Safety Precautions
This installation manual indicates you to install the wired remote controller
which is connected to the indoor unit. For installation of other optional
accessories, see an appropriate installation manual.
WARNING
CAUTION
E-2
◆ Read carefully this installation manual before
installation and check whether the remote controller
is installed correctly after installation.
◆ Do not attempt to install or repair this wired remote
controller by yourself.
◆ This remote controller contains no user-serviceable
parts. Always consult authorized service personnel
for repairs.
◆ When moving, consult authorized service personnel
for disconnection and installation of the remote
controller.
◆ Ensure that the wall is strong enough to support the
weight of the remote controller.
◆ Must install the remote controller with rated power
supply.
◆ The remote controller must be installed according to
the national electrical rules by an installation specialist.
◆ When you want to disuse the remote controller,
consult authorized installation center.
◆ Do not use inflammable gases near the remote
controller.
◆ Do not install the remote controller in a location where
it will come into contact with the combustible gases,
machine oil, sulphide gas, etc.
◆ Avoid a location where acid/alkali solution or special
spray is used.
◆ Choose a location that is dry and sunny, but not
exposed to direct sunlight. Available temperature is
between 0°C and 39°C.
◆ Do not spill water into the wired remote controller.
◆ Do not give tensile strength to the cable to avoid
disconnection.
◆ Do not press buttons with a pointed thing.
◆ Do not connect the power cable to the control terminal.
◆ If the remote controller is installed in a hospital or other
special places, it should not affect other electronic
devices.
ENGLISH
Contents
◆ WIRED REMOTE CONTROLLER AND ACCESSORIES . . . . . . . 4
◆ DIVIDING THE COM1/COM2
■ Flowchart for dividing COM1/COM2 . . . . . . . . . . . . . . . . . . . . . . 5
■ The Diagram of COM1/COM2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
INSTALLING TO COM1(F1, F2)
◆ INSTALLING THE COMMUNICATION CABLE
■ Installing the Communication cable . . . . . . . . . . . . . . . . . . . . . . 7
■ Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
■ Setting up indoor unit PCB and Wired Remote
Controller Option Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
■ Examples of installing Wired Remote Controller . . . . . . . . . . . .10
■ The errors indicated on the Wired Remote Controller . . . . . . . .12
INSTALLING TO COM2(F3, F4)
◆ INSTALLING THE COMMUNICATION CABLE
■ Installing the Communication cable . . . . . . . . . . . . . . . . . . . . . .13
■ Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
■ Setting up indoor unit PCB and Wired Remote
Controller Option Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
■ The errors indicated on the Wired Remote Controller . . . . . . . .16
■ Examples of installing Wired Remote Controller . . . . . . . . . . . .17
■ The errors indicated on the GHP Wired Remote Controller . . .21
◆ ADDITIONAL FUNCTION OF THE WIRED REMOTE CONTROLLER
■ Assigning the indoor unit RMC with the
Wired Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
■ Canceling the indoor unit RMC assigned with the
Wired Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
E-3
Wired Remote Controller and Accessories
Accessories
The following accessories are supplied with the air conditioner.
➢
The number of each accessory is indicated in parentheses.
Cable-tie (2)
Communication
Cable clamp (5) M4x16 tapped Indoor Unit
Wire joint (1)
User’s
screw (7)
Power Drawing cable of the wired
manual (1)
remote controller (1)
DIP(1)
switch(SW03) on the PCB to the “OFF”
1 Adjust K1Cable
position.
CAUTION
◆ The wired remote controller must be installed by an
installation specialist.
◆ Before installing the wired remote controller, check
that you have turned off the main power.
◆ All cables should be installed according to the
national wiring rules and you must install it to the
wall not to be touched by users.
◆ Communication cable and power cable should be
installed separately.
(Connecting the power cable to communication
terminal will cause serious damage to the wired
remote controller. Please make sure that the power
cable is connected to the appropriate power terminal
to avoid serious damage.)
E-4
ENGLISH
Dividing the COM1/COM2
Flowchart for dividing COM1/COM2
Does the
indoor unit
support COM2(F3, F4)?
(Refer to the indoor unit
user's manual.)
