PCRAU0644A
Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the
world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a
particular country. Prior to purchase, please therefore confirm with your local authorised importer,
distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for
use, in the region where the product will be used. This statement does not purport to exclude, restrict
or modify the application of any local legislation.
Warning
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
The Comfort and Luxury You D eserve
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
JMI-0107
JQA-1452
Daikin Australia
Pty Limited (ISO 9001)
QEC 23256 31 May 2006
About ISO 9001
ISO 9001 is a plant certification
system defined by the International
Organization for Standardization (ISO)
relating to quality assurance. ISO
9001 certification covers quality
assurance aspects related to the
“ design, development, manufacture,
installation, and supplementary
service” of products manufactured at
Daikin Australia
Pty Limited (ISO 14001)
CEM20437 13 November 2006
Dealer
About ISO 14001
ISO 14001 is the standard defined by the
International Organization for
Standardization (ISO) relating to
environmental management systems. Our
group has been acknowledged by an
internationally accredited compliance
organisation as having an appropriate
programme of environmental protection
procedures and activities to meet the
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
c All rights reserved
Printed in Japan 06/07/005 DN
Specifications, designs and other content appearing in this brochure are current as of June 2007 but subject to change without notice.
Multi-Split Type Air Conditioners E series
With DC Inverter and Swing Compressor
Cooling Only & Heat Pump [50 Hz]
Air condition your entire home
with a single outdoor unit.
Contents
If you would like your conditioners
to match your personal dé
c or…
If you wish to make more effective use
of the space on your balcony…
If you want your family to be
comfortable
Concepts
3
Main features
5
Product lineup
9
Functions
19
Specifications
23
Options
26
Capacity tables
27
Super Multi N X is the knowledgeable choice.
The D aikin Super Multi N X lets you build a highly efficient multi room air
conditioning system by connecting up to four indoor units to a single outdoor unit.
The series includes a wide variety of indoor units, so it is easy to select a model that
blends in unobtrusively and allows you to create a dé
c or that matches your personality.
A single compact outdoor unit allows you to make more efficient use of available
space in the installation location, such as a balcony. The individual indoor units in
different rooms—the living room, study, and bedrooms, for example—can be controlled
independently to match your family’ s lifestyle. Super Multi N X makes your home
1
2
Concepts
Concepts
Key concepts for Super Multi N X
Enjoy the comfort and luxury of your dreams.
I n1969, Daikindevelopedthefirst multi roomair conditioningsysteminJapanthat
neededjust oneoutdoor unit. Over theensuing35years, Daikinhas built anenviable
reputationwith theconstant progress of its technology. Super Multi N X requires only a
singleoutdoor unit tomaintainpleasant comfort inuptofour rooms. Whereoutdoor unit
installationspaceis limited, it is theideal choice. A ir conditioner settings for each room
canbecontrolledindividually tosuit thepreferenceof each person. Whileoptimising
personal comfort, Super Multi N X uses DC inverter technology toreduceenergy waste.
4MK(X)S series
3MK(X)S series
New
Design
New
Design
The D C motor, swing compressor and other
advanced technologies make for energyefficient operation that achieves high CO Ps.
The quiet operation mode helps create a more
pleasant living environment. D C inverter
power control provides comfortable
Up to 4 indoor units can be connected.
The wide range of indoor unit options
provides ample choice. A single compact
outdoor unit reduces installation space
requirements, while long maximum piping
lengths provide flexibility for connections.
Up to 3 indoor units can be connected.
The individual indoor units in different rooms
can be controlled independently. The priorityroom setting function lets you specify a room
to receive preference in air conditioning
Connect 4 indoor units to a single outdoor unit
3
4
Main features
ntelligent
technologies
Main features
High energy efficiency through advanced
Convenient features to realise your
technologies delivers high COP.
ideal environment
Quiet operation
High energy efficiency for high COP
Indoor unit
3.79
COP during cooling operation (4MXS80EVMA)
COP during heating operation (4MXS80EVMA)
A quiet indoor unit is important for your personal comfort. SUPER
MULTI NX offers the quiet sound level of 22 dB during Indoor Unit
Quiet Operation of the FTXS20/25 during cooling operation.
4.59
3
22 dB is so quiet you can even hear whispers
Rustling of leaves
What is COP?
COP =
An air conditioner's COP (coefficient of performance) indicates how
efficiently it uses energy. A high COP means high energy efficiency.
Capacity (kW)
Power consumption (kW)
20
2
80
Conventional
DC motor
More than 20%
70
The reluctance DC motor employs
neodymium magnets. These magnets
are approximately 10 times stronger
than ferrite magnets.
0
30
Small load
Low capacity
60
90
120
Large load
High capacity
Neodymium magnet
Swing bush
Quiet office
A quiet outdoor unit is essential for your comfort and peace in your neighbourhood. SUPER MULTI NX
achieves a quiet sound level of 43 dB during Outdoor Unit Quiet Operation or Night Quiet Mode of the
3MXS52 during cooling operation. The minimum outdoor unit sound level is 39 dB.*
* Achievable when:
1. A single 2.0 or 2.5 kW class indoor unit is operating.
2. Indoor Unit Quiet Operation is selected for all indoor units in operation.
3. Outdoor Unit Quiet Operation is selected.
Ferrite magnet
DC inverter power control uses its
full capacity at startup to cool/warm
quickly. As soon as the set
temperature is reached, it carefully
adjusts current frequency to
prevent temperature fluctuation and
energy loss.
Refrigerant gas
Temp.
During cooling operation
Power
factor
Time
Too cool
Starts
DC inverter power control gives you greater comfort
Wide operation range
Inverter
efficiency
DC inverter type
Set temp.
Energy efficiency is increased by reducing
operational friction and refrigerant gas leakage.
Converter
efficiency
Non-inverter type
Not cool
Integral piston of blade and roller
Power supply
3 PAM control
(dB)
Comfortable temperature control
Rotational speed (rps)
2 Swing compressor
Pulse Amplitude Modulation (PAM) control
reduces energy loss by controlling the amount
of switching on/off of the converter.
50
Note: Capacity may decrease when quiet functions are selected.
AC motor
50
The swing compressor decreases friction
and vibration and also prevents the
leakage of refrigerant gas
during compression.
This gives much quieter
and more efficient
operation.
40
60
POWER
Motor efficiency (%)
Neodymium magnet
Reluctance DC Motor
30
Outdoor unit
Daikin energy-saving technologies
90
Quiet library
Midnight in the suburbs
1
The reluctance DC motor is much more
efficient than conventional AC and DC
motors. Its advanced design has
improved low-capacity
operation by more
than 20%.
22 dB
Note: Capacity may decrease when quiet functions are selected.
* During rated capacity operation of 4 indoor units
(2.0 + 2.5 + 5.0 + 5.0 kW class).
1 Reluctance DC motor
deal
environment
Even during a cold season, a crowded party or a sudden change in the
indoor temperature can leave a room overheated. With SUPER MULTI NX,
cooling operation is possible even during lower outdoor temperatures.
Note: This information is available for heat pump type.
50
40
30
Outdoor
20
temp.
10
0
Loss
Loss
4MXS80E
Heat pump type
Cooling
46
CDB
Heating
15.5
CWB
-10
-20
5
6
Main features
Main features
Wide array of choices to match
your interior
nterior &
exterior
flexibility
Individual control for each room to match
your family’s lifestyle
Preferential air conditioning
Stylish indoor units for elegant interiors
ndividual
control
Initial setting required during installation
Priority-Room Setting delivers priority capacity to a prioritised room when using multi-split air conditioners.
After a priority room is selected, it receives preferential air-conditioning plus priority control over the 3 functions below.
1
Priority setting with Inverter Powerful Operation
When Inverter Powerful Operation is selected in the priority room, the indoor unit capacity in the priority room is
increased by shifting capacity from units in other rooms. After 20 minutes, all units automatically return to their
original settings.
Note: Capacity in other rooms may decrease slightly.
Room
B
Living
room
The stylish flat panel design of the wallmounted type provides an excellent
match for interiors.
The compact and simple design blends in with any
type of room.
Only 240 mm is required above the
ceiling for installation.
Compact outdoor units for a less obtrusive exterior look
Priority
room
2
Priority
room
3
Priority setting with Outdoor Unit Quiet Operation
Priority-Room Setting also allows Outdoor Unit Quiet Operation to be selected by one command* from the
priority room.
* If Priority-Room Setting has not been set, the Outdoor Unit Quiet Operation button must be pushed on the
wireless remote controller of all indoor units operating at that time.
Long piping lengths for installation flexibility
Convenient remote controllers
The ample maximum piping length of 70 m permits
more freedom in the placement of air conditioner units
and facilitates the optimisation of interior space.
A variety of convenient controller systems permit individual control of
settings such as temperature, airflow volume, and operation duration.
Total
For each room
Room
C
Priority setting with operation mode
3MKS58
3MKS75
4MKS90
3MXS52
3MXS68
4MXS80
50 m
60 m
70 m
25 m
Wireless remote
controller
7
Room
C
Note: Operation mode can not be changed from other rooms.
Needs just one outdoor unit
—keep your home exterior beautiful!
Max.
piping length
Room
B
Living
room
The operation mode (cooling/heating) of the indoor unit in the priority room is given preference. When the
operation modes of the units in other rooms are different from the unit in the priority room, the units in the other
rooms wait on standby.
The system requires only a single
outdoor unit. The compact design
provides installation flexibility and
takes up less space, for a less
obtrusive exterior look.
Model name
Room
A
Power Up!
Room
A
Wired remote
controller
(option)
5-room centralised
controller
(option)
Central remote controller
(option)
Unified on/off
controller
(option)
8
Product lineup
Product lineup
A wide range of models to choose from that deliver excellent comfort and
convenience
An array of indoor unit models with innovative and attractive designs make
it easy to find the ideal match for each room in your home.
Outdoor units
Model
Model name
Capacity class
Max. piping length
Max. height difference
3MKS58EVMA
5.8 kW
50 m
15 m
3MKS75EVMA
7.5 kW
60 m
15 m
3MXS52EVMA
5.2 kW
50 m
15 m
3MXS68EVMA
6.8 kW
60 m
15 m
Cooling only
4MKS90EVMA
9.0 kW
70 m
15 m
Heat pump
4MXS80EVMA
8.0 kW
70 m
15 m
Connectable to up to 3 indoor units
Cooling only
Heat pump
Connectable to up to 4 indoor units
Wall-mounted type
An attractive match for large rooms with refined interiors is provided
by the stylish flat panel design.
Indoor units
Model
2.0 kW
2.5 kW
3.5 kW
Cooling only
FTKS20DVMA
FTKS25EVMA
FTKS35EVMA
Heat pump
FTXS20DVMA
FTXS25EVMA
FTXS35EVMA
Capacity class
Wall-mounted type
5.0 kW
6.0 kW
7.1 kW
Floor-standing type
Unobtrusive and convenient with a floor-standing compact design.
Cooling only
FTKS50FVMA
FTKS60FVMA
FTKS71FVMA
Heat pump
FTXS50FVMA
FTXS60FVMA
FTXS71FVMA
Duct-connected type
700 mm width
900/1,100 mm width
Cooling only
CDKS25EAVMA CDKS35EAVMA
Heat pump
CDXS25EAVMA CDXS35EAVMA
Cooling only
CDKS25CVMA
CDKS35CVMA
CDKS50CVMA
CDKS60CVMA
Heat pump
FDXS25CVMA
FDXS35CVMA
FDXS50CVMA
FDXS60CVMA
Heat pump
FVXS25FV1A
FVXS35FV1A
FVXS50FV1A
Heat pump
FLXS25BVMA
FLXS35BVMA
FLXS50BVMA
FLXS60BVMA
Cooling only
FFQ25B8V1B
FFQ35B8V1B
FFQ50B8V1B
FFQ60B8V1B
FFQ25B8V1B
FFQ35B8V1B
FFQ50B8V1B
FFQ60B8V1B
Duct-connected type
Fits in shallow ceiling recesses only 240 mm deep thanks to the new
slim and compact design.
Floor-standing type
New
Design
Floor/ceiling-suspended dual type
600 x 600 multi flow ceiling-mounted
cassette type
Suitable for the light
commercial market
Option
Heat pump
Possible combinations for indoor and outdoor units
Capacity class
Model
Cooling only type
3MKS58E
3MKS75E
4MKS90E
Heat pump type
3MXS52E
3MXS68E
4MXS80E
9
2.0 kW
2.5 kW
3.5 kW
5.0 kW
6.0 kW
Floor/ceiling-suspended dual type
Chose either ceiling-suspended or floor-level installation for this
attractive model with a beautiful, rounded design.
7.1 kW
600 x 600 multi flow ceiling-mounted cassette type
The compact and flexible design is suited to commercial spaces such
as offices.
10
Product lineup
Product lineup
W all-Mounted Type Indoor U nits
Quiet operation
GOOD DESIGN
AWARD 2004
IN JAPAN
Clean air
Wall-mounted type indoor units achieve quiet sound
levels of 22 dB during Indoor Unit Quiet Operation.
(H/L/SL)
FTXS20D FTXS25E FTXS35E
37/25/22 dB
38/26/23 dB
Option
2.0 kW class
2.5 kW class
3.5 kW class
Cooling only
FTKS20DVMA FTKS25EVMA FTKS35EVMA
Heat pump
FTXS20DVMA FTXS25EVMA FTXS35EVMA
Uses a Titanium Apatite Photocatalytic Air-Purifying
Filter. Titanium apatite is a photocatalytic material
with high adsorption power. It effectively adsorbs
and removes bacteria and viruses along with mould
and odours.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation
During cooling operation
Intelligent eye
Intelligent Eye with its infrared sensor automatically
controls air conditioner operation according to human
movement in a room. When there is no movement, it
adjusts the temperature by ± 2˚C for energy savings
of up to 20% for cooling operation and 30% for heating
operation. Intelligent Eye is available for all wall-mounted
models.
Top view
Air filter
Catches dust
7m
110˚
Option
5.0 kW class
6.0 kW class
7.1 kW class
Cooling only
FTKS50FVMA
FTKS60FVMA FTKS71FVMA
Heat pump
FTXS50FVMA
FTXS60FVMA FTXS71FVMA
Titanium Apatite
Photocatalytic
Air-purifying Filter
Side view
7m
Intelligent Eye sensor
Effect of Titanium Apatite Photocatalyst
90˚
ADSORB
REMOVE
Natural light
Odour
Bacteria
Evenly distributed air
Vertical and horizontal airflow is controlled
by Power-Airflow Dual Flaps and WideAngle Louvers working in tandem, realising
even distribution of air.
3-D airflow
Removed
Removed
Mould-proof operation
3-D Airflow combines Vertical and Horizontal AutoSwing to circulate air to every part of
a room for uniform cooling/heating of even large
spaces.
Econo Mode is a function that reduces the maximum
running current and the maximum power
consumption of the outdoor unit to the rated values.
This mode is useful for preventing circuit breakers from being
overloaded by the use of multiple air conditioners and other
electrical devices. The function is easily activated from the
remote controller by pushing the ECONO button. Econo
Mode is available for the FTK(X)D25/35D.
During cooling the Power-Airflow Dual Flaps flatten
Running current and
power consumption
Maximum
Normal
operation
Rated
A uniform temperature is
achieved throughout the
entire room.
