1.4(A1)
AX-DV, AX-DVF
Video Door Stations for AX Series
AX-DVF
AX-DV
DESCRIPTION:
The AX-DV is a surface mount color video door
station for the AX Series. The AX-DVF is a flush
mount color video door station. Both units wire
directly to the AX Central Exchange Unit using
CAT-5e wire with an RJ45 jack for connection.
The AX-DV has an aluminum die cast cover.
The AX-DVF has a stainless steel faceplate.
Both units include a camera, microphone,
speaker, and call button. Tamper resistant
screws are provided for mounting.
When the call button on the door station is
pushed, the master station(s) ring and the video
monitor comes on with the image from the door
station’s camera. The master station user then
pushes the “TALK” button to initiate
communication. The person at the door station
speaks hands-free.
FEATURES:
Color video camera with audio intercom
2-way hands-free voice communication with AX
master station
Call button to initiate call to master(s)
White LED illuminator for low light conditions
RJ45 jack for easy CAT-5e connection
Surface (AX-DV) or flush mount (AX-DVF) styles
available
980' wiring distance from CEU on CAT-5e cable
The AX door stations can be located up to 980'
from the AX CEU and wired with CAT-5e cable.
Additional equipment is available to interface
with third party hardware for transmission over
fiber optic cable or an IP network.
AX-DV,DVF Spec Sheet
0409 Pg. 1
Aiphone Corporation
1700 130th Ave NE * Bellevue, WA 98005
Ph: (800) 692-0200 * Fax: (425) 455-0071
tech@aiphone.com
AX-DV, AX-DVF
Video Door Stations for AX Series
FEATURE CALL-OUTS:
FEATURE CALL-OUT DEFINITIONS:
[1] Call Button
[2] Speaker
[3] Microphone
[4] Camera
[5] Directory Card
[6] White LED illuminators
[6]
SPECIFICATIONS:
Power Source:
24V DC Supplied from CEU
Wiring connection: RJ45 jack (CAT-5e)
[6]
PACKAGE CONTENTS:
Communication:
Hands-free communication
(auto-voice actuated or PTT)
controlled by master station
Camera:
¼” color CCD camera
Pixels:
250,000 Pixels
Minimum
illumination:
5 Lux
Operating temp:
14 – 140° F (-10 ~ 60° C)
Mounting:
AX-DV
AX-DVF
Surface wall mount
Flush mount (with provided box)
[1] Vandal resistant door
station (AX-DV, AX-DVF)
Housing:
AX-DV
[2] Special screwdriver
AX-DVF
[3] Directory card
[4] Mounting screws and
Anchor bolts (AX-DV)
[5] Mounting screws
(AX-DVF)*
Dimensions:
[6] Back box (AX-DVF)*
(HxWxD)
* [5] and [6] are packed
with AX-DVF only
AX-DV,DVF Spec Sheet
0409 Pg. 2
Color:
AX-DV
AX-DVF
Weight:
(approx.)
Front Panel: Aluminum die cast
Main Unit: Resins
Front Panel: Stainless steel
Main Unit: Resins
Back box: Steel plate
Solid silver (metallic gray)
Stainless steel, brush-finished
AX-DV: 7-11/16" x 3-15/16" x 1"
(195x100x25 mm)
AX-DVF: 9-11/16" x 5-¾” x 1-7/8"
(246x146x45 mm)
AX-DV: 0.88 lbs (400g)
AX-DVF: 1.45lbs (660g)
Aiphone Corporation
1700 130th Ave NE * Bellevue, WA 98005
Ph: (800) 692-0200 * Fax: (425) 455-0071
tech@aiphone.com
1.4(A2)
AX-8MV
Audio Video Master Station for AX Series
AX-8MV
DESCRIPTION:
The AX-8MV Master Station is the centerpiece of
the AX Integrated Audio & Video Security system.
Each AX-8MV master station can initiate and
answer calls from up to 7 additional master stations
and up to 8 door or sub stations. The master can be
expanded with AX-16SW add-on selectors for a
maximum capacity of 120 door / sub stations. Its
streamline design is mountable on a wall or desk.
When a video door station calls, a tremolo tone
rings and the 3.5" color monitor comes on,
displaying the image from the door station location.
