Catalogue 2009
Residential
Light commercial
Commercial
Range 2009
Residential, Light commercial
and Commercial
Advanced air conditioning technology
Research and technological innovation have been the goals of Mitsubishi Heavy Industries
for over a century and these have been translated into the excellent results obtained in the
air conditioning market. The perfect harmony between energy, technology and innovation
is manifested in the production of air conditioners designed to meet the engineering
requirements of the residential, commercial and industrial sectors. State-of-the-art solutions
applied to top quality products guarantee comfort, energy efficiency, and quality of life.
For a better tomorrow.
Profile
2-3
Range 2009
4-5
Residential and
Light Commercial
Range 2009
6-39
Commercial
Range 2009
40-56
Individual controls
57-60
Superlink II
61-64
The global activity of
Mitsubishi Heavy Industries, Ltd.
The origin of the brand dates back to the last
decade of the nineteenth century in Nagasaki,
where the first big shipyard was established
to produce ships for the Japanese navy.
Shipbuilding is still one of the most important
sectors for Mitsubishi Heavy Industries.
Subsequently Mitsubishi implemented a
progressive diversification and extension
of its activity in heavy industry, as well as in
the airplane, rail and car sectors, becoming
the biggest private company in Japan in
the 1930’s. Mitsubishi Heavy Industries
still operates in the car sector through its
subsidiary company Mitsubishi Motors.
In the post-war period there was a organised
process of corporate downsizing by American
industry for the protection of the same.
engines for boats and fans) and keeping the
three-pointed diamond as its logo, just like
the parent company.
The current need for alternative energy
resources in fact, sees Mitsubishi Heavy
Industries constantly committed to searching
for state-of-the-art solutions that can preserve
the delicate balance of the ecosystem both
today and in the future.
The competitor Mitsubishi Electric was set up
in 1921 as one of these spin offs, producing
a limited number of products (electrical
Today Mitsubishi Heavy Industries is a
market leader in various sectors of traditional
industry, but it is also one of the major players
in innovative technological sectors such as
aviation, aerospace, robotics, and renewable
energy.
2
Industry
Resources/energy
Transportation
Comfort
• Chemical Plants
• Wind Tunnels/Test Rigs
• Casting and Foundry
Equipment
• Strip Mills
• Cement Plant
• Industrial Robots
• Injection Moulding Machines
• Pulp & Paper Machinery
• Production of Corrugated
Packaging
• Box Making Machines
• Machine Tools
•
•
•
•
•
•
•
•
•
•
•
•
Crude Oil Storage Barges
LNG Tanks
Boilers & Turbines
Oil Production Plants
Thermal Power Plants
Combined Cycle Plants
Fuel Cells
Water Turbines
Wind Turbines
Geothermal Power Plants
PWR Nuclear Power Plants
Uranium Enrichment
Equipment
• Co-Generation Systems
• Unloader & Container Cranes
• Mechanical Parking Facilities
• Integrated Automated Storage
Systems
• Rubber & Tyre Manufacturing
Plant
• Skyrails
• Monorail Cars
• New Transportation Systems
• Passenger Boarding Bridges
• Toll Collection Machine
Systems
• Forklift Trucks
• Helicopters
• Aircraft
• Railway Maintenance
Equipment
• LNG Carriers
• Container Ships
• Air conditioners for residential
and commercial applications
• Automotive air conditioners
• Refrigeration units
• Dry cleaning machines
• Equipment for the food
industry
• Cruise ships
• Multipurpose domes
Local development
Environment
Research and development
Defence
•
•
•
•
•
•
•
•
•
•
•
•
• Oceanographic research ships
• Deepsea research vehicles
• Communication satellites and
rockets
• Space transportation
• Rockets and engines
•
•
•
•
•
Spillway Radial Gates
Steel Bridges
Penstocks
Desalination Plants
Logistics and Transportation
Turbines
Cabling Systems
Ultra-High Steel Stacks
Refuse Incineration Plants
Night Soil Treatment Plants
Fluidized Incinerators
CFC Collecting Equipment
Submarines
Naval vessels
Jet fighters
Helicopters
Missiles
The advent of the third millennium saw Mitsubishi Heavy Industries venture into sectors
of the greatest importance for the future of the planet, amongst which are research into
alternative energy sources and space exploration, with a constant commitment to guarantee
development whilst keeping man and technology in perfect harmony.
3
Range 2009
Residential, Light commercial
Modern, high performing and compact: Mitsubishi Heavy
Industries air-conditioners can enhance all areas requiring
conditioning systems and ensure comfort, energy saving
and reliability, fully respecting the environment.
Energy Efficiency
Class A/A
Quality of air and well-being
Comfort
Mitsubishy Heavy Industries airconditioners are designed and
developed to ensure quality of air
and well-being. The anti-bacterial
treatment of the fan, together with
the united action of special filters help
in neutralizing bacteria, viruses and
allergens and keeping air in the room
clean and safe.
Sleep mode ensures comfort and well-being during the night: the room
temperature is automatically controlled and decreased, so to balance the natural
drop of the body temperature while sleeping. Furthermore, Mitsubishi Heavy
Industries air-conditioners show automatic operation mode – cooling/heating/
dry/air flow/clean air – and low noise levels that help in having the best standard
of comfort at any time.
High efficiency
DC PAM Inverter technology ensures the highest energy efficiency and the lowest
power consumption. Compared to a constant speed system, the compressor
output can ensure quick heating after the start up and attain a set temperature
more quickly. Then the air-conditioner can slow down its compressor speed to
save energy , keeping comfortable conditions.
4
and Commercial
Energy saving
Most of Mitsubishi Heavy Industries airconditioners reach the highest energy efficiency
class A/A – in cooling and heating – thus ensuring
the highest energy saving level and the best energy
efficiency.
The research laboratories of Mitsubishi Heavy
Industries have always been committed to the
study and applications of new technologies, in order
to develop high quality products in the full respect
for the environment.
Residentian and Light commercial
Thanks to innovation and research in technology Mitsubishi Heavy
Industries presents the new Residential series, improved in design,
energy efficiency and application potentials. The new indoor units of
DC Inverter Ultra series allow high energy performance and flexibility
for both small and medium sized residential applications.
Latest generation air-conditioners, providing energy saving, comfort
and high performance.
Commercial
Light-commercial series is
designed to meet the needs
of medium sized commercial
applications, guaranteeing a
sophisticated and reliable airconditioning systems every time
of the year.
5
Residential and
Light commercial Range 2009
Mitsubishi Heavy Industries heat pump air-conditioners
are designed paying attention to every single detail.
Innovative in technology, designed to give the maximum
energy saving rate, both in small and medium applications,
these products are the customized answer to all residential
comfort requirements.
Care for the Environment, Comfort and Energy Efficiency
6
New DC Inverter Ultra Series
SRK ZIX-S
Wall-mounted
A/A Class
COP 5,56
(mod. SRK 20 ZIX-S)
Wall-mounted and floor
standing units of the new
DC Inverter Ultra series
show a sophisticated
and modern design,
that enhances all
rooms requiring an airconditioning system.
