Endeavor® 6kVA Rackmount/Tower UPS Series
Double Conversion On-line True Sine Wave
Uninterruptible Power Supply
ED6200RM - 6000VA/4200Watts UPS
ED6000RMXFMR - Transformer Module
EDBP6000RM - Battery Pack Module
Minuteman® 6kVA On-Line Rackmount/Tower UPS.
• Simple
parallel installations (no extra PCB
required)
• Full digital signal processor
• Easy-to-set user personalization
• Intelligent self diagnosis
• Smart fan control
• Emergency Power Off (EPO) function
• True double conversion on-line technology
• High input Power Factor and low voltage THD
• Energy efficient UPS
• LCD/LED panel
• 2X customer options slots
• Smart ECO
• i-Batt (automatically manages end of discharge
6kVA on-line UPS Features
• True on-line architecture supplies critical device
with transient-free pure sine wave AC power
• LCD/LED front panel displays status of UPS
• Switches to bypass automatically in case
overloading at 150%
• Maintenance free sealed-type battery minimizes
after-sales service
• Intelligent, temperature-controlled
• Can be configured as tower or rackmount
Options
• Maintenance bypass
• Galvanic isolated transformer
voltage according to load capacity)
• Cold start function
• Communication capability
• Remotely test the major operating functions
•
•
of UPS
Communicate via SNMP/Web card
Access UPS via the Internet
Applications
•
•
•
•
•
•
of
VoIP
Data centers
Server racks
Large network switches
Total rack tower support
Large PBX systems
Para Systems, Inc. • 800.238.7272• 1455 LeMay Drive • Carrollton, Texas 75007 USA
www.minutemanups.com•www.sizemyups.com • www.sizemypdu.com • www.comparemyups.com
Parallel for Capacity Configurations
Endeavor 6kVA True On-line
Rackmount/Tower UPS
RS-232
Connector
Emergency
Power Off
Cooling
Fans
UPS
Output
Connector
Utility
Input
Connector
Utility
Input
Breaker
Terminal Resistor
for Parallel
Function &
CAN Bus
Connection
for Parallel System
Maintenance
Bypass
Connection
Option Option
Card
Card
Slot 1 Slot 2
This configuration uses mirrored Endeavor 6kVA
rackmount UPS system to achieve higher than 6kVA loads.
Currently, parallel capacity configurations can be used
to accommodate output loads of 12, 18, and 24kVA for
208V/240V systems.
Uninterruptible
Power
Supply
Transformer
for 120V
System
External
Battery
Connectors
Battery
Module
Additional
Battery
Pack
Connection
Transformer UPS Utility
Output Input
Output
208V 120V
120V
208V
240V
UPS
Input
120V
208V
240V
Maintenance
Bypass
DC
Breaker
Main Control Module - ED6200RM
The Main Control module takes only 2U in rack height
and provides 208/240V input and output. Input is hardwired
to the unit. The main control module has a LCD/LED display.
Each control module must have at least one battery back
(EDBP6000RM). Parallel functions are available for up to 208V
24kVA. N+1 full-redundancy function is available up to 18kVA for
208/240V applications and 6kVA for 120V applications. Optional
receptacle boxes are available for 6kVA units.
Transformer Module - ED6000RMXFMR
The transformer module steps down the 208/240V input to
120/208/240V output, takes 2U in rack height, and requires a
control module (ED6200RM), and Battery Pack (EDBP6000RM) to
work. It has an internal bypass switch for single 6kVA installations
(Not available on parallel installations). It handles 208/240V input
and 120/208/240V output.
Parallel for Capacity Configuration Table
Model
ED12000RM
ED18000RM
ED24000RM
Input
12kVA
208V/240V
18kVA
208V/240V
24kVA
208V/240V
Output Load
12kVA
208V/240V
18kVA
208V/240V
24kVA
208V/240V
Watts
8400
12600
16800
Rack height
10 U
15 U
20 U
ED6200RM
2
3
4
EDBP6000RM
Battery Pack
2
3
4
ED6-PARALLEL
Parallel kit
1
1
1
External
Maintenance
Bypass Switch
1
ED6-MTBS2
1
ED6-MTBS4
1
ED6-MTBS4
Redundancy (N+1) Configurations
This configuration is used to provide redundancy
backup. When one UPS is taken offline, this configuration
allows the load to be redistributed to the remaining UPS
units.