When cooling or dry operation is stopped, fan-only
operation runs automatically for one hour. This
airflow dries the inside of the indoor unit to reduce
the generation of mould and the odours caused by
mould.
Maximum during
normal operation
Maximum during
Econo Mode
Econo
Mode
Easy cleaning
From start up until set
temperature is reached
11
Decomposed
Titanium Apatite Photocatalyst
Econo mode
During heating the near-vertical flaps direct air
Virus
Time
• This diagram is a representation for illustrative purposes only.
• Maximum capacity decreases during Econo Mode, requiring
more time to reach the set temperature.
Flat panel can be cleaned
with just a single pass of a
cloth across its smooth
surface.
12
Product lineup
Product lineup
Floor-Standing Type Indoor U nits
Dual air discharge for
enhanced comfort
New
Design
Daikin’s inverter floor standing split systems are especially
effective in heating. The unit features dual air outlets that
diffuse warm, cosy air at low floor level—where you need it
most in winter. This, combined with the vertical auto swing
louvres on the top air outlet, ensures uniform distribution of
heated air in the room.
Once winter is over, the lower air outlet can be shut off,
leaving the top air diffuser to stream cool refreshing air
upwards, allowing you to enjoy a cool, comfortable summer.
Versatile remote control
The remote controller with a backlit liquid crystal
display and luminescent control buttons also
features a built-in Weekly Timer that can be
programmed to suit your personal lifestyle, with up to four
actions per day for each day of the week.
This controller not only allows you to programme on and off
times, but also the desired temperature during those times.
Furthermore, the ‘copy’ function enables any daily
programme to be replicated on any other day or days as
required. Correct programming of the unit may also result in
considerable energy savings.
Stylish new design
2.5 kW class
Heat pump
3.5 kW class
The LCD panel
with backlight
5.0 kW class
FVXS25FV1A FVXS35FV1A FVXS50FV1A
A luminescent
material is used
for the buttons on
the surface.
User friendliness and operation in dark rooms, such as
bedrooms at night, has been improved.
Stylish and compact flat panel
The clever construction of the elegant flat panel unit allows
the flexibility of fully exposed installation against a wall or
semi-recessed installation in spaces such as in a
mantelpiece.
Weekly Timer
operation button
Easier cleaning
The flat panel design makes cleaning the front face
of the unit a breeze. Surface dust can be simply
wiped away with a soft cloth. Furthermore, the unit
can be installed off the floor to allow for cleaning of the floor
space under the unit.
Double airflow keeps feet warm during heating operation.
Clean air
3D ait filter catches dust.
Exposed portion of
unit only 115 mm
thick, allowing for
installation almost
anywhere.
Wiping clean the flat panel is a breeze.
Internal structure
Uses a Titanium Apatite Photocatalytic Air-Purifying
Filter. Titanium apatite is a photocatalytic material
with high adsorption power. It effectively adsorbs
and removes bacteria and viruses along with mould
and odours.
Easily clean beneath the unit.
13
Titanium apatite photocatalytic
air-purifying filter
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation
14
Product lineup
Product lineup
D uct-Connected Type Indoor U nits
Floor/Ceiling-Suspended Dual Type Indoor U nits
Option
2.5 kW class 3.5 kW class 5.0 kW class 6.0 kW class
700 mm width type
Cooling
only
Heat
pump
CDKS25EAVMA CDKS35EAVMA
CDXS25EAVMA CDXS35EAVMA
900/1,100 mm width type
Cooling
only
Heat
pump
CDKS25CVMA CDKS35CVMA CDKS50CVMA CDKS60CVMA
FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA
2.5 kW class 3.5 kW class 5.0 kW class 6.0 kW class
Heat
pump
FLXS25BVMA FLXS35BVMA FLXS50BVMA FLXS60BVMA
Slim and compact design
Models in the CDK(X)S-EA series are only 700 mm in width
and 21 kg in weight, so are easily installed in limited spaces.
Just 200 mm in height, all models can be installed in rooms
with as little as 240 mm depth between the drop ceiling and
ceiling slab, making them ideal for even shallow ceilings.
More
compact
Two-way installation
The rounded design of these slim and lightweight units
makes them the perfect choice for rooms without false
ceilings. Ceiling-suspended installation frees up floor and
wall space, and floor-level installation is possible without
loss of warm air.
CDK(X)S-EA
Air discharge
duct*
Only 700 mm
200 mm
240 mm
Suspension bolt*
Air filter
Air discharge
grille*
Chamber
CDK(X)S25EA CDK(X)S35EA C(F)DK(X)S25C C(F)DK(X)S35C
Dimensions (H x W x D)
200 x 700 x 620 mm 200 x 900 x 620 mm
Weight
21 kg
25 kg
Airflow rate (H)
8.7 m3/min
9.5 m3/min 10 m3/min
External static pressure
30 Pa
40 Pa
Quiet operation
Quiet operation sound level of only 29 dB is
achieved for 2.5 and 3.5 kW class models.
15
Comfortable airflow
Vertical Auto-Swing and Wide-Angle Louvers realise a
comfortable airflow spreading throughout a large room, airconditioning the whole room evenly.
AIR
Signal receiver wire
Length = 1,900 mm
Signals from the wireless remote controller
are transmitted to the signal receiver.
Ceiling-Suspended Installation
Signal
receiver
AIR
Air suction
grille*
Option
Suction grille (KDGF19A45)
* Locally obtained parts
Notes:
1. To prevent an increase in operation noise, avoid installing the air suction
grille directly below the suction chamber.
2. Grilles, piping connections, ducts, and installation parts should be
obtained locally.
Duct-connected types do not have drain-up pumps.
3. The signal receiver unit must be located near the air suction inlet,
because the unit includes a sensor that detects room temperature.
Quiet operation
The FLXS25B achieves the quiet sound level of
28 dB. Indoor Unit Quiet Operation decreases the
operation sound by 2 or 3 dB from the low setting
fan speed.
(H/L/SL)
FLXS25B
FLXS35B
37/31/28 dB
38/32/29 dB
During cooling operation
FLXS50B
47/39/36 dB
FLXS60B
48/41/39 dB
Floor-Level Installation
16
Product lineup
Product lineup
600 x 600 Multi Flow Ceiling-Mounted Cassette Type Indoor U nits
Suitable for the light commercial market
Wired LCD
remote controller
Wireless LCD
remote controller
Signal receiver unit
Wireles s remote
c ontroller and
s ignal rec eiver unit
are s old as a s et.
Option
Quiet sound levels of only 24.5 dB
Programme "Dry"
At low fan s peeds , the
2.5 kW model produc es
s ound of only 24.5 dB ,
and even the 6.0 kW
model as low as 32 dB .
This is due to a new
s piral hub c over that
reduc es internal airflow
res is tanc e.
Programme Dry gives priority to reduc ing the
level of
humidity rather than room temperature.
Dehumidific ation is c omputer c ontrolled to prevent
Switchable fan speed: High/Low
Spiral hub cover
(H/L)
FFQ25B
FFQ35B
FFQ50B
FFQ60B
29.5/24.5 dB
32/25 dB
36/27 dB
41/32 dB
Multi-Flow System
4-way blow
Option
3-way blow
2-way blow
Hot start (after defrost)
Unc omfortable c old air draft is not dis c harged
when heating operation s tarts or when s witc hing
to heat after defros ting.
Provided with condensate drain pump
750 mm
2.5 kW class 3.5 kW class 5.0 kW class 6.0 kW class
Cooling
only FFQ25B8V1B
Heat
pump
FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B
FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B
Low draft performance is
superior by design
Designed to fit 600 mm wide
ceiling grids perfectly
575 mm
0°
Horizontal Blow
286
mm
L it t le fe e lin g
o f blo w in g a ir
" " denotes piping direction. "
outlet (option).
4 patterns
1 pattern
Air discharge patterns can be selected
according to installation.
Conditioned air is distributed Adjustable air blow angle to
evenly by Auto-swing
suit all room conditions.
operation.
5 directions
AUTO-SWING
Standard
setting
0°
0°
Auto-s wing
between 0° and 60°
60°
Draft
prevention
setting
(Set on site)
Setting to
prevent
soiling of
ceiling
(Set on site)
60°
Settable to 5 different levels
between 0° and 60°
0°
0°
35°
Auto-s wing
between 0° and 35°
25°
60°
Auto-s wing
between 25° and 60°
35°
25°
60°
Settable to 5 different levels
between 0° and 35°
Settable to 5 different levels
between 25° and 60°
Note: Angles shown above are provided as a guide. They may differ depending on the installation site.
17
Ceiling panel
T bar
Long-life filter
Note:
Operation nois e
inc reas es when
us ing 2-way or 3way blow.
Two selectable temperature sensors
600 mm
600 mm
Even for modules other than 600 x 600, no inspection
opening is required. Maintenance can be performed after
simply removing the grille, because the switchbox is built
into the unit.
The filter has s anitary, mould-res is tant
If there is a power failure while the unit is
operating, the s ys tem will res tart in the s ame
mode when power is res tored.
700 mm
T-bar grid does not need to be cut
Mould-resistant treatment for filter
Auto-restart
act
C om p e pa ne l
r a t iv
de c o
700 mm
Comfortable across all areas
To facilitate recycling, the composition of each
plastic component is marked on the part.
" denotes sealing member for air discharge
Note: For 3-way or 2-way blow ins tallation, the s ealing member for air
dis c harge outlet (option) mus t be us ed to c los e off the unus ed
outlet(s ).
575 mm
0°
1 pattern
B oth indoor unit and wired remote c ontroller
(option) c ontain temperature s ens ors . Temperature
s ens ing c an be s et at the unit or, to further
improve c omfort level, c los er to the target area
at the wired remote c ontrol.
*Temperature s ens or on indoor unit mus t be us ed when the air
c onditioner is c ontrolled from another room.
(Wireles s remote c ontroller does not have a temperature s ens or.)
Maintenanc e is not required for one year.
Ceiling soiling prevention function
Daikin's innovative air dis c harge mec hanis m
keeps air flow away from the c eiling. C eiling
c leaning is required les s frequently.
Filter sign
When the filter requires c leaning, the filter
ic on is dis played on the remote c ontroller.
18
Functions
Functions
Models
Indoor units
Wall-mounted type
Outdoor units
Duct-connected type
Floor-standing type
Floor/ceiling-suspended dual type
CDK(X)S/FDXS
FVXS
FLXS
Easy-to-use wireless remote controller
Sets room
temperature
Home
Leave
Operation
Vertical Auto-Swing
(up and down)
Econo Mode
Inverter
Powerful
Operation
On/Off Switch
Sets room
temperature
On/Off Switch
Selects fan speed and
Indoor Unit Quiet Operation
Selects mode: automatic, cooling,
heating, dry, fan-only operation
Intelligent Eye
Mould-Proof
Operation
Inverter
Powerful
Operation
Outdoor Unit Quiet Operation
Horizontal
Auto-Swing
(left and
right)
Cancels On/Off Timer
24-Hour On Timer
Displays time
Comfortable Airflow
FTK(X)S50/60/71F
Comfort Control
FTK(X)S20/25/35
Functions
Power-Airflow
Dual Flaps
Wide-Angle Louvres
Vertical Auto-Swing
(up and down)
Horizontal Auto-Swing
(left and right)
3-D Airflow
Indoor Unit Quiet
Operation
Outdoor Unit Quiet
Operation
Night Quiet Mode
Intelligent Eye
Automatic Operation
(Heat pump type only)
Auto Fan Speed
Lifestyle Convenience
Sets timer
FVXS25/35/50F
Inverter Powerful
Operation
Econo Mode
On/Off Switch
Sets room temperature
Cleanliness
Selects fan speed and
Indoor Unit Quiet Operation
Priority-Room Setting
Mould-Proof Air Filter
New
Timers
Weekly Timer
New
Night Set Mode
Worry Free
24-Hour On Timer
Displays time
Air-Purifying Filter
24-Hour On/Off Timer
Weekly Timer
Cancels On/Off Timer
Photocatalytic
Deodourising Filter
Wipe-Clean Flat Panel
Outdoor Unit Quiet Operation
24-Hour Off Timer and Night Set Mode
New
Mould-Proof Operation
Inverter Powerful Operation
Econo Mode
Sets timer
New
Home Leave
Operation
Indoor Unit On/Off
Switch
Titanium Apatite
Photocatalytic
Air-Purifying Filter
Selects mode: automatic, cooling,
heating, dry, fan-only operation
FTK(X)S50-71F
Programme Dry Function
24-Hour Off Timer
and Night Set Mode
Vertical Auto-Swing (up and down)
FTK(X)S20-35
Auto-Restart after
Power Failure
Self-Diagnosis with
Digital Display
Anticorrosion Treatment of
Outdoor Heat Exchanger Fins
Please refer to pages 17 and 18 for the features of the 600 x 600 multi flow ceiling-mounted cassette type.
19
20
Functions
Comfortable Airflow
Functions
Automatic Operation
This function automatically selects cooling or heating
operation mode based on the room temperature at startup.
Power-Airflow Dual Flaps
Power-Airflow Dual Flaps can flatten out during cooling
operation to deliver cool air to the corners of
a room. The flaps can direct warm air straight down to
the floor during heating operation.
Wide-Angle Louvres
Smoothly curved Wide-Angle Louvres provide wide
airflow coverage for effective cooling/heating no matter
where the indoor unit is placed in a room.
Vertical Auto-Swing (up and down)
Vertical Auto-Swing automatically moves the flaps up and
down to provide an even distribution of air throughout a room.
Programme Dry Function
This function automatically reduces the level of humidity
while maintaining the preset room temperature.
Auto Fan Speed
The microprocessor automatically controls fan speed to
adjust the room temperature to the set temperature.
Lifestyle Convenience
Inverter Powerful Operation
Horizontal Auto-Swing automatically moves the louvres
to the left and right to cover a room with cool/warm air.
This function is convenient for boosting cooling/heating
performance for a 20-minute period both when you first
turn on your air conditioner and want to quickly change
the room temperature.
3-D Airflow
Econo Mode
Horizontal Auto-Swing (left and right)
This function combines Vertical and Horizontal
Auto-Swing to circulate a cloud of cool/warm air right
to the corners of even large spaces.
Comfort Control
Indoor Unit Quiet Operation
Indoor unit operating sound levels are decreased by 2 or
3 dB from the low setting fan speed using the wireless
remote controller.
Econo Mode reduces the maximum running current and
maximum power consumption of the outdoor unit to the
rated values. This is useful when using multiple air
conditioners and other electrical devices at the same
time.
Home Leave Operation
Home Leave Operation continues operation to prevent
a room from becoming too hot or cold while you are
sleeping or out of your home. Select any temperature
from 18 to 32˚C for cooling operation and 10 to 30˚C for
heating operation.
See page 6
Outdoor Unit Quiet Operation
Outdoor unit operating sound levels are decreased by 3 dB
from the rated operation sound using the wireless remote
controller.
Indoor Unit On/Off Switch
There is a second On/Off switch on the body of the indoor
unit to prevent any problems if the wireless remote
controller is misplaced.
Night Quiet Mode
Outdoor unit operating sound levels are automatically
decreased by 3 dB from the rated operation sound when
the outdoor temperature has dropped by 6˚C from the
maximum temperature recorded during the daytime.
Initial setting is required during installation.
Intelligent Eye
Intelligent Eye with its infrared sensor automatically
controls air conditioner operation according to human
movement in a room. When there is no movement, it
adjusts the temperature by ± 2˚C for energy savings of
up to 20% for cooling operation and 30% for heating
operation.