Energy efficiency class
A/A – in cooling and
heating –ensures
the lowest power
consumption and the
best energy efficiency.
SRF ZIX-S
Floor standing
A/A Class
COP 4,70
(mod. SRF 25 ZIX-S)
7
Residential and
Light commercial Range 2009
High performance,
maximum reliability
and long life,
silent operation
and an elegant
and sophisticated
design: these are
the main features
of a high-grade
air-conditioning
system.
Energy Efficiency
Uniform air diffusion
Well-being and Comfort
The research laboratories of Mitsubishi
Heavy Industries have always been
committed to the study and application
of new technologies, whose results are
high quality products guaranteeing
high efficiency in the full respect for the
environment.
Silicon-coated PCB
New propeller fan
Scroll compressor
Leaf shape grill
ZAM steel sheet
High Efficiency
Inverter Control (Vector)
Silicon-coated PCB
The PAM DC Inverter system guarantees high
energy efficiency thanks to its new motor
with permanent magnets, which increases
low pressure electrical efficiency thanks to the
reduced interior attrition. The machine limits
energy absorption when it is not necessary (e.g.
whilst maintaining temperature) or increases its
absorption when the desired climatic conditions
need to be reached rapidly (e.g. during start up).
The new inverter control applies the latest
developments in vector control to attain high
efficiency.
• Smooth operation from low to high speed.
• Smooth Sine Wave voltage is achieved.
• Improved energy efficiency even at low rotational
speeds.
The printed wiring board of
the outdoor unit is coated by
silicon, so that it can have a
better tolerance for humidity
and last longer.
8
Energy Efficiency
HIGH COP: efficiency and energy saving
All models of the Hyper
and Ultra lines feature an
extremely high energy
efficiency rate, and all are
class A for COP and EER
values.
Shape grill
New propeller fan
Scroll compressor
The new radial shape grill has been developed
in order to realize a natural air flow sent by
the propeller fan along with it. The airflow is
very smooth with the least air resistance and
the decrease of the motor load leads to an
improvement in the energy efficiency.
Matching the new design of the
propeller fan with the features of the fan
motor led to keep the same capacity
as that of previous models with lower
electrical consumption. The synergy
effect with the leaf shape grill provides
an improvement of energy efficiency
by 5% compared to previous models
(SRC 50~60 ZIX-S).
Scroll compressor helps in
improving energy efficiency
and in reducing vibrations and
sound levels. Furthermore, the
use of a neodymium magnet
applied in the motor produces
huge energy, thus reducing the
energy loss occurred during
the compression phase
(SRC 50~60 ZIX-S).
Steel sheet
Steel sheet is applied at the base of the outdoor
units and can ensure a great steadiness to the
anchor bolt. It is coated with ZAM, a coined
name applied to hot-dipped zinc-aluminummagnesium-alloy, having higher corrosion
resistance properties compared to conventional
materials. ZAM is a registered trademark of Nissin
Steel Co., Ltd.
9
Residential and
Light commercial Range 2009
Ideal temperatures every day, accurate and
modern design, quality of air, silent operation
and energy saving are the elements Mitsubishi
Heavy Industries offers to achieve the desired
well-being.
Horizontal positions
Three-dimensional ventilation
The innovative 3D Ventilation system of Mitsubishi Heavy Industries
characterizes all wall-mounted models (exept for ZDX-S and HG-S).
This system can be selected both in manual and automatic mode,
enabling a better distribution and de-stratification of treated
air, in the air-conditioned area. In manual mode, thanks to the 2
dedicated keys on the remote control, 7 different settings can be
selected, for horizontal and vertical flow, besides SWING mode
(continuous motion of the louvers).
Three-dimensional ventilation: AUTO
mode
The 3D Auto system is a programmable mode, thanks to one
only key on the remote control: 3 motors – one for horizontal
movement and 2 for vertical movement – allow you to have 3
independent air flow controls.
Air flow is uniform, silent and can reach long distances from the
indoor unit. Air flow, in the air-conditioned room, is uniformly
sent, on the basis of the programmed 3D ventilation automatic
mode (SRK ZIX-S; SRK/SKM ZG-S).
10
Wide
Swing
Spot
Swing
Vertical movement
Uniform air diffusion
Jet Air Scroll
CFD (Computational fluids dynamics)
technology, used in the blade shape design of
jet engines, has been applied to air-conditioning,
to develop air channels with an optimal air
circulation system.
The air flow obtained thanks to this system
enables the diffusion of a large volume of air,
with extremely low energy consumption, as
there is a marked reduction in the stagnation of
collected air flow, thus reducing energy waste
appreciably. The air flow is then uniform, silent,
and can reach long distances, i.e., perfect for
large air-conditioned areas.
Slow
Fast
Selection and setting by IR controller
New size and shape of the louver
By using the IR controller it is possible to select
(air flow, up/down) and set (3D auto) air scroll and
direction swing (SRK 71 ZE and HE just have the manual setting).
The redesigned size and shape of the new louver improves 3D
air flow. The thinner profile and the addition of 80% surface area
helps in increasing the air flow volume and in improving the
lateral swinging (SRK ZIX-S).
Long reach flow
The increased surface of the louvers helps in the distribution of
the air flow, which is uniform, quiet and reaches long distance
points from the blower.
SRK 50~60 ZIX-S
(cooling)
15 m
previous model
new model
SRK 71 ZE-S1
(cooling)
17 m
11
Residential and
Light commercial Range 2009
All the products of the range mount an air-filtration
and air-purifier system, in a position to clean the
air of the room, to prevent allergies and upper
respiratory diseases, contrasting the formation of
bacteria and mould.
Photocatalytic filter
The photocatalytic filter keeps
air clean and pleasant, thanks to
its double action: filtering and
deodorizing. The filter is selfregenerating, simply washing it in
water and then letting it dry in the
sunlight.
Natural enzyme filter
From the Mitsubishi Heavy Industries laboratories, another revolutionary product for
air purification: the natural sterilizing enzyme filter, which, unlike traditional filters,
does not possess any chemical compounds or heavy metals.The enzymes’ action is
localized, without any risk of materials being irradiated or dispersed in the environment.
The enzymes attack the micro-organisms that are in the air, and that can cause many
pathologies transmitted through the air, by trapping them into the filter and destroying
them.
12
Anti-allergenic filter
The new anti-allergenic filter, mounted on every
model of the DC Inverter Monosplit Smart line,
is a unique brand-new feature, resulting from
Mitsubishi Heavy Industries research, and which is
in a position to neutralize the action of pollen, mite,
bacteria and many other allergens which can be
found in the air. Neutralization capacity is given by
the combined action of urea and natural enzymes:
treated air is free from impurities, and your health
is protected. The self-cleaning function of this filter
can be selected by pressing the “ALLERGEN CLEAR”
key.
Well-being and Comfort
Self Clean function: automatic sanitization
against moulds
Self clean
Operation
Thanks to the self- regenerating function, all
components of indoor units are submitted to an
automatic sanitization process, stopping mould
proliferation and getting rid of the rank smell
they produce.
