X
X
X
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
Inlet
10"
12"
14"
16" 18"oval Total
15
X
X
X
X
X
X
X
X
X
X
46
Series
Fan-Powered
Performance
Data—Size
Comparison
Trane VSxF—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
01
02
03
04
05
06
07
28
28
40
40
40
40
40
38
38
50
50
50
50
50
34.75
34.75
46.75
46.75
46.75
46.75
46.75
22
22
24
24
24
30
30
15.5
15.5
21.5
21.5
21.5
21.5
21.5
4.28
4.28
6.67
6.67
6.67
8.33
8.33
5.53
5.53
11.94
11.94
11.94
14.93
14.93
10.00
10.00
10.00
10.00
10.00
10.00
10.00
6.75
6.75
6.75
6.75
6.75
6.75
6.75
Titus TQS—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
2
3
4
5
6
7
40.875
40.875
40.875
46.875
46.875
46.875
50.625
50.625
50.625
56.625
56.625
56.625
49.875
49.875
49.875
55.875
55.875
55.875
36.125
36.125
36.125
48.125
48.125
48.125
17.125
17.125
17.125
20.125
20.125
20.125
10.25
10.25
10.25
15.67
15.67
15.67
14.63
14.63
14.63
26.27
26.27
26.27
9.75
9.75
9.75
9.75
9.75
9.75
9.00
9.00
9.00
9.00
9.00
9.00
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
3.50
6.63
6.63
11.56
11.56
22.56
35.45
35.45
35.45
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
15.25
10.00
10.00
10.00
10.00
10.00
5.00
5.00
5.00
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
4.67
6.25
8.00
10.56
12.14
20.82
5.44
9.11
11.67
17.59
20.23
34.69
6.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
ETI CFR—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
4
28
40
43.25
18
12
3.50
6
35
47
45
23.375
14
5.68
11
35
47
45
23.375
14
5.68
18
40
52
50
29.375
17
8.16
21
40
52
50
29.375
17
8.16
24
54
66
64
38
19
14.25
30
62
74
67
52
19
22.39
40
62
74
67
52
19
22.39
44
62
74
67
52
19
22.39
Note: Electric heater may extend from 6" to 12", depending on options.
Price FxC—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
20
28
34
37
24
14
30
30
39
39
30
17.5
40
32
41
41
36
17.5
50
38
47
47
40
20
60
38
47
47
46
20
70
54.5
63.5
63.5
55
20
Note: Water coils are 6" w/o access door and 9" w/ access door.
Nailor 35S—Size Comparison
VAV-SLM005-EN
Fan
Size
Cooling
Length
Electric
Heat
Length
H2O
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H2O
Length
Add
2
3
4
5
6
7
36
36
41
41
44
41
48.5
51.25
56.25
56.25
59.25
56.25
48
48
53
53
56
53
18
18
26
26
30
52
14
18
18
18
19
18
4.50
4.50
7.40
7.40
9.17
14.81
5.25
6.75
11.10
11.10
14.51
22.21
12.50
15.25
15.25
15.25
15.25
15.25
12.00
12.00
12.00
12.00
12.00
12.00
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
47
Performance
Data—Fan Airflow
Comparison
Series
Fan-Powered
Trane Fan Performance @ .25" DSP
Cfm
Cooling
Only
` HW
1-row
HW
2-row
Max.
Min.
Max.
Min.
Max.
Min.
Size 01 Size 02 Size 03 Size 04 Size 05 Size 06 Size 07
500
210
475
210
475
210
615
300
580
300
565
300
925
500
905
500
890
500
1150
575
1110
575
1080
575
% Reduction from Cooling Only Max.
Size 1 Size 2 Size 3 Size 4
1-row
2-row
5.0%
5.0%
5.7%
8.1%
2.2%
3.8%
3.5%
6.1%
1677
675
1534
675
1488
675
2350
1000
2100
1000
1900
1000
2500
1300
2150
1300
1900
1300
Size 5
Size 6
Size 7
8.5%
11.3%
10.6%
19.1%
14.0%
24.0%
Titus Fan Performance @ .25" DSP
Cooling
Only
HW
1-row
HW
2-row
Cfm
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
Size 7
Max.
Min.
Max.
Min.
Max.
Min.
—
—
—
—
—
—
600
200
560
200
550
200
1275
410
1150
410
1050
410
1480
830
1275
830
1150
830
1700
650
1600
650
1500
650
2630
1330
2350
1330
2175
1330
—
—
—
—
—
—
Size 5
Size 6
Size 7
5.9%
11.8%
10.6%
17.3%
0.0%
0.0%
% Reduction from Cooling Only Max.
Size 1 Size 2 Size 3 Size 4
1-row
2-row
0.0%
0.0%
6.7%
8.3%
9.8%
17.6%
13.9%
22.3%
ETI Fan Performance @ .25" DSP
Cooling
Only
HW
1-row
HW
2-row
Cfm
Size 4
Max.
Min.
Max.
Min.
Max.
Min.
410
215
400
215
390
215
Size 6 Size 11 Size 18 Size 21 Size 24 Size 30 Size 40 Size 44
595
200
580
200
570
200
1120
100
1090
100
1080
100
1900
800
1850
800
1800
800
2010
1000
1950
1000
1850
1000
2390
1200
2300
1200
2150
1200
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
% Reduction from Cooling Only Max.
Size 4 Size 6 Size 11 Size 18 Size 21 Size 24 Size 30 Size 40 Size 44
1-row
2-row
2.4%
4.9%
2.5%
4.2%
2.7%
3.6%
2.6%
5.3%
3.0%
8.0%
3.8%
10.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
Price Fan Performance @ .25" DSP
Cfm
Cooling
Only
HW
1-row
HW
2-row
Max.
Min.
Max.
Min.
Max.
Min.
Size 20 Size 30 Size 40 Size 50 Size 60 Size 70
—
—
—
—
—
—
675
225
580
225
540
225
1250
500
1100
500
975
500
1900
790
1750
790
1500
790
% Reduction from Cooling Only Max.
Size 2 Size 3 Size 4 Size 5
1-row
2-row
0.0%
0.0%
14.1%
20.0%
12.0%
22.0%
7.9%
21.1%
2450
1490
2150
1490
2000
1490
2900
2000
2750
2000
2525
2000
Size 6
Size 7
12.2%
18.4%
5.2%
12.9%
Nailor Fan Performance @ .25" DSP
Cooling
Only
HW
1-row
HW
2-row
Cfm
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
Size 7
Max.
Min.
Max.
Min.
Max.
Min.
—
—
—
—
—
—
575
150
540
90
540
90
830
150
775
150
775
150
1150
640
1090
640
1090
640
1510
590
1400
590
1400
590
1670
870
1670
870
1670
870
2185
1050
1600
1050
1600
1050
Size 5
Size 6
Size 7
7.3%
7.3%
0.0%
0.0%
26.8%
26.8%
% Reduction from Cooling Only Max.
Size 1 Size 2 Size 3 Size 4
VAV-SLM005-EN
1-row
0.0%
6.1%
6.6%
5.2%
2-row
0.0%
6.1%
6.6%
5.2%
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
48
Series
Fan-Powered
Performance
Data—Fan Airflow
Comparison
Cooling Fan Comparison
05
07
06
TRANE
04
03
02
01
7
6
TITUS
5
4
3
2
44
Fan Size
40
30
28
21
18
ETI
11
06
04
60
50
40
70
PRICE
30
20
6
7
5
2
0
4
3
500
NAILOR
1000
1500
2000
2500
3000
3500
4000
4500
5000
Cfm Range
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
49
Series
Fan-Powered
Performance
Data—Fan Airflow
Comparison
Fan Comparison 1-Row HW Reheat
07
06
05
04
TRANE
03
02
01
7
6
5
TITUS
4
3
2
Fan Size
44
40
24
21
30
ETI
18
11
06
04
60
50
40
PRICE
30
20
6
4
2
70
7
5
NAILOR
3
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
CFM Range
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
50
Performance
Data—Fan Airflow
Comparison
Series
Fan-Powered
Fan Comparison 2-Row HW Reheat
07
06
05
04
02
01
TRANE
03
7
6
5
TITUS
4
3
2
44
Fan Size
40
18
24
21
30
ETI
11
06
04
60
50
40
30
70
20
PRICE
7
6
5
4
2
0
NAILOR
3
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
Cfm Range
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
51
Series
Fan-Powered
Air Pressure Drop – in. wg (I-P)
Air Pressure Drop – in. wg (I-P)
Inlet/Fan Airflow Cooling
Size
Cfm
Only
05–01
06–01
08–01
06–02
08–02
10–02
08–03
10–03
08–04
10–04
280
310
325
350
280
350
425
500
280
350
450
500
375
425
475
500
375
450
525
600
375
500
600
700
540
650
750
900
550
700
900
1100
700
775
850
900
700
800
1000
1200
0.08
0.11
0.12
0.16
0.15
0.24
0.36
0.51
0.05
0.09
0.15
0.19
0.27
0.35
0.44
0.49
0.11
0.16
0.23
0.30
0.07
0.13
0.19
0.26
0.16
0.23
0.32
0.46
0.08
0.13
0.22
0.32
0.29
0.35
0.42
0.47
0.14
0.18
0.27
0.42
12–04
700
850
1000
1250
1000
1150
1250
1400
1000
1300
1600
1900
1175
1200
1300
1400
1200
1500
1800
2000
1500
1800
2100
2400
1500
1800
2100
2400
1200
1500
1800
2000
1500
2000
2500
3000
1500
2000
2500
3000
10–05
12–05
10–06
12–06
14–06
16–06
12–07
14–07
16–07
Performance
Data—Pressure
Requirements
0.10
0.14
0.20
0.33
0.19
0.26
0.31
0.39
0.12
0.22
0.34
0.50
0.19
0.20
0.23
0.27
0.11
0.18
0.26
0.32
0.12
0.18
0.24
0.31
0.12
0.18
0.24
0.31
0.24
0.37
0.53
0.65
0.14
0.24
0.38
0.55
0.10
0.17
0.27
0.39
Fan
Size
Airflow
Cfm
1-Row HW
Coil Only
2-Row HW
Coil Only
01–02
280
400
500
600
700
540
800
1100
1400
1700
1950
1200
1500
2000
2500
3000
0.02
0.04
0.06
0.09
0.11
0.02
0.04
0.07
0.11
0.16
0.20
0.04
0.08
0.17
0.25
0.30
0.05
0.09
0.12
0.17
0.21
0.04
0.08
0.14
0.21
0.29
0.36
0.11
0.16
0.26
0.37
0.50
03–05
06–07
Notes:
1. Electric Coils Only per fan size add 0.01" (3 Pa) to
cooling only value.
