Siemens SITRANS LR560 specification catalog

Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR560
■ Overview
5
■ Configuration
SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for
continuous monitoring of solids in silos to a range of 100 m
(329 ft).
■ Benefits
• rugged stainless steel design for industrial applications
• 78 GHz high frequency provides very narrow beam, virtually
no mounting nozzle noise, and optimal reflection from sloped
solids
• aimer option to direct beam to area of interest, such as draw
point of cone
• lens antenna is highly resistant to product build up
• air purge connection is included for self-cleaning of extremely
sticky solids
• local display interface (LDI) allows local programming and
diagnostics
■ Application
SITRANS LR560’s plug and play performance is ideal for most
solids applications, including those with extreme dust and high
temperatures to +200 ºC (+392 ºF). Unique design allows safe
and simple programming using the Intrinsically Safe handheld
programmer without having to open the instrument’s lid.
SITRANS LR560 includes an optional graphical local display interface (LDI) that improves setup and operation using an intuitive Quick Start Wizard, and echo profile display for diagnostic
support. Startup is easy using the Quick Start wizard with a few
parameters required for basic operation.
SITRANS LR560 measures practically any solids material to a
range of 100 m (328 ft).
• Key Applications: cement powder, plastic powder/pellets,
grain, coal, wood powder, fly ash
SITRANS LR560 installation
5/2
Siemens FI 01 · 2009
Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR560
■ Technical specifications
Power supply
4 ... 20 mA/HART
Nominal 24 V DC (max. 30 V DC)
with max. 550 
PROFIBUS PA/Foundation Fieldbus
13.5 mA
9 to 32 V DC, per IEC 61158-2
Mode of operation
Measuring principle
Radar level measurement
Frequency
78 GHz FMCW
Minimum detectable distance
400 mm (15.75") from sensor reference point
Maximum measuring range1)
• 40 m (131 ft) version
• 100 m (328 ft) version
Output
• Analog output
4 to 20 mA
• Communications
• HART
• Optional: PROFIBUS PA
• Optional: Foundation Fieldbus
• Fail-safe
• Programmable as high, low or
hold (Loss of Echo)
• NE43 programmable
Performance (according to reference conditions IEC60770-1)
Certificates and approvals
• General
CSAUS/C, CE, FM
• Radio
Europe (R&TTE), FCC, Industry
Canada, C-TICK
• Hazardous
- Europe
ATEX II 3G Ex nA/nL IIC T4 Gc
- Europe/International
ATEX II 1D, 1/2D, 2D
IECEx SIR 09.0149X
Ex ta IIIC T139 ºC Da
- US/Canada
FM/CSA Class II, Div. 1, Groups
E, F, G
Class III T4
FM/CSA Class I, Div. 2,
Groups A, B, C, D, T4
Programming
• Maximum measured error (includ- • Greater of 25 mm (1") or 0.25 %
ing hysteresis and non-repeatabilof range from minimum detectity)
able distance to full range
• Intrinsically Safe Siemens handheld programmer
- Approvals for handheld programmer
Rated operating conditions
(according to reference conditions IEC60770-1)
Installation conditions
• Location
Indoor/outdoor
Ambient conditions (enclosure)
• ambient temperature
-40 to +80 °C (-40 to +176 °F)
• installation category
I
• pollution degree
4
Process temperature
• 40 m version
• 100 m version
IS model:
ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T135°C
Ta = -20 ... +50 °C
CSA/FM Class I, II, and III, Div. 1.,
Gr. A-G, T6 Ta=50C
• Handheld communicator
HART communicator 375/475
• PC
SIMATIC PDM, AMS, PACTware
• Display (local)
Graphic local user interface
including quick start wizard and
echo profile displays
1)
2)
Medium conditions
• Dielectric constant r
Infrared receiver
>2.0
From sensor reference point
Universal flange mates with EN 1092-1 (PN16)/ASME B16.5 (150 lb)/JIS
2220 (10K) bolt hole pattern.
®
HART is a registered trademark of the Hart Communications Foundation.
-40 to +100 °C (-40 to +212 °F)
-40 to +200 °C (-40 to +392 °F)
Design
• Enclosure
- Construction
316L/1.4404 stainless steel
- Conduit entry
M20x1.5, or ½" NPT via adapter
- Lens material
• 40 m version: PEI
• 100 m version: PEEK
• Degree of protection
Type 4X/NEMA 4X,
Type 6/NEMA 6, IP68 with lid
closed
• Weight
3.15 kg (6.94 lb) including 3"
flange
• Optional local display interface
Graphic LCD, with bar graph representing level
■ Accessories
Handheld programmer
Sun Shield Cover
Part number:
7ML1930-1BK
Part number:
7ML1930-1FK
C
Process connections
• Universal flat-faced flanges2)
3, 4, 6"/80, 100, 150 mm, 304
stainless steel
• Universal flat-faced flanges2)
3, 4, 6"/80, 100, 150 mm,
316L/1.4404 or 316L/1.4435
stainless steel
• Aimer flanges2)
3, 4, 6"/80, 100, 150 mm, polyurethane powder-coated cast aluminum
SITRANS LR560 handheld programmer and sun shield cover
Siemens FI 01 · 2009
5/3
5
Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR560
Order No.
C) 7 M L 5 4 4 0 SITRANS LR560
2-wire, 78 GHz FMCW radar level transmitter for
777 0 0 - 7777
continuous monitoring of solids in silos to a range
of 100 m (329 ft).
Order handheld programmer separately!
Order No.