This function can be selected by pressing the
“clean” switch on the remote control, and starts
at the end of the machine’s operating cycle. The
operation can last 2 hours max., but it can be
nevertheless interrupted, by pressing the “on/off”
key on the remote control.
Stop
2h
Normal operation
Automatic switch-off
Allergen Clear System:
sanitization against allergens
Allergen
Clear System
This is another exclusive feature of Mitsubishi Heavy Industries, in
a position to neutralize the effects of the pathogen agents that
lay on the surface of the allergenic filter. The filter can be cleaned
by pressing the “allergen” key, on the remote control.
The operation can last about 1h 30’, and then automatically stops.
The plastic component of the fan’s blades is made of antibacterial material, so to better resist against moulds and
germs proliferation.
SRK
ZIX-S
SRF
ZIX-S
SRK
ZGX-S
SRK
ZE-S1
SRK
ZG-S
SRK
ZDX-S
SRK
HG-S
SRK
HE-S1
SKM
ZG-S
Sanitizations against moulds (Self Clean)
X
—
X
X
X
—
X
X
X
Sanitizations against allergens (Allergen Clear)
X
—
—
X
X
—
—
—
—
Antiallergenic filter
X
—
X
X
X
X
—
—
—
Natural enzyme filter
—
X
—
—
—
—
X
X
X
Photocatalytic filter
X
X
X
X
X
X
X
X
X
3D ventilation
X
—
X
X
X
—
—
X
X
Functions
Air treatment functions
related to each model
of Residential and Light
commercial line are shown
in the chart
Anti-bacterial fan treatment
13
Residential and
Light commercial Range 2009
New DC Inverter Ultra Light commercial Series
Compact, sophisticated and fit to the needs of small/medium
sized residential and light-commercial applications, DC Inverter
Ultra air-conditioners provide:
• high energy performance: energy class A, both in cooling and
heating, for high-mounted, floor standing and cassette units.
• installation versatility: up to 30 m pipe length for 5,0 and 6,0
kW units;
• high comfort: 21 dB(A) (SRK 20 ZIX-S) and 26 dB(A)
(SRF 25 ZIX-S) sound pressure; special filters guaranteeing
clean air.
New
New Monosplit DC Inverter Ultra Light commercial Series
Wall-mounted
Floor
standing
4-ways
Cassette 84x84
Ceiling
4-ways
Cassette 60x60 suspended
Ducted
medium
Outdoor units
2,0 kW
SRK 20 ZIX-S
SRC 20 ZIX-S
2,5 kW
SRK 25 ZIX-S
SRF 25 ZIX-S
SRC 25 ZIX-S
3,5 kW
SRK 35 ZIX-S
SRF 35 ZIX-S
SRC 35 ZIX-S
4,0 kW
5,0 kW
SRK 50 ZIX-S
6,0 kW
SRK 60 ZIX-S
SRF 50 ZIX-S
FDT 40V
FDTC 40V
FDEN 40VA
FDT 50V
FDTC 50V
FDEN 50VA
FDUM 50V
SRC 50 ZIX-S
FDEN 60VA
FDUM 60V
SRC 60 ZIX-S
FDT 60V
SRC 40 ZIX-S
40~60 ZIX-S can be selected for use as indoor units in the combination with V Multi system outdoor units. Refer to the Commercial
section for details.
14
Monosplit
Multisplit
DC Inverter Ultra, Hyper and Flat models show an essential and
modern design. The most models are Energy Class A/A, with
noise levels within 21 dB(A). Outdoor units, whose design is
ultra-compact, have undergone a special anti-rust treatment, thus
preventing any damage caused by weather conditions.
The Multisplit air-conditioning system allows to combine a max
of 4 indoor units of different models and power capacity, to one
only outdoor unit. Indoor units show maximum versatility, both
in residential and light-commercial applications. Outdoor units,
in a range of 5 different power capacities, show extra compact
dimensions, thus simplifying transport and installation operation.
Monosplit
Indoor units
DC Inverter
Hyper
DC Inverter
Flat
SRK-SRC 20 ZGX-S
SRK-SRC 20 ZG-S
DC Inverter
Ultra
DC Inverter
Smart
Constant Speed
2,0 kW
SRK-SRC 20 ZIX-S
2,5 kW
SRK-SRC 25 ZIX-S
SRF-SRC 25 ZIX-S
SRK-SRC 25 ZGX-S
SRK-SRC 25 ZG-S
3,5 kW
SRK-SRC 35 ZIX-S
SRF-SRC 35 ZIX-S
SRK-SRC 35 ZGX-S
SRK-SRC 35 ZG-S
SRK-SRC 40 HG-S
5,0 kW
SRK-SRC 50 ZIX-S
SRF-SRC 50 ZIX-S
SRK-SRC 50 ZGX-S
SRK-SRC 50 ZG-S
SRK-SRC 56 HE-S1
6,0 kW
SRK-SRC 60 ZIX-S
7,1 kW
SRK-SRC 20 HG-S
SRK-SRC 25 ZDX-S
SRK-SRC 28 HG-S
SRK-SRC 71 ZE-S1
Multisplit
Indoor units
Wall-mounted
4-ways Cassette
60x60
2,0 kW
SKM 20 ZG-S
2,2 kW
SKM 22 ZG-S
2,5 kW
SKM 25 ZG-S
2,8 kW
SKM 28 ZG-S
3,5 kW
SKM 35 ZG-S
STM 35 ZF-S
5,0 kW
SKM 50 ZG-S
6,0 kW
SKM 60 ZG-S
7,1 kW
SKM 71 ZG-S
STM 25 ZF-S
Ducted
medium
Multisplit
Outdoor units
SRRM 25 ZF-S
4,0 kW
SCM 40 ZG-S
SRRM 35 ZF-S
4,5 kW
SCM 45 ZG-S
STM 50 ZF-S
SRRM 50 ZF-S
4,8 kW
SCM 48 ZG-S
STM 60 ZF-S
SRRM 60 ZF-S
6,0 kW
SCM 60 ZG-S
8,0 kW
SCM 80 ZG-S
15
Monosplit - Light Commercial
New DC Inverter Ultra Series
Wall-mounted
Movable air inlet panel
Automatic opening of the
front panel: the horizontal
swing helps the air suction,
minimizes the air resistance
and lowers the threshold of
sound levels. The flat shape
of the panel enhances the
modern and sophisticated
design of the unit.
SRK 20 ZIX-S
SRK 25 ZIX-S
SRK 35 ZIX-S
SRK 50 ZIX-S
SRK 60 ZIX-S
Wall mounted air-conditioners, 5 power capacities available
(2,0~6,0 kW)
Superlink II connection
The units can be connected
to RC-E3 wired remote
control and to Superlink II
system, thanks to the optional
interface kit SC-BIK-N-E and
SC-ADN-E interface.