No
Yes
Install the wired remote controller to
COM2. (Assign the DS01 switch of
the PCB of the wired remote
controller to SW2 OFF.)
Install the wired remote controller to
COM1. (Assign the DS01 switch of
the PCB of the wired remote
controller to SW2 ON.)
PCB of the indoor unit
Wired remote controller PCB
K1 : Adjust to OFF position.
S/W NO Switch ON Switch OFF
COM1
COM2
SW2
(F1, F2)
(F3, F4)
E-5
Dividing the COM1/COM2 (cont.)
The Diagram of COM1/COM2
COM1 Diagram
DVM Outdoor unit
COM1(F1, F2)
Indoor unit
MAIN RMC
MAIN RMC
MAIN RMC
Wired remote controller
Group control
COM2 Diagram
DVM PLUS Outdoor unit
COM1(F1, F2)
Indoor unit
COM2(F3, F4)
COM2(F3, F4)
Wired remote controller
Group control
E-6
ENGLISH
Installing to COM1(F1, F2)
Installing the Communication cable
◆ In case of 1-way cassette, connect the terminal BLOCK of the opening part of the
indoor unit with the main PCB of indoor unit using the indoor unit power drawing
cable as shown in the picture.
◆ The wired remote controller power cable is installed in all air conditioners except
1-way cassette.
Indoor
unit PCB
AC Power supply
Don’t confuse the color.
Red
Blue
White
Black
Communication cable of the
wired remote controller
COM1(F1, F2)
Power cable of the wired
remote controller
Red2P(2.5 pitch)
Red2P
(2.5 pitch)
Red
Blue
White
Black
White2P(2.5 pitch)
White2P
(2.5 pitch)
E-7
Installing to COM1(F1, F2) (cont.)
Installation
1
Open the wired remote controller by using 2 grooves on its
top.
2
Secure the rear cover of the wired remote controller on the
wall with 2 screws.
3 Connect each F1, F2, V1, V2, indoor unit terminal with
the wired remote controller terminal F1, F2, V1, V2.
◆ When connecting the communication cable and
the power cable, don’t confuse about each cable.
If the cables are connected improperly, the wired
remote controller will not work.
4
After checking the kind of outdoor unit, assign the DS01
switch SW2 of the indoor unit PCB to ON.
◆ If you set to COM2 and install it to COM1, ‘606’ of
error signs is displayed on the wired remote
controller.
SW1 SW2 SW3 SW4
DS01
SW5 SW6 SW7 SW8
DS02
Switch
No.
Switch ON
Switch OFF
SW1
Cooling Only
Cooling and Heating
SW2
COM2(F3, F4)
COM1(F1, F2)
SW3
°C
°F
SW4
The wired and
wireless remote
controller available
Can be used
wired remote controller
only
SW5
Refer to the chapter ‘Additional Function of the wired
remote controller’.
5 Reassemble the wired remote controller.
E-8
ENGLISH
Setting up indoor unit PCB and Wired
Remote Controller Option switches
Indoor unit PCB
◆ If you control the indoor unit with the wired remote
controller, adjust K1 of SW4 option switch of the
indoor unit PCB to ‘OFF’.
◆ If you install the indoor unit as shown in the picture,
can control it with the wired remote controller.
ADDRESS of the wired remote controller and RMC
ADDRESS of the indoor unit should be assigned as
the same.
RMC
SW4
◆ Therefore as the RMC ADDRESS is adjusted to
‘0’ in the picture, the indoor unit is controlled by
the wired remote controller which is adjusted to ‘0’.
Wired remote controller PCB
Indoor unit MAIN PCB switch
DS03
◆ Assign the RMC ADDRESS of the wired remote
controller same as the indoor unit to be controlled.
ADDRESS Switch
E-9
Installing to COM1(F1, F2) (cont.)
Examples of installing Wired Remote Controller
Individual control : Individual control of 3 indoor units with 3 wired remote controller.
Indoor unit PCB
SW4
DVM Outdoor unit
MAIN
ADDRESS
RCM
ADDRESS
Indoor unit
MAIN RMC
Wired remote controller
E-10
MAIN RMC
MAIN RMC
ENGLISH
Individual & Group control : Controlling 1 indoor unit of 3 indoor units with ADDRESS
‘0’ of the wired remote controller individually and controlling
the other 2 indoor units with ADDRESS ‘1’ of the wired
remote controller as a group.