To answer the call, simply press the TALK button
once and speak hands-free, or Press and Hold the
TALK button to use as push-to-talk, release-tolisten. If access control is included, simply press the
“key” button and the associated electric strike or
magnetic lock will be activated.
Each master station connects via CAT-5e cable
homerun to the AX Central Exchange Unit. Feature
and operation variables are set with the system setup software and uploaded to the CEU.
White version is available, model AX-8MV-W.
AX-8MV Spec Sheet
0708 Pg. 1
FEATURES:
3.5" TFT color video monitor
8 master station channels
8 door / sub station channels
LED and call tone annunciation for programmable
length or infinite call-in
Hands-free VOX communication or Push-to-Talk
All Call to other master stations
Selective calling to any station in the system
Add-on selectors in increments of 16 channels for
max. capacity of 120 door / sub stations (CEU
capacity also req’d)
Privacy prevents other masters from listening in
CO Transfer allows calls to transfer to a telephone
number (Viking K-1900-5 required)
Scan Monitor allows listening to door / sub
stations in programmed time increments
Door release button activates door strike or
magnetic lock (selectable N/O or N/C contacts
from CEU)
3.5mm speaker & mic jacks for computer-style
headset or handset connection
Tone and volume adjustments for open voice and
headset communication
Brightness and contrast adjustments for video
Option connector for video output, call extension,
or footswitch operation of TALK function
Aiphone Corporation
1700 130th Ave NE * Bellevue, WA 98005
Ph: (800) 692-0200 * Fax: (425) 455-0071
tech@aiphone.com
AX-8MV
Audio Video Master Station for AX Series
FEATURE CALL-OUTS:
FEATURE CALL-OUT DEFINITIONS:
[1] Door station selector button w/LED
[2] Master station selector button w/LED
[3] Door release button
[4] Scan monitor button w/LED
[5] CO transfer button w/LED
[6] Privacy button w/LED
[7] TALK button w/LED
[8] ALL CALL button
[9] OFF button (standby)
[10] Occupied LED
[11] Speaker
[12] Microphone
[13] 3.5 inch color LCD monitor
[14] Receive volume control switch (low, med, high)
[15] Transmit volume control switch (low, med, high)
[16] Tone volume control
[17] LCD brightness control
[18] Headset receiver jack
[19] Headset microphone jack
[20] Master station directory card / card cover
[21] Door station directory card / card cover
[22] Desktop stand
[23] Headset receiver volume control
[24] Headset microphone volume control
[25] Reset switch
[26] RJ45 jack for wiring to CEU
[27] Optional connector input
[28] Connector for AX-16SW add-on selector
AX-8MV with optional desk stand:
Model MCW-S/A (adjustable to 45° or 60° angle)
AX-8MV Spec Sheet
0708 Pg. 2
SPECIFICATIONS:
Power Source:
24V DC Supplied from CEU
Call Tone:
Tremolo ring tone & blinking LED
Communication: Open voice hands-free
(VOX or Push-to-Talk)
Video Monitor:
3-½” direct view TFT color LCD
Scanning Lines:
525 lines
Video Output:
NTSC Standard 1Vpp (0.7-1.4Vpp)
Headset Jack:
3.5mm mic and speaker jacks
Calling Capacity: Up to 7 additional master stations
Up to 120 door / sub stations
Mounting:
Desk with flip-up stands, or wall
mount with provided metal bracket
Wall mount box: 2-gang electrical box or ring
Wiring:
CAT-5e homerun to CEU
Wiring Connection: RJ45 jack
Housing:
ABS Resin
Color:
Black
Operating Temp: 32 – 104° F (0 ~ 40° C)
Dimensions (HxWxD):
6-7/8" x 7-5/8" x 1-7/8"
(175 x 194 x 48 mm)
Weight:
1.21 lbs (550g)
Aiphone Corporation
1700 130th Ave NE * Bellevue, WA 98005
Ph: (800) 692-0200 * Fax: (425) 455-0071
tech@aiphone.com
0711
MCW-S/A
Desk Mount Stand
Use with:
AX, JA, JF, JK, KB, KC, and GT Systems
-INSTRUCTIONSThe MCW-S/A is a stand that will allow you to locate an Aiphone monitor station on a desk or tabletop. This
stand has two angle settings, enabling the user to select the optimal mounting angle for the monitor station (45°
or 60°).