2. HW Coil Only pressure drops are just the heating coil.
Titus Air Pressure Drop—in. wg (I—P)
Inlet/Fan Airflow
Size
Cfm
0802
1003
1204
1205
1406
1607
VAV-SLM005-EN
300
400
625
750
600
750
1200
1400
850
1000
1300
1500
900
1100
1500
1800
1500
1700
2250
2500
1800
2150
2700
3100
TQS
Cooling
Fan
Size
Airflow
Cfm
TQS
1-row coil 2-row coil
0.036
2
200
0.01
0.065
425
0.02
0.158
650
0.04
0.228
800
0.06
0.072
3
500
0.03
0.112
700
0.05
0.286
1000
0.09
0.39
1300
0.15
0.072
4
800
0.06
0.099
1040
0.10
0.168
1200
0.13
0.223
1440
0.18
0.057
5
700
0.02
0.086
1120
0.04
0.159
1400
0.06
0.23
1820
0.10
0.098
6
1300
0.05
0.126
1720
0.09
0.221
2000
0.12
0.273
2420
0.16
0.084
7
1500
0.07
0.12
1950
0.11
0.189
2400
0.16
0.249
2700
0.2
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
0.01
0.04
0.08
—
0.05
0.09
0.18
—
0.12
0.19
0.24
—
0.03
0.08
0.12
—
0.10
0.17
0.22
—
0.13
0.21
0.30
—
TQS Elec.
Heat
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
52
Series
Fan-Powered
Performance
Data—Pressure
Requirements
ETI Air Pressure Drop—in. wg (I—P)
Inlet/Fan Airflow
Size
Cfm
0404
0504/
0506
0604/
0606/
0611
0806/
0811/
0818
1011/
1018/
1021
1218/
1221/
1224/
1230
1421/
1424/
1430/
1440
1630/
1640/
1644
1844
VAV-SLM005-EN
100
150
200
250
100
200
250
300
350
200
300
400
450
550
300
400
550
800
1000
600
800
1200
1400
1600
800
1200
1700
2000
2300
1100
1500
2000
2700
3100
1500
1900
2700
3600
4100
2100
2600
3600
4100
4600
CFR
Cooling
Fan
Size
Airflow
Cfm
0.01
0.02
0.03
0.04
0.01
0.02
0.02
0.03
0.04
0.05
0.1
0.19
0.23
0.34
0.03
0.05
0.09
0.11
0.17
0.03
0.06
0.13
0.18
0.24
0.02
0.05
0.09
0.13
0.15
0.04
0.05
0.13
0.13
0.20
0.02
0.04
0.08
0.21
0.28
0.1
0.15
0.3
0.44
0.56
4
100
200
300
400
200
300
400
500
600
400
600
800
1000
1100
700
1000
1200
1600
2000
1000
1400
1600
1800
2000
1000
1400
1800
2200
2400
1500
1700
2100
2500
2900
1700
2100
2500
2900
3700
2400
2800
3600
4400
4600
6
11
18
21
24
30
40
44
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
CFR-WC
1-row coil 2-row coil
0.01
0.02
0.04
0.07
0.01
0.02
0.03
0.04
0.06
0.03
0.06
0.1
0.14
0.17
0.04
0.08
0.11
0.19
0.28
0.08
0.15
0.19
0.23
0.28
0.03
0.05
0.08
0.12
0.14
0.03
0.04
0.06
0.08
0.10
0.04
0.06
0.08
0.10
0.16
0.06
0.08
0.13
0.18
0.20
0.01
0.04
0.08
0.14
0.02
0.03
0.06
0.08
0.12
0.06
0.12
0.19
0.29
0.34
0.09
0.16
0.23
0.38
0.56
0.16
0.3
0.38
0.47
0.56
0.06
0.11
0.17
0.24
0.28
0.06
0.08
0.12
0.16
0.21
0.08
0.12
0.16
0.21
0.32
0.12
0.16
0.26
0.37
0.40
CFR-EH
Elec. Heat
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
53
Series
Fan-Powered
Performance
Data—Pressure
Requirements
Price Air Pressure Drop—in. wg (I-P)
Fan/Inlet Airflow
Size
Cfm
2006
2008
3008
3010
4010
4012
5012
5014
6014
6016
7016
VAV-SLM005-EN
250
300
350
400
400
500
600
700
550
600
650
700
750
800
900
1000
1100
1200
800
950
1100
1250
1000
1250
1500
1750
2000
1500
1700
1900
2100
1600
1800
2000
2200
2400
2000
2200
2400
2600
2800
2400
2600
2800
3000
3200
2800
3100
3400
3700
4000
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
FDC
Cooling
0.10
0.14
0.19
0.24
0.05
0.07
0.10
0.14
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.07
0.09
0.10
0.06
0.08
0.11
0.14
0.03
0.05
0.08
0.11
0.16
0.07
0.09
0.11
0.13
0.04
0.06
0.07
0.09
0.10
0.05
0.06
0.07
0.08
0.09
0.04
0.05
0.06
0.08
0.10
0.02
0.03
0.04
0.04
0.05
FDC
1-row coil 2-row coil
0.04
0.05
0.07
0.08
0.08
0.12
0.17
—
0.08
0.09
0.10
0.11
0.13
0.14
0.17
0.21
—
—
0.08
0.11
0.14
0.18
0.12
0.18
0.24
—
—
0.13
0.16
0.19
0.23
0.14
0.17
0.21
—
—
0.15
0.18
0.21
0.24
—
0.21
0.24
—
—
—
0.12
0.15
0.17
—
—
0.08
0.10
0.13
0.17
0.17
0.25
0.34
—
0.15
0.17
0.20
0.23
0.25
0.28
0.35
0.42
—
—
0.17
0.22
0.29
0.35
0.24
0.35
0.49
—
—
0.26
0.32
0.38
0.45
0.29
0.35
0.42
—
—
0.31
0.36
0.42
0.48
—
0.42
0.48
—
—
—
0.25
0.30
0.35
—
—
FDC Elec.
Heat
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
54
Series
Fan-Powered
Performance
Data—Pressure
Requirements
Nailor Air Pressure Drop—in. wg (I-P)
Inlet/Fan Airflow
Size
Cfm
0802
0803
1003
1004
1204
1205
1405
1406
1607
VAV-SLM005-EN
300
450
550
675
450
600
700
—
450
700
900
1100
850
1000
1100
—
850
1100
1300
1500
1050
1200
1400
1600
1050
1400
1700
1925
1100
1400
2000
2300
1500
2000
3000
3500
35S
Cooling
Fan
Size
Airflow
Cfm
0.05
0.05
0.05
0.05
0.05
0.05
0.05
—
0.05
0.05
0.05
0.05
0.05
0.05
0.05
—
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.04
0.07
0.17
0.24
2
200
300
500
700
400
600
800
1000
700
1000
1200
1400
850
1100
1300
1600
1300
1500
1800
2100
1600
2000
2500
3000
3
4
5
6
7
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
35S
1-row coil 2-row coil
0.01
0.19
0.045
0.078
0.02
0.042
0.07
0.12
0.028
0.053
0.061
0.085
0.038
0.05
0.08
0.11
0.048
0.055
0.085
0.12
0.028
0.48
0.068
0.1
0.02
0.04
0.098
0.18
0.05
0.09
0.16
0.25
0.06
0.12
0.15
0.2
0.85
0.14
0.17
0.25
0.1
0.13
0.18
0.25
0.065
0.11
0.15
0.21
35S Elec.
Heat
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
55
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Trane—Fan Sizes 01, 02 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1
2
3
4
5
1
2
3
4
5
0.16
0.54
1.86
3.87
6.54
9.83
1.02
3.45
7.11
11.89
17.77
2-Row
Capacity
MBH
Airflow (Cfm)
500
550
300
350
400
450
10.06
12.56
14.29
14.98
15.36
15.6
19.08
21.66
22.62
23.12
23.43
10.53
13.3
15.27
16.07
16.51
16.79
20.66
23.85
25.06
25.69
26.09
10.92
13.94
16.13
17.03
17.53
17.84
21.96
25.73
27.19
27.96
28.45
11.24
14.5
16.9
17.9
18.45
18.8
23.07
27.38
29.08
29.99
30.56
11.52
15.02
17.6
18.68
19.28
19.67
24.02
28.84
30.78
31.82
32.47
600
650
700
11.77
15.48
18.23
19.4
20.05
20.47
24.85
30.16
32.32
33.49
34.22
11.99
15.9
18.8
20.06
20.76
21.2
25.59
31.35
33.72
35.02
35.84
12.18
16.28
19.34
20.67
21.41
21.89
26.25
32.44
35.03
36.45
37.35
12.35
16.63
19.83
21.24
22.02
22.53
–
33.45
36.25
37.79
38.77
Trane—Fan Sizes 03, 04, 05 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1
2
3
4
5
6
7
2
3
4
5
6
7
0.37
1.25
2.6
4.37
6.57
9.17
12.17
2.25
4.61
7.68
11.45
15.87
20.95
2-Row
Capacity
MBH
600
800
1000
Airflow (Cfm)
1200
1400
1600
1800
1900
22.25
27.22
29.44
30.69
31.49
32.05
32.46
41.16
44.52
46.3
47.4
48.14
48.68
24.3
30.38
33.22
34.83
35.88
36.62
37.16
47.73
52.72
55.45
57.16
58.33
59.19
25.76
32.88
36.19
38.13
39.4
40.3
40.97
52.42
58.88
62.5
64.81
66.41
67.58
26.87
34.94
38.62
40.87
42.34
43.39
44.17
55.99
63.74
68.2
71.07
73.08
74.56
27.76
36.64
40.7
43.2
44.86
46.04
46.92
58.85
67.77
72.99
76.4
78.8
80.58
28.49
38.08
42.55
45.22
47.05
48.36
49.34
–
71.22
77.16
81.07
83.85
85.92
29.1
39.31
44.16
47.01
49
50.42
51.49
–
74.26
80.88
85.28
88.42
90.77
29.37
39.87
44.89
47.84
49.89
51.37
52.48
–
–
–
–
–
–
Trane—Fan Sizes 06, 07 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
2
3
4
5
6
7
3
4
5
6
7
1.39
2.86
4.8
7.18
10
13.23
5.34
8.88
13.21
18.3
24.12
2-Row
Capacity
MBH
VAV-SLM005-EN
1200
1400
1600
1800
Airflow (Cfm)
2000
2200
2400
2600
2800
2900
42.03
46.71
49.64
51.57
52.93
53.95
68.74
73.59
76.71
78.86
80.45
44.22
49.39
52.68
54.87
56.43
57.6
73.32
79.09
82.84
85.45
87.39
46.05
51.83
55.33
57.76
59.5
60.81
77.17
83.78
88.12
91.18
93.44
47.62
53.94
57.66
60.32
62.23
63.67
80.48
87.87