Indoor unit PCB
SW4
DVM Outdoor unit
MAIN
ADDRESS
RCM
ADDRESS
Indoor unit
MAIN RMC
MAIN RMC
MAIN RMC
Wired remote controller
Group control
E-11
Installing to COM1(F1, F2) (cont.)
The errors indicated on the Wired Remote Controller
◆ The errors of outdoor unit, indoor unit and optional accessories are indicated on the
LCD.
◆ If the
is indicated, press the
display the error code.
button in front of the wired remote controller to
◆ In case of displaying same error of several indoor units, the front number is displayed first.
Display
Explanation
ER
EA
Indoor unit
Wired LCD communication error
ER
EB
Wired LCD
Indoor unit communication error
✽
ER
A✽
EVE IN sensor separation error of the indoor unit
✽
ER
B✽
EVE OUT sensor separation error of the indoor unit
✽
ER
C✽
Open error of electronic expansion valve in the outdoor unit
✽
ER
D✽
Close error of electronic expansion valve in the outdoor unit
✽
ER
F✽
EVE MID, EVE OUT sensor simultaneous separation
error of the indoor unit
ER
G1
SUB COOL sensor separation error of the outdoor unit
ER
G2
Refrigerant leak of outdoor unit / Loading Failure
ER
G3
COND MID sensor separation error of the outdoor unit
✽
ER
O✽
Floating S/W error of the indoor unit
✽
ER
Q✽
Room sensor OPEN/SHORT error of the indoor unit
✽
ER
R✽
EVE IN sensor OPEN/SHORT error of the indoor unit
✽
ER
Y✽
EVE OUT sensor OPEN/SHORT error of the indoor unit
✽
ER
T✽
EEPROM inferior error
✽
ER
U✽
EEPROM option error
✽
ER
V✽
Fan motor moving is abnormal
Indoor unit ADDRESS : ✽
E-12
Remark
ENGLISH
Installing to COM2(F3, F4)
Installing the Communication cable
◆ If the indoor unit is a 1-way cassette, connect the indoor unit PCB to the terminal
block within the indoor unit using the power cable of the wired remote controller
as shown in the first picture.
◆ All other indoor units except the 1-way cassette have the power cable installed.
Connector type cable connection
Indoor
unit PCB
AC Power supply
Don’t confuse the color.
White
Black
F3
Red
F4
Blue
White 2P(2.5 pitch)
White 2P
(2.5 pitch)
White
Power cable of the wired
remote controller
Black
Red
Communication cable of the
wired remote controller
COM2(F3, F4)
Blue
Blue 2P(2.5 pitch)
Blue 2P
(2.5 pitch)
Terminal type cable connection
Indoor
unit PCB
AC Power supply
Don’t confuse the color.
White
Black
Red
Blue
White 2P(2.5 pitch)
White 2P
(2.5 pitch)
Blue 2P(2.5 pitch)
Blue 2P
(2.5 pitch)
White
Power cable of the wired
remote controller
Black
Red
Communication cable of the
wired remote controller
COM2(F3, F4)
Blue
E-13
Installing to COM2(F3, F4) (cont.)
Installation
1
Open the wired remote controller using the 2 grooves
on the top.
2
Secure the rear cover of the wired remote controller on
the wall with 2 screws.
3 Connect V1, V2 with the wired remote controller
terminal V1, V2.
4 After checking the kind of outdoor unit, assign the DS01
switch SW2 of the indoor unit PCB to ‘OFF’.
◆ If you set to COM1 and install it to COM2, ‘EA’
communication error sign is displayed on the
wired remote controller.
F3
F4
Housing
Indoor unit
Cables
(purchased
on the spot)
Wired
remote
controller
Indoor unit
Cables
(purchased
on the spot)
E-14
5
Connect the indoor unit housing with the wired remote
controller housing or connect the F3, F4 terminal of the
wired remote controller to the F3, F4 terminal of the
terminal block depending on the indoor unit type.
6
Reassemble the wired remote controller.
Tighten the
cable with the
wire joint
(accessories)
tightly.
