HMP230 series legacy configuration codes

Legacy configuration codes
Valid from 25th February 2003
HMP231 Humidity and Temperature Transmitter
For wall mounting
Industrial humidity and temperature transmitter
Transmitter
RH+T
RH+T+Td
type
RH+T+a+Tw+x
Display
Probe length
Power supply &
connectors
Using serial interface:
HMP231
A
PRICE
A
A
B
C
RH+T+Td+a+Tw+x+h
RH+T+h
no display
display on transmitter cover
120 mm
D
F
1
2
A
0
4
8
9
9
24 V, no connectors
24 V, shared connector for power supply and analog outputs
24 V, connector for RS232C
24 V, 2 connectors: RS232C and analog outputs+power supply
24 V, 2 connectors shared for power supply and RS485
Serial interface
RS 232C
RS 485/RS 422
current loop
Sensor protection
sintered stainless steel filter (16452)
PPS plastic grid & stainless steel netting (16720HM)
PPS plastic grid (16562)
Analog output
4...20 mA
signals
0...20 mA
(Ch1 and Ch2)
0...1 V
0...5 V
0...10 V
channel 1
channel 2
Parameters for the
RH
(0...100 %RH)
analog outputs
T
(range: see below)
(If available in the
Td
(-40...+60 °C)
(-40...+140 °F)
chosen transmitter
a
(0...160 g/m3)
(0...69.9 gr/ft3)
type)
Tw
(0...+60 °C)
(+32...+140 °F)
x
(0...160 g/kg d.a.)
(0...1120 gr/lb)
h
(-40...+460 kJ/kg)
(-17.2...+197.8 Btu/lb)
(Ch1 and Ch2)
channel 1
channel 2
Analog output range -20...+60 °C
(-4...+140 °F)
for temperature
-40...+60 °C
(-40...+140 °F)
0...+60 °C
(+32...+140 °F)
Units (local display metric
and serial interface) non-metric
Regaining option *) no regaining
(HUMICAP K)
regaining
(HUMICAP KC)
and sensor type
Manual language
No manual
English
German
French
Finnish
A
B
C
1
2
3
A
B
C
D
E
A
B
C
D
E
1
2
3
4
5
6
7
1
2
3
4
5
6
7
A
B
C
1
2
A
3
2
A
B
C
D
E
TOTAL
QTY
TOTAL VALUE
*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.
If the regaining option is chosen, the sensor must be protected either with a sintered filter or
with a PPS plastic grid with steel netting; the PPS plastic grid can not be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
HMP231 A
End customer:
1
A
0
A
1
A
A
1
2
A
1
A
3
B
Legacy configuration codes
Valid from 25th February 2003
HMP233 Humidity and Temperature Transmitter
With compact probe
Industrial humidity and temperature transmitter
Transmitter
RH+T
RH+T+Td
type
RH+T+a+Tw+x
Display
Probe cable length
Power supply,
alarm output &
connectors
Using serial interface:
Serial interface
Sensor protection
Analog output
signals
(Ch1 and Ch2)
RH+T+Td+a+Tw+x+h
RH+T+h
no display
display on transmitter cover
2 m cable, +80 °C
5 m cable, +80 °C
10 m cable, +80 °C
2 m cable, +120 °C
5 m cable, +120 °C
10 m cable, +120 °C
HMP233
PRICE
A
B
C
D
F
1
2
(176 °F)
(176 °F)
(176 °F)
(+248°F)
(+248°F)
(+248°F)
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
9
24 V, no connectors
115 V, no connectors
230 V, no connectors
24 V, + alarm output unit (no connectors)
24 V, shared connector for power supply and analog outputs
24 V, as above + alarm output unit not on connector
115 V, connector for analog outputs
230 V, connector for analog outputs
24 V, connector for RS232C
24 V, 2 connectors: RS232C and analog outputs+power supply
24 V, 2 connectors shared for power supply and RS485
RS 232C
RS 485/RS 422
current loop
PPS plastic grid & stainless steel netting (16720HM)
4...20 mA
0...20 mA
0...1 V
0...5 V
0...10 V
A
B
C
2
A
B
C
D
E
A
B
C
D
E
channel 1
channel 2
Parameters for the
analog outputs
(If available in the
chosen tranmitter
type)
(Ch1 and Ch2)
RH
T
Td
a
Tw
x
h
(0...100 %RH)
(range: see below)
(-40...+100 °C)
(0...600 g/m3)
(0...+100 °C)
(0...500 g/kg d.a.)