45° Angle
60° Angle
MCW-S/A
JK-1MED on MCW-S/A
(shown at 60°)
Dimensions:
Faceplate: 4½” W x 6½” H
Base: 4½” W x 7⅞” D
Height at 45°: 5⅛”
Height at 60°: 6”
Recommended mounting
hole posistion by system:
Top:
Bottom:
AX
GT
JA
JF
KB
JK
KC
MOUNTING:
1. Attach the intercom’s mounting bracket to the MCW-S/A utilizing the appropriate set of mounting holes (Mounting hardware is not provided by Aiphone. Use 8/32” machine thread screw with flat washer and nut).
2. Set the angle of the MCW-S/A by adjusting the rear support arm for either a 45° or 60° angle.
3. Lock the rear support arm into position to prevent the MCW-S/A from collapsing.
4. Feed the wires through the back of the MCW-S/A and attach to the intercom unit.
5. Mount the station onto the mounting bracket.
AX-8MV on MCW-S/A
(shown at 45°)
Aiphone Corporation
1700 130th AVE NE
Bellevue, WA 98005
(425) 455-0510
Fax (425) 455-0071
GT-2C on MCW-S/A
(shown at 60°)
Toll Free Technical Support:
1-800-692-0200
E-mail: tech@aiphone.com
KB-3MRD on MCW-S/A
(shown at 60°)
MCW-S/A Instr.
0711JD
1.4(A3)
AX-084C
Central Exchange Unit for AX Series
DESCRIPTION:
The AX-084C is a Central Exchange Unit for the AX
Integrated Audio & Video Security system. Audio/
Video and/or Audio-only Master or Door Stations
connect directly to this unit via homerun CAT-5e
wiring and RJ45 jacks.
The AX-084C supports up to 4 Master Stations and
up to 8 Door/Sub stations. The AX-084C can be
expanded in increments of 32 for up to 104 Door/
Sub stations with the use of AX-320C add-on
CEU’s.
The CEU handles the calling and communication
signals for the system, as well as providing selective
door release outputs, video outputs, DVR trigger
outputs, and CO line transfer output. System set-up
and a variety of functions are programmed in the
CEU with the use of the supplied software. Power is
applied directly to the CEU via two PS-2420UL
power supplies. The serial connection is for
uploading the system programming, for raw RS232
data output, or for system monitoring via the
supplied program.
FEATURES:
Wiring hub for AX system using CAT-5e cable
Controls all functionality of AX system
4 Master station ports (RJ45)
8 Door / sub station ports (RJ45)
2 24V DC power supply input terminals
8 Door release dry contacts (24V AC/DC 500mA)
2 BNC composite video outputs and video
switching triggers
Outputs for AX-320C add-on exchanges to
support the maximum capacity of 104 doors
(3 AX-320C’s max.)
CO Line transfer output to Viking K-1900-5
programmable auto-dialer
Rack mountable
Programmable functionality via supplied software
Includes USB to serial adaptor and gender
changer, software program and Installation &
Operation Manual on CD, and QuikStart Guide
The unit can be surface mounted to a wall, desk
mounted, or mounted in a standard 19" EIA rack
using the supplied mounting brackets.
AX-084C Spec Sheet
0209 Pg. 1
Aiphone Corporation
1700 130th Ave NE * Bellevue, WA 98005
Ph: (800) 692-0200 * Fax: (425) 455-0071
tech@aiphone.com
AX-084C
Central Exchange Unit for AX Series
FEATURE CALL-OUTS:
[9]
[8]
[7]
[6]
[1]
POWER
DOOR RELEASE RELAY
L2 L3 L4 L5
L1
L6
L7
L8
VIDEO OUT
V2
V1
D1
D2
D3
D4
M1
M2
D7
D8
D5
D6
M3
M4
X1 OUT X2
AX-320C
AIPHONE AX-084C
[2]
FEATURE CALL-OUT DEFINITIONS:
[1] Power switch
[2] Door station ports
[3] Master station ports
[4] Add-on exchange unit port
[5] CO line port (Viking K-1900-5 auto dialer required)
[6] Setting/log port
[7] Video output ports
[8] Video output trigger ports
[9] Door release relay ports (L1 corresponds to door
station D1, L2 to door station D2, etc.)