Energy Class A, both in cooling and in heating
Long piping length: 30 m (5,0~6,0 kW model)
Low sound level: 21 dB(A) only (2,0 kW model)
Antibacterial treatment of the blower fan
Operation range in heating and cooling at an outdoor temperature
as low as -15°C
SRK 20 ZIX-S
SRC 20 ZIX-S
SRK 25 ZIX-S
SRC 25 ZIX-S
2,0 (0,9~3,1)
2,55 (0,9~3,2)
Power supply
SRK 35 ZIX-S
SRC 35 ZIX-S
SRK 50 ZIX-S
SRC 50 ZIX-S
SRK 60 ZIX-S
SRC 60 ZIX-S
5,0 (0,7~6,2)
6,0 (0,8~6,8)
1 Phase 220~240V 50Hz
Cooling capacity
kW
Heating capacity
kW
2,5 (0,9~4,3)
3,13 (0,9~4,7)
4,3 (0,9~5,1)
6,0 (0,7~8,8)
6,8 (0,8~9,7)
Power absorbtion in cool.
kW
0,35 (0,19~0,70)
0,49 (0,19~0,82)
0,845 (0,19~1,01)
1,30 (0,2~2,20)
1,86 (0,25~2,30)
Power absorbtion in heat.
kW
0,45 (0,23~1,00)
0,595 (0,23~1,12)
0,96 (0,23~1,35)
1,35 (0,2~2,26)
1,67 (0,25~2,70)
3,85
3,23
Energy class in cooling
A
Energy class in heating
A
EER
5,71
COP
4,14
5,56
5,26
4,48
4,44
4,07
1,9/1,8/1,7
2,5/2,4/2,3
4,0/3,8/3,6
6,0/5,7/5,5
8,5/8,2/7,8
(220-230-240)
A
2,4/2,3/2,2
3,1/2,9/2,8
4,6/4,4/4,2
6,2/5,9/5,7
7,7/7,3/7,0
Cool. (Hi)
CMM
11,5
12,5
Cooling (I.U.)
dB(A)
Hi 39 Me 30 Lo 21
Hi 41 Me 31 Lo 22
Hi 43 Me 33 Lo 22
Hi 45 Me 38 Lo 26
Hi 47 Me 38 Lo 26
(220-230-240)
Heating current
Sound pressure level
5,20
A
Cooling current
Air flow
3,5 (0,9~4,1)
13,5
14,5
Heating (I.U.)
dB(A)
Hi 38 Me 33 Lo 25
Hi 41 Me 34 Lo 27
Hi 42 Me 35 Lo 27
Hi 45 Me 38 Lo 32
Hi 45 Me 39 Lo 33
Cooling (O.U.)
dB(A)
47
47
50
48
51
Heating (O.U.)
dB(A)
47
47
50
48
51
Dimensions
(H*W*D)
I.U.
mm
O.U.
mm
590x780(+62)x290
Net weight
I.U./O.U.
kg
15/38
liquid line
mm(in)
gas line
mm(in)
Sound pressure level
Refrigerant piping size
Refrigerant
309x890x220
640x800(+71)x290
15/43
6,35 (1/4")
9,52 (3/8")
12,7 (1/2")
R410A
SRK 50~60 ZIX-S can be selected for use as indoor units in the combination with Twin, Triple and Double Twin system outdoor
units. Refer to the Commercial section for details.
16
New DC Inverter Ultra Series
Floor standing
Auto air outlet
selection
SRF 25 ZIX-S
SRF 35 ZIX-S
SRF 50 ZIX-S
Lower and upper outlets, in
cooling and heating, spread
comfort air to every corner.
In heating operation the
automatic adjustment of
lower air outlet direction
prevents the stirring up
of warm air and keeps
optimum comfort at floor
level.
Floor standing air-conditioners, 3 power capacities
available (2,5~5,0 kW)
Superlink II connection
Energy Class A, both in cooling and in heating
The units can be connected
to RC-E3 wired remote
control and to Superlink II
system, thanks to the optional
interface kit SC-BIK-N-E and
SC-ADN-E interface.
Long piping length: 30 m (5,0 kW model)
Low sound level: 26 dB(A) only (2,5 kW model)
Sophisticated and modern design
SRF 25 ZIX-S
SRC 25 ZIX-S
SRF 35 ZIX-S
SRC 35 ZIX-S
Power supply
SRF 50 ZIX-S
SRC 50 ZIX-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
Heating capacity
kW
3,4 (0,9~4,7)
4,5 (0,9~5,1)
6,0 (0,7~7,0)
Power absorbtion in cool.
kW
0,521 (0,19~0,82)
0,890 (0,19~1,26)
1,390 (0,2~1,80)
Power absorbtion in heat.
kW
0,723 (0,23~1,20)
1,124 (0,23~1,43)
1,540 (0,2~2,25)
2,5 (0,9~3,2)
3,5 (0,9~4,1)
Energy class in cooling
A
Energy class in heating
A
EER
4,80
COP
3,60
4,70
4,00
3,90
2,6/2,5/2,4
4,1/3,9/3,7
6,4/6,1/5,8
(220-230-240)
A
3,6/3,4/3,3
5,2/4,9/4,7
7,1/6,8/6,5
Cool. (Hi)
CMM
9
9,2
11,5
Cooling (I.U.)
dB(A)
Hi 38 Me 31 Lo 26
Hi 39 Me 33 Lo 28
Hi 45 Me 38 Lo 30
(220-230-240)
Heating current
Sound pressure level
3,93
A
Cooling current
Air flow
5,0 (0,7~5,5)
Heating (I.U.)
dB(A)
Hi 38 Me 34 Lo 28
Hi 39 Me 35 Lo 31
Hi 45 Me 38 Lo 32
Cooling (O.U.)
dB(A)
47
50
48
Heating (O.U.)
dB(A)
47
50
48
Dimensions
(H*W*D)
I.U.
mm
O.U.
mm
Net weight
I.U./O.U.
kg
liquid line
mm(in)
gas line
mm(in)
Sound pressure level
Refrigerant piping size
Refrigerant
600x860x238
590x780(+62)x290
18/38
640x800(+71)x290
19/38
19/43
6,35 (1/4")
9,52 (3/8")
12,7 (1/2")
R410A
17
Monosplit - Light Commercial
New DC Inverter Ultra Series
4-ways Cassette 84x84
New design of the
air louvers
FDT 40V
FDT 50V
FDT 60V
4 way cassette available in 3 power capacities
(4,0~5,6 kW)
According to room
temperature conditions,
4 directions of air flow
can be controlled
by individual flap as
preferred. As individual
flap control is available
even after installation,
installation area
becomes wider than
before.
Low Profile design
The new design of the
heat exchanger - reduced
from 2 components to a
single component - results
in decrease in the unit
height. Moreover, thanks
to the application of DC
fan motors, FDT units show
high energy efficiencies
levels, weight reduction
and a very compact
design.
Energy class A, both in heating and in cooling
Wireless Remote Control Kit with RCN-T-36W-E (optional)
Detachable covers at the four corners for easier
installation
Easy checking of condensate drain pan condition
Height reduction from 27 to
24,6 cm.