When this function is set, it is convenient for selecting Inverter
Powerful Operation, Outdoor Unit Quiet Operation and
operation mode. Initial setting is required during installation.
See page 8
Pressing the Off timer button automatically selects the
Night Set Mode. This function prevents any sudden
change in room temperature by gently raising/lowering
the temperature before the air conditioner stops, so you
can sleep more comfortably.
Titanium Apatite Photocatalytic
Air-Purifying Filter
This filter combines the Air-Purifying Filter and
Titanium Apatite Photocatalytic Deodourising Filter
in a single highly effective unit. The filter traps
microscopic particles, decomposes odours and
even removes bacteria and viruses. It lasts for 3
years without replacement if washed about once
every 6 months.
Worry Free
Auto-Restart After Power Failure
The air conditioner memorises the settings for mode,
airflow, temperature, etc., and automatically returns to
them when power is restored after a power failure.
Photocatalytic Deodourising Filter
This filter decomposes odours and even removes
bacteria and viruses. This power is maintained simply by
exposing the filter to sunlight once every 6 months.
Self-Diagnosis with Digital Display
Air-Purifying Filter
Anticorrosion Treatment of Outdoor Heat Exchanger Fins
Malfunction codes for each indoor unit are shown on the
digital display panel of the wireless remote controller for
fast and easy maintenance.
The filter removes bacteria and viruses, and impurities
such as dust, pollen and cigarette smoke from the air.
The outdoor unit’s heat exchanger fins are processed
using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the fins’
resistance to acid rain and salt corrosion.
Mould-Proof Air Filter
The air filter net is impregnated with a safe, odourless
mould preventative to make the filter virtually immune to
mould.
Mould-Proof Operation
Mould-Proof Operation automatically runs fan-only
operation for 1 hour when cooling or dry operation is
stopped. This airflow prevents the generation of mould
and mould odours inside the indoor unit.
Others
Comfort Control
Quick Warming Function
During low outdoor temperatures, this function preheats the
compressor to shorten the time required to discharge warm air.
Automatic Defrosting
Wipe-Clean Flat Panel
Before starting heating operation, a sensor checks for frost in
the outdoor unit and performs automatic defrosting if necessary
so that only warm air is discharged.
The flat panel models can be cleaned with only the single
pass of a cloth across their smooth surface. The flat panel
can also be easily removed for more thorough cleaning.
See pages 12 and 13
Hot-Start Function
After defrosting or when starting heating operation, air is
preheated before discharge to prevent uncomfortable cold
drafts.
Timers
See page 6
Priority-Room Setting
Night Set Mode
Cleanliness
24-Hour On/Off Timer
Worry Free
Cooling/Heating Mode Lock
This timer can be preset to start and stop at any time
within a 24-hour period. The air conditioner is started/
stopped simply by pressing the On/Off timer button on
the wireless remote controller.
The owner can lock the operation mode to prevent it from being
changed in individual rooms. This is convenient in small hotels.
Wiring Error Check
Microcomputer checking and diagnosis of wiring errors during
installation prevents any problems.
Weekly Timer
This timer can be preprogrammed with settings for day of
the week, time of day, temperature, and operation on/off.
A maximum of four air conditioner start or stop points
can be entered per day for each of seven days in a oneweek period simply by pressing the WEEKLY button.
Flexibility
See page 14
Chargeless
Charging with additional refrigerant is not required even for
long runs of piping. Available for cooling only type.
Either Side Drain (left or right)
The wall-mounted type indoor unit is designed so that drain
piping can be connected to either the left or right side.
Refer to page 20 to check the functions offered by individual models.
21
22
Specifications
Specifications
Specifications
Outdoor units
Model name
Power supply
Max. connected indoor units capacity
Casing colour
Compressor type
Refrigerant type
Cooling
Sound level*1
Heating
Cooling
Sound power
level
Heating
Dimensions (H x W x D)
Machine weight
Cooling
Operation
range
Heating
Max. piping length
kW
dB (A)
dB (A)
mm
kg
˚CDB
˚CWB
m
Necessity of additional charge
Max. installation height difference
Heat pump
4MKS90EVMA
3MXS52EVMA
3MXS68EVMA
4MXS80EVMA
1 phase, 230-240 V, 50 Hz
10.0
13.5
15.6
9.0
11.0
14.5
Ivory white
Hermetically sealed swing type
R-410A
46/43
46/43
48/45
48/45
—
47/44
49/46
59
59
61
61
—
60
62
735 x 936 x 300
770 x 900 x 320
735 x 936 x 300
770 x 900 x 320
69
72
49
58
49
59
-5 to 46
10 to 46
-10 to 46
—
-15 to 15.5
50 (total)
60 (total)
70 (total)
50 (total)
60 (total)
70 (total)
25 (for each room)
20 (for 30 m or more)*2
Chargeless
20 (for 40 m or more)*2
15 (between indoor and outdoor units)/15 (between indoor units)
15 (between indoor and outdoor units)/7.5 (between indoor units)
3MKS58EVMA
g/m
m
Cooling only
3MKS75EVMA
Notes: *1. Rated sound level/sound level when Indoor Unit Quiet Operation and Outdoor Unit Quiet Operation are both selected for all indoor units in operation.
*2. Additional charging of 20 g/m is required for the 3MXS52EVMA and 3MXS68EVMA when the piping length is 30 m or more and for the 4MXS80EVMA when the piping length is 40 m
or more.
Indoor units
Wall-mounted type
Model name
Power supply
Front panel colour
Airflow rates (H)
/s (cfm)
dB (A)
Sound level (H/L/SL)
dB (A)
Sound power level (H)
Fan speed
Temperature control
mm
Dimensions (H x W x D)
kg
Machine weight
Liquid (flare)
Piping connections Gas (flare) mm
Drain
Heat insulation
Model name
Power supply
Front panel colour
Airflow rates (H)
Sound level
(H/L/SL)
Cooling
Heating
Cooling
Heating
Cooling
Heating
/s
(cfm)
dB (A)
Sound power
dB (A)
level (H)
Fan speed
Temperature control
mm
Dimensions (H x W x D)
kg
Machine weight
Liquid (flare)
Piping connections Gas (flare) mm
Drain
Heat insulation
23
Cooling only
FTKS25EVMA
FTKS35EVMA
FTKS50FVMA
FTKS60FVMA
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
White
148 (314)
245 (519)
270 (572)
145 (307)
37/25/22
38/26/23
44/35/32
45/36/33
53
54
60
61
5 steps, quiet and automatic
Microcomputer control
283 x 800 x 195
290 x 1,050 x 238
12
9
ø6.4
ø9.5
ø12.7
ø18.0
Both liquid and gas pipes
Heat pump
FTXS20DVMA
FTXS25EVMA
FTXS35EVMA
FTXS50FVMA
FTXS60FVMA
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
White
145 (307)
148 (314)
245 (519)
270 (572)
157 (332)
162 (342)
270 (572)
290 (614)
37/25/22
38/26/23
44/35/32
45/36/33
37/28/25
38/29/26
42/33/30
44/35/32
53
54
60
61
53
54
58
60
5 steps, quiet and automatic
Microcomputer control
283 x 800 x 195
290 x 1,050 x 238
12
9
ø6.4
ø9.5
ø12.7
ø18.0
FTKS20DVMA
FTKS71FVMA
290 (614)
46/37/34
62
ø15.9
<
Indoor units
>
Duct-connected type 700 mm width
Model name
Power supply
Airflow rates
(H)
Sound level*
(H/L/SL)
CDKS25EAVMA
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling only
/s
(cfm)
—
dB(A)
—
Sound power
dB(A)
level (H)
Fan speed
Temperature control
Dimensions (H x W x D)
mm
Machine weight
kg
Liquid (flare)
Piping
Gas (flare)
mm
connections
Drain
Heat insulation
External static pressure
Pa
—
Heat pump
CDKS35EAVMA
CDXS25EAVMA
CDXS35EAVMA
1 phase, 220-240 V, 50 Hz/1 phase, 220-230 V, 60 Hz
145 (307)
145 (307)
35/31/29
35/31/29
53
53
5 steps, quiet and automatic
Microcomputer control
200 x 700 x 620
21
ø6.4
ø9.5
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
30
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for CDK(X)S-EA. Sound level values for bottomsuction operation can be obtained by adding 6 dB to the CDK(X)S-EA values.
<
>
Duct-connected type 900/1,100 mm width
Cooling only
Heat pump
Model name
CDKS25CVMA CDKS35CVMA CDKS50CVMA CDKS60CVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA
Power supply
1 phase, 220-240 V, 50 Hz/1 phase, 220 V, 60 Hz
158 (335)
167 (353)
200 (424)
267 (565)
158 (335)
167 (353)
200 (424)
267 (565)
Cooling
/s
Airflow rates (H)
(cfm)
—
158 (335)
167 (353)
200 (424)
267 (565)
Heating
Cooling
35/31/29
37/33/31
38/34/32
35/31/29
37/33/31
38/34/32
Sound level*
dB (A)
(H/L/SL)
—
Heating
35/31/29
37/33/31
38/34/32
Cooling
53
55
56
53
55
56
Sound power
dB (A)
level (H)
—
Heating
53
55
56
Fan speed
5 steps, quiet and automatic
Temperature control
Microcomputer control
200 x 900 x 620
200 x 900 x 620
Dimensions (H x W x D)
mm
200 x 1,100 x 620
200 x 1,100 x 620
Machine weight
kg
25
27
30
25
27
30
Liquid (flare)
ø6.4
Piping connections Gas (flare)
mm
ø9.5
ø9.5
ø12.7
ø12.7
Drain
VP 20 (External Dia. 26/Internal Dia. 20)
Heat insulation
Both liquid and gas pipes
External static pressure
Pa
40
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 40 Pa for CDKS/FDXS-C. Sound level values for bottomsuction operation can be obtained by adding 5 dB to the CDKS/FDXS-C values.
FTXS71FVMA
290 (614)
358 (759)
46/37/34
46/37/34
62
62
ø15.9
Floor-standing type
Model name
Power supply
Front panel colour
Airflow rates
(H)
Sound level
(H/L/SL)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Sound power
level (H)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Liquid (flare)
Piping
Gas (flare)
connections
Drain
Heat insulation
FVXS25FV1A
/s
(cfm)
dB (A)
dB (A)
137 (290)
147 (311)
38/26/23
38/26/23
54
54
mm
kg
mm
ø9.5
FVXS35FV1A
1 phase, 220-230-240 V, 50 Hz
White
142 (300)
157 (332)
39/27/24
39/27/24
55
55
5 steps, quiet and automatic
Microcomputer control
600 x 700 x 210
14
ø6.4
ø20.0
Both liquid and gas pipes
FVXS50FV1A
178 (378)
197 (417)
44/36/32
45/36/32
56
57
ø12.7
24
Specifications
Options
Options
Floor/ceiling-suspended dual type
Model name
Power supply
Front grille colour
Airflow rates
(H)
Sound level
(H/L/SL)
Sound power
level (H)
FLXS25BVMA
Cooling
Heating
Cooling
Heating
Cooling
Heating
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Liquid (flare)
Piping
Gas (flare)
connections
Drain
Heat insulation
/s
(cfm)
dB (A)
dB (A)
126 (268)
153 (325)
37/31/28
37/31/29
53
53
mm
kg
16
mm
ø9.5
FLXS35BVMA
FLXS50BVMA
1 phase, 230 V, 50 Hz
Almond white
143 (304)
190 (402)
163 (346)
202 (427)
38/32/29
47/39/36
39/33/30
46/35/33
54
63
55
62
5 steps, quiet and automatic
Microcomputer control
490 x 1,050 x 200
ø6.4
ø18.0
Both liquid and gas pipes
Outdoor units
FLXS60BVMA
200 (424)
213 (452)
48/41/39
47/37/34
64
63
No.
1
2
3MXS52E
Item
Air direction adjustment grille
Drain plug
3MKS58E
3MXS68E
3MKS75E
KPW945A4
17
Heat pump
Model name
FFQ25B8V1B
FFQ60B8V1B FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B
Power supply
1 phase, 230 V, 50 Hz
Cooling
150 (318)
167 (353)
200 (424)
250 (530)
150 (318)
167 (353)
200 (424)
250 (530)
/s
Airflow rates
(cfm)
(H)
Heating
150 (318)
167 (353)
200 (424)
250 (530)
—
Cooling
Sound level*
29.5/24.5
32/25
36/27
41/32
29.5/24.5
32/25
36/27
41/32
dB (A)
(H/L)
Heating
29.5/24.5
32/25
36/27
41/32
—
Cooling
Sound power
46.5
49
53
58
46.5
49
53
58
dB (A)
level (H)
Heating
46.5
49
53
58
—
Fan speed
2 steps
Temperature control
Microcomputer control
Unit dimensions (H x W x D)
mm
286 x 575 x 575
Machine weight
kg
17.5
Liquid
(flare)
ø6.4
Piping
Gas (flare)
mm
ø9.5
ø12.7
ø9.5
ø12.7
connections
Drain
VP20 (External Dia. 26/Internal Dia. 20)
Heat insulation
Both liquid and gas pipes
Model
BYFQ60B7W1
Colour
White
Panel
(option)
Dimensions (H x W x D) mm
55 x 700 x 700
Weight
kg
2.7
Drain plug
KKP937A4
Indoor units
ø12.7
Cooling only
FFQ35B8V1B FFQ50B8V1B
4MKS90E
Notes: *1. One set includes 5 pieces for 5 units.
*2. One set includes 1 piece for 1 unit.
Air direction adjustment grille
KPW945A4
600 x 600 multi flow ceiling-mounted cassette type
4MXS80E
1
2
3
4
5
6
7
8
9
10
11
12
Wall-mounted type
FTK(X)S20-35
FTK(X)S50-71F
Item
No.
Wired remote controller*1
Wired remote controller Length 3 m (shielded wire)
cord
Length 8 m (shielded wire)
5-room centralised controller*2
Wiring adaptor for time clock/remote controller*3
(Normal open pulse contact/normal open contact)
KAF970A46 KAF952B42
Titanium apatite photocatalytic air-purifying filter*4
Photocatalytic deodourising filter with frame*5
Photocatalytic deodourising filter without frame*5
Air-purifying filter with frame*6
Air-purifying filter without frame*6
Wireless remote controller loss prevention chain
—
Suction grille
—
Insulation kit for high humidity
Duct-connected type
Floor-standing
Floor/ceilingtype
suspended dual type
CDK(X)S25/35EA C(F)DK(X)S25-50C C(F)DK(X)S60C
BRC944A2B
—
BRCW901A03
—
BRCW901A08
—
KRC72
KRP413A1S
—
—
—
—
KKF917A4
KDT25N32
—
KAF968A42
KDGF19A45
KDT25N50 KDT25N63
KKF910A4
—
—
—
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
KKF917A4
Notes: *1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.
*2. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
*3. Time clock and other devices should be obtained locally.
*4. Filter is a standard accessory. It should be replaced after approximately 3 years.
*5. The photocatalytic deodourising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months.
This accessory is only required if the original filter is damaged or lost, etc.
*6. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Measurement conditions
1. Cooling operation data is based on the following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
2. Heating operation data is based on the following conditions: indoor temp. 20°CDB, 19°CWB; outdoor temp. 7°CDB, 6°CWB; piping length 7.5 m.