[10] Power supply ports
[11] Power/Communications error display LE
[5]
[3]
[4]
[6]
[7]
AX-084C Spec Sheet
0209 Pg. 2
[1] AX-084C Exchange Unit
[2] Mounting screws
[3] Rack/Wall mounting brackets
[4] Installation CD, including setup software program and
instruction manual
[5] Mounting screws (for 19-inch
rack mounting)
[6] USB to serial programming
cable with driver
[7] QuikStart guide
+ - + D-PS V-PS
CO
[4]
[3]
[5]
[11]
[10]
SPECIFICATIONS:
Power Source:
24V DC, 2A. PS-2420UL (x2)
(1 for audio-only system,
2 for audio/video system)
Current
Consumption:
Video(Max) 0.62A, Audio(Max) 0.65A
Door
Release Contact: 24V AC/DC, 500mA
Mounting:
Desk, wall, or 19: EIA rack with
supplied brackets
Wiring:
RJ45 plugs for CAT-5e homerun wire
runs from each master and door/sub
2 Conductor wire from PS-2420UL to
power input terminals
CO Line Port:
RJ11 for Viking K-1900-5
programmable auto-dialer
Housing:
Metal
Color:
Black
Operating Temp:
32 – 104° F (0 ~ 40° C)
Dimensions:
(HxWxD)
3-7/16" x 1' 6-7/8" x 1' 1-3/16"
(88 x 480 x 335 mm)
Weight:
10.35 lbs (4,700g)
PACKAGE CONTENTS:
[1]
[2]
RS-232C
VCH1 VCH2
Aiphone Corporation
1700 130th Ave NE * Bellevue, WA 98005
Ph: (800) 692-0200 * Fax: (425) 455-0071
tech@aiphone.com
AL400ULPD4
Multi-Output Power Supply/Charger
1.4(A4)
Rev. DSAL400ULPD4_01172012
Overview
AL400ULPD4 is a multi-output power supply/charger which converts a
115VAC/60Hz input into four (4) Class 2 Rated 12VDC or 24VDC
power limited outputs.
AL400ULPD4
Input:
• Input 115VAC, 60Hz, 1.45 amp.
• Input fuse rated @ 3.5 amp/250V.
Specifications
Supervision:
• AC fail supervision (form “C” contacts).
• Low battery supervision (form “C” contacts).
• Battery presence supervision (form “C” contacts).
Output:
• 12VDC or 24VDC selectable output.
• 12VDC @ 4 amp or 24VDC @ 3 amp supply current.
• Four (4) Class 2 Rated fuse protected power
limited outputs.
• Outputs are rated @ 3.5 amp.
• Filtered and electronically regulated outputs.
• Short circuit and thermal overload protection.
Visual Indicators:
Battery Backup:
• Enclosure Dimensions (H x W x D approx.):
13.5” (342.9mm) x 13” (330.2mm) x 3.25” (82.55mm)
- Accommodates up to two (2)12VDC/7AH batteries.
• Product weight (approx.): 8.65 lbs. (3.86 kg.).
• Shipping weight (approx.): 9.55 lbs. (4.26 kg.).
• Built-in charger for sealed lead acid or
gel type batteries.
• Automatic switch over to stand-by battery
when AC fails.
• Maximum charge current 0.7 amp.
• AC input and DC output LED indicators.
Electrical:
• Operating temperature: 0º C to 49º C ambient.
• 18-27 BTU/Hr.
• System AC input VA requirement: 166.75VA.
Mechanical:
Agency Approvals
UL 294
UL 603
UL 1069
UL 1481
UL Listed for Access Control System Units.
UL Listed Standard for Power
Supplies for Use with Burglar-
Alarm Systems.
UL Listed Hospital Signaling and
Nurse Call Equipment.
UL Listed Standard for Safety for
Fire Protective Signaling Systems.