(-40...1500 kJ/kg)
1
2
3
4
5
6
7
(-40...+212 °F)
(0...262 gr/ft3)
(+32...+212 °F)
(0...3500 gr/lb d.a.)
(-17.2...644.9 Btu/lb)
channel 1
channel 2
(-4...+176 °F)
(-4...+248 °F)
(-40...+176 °F)
(-40...+248 °F)
(-40...+140 °F)
(+32...+212 °F)
1
2
3
4
5
6
7
Analog output range -20...+80 °C
for temperature
-20...+120 °C
-40...+80 °C
-40...+120 °C
-40...+60 °C
0...+100 °C
Units (local display metric
and serial interface) non-metric
Installation kit for
no
yes: for +80 °C cable
(+176 °F)
duct mounting
yes: for +120 °C cable (+248 °F)
Regaining option *) no regaining
(HUMICAP K)
regaining
(HUMICAP KC)
and sensor type
Manual language
No manual
English
German
French
Finnish
A
B
C
D
E
F
1
2
A
B
C
3
2
A
B
C
D
E
*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.
If the regaining option is chosen, the sensor must be protected either with a sintered filter or
with a PPS plastic grid with steel netting; the PPS plastic grid can not be used.
Please note that if mains power (115/230V) is selected regaining cannot be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.
TOTAL
QTY
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
HMP233 A
End customer:
1
A
0
A
2
A
A
1
2
A
1
A
3
B
Legacy configuration codes
Valid from 25th February 2003
HMP234 Humidity and Temperature Transmitter
With pressure tight high temperature probe
Industrial humidity and temperature transmitter
Transmitter
RH+T
RH+T+Td
type
RH+T+a+Tw+x
Display
Probe cable length
Power supply,
alarm output &
connectors
Using serial interface:
Serial interface
Sensor protection
Analog output
signals
(Ch1 and Ch2)
HMP234
1
A
PRICE
A
B
C
RH+T+Td+a+Tw+x+h
RH+T+h
no display
display on transmitter cover
2 m cable, +180 °C (+356 °F)
5 m cable, +180 °C (+356 °F)
10 m cable, +180 °C (+356 °F)
D
F
1
2
A
B
C
24 V, no connectors
115 V, no connectors
230 V, no connectors
24 V, + alarm output unit (no connectors)
24 V, shared connector for power supply and analog outputs
24 V, as above + alarm output unit not on connector
115 V, connector for analog outputs
230 V, connector for analog outputs
24 V, connector for RS232C
24 V, 2 connectors: RS232C and analog outputs+power supply
24 V, 2 connectors shared for power supply and RS485
0
1
2
3
4
5
6
7
8
9
9
RS 232C
RS 485/RS 422
current loop
sintered stainless steel filter (16452)
4...20 mA
0...20 mA
0...1 V
0...5 V
0...10 V
A
B
C
1
A
B
C
D
E
A
B
C
D
E
channel 1
channel 2
Parameters for the
analog outputs
(Ch1 and Ch2)
RH
T
Td
a
Tw
x
h
(0...100 %RH)
(range: see below)
(-40...+100 °C)
(0...600 g/m3)
(0...+100 °C)
(0...500 g/kg d.a.)
(-40...1500 kJ/kg)
Analog output range -20...+80 °C
for temperature
-20...+120 °C
-20...+180 °C
-40...+80 °C
-40...+120 °C
-40...+180 °C
Units (local display metric
and serial interface) non-metric
Regaining option *) no regaining
regaining
and sensor type
Manual language
No manual
English
German
French
Finnish
1
2
3
4
5
6
7
(-40...+212 °F)
(0...+262 gr/ft3)
(+32...+212 °F)
(0...3500 gr/lb d.a.)
(-17.2...644.9 Btu/lb)
channel 1
channel 2
1
2
3
4
5
6
7
(-4...+176 °F)
(-4...+248 °F)
(-4...+356 °F)
(-40...+176 °F)
(-40...+248 °F)
(-40...+356 °F)
A
B
C
D
E
F
1
2
A
(HUMICAP K)
(HUMICAP KC)
3
2
A
B
C
D
E
TOTAL
QTY
*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.
Please note that if mains power (115/230V) is selected regaining cannot be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.