3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Wired remote
controller
BRC944A2B
5-room centralised
controller
KRC72
No.
1
Decoration panel
2
Remote controller
3
4
5
6
7
8
9
10
Adaptor for wiring*2
Wiring adaptor for electrical appendices*2
Installation box for adaptor PCB
Remote sensor
Replacement long-life filter
Fresh air intake kit
Direct installation type
Sealing member for air discharge outlet
Panel spacer
Titanium apatite photocatalytic
air-purifying filter
KAF952B42
600 x 600 multi flow ceiling-mounted cassette type
BYFQ60B7W1
BRC1C61
BRC7E530W7
BRC1E531W7
KRP1BA57
KRP4AA53
KRP1BA101
KRCS01-1A
KAFQ441BA60
KDDQ44XA60
KDBH44BA60
KDBQ44B60A
Item
Wired type*1
Wireless type
Remote controller loss
prevention chain
KKF917A4
Heat pump use
Cooling only use
Notes: *1. Wiring for wired remote controller should be obtained locally.
*2. Installation box for adaptor PCB (KRP1BA101) is necessary.
System configurations
No.
1
2
3
4
Item
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor for DIII-NET use
Wall-mounted type Duct-connected type Floor-standing type
DCS302CA61
DCS301BA61
DST301BA61
KRP928B2S
Floor/ceiling-suspended dual type
Note: * A wiring adaptor (KRP928B2S) is also required for each indoor unit.
Central remote controller
DCS302CA61
25
Unified on/off controller
DCS301BA61
Schedule timer
DST301BA61
26
Capacity tables
Capacity tables
Cooling only type
Outdoor
unit
3MKS58EVMA
3MKS75EVMA
27
Combinations
of indoor units
20
25
35
50
20+20
20+25
20+35
20+50
25+25
25+35
25+50
35+35
35+50
50+50
20+20+20
20+20+25
20+20+35
20+20+50
20+25+25
20+25+35
20+25+50
20+35+35
25+25+25
25+25+35
25+25+50
25+35+35
20
25
35
50
60
71
20+20
20+25
20+35
20+50
20+60
20+71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
20+20+20
20+20+25
20+20+35
20+20+50
20+20+60
20+20+71
20+25+25
20+25+35
20+25+50
20+25+60
20+25+71
20+35+35
20+35+50
20+35+60
20+35+71
20+50+50
20+50+60
25+25+25
25+25+35
25+25+50
25+25+60
240 V, 50 Hz
Capacity of each indoor unit (kW)
A room
2.00
2.50
3.50
5.00
2.00
2.00
1.86
1.56
2.50
2.18
1.86
2.73
2.39
2.90
1.74
1.64
1.49
1.29
1.56
1.42
1.22
1.28
1.86
1.71
1.45
1.52
2.00
2.50
3.50
5.00
6.00
7.10
2.00
2.00
2.00
1.93
1.77
1.62
2.50
2.50
2.30
2.12
1.95
3.50
2.96
2.76
2.48
3.75
3.41
3.10
3.75
3.44
2.00
2.03
1.84
1.63
1.50
1.35
1.93
1.76
1.58
1.43
1.29
1.63
1.43
1.30
1.19
1.24
1.15
2.30
2.12
1.88
1.70
B room
2.00
2.50
3.25
3.90
2.50
3.05
3.71
2.73
3.41
2.90
1.74
1.64
1.49
1.29
1.95
1.78
1.53
2.26
1.86
1.71
1.45
2.14
2.00
2.50
3.50
4.82
5.28
5.76
2.50
3.50
4.60
5.08
5.55
3.50
4.24
4.74
5.02
3.75
4.09
4.40
3.75
4.06
2.00
2.03
1.84
1.63
1.50
1.35
2.41
2.22
1.97
1.79
1.62
2.86
2.50
2.29
2.08
3.13
2.89
2.30
2.12
1.88
1.70
C room
1.74
2.05
2.60
3.22
1.95
2.49
3.05
2.26
1.86
2.38
2.90
2.14
2.00
2.54
3.22
4.09
4.50
4.80
2.41
3.07
3.95
4.28
4.59
2.86
3.57
3.91
4.23
3.13
3.46
2.30
2.96
3.74
4.10
D room
Total capacity (kW)
Rated (Min._ Max.)
Total power consumption (W)
Rated (Min._ Max.)
Total current (A)
Rated (Min._ Max.)
2.00 (1.76–3.06)
2.50 (1.76–3.30)
3.50 (1.76–4.56)
5.00 (1.85–5.82)
4.00 (1.88–5.96)
4.50 (1.88–6.23)
5.11 (1.88–6.24)
5.46 (1.88–6.91)
5.00 (1.88–6.23)
5.23 (1.88–6.35)
5.57 (1.88–6.91)
5.46 (1.88–6.40)
5.80 (1.88–6.92)
5.80 (1.83–7.00)
5.22 (1.86–7.04)
5.33 (1.86–7.04)
5.58 (1.95–7.06)
5.80 (1.77–7.30)
5.46 (1.86–7.04)
5.69 (1.95–7.06)
5.80 (1.77–7.30)
5.80 (1.86–7.07)
5.58 (1.95–7.04)
5.80 (1.95–7.06)
5.80 (1.77–7.30)
5.80 (1.95–7.07)
2.00 (1.70–2.97)
2.50 (1.70–3.46)
3.50 (1.71–4.79)
5.00 (1.83–5.94)
6.00 (1.92–6.45)
7.10 (2.06–7.17)
4.00 (1.73–5.22)
4.50 (1.83–5.70)
5.50 (1.92–6.25)
6.75 (2.15–7.17)
7.05 (2.21–7.52)
7.38 (2.32–7.87)
5.00 (1.83–6.10)
6.00 (1.92–6.49)
6.90 (2.10–7.31)
7.20 (2.21–7.66)
7.50 (2.32–8.00)
7.00 (2.06–7.16)
7.20 (2.21–7.65)
7.50 (2.32–7.95)
7.50 (2.42–8.27)
7.50 (2.40–8.09)
7.50 (2.48–8.32)
7.50 (2.61–8.50)
7.50 (2.60–8.50)
7.50 (2.74–8.62)
6.00 (1.95–6.75)
6.60 (2.00–7.07)
6.90 (2.10–7.46)
7.35 (2.23–8.05)
7.50 (2.40–8.39)
7.50 (2.49–8.66)
6.75 (2.10–7.29)
7.05 (2.21–7.66)
7.50 (2.40–8.23)
7.50 (2.40–8.57)
7.50 (2.49–8.79)
7.35 (2.21–8.05)
7.50 (2.40–8.57)
7.50 (2.48–8.72)
7.50 (2.64–8.95)
7.50 (2.70–8.86)
7.50 (2.78–8.97)
6.90 (2.10–7.46)
7.20 (2.21–7.87)
7.50 (2.40–8.36)
7.50 (2.48–8.63)
460 (350– 810)
620 (350– 820)
960 (350–1,510)
1,540 (350–1,980)
950 (350–1,910)
1,180 (350–2,140)
1,520 (350–2,070)
1,400 (350–2,070)
1,450 (350–2,140)
1,580 (350–2,160)
1,470 (350–2,070)
1,720 (350–2,160)
1,600 (350–2,080)
1,540 (350–2,110)
1,260 (350–2,160)
1,310 (350–2,160)
1,410 (370–2,160)
1,540 (350–2,190)
1,380 (350–2,160)
1,480 (370–2,160)
1,540 (350–2,240)
1,570 (350–2,160)
1,410 (370–2,160)
1,570 (370–2,160)
1,540 (350–2,240)
1,570 (380–2,160)
500 (420– 790)
650 (420– 920)
1,010 (420–1,410)
1,560 (450–1,990)
2,100 (440–2,320)
2,820 (460–2,840)
1,170 (360–1,610)
1,420 (390–1,860)
1,950 (420–2,350)
2,310 (430–2,470)
2,430 (430–2,570)
2,620 (450–2,890)
1,660 (390–2,040)
2,300 (420–2,490)
2,400 (410–2,570)
2,620 (420–2,710)
2,760 (440–3,020)
2,790 (460–3,140)
2,620 (440–2,810)
2,840 (460–3,050)
2,740 (490–3,210)
2,590 (460–2,900)
2,540 (480–3,060)
2,500 (510–3,170)
2,500 (510–3,170)
2,450 (540–3,210)
1,680 (350–2,020)
2,000 (380–2,200)
2,180 (400–2,510)
2,260 (420–2,650)
2,310 (450–2,810)
2,310 (470–2,960)
2,090 (380–2,390)
2,250 (430–2,590)
2,360 (450–2,810)
2,310 (450–2,860)
2,260 (470–3,020)
2,440 (420–2,890)
2,360 (450–3,070)
2,260 (480–2,960)
2,240 (510–3,180)
2,130 (510–2,920)
2,080 (560–3,090)
2,180 (380–2,490)
2,350 (420–2,740)
2,360 (450–2,860)
2,260 (480–2,960)
2.0 (1.5– 3.2)
2.7 (1.5– 3.2)
4.1 (1.5– 5.5)
6.5 (1.5– 8.3)
4.0 (1.5– 8.0)
5.0 (1.5– 9.0)
6.4 (1.5– 8.7)
5.9 (1.5– 8.7)
6.1 (1.5– 9.0)
6.6 (1.5– 9.1)
6.2 (1.5– 8.7)
7.2 (1.5– 9.1)
6.7 (1.5– 8.8)
6.5 (1.5– 8.9)
5.3 (1.5– 9.1)
5.5 (1.5– 9.1)
5.9 (1.6– 9.1)
6.5 (1.5– 9.2)
5.8 (1.5– 9.1)
6.2 (1.6– 9.1)
6.5 (1.5– 9.4)
6.6 (1.5– 9.1)
5.9 (1.6– 9.1)
6.6 (1.6– 9.1)
6.5 (1.5– 9.4)
6.6 (1.6– 9.1)
2.3 (1.9– 3.6)
3.0 (1.9– 4.2)
4.4 (1.8– 6.2)
6.6 (1.9– 8.5)
8.8 (1.9– 9.8)
11.9 (1.9–12.0)
5.0 (1.5– 6.8)
6.0 (1.7– 7.9)
8.2 (1.8– 9.9)
9.7 (1.8–10.4)
10.2 (1.8–10.8)
11.0 (1.9–12.2)
7.1 (1.7– 8.7)
9.7 (1.8–10.5)
10.1 (1.7–10.8)
11.0 (1.8–11.4)
11.6 (1.9–12.7)
11.7 (1.9–13.2)
11.0 (1.9–11.8)
12.0 (1.9–12.8)
11.5 (2.1–13.5)
10.9 (1.9–12.2)
10.7 (2.0–12.9)
10.5 (2.1–13.3)
10.5 (2.1–13.3)
10.3 (2.3–13.5)
7.1 (1.5– 8.5)
8.4 (1.6– 9.3)
9.2 (1.7–10.6)
9.5 (1.8–11.2)
9.7 (1.9–11.8)
9.7 (2.0–12.5)
8.8 (1.6–10.1)
9.5 (1.8–10.9)
9.9 (1.9–11.8)
9.7 (1.9–12.0)
9.5 (2.0–12.7)
10.3 (1.8–12.2)
9.9 (1.9–12.9)
9.5 (2.0–12.5)
9.4 (2.1–13.4)
9.0 (2.1–12.3)
8.8 (2.4–13.0)
9.2 (1.6–10.5)
9.9 (1.8–11.5)
9.9 (1.9–12.0)
9.5 (2.0–12.5)
Outdoor
unit
3MKS75EVMA
4MKS90EVMA
Combinations
of indoor units
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
35+35+35
35+35+50
35+35+60
35+50+50
20
25
35
50
60
71
20+20
20+25
20+35
20+50
20+60
20+71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
71+71
20+20+20
20+20+25
20+20+35
20+20+50
20+20+60
20+20+71
20+25+25
20+25+35
20+25+50
20+25+60
20+25+71
20+35+35
20+35+50
20+35+60
20+35+71
20+50+50
20+50+60
20+50+71
20+60+60
20+60+71
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
25+50+71
25+60+60
25+60+71
Capacity of each indoor unit (kW)
A room
1.55
1.98
1.70
1.56
1.43
1.50
1.39
2.50
2.19
2.02
1.94
2.00
2.50
3.50
5.00
6.00
7.10
2.00
2.00
2.00
2.00
1.84
1.69
2.50
2.50
2.40
2.21
2.03
3.50
3.09
2.87
2.63
3.95
3.73
3.52
4.25
3.92
4.33
2.00
2.00
1.92
1.70
1.59
1.48
2.00
1.84
1.64
1.54
1.45
1.70
1.54
1.45
1.38
1.42
1.35
1.28
1.28
1.19
2.40
2.21
1.98
1.87
1.76
2.05
1.87
1.77
1.68
1.72
1.65
1.54
1.56
1.44
B room
1.55
2.76
2.39
2.19
2.00
3.00
2.78
2.50
2.19
2.02
2.78
C room
4.40
2.76
3.41
3.75
4.07
3.00
3.33
2.50
3.12
3.46
2.78
2.00
2.50
3.50
5.00
5.52
5.98
2.50
3.50
4.81
5.29
5.78
3.50
4.41
4.92
5.32
3.95
4.48
5.01
4.25
4.63
4.33
2.00
2.00
1.92
1.70
1.59
1.48
2.50
2.30
2.05
1.92
1.81
2.97
2.69
2.54
2.41
3.54
3.38
3.19
3.86
3.58
2.40
2.21
1.98
1.87
1.76
2.87
2.61
2.48
2.35
3.46
3.31
3.08
3.72
3.46
2.00
2.50
3.37
4.24
4.75
5.28
2.50
3.22
4.10
4.61
5.13
2.97
3.84
4.37
4.88
3.54
4.06
4.53
3.86
4.23
2.40
3.08
3.97
4.47
5.01
2.87
3.73
4.25
4.78
3.46
3.97
4.38
3.72
4.10
D room
Total capacity (kW)
Rated (Min._ Max.)
Total power consumption (W)
Rated (Min._ Max.)
Total current (A)
Rated (Min._ Max.)