92.77
96.25
98.85
48.98
55.8
59.83
62.62
64.68
66.24
83.39
91.52
96.96
100.9
103.8
51.24
58.94
63.56
66.63
68.95
70.73
88.38
97.88
104.3
109
112.5
52.2
60.29
65.17
68.44
70.82
72.71
–
100.7
107.7
112.7
116.5
53.07
61.52
66.65
70.1
72.57
74.55
–
–
–
–
–
53.48
62.09
67.35
70.88
73.42
75.42
–
–
–
–
–
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
50.18
57.46
61.79
64.69
66.91
68.59
86
94.83
100.8
105.1
108.3
56
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Titus—Fan Size 2 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.0
2.0
4.0
6.0
.30
.90
3.2
6.5
.60
2.0
6.8
13.9
2-Row
Capacity
MBH
Airflow (Cfm)
500
575
200
275
350
425
12.9
14.1
14.9
15.1
18.0
19.6
20.4
20.7
14.7
16.4
17.4
17.8
21.8
24.4
25.8
26.4
16.0
18.1
19.4
19.9
24.8
28.4
30.6
31.3
17.1
19.5
21.0
21.6
27.3
32.0
34.8
35.8
650
725
800
18.6
21.6
23.5
24.3
31.0
37.7
42.0
43.6
19.6
22.9
25.1
26.0
32.5
40.2
45.2
47.1
20.4
24.1
26.6
27.6
33.8
42.4
48.1
50.3
21.2
25.2
28.0
29.1
—
—
—
—
500
600
700
800
Airflow (Cfm)
900
1000
18.0
20.7
22.4
23.1
29.3
35.0
38.6
39.9
19.0
22.1
24.1
24.9
31.6
38.6
43.1
44.8
20.2
23.7
26.1
27.1
33.4
41.7
47.1
49.2
21.2
25.2
28.0
29.1
35.0
44.4
50.8
53.3
22.9
27.8
31.2
32.6
37.5
48.9
57.1
60.4
1100
1200
1300
23.7
28.9
32.7
34.2
38.5
50.8
59.9
63.6
24.3
30.0
34.0
35.7
39.4
52.6
62.5
66.6
25.0
30.9
35.3
37.1
—
—
—
—
800
880
960
Airflow (Cfm)
1040
1120
1200
21.2
25.2
28.0
29.1
35.0
44.4
50.8
53.3
21.9
26.3
29.3
30.5
36.1
46.3
53.4
56.3
1280
1360
1440
22.6
27.3
30.6
31.9
37.0
48.1
55.9
59.1
23.2
28.3
31.8
33.2
37.9
49.7
58.3
61.7
24.3
30.0
34.0
35.7
39.4
52.6
62.5
66.6
24.8
30.7
35.0
36.8
40.0
53.9
64.4
68.8
25.3
31.5
36.0
37.9
—
—
—
—
25.7
32.2
36.9
38.9
—
—
—
—
Gpm
Water
Pressure
Drop (ft)
700
840
980
Airflow (Cfm)
1120
1260
1400
1.0
2.0
4.0
6.0
1.0
2.0
4.0
5.0
.40
1.3
4.3
8.8
.80
2.6
9.0
13.4
26.6
31.8
35.1
36.4
39.6
50.0
56.4
57.9
1540
1680
1820
28.0
33.8
37.7
39.2
42.1
54.8
63.1
64.9
28.8
35.2
39.5
41.2
44.0
58.8
68.9
71.2
30.2
37.4
42.3
44.2
45.6
62.3
74.2
76.9
33.4
42.7
49.4
52.2
49.0
70.5
87.2
91.2
34.2
44.1
51.4
54.4
49.8
72.6
90.8
95.3
35.0
45.5
53.3
56.6
—
—
—
—
18.0
20.7
22.4
23.1
29.3
35.0
38.6
39.9
Titus—Fan Size 3 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.0
2.0
4.0
6.0
.30
.90
3.2
6.5
.60
2.0
6.8
13.9
2-Row
Capacity
MBH
22.1
26.6
29.7
30.9
36.3
46..8
54.1
57.0
Titus—Fan Size 4 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.0
2.0
4.0
6.0
.30
.90
3.2
6.5
.60
2.0
6.8
13.9
2-Row
Capacity
MBH
23.8
29.1
32.9
34.5
38.7
51.2
60.4
64.2
Titus—Fan Size 5 (I-P)
Rows
1-Row
Capacity
MBH
2-Row
Capacity
MBH
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
31.4
39.3
44.9
47.1
46.9
65.4
78.9
82.1
32.4
41.1
47.2
49.7
48.0
68.1
83.2
86.8
57
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Titus—Fan Size 6 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.0
2.0
4.0
5.0
.40
1.3
4.3
8.8
.80
2.6
9.0
13.4
2-Row
Capacity
MBH
1300
1440
1580
Airflow (Cfm)
1720
1860
2000
2140
2280
2420
31.7
39.8
45.5
47.9
47.3
66.2
80.2
83.5
32.7
41.5
47.9
50.4
48.3
68.8
84.4
88.1
33.6
43.1
50.0
52.8
49.2
71.1
88.3
92.4
34.4
44.5
52.0
55.1
50.0
73.2
91.8
96.4
35.8
47.1
55.6
59.2
51.2
76.7
98.2
103.6
36.5
48.3
57.3
61.1
51.7
78.3
101.0
106.8
37.0
49.3
58.9
62.9
—
—
—
—
37.6
50.4
60.3
64.6
—
—
—
—
1500
1650
1800
Airflow (Cfm)
1950
2100
2250
2400
2550
2700
33.1
42.2
48.8
51.5
48.7
69.8
86.1
90.0
34.0
43.8
51.0
54.0
49.6
72.2
90.1
94.5
34.9
45.3
53.1
56.3
50.4
74.3
93.7
98.6
35.6
46.7
55.0
58.5
51.0
76.1
97.1
102.4
37.5
50.2
60.1
64.4
52.5
80.8
105.9
112.4
38.0
51.2
61.7
66.1
52.9
82.1
108.4
115.3
38.5
52.2
63.1
67.8
—
—
—
—
35.2
45.9
53.9
57.2
50.6
75.0
95.1
100.1
Titus—Fan Size 7 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.0
2.0
4.0
5.0
.40
1.3
4.3
8.8
.80
2.6
9.0
13.4
2-Row
Capacity
MBH
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
36.3
47.9
56.8
60.6
51.6
77.9
100.2
105.9
36.9
49.1
58.5
62.5
52.1
79.4
103.1
109.2
58
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
ETI—Fan Size 4 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1
2
4
5
0.5
1
2
4
5
0.3
1.0
3.5
12.7
—
0.1
0.3
1.0
3.5
5.3
2-Row
Capacity
MBH
Airflow (Cfm)
250
300
100
150
200
5.4
6.0
6.3
6.5
—
7.7
8.6
9.2
9.5
9.6
6.6
7.5
8.1
8.4
—
9.5
11.1
12.1
12.7
12.9
7.5
8.7
9.5
10.0
—
10.7
13.0
14.6
15.5
15.7
8.2
9.7
10.7
11.3
—
11.7
14.6
16.6
17.8
18.1
8.8
10.6
11.7
12.5
—
12.5
15.9
18.4
19.9
20.3
350
400
9.3
11.3
12.7
13.5
—
13.1
17.0
19.9
21.8
22.2
9.7
11.9
13.5
14.5
—
13.6
17.9
21.3
23.5
24.0
ETI—Fan Sizes 6, 11 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1.0
2.0
4.0
5.0
0.5
1.0
2.0
4.0
5.0
0.4
1.4
4.9
17.4
—
0.1
0.4
1.2
4.4
6.6
2-Row
Capacity
MBH
200
300
500
Airflow (Cfm)
600
800
900
1000
1100
9.2
10.6
11.6
12.1
—
12.8
15.4
17.0
17.9
18.1
10.9
13.1
14.5
15.4
—
15.1
19.2
22.0
23.7
24.0
13.1
14.9
16.9
18.1
—
17.6
24.0
29.1
32.4
33.1
13.8
17.7
20.6
22.4
—
18.4
25.7
31.8
35.9
36.8
14.9
19.7
23.3
25.8
—
19.5
28.3
36.1
41.7
43.0
15.4
20.5
24.5
27.2
—
19.9
29.3
37.9
44.2
45.7
15.8
21.2
25.6
28.6
—
20.3
30.2
39.5
46.5
48.1
16.1
21.9
26.6
29.8
—
20.6
31.0
40.9
48.5
50.4
ETI—Fan Sizes 18, 21 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1.0
2.0
4.0
5.0
0.5
1.0
2.0
4.0
5.0
0.4
1.4
4.9
17.4
—
0.1
0.4
1.4
4.9
7.4
2-Row
Capacity
MBH
700
800
1000
Airflow (Cfm)
1200
1400
1600
1800
2000
16.3
21.4
25.3
27.8
—
21.0
30.5
38.5
43.9
45.2
16.8
22.5
26.9
29.8
—
21.5
31.8
40.9
47.2
48.7
17.8
24.3
29.6
33.1
—
22.3
34.0
44.9
53.0
54.9
18.5
25.8
31.9
36.1
—
22.9
35.7
48.2
57.8
60.1
19.1
27.0
33.8
38.6
—
23.4
37.0
50.9
62.0
64.7
19.5
28.0
35.5
40.9
—
23.7
38.0
53.2
65.7
68.8
19.9
28.9
37.0
42.9
—
24.0
38.9
55.2
68.9
72.4
20.3
29.7
38.4
44.8
—
24.2
39.7
57.0
71.9
75.7
1000
1200
1400
Airflow (Cfm)
1600
1800
2000
2200
2400
21.1
30.0
37.3
42.2
—
25.3
40.3
54.7
65.0
67.3
21.9
31.8
40.3
46.3
—
25.8
42.2
58.9
71.5
74.5
22.5
33.4
43.0
49.8
—
26.2
43.7
62.4
77.2
80.8
23.0
34.6
45.2
53.0
—
26.4
44.9
65.4
82.2
86.3
23.8
36.7
49.1
58.4
—
26.8
46.7
70.1
90.6
95.9
24.0
37.5
50.7
60.8
—
27.0
47.0
72.0
94.2
100.0
24.3
38.3
52.2
63.1
—
27.1
47.9
73.8
97.5
103.8
ETI—Fan Size 24 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1.0
2.0
4.0
5.0
0.5
1.0
2.0
4.0
5.0
0.6
2.0
7.1
24.5
—
0.2
0.6
2.0
7.0
10.5
2-Row
Capacity
MBH
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
23.4
35.7
47.3
55.8
—
26.6
45.9
67.9
86.6
91.3
59
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
ETI—Fan Sizes 30, 40 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1.0
2.0
4.0
5.0
0.5
1.0
2.0
4.0
5.0
0.7
2.5
8.7
29.9
—
0.1
0.7
2.6
8.8
13.0
2-Row
Capacity
MBH
1500
1900
2100
Airflow (Cfm)
2300
2500
2900
3300
3700
24.5
37.8
50.2
59.2
—
27.3
47.8
70.9
89.6
94.2
25.2
40.2
54.9
66.1
—
27.6
49.6
76.5
100.1
106.0
25.5
41.1
56.8
69.1
—
27.7
50.3
78.8
104.5
111.1
25.8
42.0
58.6
71.8
—
27.8
50.9
80.7
108.5
115.8
26.0
42.7
60.3
74.4
—
27.9
51.4
82.5
112.2
120.1
26.3
44.0
63.1
79.0
—
28.0
52.1
85.4
118.6
127.8
26.5
45.0
65.6
83.1
—
28.1
52.7
87.8
124.2
134.4
26.7
45.8
67.7
86.7
—
28.1
53.2
89.7
129.0
140.2
2400
2800
Airflow (Cfm)
3200
3600
4000
4400
4600
26.2
43.4