CUL Listed - CSA Standard C22.2
No.205-M1983, Signal Equipment.
Enclosure Dimensions (H x W x D) (approximate):
13.5” (342.9mm) x 13” (330.2mm) x 3.25” (82.55mm)
1.40”
(36mm)
4.85”
(123mm)
4.85”
(123mm)
1.40”
(36mm)
1.20”
(31mm)
3.25”
(83mm)
1.20”
(31mm)
0.75”
(19mm)
12.5”
(318mm)
11.0”
(279mm)
1.20”
(31mm)
0.75”
(19mm)
0.9375”
(24mm)
1.40”
(36mm)
1.40”
(36mm)
5.10”
(130mm)
5.10”
(130mm)
13.0”
(330mm)
5.10”
(130mm)
6.5625”
(167mm)
0.9375”
(24mm)
3.25”
(83mm)
3.25”
(83mm)
3.25”
(83mm)
1.0”
(25mm)
1.0”
(25mm)
1.0”
(25mm)
10.5”
(267mm)
Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com
1.0”
(25mm)
1.4(A5)
RY-24L
Form C Door Release Relay for AX, KB, KC, and JA Color Video Systems
- INSTRUCTIONS The RY-24L Door Release Relay Module is an interface between the door release contact on the Aiphone monitor and the
actual release mechanism. The contact closure directly out of the monitor is rated at 12V AC with a low current capacity. If
your strike or maglock requires more voltage or current, the RY-24L is required. It provides either a Normally Open contact
for an electric strike, or a Normally Closed contact for a magnetic lock. The contact rating supports a majority of door
release hardware available on the market. The RY-24L relay is recommended with all AX, KC, KB, and JA video systems
when using the door release feature. This will protect the built-in contact from possible surge damage.
(Note: For more than one door release on the KB system, use the RY-3DL.)
INSTALLATION:
1. Install in a suitable location, either near the power source for the door release mechanism, or behind the monitor.
2. Secure wire connections with proper termination, such as wire nuts or crimp connectors.
3. Trim the wires to the desired length.
JA-2MECD
4. Trim the unused contact wire so the bare strands are not exposed.
JA-2MCD
A1
A1
A2
A2
Door 2
A1
A1
JA-DAC
A2
A2
C1
C2
RY-24L
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
Brn
Door
Release
#1
Org
Yel
LOCK
POWER
C1
COM
N/O
N/C
RY-24L
Door
Release
#2
Blk
Red
Brn
MAGNETIC LOCK
WIRING METHOD:
Org
Blk
Red
C2
SUB
Door 1
JA-DAC
B1
B2
DOOR 2
RY-24L COLOR CODE:
Input of Relay:
Red:
L/ORG, Postive trigger
Black:
(-) NEGATIVE
Output of Relay:
Brown:
COMMON
Orange: N/O Contact
Yellow:
N/C Contact
(See contact rating specs on
back page)
ADAPTER
1
L/ORG
(-) Neg.
Common
N/O
N/C
ADAPTER
2
RED:
BLK:
BRN:
ORG:
YEL:
DOOR 1
WIRING DIAGRAMS:
JA System Wiring
#1
Purp
Blu
Grn
Yel
Org
Red
Brn
#2
PS-2420UL
+
-
+
-
L1 (Brn)
L1 (Red)
L2 (Org)
L2 (Yel)
Yel
(Normally Closed contact)
LOCK
POWER
Connect RED and
YELLOW wire on
JA--2MCD/-2MECD
directly to +
NOTE: The door release contacts are rated at 24V AC, 500mA. The RY-24L should be used in any application where the
strike or maglock has a higher voltage or draws more current. Otherwise, internal damage to the JA monitor could result.
Page 1
WIRING DIAGRAMS (cont):
Master
KB-3MRD
KB & KC System Wiring
KB-DAR
A1
1A1
B1
A2
1A2
B2
2A1
2A2
ELECTRIC STRIKE
WIRING METHOD:
3A1
PS-2420UL
3A2
(Normally Open contact)
+
-
Blk
Brn
Org
Red
CN11
Org
Yel
Yel
Connect
YELLOW
wire of CN11
directly to +
on unit.