7.50 (2.61–8.86)
7.50 (2.29–8.23)
7.50 (2.48–8.63)
7.50 (2.60–8.84)
7.50 (2.74–9.01)
7.50 (2.70–8.92)
7.50 (2.78–9.04)
7.50 (2.41–8.53)
7.50 (2.60–8.84)
7.50 (2.72–8.98)
7.50 (2.78–9.07)
2.00 (1.94–2.98)
2.50 (2.01–3.49)
3.50 (2.06–4.80)
5.00 (2.23–5.37)
6.00 (2.34–6.49)
7.10 (2.46–7.23)
4.00 (2.12–5.30)
4.50 (2.17–5.73)
5.50 (2.28–6.31)
7.00 (2.45–7.17)
7.36 (2.59–7.77)
7.67 (2.75–8.22)
5.00 (2.23–6.05)
6.00 (2.34–6.49)
7.21 (2.52–7.48)
7.50 (2.67–8.03)
7.81 (2.83–8.22)
7.00 (2.45–7.17)
7.50 (2.67–8.01)
7.79 (2.81–8.21)
7.95 (2.98–8.35)
7.90 (2.89–8.74)
8.21 (3.04–8.79)
8.53 (3.20–8.99)
8.50 (3.18–9.00)
8.55 (3.35–9.02)
8.66 (3.51–9.04)
6.00 (2.34–6.63)
6.50 (2.39–6.84)
7.21 (2.52–7.48)
7.64 (2.74–8.30)
7.93 (2.89–8.74)
8.24 (3.05–9.03)
7.00 (2.45–7.17)
7.36 (2.59–7.77)
7.79 (2.81–8.53)
8.07 (2.96–8.84)
8.39 (3.12–9.03)
7.64 (2.74–8.23)
8.07 (2.96–8.81)
8.36 (3.11–9.02)
8.67 (3.27–9.04)
8.50 (3.18–9.40)
8.79 (3.33–9.61)
9.00 (3.49–9.63)
9.00 (3.48–9.64)
9.00 (3.64–9.80)
7.20 (2.52–7.48)
7.50 (2.67–8.04)
7.93 (2.89–8.74)
8.21 (3.04–8.84)
8.53 (3.20–9.03)
7.79 (2.81–8.23)
8.21 (3.04–8.81)
8.50 (3.18–9.02)
8.81 (3.35–9.04)
8.64 (3.26–9.52)
8.93 (3.40–9.61)
9.00 (3.57–9.63)
9.00 (3.55–9.64)
9.00 (3.71–9.80)
2,240 (510–3,020)
2,580 (450–3,070)
2,360 (480–3,070)
2,260 (510–2,960)
2,220 (530–3,130)
2,130 (500–3,030)
2,080 (560–3,090)
2,560 (480–3,150)
2,360 (510–3,230)
2,210 (530–3,040)
2,130 (560–3,140)
560 (460–1,000)
700 (490–1,150)
1,120 (490–1,900)
1,520 (500–1,700)
1,880 (470–2,180)
2,540 (500–2,650)
1,120 (500–1,840)
1,270 (470–1,930)
1,700 (470–2,130)
2,210 (510–2,320)
2,430 (540–2,660)
2,610 (570–2,960)
1,390 (470–1,930)
1,880 (470–2,180)
2,320 (510–2,490)
2,490 (540–2,840)
2,720 (570–2,960)
2,490 (500–2,600)
2,540 (540–2,840)
2,720 (570–2,960)
2,780 (600–3,100)
2,480 (580–3,040)
2,660 (610–3,040)
2,850 (640–3,180)
2,850 (640–3,180)
2,790 (670–3,180)
2,790 (710–3,180)
1,670 (510–1,960)
1,910 (480–2,110)
2,320 (510–2,490)
2,310 (550–2,720)
2,490 (580–2,980)
2,670 (610–3,180)
2,220 (510–2,270)
2,440 (540–2,660)
2,370 (580–2,850)
2,550 (580–3,050)
2,730 (610–3,180)
2,610 (570–2,960)
2,540 (580–3,040)
2,730 (610–3,180)
2,920 (640–3,180)
2,530 (610–3,190)
2,660 (640–3,270)
2,730 (670–3,270)
2,730 (670–3,270)
2,670 (710–3,420)
2,320 (510–2,490)
2,490 (540–2,840)
2,480 (580–3,040)
2,670 (610–3,050)
2,860 (640–3,180)
2,660 (570–2,960)
2,660 (610–3,040)
2,850 (640–3,180)
3,050 (670–3,180)
2,660 (640–3,260)
2,790 (640–3,270)
2,790 (670–3,270)
2,790 (670–3,270)
2,730 (710–3,420)
9.4 (2.1–12.7)
10.9 (1.9–12.9)
9.9 (2.0–12.9)
9.5 (2.1–12.5)
9.3 (2.2–13.2)
9.0 (2.1–12.8)
8.8 (2.4–13.0)
10.8 (2.0–13.3)
9.9 (2.1–13.6)
9.3 (2.2–12.8)
9.0 (2.4–13.2)
2.4 (2.0– 4.3)
3.0 (2.1– 4.9)
4.8 (2.1– 8.1)
6.5 (2.1– 7.2)
8.0 (2.0– 9.3)
10.8 (2.1–11.3)
4.8 (2.1– 7.8)
5.4 (2.0– 8.2)
7.2 (2.0– 9.1)
9.4 (2.2– 9.9)
10.3 (2.3–11.3)
11.1 (2.4–12.6)
5.9 (2.0– 8.2)
8.0 (2.0– 9.3)
9.9 (2.2–10.6)
10.6 (2.3–12.1)
11.6 (2.4–12.6)
10.6 (2.1–11.1)
10.8 (2.3–12.1)
11.6 (2.4–12.6)
11.8 (2.6–13.2)
10.5 (2.5–12.9)
11.3 (2.6–12.9)
12.1 (2.7–13.5)
12.1 (2.7–13.5)
11.9 (2.8–13.5)
11.9 (3.0–13.5)
7.1 (2.2– 8.3)
8.1 (2.0– 9.0)
9.9 (2.2–10.6)
9.8 (2.3–11.6)
10.6 (2.5–12.7)
11.4 (2.6–13.5)
9.4 (2.2– 9.7)
10.4 (2.3–11.3)
10.1 (2.5–12.1)
10.8 (2.5–13.0)
11.6 (2.6–13.5)
11.1 (2.4–12.6)
10.8 (2.5–12.9)
11.6 (2.6–13.5)
12.4 (2.7–13.5)
10.8 (2.6–13.6)
11.3 (2.7–13.9)
11.6 (2.8–13.9)
11.6 (2.8–13.9)
11.4 (3.0–14.5)
9.9 (2.2–10.6)
10.6 (2.3–12.1)
10.5 (2.5–12.9)
11.4 (2.6–13.0)
12.2 (2.7–13.5)
11.3 (2.4–12.6)
11.3 (2.6–12.9)
12.1 (2.7–13.5)
13.0 (2.8–13.5)
11.3 (2.7–13.9)
11.9 (2.7–13.9)
11.9 (2.8–13.9)
11.9 (2.8–13.9)
11.6 (3.0–14.5)
28
Capacity tables
Capacity tables
Heat pump type
Outdoor
unit
Combinations
of indoor units
4MKS90EVMA
35+35+35
35+35+50
35+35+60
35+35+71
35+50+50
35+50+60
35+50+71
35+60+60
50+50+50
20+20+20+20
20+20+20+25
20+20+20+35
20+20+20+50
20+20+20+60
20+20+20+71
20+20+25+25
20+20+25+35
20+20+25+50
20+20+25+60
20+20+25+71
20+20+35+35
20+20+35+50
20+20+35+60
20+20+35+71
20+20+50+50
20+20+50+60
20+25+25+25
20+25+25+35
20+25+25+50
20+25+25+60
20+25+25+71
20+25+35+35
20+25+35+50
20+25+35+60
20+25+35+71
20+25+50+50
20+25+50+60
20+35+35+35
20+35+35+50
20+35+35+60
20+35+50+50
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+25+71
25+25+35+35
25+25+35+50
25+25+35+60
25+25+35+71
25+25+50+50
25+35+35+35
25+35+35+50
25+35+35+60
35+35+35+35
35+35+35+50
Capacity of each indoor unit (kW)
A room
2.69
2.48
2.37
2.22
2.31
2.18
2.02
2.04
3.00
1.84
1.76
1.64
1.49
1.42
1.35
1.70
1.59
1.45
1.38
1.32
1.49
1.38
1.32
1.23
1.29
1.20
1.64
1.54
1.42
1.35
1.28
1.45
1.35
1.29
1.19
1.24
1.17
1.38
1.29
1.20
1.16
1.98
1.87
1.73
1.65
1.54
1.77
1.65
1.55
1.44
1.50
1.68
1.55
1.45
2.24
2.03
B room
2.69
2.48
2.37
2.22
3.31
3.10
2.88
3.48
3.00
1.84
1.76
1.64
1.49
1.42
1.35
1.70
1.59
1.45
1.38
1.32
1.49
1.38
1.32
1.23
1.29
1.20
2.05
1.92
1.77
1.69
1.60
1.83
1.69
1.61
1.49
1.56
1.45
2.42
2.25
2.10
2.04
1.98
1.87
1.73
1.65
1.54
1.77
1.65
1.55
1.44
1.50
2.37
2.17
2.03
2.24
2.03
C room
2.69
3.54
4.05
4.51
3.31
3.72
4.10
3.48
3.00
1.84
1.76
1.64
1.49
1.42
1.35
2.12
1.98
1.82
1.73
1.65
2.61
2.42
2.32
2.16
3.21
3.00
2.05
1.92
1.77
1.69
1.60
2.54
2.37
2.25
2.09
3.10
2.90
2.42
2.25
2.10
2.90
1.98
1.87
1.73
1.65
1.54
2.48
2.32
2.17
2.02
3.00
2.37
2.17
2.03
2.24
2.03
D room
1.84
2.22
2.87
3.74
4.24
4.76
2.12
2.77
3.64
4.15
4.67
2.61
3.46
3.97
4.38
3.21
3.60
2.05
2.69
3.54
4.06
4.52
2.54
3.38
3.85
4.23
3.10
3.48
2.42
3.21
3.60
2.90
1.98
2.60
3.45
3.98
4.38
2.48
3.31
3.73
4.10
3.00
2.37
3.11
3.49
2.24
2.91
Total capacity (kW)
Rated (Min._ Max.)
Total power consumption (W)
Rated (Min._ Max.)
Total current (A)
Rated (Min._ Max.)
8.07 (2.96–8.41)
8.50 (3.18–8.99)
8.79 (3.33–9.03)
8.95 (3.49–9.05)
8.93 (3.40–9.58)
9.00 (3.55–9.62)
9.00 (3.71–9.80)
9.00 (3.70–9.80)
9.00 (3.63–9.80)
7.36 (2.59–7.77)
7.50 (2.67–8.04)
7.79 (2.81–8.53)
8.21 (3.04–9.11)
8.50 (3.18–9.40)
8.81 (3.35–9.63)
7.64 (2.74–8.30)
7.93 (2.89–8.74)
8.36 (3.11–9.27)
8.64 (3.26–9.52)
8.96 (3.42–9.68)
8.20 (3.04–8.86)
8.64 (3.26–9.52)
8.93 (3.40–9.66)
9.00 (3.57–9.68)
9.00 (3.48–9.75)
9.00 (3.63–9.80)
7.79 (2.81–8.53)
8.07 (2.96–8.86)
8.50 (3.18–9.40)
8.79 (3.33–9.61)
9.00 (3.49–9.68)
8.36 (3.11–9.04)
8.79 (3.33–9.61)
9.00 (3.48–9.66)
9.00 (3.64–9.80)
9.00 (3.55–9.78)
9.00 (3.70–9.80)
8.64 (3.26–9.05)
9.00 (3.48–9.63)
9.00 (3.63–9.80)
9.00 (3.70–9.80)
7.92 (2.89–8.74)
8.21 (3.04–8.86)
8.64 (3.26–9.52)
8.93 (3.40–9.65)
9.00 (3.57–9.68)
8.50 (3.18–9.04)
8.93 (3.40–9.63)
9.00 (3.55–9.66)
9.00 (3.71–9.80)
9.00 (3.63–9.80)
8.79 (3.33–9.07)
9.00 (3.55–9.63)
9.00 (3.70–9.80)
8.96 (3.48–9.05)
9.00 (3.70–9.80)
2,900 (600–3,150)
2,850 (640–3,180)
2,980 (670–3,180)
2,990 (710–3,190)
2,850 (640–3,260)
2,860 (670–3,270)
2,790 (710–3,420)
2,790 (710–3,420)
2,580 (680–3,130)
1,980 (520–2,200)
2,090 (550–2,370)
2,200 (580–2,670)
2,350 (580–2,920)
2,480 (610–3,130)
2,670 (640–3,280)
2,140 (550–2,550)
2,430 (580–2,980)
2,410 (610–3,060)
2,600 (640–3,200)
2,800 (640–3,280)
2,610 (610–3,050)
2,600 (640–3,200)
2,730 (640–3,280)
2,670 (670–3,280)
2,520 (640–3,060)
2,520 (680–3,070)
2,260 (580–2,670)
2,550 (580–3,050)
2,540 (610–3,130)
2,600 (640–3,280)
2,670 (670–3,280)
2,730 (610–3,180)
2,730 (640–3,270)
2,730 (670–3,280)
2,670 (710–3,430)
2,520 (640–3,060)
2,520 (680–3,070)
2,920 (640–3,190)
2,860 (670–3,270)
2,730 (710–3,420)
2,520 (680–3,070)
2,430 (580–2,980)
2,610 (610–3,050)
2,600 (640–3,200)
2,730 (640–3,280)
2,670 (670–3,280)
2,790 (640–3,180)
2,790 (640–3,270)
2,730 (670–3,280)
2,670 (710–3,430)
2,520 (680–3,060)
3,050 (670–3,190)
2,860 (670–3,270)
2,730 (710–3,420)
3,120 (710–3,220)
2,860 (710–3,420)
12.3 (2.6–13.4)
12.1 (2.7–13.5)
12.7 (2.8–13.5)
13.9 (3.3–14.8)
13.2 (3.0–15.1)
13.3 (3.1–15.2)
12.9 (3.3–15.9)
12.9 (3.3–15.9)
12.0 (3.2–14.5)
9.2 (2.4–10.2)
9.7 (2.6–11.0)
10.2 (2.7–12.4)
10.9 (2.7–13.5)
11.5 (2.8–14.5)
12.4 (3.0–15.2)
9.9 (2.6–11.8)
11.3 (2.7–13.8)
11.2 (2.8–14.2)
12.1 (3.0–14.8)
13.0 (3.0–15.2)
12.1 (2.8–14.1)
12.1 (3.0–14.8)
12.7 (3.0–15.2)
12.4 (3.1–15.2)
11.7 (3.0–14.2)
11.7 (3.2–14.2)
10.5 (2.7–12.4)
11.8 (2.7–14.1)
11.8 (2.8–14.5)
12.1 (3.0–15.2)
12.4 (3.1–15.2)
12.7 (2.8–14.7)
12.7 (3.0–15.2)
12.7 (3.1–15.2)
12.4 (3.3–15.9)
11.7 (3.0–14.2)
11.7 (3.2–14.2)
13.5 (3.0–14.8)
13.3 (3.1–15.2)
11.6 (3.0–14.5)
10.7 (2.9–13.1)
10.3 (2.5–12.7)
11.1 (2.6–13.0)
11.1 (2.7–13.6)
11.6 (2.7–13.9)
11.4 (2.8–13.9)
11.9 (2.7–13.5)
11.9 (2.7–13.9)
11.6 (2.8–13.9)
11.4 (3.0–14.6)
10.7 (2.9–13.0)
13.0 (2.8–13.6)
12.2 (2.8–13.9)
11.6 (3.0–14.5)
13.3 (3.0–13.7)
12.2 (3.0–14.5)
Notes: 1. Cooling operation data is based on the following conditions: indoor temp. 27 ˚CDB, 19 ˚CWB; outdoor temp. 35 ˚CDB.
2. Total capacity of connected indoor units is: up to 10.0 kW to the 3MKS58E; up to 13.5 kW to the 3MKS75E; up to 15.6 kW to the 4MKS90E.