61.4
75.9
—
28.0
51.8
83.6
113.8
121.8
26.5
44.7
64.5
80.9
—
28.1
52.6
86.7
120.8
130.1
26.8
45.7
67.1
85.3
—
28.1
53.2
89.2
126.7
137.2
27.3
48.0
73.1
95.9
—
28.3
54.3
94.4
140.3
153.9
27.3
48.3
73.9
97.4
—
28.3
54.4
95.1
142.1
156.2
ETI—Fan Size 44 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1.0
2.0
4.0
5.0
0.5
1.0
2.0
4.0
5.0
0.8
2.7
9.3
31.8
—
0.1
0.8
2.7
9.3
13.9
2-Row
Capacity
MBH
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
27.0
46.6
69.4
89.2
—
28.2
53.7
91.3
131.8
143.5
27.1
47.4
71.3
92.7
—
28.2
54.0
93.0
136.3
149.0
60
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Price—Fan Size 20 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1.0
2.0
3.0
1.0
2.0
4.0
6.0
.18
.45
1.54
3.17
.45
1.54
5.29
10.88
2-Row
Capacity
MBH
250
300
350
Airflow (Cfm)
400
450
500
550
600
7.3
8.4
9.5
10.1
13.8
16.9
20.2
22.3
7.8
9.1
10.3
11.0
14.6
17.8
21.4
23.6
8.4
9.8
11.1
11.8
15.3
18.7
22.5
24.9
8.9
10.4
11.8
12.6
15.9
19.6
23.6
26.1
9.9
11.6
13.2
14.1
17.2
21.2
25.6
28.3
10.4
12.2
13.9
14.9
17.8
22.0
26.5
29.4
10.9
12.8
14.6
15.6
18.5
22.8
27.5
30.4
9.4
11.0
12.5
13.4
16.6
20.4
24.6
27.2
Price—Fan Size 30 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.5
3.0
6.0
9.0
.22
.82
3.15
6.91
.42
1.43
4.90
10.08
2-Row
Capacity
MBH
550
600
650
Airflow (Cfm)
700
750
800
900
1000
13.8
15.9
17.9
19.0
23.0
28.3
34.0
37.6
14.4
16.6
18.7
19.8
23.7
29.1
35.1
38.8
14.9
17.2
19.4
20.7
24.3
29.9
36.1
39.9
15.5
17.9
20.2
21.5
25.0
30.8
37.1
41.0
16.5
19.2
21.6
23.0
26.2
32.3
39.0
43.2
17.6
20.4
23.1
24.5
27.5
33.9
40.9
45.3
18.7
21.7
24.5
26.0
28.7
35.4
42.7
47.3
16.0
18.5
20.9
22.2
25.6
31.6
38.0
42.1
Price—Fan Size 40 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.5
3.0
6.0
9.0
.28
1.09
4.15
9.10
.55
1.88
6.45
13.27
2-Row
Capacity
MBH
800
900
1000
Airflow (Cfm)
1100
1200
1300
1400
1500
17.8
20.8
23.7
25.3
29.7
36.9
44.8
49.8
18.8
22.0
25.1
26.8
30.9
38.5
46.7
51.9
19.8
23.2
26.5
28.3
32.1
40.0
48.6
54.0
20.8
24.4
27.8
29.7
33.2
41.4
50.4
56.0
22.7
26.7
30.5
32.6
35.5
44.3
53.9
59.9
23.7
27.9
31.8
34.0
36.6
45.7
55.6
61.9
24.7
29.0
33.1
35.4
37.8
47.1
57.4
63.8
21.7
25.6
29.2
31.2
34.3
42.8
52.2
58.8
Price—Fan Size 50 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.5
3.0
6.0
9.0
2.0
4.0
8.0
12.0
.26
.99
3.78
8.28
.56
1.93
6.60
13.58
2-Row
Capacity
MBH
VAV-SLM005-EN
1500
1550
1600
Airflow (Cfm)
1700
1800
1900
2000
2100
29.5
34.6
39.4
42.1
46.1
57.6
70.3
78.2
30.0
35.2
40.1
42.8
46.6
58.3
71.2
79.2
30.5
35.8
40.8
43.5
47.2
59.1
72.1
80.2
31.4
36.9
42.1
45.0
48.3
60.5
73.8
82.2
33.4
39.3
44.8
47.8
50.5
63.3
77.2
86.0
34.4
40.4
46.1
49.3
51.6
64.7
78.9
87.9
35.4
41.6
47.4
50.7
52.7
66.1
80.6
89.8
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
32.4
38.1
43.4
46.4
49.4
61.9
75.5
84.1
61
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Price—Fan Size 60 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.5
3.0
6.0
9.0
3.0
6.0
12.0
18.0
.29
1.13
4.31
9.45
.43
1.47
5.02
10.33
2-Row
Capacity
MBH
2000
2100
2200
Airflow (Cfm)
2300
2400
2500
2600
2700
35.3
41.9
48.1
51.5
61.0
75.7
91.8
101.9
36.2
43.0
49.4
52.9
62.2
77.2
93.6
103.9
37.2
44.1
50.6
54.3
63.4
78.7
95.4
105.9
38.1
45.2
51.9
55.7
64.6
80.2
97.2
107.9
39.1
46.3
53.2
57.0
65.8
81.6
99.0
109.9
40.0
47.5
54.5
58.4
66.9
83.1
100.8
111.8
40.9
48.6
55.7
59.8
68.1
84.6
102.5
113.8
41.9
49.7
57.0
61.1
69.3
86.0
104.3
115.7
Price—Fan Size 70 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.5
3.0
6.0
9.0
3.0
6.0
12.0
18.0
.42
1.61
6.17
13.53
.61
2.10
7.20
14.8
2-Row
Capacity
MBH
VAV-SLM005-EN
2800
2850
2900
Airflow (Cfm)
3000
3100
3200
3300
3400
45.1
55.0
64.4
69.6
81.7
103.4
127.2
142.1
45.4
55.5
65.0
70.3
82.2
104.1
128.0
143.0
45.8
56.0
65.6
70.9
82.8
104.8
128.9
144.0
46.6
57.0
66.7
72.2
83.8
106.1
130.5
145.9
48.2
58.9
69.0
74.7
85.8
108.8
133.9
149.6
48.9
59.9
70.2
75.9
86.9
110.1
135.5
151.4
49.7
60.8
71.3
77.2
87.9
111.4
137.1
153.3
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
47.4
57.9
67.9
73.4
84.8
107.4
132.2
147.7
62
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Nailor—Fan Size 2 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1
2
4
5
0.5
1
2
4
5
<1.0
1.0
3.7
>10.0
>10.0
<1.0
0.27
1.0
3.7
5.5
2-Row
Capacity
MBH
200
300
Airflow (Cfm)
400
500
600
700
8.5
8.7
10.6
11.0
11.1
11.3
13.8
15.4
16.2
16.4
10.0
11.9
13.2
14.0
14.1
13.5
17.4
19.8
21.4
21.8
11.2
13.5
15.2
16.1
16.3
15.0
19.8
23.4
25.9
26.3
12.0
14.9
16.8
18.1
18.5
16.0
21.6
26.4
29.3
30.0
12.6
15.8
18.4
19.7
20.1
17.0
23.2
28.8
32.5
33.5
13.1
16.8
19.5
21.2
21.5
17.5
24.9
31.0
35.2
36.4
Nailor—Fan Size 3 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1
2
4
5
0.5
1
2
4
5
<1.2
1.2
4.4
>10
>10
<.3
0.3
1.2
4.4
7.0
2-Row
Capacity
MBH
300
500
Airflow (Cfm)
700
900
1100
1300
—
12.9
14.2
15.0
15.5
14.1
18.0
20.9
22.5
23.0
12.9
16.1
18.3
19.8
20.0
16.9
23.1
28.2
31.2
32.0
14.2
18.3
21.3
23.1
23.6
18.5
26.2
33.1
37.9
39.0
15.9
21.4
25.5
28.3
29.0
20.2
30.4
40.2
47.8
49.4
16.4
22.2
27.0
30.4
31.1
21.0
31.9
41.9
51.5
53.5
15.1
19.9
23.5
26.0
26.5
19.4
28.9
37.1
43.3
44.8
Nailor—Fan Sizes 4, 5 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1
2
4
5
0.5
1
2
4
5
<.19
0.19
0.73
2.8
4.2
<.15
0.15
0.58
2.2
3.5
2-Row
Capacity
MBH
VAV-SLM005-EN
600
800
Airflow (Cfm)
1000
1200
1400
1600
1800
—
19.1
22.7
25.0
25.6
19.0
27.0
34.0
39.0
40.1
15.7
21.4
25.9
28.9
29.6
20.2
30.0
39.1
45.9
47.6
16.3
23.8
28.2
32.0
33.0
21.0
32.2
43.2
51.6
53.9
18.0
26.0
33.5
39.0
40.4
22.5
36.1
51.4
64.5
68.0
18.3
26.8
34.8
40.9
42.2
23.0
37.1
53.1
67.9
71.4
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
17.0
24.0
30.3
34.8
35.9
21.9
34.0
46.4
56.4
59.1
17.5
25.2
31.8
37.0
38.3
22.1
35.2
47.8
60.8
63.7
63
Series
Fan-Powered
Performance
Data—Hot Water
Coil (I-P)
Nailor—Fan Size 6 (I-P)
Rows
Gpm
1-Row
Capacity
MBH
1
2
4
5
7.5
1
2
4
5
7.5
2-Row
Capacity
MBH
Water
Pressure
Drop (ft)
1000
1200
Airflow (Cfm)
1400
1600
1800
2000
2200
0.18
0.7
2.7
4.0
8.5
25.9
32.4
36.8
37.9
39.4
35.2
37.5
57.4
59.9
63.6
27.5
34.8
40.0
41.3
43.1
37.4
51.3
63.0
66.2
70.2
28.9
36.9
42.9
44.5
46.8
38.7
54.8
67.9
71.5
76.3
29.8
38.6
45.4
45.4
49.2
39.8
57.0
72.5
76.2
82.4
30.5
40.2
47.6
49.4
52.1
41.0
59.5
36.2
80.9
87.5
31.3
41.6
49.6
51.7
54.6
32.0
61.9
79.9
84.9
92.0
31.9
42.8
51.3
53.6
56.8
32.5
63.0
82.6
88.0
96.3
1600
Airflow (Cfm)
1900
2200
2500
2800
3100
Nailor—Fan Size 7 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1300
3400
1-Row
Capacity
MBH
1
0.13
31.2
32.1
34.5
35.9
36.3
37.3
37.8
38.0
2
0.48
41.2
44.8
47.1
49.0
51.2
52.7
53.9
55.5
4
1.9
48.2
53.1
57.5
61.2
63.8
66.3
68.4
71.2
5
2.9
51.2
56.0
60.1
63.9
67.5
70.9
73.1
75.7
7.5
6.0
53.5
58.4
63.8
68.0
72.5
76.1
78.3
81.1
2-Row
1
0.1
40.0
42.1
43.2
44.2
45.0
45.8
46.2
47.1
Capacity
2
0.28
57.6
62.4
66.1
68.6
71.1
72.7
74.8
76.2
MBH
4
1.1
72.5
80.1
87.1
92.5
97.4
101.2
105.0
108.2
5
1.7
77.1
85.8
92.7
99.2
104.7
109.8
113.78
117.6
7.5
3.5
82.5
92.6
101.9
108.8
116.2
123.0
128.8
133.7
Note: Size 2 and 3, 1-row coils are single-circuit. Size 4–7, 1-row coils are multi-circuit. All 2-row coils are multicircuit.