Wired
remote
controller
CAUTION
◆ Install the wired remote controller of GHP in the same
way.
◆ The wired remote controller must be installed by an
installation specialist.
◆ Before installing the wired remote controller, check
that you have turned off the main power.
◆ All cables should be installed according to the national
wiring rules and you must install it to the wall not to
be touched by users.
◆ Communication cable and power cable should be
installed separately. (The wired remote controller can
be operated abnormally due to electric trouble.)
ENGLISH
Setting up indoor unit PCB and
Wired Remote Controller Option Switches
Indoor unit PCB
DS01
◆ Adjust the K1 switch(SW4) - option switch of the
indoor unit PCB - to ‘OFF’, which is to be controlled
by the wired remote controller. Adjusting of the K1
switch(SW4) means the use of wired remote
controller.
DS03
DS02
The back of the wired remote
controller
Wired remote controller PCB
◆ Connect the wired remote controller with the indoor
unit to be controlled. (You don’t have to assign the
ADDRESS.)
◆ Refer to the following option table to assign the
switch according to the user’s situation.
Switch
No.
Switch ON
Switch OFF
DS03
SW1
Cooling Only
Cooling and Heating
SW2
COM2(F3, F4)
COM1(F1, F2)
SW3
°C
°F
SW4
Wired and
wireless remote
controller available
Can be used
wired remote controller
only
SW5
Refer to the chapter
‘Additional Function of the
wired remote controller’.
ADDRESS Switch
E-15
Installing to COM2(F3, F4) (cont.)
The errors indicated on the Wired
Remote Controller
◆ The error of outdoor unit, indoor unit and optional
accessories is indicated on the LCD.
◆ If the
is indicated, press the
button in front of
the wired remote controller to display the error code.
◆ In case of displaying same error of several indoor units,
the front number is displayed first.
N o t e ◆ 2-remote controller controls the indoor unit individually
connected with the COM2 regardless of setting the
indoor unit RMC ADDRESS.
Display
Explanation
Remark
Wired remote controller
Indoor unit communication error
Master wired remote controller
Slave wired remote controller
COM1/COM2 cross-installed error
E-16
When using
2-remote control
ENGLISH
Examples of installing Wired Remote Controller
Individual control : Individual control of 1 indoor unit wired remote controller
Wired remote controller PCB
Indoor unit PCB
Outdoor unit
COM1
COM1
Indoor unit
COM2
COM2
COM2
Wired remote controller
Don’t change the default settings of the wired remote controller.
DS03
N o t e ◆ Don’t change the DS03 switch of wired remote controller PCB from
the default settings when the outdoor unit is shipped from the factory.
(If you change the default settings, the communication error is
displayed and the wired remote control doesn’t operate normally.)
◆ The wired remote controller controls the indoor unit individually
connected with the COM2 regardless of the set RMC ADDRESS of
the indoor unit.
E-17
Installing to COM2(F3, F4) (cont.)
Group control : Controlling more than 2 indoor units with a wired remote controller
Wired remote controller PCB
Indoor unit PCB
Outdoor unit
COM1
COM1
COM1
COM2
COM2
Indoor unit
Wired remote controller
E-18
ENGLISH
Group control : The outdoor unit controls 2 different indoor units simultaneously with
a wired remote controller. (Except the GHP model)
Wired remote controller PCB
Indoor unit PCB
Outdoor unit
Indoor unit
Outdoor unit
Wired remote controller
Indoor unit
N o t e ◆ The wired remote controller controls the indoor units together connected with
the COM2 regardless of setting the indoor unit RMC ADDRESS.
E-19
Installing to COM2(F3, F4) (cont.)
2-remote controller control : 2-remote controller means 2 wired remote controllers
control 1 indoor unit.
Set the DS03 switch of the wired remote controller
PCB as shown in the picture.
Wired remote controller PCB
Outdoor unit
COM1
Indoor unit
COM2
Wired remote
controller(Master)
Wired remote
controller(Slave)
DS03
(Set to ‘0’)
E-20
DS03
(Set to ‘1’)
Indoor unit PCB
ENGLISH
The errors indicated on the GHP
Wired Remote Controller
◆ The error of outdoor unit, indoor unit and optional
accessories is indicated on the LCD.
