RADWAG Laboratory balances - Price list

Table of contents ULTRA MICROBALANCE -­‐ UYA 3Y .............................................................................................................................................. 3 MICROBALANCE -­‐ MYA 3Y ........................................................................................................................................................ 4 MICROBALANCE FOR CALIBRATION OF PIPETTES -­‐ MYA 3Y.P .................................................................................................. 5 MICROBALANCES FOR FILTER WEIGHING -­‐ MYA 3Y.F .............................................................................................................. 6 ANALYTICAL BALANCES ʹ FILTER WEIGHING -­‐ XA 3Y.F ............................................................................................................. 7 ANALYTICAL BALANCES -­‐ PROFFESIONAL LINE -­‐ XA 3Y.A ......................................................................................................... 8 ANALYTICAL BALANCES -­‐ PROFFESIONAL LINE -­‐ XA 3Y ............................................................................................................. 9 ANALYTICAL BALANCES -­‐ PROFFESIONAL LINE -­‐ AS 3Y ........................................................................................................... 10 PRECISION BALANCES -­‐ PROFFESIONAL LINE -­‐ PS 3Y .............................................................................................................. 11 MOISTURE ANALYZER PROFFESIONAL LINE -­‐ PM 3Y .............................................................................................................. 12 PRECISION BALANCES -­‐ PROFFESIONAL LINE -­‐ WLY ............................................................................................................... 13 ANALITYCAL BALANCES -­‐ STANDARD LINE -­‐ XA/2X ................................................................................................................ 14 AUTOMATIC FEEDER -­‐ PA-­‐02/H .............................................................................................................................................. 15 WORKSTATION FOR PIPETTES CALIBRATION .......................................................................................................................... 16 LABORATORY HOLDERS .......................................................................................................................................................... 17 ANALITYCAL BALANCES ʹ STANDARD LINE -­‐ AS/X .................................................................................................................. 18 ANALITYCAL BALANCES ʹ BASIC LINE -­‐ AS/C2 ........................................................................................................................ 19 PRECISION BALANCES -­‐ BASIC LINE -­‐ PS/C2 ............................................................................................................................ 20 PRECISION BALANCES -­‐ BASIC LINE -­‐ PS/C1 ............................................................................................................................ 21 PRECISION BALANCES HEAVY DUTY LINE -­‐ APP/2C ................................................................................................................ 22 PRECISION BALANCES BASIC LINE -­‐ WLC ................................................................................................................................ 23 PRECISION BALANCES BASIC LINE -­‐ WTB ................................................................................................................................ 24 MOISTURE ANALYZER ʹ STANDARD LINE -­‐ PMX ..................................................................................................................... 25 MOISTURE ANALYZER ʹ BASIC LINE -­‐ PMC ............................................................................................................................. 26 ADDITIONAL EQUIPMENT FOR BALANCES.............................................................................................................................. 28 PC SOFWARE ........................................................................................................................................................................... 42 WEIGHTS AND MASS SETS (in wooden boxes; DKD or RADWAG calibration certificate) .................................................... 46 RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 2 ULTRA MICROBALANCE -­ UYA 3Y
Filling
Checkweighing
Percentage
Statistics
Formulation
GLP
procedures
Infrared
sensors
UYA series of ultra-microbalances has been designed to meet the highest requirements for
determination of mass. Measurement reliability and accuracy is ensured by system of automatic
internal calibration.
Microbalances consist of two major parts (an electronic system and a precise mechanical measuring
system in a separate casing). Such design eliminates the temperature influence and separates
mechanical components of a microbalance from shocks and vibrations caused by users operating
software. All the elements of a microbalance are made of glass and steel which eliminates the
influence of electrostatics on weighing process.
‡(OHFWURQLFOHYHOLQGLFDWRU
‡,QIUDUHGSUR[LPLW\VHQVRUV
‡Data exchange through USB
storage devices
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Basic technical parameters
Model
UYA 2.3Y
‡
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
2g
0,—J
—J
“—J
10-20 s
¡PP
22 500 USD
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 3 MICROBALANCE -­ MYA 3Y
Filling
Checkweighing
Percentage
Statistics
Formulation
Air buoyancy
correction
MYA series of microbalances has been designed to meet the highest requirements for determination of
mass. Measurement reliability and accuracy is ensured by system of automatic internal calibration.