LOCK
POWER
MAGNETIC LOCK
WIRING METHOD:
+
-
To (-) of
power supply
(Normally Closed contact)
Blk
LOCK
POWER
+
-
+
-
Red
Brn
Org
COM
Yel
N/C
Connect Red
to Orange
lead of Master
KC-1GRD
KC-1MRD
Use Brown & Yellow wires
when connecting to Maglock.
KC-DAR
A1
1A1
B1
A2
1A2
B2
+
-
PS-2420UL
+
-
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
Brn
Org
Yel
Blk
Red
COM
N/O
Yel
Org
S
S
Connect
YELLOW
wire of CN11
directly to +
on unit.
LOCK
POWER
NOTE: The door release contacts are rated at 12V AC, 400mA. The RY-24L should be used in any application where the
strike or maglock has a higher voltage or draws more current. Otherwise, internal damage to the KB/KC monitor could result.
Page 2
WIRING DIAGRAMS (cont):
AX System Wiring
LOCK
POWER
Blk
Red
Brn
Org
COM
N/O
Yel
Use Brown & Orange wires when
connecting to Electric Strike.
Blk
LOCK
POWER
COM
Yel
N/C
Red
Brn
Org
Use Brown & Yellow wires when
connecting to Maglock.
Connect separate RY-24L relay for each door release contact being used.
POWER
DOOR RELEASE RELAY
L1 L2 L3 L4 L5 L6 L7 L8
VIDEO OUT
V1
V2
D1
D2
D3
D4
D5
D6
D7
D8
M1
M2
M3
M4
X1 OUT X2
AX-320C
AIPHONE AX-084C
RS-232C
VCH1 VCH2
CO
+- +D-PS V-PS
+
AX-DV
AX-DV
Door #1
Door #2
AX-8MV
+
Master #1
PS2420UL
PS2420UL
SPECIFICATIONS:
NOTE: The door release contacts are rated at 24V AC/DC,
500mA. The RY-24L should be used in any application where
the strike or maglock has a higher voltage or draws more
current. Otherwise, internal damage to the AX Exchange Unit
could result.
Power Source:
Mounting:
Terminations:
Relay Input:
Relay Output:
N/O Output rating:
N/C Ouptut rating:
Wiring:
Supplied by master station or CEU
No mounting required
Color-coded prewired pigtails
24V DC, Red and Black wires, 22AWG
Brown, Red, Orange wires, 18AWG
5A at 30V DC or 125V AC
3A at 30V DC or 125V AC
2 conductors from unit’s door release contacts to RY-24L.
2 conductors from RY-24L to release mechanism, with power wired in series.
Dimensions (HxWxD): 1-3/4" x 7/8" x 7/16", with wires extending approx. 7-1/2"
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
Page 3
RY-24L Instr.
0210JD
1.4(A6.a)
1.4(A6.b)
Intrusion Systems | DS150i Series Request-to-exit Detectors
DS150i Series Request-to-exit Detectors
▶ Single or double door use
▶ Wall or ceiling mountable
▶ Internal vertical pointability
▶ Wrap-around coverage pattern
▶ Selectable relay trigger mode
▶ Selectable fail safe/fail secure modes
The DS150i Series consists of the DS150i Detector (light
gray) and the DS151i Detector (black). They are
specifically designed for Request-to-exit (REX)
applications. The DS150i and DS151i detect motion in
their coverage area and signal an access control system or
door control device.
Functions
Test Features
Externally visible activation LED.
Certifications and Approvals
Region
Certification
Europe
CE
2004/108/EC EMC Directive; 2006/95/
EC Low-Voltage Directive
USA
UL
ALVY: Access Control Systems Units
(UL294)
www.boschsecurity.com
2 | DS150i Series Request-to-exit Detectors
Installation/Configuration Notes
4.5 m
0 ft
0m
Technical Specifications
Electrical
4.5 m
0m
Current Draw:
26 mA at 12 VDC
Voltage:
12 VAC or VDC; 24 VAC or VDC
Mechanical
15 ft
15 ft
0 ft
4.5 m
15 ft
+14°
0m
4.5 m
15 ft
4.5 m
4.5 m
Alarm Output:
Two Form C relay contacts
Indicators:
One activation LED
Relay Latch Time:
Adjustable to 60 sec
Enclosure Dimensions:
3.8 cm x 15.9 cm x 3.8 cm
(1.5 in. x 6.25 in. x 1.5 in.)