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
64
Series
Fan-Powered
Performance
Data—
Electric Coil
Trane VSEF Electric Coil kW Guidelines—Minimum to Maximum
Fan
Size
Stages
208V/240V
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
0.5–5.5
0.5–5.5
—
0.5–7.0
0.5–7.0
—
0.5–8.0
0.5–8.0
1.0–8.0
0.5–8.0
0.5–8.0
1.0–8.0
0.5–8.0
0.5–8.0
1.0–8.0
0.5–6.0
0.5–6.0
1.0–6.0
0.5–8.0
0.5–8.0
1.0–8.0
01
(280–500 cfm)
02
(375–700 cfm)
03
(540–1130 cfm)
04
(690–1260 cfm)
05
(950–1950 cfm)
06
(1200–2400 cfm)
07
(1200–3000 cfm)
Single-Phase Voltage
277V
347V
1.0–5.5
1.0–5.5
—
1.0–7.0
1.0–7.0
—
1.0–11.0
1.0–11.0
1.0–11.0
1.0–12.0
1.0–12.0
1.0–12.0
1.0–12.0
1.0–12.0
1.0–12.0
1.0–12.0
1.0–12.0
1.0–12.0
1.0–11.0
1.0–11.0
1.0–11.0
1.0–5.5
1.0–5.0
—
1.0–7.0
1.0–7.0
—
1.0–11.0
1.0–11.0
1.5–9.0
1.0–12.0
1.0–12.0
1.5–9.0
1.0–15.0
1.0–15.0
1.5–15.0
1.0–15.0
1.0–15.0
1.5–15.0
1.0–15.0
1.0–15.0
1.5–15.0
480V
1.0–5.5
2.0–4.5
—
1.0–7.0
1.5–5.5
—
1.0–11.0
1.5–11.0
2.5–8.0
1.0–11.0
1.5–11.0
2.5–8.0
1.0–16.0
1.0–16.0
1.5–16.0
1.0–20.0
1.0–20.0
1.5–20.0
1.0–20.0
1.0–20.0
1.5–20.0
Three-Phase Voltage
208V
480V
575V
0.5–5.5
1.5–4.0
—
0.5–7.0
1.0–7.0
—
0.5–11.0
1.0–9.0
1.5–9.0
0.5–12.0
1.0–9.0
1.5–9.0
0.5–14.0
1.0–14.0
1.5–14.0
0.5–12.0
1.0–12.0
1.5–12.0
0.5–14.0
1.0–14.0
1.5–14.0
1.0–5.5
—
—
1.0–7.0
—
—
1.0–11.0
—
—
1.0–12.0
—
—
1.0–16.0
3.0–16.0
4.5–12.0
1.0–22.0
2.0–22.0
3.0–20.0
1.0–24.0
2.0–24.0
3.0–20.0
1.5–5.5
—
—
1.5–7.0
—
—
1.5–9.0
—
—
1.5–9.0
—
—
1.5–16.0
4.5–10.0
—
1.5–22.0
3.0–22.0
5.0–18.0
1.5–24.0
3.0–24.0
5.0–20.0
Fan Electrical Performance
VAV-SLM005-EN
Fan Size
HP
120V
01
02
03
04
05
06
07
1/8
1/8
1/3
1/3
1/2
1/2
1
1.6
1.6
5.4
5.4
7.6
—
—
Max FLA
208V
277V
—
—
—
—
—
6.3
6.9
0.7
0.7
1.8
1.8
2.6
3.8
4.7
347V
0.7
0.7
1.5
1.5
2.1
3.8
3.6
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
65
Series
Fan-Powered
Performance
Data—
Electric Coil
TQS Titus Electric Coil kW Guidelines—Minimum to Maximum
Fan
Size
Stages
208V/240V
Single-Phase Voltage
277V
347V
2
(320–750 cfm)
1
0.5–8.0
0.5–8.0
—
2
1.0–8.0
1.0–8.0
—
3
1.5–8.0
1.5–8.0
—
3
1
0.5–8.0
0.5–11.5
—
(600–1440 cfm)
2
1.0–8.0
1.0–11.5
—
3
1.5–8.0
1.5–11.5
—
4
1
0.5–8.0
0.5–11.5
—
(820–1550 cfm)
2
1.0–8.0
1.0–11.5
—
3
1.5–8.0
1.5–11.5
—
5
1
0.5–8.0
0.5–11.5
—
(900–1880 cfm)
2
1.0–8.0
1.0–11.5
—
3
1.5–8.0
1.5–11.5
—
6
1
0.5–8.0
0.5–11.5
—
(1400–2350 cfm)
2
1.0–8.0
1.0–11.5
—
3
1.5–8.0
1.5–11.5
—
7
1
0.5–8.0
0.5–11.5
—
(1320–3100 cfm)
2
1.0–8.0
1.0–11.5
—
3
1.5–8.0
1.5–11.5
—
Note: Maximum 2 steps electric heat using analog controls.
480V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
575V
1.5–8.5
1.5–8.5
1.5–8.5
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–14.0
1.5–8.5
1.5–8.5
1.5–8.5
1.5–14.0
1.5–14.0
1.5–14.0
1.5–16.0
1.5–16.0
1.5–16.0
1.5–19.0
1.5–19.0
1.5–19.0
1.5–26
1.5–26
1.5–26
1.5–30
1.5–30
1.5–30
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Fan Electrical Performance
VAV-SLM005-EN
Fan Size
HP
120V
Max FLA
208/240V
277V
2
3
4
5
6
7
1/6
1/4
1/3
1/3
3/4
1
4.0
7.0
9.8
10.0
13.4
N/A
1.8
3.0
4.1
4.3
7.2
9.0
1.3
2.4
2.9
3.3
5.4
6.5
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
66
Series
Fan-Powered
Performance
Data—
Electric Coil
CFR ETI Electric Coil kW Guidelines—Minimum to Maximum
Fan
Size
Stages
208V/240V
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
5.0
5.0
5.0
10
10
10
17
17
17
25
25
25
30
30
30
25
25
25
30
30
30
35
35
35
40
40
40
4
(230–415 cfm)
6
(520–625 cfm)
11
(780–1270 cfm)
18
(1675–2000 cfm)
21
(1700–2275 cfm)
24
(1990–2575 cfm)
30
(3050–3350 cfm)
40
(3125–4200 cfm)
44
(3840–4700 cfm)
Single-Phase Voltage
277V
347V
5.0
5.0
5.0
10
10
10
17
17
17
25
25
25
30
30
30
25
25
25
30
30
30
35
35
35
40
40
40
5.0
5.0
5.0
10
10
10
17
17
17
25
25
25
30
30
30
25
25
25
30
30
30
35
35
35
40
40
40
480V
5.0
5.0
5.0
10
10
10
17
17
17
25
25
25
30
30
30
25
25
25
30
30
30
35
35
35
40
40
40
Three-Phase Voltage
208V
480V
575V
5.0
5.0
5.0
10
10
10
17
17
17
25
25
25
30
30
30
25
25
25
30
30
30
35
35
35
40
40
40
5.0
5.0
5.0
10
10
10
17
17
17
25
25
25
30
30
30
25
25
25
30
30
30
35
35
35
40
40
40
5.0
5.0
5.0
10
10
10
17
17
17
25
25
25
30
30
30
25
25
25
30
30
30
35
35
35
40
40
40
Notes:
