API Audio Accessories 7-22-10 User`s guide

HxM Bluetooth API Guide
Document History
Version
1.1
1.2
1.3
1.4
1.5
1.6
1.7
Date
16-05-2008
14-07-2008
28-08-2008
19-01-2009
19-05-2010
31-05-2010
22-07-2010
Description
Initial version
Added requirement for a security passkey to the security section.
Added comms. packet information
Added HyperTerminal Hardware Check
Remove cadence
Correct stride rollover value to 128
Add Packet Logger Utility
Document Notes
All numbers in this document are written in decimal, except hexadecimal numbers which are prefixed by ‘0x’. For
example 5436 is decimal, while 0x5436 is hexadecimal.
Page 2 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
REFERENCES ........................................................................................................................................ 4
ABBREVIATIONS.................................................................................................................................... 4
INTRODUCTION ..................................................................................................................................... 4
SYSTEM OVERVIEW .............................................................................................................................. 5
4.1. System Architecture ................................................................................................................................. 5
4.2. Connecting to HxM Device ....................................................................................................................... 5
HXM COMMUNICATIONS LINK .............................................................................................................. 8
COMMUNICATIONS PACKET STRUCTURE OVERVIEW ...................................................................... 9
6.1. Basic Message Format ............................................................................................................................. 9
6.1.1.
STX .......................................................................................................................................... 9
6.1.2.
Msg ID ...................................................................................................................................... 9
6.1.3.
DLC .......................................................................................................................................... 9
6.1.4.
Data Payload ............................................................................................................................ 9
6.1.5.
CRC........................................................................................................................................ 10
6.1.6.
ETX ........................................................................................................................................ 10
STANDARD HXM DATA MESSAGE ..................................................................................................... 11
7.1. MSG:0x26 – Heart Rate, Speed & Distance packet ................................................................................ 11
7.1.1.
Packing Format ....................................................................................................................... 12
HARDWARE CHECK USING HYPER TERMINAL ................................................................................. 14
HXM PACKET LOGGER UTILITY ......................................................................................................... 18
9.1. Installation .............................................................................................................................................. 18
9.1.1.
.NET 3.5 SP1 .......................................................................................................................... 18
9.1.2.
HxM Packet Logger................................................................................................................. 18
9.2. Operation ............................................................................................................................................... 19
9.2.1.
RR Log data............................................................................................................................ 21
9.2.2.
1 Hz Log Data ......................................................................................................................... 21
Page 3 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
1. References
Ref #
[1]
ID
9700.0028c
Description
General Comms Link Specification.
2. Abbreviations
Abbreviation
API
ECG
HRM
HxM
PC
RTC
SPP
Description
Application Programmer’s Interface
ElectroCardioGram
Heart Rate Monitor
Heart Rate / Speed and Distance Monitor
Personal Computer
Real Time Clock
Serial Port Profile
3. Introduction
This document is intended as a user’s guide for implementing an API to enable communications with a Zephyr
Technology Bluetooth Heart Rate / Speed & Distance Monitor (HxM)
Page 4 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
4. System Overview
4.1. System Architecture
Mobile Device
HxM
Bluetooth Link
Figure 1 : HxM System Architecture
The diagram above shows that the Bluetooth HxM typically communicates with a mobile device over the Bluetooth
link. The HxM only supports one link at a time and uses the Bluetooth SPP (Serial Port Profile) to communicate
with other devices with the following low-level protocol:
•
•
•
•
115,200 baud
8 data bits
1 stop bit
No parity
4.2. Connecting to HxM Device
The device is discoverable. The discoverable name of the device is HXMXXXXXX where XXXXXX is the
programmed serial number of the HxM device.
When the HxM device is in a connected state it is not discoverable.
The following steps have to be undertaken to connect to a HxM device.
1)
2)
3)
4)
5)
Activate the Bluetooth service of the device/computer wanting to connect to the HxM
Scan for Bluetooth devices in range
Pair with the HxM device found in range
Discover Services of Paired HxM
Connect to serial port of HxM device
The following screenshots show the above process with the standard Microsoft Bluetooth driver and Microsoft
Windows XP Operating System.
Page 5 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
Figure 2 : Scan for Bluetooth devices in range
The device is discoverable. The discoverable name of the device is its serial number.
To connect to the device a passkey must be used.
The passkey is “1234”, and cannot be changed.
Figure 3 : Pair with HxM and provide PIN
Figure 4 : Discover services of HxM device
Page 6 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
Figure 5 : Connect to Bluetooth HxM serial port
Figure 6 : Connected to Bluetooth HxM serial port
Page 7 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
5. HxM Communications Link
Once a Bluetooth connection has been established with the HxM, the data packets can be received by the
connecting device. The following sequence diagram shows an example session:
Mobile Device or PC
HxM
Bluetooth Link
Heart Rate, Speed & Distance Packet
1 Second
Figure 7 : Example link session
The diagram shows that after the mobile device has connected to the HRM it receives a data packet from the
HxM at 1 second intervals.
The Heart Rate, Speed & Distance message cannot be disabled. The device will not respond to or acknowledge.