◆ If the
is indicated, press the
button in front of
the wired remote controller to display the error code.
◆ In case of displaying same error of several indoor units,
the front number is displayed first.
Display
Remote
controller
Outdoor unit PCB
code
Explanation
Trouble
Sub code
Examination
frquency
(times)
#
Communication error
between the wired
remote controller and
indoor unit
After communication between the wired
remote controller and indoor unit more than
once and communication cuts off for
2 minutes continuously
1
#
The same ADDRESS
errors
The same ADDRESS of the indoor unit
1
0
Indoor and outdoor unit No outdoor unit which is correspond to the
connection error
indoor unit
0
- Communication error after communication
between wired remote controller and indoor
unit more than once
- Error is displayed from the indoor unit during
operation
Indoor and outdoor unit
Communication error after communication
communication error
between wired remote controller and indoor
unit more than once
- Error detected from the outdoor unit
(60 seconds during operation,
150 seconds during off)
The self - transmission data is not received
0
Communication error
After communication between wired remote
between the indoor unit controller and centralized controller more than
and centralized
once and cut off for 2 minutes continuously
controller
1
1
1
1
1
# is indicated according to the unit ADDRESS (0~F).
E-21
Installing to COM2(F3, F4) (cont.)
Display
Remote
controller
Outdoor unit PCB
code
Explanation
Sub code
#
Indoor unit fan motor
error
#
Indoor unit EEPROM
error
Examination
frquency
(times)
The fan doesn’t operate in set speed or is
stopped
1
- Record of the data is forbidden during power
failure
1
- Discord between a record data and call data
#
Manual ADDRESS of
the indoor unit is
mixed up
Communication discord with the indoor unit
1
0
Manual ADDRESS of
the outdoor unit is
mixed up
Communication discord with the outdoor unit
1
0
EEPROM error
EEPROM error
1
0
Indoor unit connection
exceeds
More than 16 indoor unit is connected with
the outdoor unit
1
0
Discord between
indoor and outdoor unit Discord between indoor and outdoor unit
0
Abnormal ventilation
temperature
Ventilation temperature is over 660°C during
engine operation for more than 30 seconds
1
0
Communication error
between indoor and
outdoor unit
After communication between indoor and
outdoor unit more than one time and the
communication among indoor units is cut
off for 2 minutes continuously
1
Induction temperature sensor of the
compressor 1: detects lower than
-39°C for 1 minute continuously
1
0
1
2
3
Induction temperature
sensor of the compressor
is disconnected
Induction temperature sensor of the
compressor 2: detects lower than
-39°C for 1 minute continuously
Induction
temperature sensor
of the compressor
(SHORT)
# is indicated according to the unit ADDRESS (0~F).
E-22
Trouble
1
1
Induction temperature sensor of the
compressor 1: detects higher than
90°C for 1 minute continuously
1
Induction temperature sensor of the
compressor 2: detects higher than
90°C for 1 minute continuously
1
ENGLISH
Display
Remote
controller
Outdoor unit PCB
code
Explanation
Trouble
Sub code
Examination
frquency
(times)
0
Starter error
Detects higher than 5V for 3 seconds of the
starter voltage during off
2
(15 minutes)
0
Outdoor air
temperature sensor is
disconnected
Detects the outdoor temperature lower than
-39°C for 1 minute continuously
1
1
Outdoor air
temperature sensor
(SHORT)
Detects the outdoor temperature higher than
90°C for 1 minute continuously
1
2
Outdoor air
temperature sensor
is abnormal
Detects outdoor air temperature sensor
disconnection or short circuit for 2 minutes
continuously
1
Accumulator outlet temperature sensor 1
is disconnected
1
Accumulator outlet temperature sensor 2
is disconnected
1
Accumulator outlet temperature sensor 1
(SHORT)
1
0
1
2
Accumulator outlet
temperature sensor
1 is disconnected
Accumulator outlet
temperature sensor
2 is disconnected
Accumulator outlet
temperature sensor 1
(SHORT)
3
Accumulator outlet
temperature sensor 2
(SHORT)
Accumulator outlet temperature sensor 2
(SHORT)
1
4
Accumulator outlet
temperature sensor
1 is safe
Accumulator outlet temperature sensor 1
is safe
1
5
Accumulator outlet
temperature sensor
is safe
Accumulator outlet temperature sensor
is safe
1
0
Detects outdoor heat exchanger temperature
Outdoor heat
exchanger temperature sensor lower than -39°C for 1 minutes
sensor is disconnected continuously
1
2
Detects outdoor heat exchanger temperature
Outdoor heat
exchanger temperature sensor higher than 90°C for 1 minutes
sensor (SHORT)
continuously
1
0
Engine water
temperature sensor is
disconnected
Detects engine water temperature sensor
during engine operation lower than 0°C for
3 minutes continuously
2
(15 minutes)