Enclosure Material: High impact ABS plastic enclosure
Power Loss Default Programmable fail-safe or fail-secure modes.
Mode:
Timer Mode:
Programmable reset (accumulative) or non-reset
(counting) mode.
Mounting Location: Surface mount on wall or ceiling
0 ft
15 ft
0 ft
3m
0m
5 ft
Environmental
0m
15 ft
Operating Tempera- -29°C to +49°C (-20°F to +120°F)
ture:
3m
1.5 m
Radio Frequency In- No alarm or setup on critical frequencies in the
terference (RFI) Im- range from 26 MHz to 1000 MHz at 50 V/m.
munity:
-14°
0 ft
0m
0 ft
10 ft
10 ft
Ordering Information
Front View and Top Views
A front view of the DS150i and DS151i coverage, as well
as top views of the coverage pattern on the floor. The
typical coverage measurements are 2.4 m x 3 m
(8 ft x 10 ft).
0m
0 ft
-14°
1.5 m 0 m
+14°
4.5 m
0m
DS150i Request‑to‑exit PIR Detector
Gray enclosure. For use in request-to-exit
(REX) applications. Provides 2.4 m x 3 m
(8 ft x 10 ft) coverage.
DS150i
DS151i Request‑to‑exit PIR Detector
Black enclosure. For use in request-to-exit
(REX) applications. Provides 2.4 m x 3 m
(8 ft x 10 ft) coverage.
DS151i
Accessories
15 ft
0 ft
TP161 Trim Plate
A black trim plate used when mounting the
sensor over a standard single-gang box.
TP161
TP160 Trim Plate
A light gray trim plate used when mounting
the detector over a standard single-gang box.
TP160
4.5 m
15 ft
5 ft 0 ft
Side View
A side view of the DS150i and DS151i coverage pattern.
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
© Bosch Security Systems 2011 | Data subject to change without notice
T1138138123 | Cur: en-US, V20, 24 Aug 2011
Asia-Pacific:
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6258 5511
Fax: +65 6571 2698
apr.securitysystems@bosch.com
www.boschsecurity.asia
Represented by
1.4(A6.c)
MODEL TS-2T
SPECIFICATIONS
GREEN 2 INCH SQUARE PUSHBUTTON
LABELED “PUSH TO EXIT”
MOMENTARY ACTION SWITCH
S.P.D.T. TIMED CONTACTS RATED 2A.@35 VDC
TIME DELAY ADJUSTABLE FROM 2 TO 45 SECONDS
TIMER INPUT VOLTAGE 12 TO 24 VDC OR VAC
SWITCH ILLUMINATED WITH HI-BRIGHTNESS LED,
OPERATES ON 12 OR 24 VOLTS AC/DC
SWITCH MOUNTED ON SINGLE GANG S.S. PLATE
CONFORMS TO U.L. STANDARD 294 FOR ACCESS
CONTROL, U.L. FILE NUMBER SA32686
ALARM CONTROLS CORPORATION
19 BRANDYWINE DRIVE DEER PARK, NY 11729
1 631 586-4220 1 800 645-5538
WWW.ALARMCONTROLS.COM EMAIL INFO@ALARMCONTROLS.COM
INSTALLATION INSTRUCTIONS
MODELS TS-2T, TS-3T, TS-4T, TS-5T
U.L. FILE SA32686
RED LED 12/24 VOLTS DC
REAR VIEW OF PLATE
RED LED ONLY ON TS-3T, TS-5T
BLACK
RED
LED
TIMER INPUT VOLTAGE
12 TO 24 VOLTS AC OR DC
NON-POLARIZED
CURRENT DRAW: 60 MA.