Page 8 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
6. Communications Packet Structure Overview
The serial communication between the HxM device and the paired device operates in a simplex mode. The HxM
device transmits the HxM data packet and does not process any received data.
6.1. Basic Message Format
HxM Transmitted Data Packet:
STX
Msg ID
Data Payload
DLC
Number of bytes in
the Data Payload
0…128 bytes
CRC
ETX
Calculated over the
Data Payload area
Figure 8 : Basic Message Format
6.1.1.
STX
The STX field (Start of Text) is a standard ASCII control character (0x02) and denotes the start of the message.
Although the protocol does not guarantee this value will not appear again within a message, it gives some
delimiting to the message and therefore a start character to search for when receiving data.
6.1.2.
Msg ID
The Message ID uniquely identifies each message type and is in binary format. For the HxM the message ID is
0x26 for the standard HxM data packet.
6.1.3.
DLC
The Data Length Code is used to specify the number of bytes within the data payload field of the message. Valid
values range between zero and 128 (inclusive). For the standard HxM data packet the DLC has a value of 0x37.
6.1.4.
Data Payload
This field contains the actual data sent between the local and remote units and can contain anywhere between
zero and 128 bytes of data. The number of bytes in this field is dictated by the DLC field.
Page 9 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
6.1.5.
CRC
An 8-bit CRC is used and has a polynomial of 0x8C (CRC-8), with the accumulator being initialised to zero before
the CRC calculation begins. The following source code indicates the required implementation:
crc:
Ch:
The current CRC.
Value to add to the CRC calculation.
Void crc8PushByte(uint8_t *crc, uint8_t ch)
{
uint8_t i;
*crc = *crc ^ ch;
for (i=0; i<8; i++)
{
if (*crc & 1)
{
*crc = (*crc >> 1) ^0x8C;
}
else
{
*crc = (*crc >> 1);
}
}
}
pcrc: Pointer to running CRC to update (set this to something before first call).
Block: Pointer to the.block of data to push through.
Count: The number of bytes to push.
Return:
The computed CRC (result also updated in pcrc if that is non-NULL).
Uint8_t crc8PushBlock(uint8_t *pcrc, uint8_t *block, uint16_t count)
{
uint8_t crc = pcrc ? *pcrc : 0;
for (; count>0; --count,block++)
{
crc8PushByte(&crc, *block);
}
if (pcrc) *pcrc = crc;
return crc;
}
6.1.6.
ETX
The ETX field (End of Text) is a standard ASCII control character (0x03) and denotes the end of the message.
Page 10 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
7. Standard HxM Data Message
7.1. MSG:0x26 – Heart Rate, Speed & Distance packet
This message contains the heart rate data, including the last 15 RR timestamps, and speed & distance data. The
packet is transmitted periodically at 1Hz.
Byte/Bit
0
1
2
3
5
7
9
11
12
13
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
55
56
58
59
7
Table 7.1
6
5
4
3
2
1
STX
0x26
55
Firmware ID
Firmware Version
Hardware ID
Hardware Version
Battery Charge Indicator
Heart Rate
Heart Beat Number
Heart Beat Timestamp #1 (Newest)
Heart Beat Timestamp #2
Heart Beat Timestamp #3
Heart Beat Timestamp #4
Heart Beat Timestamp #5
Heart Beat Timestamp #6
Heart Beat Timestamp #7
Heart Beat Timestamp #8
Heart Beat Timestamp #9
Heart Beat Timestamp #10
Heart Beat Timestamp #11
Heart Beat Timestamp #12
Heart Beat Timestamp #13
Heart Beat Timestamp #14
Heart Beat Timestamp #15 (Oldest)
Reserved
Reserved
Reserved
Distance
Instantaneous speed
Strides
Reserved
Reserved
CRC
ETX
0
Field
STX
Msg ID
DLC
Payload
CRC
ETX
Message: Heart Rate, Speed & Distance Packet
Page 11 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
7.1.1.
Packing Format
All bytes are little endian.
All 16 bit unsigned integers are sent least significant byte first.
Firmware ID & Version
Zephyr Firmware releases are identified with identification codes of the following form “9500.xxxx.Vyz” where xxxx
is a number indentifying the firmware type (0000 - 9999), and y is the major version (1 – 9) and z is the minor
version (A – Z, or a-z).
The firmware ID field represents xxxx, and the firmware version field is two ASCII bytes representing yz.
Hardware ID & Version
Zephyr Hardware releases are identified with identification codes of the following form “9800.xxxx.Vyz” where
xxxx is a number indentifying the product (0000 - 9999), and y is the major version (1 – 9) and z is the minor
version (A – Z, or a-z).
The hardware ID field represents xxxx, and the hardware version field is two ASCII bytes representing yz.
Battery Charge Indicator
The battery charge indicator is an unsigned byte, representing the percentage of charge remaining. The valid
range is 0 to 100%.
The unit will continue to run for a short time once the charge indication has reached 0%.
Heart Rate
The heart rate is an unsigned byte, representing the heart rate in beats per minute.