1. Maximum kW determined by dividing the actual fan capacity (cfm) by 70 (i.e. maximum 70 Cfm per KW= 45° rise)
2. Cfms are at 0.25" w.c.
3. Available kW increments are as follows:
— .5 to 5.0 kW—.25 kW
— 5.0 to 10.0 kW—.5 kW
— Above 10 kW—1.0 kW)
Fan Electrical Performance
VAV-SLM005-EN
Fan Size
HP
4
6
11
18
21
24
30
40
44
1/13
1/6
1/4
1/2
3/4
1
2@1/2
2@3/4
2@1
Max FLA
120V
277V
1.07
2.6
4.9
8.8
9.7
12.3
17.6
22.8
24.6
0.5
0.9
1.9
3.6
3.8
4.5
7.2
8.2
9
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
67
Series
Fan-Powered
Performance
Data—
Electric Coil
F*C Price Electric Coil kW Guidelines—Minimum to Maximum
Fan
Size
Stages
20
(250–680 cfm)
30
(550–1200 cfm)
40
(800–1980 cfm)
50
(1500–2400 cfm)
60
(2000–3200 cfm)
70
(2500–4000 cfm)
Note: Discharge
208V/240V
Single-Phase Voltage
277V
347V
1
9.0/10
10
2
9.0/10
10
3
9.0/10
10
1
8.5/9.5
12.5
2
8.5/9.5
12.5
3
8.5/9.5
12.5
1
7.5/8.5
12.5
2
7.5/8.5
12.5
3
7.5/8.5
12.5
1
7.0/8.5
11.5
2
7.0/8.5
11.5
3
7.0/8.5
11.5
1
7.0/9.5
11
2
7.0/9.5
11
3
7.0/9.5
11
1
5.0/5.5
10.5
2
5.0/5.5
10.5
3
5.0/5.5
10.5
air temperature may not exceed 120°F.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
480V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
575/600V
1.0–10
3.5–10
3.5–10
1.0–14.5
3.5–14.5
3.5–14.5
1.0–13.0
3.5–13.0
3.5–13.0
1.0–12.5
3.5–12.5
3.5–12.5
12.5
12.5
12.5
8.5
8.5
8.5
1.0–10
3.5–10
3.5–10
1.0–17.0
3.5–17.0
3.5–17.0
1.0–28.5
3.5–28.5
3.5–28.5
1.0–34.0
3.5–34.0
3.5–34.0
1.0–33.0
3.5–33.0
3.5–33.0
1.0–32.0
3.5–32.0
3.5–32.0
1.0–10
3.5–10
3.5–10
1.0–17.0
3.6–17.1
3.6–17.1
1.0–28.5
3.5–28.5
3.5–28.5
1.0–34.0
3.5–34.0
3.5–34.0
1.0–42.5
3.5–42.5
3.5–42.5
1.0–46.5
3.5–46.5
3.5–46.5
Fan Electrical Performance
VAV-SLM005-EN
Fan Size
HP
20
30
40
50
60
70
1/8
1/4
1/2
3/4
1
2 3/4
Max FLA
120V
277V
3.4
6.4
11.2
12.2
—
23.2
1.1
2.7
4.0
5.0
8.2
9.4
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
68
Series
Fan-Powered
Performance
Data—
Electric Coil
35SE Nailor Electric Coil W Guidelines—Minimum to Maximum
Fan
Size
Stages
208V/240V
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
0.5–7.0
0.5–7.0
0.5–7.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
2
(150–540 cfm)
3
(150–775 cfm)
4
(650–1080 cfm)
5
(590–1400 cfm)
6
(860–1670 cfm)
7
(1050–2185 cfm)
Single-Phase Voltage
277V
347V
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
480V
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
575V
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
.05–16.0
.05–16.0
.05–16.0
0.5–20.5
0.5–20.5
0.5–20.5
0.5–32.5
0.5–32.5
0.5–32.5
0.5–32.5
0.5–32.5
0.5–32.5
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Notes:
1. Analog electronic controls are limited to maximum 2 stages.
2. Discharge air temperature may not exceed 120°F.
3. A minimum airflow of 70 cfm per kW is required for any given terminal in order to avoid possible nuisance tripping of the thermal cutouts.
Fan Electrical Performance
VAV-SLM005-EN
Fan Size
HP
120V
Max FLA
208V
277V
2
3
4
5
6
7
1/10
1/4
1/3
1/2
3/4
2@1/2
3.3
5.8
6.2
10.1
13.4
20.2
2.0
3.6
4.1
6.5
8.4
13.0
1.0
1.8
2.0
3.3
4.5
6.6
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
69
Series
Fan-Powered
ECM Quick
Competitive
Comparison
Quick Competitive Comparison
Series Fan-Powered Comparison
Trane
Cfm Range @ .25 DSP
450–2300 Cfm
Titus
ETI
Price
Nailor
250–2450 Cfm
100–2375 Cfm
200–2800 Cfm
200–3400 Cfm
Yes
No
No
No
No
.5–22.0 kW
.5–26.0 kW
7.0–25 kW
4.9–36.3 kW
.5–28.0 kW
1-Row MBH Range
22.69–63.52 MBH
21.2–64.6 MBH
9.2–63.1 MBH
7.3–67.1 MBH
11.0–90.0 MBH
2-Row MBH Range
38.83–115.02 MBH
35.0–106.8 MBH
12.8–103.8 MBH
13.8–113.8 MBH
14.2–154.8 MBH
N/A
Opt.
N/A
Opt.
N/A
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
N/A
Opt.
N/A
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
N/A
Opt.
Opt.
Opt.
Opt.
Opt.
—
7.7
—
12.8
—
7.7
—
12.8
—
—
—
—
—
6.5/8.0
—
13.0
—
7.9
12.6/25.2
—
—
4.1
—
6.9
—
4.1
—
6.9
2.6
4.1
5.5
6.9
—
2.0/4.0
—
6.0
—
3.5
5.5/10.9
—
Yes
No
Yes
No
Yes
No
Yes
Yes
Yes
No
ARI Listed ECM units
kW Range
Horse Power Options
1/3 HP
1/2 HP
3/4 HP
1 HP
ECM Motor Sizes
120 volt
277 volt
FLA
120-volt
1/3 HP
1/2 HP
3/4 HP
1 HP
277-volt
1/3 HP
1/2 HP
3/4 HP
1 HP
Units Offered
Series
Parallel
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
70
Series
Fan-Powered
ECM
Valve/Fan
Combinations
Trane VS*F
Fan Sizes
4"
5"
4 (450–1100 cfm)
5 (1000–2300 cfm)
6"
Inlet Size
8"
10"
X
X
X
X
12"
14"
16"
X
X
12"
14"
16"
X
X
X
X
12"
14"
16"
X
X
X
X
X
12"
14"
16"
X
X
14"
16"
18" oval
X
X
Titus TQS
Fan SIzes
4"
5"
6"
04 (450–1350 cfm)
06 (1050–2300 cfm)
Inlet Sizes
8"
10"
X
X
ETI CFRQ
Fan Sizes
4"
5"
11 (100–900 cfm)
19 (700–1400 cfm)
21 (1200–2000 cfm)
24 (1400–2360 cfm)
6"
X
Inlet Sizes
8"
10"
X
X
X
X
Price F*CE
Fan Sizes
4"
5"
20 (200–700 cfm)
40 (400–1800 cfm)
60 (1000–2800 cfm)
6"
X
Inlet Sizes
8"
10"
X
X
X
Nailor 35S
Fan Sizes
3 (200–1100 cfm)
5 (500–2020 cfm)
7 (1500–3400 cfm)
VAV-SLM005-EN
4"
5"
6"
8"
X
X
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
Inlet Sizes
10"
12"
X
X
X
X
71
Series
Fan-Powered
ECM Size
Comparison
Trane VSxF—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H20
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H20
Length
Add
04
05
40
40
50
50
46.75
46.75
24
24
21.5
21.5
6.67
6.67
11.94
11.94
10.00
10.00
6.75
6.75
Titus TQS—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H20
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H20
Length
Add
4
6
40.875
46.875
46.875
52.875
49.875
55.875
36.25
48.25
17.125
20.125
10.29
15.71
14.68
26.34
6.00
6.00
9.00
9.00
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H20
Length
Add
5.68
8.16
9.83
16.45
6.63
11.56
13.92
26.05
12.00
12.00
12.00
12.00
10.00
10.00
10.00
10.00
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H20
Length
Add
14
17.5
20
4.67
8.00
12.14
5.44
11.67
20.23
6.00
9.00
9.00
9.00
9.00
9.00
ETI CFRQ—Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H20
Length
Width
11
35
47
45
23.375
14
19
40
52
50
29.375
17
21
40
52
50
35.375
17
24
50
62
60
47.375
19
Electric Heater may extend from 6" to 12" depending on options.
Price FxC–Size Comparison
Fan
Size
Cooling
Length
Electric
Heat
Length
H20
Length
Width
20
28
34
37
24
40
32
41
41
36
60
38
47
47
46
Water coils are 6" w/o access door and 9" w/ access door.
Nailor 35SST—Size Comparison
VAV-SLM005-EN
Fan
Size
Cooling
Length
Electric
Heat
Length
H20
Length
Width
Height
Cooling
Footprint
(sq ft)
Cooling
Volume
(cu ft)
Electric
Heat
Length Add
H20
Length
Add
3
5
7
36
41
57.25
51.25
56.25
72.5
48
53
69.25
29
41.75
84
18
18
18
7.25
11.89
33.40
10.88
17.83
50.09
15.25
15.25
15.25
12.00
12.00
12.00
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
72
Series
Fan-Powered
ECM Performance
Data—Fan Airflow
Comparison
Cfm
Cooling
Only
HW
1-row
HW
2-row
Max.
Min.
Max.
Min.
Max.
Min.
Size 04 Size 05
1100
450
1100
450
1100
450
2300
1000
2300
1000
2300
1000
Titus Fan Performance @ .25" DSP
Cooling
Only
HW
1-row
HW
2-row
Cfm
Size 4
Size 6
Max.
Min.
Max.
Min.
Max.
Min.
1375
250
1375
250
1375
250
2450
1150
2450
1150
2450
1150
ETI Fan Performance @ .25" DSP
Cfm
Cooling
Only
HW
1-row
HW
2-row
Max.
Min.
Max.
Min.
Max.
Min.
Size 11 Size 19 Size 21 Size 24
900
100
900
100
900
100
1400
700
1400
700
1400
700
2000
1200
2000
1200
2000
1200
2375
1400
2375
1400
2375
1400
Price Fan Performance @ .25" DSP
Cfm
Cooling
Only
HW
1-row
HW
2-row
Max.
Min.
Max.
Min.
Max.
Min.
Size 20 Size 40 Size 60
700
200
700
200
700
200
1800
400
1600
400
1400
400
2800
1000
2400
1000
2200
1000
Nailor Fan Performance @ .25" DSP
Cooling
Only
HW
1-row
HW
2-row
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
Cfm
Size 3
Size 5
Size 7
Max.
Min.
Max.
Min.
Max.
Min.