Operating range, in heating and cooling, with an outdoor
temperature as low as -15 °C
Standard condensate drain pump
FDT 40V
SRC 40 ZIX-S
FDT 50V
SRC 50 ZIX-S
Power supply
FDT 60V
SRC 60 ZIX-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
4,0 (1,8~4,7)
5,0 (2,2~5,6)
5,6 (2,8~6,3)
Heating capacity
kW
4,5 (2,0~5,4)
5,4 (2,5~6,3)
6,7 (3,1~7,1)
Power absorbtion in cool.
kW
0,93
1,29
1,57
Power absorbtion in heat.
kW
1,15
1,29
1,85
Energy class in cooling
A
Energy class in heating
A
EER
4,30
3,88
3,57
COP
3,91
4,19
3,62
Max running current
Air flow
Sound pressure level
Dimensions
(H*W*D)
A
12
14
I.U./O.U.
CMM
Hi 18 Me 16 Lo 14 / 40
I.U.
dB(A)
Hi 33 Me 31 Lo 30
O.U.
dB(A)
I.U./panel
mm
246x840x840 / 35x950x950
U.E.
mm
640x800(+71)x290
Panel/remote control
47
48
T-PSA-36W-E, RCN-T-36W-E; RC-E3, RCH-E3
Net weight
I.U./O.U.
kg
Net weight
panel
kg
5,5
liquid line
mm(in)
6,35 (1/4")
gas line
mm(in)
12,7 (1/2")
Refrigerant piping size
18
22/45
24/45
New DC Inverter Ultra Series
4-ways Cassette 60x60
Low Profile design
Ultra slim design with only 24,8
cm height: ideal for installation
in modular ceilings.
FDTC 40V
FDTC 50V
Air flow
The new shape and design of
the louver help in redirecting
the air flow away from the
ceiling, to reduce ceiling stains.
4 way cassette available in 2 power capacities (4,0~5,0 kW)
Energy class A, both in heating and in cooling
Wireless Remote Control Kit with RCN-TC-24W-ER (optional)
Detachable covers at the four corners for easier installation
Extremely high splitting distance: 30 m
Ideal for installation in modular ceilings
Operating range, in heating and cooling, with an outdoor
temperature as low as -15 °C
Standard condensate drain pump
FDTC 40V
SRC 40 ZIX-S
Power supply
FDTC 50V
SRC 50 ZIX-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
4,0 (1,8~4,7)
5,0 (2,2~5,6)
Heating capacity
kW
4,5 (2,0~5,4)
5,4 (2,5~6,3)
Power absorbtion in cool.
kW
1,04
1,56
Power absorbtion in heat.
kW
1,10
1,45
Energy class in cooling
A
Energy class in heating
A
EER
3,85
3,21
COP
4,09
3,72
Max running current
Air flow
Sound pressure level
Dimensions
(H*W*D)
A
12
14
I.U./O.U.
CMM
Hi 11,5 Me 10 Lo 8 / 40
I.U.
dB(A)
Hi 42 Me 38 Lo 35
O.U.
dB(A)
47
I.U./panel
mm
248x570x570 / 35x700x700
U.E.
mm
640x800(+71)x290
Panel/remote control
TC-PSA-24W-ER, RCN-TC-24W-ER; RC-E3, RCH-E3
Net weight
I.U./O.U.
kg
15/45
Net weight
panel
kg
3,5
liquid line
mm(in)
6,35 (1/4")
gas line
mm(in)
12,7 (1/2")
Refrigerant piping size
19
Monosplit - Light Commercial
New DC Inverter Ultra Series
Ceiling suspended
Compact design
Easy and fast installation with
only 21 cm height and 30 kg
net weight (4,0~5,0 kW units).
FDEN 40V
FDEN 50V
FDEN 60V
Installation Flexibility
Flexible installation: the
refrigerant pipework can be
installed in three different
positions (on the back, on the
top, to the right) as well as the
drain pipework (on the left or
right).
Ceiling suspended available in 3 power capacities
(4,0~5,6 kW)
Energy class A, both in heating and in cooling
(4,0 kW model)
Extremely high splitting distance: 30 m
Top
Suitable for large spaces due to the powerful airflow
Back
Operating range, in heating and cooling, with an
outdoor temperature as low as -15 °C
Right
FDEN 40V
SRC 40 ZIX-S
FDEN 50V
SRC 50 ZIX-S
Power supply
FDEN 60V
SRC 60 ZIX-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
4,0 (1,8~4,7)
5,0 (2,2~5,6)
5,6 (2,8~6,3)
Heating capacity
kW
4,5 (2,0~5,4)
5,4 (2,5~6,3)
6,7 (3,1~7,1)
Power absorbtion in cool.
kW
1,04
1,59
1,95
Power absorbtion in heat.
kW
1,13
1,58
2,12
Energy class in cooling
A
B
C
Energy class in heating
A
B
D
EER
3,85
3,14
2,87
COP
3,98
3,42
3,16
Max running current
Air flow
A
12
14
I.U./O.U.
CMM
Hi 11 Me 9 Lo 7 / 40
Hi 18 Me 14 Lo 12 / 40
I.U.
dB(A)
Hi 39 Me 38 Lo 37
Hi 41 Me 39 lo 38
O.U.
dB(A)
47
48
I.U.
mm
210x1070x690
210x1320x690
O.U.
mm
Net weight
I.U.
kg
Net weight
O.U.
kg
45
liquid line
mm(in)
6,35 (1/4")
gas line
mm(in)
12,7 (1/2")
Sound pressure level
Dimensions
(H*W*D)
Refrigerant piping size
Control
20
640x800(+71)x290
30
36
RC-E3, RCH-E3, RCN-E1R
New DC Inverter Ultra Series
Ducted medium
Standard drain pump
(60 cm)
FDUM 50V
Standard drain pump with 60
cm from the base of the unit
allows for greater flexibility in
layout and installation.
FDUM 60V
Ducted air-conditioning unit available in 2 power capacities (5,0~5,6 kW)
Energy class A, both in heating and in cooling (5,0 kW model)
Extremely high splitting distance: 30 m
Ultra-compact design: only 29,9 cm height
Perfect for small/medium rooms
Flexible hose
less than
Operating range, in heating and cooling, with an outdoor
temperature as low as -15 °C
600 mm
Filter kit (optional) UM-FL1E (FDUM 50V), UM-FL2E (FDUM 60V)
FDUM 50V
SRC 50 ZIX-S
Power supply
FDUM 60V
SRC 60 ZIX-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
5,0 (2,2~5,6)
5,6 (2,8~6,3)
Heating capacity
kW
5,4 (2,5~6,3)
6,7 (3,1~7,1)
Power absorbtion in cool.
kW
1,52
1,86
Power absorbtion in heat.
kW
1,41
1,96
Energy class in cooling
A
B
Energy class in heating
A
B
EER
3,29
3,01
COP
3,83
3,42
Max running current
Air flow
A
14
I.U./O.U.