GLP
procedures
Microbalances consist of two major parts (an electronic system and a precise mechanical measuring
system in a separate casing). Such design eliminates the temperature influence and separates
mechanical components of a microbalance from shocks and vibrations caused by users operating
software.All the elements of a microbalance are made of glass and steel which eliminates the influence
of electrostatics on weighing process.Basic technical parameters
‡(OHFWURQLFOHYHOLQGLFDWRU
‡,QIUDUHGSUR[LPLW\VHQVRUV
Model
Max
‡Data exchange through USB
storage devices
Infrared
sensors
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
MYA 2.3Y
‡
2g
—J
—J
“—J
5s
¡PP
10 000 USD
MYA 0,8/3.3Y
‡
3g
1/10 —J
—J
“—J
5s
¡/ ¡ 60 mm
10 000 USD
MYA 5.3Y
‡
5g
—J
1,6 —J
“5 —J
5s
¡26 mm
13 500 USD
MYA 11.3Y
‡
11 g
—J
2 —J
“6 —J
5s
¡26 mm
15 000 USD
MYA 21.3Y
‡
21 g
—J
2 —J
“7 —J
5s
¡26 mm
17 000 USD
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 4 MICROBALANCE FOR CALIBRATION OF PIPETTES -­ MYA 3Y.P
Filling
Checkweighing
Percentage
Statistics
Formulation
Air buoyancy
correction
GLP
procedures
MYA series of microbalances have been designed to meet the requirements of mass
measurements with the highest precision. Measurement reliability and accuracy is ensured by
internal calibration.
Infrared
sensors
Microbalances consist of two major parts (an electronic system and a high precision mechanical
measurement system in a separate casing). This solution eliminates temperature influence and
separates from shocks and vibrations caused by users operation. All the elements of the balance
are made of glass and steel which eliminates the influence of electrostatics on the weighing
process.Basic technical parameters
‡(OHFWURQLFOHYHOLQGLFDWRU
‡,QIUDUHGSUR[LPLW\VHQVRUV
Model
‡
MYA 21.3Y.P
‡Data exchange through USB
storage devices
Pipette calibration
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
21 g
—J
—J
“7 —J
5s
¡20 mm
18 500 USD
internal cal.
Prices and technical details are subject to change without prior notice.
A -­ evaporation ring B -­ calibration vessel
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 5 MICROBALANCES FOR FILTER WEIGHING -­ MYA 3Y.F
Filling
Checkweighing
Percentage
Statistics
Formulation
MYA series of microbalances series 2Y have been designed to meet the high requirements of mass
measurements with the highest precision. Measurement reliability and accuracy is ensured by
internal calibration.
GLP
procedures
Infrared
sensors
Microbalances consist of two major parts (an electronic system and a precise mechanical
measurement system in a separate casing). This solution eliminates the temperature influence and
separates from shocks and vibrations caused by users operating software. All the elements of the
balance are made of glass and steel which eliminates the influence of electrostatics on the weighing
process.