TOTAL VALUE
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
HMP234 A
End customer:
1
A
0
A
1
A
A
1
2
A
1
A
3
B
Legacy configuration codes
Valid from 25th February 2003
HMP235 Humidity and Temperature Transmitter
With high temperature probe
Industrial humidity and temperature transmitter
Transmitter
RH+T
RH+T+Td
type
RH+T+a+Tw+x
Display
Probe cable length
Power supply,
alarm output &
connectors
Using serial interface:
Serial interface
Sensor protection
Analog output
signals
(Ch1 and Ch2)
Parameters for the
analog outputs
(If available in the
chosen transmitter
type)
(Ch1 and Ch2)
Analog output range
for temperature
Units (local display
and serial interface)
Installation kit
Regaining option *)
and sensor type
Manual language
HMP235
PRICE
A
B
C
RH+T+Td+a+Tw+x+h
RH+T+h
no display
display on transmitter cover
2 m cable, +180 °C
(+356 °F)
5 m cable, +180 °C
(+356 °F)
10 m cable, +180 °C
(+356 °F)
D
F
1
2
A
B
C
24 V, no connectors
115 V, no connectors
230 V, no connectors
24 V, + alarm output unit (no connectors)
24 V, shared connector for power supply and analog outputs
24 V, as above + alarm output unit not on connector
115 V, connector for analog outputs
230 V, connector for analog outputs
24 V, connector for RS232C
24 V, 2 connectors: RS232C and analog outputs+power supply
24 V, 2 connectors shared for power supply and RS485
0
1
2
3
4
5
6
7
8
9
9
RS 232C
RS 485/RS 422
current loop
sintered stainless steel filter (16452)
PPS plastic grid & stainless steel netting (16720HM)
4...20 mA
0...20 mA
0...1 V
0...5 V
0...10 V
channel 1
channel 2
RH
(0...100 %RH)
T
(range: see below)
Td
(-40...+100 °C)
(-40...+212 °F)
a
(0...600 g/m3)
(0...+262 gr/ft3)
Tw
(0...+100 °C)
(+32...+212 °F)
x
(0...500 g/kg d.a.)
(0...3500 gr/lb d.a.)
h
(-40...1500 kJ/kg)
(-17.2...644.9 Btu/lb)
channel 1
channel 2
-20...+180 °C
(-4...+356 °F)
0...+180 °C
(+32...+356 °F)
metric
non-metric
no installation kit
aluminium flange
steel flange
no regaining
(HUMICAP K)
regaining
(HUMICAP KC)
No manual
English
German
French
Finnish
A
B
C
1
2
A
B
C
D
E
A
B
C
D
E
1
2
3
4
5
6
7
1
2
3
4
5
6
7
A
B
1
2
A
B
C
3
2
A
B
C
D
E
TOTAL
*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.
QTY
If the regaining option is chosen, the sensor must be protected either with a sintered filter or
TOTAL VALUE
with a PPS plastic grid with steel netting; the PPS plastic grid can not be used.
Please note that if mains power (115/230V) is selected regaining cannot be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
HMP235 A
End customer:
1
A
0
A
1
A
A
1
2
A
1
A
3
B
Legacy configuration codes
Valid from 25th February 2003
HMP237 Humidity and Temperature Transmitter
With compact probe for demanding environments
Industrial humidity and temperature transmitter
Transmitter
RH+T
RH+T+Td
type
RH+T+a+Tw+x
Display
Probe cable length
Power supply,
alarm output &
connectors
Using serial interface:
HMP237
PRICE
A
B
C
RH+T+Td+a+Tw+x+h
RH+T+h
no display
display on transmitter cover
2 m cable, +180 °C (+356 °F)
5 m cable, +180 °C (+356 °F)
10 m cable, +180 °C (+356 °F)
D
F
1
2
A
B
C
24 V, no connectors
115 V, no connectors
230 V, no connectors
24 V, + alarm output unit (no connectors)
24 V, shared connector for power supply and analog outputs
24 V, as above + alarm output unit not on connector
115 V, connector for analog outputs
230 V, connector for analog outputs
24 V, connector for RS232C
24 V, 2 connectors: RS232C and analog outputs+power supply
24 V, 2 connectors shared for power supply and RS485
0
1
2
3
4
5
6
7
8
9
9
Serial interface
RS 232C
A
RS 485/RS 422
B
current loop
C
Sensor protection
sintered stainless steel filter (16452)
PPS plastic grid & stainless steel netting (16720HM)
Analog output
4...20 mA
signals
0...20 mA
(Ch1 and Ch2)
0...1 V
0...5 V
0...10 V
channel 1
channel 2
Parameters for the RH
(0...100 %RH)
analog outputs
T
(range: see below)
(If available in the
Td
(-40...+100 °C)
(-40...+212 °F)
chosen transmitter
a
(0...600 g/m3)
(0...+262 gr/ft3)
type)
Tw
(0...+100 °C)
(+32...+212 °F)
x
(0...500 g/kg d.a.)