Battery Pack Module - EDBP6000RM
Each battery pack module (EDBP6000RM) occupies 3U
in rack height and requires a control module (ED6200RM) to
operate. Multiple battery packs can be daisy chained. Only one
receptacle box can be attached to a battery pack module.
Battery packs are charged through the main UPS.
Parallel Configurations
In addition to a stand-alone configuration, the Endeavor
6kVA rackmount UPS can be configured as:
•
•
Redundancy (N+1) Configuration Table
Model
TBA
ED12000RM
ED18000RM
ED24000RM
6kVA
208V/240V
6kVA
208V/240V
12kVA
208V/240V
18kVA
208V/240V
Output Load
6kVA
120V
6kVA
208V/240V
12kVA
208V/240V
18kVA
208V/240
Watts
4200
4200
8400
12600
Rack height
14 U
10 U
15 U
20 U
Input
Parallel for capacity (12, 18 and 24kVA output load)
Redundancy (N+1) (6, 12, and 18kVA). This allows all
of the load to be shifted to the other UPS units when
one is taken offline. Configurations using more than two
control modules will require a parallel kit and an external
maintenance bypass switch.
NOTE: 120V output from the Endeavor 6kVA rackmount UPS is
available only in a 6kVA stand-alone configuration or a Parallel
for Redundancy (N+1) 6kVA 208V/240V input and 6kVA 120V
output made up of two ED6200RM control units, two EDBP6000RM
battery packs and two ED6000RMXFMR transformers.
ED6200RM
2
2
3
4
EDBP6000RM
Battery Pack
2
2
3
4
ED6000RMXFMR
2
n/a
n/a
n/a
ED6-PARALLEL
Parallel kit
1
1
1
1
External
Maintenance
Bypass Switch
N/A
1
ED6-MTBS2
1
ED6-MTBS4
1
ED6-MTBS4
Optional Receptacle Boxes
Two receptacle boxes are available. One for
208V/240V output only (ED6-208RB) and one for both
120V and 208V/240V output (ED6-120RB).
208V-Only Receptacle Box- ED6-208RB
Receptacles: (1) L6-30R, (1) L6-20R and (4) 6-15/20R. Only
one receptacle box can be connected to a battery
pack.
Endeavor 6kVA UPS LED/LCD
Front Panel Display/Control
The Endeavor 6kVA UPS multi-functional LCD/LED panel will
display various states of the UPS. The LED display will show the
UPS working status, Utility Status and UPS Abnormal status. The
LCD display will show the Input/Output voltage, frequency, load
status, internal temperature, and faults.
Configuring the UPS parameters are done through the LCD.
Utility
Input
Normal
Bypass
Input
Normal
UPS in
Redundancy
Mode
UPS in
ECO
Mode
UPS Fault
or
Abnormal
Warning
120V/208V Receptacle Box - ED6-120RB
Receptacles: (1) L6-30R, (1) L5-30R, (1) L5-20R and (2)
5-15/20R. Only one receptacle box can be connected to
a battery pack.
LEDs
V
Enter or
Reconfirm
Communication and Software
The Endeavor 6kVA UPS currently uses the NetAgent
SNMP card and includes software for monitoring the UPS.
A new version of the ED6200RM with SentryPlus/SNMP-NET
communications capability will be available in 2008.
Previous Page
or Setting
Change
Both versions are compatible with Minuteman’s
new SentryGold Enterprise Software which permits the
monitoring and control of Minuteman UPS and Power
Distribution Units.
Batteries
The Endeavor 6kVA UPS uses a battery pack
(EDBP6000RM) that contains sealed, non-spillable,
maintenance free, value regulated, lead acid batteries.
The UPS module does not have internal batteries. Typical
recharge time for the battery pack is 8 hours from total
discharge.
UPS On Switch UPS
&
Off
Alarm Silence Switch
Special
Log In/
Log Out
Next
Page
Maintenance Bypass Switch
The battery pack contains (20) 12V 7.2Ah batteries.
Runtime at full load is 9 minutes. At half load the
runtime is 23 minutes
What the future holds . . .