The valid range is 30 to 240bpm, but the value will go to zero if no valid heart beat is detected within the timeout
period.
Heart Beat Number
The heart beat number is an unsigned byte, which is incremented each time a heart beat event is detected.
The valid range is 0 – 255. The count rolls over after 255.
This enables the receiver to determine how many new heart beat timestamps are present in the received packet,
even in the event of a dropped packet.
Page 12 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
Heart Beat Timestamp (1 to 15)
The heart beat timestamp is a 16 bit unsigned integer, representing the time at which the heart beat occurred, in
milliseconds. (Valid range 0 – 65535ms)
The time used to populate the timestamp rolls over after 65535ms. This should be taken into consideration when
calculating the heart beat interval (RR time).
The R to R data consists of a series of R-detection timestamps with 1 millisecond resolution. The internal clock
rolls over at 65535 ms.
Figure 9 : PQRS Waveform showing the R-R Interval.
The R to R interval is the time between subsequent R peaks in an ECG waveform.
15 values are sent, such that at the fastest valid heart rate (240bpm) 3 consecutive packets can be dropped
without loss of information. Timestamp #1 is the most recent heart beat and timestamp #15 is the oldest.
Distance
The distance is a 16 bit unsigned integer, representing the cumulative distance travelled since the device was
powered on, in 16ths of a meter (valid range 0 to 4095).
The distance travelled rolls over every 256m.
Instantaneous speed
The Instantaneous speed is a 16 bit unsigned integer, representing the Instantaneous speed of the wearer in
steps of 1/256m/s. The valid range is 0 – 4095 steps or 0 to 15.996m/s.
Strides
The strides count is an unsigned byte, representing the number of strides since the unit was powered on. The
valid range is 0 to 255 strides. The number of strides rolls over every 128 strides.
Page 13 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
8. Hardware Check Using Hyper Terminal
The following steps can be used to confirm output from the device using Hyper Terminal. In this example, the
Bluetooth Utility used is IVT BlueSoleil in a desktop PC in conjunction with a USB Bluetooth dongle.
1. Start your Bluetooth utility and establish a connection with the HxM
In the example above the device is HxM001127
2. Establish a Connection with the device using Passkey ‘1234’
Page 14 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
3. Determine which COM Port is being used:
The Serial Port Service is COM47 in this example
Use Windows > Start > All Programs > Accessories > Communications > Hyper Terminal
Enter ‘HxM Test’ or similar as a New Connection name.
Page 15 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
4. Select the COM Port from the pulldown list and click OK
5. Set the Connection Properties as shown
Page 16 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
6. The Hyper Terminal Window should now show output from the device
Note that the device outputs binary data. Hyper Terminal displays this as ASCII.
Notes:
1. The device has wear-detect circuitry which switches on data output. If no data is observed, moisten the
sensors pads with water.
Excessively dry skin may not have sufficient conductivity to turn the device on.
Page 17 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
9. HxM Packet Logger Utility
A PC Tool is included as part of the SDK to allow you to receive and record data from a PC with a Bluetooth
Interface. This can be a native PC Bluetooth card, or a Bluetooth USB dongle.
9.1. Installation
9.1.1.
.NET 3.5 SP1
This utilities requires that Microsoft® .NET3.5SP1 be installed on your PC for it to operate (this framework is
embed in Windows 7).
To install, browse the CD to locate
.. \BT HxM SDK\Microsoft\DotNetFX35SP1\dotNetFx35setup.exe
And double-click to install the software. Follow the Microsoft wizard instructions.
9.1.2.
HxM Packet Logger
To install, browse the CD and locate
.. \BT HxM SDK\BT HxM Packet Logger\setup.exe
And follow the installation wizard.
A desktop shortcut will be installed.
Page 18 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
9.2. Operation
In order to use the Packet Logger, you must determine which COM Port is receiving the HxM data. Wear the
device and moisten the sensor pads to power it on.
Use the Bluetooth Interface of your PC, or that supplied with your Bluetooth USB dongle, to display the Properties
of the connection to the device:
Note the COM Port number which has been allocated to the connection.
Page 19 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
Start the Packet Logger utility, enter the COM Port number, and click Open to start the tool:
To record data, click the browse buttons
, find a suitable location and enter the name of the file you want
recorded. Do this for both the RR Log (text) file and the 1Hz Log (.csv) file
Page 20 of 21
Ph: 1-443-569-3603
9700.0031
Fax: 1-443-926-9402
© Zephyr Technology 2010
Web: www.zephyr-technology.com
2010-07-22
Click the Start Logging button to create the log files. Click Stop Logging when required.
Note: Each time the Start Logging button is clicked subsequently, the utility will overwrite any data already in the
file displayed in the log file path. A new file must be created prior to clicking the Start Logging button if you don’t
want to over-write data already recorded.
9.2.1.
RR Log data
The text file contains heart rate RR intervals, measured in milliseconds. There is no timestamp information.
9.2.2.
1 Hz Log Data
The .csv file contains columns corresponding to lines 3 – 56 in Table 7.1