29
Outdoor
unit
3MXS52EVMA
Cooling
capacity
3MXS52EVMA
Heating
capacity
3MXS68EVMA
Cooling
capacity
Combinations
of indoor units
20
25
35
50
20+20
20+25
20+35
20+50
25+25
25+35
25+50
35+35
35+50
20+20+20
20+20+25
20+20+35
20+25+25
20+25+35
20+35+35
25+25+25
25+25+35
20+20+50
20
25
35
50
20+20
20+25
20+35
20+50
25+25
25+35
25+50
35+35
35+50
20+20+20
20+20+25
20+20+35
20+25+25
20+25+35
20+35+35
25+25+25
25+25+35
20+20+50
20
25
35
50
60
20+20
20+25
20+35
20+50
20+60
25+25
25+35
25+50
25+60
35+35
35+50
35+60
50+50
50+60
20+20+20
20+20+25
20+20+35
20+20+50
20+20+60
20+25+25
20+25+35
20+25+50
20+25+60
20+35+35
240 V, 50 Hz
Capacity of each indoor unit (kW)
A room
2.00
2.50
3.50
5.00
2.00
2.00
1.89
1.49
2.50
2.17
1.73
2.60
2.14
1.73
1.60
1.38
1.49
1.30
1.16
1.73
1.53
1.16
2.72
3.40
4.20
5.80
3.05
2.78
2.38
1.94
3.25
2.79
2.27
3.40
2.80
2.26
2.09
1.80
1.94
1.70
1.52
2.26
2.00
1.51
2.00
2.50
3.50
5.00
6.00
2.00
2.00
2.00
1.94
1.70
2.50
2.50
2.27
2.00
3.40
2.80
2.51
3.40
3.09
2.00
2.00
1.81
1.51
1.36
1.94
1.70
1.43
1.30
1.52
B room
C room
2.00
2.50
3.31
3.71
2.50
3.03
3.47
2.60
3.06
1.73
1.60
1.38
1.85
1.63
2.02
1.73
1.53
1.16
1.73
1.99
2.43
1.85
2.27
2.02
1.73
2.14
2.88
3.05
3.47
4.17
4.86
3.25
3.97
4.53
3.40
4.00
2.26
2.09
1.80
2.42
2.13
2.64
2.26
2.00
1.51
2.26
2.60
3.18
2.42
2.97
2.64
2.26
2.80
3.78
2.00
2.50
3.50
4.86
5.10
2.50
3.50
4.53
4.80
3.40
4.00
4.29
3.40
3.71
2.00
2.00
1.81
1.51
1.36
2.43
2.13
1.79
1.62
2.64
2.00
2.50
3.18
3.78
4.08
2.43
2.97
3.58
3.88
2.64
D room
Total capacity (kW)
Rated (Min._ Max.)
Total power consumption (W)
Rated (Min._ Max.)
Total current (A)
Rated (Min._ Max.)
2.00 (1.76–2.84)
2.50 (1.76–3.24)
3.50 (1.76–4.52)
5.00 (1.85–5.80)
4.00 (1.88–5.96)
4.50 (1.88–6.23)
5.20 (1.88–6.24)
5.20 (1.88–6.91)
5.00 (1.88–6.23)
5.20 (1.88–6.35)
5.20 (1.88–6.91)
5.20 (1.88–6.40)
5.20 (1.88–6.92)
5.19 (1.86–7.04)
5.19 (1.86–7.04)
5.19 (1.95–7.06)
5.19 (1.86–7.04)
5.20 (1.95–7.06)
5.20 (1.95–7.07)
5.19 (1.95–7.04)
5.20 (1.95–7.06)
5.20 (2.04–7.30)
2.72 (1.21–3.75)
3.40 (1.21–4.00)
4.20 (1.21–4.82)
5.80 (1.30–6.79)
6.10 (1.28–7.00)
6.25 (1.28–7.00)
6.55 (1.34–7.04)
6.80 (1.36–7.95)
6.50 (1.28–7.00)
6.70 (1.34–7.19)
6.80 (1.42–7.95)
6.80 (1.40–7.22)
6.80 (1.42–7.98)
6.78 (1.34–8.02)
6.78 (1.34–8.02)
6.78 (1.45–8.05)
6.78 (1.34–8.02)
6.80 (1.57–8.05)
6.80 (1.56–8.08)
6.78 (1.45–8.02)
6.80 (1.57–8.05)
6.80 (1.64–8.30)
2.00 (1.63–2.57)
2.50 (1.70–3.39)
3.50 (1.71–4.73)
5.00 (1.87–5.88)
6.00 (1.89–6.35)
4.00 (1.82–5.02)
4.50 (1.83–5.31)
5.50 (1.92–6.20)
6.80 (1.99–7.10)
6.80 (2.12–7.58)
5.00 (1.83–5.97)
6.00 (1.90–6.43)
6.80 (2.10–7.25)
6.80 (2.15–7.60)
6.80 (1.98–6.97)
6.80 (2.15–7.63)
6.80 (2.25–7.90)
6.80 (2.36–8.11)
6.80 (2.42–8.29)
6.00 (1.92–6.45)
6.50 (1.93–6.85)
6.80 (2.04–7.21)
6.80 (2.23–7.90)
6.80 (2.36–8.15)
6.80 (2.04–7.10)
6.80 (2.15–7.58)
6.80 (2.23–7.93)
6.80 (2.36–8.37)
6.80 (2.15–7.88)
460 (350– 740)
620 (350– 800)
970 (350–1,510)
1,540 (350–2,100)
950 (350–1,910)
1,180 (350–2,140)
1,550 (350–2,140)
1,280 (350–2,070)
1,450 (350–2,140)
1,550 (350–2,250)
1,280 (350–2,070)
1,550 (350–2,250)
1,260 (350–2,080)
1,240 (350–2,160)
1,240 (350–2,160)
1,240 (370–2,160)
1,240 (350–2,160)
1,240 (370–2,160)
1,240 (370–2,160)
1,240 (370–2,160)
1,230 (370–2,160)
1,220 (390–2,190)
720 (300–1,200)
990 (300–1,260)
1,390 (300–1,680)
1,740 (300–2,510)
1,700 (310–2,280)
1,750 (310–2,280)
1,860 (310–2,280)
1,520 (310–2,220)
1,860 (310–2,310)
1,930 (310–2,360)
1,520 (310–2,220)
1,970 (310–2,350)
1,520 (310–2,210)
1,570 (320–2,140)
1,570 (320–2,140)
1,560 (320–2,140)
1,570 (320–2,140)
1,560 (320–2,140)
1,560 (320–2,140)
1,570 (320–2,140)
1,560 (320–2,140)
1,420 (320–2,040)
490 (400– 670)
650 (440– 910)
1,020 (450–1,430)
1,650 (470–2,140)
2,230 (450–2,440)
1,100 (430–1,590)
1,340 (440–1,750)
1,860 (450–2,380)
2,440 (460–2,510)
2,390 (480–2,760)
1,710 (460–2,190)
2,430 (460–2,630)
2,440 (470–2,640)
2,390 (470–2,840)
2,770 (450–2,850)
2,440 (470–2,870)
2,370 (470–3,110)
2,190 (490–2,950)
2,140 (490–3,060)
1,760 (450–1,950)
2,070 (450–2,180)
2,260 (470–2,470)
2,100 (480–2,690)
2,050 (500–2,820)
2,280 (470–2,380)
2,230 (470–2,680)
2,100 (480–2,690)
2,040 (500–3,010)
2,230 (480–2,990)
2.0 (1.5– 3.2)
2.7 (1.5– 3.4)
4.1 (1.5– 6.4)
6.5 (1.5– 8.8)
4.0 (1.5– 8.0)
5.0 (1.5– 9.0)
6.5 (1.5– 9.0)
5.4 (1.5– 8.7)
6.1 (1.5– 9.0)
6.5 (1.5– 9.5)
5.4 (1.5– 8.7)
6.5 (1.5– 9.5)
5.3 (1.5– 8.8)
5.2 (1.5– 9.1)
5.2 (1.5– 9.1)
5.2 (1.6– 9.1)
5.2 (1.5– 9.1)
5.2 (1.6– 9.1)
5.2 (1.6– 9.1)
5.2 (1.6– 9.1)
5.2 (1.6– 9.1)
5.1 (1.6– 9.2)
3.1 (1.3– 5.2)
4.3 (1.3– 5.4)
5.9 (1.3– 7.1)
7.3 (1.3–10.6)
7.2 (1.3– 9.6)
7.4 (1.3– 9.6)
7.8 (1.3– 9.6)
6.4 (1.3– 9.3)
7.8 (1.3– 9.7)
8.1 (1.3– 9.9)
6.4 (1.3– 9.3)
8.3 (1.3– 9.9)
6.4 (1.3– 9.3)
6.6 (1.3– 9.0)
6.6 (1.3– 9.0)
6.6 (1.3– 9.0)
6.6 (1.3– 9.0)
6.6 (1.3– 9.0)
6.6 (1.3– 9.0)
6.6 (1.3– 9.0)
6.6 (1.3– 9.0)
6.0 (1.3– 8.6)
2.1 (1.7– 2.9)
2.8 (1.9– 3.9)
4.3 (1.9– 6.1)
6.9 (2.0– 9.0)
9.4 (1.9–10.3)
4.6 (1.8– 6.7)
5.6 (1.9– 7.4)
7.8 (1.9–10.0)
10.3 (1.9–10.6)
10.1 (2.0–11.6)
7.2 (1.9– 9.2)
10.2 (1.9–11.1)
10.3 (2.0–11.1)
10.1 (2.0–12.0)
11.7 (1.9–12.0)
10.3 (2.0–12.1)
10.0 (2.0–13.1)
9.2 (2.1–12.4)
9.0 (2.1–12.9)
7.4 (1.9– 8.2)
8.7 (1.9– 9.2)
9.5 (2.0–10.4)
8.8 (2.0–11.3)
8.6 (2.1–11.9)
9.6 (2.0–10.0)
9.4 (2.0–11.3)
8.8 (2.0–11.3)
8.6 (2.1–12.7)
9.4 (2.0–12.6)
30
Capacity tables
Outdoor
unit
3MXS68EVMA
Cooling
capacity
3MXS68EVMA
Heating
capacity
4MXS80EVMA
Cooling
capacity
31
Combinations
of indoor units
20+35+50
25+25+25
25+25+35
25+25+50
25+25+60
25+35+35
25+35+50
35+35+35
20
25
35
50
60
20+20
20+25
20+35
20+50
20+60
25+25
25+35
25+50
25+60
35+35
35+50
35+60
50+50
50+60
20+20+20
20+20+25
20+20+35
20+20+50
20+20+60
20+25+25
20+25+35
20+25+50
20+25+60
20+35+35
20+35+50
25+25+25
25+25+35
25+25+50
25+25+60
25+35+35
25+35+50
35+35+35
20
25
35
50
60
71
20+20
20+25
20+35
20+50
20+60
20+71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
71+71
20+20+20
Capacity tables
Capacity of each indoor unit (kW)
A room
1.30
2.26
2.00
1.70
1.55
1.78
1.55
2.26
2.72
3.40
4.30
7.20
7.90
3.25
3.04
2.71
2.46
2.15
3.60
3.29
2.87
2.53
4.30
3.54
3.17
4.30
3.91
2.63
2.54
2.29
1.91
1.72
2.46
2.15
1.81
1.64
1.92
1.64
2.86
2.53
2.15
1.95
2.26
1.95
2.86
2.00
2.50
3.50
5.00
6.00
7.10
2.00
2.00
2.00
2.00
1.83
1.66
2.50
2.50
2.40
2.18
2.00
3.50
3.06
2.82
2.61
3.88
3.64
3.31
4.00
3.66
4.00
2.00
B room
2.27
2.26
2.00
1.70
1.55
2.51
2.16
2.26
C room
3.23
2.26
2.80
3.40
3.70
2.51
3.09
2.26
3.25
3.81
4.74
6.14
6.45
3.60
4.61
5.73
6.07
4.30
5.06
5.43
4.30
4.69
2.63
2.54
2.29
1.91
1.72
3.07
2.69
2.26
2.05
3.34
2.87
2.86
2.53
2.15
1.95
3.17
2.74
2.86
2.63
3.17
4.02
4.78
5.16
3.07
3.76
4.53
4.91
3.34
4.09
2.86
3.54
4.30
4.70
3.17
3.91
2.86
2.00
2.50
3.50
5.00
5.48
5.90
2.50
3.50
4.79
5.24
5.68
3.50
4.36
4.83
5.30
3.88
4.36
4.69
4.00
4.34
4.00
2.00
2.00
D room
Total capacity (kW)
Rated (Min._ Max.)
Total power consumption (W)
Rated (Min._ Max.)
Total current (A)
Rated (Min._ Max.)