Parallel
Configurations:
All
current
6kVA products are compliant with parallel
configurations when these options are
available. In the relatively near future you will
be able to configure your Minuteman Endeavor
6kVA into a parallel configuration increasing
system capacity up to 24kVA.
•
•
Input and output will be hardwired
A parallel kit will be required. It will contain all
the required RJ-45 cabling and an instruction
•
manual
It is required that a maintenance bypass switch
be installed
Maintenance Bypass Switch with covers off
The maintenance bypass switch removes the requirement to
power down the UPS to perform routine maintenance, replace
batteries or to change battery configuration, The maintenance
bypass switch is usually mounted adjacent to the UPS, enabling
the UPS to be isolated from the load without interrupting power
to essential applications.
Options
• Maintenance bypass switch
• Galvanic isolated transformer for 120V applications.
• Parallel kit
Model
Endeavor® 6kVA Series On-line Rackmount UPS
ED6200RM
DDouble Conversion On-Line, True Sine Wave
Topology
Maximum power capacity
Voltage window
6000VA/4200Watts
INPUT
160~280VAC*
Frequency
50/60 Hz ± 5Hz autosensing
Number of phases • Surge energy rating
Single (1Ø 2W +G) • 1050J
Power factor correction
≥98% at 100% Linear Load
Voltage window
OUTPUT
200/208/240VAC selectable 120V with transformer
Voltage adjustment / Voltage regulation
0%; ±1%; ±2%; ±3% /±2%
Capacity
6000VA/4200W
Rated power factor
0.7 Lagging
Wave form
Sine Wave
Frequency Regulation
±0.2%(Free Running) unless synchronized to utility
Transfer time
0ms
Efficiency
> 87% line mode
Autonomy full/half
9 min/23 min
Voltage THD
<3% at 100% Linear Load
BATTERY
Type
Sealed non-spillable lead acid maintenance free 12V/7.2Ah
Quantity / Voltage / Recharge Time
20pcs / 240VDC / 8 hours to 90%
DISPLAY
Line mode, backup mode, ECO mode, bypass, battery low, battery bad/disconnect,
overload, and transferring with interruption & UPS fault.
Input voltage, input frequency, output voltage, output frequency, load percentage,
battery voltage & internal temperature.
Upon power-on, front panel setting & software control
Status On LED + LCD
Readings on LCD
Self-diagnostics
ALARMS
Audible and Visual
Line failure, battery low, transfer to bypass, system fault conditions
PHYSICAL
Dimensions- WxDxH- in (mm)
Input/output connection / External battery
connection
Net weight(kg)
17.3x3.4x26.7in (440x88x680mm) - (UPS Module)
Hardwired / Plug and Play
53.0 lb/ 24kg(UPS Module)
Battery pack net weight
120.0 lb (54.2 kg)
Battery Bank Dimensions
Convertible(Rack/Tower) / 17.3x5.2x26.7in (440x132x680mm) (3U)
Isolation transformer dimensions/ Net weight
17.3x3.4x 26.7in (440x88x680mm) - (2U) / 93 lb (42 kg)
ENVIRONMENT
Operating temperature
Altitude / Humidity
Noise
Interface type
Communication slots
32°F to 104°F (0°C to 40°C)
0~2000m up to 104°F (40°C), 3000m up to 95°F (35°C)
/ 90% RH Maximum, Non-Condensing
<50dB (at 1 meter)
COMPUTER INTERFACE
Standard RS-232 Interface
2nd RS-232 **, USB *** Relay Contact, SNMP/WEB Card, etc.
SAFETY CONFORMANCE
Safety and approvals
EMC
UL 1778, cUL (CSA 2.2 no. 107.1), CE (EN62040-1-1)
CE (EN62040-2, EN61000-3-2, EN61000-3-3), FCC Class A
Para Systems, Inc./Minuteman UPS
1455 LeMay Drive, Carrollton, TX 75007 U.S.A.
Phone 800.238.7272 +1 972.446.7363 Fax +1 972.446.9011
© Copyright 2008, Para Systems, Inc. Product specifications are subject to change
without notice. Minuteman is a registered trademark of Para Systems, Inc.
Power Technologies
From Para Systems, Inc.
www.minutemanups.com•www.sizemyups.com • www.sizemypdu.com • www.comparemyups.com
PN-34000314 - 4-2008