MAXIMUM
RED
LED CURRENT RATING
9 MA. @ 12 VDC, 19 MA. @ 24 VDC
NEGATIVE ( BLACK ) LEAD
POSITIVE ( RED ) LEAD
GRAY
GRAY
GRAY LEADS
VIOLET
GREEN
BLUE
TIME ADJUSTMENT
BLACK
MAXIMUM TIME TURN POT
TOWARD PLATE
BROWN
MINIMUM TIME TURN POT
AWAY FROM PLATE
TIME RANGE: 2 TO 45
SECONDS
MOUNT WALLPLATE IN A
VERTICAL POSITION
TIMED OUTPUT CONTACTS
RATED 2 A, @ 35 VDC
VIOLET LEAD N/O CONTACT
GREEN LEAD COM CONTACT
BLUE LEAD
N/C CONTACT
INTERNAL LED
LED ( BLACK ) NEGATIVE LEAD
LED ( BROWN ) POSITIVE LEAD
LED CURRENT DRAW
4 MA. @ 12 VDC
15 MA. @ 24 VDC
LED OPERATES ON 12/24 VDC
MODELS TS-2T, TS-3T, TS-4T & TS-5T
SHOULD BE MOUNTED IN A 2.5 INCH
DEEP ELECTRICAL BOX
NOTE: TIMER WILL ACTIVATE WHEN PUSH TO EXIT SWITCH IS DEPRESSED.
SUBSEQUENT DEPRESSIONS OF THE SWITCH WILL RE-START THE TIMER.
ALARM CONTROLS CORPORATION
19 BRANDYWINE DRIVE P.O. BOX 280
DEER PARK, NY 11729
PH: 1 800 645-5538 1 631 586-4220 FAX ; 1 631 586-6500
WWW.ALARMCONTROLS.COM EMAIL: INFO@ALARMCONTROLS.COM
DOC. D-007 REV. B
4/09
TYPICAL WIRING DIAGRAMS
FOR MODEL TS-2T
NEG
POS
GREEN
BLUE
+V
BROWN
GRAY
G
R
A
Y
B
L
A
C
K
V
ELECTRIC DOOR STRIKE
FAIL SECURE MODE
NEG
POS
GREEN
VIOLET
BROWN
GRAY
+V
G
R
A
Y
B
L
A
C
K
V
AX-084C, 4 AX-8MV, 1 AX-DV
Composite Video Output
(1Vp-p, 75 Ohm)
Talk path / Channel 1
V+ to core
V- to braid
Release #1
Composite Video Output
(1Vp-p, 75 Ohm)
Talk path / Channel 2
V+ to core
V- to braid
PT
POWER
DOOR RELEASE RELAY
L1 L2 L3 L4 L5 L6 L7 L8
VIDEO OUT
V1
V2
D1
D2
D3
D4
D5
D6
M1
M2
D7
D8
M3
M4
X1 OUT X2
AX-320C
AIPHONE AX-084C
RS-232C
VCH1 VCH2
CO
+- +D-PS V-PS
+
+
AX-DV*
AX-8MV
AX-8MV
Door #1
Master #1
Master #3
PS-1
PS-1
Viking
K-1900-5
To Phone Line
(POTS)
AX-8MV
AX-8MV
Master #2
Master #4
NOTES:
1. Wire specification: CAT-5e for all AX sub stations, and masters.
2. AX-DV* shown can be replaced by any AX series sub station, or IE series door station.
3. Door stations with embedded card readers must have additional wire run from the card reader to
its own control panel.
4. Door release contacts can be programmed for either NO or NC operation.
5. Composite video output available on V1, V2 output of AX-084C.
6. See Product Installation Manual for complete system information and specifications.
Part Number for N. America
PS-1
PS-2420UL
PT
Determined by release
mechanism used
Wire Distance Specifications:
Components
Wire
AX-8MV to AX-084C
CAT-5e
Distance Notes:
980'
Each master is homerun to the exchange.
AX-Sub Station to AX-084C
980'
CAT-5e
Each substation is homerun to the
exchange. Sub stations include; AX-A,
AX-B, AX-DM, AX-DV, AX-DV-P, AX-DVF,
AX-DV-P, and IE series door stations.
Disclaimer: This diagram is provided as a service only, based on standard system configurations. Actual installation parameters may vary. Aiphone
Corporation does not warrant or assume any legal liability for this information, nor is Aiphone responsible for installation accuracy or costs incurred
involving on-site service.
QD #AX,8M,8SD
0307PH