1100
200
1100
200
1100
200
2025
500
2025
500
2025
500
3400
1500
3400
1500
3400
1500
73
Series
Fan-Powered
ECM Performance
Data— Airflow
Comparison
ECM Fan Range
5
TRANE
4
6
TITUS
4
24
Fan Size
21
ETI
19
11
60
40
PRICE
20
7
5
NAILOR
3
0
500
1000
1500
2000
2500
3000
3500
Cfm Range
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
74
Series
Fan-Powered
ECM Performance
Data— Hot
Water Coil
Trane ECM—Fan Size 04 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1
2
3
4
5
6
7
2
3
4
5
6
7
.36
1.25
2.59
4.36
6.56
9.16
12.15
2.25
4.6
7.67
11.41
15.83
20.90
2-Row
Capacity
MBH
Airflow (Cfm)
700
800
450
500
600
22.69
27.35
29.27
30.34
31.02
31.49
31.84
38.83
41.2
42.46
43.21
43.72
44.09
23.62
28.64
30.78
31.97
32.73
33.26
33.65
41.75
44.65
46.12
47.03
47.65
48.09
25.19
30.90
33.43
34.86
35.77
36.41
36.88
46.72
50.56
52.60
53.85
54.70
55.32
26.46
32.82
35.72
37.36
38.42
39.16
39.71
50.78
55.58
58.15
59.76
60.85
61.64
27.49
34.47
37.71
39.56
40.76
41.60
42.22
54.15
59.86
62.97
64.93
66.27
67.24
900
1000
1100
28.37
35.93
39.49
41.53
42.86
43.79
44.49
57.00
63.57
67.21
69.51
71.09
72.25
29.13
37.30
41.08
43.31
44.76
45.78
46.55
59.44
66.83
70.97
73.61
75.44
76.77
29.75
38.47
42.46
44.85
46.41
47.52
48.34
—
69.59
74.19
77.14
79.19
80.70
Trane ECM—Fan Size 05 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
2
3
4
5
6
7
3
4
5
6
7
1.26
2.61
4.39
6.58
9.19
12.20
4.65
7.75
11.52
15.96
21.05
2-Row
Capacity
MBH
1000
1150
1300
Airflow (Cfm)
1450
1600
1750
37.30
41.08
43.31
44.76
45.78
46.55
66.83
70.97
73.61
75.44
76.77
39.09
43.20
45.68
47.31
48.46
49.32
71.07
75.93
79.05
81.23
82.84
40.63
45.05
47.78
49.57
50.84
51.79
74.71
80.25
83.84
86.36
88.23
41.98
46.74
49.65
51.60
52.98
54.02
77.92
84.09
88.14
90.99
93.10
43.17
48.28
51.34
53.43
54.92
56.04
80.79
87.57
92.05
95.22
97.58
44.23
49.67
52.88
55.11
56.70
57.90
83.40
90.77
95.67
99.15
101.75
1900
2150
2300
45.19
50.93
54.31
56.65
58.34
59.61
85.80
93.74
99.04
102.83
105.67
46.60
52.81
56.49
58.97
60.81
62.20
89.45
98.29
104.26
108.55
111.78
47.30
53.75
57.60
60.15
62.07
63.52
—
100.67
107.00
111.57
115.02
Titus ECM—Fan Size 4 (I-P)
Rows
Gpm
Water
Pressure
Drop
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.0
2.0
4.0
6.0
.30
.90
3.2
6.5
.60
2.0
6.8
13.9
2-Row
Capacity
MBH
800
880
960
Airflow (Cfm)
1040
1120
1200
1280
1360
1440
21.2
25.2
28.0
29.1
35.0
44.4
50.8
53.3
21.9
26.3
29.3
30.5
36.1
46.3
53.4
56.3
22.6
27.3
30.6
31.9
37.0
48.1
55.9
59.1
23.2
28.3
31.8
33.2
37.9
49.7
58.3
61.7
24.3
30.0
34.0
35.7
39.4
52.6
62.5
66.6
24.8
30.7
35.0
36.8
40.0
53.9
64.4
68.8
25.3
31.5
36.0
37.9
—
—
—
—
25.7
32.2
36.9
38.9
—
—
—
—
23.8
29.1
32.9
34.5
38.7
51.2
60.4
64.2
Titus ECM—Fan Size 6 (I-P)
Rows
Gpm
Water
Pressure
Drop
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.0
2.0
4.0
5.0
.40
1.3
4.3
8.8
.80
2.6
9.0
13.4
2-Row
Capacity
MBH
VAV-SLM005-EN
1300
1440
1580
Airflow (Cfm)
1720
1860
2000
2140
2280
2420
31.7
39.8
45.5
47.9
47.3
66.2
80.2
83.5
32.7
41.5
47.9
50.4
48.3
68.8
84.4
88.1
33.6
43.1
50.0
52.8
49.2
71.1
88.3
92.4
34.4
44.5
52.0
55.1
50.0
73.2
91.8
96.4
36.5
48.3
57.3
61.1
51.7
78.3
101.0
106.8
37.0
49.3
58.9
62.9
—
—
—
—
37.6
50.4
60.3
64.6
—
—
—
—
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
35.2
45.9
53.9
57.2
50.6
75.0
95.1
100.1
35.8
47.1
55.6
59.2
51.2
76.7
98.2
103.6
75
Series
Fan-Powered
ECM Performance
Data— Hot
Water Coil
ETI ECM—Fan Size 11 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1–Row
Capacity
MBH
0.5
1.0
2.0
4.0
5.0
0.5
1.0
2.0
4.0
5.0
0.4
1.4
4.9
17.4
—
0.1
0.4
1.2
4.4
6.6
2–Row
Capacity
MBH
200
300
500
Airflow (Cfm)
600
800
900
1000
1100
9.2
10.6
11.6
12.1
—
12.8
15.4
17.0
17.9
18.1
10.9
13.1
14.5
15.4
—
15.1
19.2
22.0
23.7
24.0
13.1
14.9
16.9
18.1
—
17.6
24.0
29.1
32.4
33.1
13.8
17.7
20.6
22.4
—
18.4
25.7
31.8
35.9
36.8
14.9
19.7
23.3
25.8
—
19.5
28.3
36.1
41.7
43.0
15.4
20.5
24.5
27.2
—
19.9
29.3
37.9
44.2
45.7
15.8
21.2
25.6
28.6
—
20.3
30.2
39.5
46.5
48.1
16.1
21.9
26.6
29.8
—
20.6
31.0
40.9
48.5
50.4
ETI ECM—Fan Sizes 19, 21 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1–Row
Capacity
MBH
0.5
1.0
2.0
4.0
5.0
0.5
1.0
2.0
4.0
5.0
0.4
1.4
4.9
17.4
—
0.1
0.4
1.4
4.9
7.4
2–Row
Capacity
MBH
700
800
1000
Airflow (Cfm)
1200
1400
1600
1800
2000
16.3
21.4
25.3
27.8
—
21.0
30.5
38.5
43.9
45.2
16.8
22.5
26.9
29.8
—
21.5
31.8
40.9
47.2
48.7
17.8
24.3
29.6
33.1
—
22.3
34.0
44.9
53.0
54.9
18.5
25.8
31.9
36.1
—
22.9
35.7
48.2
57.8
60.1
19.1
27.0
33.8
38.6
—
23.4
37.0
50.9
62.0
64.7
19.5
28.0
35.5
40.9
—
23.7
38.0
53.2
65.7
68.8
19.9
28.9
37.0
42.9
—
24.0
38.9
55.2
68.9
72.4
20.3
29.7
38.4
44.8
—
24.2
39.7
57.0
71.9
75.7
ETI ECM—Fan Size 24 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1–Row
Capacity
MBH
0.5
1.0
2.0
4.0
5.0
0.5
1.0
2.0
4.0
5.0
0.6
2.0
7.1
24.5
—
0.2
0.6
2.0
7.0
10.5
2–Row
Capacity
MBH
VAV-SLM005-EN
1000
1200
1400
Airflow (Cfm)
1600
1800
2000
2200
2400
21.1
30.0
37.3
42.2
—
25.3
40.3
54.7
65.0
67.3
21.9
31.8
40.3
46.3
—
25.8
42.2
58.9
71.5
74.5
22.5
33.4
43.0
49.8
—
26.2
43.7
62.4
77.2
80.8
23.0
34.6
45.2
53.0
—
26.4
44.9
65.4
82.2
86.3
23.8
36.7
49.1
58.4
—
26.8
46.7
70.1
90.6
95.9
24.0
37.5
50.7
60.8
—
27.0
47.0
72.0
94.2
100.0
24.3
38.3
52.2
63.1
—
27.1
47.9
73.8
97.5
103.8
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
23.4
35.7
47.3
55.8
—
26.6
45.9
67.9
86.6
91.3
76
Series
Fan-Powered
ECM Performance
Data— Hot
Water Coil
Price ECM—Fan Size 20 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1.0
2.0
3.0
1.0
2.0
4.0
6.0
.18
.45
1.54
3.17
.45
1.54
5.29
10.88
2-Row
Capacity
MBH
250
300
350
Airflow (Cfm)
400
450
500
550
600
7.3
8.4
9.5
10.1
13.8
16.9
20.2
22.3
7.8
9.1
10.3
11.0
14.6
17.8
21.4
23.6
8.4
9.8
11.1
11.8
15.3
18.7
22.5
24.9
8.9
10.4
11.8
12.6
15.9
19.6
23.6
26.1
9.4
11.0
12.5
13.4
16.6
20.4
24.6
27.2
9.9
11.6
13.2
14.1
17.2
21.2
25.6
28.3
10.4
12.2
13.9
14.9
17.8
22.0
26.5
29.4
10.9
12.8
14.6
15.6
18.5
22.8
27.5
30.4
Price ECM—Fan Size 40 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.0
2.0
4.0
6.0
1.5
3.0
6.0
9.0
.28
1.09
4.15
9.10
.55
1.88
6.45
13.27
2-Row
Capacity
MBH
800
900
1000
Airflow (Cfm)
1100
1200
1300
1400
1500
17.8
20.8
23.7
25.3
29.7
36.9
44.8
49.8
18.8
22.0
25.1
26.8
30.9
38.5
46.7
51.9
19.8
23.2
26.5
28.3
32.1
40.0
48.6
54.0
20.8
24.4
27.8
29.7
33.2
41.4
50.4
56.0
21.7
25.6
29.2
31.2
34.3
42.8
52.2
58.8
22.7
26.7
30.5
32.6
35.5
44.3
53.9
59.9
23.7
27.9
31.8
34.0
36.6
45.7
55.6
61.9
24.7
29.0
33.1
35.4
37.8
47.1
57.4
63.8
Price ECM—Fan Size 60 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
1.5
3.0
6.0
9.0
3.0
6.0
12.0
18.0
.29
1.13
4.31
9.45
.43
1.47
5.02
10.33
2-Row
Capacity
MBH
VAV-SLM005-EN
2000
2100
2200
Airflow (Cfm)
2300
2400
2500
2600
2700
35.3
41.9
48.1
51.5
61.0
75.7
91.8
101.9
36.2
43.0
49.4
52.9
62.2
77.2
93.6
103.9
37.2
44.1
50.6
54.3
63.4
78.7
95.4
105.9
38.1
45.2
51.9
55.7
64.6
80.2
97.2
107.9
40.0
47.5
54.5
58.4
66.9
83.1
100.8
111.8
40.9
48.6
55.7
59.8
68.1
84.6
102.5
113.8
41.9
49.7
57.0
61.1
69.3
86.0
104.3
115.7
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
39.1
46.3
53.2
57.0
65.8
81.6
99.0
109.9
77
Series
Fan-Powered
ECM Performance
Data— Hot
Water Coil
Nailor ECM—Fan Size 3 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1
2
4
5
0.5
1
2
4
5
<1.2
1.2
4.4
>10
>10
<.3
0.3
1.2
4.4
7.0
2-Row
Capacity
MBH
300
500
Airflow (Cfm)
700
900
1100
1300
—
12.9
14.2
15.0
15.5
14.1
18.0
20.9
22.5
23.0
12.9
16.1
18.3
19.8
20.0
16.9
23.1
28.2
31.2
32.0
14.2
18.3
21.3
23.1
23.6
18.5
26.2
33.1
37.9
39.0
15.9
21.4
25.5
28.3
29.0
20.2
30.4
40.2
47.8
49.4
16.4
22.2
27.0
30.4
31.1
21.0
31.9
41.9
51.5
53.5
15.1
19.9
23.5
26.0
26.5
19.4
28.9
37.1
43.3
44.8
Nailor ECM—Fan Size 5 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1-Row
Capacity
MBH
0.5
1
2
4
5
0.5
1
2
4
5
<.19
0.19
0.73
2.8
4.2
<.15
0.15
0.58
2.2
3.5
2-Row
Capacity
MBH
600
800
Airflow (Cfm)
1000
1200
1400
1600
1800
—
19.1
22.7
25.0
25.6
19.0
27.0
34.0
39.0
40.1
15.7
21.4
25.9
28.9
29.6
20.2
30.0
39.1
45.9
47.6
16.3
23.8
28.2
32.0
33.0
21.0
32.2
43.2
51.6
53.9
17.0
24.0
30.3
34.8
35.9
21.9
34.0
46.4
56.4
59.1
17.5
25.2
31.8
37.0
38.3
22.1
35.2
47.8
60.8
63.7
18.0
26.0
33.5
39.0
40.4
22.5
36.1
51.4
64.5
68.0
18.3
26.8
34.8
40.9
42.2
23.0
37.1
53.1
67.9
71.4
1900
Airflow (Cfm)
2200
2500
2800
3100
Nailor ECM—Fan Size 7 (I-P)
Rows
Gpm
Water
Pressure
Drop (ft)
1300
1600
3400
1-Row
Capacity
MBH
1
0.13
31.2
32.1
34.5
35.9
36.3
37.3
37.8
38.0
2
0.48
41.2
44.8
47.1
49.0
51.2
52.7
53.9
55.5
4
1.9
48.2
53.1
57.5
61.2
63.8
66.3
68.4
71.2
5
2.9
51.2
56.0
60.1
63.9
67.5
70.9
73.1
75.7
7.5
6.0
53.5
58.4
63.8
68.0
72.5
76.1
78.3
81.1
2-Row
1
0.140.0
42.1
43.2
44.2
45.0
45.8
46.2
47.1
Capacity
2
0.28
57.6
62.4
66.1
68.6
71.1
72.7
74.8
76.2
MBH
4
1.1
72.5
80.1
87.1
92.5
97.4
101.2
105.0
108.2
5
1.7
77.1
85.8
92.7
99.2
104.7
109.8
113.78
117.6
7.5
3.5
82.5
92.6
101.9
108.8
116.2
123.0
128.8
133.7
Note: Sizes 2 and 3, 1-row coils are single-circuit. Sizes 4–7, 1-row coils are multi-circuit. All 2-row coils are multicircuit.