# is indicated according to the unit ADDRESS (0~F).
E-23
Installing to COM2(F3, F4) (cont.)
Display
Remote
controller
Outdoor unit PCB
code
Explanation
Trouble
Sub code
0
0
1
6
8
Engine oil pressure
switch is disconnected
Engine room
temperature sensor is
disconnected
Engine room
temperature sensor
(SHORT)
- Before turning the starter ON, detects
engine oil pressure switch OFF for
5 seconds continuously
- After detecting first 2 times, operate engine
for 3 seconds and stops for 60 seconds
- Stops operating after detecting 3 times
1
Detects engine room temperature lower
than -30°C for 1 minutes continuously
1
Detects engine room temperature higher than
90°C for 1 minutes continuously
1
Detects ventilation temperature lower than
Ventilation temperature 250°C for 4 minutes continuously when
sensor is disconnected operating more than 1 compressor during
engine operation
Detects disconnection or short circuit of
Engine room
room temperature sensor for 2 minutes
temperature sensor
continuously
error
- Stops when the high pressure more than
2.9Mpa refrigerant is abnormal if the
compressor turns on
0
High pressure sensor
error
1
Examination
frquency
(times)
1
1
1
- Detects high pressure more than 3.2Mpa
when operating of next term
- Stops for 5 seconds when the high
pressure lower than 0.1Mpa when the
compressor turns on
1
- Detects high pressure lower than
0.1Mpa when operating of next term
1
4
Shortage of the
number of engine
rotations
After turning the starter on, rotation pulse
is less than 24
Engine rotations
control error
15 seconds after connecting with the
compressor, one of the following error is
detected
- Detects the engine rotation is lower than
1000RPM for 60 seconds continuously
- Detects the engine rotation is lower than
800RPM for 10 seconds continuously
# is indicated according to the unit ADDRESS (0~F).
E-24
2
(15 minutes)
3
(15 minutes)
ENGLISH
Display
Remote
controller
Outdoor unit PCB
code
Explanation
Trouble
Sub code
Examination
frquency
(times)
Engine rotations
control error
- The engine rotation frequency detects that
ordered rotation frequency that is lower than
±300RPM for 60 seconds continuously
3
(15 minutes)
6
Engine rotations
hunting error
15 seconds after connecting with the
compressor, one of the following error is
detected
- Detects the engine rotation is lower than
1000RPM for 60 seconds continuously
- Detects the engine rotation is lower than
800RPM for 10 seconds continuously
- The engine rotation frequency detects that
ordered rotation frequency that is lower than
±300RPM for 60 seconds continuously
3
(15 minutes)
7
Electronic gas valve
error
0
Engine stop
1
Low voltage of lighter
2
Detects the voltage of lighter lower than
Detection circuit of
voltage is disconnected 0.5V for 1 minute continuously
3
High voltage of lighter
0
Detects OFF of the high pressure switch for
High pressure switch is 3 minutes continuously if you stop operating
or during initial operation
disconnected
(Detects only when the transmitter is ON)
0
1
4
5
Continuous output of gas valve 1 or 2 for 30
seconds continuously except for the timer of
gas valve operation
Detects the engine rotation frequency is lower
4
than 650RPM for 1 second continuously
(15 minutes)
Detects the voltage of lighter lower than
9V for 1 minute continuously
Detects the voltage of lighter higher than
17V for 30 seconds continuously
Detects the outlet temperature 1 lower than
5°C when the compressor 1 is on for
- Discharge temperature
10 minutes continuously
of the compressor is
Detects the outlet temperature 2 lower than
not risen
5°C when the compressor 2 is on for
10 minutes continuously
Detects the outlet temperature 3 lower than
5°C when the compressor 3 is on for
- Discharge temperature 10 minutes continuously
of the compressor
Detects the outlet temperature 4 lower than
(SHORT)
5°C when the compressor 4 is on for
10 minutes continuously
3
(15 minutes)
1
1
1
2
(15 minutes)
2
(15 minutes)
2
(15 minutes)
2
(15 minutes)