CMM
I.U.
dB(A)
O.U.
dB(A)
47
48
I.U.
mm
299x750x635
299x950x635
O.U.
mm
Net weight
I.U.
kg
Net weight
O.U.
kg
45
Pa
Standard 50
Max 85
liquid line
mm(in)
6,35 (1/4")
gas line
mm(in)
12,7 (1/2")
Pressione sonora
Dimensions
(H*W*D)
Available Static Pressure
Refrigerant piping size
Hi 14 Me 12 Lo 11 / 40
Hi 18 Me 16 Lo 14 / 40
Hi 34 Me 31 Lo 28
640x800(+71)x290
34
40
21
Monosplit
DC Inverter Hyper Series
Wall-mounted
SRK 20 ZGX-S
SRK 25 ZGX-S
SRK 35 ZGX-S
SRK 50 ZGX-S
SRK 71 ZE-S1
Wall-mounted units, available in 5 power
capacities (2,0~7,1 kW)
Energy Class A, both in cooling and in heating
Particularly high splitting distance: 25 m
(5,0 kW model) and 30 m (7,1 kW model)
Allergen Clear function, to sanitize against
allergens, switchable from the remote control
(7,1 kW model)
Operating range, in heating and cooling, with an
outdoor temperature as low as -15 °C
Connectable to the RC-E1R wired remote
control and to Superlink system, thanks to
SC-AD-ER interface (7,1 kW model)
Low noise level: 21 dB(A) only
(2,0~2,5 kW models)
Antibacterial treatment of the fan blades
ZE-S1
SRK 20 ZGX-S
SRC 20 ZGX-S
SRK 25 ZGX-S
SRC 25 ZGX-S
2,0 (0,5~2,8)
2,5 (0,5~3,0)
Power supply
SRK 35 ZGX-S
SRC 35 ZGX-S
SRK 50 ZGX-S
SRC 50 ZGX-S
SRK 71 ZE-S1
SRC 71 ZE-S1
5,0 (0,6~5,3)
7,1 (0,9~8,0)
1 Phase 220~240V 50Hz
Cooling capacity
kW
Capacità in risc.
kW
2,4 (0,5~4,6)
3,0 (0,5~5,0)
4,2 (0,5~5,1)
6,0 (0,6~7,9)
8,0 (0,9~10,5)
Power absorbtion in cool.
kW
0,37 (0,10~0,91)
0,50 (0,10~0,64)
0,87 (0,10~0,98)
1,56 (0,12~2,1)
2,21 (0,32~2,98)
Power absorbtion in heat.
kW
0,44 (0,09~1,27)
0,59 (0,09~1,16)
1,00 (0,09~1,19)
1,66 (0,11~2,71)
2,21 (0,26~3,75)
3,5 (0,5~3,9)
Energy class in cooling
A
Energy class in heating
A
EER
5,41
COP
3,21
5,45
5,08
4,20
3,61
3,62
2,1/2,0/1,9
2,5/2,4/2,3
4,2/4,0/3,8
7,5/7,2/6,9
10,1/9,7/9,3
(220-230-240)
A
2,5/2,4/2,3
2,9/2,8/2,7
4,9/4,7/4,5
7,9/7,6/7,3
10,1/9,7/9,3
Cool. (Hi)
CMM
12
12,5
20
Cooling (I.U.)
dB(A)
Hi 42 Me 34 Lo 21
Hi 43 Me 34 Lo 21
Hi 44 Me 35 lo 22
Hi 45 Me 38 Lo 26
Hi 45 Me 40 Lo 26
(220-230-240)
Heating current
Sound pressure level
4,02
A
Cooling current
Air flow
5,00
11,8
Heating (I.U.)
dB(A)
Hi 42 Me 35 Lo 25
Hi 43 Me 36 Lo 26
Hi 44 Me 37 Lo 27
Hi 47 Me 39 Lo 34
Hi 46 Me 40 Lo 27
Cooling (O.U.)
dB(A)
44
45
47
48
52
Heating (O.U.)
dB(A)
43
47
50
50
Dimensions
(H*W*D)
I.U.
mm
O.U.
mm
540x780x290
640x850x290
Net weight
I.U./O.U.
kg
12/38
12/43
liquid line
mm(in)
gas line
mm(in)
Sound pressure level
Refrigerant piping size
Refrigerant
22
298x840x259
49
381x1098x248
6,35 (1/4")
750x880x340
18/65
6,35 (1/4")
9,52 (3/8")
12,7 (1/2")
R410A
15,88 (5/8")
DC Inverter Flat Series
Wall-mounted
SRK 20 ZG-S
SRK 25 ZG-S
SRK 35 ZG-S
SRK 50 ZG-S
Wall-mounted units available in 4 power
capacities (2,0~5,0 kW)
Allergen Clear Function, to sanitize against
allergens, switchable from the remote control
Energy class A, both in heating and in cooling
(2,0~3,5 kW models)
Operating range, in heating and cooling, with an
outdoor temperature as low as -15 °C
Particularly high splitting distance: 25 m
(5,0 kW model)
Connectable to the RC-E1R wired remote
control and to Superlink system, thanks to
optional SC-BIK-E kit and SC-AD-ER interface
Ultra slim panel: 19,9 cm deep only
Low noise level: 21 dB(A) only (2,0 kW model)
SRK 20 ZG-S
SRC 20 ZG-S
SRK 25 ZG-S
SRC 25 ZG-S
2,0 (0,5~2,8)
2,5 (0,5~3,0)
Power supply
SRK 35 ZG-S
SRC 35 ZG-S
SRK 50 ZG-S
SRC 50 ZG-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
Capacità in risc.
kW
2,7 (0,5~4,6)
3,4 (0,5~4,8)
4,2 (0,5~5,1)
5,8 (0,6~7,9)
Power absorbtion in cool.
kW
0,44 (0,10~0,91)
0,62 (0,10~0,97)
1,05 (0,10~1,22)
1,66 (0,12~2,10)
Power absorbtion in heat.
kW
0,62 (0,09~1,27)
0,93 (0,09~1,30)
1,14 (0,09~1,32)
1,70 (0,11~2,71)
Energy class in cooling
A
Energy class in heating
4,55
COP
B
4,03
3,33
3,01
4,35
3,66
3,68
3,41
A
2,4/2,3/2,2
3,1/3,0/2,9
4,9/4,7/4,5
7,6/7,3/7,0
(220-230-240)
A
3,0/2,9/2,8
4,5/4,3/4,1
5,3/5,1/4,9
7,9/7,5/7,2
Cool. (Hi)
CMM
7,4
7,6
8,5
11,5
Cooling (I.U.)
dB(A)
Hi 35 Me 29 Lo 21
Hi 36 Me 30 Lo 22
Hi 40 Me 32 Lo 23
Hi 47 Me 42 Lo 26
Cooling current
(220-230-240)
Heating current
Sound pressure level
5,0 (0,6~5,3)
B
A
EER
Air flow
3,5 (0,5~3,9)
Heating (I.U.)
dB(A)
Hi 35 Me 32 lo 25
Hi 36 Me 33 Lo 26
Hi 41 Me 36 Lo 27
Hi 48 Me 40 Lo 34
Cooling (O.U.)
dB(A)
44
44
48
48
Heating (O.U.)