VAV-SLM005-EN
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
78
Series
Fan-Powered
ECM Performance
Data—Electric
Coil
VSEF Trane ECM Electric Coil kW Guidelines—Minimum to Maximum
Inlet
Size
Stages
208V/240V
1
2
3
1
2
3
0.5–8.0
1.0–8.0
0.5–8.0
0.5–7.0
0.5–7.0
1.0–7.0
3
(450–1100 cfm)
4
(1000–2300 cfm)
Single-Phase Voltage
277V
347V
1.0–11.0
1.0–11.0
1.0–11.0
0.5–8.0
0.5–8.0
1.0–8.0
—
—
—
—
—
—
480V
1.0–11.0
1.5–11.0
2.5–8.0
1.0–16.0
1.0–16.0
1.5–16.0
Three-Phase Voltage
208V
480V
575V
0.5–11.0
1.0–9.0
1.5–9.0
0.5–12.0
1.0–12.0
1.5–12.0
1.0–11.0
—
—
1.0–16.0
3.0–16.0
4.5–12.0
—
—
—
—
—
—
Notes:
1. Available kW increments are by 0.5 kW from 0.5–8.0 kW, by 1.0 kW from 9.0–17.0 kW, and by 2.0 kW from 18–24.0 kW.
2. All heaters come with an auto-thermal cutout (140°F (60°C)) and manual reset cutout (160° F (71°C)).
ECM Fan Electrical Performance
Max FLA
120VV
277V
Fan Size
HP
04
05
1/2
1
7.7
12.8
4.1
6.9
TQS Titus ECM Electric Coil kW Guidelines—Minimum to Maximum
Inlet
Size
Stages
208V/240V
1
2
3
1
2
3
0.5–7.0
1.0–7.0
1.5–7.0
0.5–9.0
1.0–9.0
1.5–9.0
04
(450–1350 cfm)
06
(1050–2300 cfm)
Single-Phase Voltage
277V
347V
0.5–7.0
1.0–7.0
1.5–7.0
0.5–11.5
1.0–11.5
1.5–11.5
—
—
—
—
—
—
480V
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
575V
1.5–7.0
1.5–7.0
1.5–7.0
1.5–12.0
1.5–12.0
1.5–12.0
1.5–7.0
1.5–7.0
1.5–7.0
1.5–11.0
1.5–11.0
1.5–11.0
Note:
1. KWs assumed same as standard product, as catalog does not indicate otherwise.
ECM Fan Electrical Performance
ECM Fan Electrical Performance
Fan Size
HP
Max FLA
120V
277V
4
6
1/2
1
7.7
12.8
4.1
6.9
CFRQ ETI ECM Electric Coil kW Guidelines—Minimum to Maximum
Inlet
Size
Stages
208V/240V
1
2
3
1
2
3
1
2
3
1
2
3
7.0
7.0
7.0
20.0
20.0
20.0
25.0
25.0
25.0
25.0
25.0
25.0
11
(100–900 cfm)
19
(700–1400 cfm)
21
(1200–2000 cfm)
24
(1400–2360 cfm)
Single-Phase Voltage
277V
347V
7.0
7.0
7.0
20.0
20.0
20.0
25.0
25.0
25.0
25.0
25.0
25.0
7.0
7.0
7.0
20.0
20.0
20.0
25.0
25.0
25.0
25.0
25.0
25.0
480V
Three-Phase Voltage
208V
480V
575V
7.0
7.0
7.0
20.0
20.0
20.0
25.0
25.0
25.0
25.0
25.0
25.0
7.0
7.0
7.0
20.0
20.0
20.0
25.0
25.0
25.0
25.0
25.0
25.0
7.0
7.0
7.0
20.0
20.0
20.0
25.0
25.0
25.0
25.0
25.0
25.0
7.0
7.0
7.0
20.0
20.0
20.0
25.0
25.0
25.0
25.0
25.0
25.0
Notes:
1. Maximum kW determined by dividing the actual fan capacity (cfm) by 70 (i.e. maximum 70 cfm per kW = 45° rise)
2. Cfms are at 0.25" w.c.
3. KWs assumed same as standard product, as catalog does not indicate otherwise.
ECM Fan Electrical Performance
VAV-SLM005-EN
Fan Size
HP
11
19
21
24
1/3
1/2
3/4
1
Max FLA
120V
277V
—
—
—
—
2.6
4.1
5.5
6.9
3-Phase
Neutral Amps
5.4
7.1
9.5
11.9
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
79
Series
Fan-Powered
ECM Performance
Data— Electric
Coil
F*CE Price ECM Electric Coil kW Guidelines—Minimum to Maximum
Inlet
Size
Stages
208V/240V
1
2
3
1
2
3
1
2
3
9.3/10
9.3/10
9.3/10
8.7/10
8.7/10
8.7/10
7.7/8.8
7.7/8.8
7.7/8.8
20
(200–700 cfm)
40
(400–1800 cfm)
60
(1000–2800 cfm)
Single-Phase Voltage
277V
347V
10
10
10
12.5
12.5
12.5
12.2
12.2
12.2
—
—
—
—
—
—
—
—
—
480V
—
—
—
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
575/600V
10
3.6–10
3.6–10
15
3.6–15
3.6–15
13.2
3.6–13.2
3.6–13.2
10
3.6–10
3.6–10
17.1
3.6–17.1
3.6–17.1
28.6
3.6–28.6
3.6–28.6
10
3.6–10
3.6–10
17.1
3.6–17.1
3.6–17.1
28.6
3.6–28.6
3.6–28.6
ECM Fan Electrical Performance
Fan Size
HP
Max FLA
120V
277V
20
40
60
1/2
1/2
1
6.5
8.0
13.0
2.0
4.0
6.0
35S Nailor ECM Electric Coil kW Guidelines—Minimum to Maximum
Inlet
Size
Stages
208V/240V
1
2
3
1
2
3
1
2
3
0.5–7.0
0.5–7.0
0.5–7.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
0.5–8.0
3
(200–1100 cfm)
5
(500–2020 cfm)
5
(1500–3400 cfm)
Single-Phase Voltage
277V
347V
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
.05–11.5
—
—
—
—
—
—
—
—
—
480V
—
—
—
—
—
—
—
—
—
Three-Phase Voltage
208V
480V
575V
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
0.5–14.5
0.5–14.5
0.5–14.5
0.5–7.0
0.5–7.0
0.5–7.0
.05–11.5
.05–11.5
.05–11.5
.05–16.0
.05–16.0
.05–16.0
—
—
—
—
—
—
—
—
—
Notes:
1.KWs assumed same as standard product, as catalog does not indicate otherwise.
2.Three low-height series units are available with 1/3 hp motor(s) providing from 100–1800 cfm.
3.Units are available in standard or “Stealth” design. “Stealth” units have an integral attenuator.
ECM Fan Electrical Performance
VAV-SLM005-EN
Fan Size
HP
3
5
7
1/2
3/4
2@3/4
Max FLA
120V
277V
7.9
12.6
25.2
3.5
5.5
10.9
CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
80
References
Trane
Catalog:
Publication Date:
Literature #:
Web site:
VariTrane™ Products Catalog
July 2001
VAV-PRC005-EN
http://tranenetlax1/Rushville_BU/Home/index.htm
Titus
Catalog:
Publication Date:
Web site:
Product Catalog 2001T2K.1
2001
www.titus-hvac.com
Enviro-Tec
Catalog:
Publication Date:
Web site:
SDR Catalog
October 2001
www.enviro-tec.com
E. H. Price
Catalog:
Publication Date:
Web site:
Air Distribution Products
2000
www.price-hvac.com
Nailor
Catalog:
Publication Date:
Web site:
Trane
A business of American Standard Companies
www.trane.com
For more information contact your local district office
or e-mail us at comfort@trane.com
VAVTerminal Units
May 2001
www.nailor.com
Literature Order Number
VAV-SLM005-EN
File Number
PL-TD-VAV-000-SLM005-EN-1002
Supersedes
New
Stocking Location
Electronic Only
Trane has a policy of continuous product and product data improvement and reserves the right to change
design and specifications without notice.