6.80 (2.36– 8.37)
6.80 (2.04– 7.45)
6.80 (2.15– 7.79)
6.80 (2.35– 8.27)
6.80 (2.42– 8.53)
6.80 (2.25– 8.11)
6.80 (2.42– 8.53)
6.80 (2.37– 8.44)
2.72 (1.22– 3.88)
3.40 (1.23– 4.11)
4.30 (1.29– 4.47)
7.20 (1.61– 8.02)
7.90 (1.93– 8.51)
6.50 (1.61– 7.65)
6.85 (1.61– 7.82)
7.45 (1.75– 8.35)
8.60 (2.15–10.12)
8.60 (2.43–10.32)
7.20 (1.61– 8.14)
7.90 (1.90– 8.62)
8.60 (2.26–10.23)
8.60 (2.53–10.40)
8.60 (2.13– 8.97)
8.60 (2.50–10.41)
8.60 (2.73–10.56)
8.60 (2.83–10.61)
8.60 (3.04–10.64)
7.89 (1.89–10.03)
8.25 (2.02–10.12)
8.60 (2.27–10.20)
8.60 (2.67–10.47)
8.60 (2.81–10.60)
8.60 (2.15–10.12)
8.60 (2.36–10.20)
8.60 (2.70–10.61)
8.60 (2.93–10.64)
8.60 (2.68–10.41)
8.60 (3.02–10.64)
8.60 (2.26–10.23)
8.60 (2.50–10.41)
8.60 (2.83–10.61)
8.60 (3.04–10.64)
8.60 (2.73–10.56)
8.60 (3.04–10.64)
8.60 (3.01–10.62)
2.00 (1.80– 2.99)
2.50 (1.87– 3.52)
3.50 (1.91– 4.85)
5.00 (2.07– 5.65)
6.00 (2.17– 6.60)
7.10 (2.28– 7.26)
4.00 (1.97– 5.30)
4.50 (2.02– 5.73)
5.50 (2.12– 6.38)
7.00 (2.27– 7.30)
7.31 (2.41– 7.90)
7.56 (2.56– 8.22)
5.00 (2.07– 6.17)
6.00 (2.17– 6.60)
7.19 (2.34– 7.59)
7.42 (2.48– 8.03)
7.68 (2.63– 8.22)
7.00 (2.27– 7.27)
7.42 (2.48– 8.01)
7.65 (2.61– 8.54)
7.91 (2.77– 8.23)
7.76 (2.68– 8.76)
8.00 (2.82– 8.79)
8.00 (2.97– 8.99)
8.00 (2.96– 9.00)
8.00 (3.11– 9.02)
8.00 (3.26– 9.04)
6.00 (2.17– 6.63)
2,050 (490–3,120)
2,230 (470–2,580)
2,230 (470–2,860)
2,050 (500–2,960)
2,030 (490–3,180)
2,230 (470–3,200)
2,050 (490–3,250)
2,210 (470–3,330)
790 (370–1,230)
1,090 (370–1,330)
1,410 (380–1,560)
2,420 (400–2,710)
2,510 (430–2,710)
1,830 (400–2,200)
2,010 (400–2,290)
2,280 (410–2,570)
2,420 (490–2,890)
2,310 (540–2,920)
2,200 (400–2,500)
2,560 (430–2,800)
2,420 (510–2,930)
2,310 (570–2,930)
2,870 (480–3,030)
2,410 (570–3,010)
2,280 (590–2,920)
2,240 (650–2,800)
2,150 (640–2,740)
2,010 (440–2,640)
2,120 (470–2,680)
2,300 (500–2,800)
2,130 (610–2,620)
2,080 (600–2,610)
2,300 (480–2,730)
2,290 (520–2,800)
2,080 (610–2,650)
2,060 (630–2,570)
2,270 (590–2,840)
2,080 (670–2,720)
2,300 (500–2,800)
2,290 (540–2,880)
2,080 (650–2,680)
2,040 (660–2,580)
2,270 (580–2,880)
2,080 (680–2,670)
2,250 (670–2,940)
600 (460–1,070)
780 (490–1,350)
1,190 (490–1,570)
1,670 (470–1,810)
2,010 (470–2,430)
2,710 (500–2,830)
1,190 (470–1,670)
1,360 (470–1,810)
1,810 (470–2,110)
2,360 (510–2,530)
2,530 (510–2,960)
2,690 (540–3,160)
1,440 (430–2,110)
2,010 (470–2,370)
2,470 (510–2,770)
2,590 (540–3,030)
2,730 (580–3,160)
2,650 (500–2,830)
2,650 (540–3,030)
2,700 (580–3,560)
2,970 (610–3,160)
2,580 (580–3,240)
2,710 (610–3,250)
2,710 (650–3,390)
2,650 (610–3,390)
2,590 (650–3,390)
2,530 (680–3,400)
1,780 (510–2,090)
8.6 (2.1–13.1)
9.4 (2.0–10.9)
9.4 (2.0–12.0)
8.6 (2.1–12.5)
8.5 (2.1–13.4)
9.4 (2.0–13.5)
8.6 (2.1–13.7)
9.3 (2.0–14.0)
3.4 (1.6– 5.2)
4.6 (1.6– 5.7)
5.9 (1.6– 6.6)
10.2 (1.7–11.4)
10.6 (1.8–11.4)
7.7 (1.7– 9.3)
8.5 (1.7– 9.6)
9.6 (1.7–10.8)
10.2 (2.1–12.2)
9.7 (2.3–12.3)
9.3 (1.7–10.5)
10.8 (1.8–11.8)
10.2 (2.1–12.3)
9.7 (2.4–12.3)
12.1 (2.0–12.8)
10.1 (2.4–12.7)
9.6 (2.5–12.3)
9.4 (2.7–11.8)
9.0 (2.7–11.5)
8.5 (1.9–11.1)
8.9 (2.0–11.3)
9.7 (2.1–11.8)
9.0 (2.6–11.0)
8.8 (2.5–11.0)
9.7 (2.0–11.5)
9.6 (2.2–11.8)
8.8 (2.6–11.2)
8.7 (2.7–10.8)
9.6 (2.5–12.0)
8.8 (2.8–11.4)
9.7 (2.1–11.8)
9.6 (2.3–12.1)
8.8 (2.7–11.3)
8.6 (2.8–10.9)
9.6 (2.4–12.1)
8.8 (2.9–11.2)
9.5 (2.8–12.4)
2.6 (2.0– 4.5)
3.3 (2.1– 5.7)
5.1 (2.1– 6.7)
7.1 (2.0– 7.7)
8.5 (2.0–10.3)
11.5 (2.1–12.0)
5.1 (2.0– 7.1)
5.8 (2.0– 7.7)
7.7 (2.0– 9.0)
10.0 (2.2–10.8)
10.8 (2.2–12.6)
11.4 (2.3–13.4)
6.1 (1.8– 9.0)
8.5 (2.0–10.1)
10.5 (2.2–11.8)
11.0 (2.3–12.9)
11.6 (2.5–13.4)
11.3 (2.1–12.0)
11.3 (2.3–12.9)
11.5 (2.5–15.1)
12.6 (2.6–13.4)
11.0 (2.5–13.8)
11.5 (2.6–13.8)
11.5 (2.8–14.4)
11.3 (2.6–14.4)
11.0 (2.8–14.4)
10.8 (2.9–14.5)
7.6 (2.2– 8.9)
Outdoor
unit
4MXS80EVMA
Cooling
capacity
Combinations
of indoor units
20+20+25
20+20+35
20+20+50
20+20+60
20+20+71
20+25+25
20+25+35
20+25+50
20+25+60
20+25+71
20+35+35
20+35+50
20+35+60
20+35+71
20+50+50
20+50+60
20+50+71
20+60+60
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
25+60+60
35+35+35
35+35+50
35+35+60
35+35+71
35+50+50
35+50+60
20+20+20+20
20+20+20+25
20+20+20+35
20+20+20+50
20+20+20+60
20+20+20+71
20+20+25+25
20+20+25+35
20+20+25+50
20+20+25+60
20+20+25+71
20+20+35+35
20+20+35+50
20+20+35+60
20+20+50+50
20+25+25+25
20+25+25+35
20+25+25+50
20+25+25+60
20+25+25+71
20+25+35+35
20+25+35+50
20+25+35+60
20+25+50+50
20+35+35+35
20+35+35+50
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+50
25+25+35+60
25+35+35+35
25+35+35+50
35+35+35+35
Capacity of each indoor unit (kW)
A room
2.00
1.92
1.68
1.55
1.44
2.00
1.83
1.61
1.50
1.38
1.68
1.50
1.39
1.27
1.34
1.23
1.13
1.14
2.40
2.18
1.94
1.82
1.65
2.01
1.81
1.67
1.52
1.60
1.48
1.38
2.63
2.33
2.15
1.99
2.08
1.93
1.83
1.75
1.61
1.45
1.33
1.22
1.68
1.55
1.39
1.28
1.18
1.45
1.28
1.19
1.14
1.62
1.50
1.33
1.23
1.13
1.40
1.23
1.14
1.10
1.28
1.14
1.94
1.82
1.60
1.48
1.67
1.48
1.38
1.55
1.38
2.00
B room
2.00
1.92
1.68
1.55
1.44
2.50
2.28
2.01
1.88
1.72
2.93
2.63
2.43
2.22
3.33
3.08
2.84
3.43
2.40
2.18
1.94
1.82
1.65
2.82
2.55
2.33
2.14
3.20
2.96
3.31
2.63
2.33
2.15
1.99
2.96
2.76
1.83
1.75
1.61
1.45
1.33
1.22
1.68
1.55
1.39
1.28
1.18
1.45
1.28
1.19
1.14
2.01
1.88
1.67
1.54
1.42
1.74
1.54
1.43
1.38
2.24
2.00
1.94
1.82
1.60
1.48
1.67
1.48
1.38
2.15
1.93
2.00
C room
2.50
3.35
4.18
4.67
5.12
2.50
3.20
4.03
4.50
4.90
2.93
3.75
4.18
4.51
3.33
3.69
4.03
3.43
2.40
3.06
3.89
4.36
4.70
2.82
3.64
4.00
4.34
3.20
3.56
3.31
2.63
3.34
3.70
4.02
2.96
3.31
1.83
1.75
1.61
1.45
1.33
1.22
2.09
1.94
1.74
1.60
1.47
2.55
2.24
2.07
2.86
2.01
1.88
1.67
1.54
1.42
2.43
2.15
2.00
2.76
2.24
2.00
1.94
1.82
1.60
1.48
2.33
2.07
1.93
2.15
1.93
2.00
D room
1.83
2.17
2.82
3.65
4.01
4.34
2.09
2.73
3.48
3.84
4.17
2.55
3.20
3.55
2.86
2.01
2.62
3.33
3.69
4.03
2.43
3.08
3.43
2.76
2.24
2.86
1.94
2.54
3.20
3.56
2.33
2.97
3.31
2.15
2.76
2.00
Total capacity (kW)
Rated (Min._ Max.)
Total power consumption (W)
Rated (Min._ Max.)
Total current (A)
Rated (Min._ Max.)
6.50 (2.22–6.95)
7.19 (2.34–7.61)
7.54 (2.55–8.40)
7.77 (2.68–8.82)
8.00 (2.83–9.03)
7.00 (2.27–7.30)
7.31 (2.41–7.90)
7.65 (2.61–8.62)
7.88 (2.75–8.84)
8.00 (2.90–9.03)
7.54 (2.55–8.23)
7.88 (2.75–8.81)
8.00 (2.89–9.02)
8.00 (3.04–9.07)
8.00 (2.96–9.39)
8.00 (3.09–9.54)
8.00 (3.25–9.60)
8.00 (3.23–9.60)
7.20 (2.34–7.61)
7.42 (2.48–8.05)
7.77 (2.68–8.80)
8.00 (2.82–8.84)
8.00 (2.97–9.03)
7.65 (2.61–8.34)
8.00 (2.82–8.81)
8.00 (2.96–9.02)
8.00 (3.11–9.07)
8.00 (3.03–9.47)
8.00 (3.16–9.58)
8.00 (3.30–9.60)
7.89 (2.75–8.58)
8.00 (2.96–8.99)
8.00 (3.09–9.07)
8.00 (3.25–9.05)
8.00 (3.16–9.58)
8.00 (3.30–9.60)
7.32 (2.41–7.90)
7.42 (2.48–8.16)
7.65 (2.61–8.62)
8.00 (2.82–9.15)
8.00 (2.96–9.39)
8.00 (3.11–9.55)
7.54 (2.55–8.40)
7.77 (2.68–8.82)
8.00 (2.89–9.28)
8.00 (3.03–9.47)
8.00 (3.18–9.59)
8.00 (2.82–8.86)
8.00 (3.03–9.47)
8.00 (3.16–9.58)
8.00 (3.23–9.60)
7.65 (2.61–8.62)
7.88 (2.75–8.86)
8.00 (2.96–9.39)
8.00 (3.09–9.54)
8.00 (3.25–9.60)
8.00 (2.89–9.09)
8.00 (3.09–9.54)
8.00 (3.23–9.60)
8.00 (3.30–9.60)
8.00 (3.03–9.23)
8.00 (3.23–9.60)
7.76 (2.68–8.82)
8.00 (2.82–8.92)
8.00 (3.03–9.47)
8.00 (3.16–9.58)
8.00 (2.96–9.04)
8.00 (3.16–9.58)
8.00 (3.30–9.60)
8.00 (3.09–9.34)
8.00 (3.30–9.60)
8.00 (3.23–9.05)
2,030 (510–2,310)
2,480 (510–2,720)
2,400 (550–2,970)
2,530 (580–3,250)
2,650 (610–3,400)
2,360 (510–2,540)
2,540 (510–2,970)
2,460 (550–3,110)
2,590 (580–3,250)
2,650 (610–3,400)
2,720 (540–3,160)
2,580 (580–3,250)
2,590 (610–3,390)
2,530 (650–3,400)
2,380 (620–3,330)
2,320 (650–3,480)
2,260 (650–3,490)
2,380 (650–3,490)
2,480 (510–2,720)
2,600 (540–3,030)
2,520 (580–3,240)
2,650 (610–3,250)
2,590 (610–3,400)
2,780 (580–3,090)
2,710 (610–3,250)
2,650 (610–3,390)
2,590 (650–3,400)
2,380 (620–3,400)
2,320 (650–3,480)
2,260 (680–3,490)
2,900 (610–3,160)
2,710 (610–3,390)
2,650 (650–3,390)
2,590 (680–3,400)
2,380 (650–3,480)
2,320 (680–3,490)
2,110 (520–2,460)
2,170 (550–2,590)
2,290 (550–2,910)
2,380 (590–3,120)
2,320 (620–3,340)
2,260 (650–3,420)
2,230 (550–2,780)
2,530 (580–3,250)
2,380 (590–3,260)
2,320 (620–3,340)
2,260 (650–3,500)
2,650 (610–3,250)
2,380 (620–3,410)
2,320 (650–3,490)
2,150 (650–3,110)
2,290 (550–2,910)
2,590 (580–3,250)
2,380 (620–3,340)
2,350 (650–3,420)
2,320 (650–3,500)
2,650 (610–3,400)
2,380 (650–3,490)
2,320 (650–3,490)
2,110 (650–3,110)
2,650 (650–3,400)
2,380 (650–3,490)
2,530 (580–3,250)
2,650 (610–3,250)
2,380 (620–3,410)
2,320 (650–3,490)
2,650 (610–3,400)
2,380 (650–3,490)
2,320 (680–3,490)
2,650 (650–3,400)
2,380 (680–3,490)
2,650 (680–3,400)
8.6 (2.2– 9.8)
10.5 (2.2–11.6)
10.2 (2.3–12.6)
10.8 (2.5–13.8)
11.3 (2.6–14.5)
10.0 (2.2–10.8)
10.8 (2.2–12.6)
10.5 (2.3–13.2)
11.0 (2.5–13.8)
11.3 (2.6–14.5)
11.6 (2.3–13.4)
11.0 (2.5–13.8)
11.0 (2.6–14.4)
10.8 (2.8–14.5)
10.1 (2.6–14.2)
9.9 (2.8–14.8)
9.6 (2.8–14.8)
10.1 (2.8–14.8)
10.5 (2.2–11.6)
11.1 (2.3–12.9)
10.7 (2.5–13.8)
11.3 (2.6–13.8)
11.0 (2.6–14.5)
11.8 (2.5–13.1)
11.5 (2.6–13.8)
11.3 (2.6–14.4)
11.0 (2.8–14.5)
10.1 (2.6–14.5)
9.9 (2.8–14.8)
9.6 (2.9–14.8)
12.3 (2.6–13.4)
11.5 (2.6–14.4)
11.3 (2.8–14.4)
11.0 (2.9–14.5)
10.1 (2.8–14.8)
9.9 (2.9–14.8)
9.0 (2.2–10.5)
9.2 (2.3–11.0)
9.7 (2.3–12.4)
10.1 (2.5–13.3)
9.9 (2.6–14.2)
9.6 (2.8–14.5)
9.5 (2.3–11.8)
10.8 (2.5–13.8)
10.1 (2.5–13.9)
9.9 (2.6–14.2)
9.6 (2.8–14.9)
11.3 (2.6–13.8)
10.1 (2.6–14.5)
9.9 (2.8–14.8)
9.1 (2.8–13.2)
9.7 (2.3–12.4)
11.0 (2.5–13.8)
10.1 (2.6–14.2)
10.0 (2.8–14.5)
9.9 (2.8–14.9)
11.3 (2.6–14.5)
10.1 (2.8–14.8)
9.9 (2.8–14.8)
9.0 (2.8–13.2)
11.3 (2.8–14.5)
10.1 (2.8–14.8)
10.8 (2.5–13.8)
11.3 (2.6–13.8)
10.1 (2.6–14.5)
9.9 (2.8–14.8)
11.3 (2.6–14.5)
10.1 (2.8–14.8)
9.9 (2.9–14.8)
11.3 (2.8–14.5)
10.1 (2.9–14.8)
11.3 (2.9–14.5)
32
Capacity tables
Outdoor
unit
4MXS80EVMA
Heating
capacity
33
Combinations
of indoor units
20
25
35
50
60
71
20+20
20+25
20+35
20+50
20+60
20+71
25+25
25+35
25+50
25+60
25+71
35+35
35+50
35+60
35+71
50+50
50+60
50+71
60+60
60+71
71+71
20+20+20
20+20+25
20+20+35
20+20+50
20+20+60
20+20+71
20+25+25
20+25+35
20+25+50
20+25+60
20+25+71
20+35+35
20+35+50
20+35+60
20+35+71
20+50+50
20+50+60
20+50+71
20+60+60
25+25+25
25+25+35
25+25+50
25+25+60
25+25+71
25+35+35
25+35+50
25+35+60
25+35+71
25+50+50
25+50+60
25+60+60
35+35+35
35+35+50
35+35+60
35+35+71
35+50+50
35+50+60
20+20+20+20
20+20+20+25
20+20+20+35
20+20+20+50
20+20+20+60
20+20+20+71
20+20+25+25
20+20+25+35
20+20+25+50
Capacity tables
Capacity of each indoor unit (kW)
A room
2.44
3.05
4.27
6.09
7.31
8.65
2.44
2.44
2.44
2.44
2.32
2.11
3.04
3.05
2.98
2.82
2.50
4.26
3.95
3.54
3.17
4.80
4.36
3.97
4.80
4.40
4.80
2.43
2.44
2.38
2.13
1.92
1.73
2.43
2.31
2.02
1.82
1.65
2.14
1.83
1.67
1.52
1.60
1.48
1.37
1.38
2.97
2.82
2.40
2.18
1.98
2.52
2.19
2.00
1.84
1.92
1.77
1.66
3.20
2.80
2.58
2.38
2.48
2.32
2.32
2.26
2.02
1.75
1.60
1.47
2.13
1.92
1.67
B room
2.44
3.05
4.26
6.09
6.95
7.49
3.04
4.26
5.95
6.78
7.10
4.26
5.65
6.06
6.43
4.80
5.24
5.63
4.80
5.20
4.80
2.43
2.44
2.38
2.13
1.92
1.73
3.05
2.90
2.53
2.29
2.07
3.73
3.20
2.92
2.67
4.00
3.69
3.40
4.11
2.97
2.82
2.40
2.18
1.98
3.54
3.05
2.80
2.56
3.84
3.56
3.97
3.20
2.80
2.58
2.38
3.56
3.31
2.32
2.26
2.02
1.75
1.60
1.47
2.13
1.92
1.67
C room
2.43
3.04
4.17
5.34
5.76
6.14
3.05
4.06
5.05
5.49
5.88
3.73
4.57
5.01
5.41
4.00
4.43
4.83
4.11
2.97
3.96
4.80
5.24
5.64
3.54
4.36
4.80
5.20
3.84
4.27
3.97
3.20
4.00
4.44
4.84
3.56
3.97
2.32
2.26
2.02
1.75
1.60
1.47
2.67
2.40
2.09
D room
2.32
2.82
3.54
4.35
4.80
5.19
2.67
3.36
4.17
Total capacity (kW)
Rated (Min._ Max.)