dB(A)
45
47
50
50
Dimensions
(H*W*D)
I.U.
mm
O.U.
mm
Net weight
I.U./O.U.
kg
liquid line
mm(in)
gas line
mm(in)
Sound pressure level
Refrigerant piping size
Refrigerant
268x790x199
540x780(+62)x290
640x850(+65)x290
8,5/35
8,5/38
8,5/43
6,35 (1/4")
9,52 (3/8")
12,7 (1/2")
R410A
23
Monosplit
DC Inverter Smart Series
Wall-mounted
SRK 25 ZDX-S
Wall-mounted units, available in 1 power
capacity (2,5 kW)
Low noise level: 21 dB(A) only
Energy class A in heating and cooling
Rounded-off design
Anti-bacterial treatment of the fan blades
Operating range, in heating and cooling, with an
outdoor temperature as low as -10 °C
SRK 25 ZDX-S
SRC 25 ZDX-S
Power supply
1 Phase 220~240V 50Hz
Cooling capacity
kW
Capacità in risc.
kW
3,0 (0,5~5,0)
Power absorbtion in cool.
kW
0,50 (0,10~0,64)
Power absorbtion in heat.
kW
0,59 (0,09~1,16)
Energy class in cooling
A
Energy class in heating
A
EER
5,00
COP
5,08
Cooling current
(220-230-240)
Heating current
Air flow
Sound pressure level
2,5 (0,5~3,0)
A
2,5/2,4/2,3
(220-230-240)
A
2,9/2,8/2,7
Cool. (Hi)
CMM
11,8
Cooling (I.U.)
dB(A)
Hi 43 Me 34 Lo 21
Heating (I.U.)
dB(A)
Hi 43 Me 36 Lo 26
Cooling (O.U.)
dB(A)
45
Heating (O.U.)
dB(A)
47
Dimensions
(H*W*D)
I.U.
mm
298x840x259
O.U.
mm
540x720x290
Net weight
I.U./O.U.
kg
12/35
liquid line
mm(in)
6,35 (1/4")
gas line
mm(in)
9,52 (3/8")
Sound pressure level
Refrigerant piping size
Refrigerant
24
R410A
Constant Speed Series
Wall-mounted
SRK 20 HG-S
SRK 28 HG-S
SRK 40 HG-S
SRK 56 HE-S1
Wall-mounted units, available in 4 power
capacities (2,07~5,1 kW)
Extremely high splitting distance: 15 m (2,07~2,6
and 3,6 kW models) and 25 m (5,1 kW model)
Energy class A in heating and cooling
(2,07~2,6 and 5,1 kW models)
Bidirectional ventilation (5,1 kW model)
Operating range, in heating and cooling, with an
outdoor temperature as low as -5 °C
SRK 20 HG-S
SRC 20 HG-S
SRK 28 HG-S
SRC 28 HG-S
2,6
3,6
Power supply
SRK 40 HG-S
SRC 40 HG-S
SRK 56 HE-S1
SRC 56 HE-S1
1 Phase 220~240V 50Hz
Cooling capacity
kW
2,07
Capacità in risc.
kW
2,22
2,8
3,92
5,8
Power absorbtion in cool.
kW
0,64
0,81
1,12
1,59
Power absorbtion in heat.
kW
0,61
0,77
1,15
1,58
Energy class in cooling
A
Energy class in heating
A
EER
3,23
COP
B
A
3,21
3,21
3,64
3,64
3,41
3,67
3,1/3,0/2,9
3,8/3,7/3,6
5,3/5,2/5,1
7,3/7,1/6,8
(220-230-240)
A
3,0/2,9/2,8
3,7/3,5/3,3
5,4/5,3/5,2
7,4/7,1/6,8
Cool. (Hi)
CMM
7,5
8,5
9
12,5
Cooling (I.U.)
dB(A)
Hi 34 Me 30 Lo 27
Hi 39 Me 33 Lo 30
Hi 40 Me 38 Lo 34
Hi 44 Me 40 Lo 35
(220-230-240)
Heating current
Sound pressure level
3,21
A
Cooling current
Air flow
5,1
Heating (I.U.)
dB(A)
Hi 34 Me 31 lo 27
Hi 40 Me 33 Lo 29
Hi 40 Me 38 Lo 34
Hi 44 Me 39 Lo 35
Cooling (O.U.)
dB(A)
46
46
49
49
Heating (O.U.)
dB(A)
46
46
52
Dimensions
(H*W*D)
I.U.
mm
O.U.
mm
Net weight
I.U./O.U.
kg
liquid line
mm(in)
gas line
mm(in)
Sound pressure level
Refrigerant piping size
Refrigerant
51
268x790x199
298x840x259
540x780(+62)x290
8,5/29
640x850(+65)x290
8,5/31
8,5/38
12/44
6,35 (1/4")
9,52 (3/8")
12,7 (1/2")
R410A
25
Multisplit
SKM ZG-S Series
SKM 20 ZG-S
SKM 22 ZG-S
SKM 25 ZG-S
SKM 28 ZG-S
SKM 35 ZG-S
SKM 50 ZG-S
Wall-mounted units, available in 8 power
capacities (2,00~7,10 kW)
Connectable to RC-E1R wired remote control
and to Superlink system, thanks to optional
SC-BIK-E kit and SC-AD-ER interface
Operating range, in heating and cooling, with
an outdoor temperature as low as -15 °C
SKM 20 ZG-S
SKM 22 ZG-S
Power supply
SKM 25 ZG-S
SKM 28 ZG-S
SKM 35 ZG-S
SKM 50 ZG-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
2,0
2,2
2,5
2,8
3,5
5,0
Heating capacity
kW
3,0
3,2
3,4
4,0
4,5
5,8
Sound pressure level
Air flow
Cooling
dB(A)
Heating
dB(A) Hi 37 Me 32 Lo 27Hi 38 Me 33 Lo 27 Hi 38 Me 33 Lo27 Hi 40 Me 34 Lo 28Hi 41 Me 35 Lo 29Hi 44 Me 39 Lo 33
Cool. (Hi)
CMM
Dimensions (H*W*D)
Net weight
Refrigerant piping size
Hi 35 Me29 Lo23 Hi 36 Me 30 Lo 23 Hi 36 Me 30 lo 24 Hi 38 Me 31 Lo 24 Hi 39 Me 32 lo 25 Hi 45 Me 36 Lo 25
7,5
7,8
8,3
mm
268x790x199
kg
8,5
liquid line
mm(in)
gas line
mm(in)
8,8
11,3
6,35 (1/4")
O.U. connectable
9,52 (3/8")
12,7 (1/2")
SCM 40, 45, 48, 60, 80 ZG-S
SCM 60, 80 ZG-S
Connectable to RC-E1R wired remote control
and to Superlink system, thanks to
SC-AD-ER interface
SKM 60 ZG-S
SKM 71 ZG-S
SKM 60 ZG-S
Power supply
SKM 71 ZG-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
6,0
7,1
Heating capacity
kW
6,8
8,0
Cooling/Heating
dB(A)
Hi 43 Me 36 Lo 26 / Hi 43 Me 37 Lo 27
Hi 44 Me 34 Lo 26 / Hi 44 Me 38 Lo 27
Cool. (Hi)
CMM
18
19
Sound pressure level
Air flow
Dimensions (H*W*D)
mm
318x1098x248
kg
15
liquid line
mm(in)
6,35 (1/4")
gas line
mm(in)
Net weight
Refrigerant piping size
O.U. connectable
26
12,7 (1/2")
SCM 60, 80 ZG-S
SCM 80 ZG-S
STM ZF-S; SRRM ZF-S Series
4-ways Cassette 60x60
4-way Cassette units, for modular ceilings,
available in 4 power capacities (2,50~6,00 kW)
TTP42-W-E standard panel
Connectable to RC-E1R wired remote control
and to Superlink system, thanks to SC-AD-ER
interface
Drain pump up to 60 cm from lower indoor
unit’s profile
STM 25 ZF-S
STM 35 ZF-S
STM 50 ZF-S
STM 60 ZF-S
STM 25 ZF-S
STM 35 ZF-S
Power supply
STM 50 ZF-S
STM 60 ZF-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
2,5
3,5
5,0
6,0
Heating capacity
kW
3,4
4,5
5,8
6,8
Cooling
dB(A)
Hi 35 Me 33 Lo 31
Hi 38 Me 35 lo 33
Hi 40 Me 38 lo 35
Hi 47 Me 43 Lo 39
Heating
dB(A)
Hi 35 Me 33 Lo 31
Hi 38 Me 35 Lo 33
Hi 40 Me 38 Lo 35
Hi 47 Me 43 Lo 39
Air flow (Hi)
Cool./heat.