(0...3500 gr/lb d.a.)
h
(-40...1500 kJ/kg)
(-17.2...644.9 Btu/lb)
(Ch1 and Ch2)
channel 1
channel 2
Analog output range -20...+80 °C
(-4...+176 °F)
for temperature
-20...+120 °C
(-4...+248 °F)
-20...+180 °C
(-4...+356 °F)
-40...+80 °C
(-40...+176 °F)
-40...+120 °C
(-40...+248 °F)
-40...+180 °C
(-40...+356 °F)
0...+100 °C
(+32...+212 °F)
Units (local display metric
and serial interface) non-metric
Installation kit
no
for duct mounting
Regaining option *) no regaining
(HUMICAP K)
regaining
(HUMICAP KC)
and sensor type
Manual language
No manual
English
German
French
Finnish
1
2
A
B
C
D
E
A
B
C
D
E
1
2
3
4
5
6
7
1
2
3
4
5
6
7
A
B
C
D
E
F
G
1
2
A
B
3
2
A
B
C
D
E
TOTAL
QTY
TOTAL VALUE
*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.
If the regaining option is chosen, the sensor must be protected either with a sintered filter or
with a PPS plastic grid with steel netting; the PPS plastic grid can not be used.
Please note that if mains power (115/230V) is selected regaining cannot be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
HMP237 A
End customer:
1
A
0
A
1
A
A
1
2
B
1
A
3
B
Legacy configuration codes
Valid from 25th of February 2003
HMP238 Humidity and Temperature Transmitter
With pressure tight high temperature probe for pipeline installations
Industrial humidity and temperature transmitter
Transmitter
RH+T
RH+T+Td
type
RH+T+a+Tw+x
Display
Probe cable length
Power supply,
alarm output &
connectors
Using serial interface:
HMP238
PRICE
1
A
B
C
RH+T+Td+a+Tw+x+h
RH+T+h
no display
display on transmitter cover
(+356 °F)
2 m cable, +180 °C
(+356 °F)
5 m cable, +180 °C
10 m cable, +180 °C
(+356 °F)
D
F
1
2
A
B
C
0
1
2
3
4
5
6
7
8
9
9
24 V, no connectors
115 V, no connectors
230 V, no connectors
24 V, + alarm output unit (no connectors)
24 V, shared connector for power supply and analog outputs
24 V, as above + alarm output unit not on connector
115 V, connector for analog outputs
230 V, connector for analog outputs
24 V, connector for RS232C
24 V, 2 connectors: RS232C and analog outputs+power supply
24 V, 2 connectors shared for power supply and RS485
Serial interface
RS 232C
RS 485/RS 422
current loop
sintered stainless steel filter (16452)
Sensor protection
Analog output
4...20 mA
signals
0...20 mA
(Ch1 and Ch2)
0...1 V
0...5 V
0...10 V
channel 1
channel 2
Parameters for the
RH
(0...100 %RH)
analog outputs
T
(range: see below)
(If available in the
Td
(-40...+100 °C)
(-40...+212 °F)
chosen transmitter
a
(0...600 g/m3)
(0...+262 gr/ft3)
type)
Tw
(0...+100 °C)
(+32...+212 °F)
x
(0...500 g/kg d.a.)
(0...3500 gr/lb d.a.)
h
(-40...1500 kJ/kg)
(-17.2...644.9 Btu/lb)
(Ch1 and Ch2)
channel 1
channel 2
Analog output range -20...+80 °C
(-4...+176 °F)
for temperature
-20...+120 °C
(-4...+248 °F)
-20...+180 °C
(-4...+356 °F)
-40...+80 °C
(-40...+176 °F)
-40...+120 °C
(-40...+248 °F)
-40...+180 °C
(-40...+356 °F)
Units (local display metric
and serial interface) non-metric
Installation kit
no installation kit
ball valve set for pipeline installations
Regaining option *) no regaining
(HUMICAP K)
regaining
(HUMICAP KC)
and sensor type
Manual language
No manual
English
German
French
Finnish
A
B
C
1
A
B
C
D
E
A
B
C
D
E
1
2
3
4
5
6
7
1
2
3
4
5
6
7
A
B
C
D
E
F
1
2
A
D
3
2
A
B
C
D
E
TOTAL
QTY
TOTAL VALUE
*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.
If the regaining option is chosen, the sensor must be protected either with a sintered filter or
with a PPS plastic grid with steel netting; the PPS plastic grid can not be used.
Please note that if mains power (115/230V) is selected regaining cannot be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
Example of order code with typical settings:
HMP235 A
End customer:
1
A
0
A
1
A
A
1
2
A
1
A
3
B