# is indicated according to the unit ADDRESS (0~F).
E-25
Installing to COM2(F3, F4) (cont.)
Display
Remote
controller
Outdoor unit PCB
code
Explanation
Sub code
0
Engine water
temperature is
overheated
1
Engine water
temperature
sensor SHORT
2
Shortage of cooling
water of the engine
0
Engine oil pressure
error
0
Engine rotates too
often
1
Examination
frquency
(times)
Detects the engine water temperature for
2
operating higher than 105°C for 10 seconds
continuously (reset lower than 90°C available) (15 minutes)
Detects the engine water temperature higher
than 120°C for 1 minutes continuously
1
(reset lower than 120°C available)
Detects that the cooling water of the engine is
1
overheated higher than 90°C for 2 and a half
minutes after stop
Detects the engine oil pressure switch ON
for 3 seconds continuously after it passes
10 seconds after operating engine
2
(15 minutes)
Detects the engine operation higher than
3,500RPM for longer than 1 second
continuously
3
(15 minutes)
Detects the engine operation higher than
2,600RPM for longer than 10 second
continuously
3
(15 minutes)
0
Engine operation
failure
The number of engine rotations less than
700RPM is not detected 0.8 seconds after
turning the starter, for gas valve 2 is OFF
4
3
Engine MICOM
communication error
Engine MICOM communication error
4
4
0
0
Engine program record Engine program record error
4
error
- Detects the high pressure switch OFF for
3 seconds continuously when the
3
compressor is ON
High pressure of
(15 minutes)
refrigerant error
- Detects the high pressure higher than
2.9Mpa for 5 seconds continuously when the
compressor is ON
Induction temperature
of the compressor is
overrisen
# is indicated according to the unit ADDRESS (0~F).
E-26
Trouble
Detects when the compressor is turned ON,
the higher temperature from the temperature
range that the inlet sensor sensed in the
connection parts of the compressor over
60°C for 10 minutes continuously
1
ENGLISH
Display
Remote
controller
Outdoor unit PCB
code
Explanation
Trouble
Sub code
Examination
frquency
(times)
0
Low pressure of
refrigerant error
Detects the low pressure switch OFF for
3 seconds continuously when the
compressor is ON
2
Low pressure switch is
disconnected
Detects low pressure switch OFF for
3 minutes continuously when stops for
operating or when oil temperature is secured
1
5
Shortage of refrigerant
Detects high pressure switch(higher than
0.15Mpa) or low pressure switch OFF (reset
available when high pressure switch is higher
than 0.15Mpa or low pressure switch is ON)
1
0
Detects temperature sensor of the connection
side of the compressor(select the highest
Discharge temperature when more than 1 compressor) higher than
2
of the compressor is
(15 minutes)
120°C for 3 minutes continuously
overrisen
(reset available when all of the 4 detected
temperature is lower than 120°C)
2
3
6
7
7
Detects the compressor temperature
1 higher than 120°C for 1 minute continuously
(reset available when the temperature is lower
than 120°C)
Detects the compressor temperature
2 higher than 120°C for 1 minute continuously
(reset available when the temperature is lower
Discharge temperature than 120°C)
of the compressor
Detects the compressor temperature
(SHORT)
3 higher than 120°C for 1 minute continuously
(reset available when the temperature is lower
than 120°C)
Detects the compressor temperature
4 higher than 120°C for 1 minute continuously
(reset available when the temperature is lower
than 120°C)
The air conditioner
cools and heats
simultaneously
The air conditioner cools and heats
simultaneously
2
(15 minutes)
1
1
1
1
1
# is indicated according to the unit ADDRESS (0~F).
E-27
Additional Function of the Wired Remote Controller
When using automatic ADDRESS of DVM PLUS, assign
MAIN ADDRESS to the indoor and outdoor unit.