CMM
8,0/9,0
9,0/10,0
10,0/11,0
13,0/14,0
Dimensions (H*W*D)
I.U./panel
mm
Net weight
I.U./panel
kg
Refrigerant piping size
liquid line
mm(in)
gas line
mm(in)
Sound pressure level
O.U. connectable
Ducted medium
248x570x570 / 35x700x700
14/3,5
14,5/3,5
6,35 (1/4")
9,52 (3/8")
12,7 (1/2")
SCM 40, 45, 48, 60, 80 ZG-S
SCM 60, 80 ZG-S
Accessories (optional)
Low and medium head duct type units, available in 4
power capacities (2,50~6,00 kW)
RDU 12E
RTS 12
Drain pump
Recovery grille from below
RFJ 22
RBF 12
2-way ducts
Recovery filter
Compact dimensions: 23 cm high only
Connectable to RC-E1R wired remote control and to
Superlink system, thanks to SC-AD-ER interface
SRRM 25 ZF-S
SRRM 35 ZF-S
SRRM 50 ZF-S
SRRM 60 ZF-S
SRRM 25 ZF-S
SRRM 35 ZF-S
kW
2,5/3,4
3,5/4,5
5,0/5,8
6,0/6,8
Power supply
SRRM 50 ZF-S
SRRM 60 ZF-S
1 Phase 220~240V 50Hz
Cool./heat. capacity
Cooling
dB(A)
Hi 38 Me 32 Lo 25
Hi 40 Me 35 Lo 28
Hi 46 Me 40 Lo 31
Hi 49 Me 42 Lo 33
Heating
dB(A)
Hi 39 Me 34 Lo 27
Hi 41 Me 37 Lo 30
Hi 46 Me 43 Lo 34
Hi 49 Me 45 Lo 36
Air flow (Hi)
Cool./heat.
CMM
8,5/10,0
9,0/11,0
10,5/13,0
12,5/15,0
Available Static Pressure
Cool./heat.
Pa
18/26
20/30
30/45
45/60
Sound pressure level
Dimensions (H*W*D)
mm
Net weight
Refrigerant piping size
O.U. connectable
kg
liquid line
mm(in)
gas line
mm(in)
230x740x455
22
23
6,35 (1/4")
9,52 (3/8")
12,7 (1/2")
SCM 40, 45, 48, 60, 80 ZG-S
SCM 60, 80 ZG-S
27
Multisplit
Outdoor units
SCM 40 ZG-S
SCM 45 ZG-S
SCM 48 ZG-S
SCM 60 ZG-S
Outdoor units available in 2 models and 5 different power
capacities (4,00~8,00 kW)
Low noise level: 25 dB(A) (4,00~4,50 kW)
Operating range, in heating and cooling, with an outdoor
temperature as low as -15 °C
SCM 80 ZG-S
Pipes connections
level
difference
SCM 40 ZG-S
SCM 45 ZG-S
SCM 48 ZG-S
SCM 60 ZG-S
SCM 80 ZG-S
Length for one indoor unit
25 m
25 m
25 m
25 m
25 m
Total length for all rooms
30 m
30 m
40 m
40 m
70 m
Lowest outdoor unit’s installation point
15 m
15 m
15 m
15 m
20 m
Highest outdoor unit’s installation point
15 m
15 m
15 m
15 m
20 m
Max. height difference among indoor units
25 m
25 m
25 m
25 m
25 m
Refrigerant pipes’ length without additional charge
30 m
20 m
40 m
30 m
40 m
for 2 rooms
SCM 40 ZG-S
for 2 rooms
SCM 45 ZG-S
Power supply
for 3 rooms
SCM 48 ZG-S
for 3 rooms
SCM 60 ZG-S
for 4 rooms
SCM 80 ZG-S
1 Phase 220~240V 50Hz
Cooling capacity
kW
4,0 (1,9~5,0)
4,5 (1,0~6,4)
4,8 (1,1~6,9)
6,0 (1,1~7,5)
8,0 (1,8~9,5)
Heating capacity
kW
5,0 (2,2~5,2)
5,6 (1,8~6,8)
6,0 (1,4~7,1)
7,0 (1,4~7,6)
9,3 (0,8~9,6)
EER
4,12
3,78
4,03
3,70
3,60
COP
4,35
4,15
4,35
4,02
3,83
Energy class in cooling
A
Energy class in heating
Sound pressure level
A
Cooling
dB(A)
45
45
48
48
51
Heating
dB(A)
47
47
49
50
52
Dimensions
(H*W*D)
mm
Net weight
kg
Compressor type
Refrigerant piping size
640x850(+65)x290
44
46
Rotary x 1
liquid line
mm(in)
gas line
mm(in)
51
66
Twin Rotary x 1
6,35 (1/4") x 2
9,52 (3/8") x 2
6,35 (1/4") x 3
9,52 (3/8") x 3
6,35 (1/4") x 4
9,52 (3/8") x 4
R410A
SKM 20~35 ZG-S STM 25, 35 ZFS SRRM 25, 35 ZFS
Connectable I.U.
28
46
Scroll x 1
Refrigerant
Total of indoor unit
750x880(+73)x340
kW
5,7
7,0
8,5
SKM 20~60 ZG-S
STM 25~60 ZFS
SRRM 25~60 ZFS
SKM 20~71 ZG-S
STM 25~60 ZFS
SRRM 25~60 ZFS
11,0
13,5