Total power consumption (W)
Rated (Min._ Max.)
Total current (A)
Rated (Min._ Max.)
2.44 (1.31– 4.10)
3.05 (1.36– 4.55)
4.27 (1.48– 4.94)
6.09 (1.90– 6.92)
7.31 (2.19– 7.92)
8.65 (2.50– 8.70)
4.88 (1.62– 6.55)
5.49 (1.76– 6.85)
6.70 (2.05– 7.35)
8.53 (2.47– 8.53)
9.27 (2.74– 9.35)
9.60 (3.04–10.02)
6.08 (1.90– 6.92)
7.31 (2.19– 8.24)
8.93 (2.61– 9.14)
9.60 (2.88– 9.77)
9.60 (3.17–10.02)
8.52 (2.47– 8.87)
9.60 (2.88– 9.74)
9.60 (3.15–10.00)
9.60 (3.45–10.03)
9.60 (3.28–10.27)
9.60 (3.55–10.31)
9.60 (3.85–10.34)
9.60 (3.82–10.35)
9.60 (4.12–10.38)
9.60 (4.42–10.41)
7.29 (2.19– 8.05)
7.92 (2.33– 8.64)
8.93 (2.61– 9.37)
9.60 (3.01–10.32)
9.60 (3.28–10.35)
9.60 (3.58–10.39)
8.53 (2.47– 8.64)
9.27 (2.74– 9.37)
9.60 (3.15–10.32)
9.60 (3.42–10.35)
9.60 (3.72–10.39)
9.60 (3.01–10.01)
9.60 (3.42–10.32)
9.60 (3.69–10.36)
9.60 (3.99–10.39)
9.60 (3.82–10.64)
9.60 (4.09–10.67)
9.60 (4.39–10.71)
9.60 (4.36–10.71)
8.91 (2.61– 9.55)
9.60 (2.88– 9.78)
9.60 (3.28–10.32)
9.60 (3.55–10.35)
9.60 (3.85–10.39)
9.60 (3.15–10.01)
9.60 (3.55–10.32)
9.60 (3.82–10.36)
9.60 (4.12–10.39)
9.60 (3.96–10.64)
9.60 (4.23–10.67)
9.60 (4.50–10.71)
9.60 (3.42–10.02)
9.60 (3.82–10.33)
9.60 (4.09–10.37)
9.60 (4.39–10.40)
9.60 (4.23–10.64)
9.60 (4.50–10.68)
9.28 (2.74– 9.45)
9.60 (2.88– 9.60)
9.60 (3.15–10.37)
9.60 (3.55–10.68)
9.60 (3.82–10.72)
9.60 (4.12–10.75)
9.60 (3.01–10.36)
9.60 (3.28–10.37)
9.60 (3.69–10.68)
710 (330–1,290)
930 (350–1,390)
1,510 (360–1,790)
1,830 (440–2,230)
2,320 (580–2,630)
2,940 (620–2,970)
1,240 (360–1,850)
1,430 (400–1,930)
1,970 (460–2,260)
2,400 (560–2,400)
2,590 (600–2,640)
2,630 (640–2,840)
1,790 (440–2,170)
2,260 (580–2,670)
2,550 (580–2,660)
2,810 (620–2,940)
2,660 (670–2,880)
2,870 (630–3,110)
2,810 (630–2,870)
2,640 (650–2,850)
2,580 (720–2,780)
2,440 (630–2,760)
2,430 (670–2,740)
2,420 (710–2,730)
2,460 (710–2,780)
2,450 (760–2,770)
2,390 (830–2,700)
1,870 (510–2,170)
2,080 (530–2,360)
2,430 (580–2,640)
2,420 (580–2,740)
2,410 (610–2,720)
2,400 (660–2,710)
2,290 (560–2,340)
2,560 (600–2,610)
2,420 (600–2,740)
2,410 (640–2,720)
2,400 (680–2,710)
2,580 (620–2,790)
2,420 (640–2,740)
2,410 (680–2,720)
2,400 (730–2,710)
2,260 (640–2,670)
2,250 (700–2,660)
2,240 (740–2,640)
2,230 (740–2,640)
2,480 (580–2,740)
2,690 (620–2,790)
2,420 (620–2,740)
2,410 (660–2,720)
2,400 (700–2,710)
2,580 (640–2,790)
2,420 (670–2,740)
2,410 (710–2,720)
2,400 (750–2,710)
2,260 (680–2,670)
2,250 (730–2,660)
2,230 (770–2,640)
2,580 (690–2,790)
2,420 (710–2,730)
2,400 (760–2,720)
2,390 (800–2,710)
2,260 (730–2,670)
2,250 (780–2,650)
2,410 (510–2,510)
2,510 (550–2,510)
2,410 (590–2,720)
2,250 (580–2,650)
2,230 (620–2,640)
2,220 (690–2,630)
2,410 (570–2,720)
2,410 (610–2,720)
2,250 (610–2,650)
3.0 (1.4– 5.5)
4.0 (1.5– 5.9)
6.4 (1.5– 7.6)
7.8 (1.9– 9.5)
9.9 (2.5–11.2)
12.5 (2.6–12.6)
5.3 (1.5– 7.9)
6.1 (1.7– 8.2)
8.4 (2.0– 9.6)
10.2 (2.4–10.2)
11.0 (2.6–11.2)
11.2 (2.7–12.1)
7.6 (1.9– 9.2)
9.6 (2.5–11.4)
10.8 (2.5–11.3)
11.9 (2.6–12.5)
11.3 (2.8–12.2)
12.2 (2.7–13.2)
11.9 (2.7–12.2)
11.2 (2.8–12.1)
11.0 (3.1–11.8)
10.4 (2.7–11.7)
10.3 (2.8–11.6)
10.3 (3.0–11.6)
10.5 (3.0–11.8)
10.4 (3.2–11.8)
10.2 (3.5–11.5)
8.0 (2.2– 9.2)
8.8 (2.3–10.0)
10.3 (2.5–11.2)
10.3 (2.5–11.6)
10.2 (2.6–11.6)
10.2 (2.8–11.5)
9.7 (2.4– 9.9)
10.9 (2.6–11.1)
10.3 (2.6–11.6)
10.2 (2.7–11.6)
10.2 (2.9–11.5)
11.0 (2.6–11.9)
10.3 (2.7–11.6)
10.2 (2.9–11.6)
10.2 (3.1–11.5)
9.6 (2.7–11.4)
9.6 (3.0–11.3)
9.5 (3.1–11.2)
9.5 (3.1–11.2)
10.5 (2.5–11.6)
11.4 (2.6–11.9)
10.3 (2.6–11.6)
10.2 (2.8–11.6)
10.2 (3.0–11.5)
11.0 (2.7–11.9)
10.3 (2.8–11.6)
10.2 (3.0–11.6)
10.2 (3.2–11.5)
9.6 (2.9–11.4)
9.6 (3.1–11.3)
9.5 (3.3–11.2)
11.0 (2.9–11.9)
10.3 (3.0–11.6)
10.2 (3.2–11.6)
10.2 (3.4–11.5)
9.6 (3.1–11.4)
9.6 (3.3–11.3)
10.2 (2.2–10.7)
10.7 (2.3–10.7)
10.2 (2.5–11.6)
9.6 (2.5–11.3)
9.5 (2.6–11.2)
9.4 (2.9–11.2)
10.2 (2.4–11.6)
10.2 (2.6–11.6)
9.6 (2.6–11.3)
Outdoor
unit
4MXS80EVMA
Heating
capacity
Combinations
of indoor units
20+20+25+60
20+20+25+71
20+20+35+35
20+20+35+50
20+20+35+60
20+20+50+50
20+25+25+25
20+25+25+35
20+25+25+50
20+25+25+60
20+25+25+71
20+25+35+35
20+25+35+50
20+25+35+60
20+25+50+50
20+35+35+35
20+35+35+50
25+25+25+25
25+25+25+35
25+25+25+50
25+25+25+60
25+25+35+35
25+25+35+50
25+25+35+60
25+35+35+35
25+35+35+50
35+35+35+35
Capacity of each indoor unit (kW)
A room
1.54
1.41
1.75
1.54
1.42
1.37
2.01
1.82
1.60
1.47
1.37
1.67
1.48
1.38
1.32
1.53
1.37
2.40
2.18
1.92
1.78
2.00
1.78
1.66
1.86
1.65
2.40
B room
1.54
1.41
1.75
1.54
1.42
1.37
2.53
2.29
2.00
1.85
1.70
2.09
1.85
1.71
1.66
2.69
2.40
2.40
2.18
1.92
1.78
2.00
1.78
1.66
2.58
2.32
2.40
C room
1.92
1.76
3.05
2.69
2.49
3.43
2.53
2.29
2.00
1.85
1.70
2.92
2.58
2.40
3.31
2.69
2.40
2.40
2.18
1.92
1.78
2.80
2.49
2.32
2.58
2.32
2.40
D room
4.60
5.02
3.05
3.83
4.27
3.43
2.53
3.20
4.00
4.43
4.83
2.92
3.69
4.11
3.31
2.69
3.43
2.40
3.06
3.84
4.26
2.80
3.55
3.96
2.58
3.31
2.40
Total capacity (kW)
Rated (Min._ Max.)
Total power consumption (W)
Rated (Min._ Max.)
Total current (A)
Rated (Min._ Max.)
9.60 (3.96–10.72)
9.60 (4.26–10.75)
9.60 (3.55–10.38)
9.60 (3.96–10.69)
9.60 (4.23–10.73)
9.60 (4.36–11.00)
9.60 (3.15–10.36)
9.60 (3.42–10.37)
9.60 (3.82–10.68)
9.60 (4.09–10.72)
9.60 (4.39–10.75)
9.60 (3.69–10.38)
9.60 (4.09–10.69)
9.60 (4.36–10.73)
9.60 (4.50–11.00)
9.60 (3.96–10.38)
9.60 (4.36–10.70)
9.60 (3.28–10.36)
9.60 (3.55–10.37)
9.60 (3.96–10.68)
9.60 (4.23–10.72)
9.60 (3.82–10.38)
9.60 (4.23–10.69)
9.60 (4.50–10.73)
9.60 (4.09–10.38)
9.60 (4.50–10.70)
9.60 (4.36–10.39)
2,230 (640–2,640)
2,220 (710–2,630)
2,400 (660–2,720)
2,240 (670–2,650)
2,230 (720–2,640)
2,090 (660–2,590)
2,410 (590–2,720)
2,410 (640–2,720)
2,250 (630–2,650)
2,230 (690–2,640)
2,220 (740–2,630)
2,400 (680–2,720)
2,240 (700–2,650)
2,230 (740–2,640)
2,090 (710–2,590)
2,400 (730–2,710)
2,240 (750–2,650)
2,410 (610–2,720)
2,410 (660–2,720)
2,250 (680–2,650)
2,230 (720–2,640)
2,400 (710–2,720)
2,240 (720–2,650)
2,230 (770–2,640)
2,400 (760–2,710)
2,240 (770–2,650)
2,400 (810–2,710)
9.5 (2.7–11.2)
9.4 (3.0–11.2)
10.2 (2.8–11.6)
9.5 (2.8–11.3)
9.5 (3.1–11.2)
8.9 (2.8–11.0)
10.2 (2.5–11.6)
10.2 (2.7–11.6)
9.6 (2.7–11.3)
9.5 (2.9–11.2)
9.4 (3.1–11.2)
10.2 (2.9–11.6)
9.5 (3.0–11.3)
9.5 (3.1–11.2)
8.9 (3.0–11.0)
10.2 (3.1–11.5)
9.5 (3.2–11.3)
10.2 (2.6–11.6)
10.2 (2.8–11.6)
9.6 (2.9–11.3)
9.5 (3.1–11.2)
10.2 (3.0–11.6)
9.5 (3.1–11.3)
9.5 (3.3–11.2)
10.2 (3.2–11.5)
9.5 (3.3–11.3)
10.2 (3.4–11.5)
Notes: 1. Cooling operation data is based on the following conditions: indoor temp. 27 ˚CDB, 19 ˚CWB; outdoor temp. 35 ˚CDB.
2. Heating operation data is based on the following conditions: indoor temp. 20 ˚CDB; outdoor temp. 7 ˚CDB, 6 ˚CWB.
3. Total capacity of connected indoor units is: up to 9.0 kW to the 3MXS52E; up to 11.0 kW to the 3MXS68E; up to 14.5 kW to the 4MXS80E.
4. A single indoor unit cannot be connected.
34