The RMC is not assigned to the indoor unit. If you want to
control the air conditioner with the centralized controller,
you should operate the RMC switch of the indoor unit manually.
You can also assign the RMC using wired remote controller
without operating manually. (Only in COM2 available)
Assigning the indoor unit RMC with
the Wired Remote Controller
◆ You can use this function to control the indoor unit in
the centralized controller.
◆ It means that you assign the RMC with the wired remote
controller without operating the RMC switch manually.
S/W NO.
SW5
E-28
Switch OFF
Switch ON
Assign the the indoor Cancel the indoor unit
unit RMC with the
RMC assigned with the
wired remote controller wired remote controller
ENGLISH
1
Set SW5 of DS02 switch on the wired remote controller
PCB to ‘OFF’.
Wired remote controller PCB
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
DS01
DS02
Set the indoor unit PCB
2
Press the
button and
button in front of the
wired remote control simultaneously for more than
5 seconds.
3 Wired remote controller LCD displays as shown in
the picture and changes to the ‘Indoor unit group
ADDRESS setting mode’.
Wired remote controller LCD
Group ADDRESS
(RMC) display
Indoor unit Main ADDRESS display
E-29
Additional Function of the Wired Remote Controller (cont.)
Initial display
◆
is displayed if the group has never been set.
If the group is set, the LCD receives the current indoor
unit ADDRESS(main address) and group ADDRESS
(RMC) from the indoor unit and displays them.
Changing of group ADDRESS (RMC)
◆ Press the
button to select the required group
ADDRESS. Then, the group ADDRESS display flickers
and changes.
Setting the group ADDRESS
◆ Press the
button once to set the selected group
ADDRESS with the ‘beep’ sound.
Quit
◆ Press the
button again to quit the setting mode and
enter the operation mode.
If you press the
button in the mode except the
‘Canceling the group ADDRESS’, quit the ‘Setting the
RMC switch group ADDRESS mode’.
CAUTION
◆ When assigning the RMC, the wired remote
controller of each indoor unit should be installed
one to one.
◆ If you assign the RMC to the indoor unit with the
wired remote controller, the indoor unit is
controlled by the RMC(assigned with the wired
remote controller) in the centralized controller
even if the RMC is set to the indoor unit PCB
manually.
E-30
ENGLISH
Canceling the indoor unit RMC assigned
with the Wired Remote Controller
1
Set SW5 of DS02 switch on the wired remote
controller PCB to ‘ON’.
Wired remote controller PCB
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
DS01
2
DS02
Press the
button and
button in front of the
wired remote controller simultaneously for more than
5 seconds.
3 Wired remote controller LCD displays as shown in
the picture and changes to the ‘Indoor unit group
ADDRESS setting mode’.
Wired remote controller LCD
Group ADDRESS
(RMC) display
Indoor unit Main ADDRESS display
E-31
Additional Function of the Wired Remote Controller (cont.)
Initial display
◆ If the group has never been set, the LCD receives the
RMC ADDRESS which is set to the indoor unit and
displays them.
Setting the RMC switch
◆ Press the
button once to control the indoor unit with
the set RMC switch ADDRESS with the ‘beep’ sound.
Quit
◆ Press the
button again to quit the setting mode and
enter the operation mode.
Wired remote controller LCD
If you set the
PCB RMC
switch to ‘3’
Example of the display
E-32
If you press the
button in the mode except the
‘Setting the RMC switch’, quit the ‘Canceling the
group ADDRESS mode’.
ENGLISH
Memo
E-33
THIS AIR CONDITIONER IS MANUFACTURED BY:
ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:
CE CLIMATISEUR EST FABRIQUE PAR:
QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA:
ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR:
DIESE KLIMAANLAGE IST FABRIZIERT VON:
AYTH H ™Y™KEYH KATA™KEYA™THKE A¶O:
ùíéí äéçÑàñàéçÖê àáÉéíéÇãÖç îàêåéâ:
ELECTRONICS
Printed in Korea