Selection and Ordering data
C) 7 M L 5 4 4 0 SITRANS LR560
2-wire, 78 GHz FMCW radar level transmitter for
777 0 0 - 7777
continuous monitoring of solids in silos to a range
of 100 m (329 ft).
Order handheld programmer separately!
Measurement and process temperature range
40 m (131 ft) max range, -40 to +100 °C
100 m (329 ft) max range, -40 to +200 °C
Instruction manual for PROFIBUS PA device
English
Selection and Ordering data
0
1
Process connection
Universal flat-faced flange fits ANSI/DIN/JIS
flanges
5
3" / 80 mm, 304 stainless steel
4" / 100 mm, 304 stainless steel
6" / 150 mm, 304 stainless steel
A
3" / 80 mm, 316L stainless steel
4" / 100 mm, 316L stainless steel
6" / 150 mm, 316L stainless steel
D
E
F
Enclosure (with cable inlet)
Stainless Steel, 1 X ½" NPT
Stainless Steel, 1 X M20 x 1.5 (plastic gland
included)
G
H
J
A
B
0
1
A
B
C
Approvals
General Purpose, CSAUS/C, Industry Canada, FCC,
CE, R&TTE, C-TICK
CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,
Gr. E,F,G, Class III
A
C) 7ML1998-5XQ81
C)
7ML1998-5LY01
German
Note: The instruction manual should be ordered
as a separate line item on the order.
C)
7ML1998-5LY31
Multi-language Quick Start manual
C) 7ML1998-5XR81
Accessories
Hand Programmer, Intrinsically safe
7ML1930-1BK
Local display interface
7ML1930-1FJ
Sun Shield Cover
7ML1930-1FK
Housing lid with window
7ML1930-1FL
One metallic cable gland M20 x 1.5, rated -40 to
+80 °C (-40 to +176 °F), HART
One metallic cable gland M20 x 1.5, rated -40 to
+80 °C (-40 to +176 °F), PROFIBUS PA
7ML1930-1AP
7ML1930-1AQ
SITRANS RD200 Remote display - see Chapter 8
SITRANS RD500 Remote display - see Chapter 8
C
1)
2)
3)
Local display interface
Without LDI (local display interface)
With LDI (local display interface)
1
2
Order code
Further designs
4)
5)
6)
7)
Rated to 120 ºC max. when used with Pressure rating option 1
Available with Approval option A only
Available with Enclosure option B only
Available with Output/communication options B and C only
Available with Enclosure option A only
Available with Pressure rating option 1 only
Available with Output/communication option A only
®
HART is a registered trademark of HART Communication Foundation
C) Subject to export regulations AL: N, ECCN: EAR99
Please add "-Z" to Order No. and specify Order
code(s).
Plug M12 with mating connector2) 3) 4)
Plug 7/8" with mating connector2) 4) 5)
A50
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 102046)
NAMUR NE43 compliant, device preset to failsafe
<3.6 mA7)
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification (max. 27
characters) specify in plain text
C12
D) Subject to export regulations AL: N, ECCN: EAR99H
A55
N07
Y15
Order No.
C)
7ML1998-5KB01
German
Note: The instruction manual should be ordered
as a separate line item on the order.
C)
7ML1998-5KB31
Multi-language Quick Start manual
C) 7ML1998-5XF81
Siemens FI 01 · 2009
Multi-language Quick Start manual
SITRANS RD100 Remote display - see Chapter 8
B
ATEX II 1 D, ½ D, 2 D, 3G Ex nA/nL, CE, R&TTE,
C-TICK
5/4
7ML1998-5LT31
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
Output/communication
4 to 20 mA, HART®
PROFIBUS PA
Foundation Fieldbus
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
C)
Instruction manual for Foundation Fieldbus
device
English
Pressure rating
0.5 bar g (7.5 psi g) maximum
3 bar g (40 psi g) maximum
Instruction manual for HART device
English
7ML1998-5LT01
German
Note: The instruction manual should be ordered
as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and instruction manual library.
B
C
3" / 80 mm, painted aluminum, with integral aimer1)
4" / 100 mm, painted aluminum, with integral
aimer1)
6" / 150 mm, painted aluminum, with integral aimer 1)
Order No.
C)
Note 1: available with no pressure rating, 0.5 bar g maximum.
Please contact nacc.smpi@siemens.com for special requests.
Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR560
■ Dimensional drawings
5
SITRANS LR560 dimensions
■ Characteristic curves
Temperature derating curve
90
80
Ambient
Temperature
Process
Temperature
Ambient Temperature (ºC)
70
60
50
40
40 m
version
100 m
version
30
20
10
0
0
50
100
150
200
250
Process Temperature (ºC)
SITRANS LR560 temperature derating curve
Siemens FI 01 · 2009
5/5
Level instruments
Continuous level measurement - Radar transmitters
SITRANS LR560
■ Schematics
cable gland
(or NPT cable entry)
cable shield (if used)
Connect the wires
to the terminals as
shown: the polarity
is identified on the
terminal block.
Notes:
1. Depending on the approval rating, glands and plugs may be supplied with
your instrument.
5
2. DC terminal shall be supplied from a source providing electrical isolation between the
input and output, to meet the applicable safety requirements of IEC 61010-1.
3. All field wiring must have insulation suitable for rated input voltages.
4. Use shielded twisted pair cable (14 to 22 AWG) for HART version.
5. Separate cables and conduit may be required to conform to standard
instrumentation wiring practices or electrical codes.
SITRANS LR560 connections
5/6
Siemens FI 01 · 2009