‡(OHFWURQLFOHYHOLQGLFDWRU
‡,QIUDUHGSUR[LPLW\VHQVRUV
Model
‡Data exchange through USB
storage devices
Air buoyancy
correction
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
MYA 5.3Y.F
‡
5g
—J
—J
“5 —J
5s
¡PP
13 500 USD
MYA 5.3Y.F1
‡
5g
—J
—J
“5 —J
5s
¡60 mm
14 500 USD
MYA 0,8/3.3Y
‡
3g
1/10 —J
—J
“—J
5s
¡/ ¡ 60 mm
10 000 USD
internal cal
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 6 ANALYTICAL BALANCES ² FILTER WEIGHING -­ XA 3Y.F
Filling
Checkweighing
Percentage
Statistics
Formulation
Counting pieces
GLP
procedures
Density
determination
Air buoyancy
correction
New electronics and technological solutions! Under hook
weighing
New intuitive operation and user friendly firmware of balances! Removable glass parts: side, top and back! Big size filter weighing! Balances XA/2X/F series are designed for weighing large filters. The balance features a spacious weighing chamber and a weighing pan dedicated for weighing filters with maximum dimensions of îPP As replacement to the pan for weighing filters, balance user can apply a standard weighing pan for regular weighing process. In the weighing chamber and over the weighing pan there is a large draft shield made of conducting glass for discharging static electricity. In addition, it functions as a anti draft protection. The weighing chamber comprises sliding side and top glass doors. XA/2X/F series features big backlit graphic display with extended menu, and 12-­keys membrane keyboard. Model
XA 52.3Y.F
‡
Max
Readability
Repeatability
Linearity
Stab
Stab filter
MSRP
52 g
0,01g
0,02 mg
“6 mg
5s
30 s
8 400 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 7 ANALYTICAL BALANCES -­ PROFFESIONAL LINE -­ XA 3Y.A
Filling
Checkweighing
Percentage
Statistics
Formulation
Counting pieces
GLP
procedures
Analytical balances XA.3Y.A type have been designed on the basis of new electronic modules and the
latest technology. Measurement reliability and accuracy is assured by internal calibration triggered by
time flow or temperature conditions. Balances are equipped with spacious weighing chamber with
automatically opened side glass doors.
Infrared
sensors
Density
determination
XA.3Y balances IHDWXUH´colour touch screen panel with new software for the highest convenience of
use!
‡(OHFWURQLFOHYHOLQGLFDWRU
‡,QIUDUHGSUR[LPLW\VHQVRUV
Model
XA 110.3Y.A
‡
‡
XA 210.3Y.A
‡Data exchange through USB
storage devices
Under hook
weighing
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
100 g
0,01 mg
0,02 mg
“PJ
5s
¡PP
5 070 USD
‡
‡
210 g
0,01 mg
0,02 mg
“PJ
5s
¡PP
8 700 USD
XA 82/220.3Y.A ‡
‡
82 g / 220 g
0,01 / 0,1 mg
0,02 / 0,08 mg
“ / 0,2 mg
5s/3s
¡PP
4 950 USD
XA 220.3Y.A
‡
‡
220 g
0,1 mg
0,08 mg
“PJ
3s
¡PP
4 650 USD
XA 310.3Y.A
‡
‡
310 g
0,1 mg
0,08 mg
“3 mg
3s
¡PP
5 750 USD
XA 510.3Y.A
‡
510 g
0,1 mg
0,08 mg
“3 mg
3s
¡PP
6 800 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 8 ANALYTICAL BALANCES -­ PROFFESIONAL LINE -­ XA 3Y
Filling
Checkweighing
Percentage
Statistics
Formulation
Counting pieces
GLP
procedures
Infrared
sensors
Analytical balances series XA 3Y have been designed on the basis of new electronic module and up-todate technology. Measurement reliability and accuracy is assured by internal calibration triggered by time
flow or temperature conditions.
Density
determination
Under hook
weighing
Balances are equipped with spacious weighing chamber with manually opened side and top glass doors.
Balances are operated by 5.´ FRORr touchscreen. 3Y series is the response to the growing market
demands concerning simple operation and maximum automation.
‡(OHFWURQLFOHYHOLQGLFDWRU
‡,QIUDUHGSUR[LPLW\VHQVRUV
Model
‡Data exchange through USB
storage devices
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
XA 110.3Y
‡
100 g
0,01 mg
0,025 mg
“PJ
5s
¡PP
4 100 USD
XA 210.3Y
‡
210 g
0,01 mg
0,025 mg
“PJ
5s
¡PP
8 000 USD
XA 82/220.3Y
‡
82 g / 220 g
0,01/ 0,1 mg
0,025/0,08 mg
“PJ
5 /3s
¡PP
3 800 USD
XA 220.3Y
‡
220 g
0,1 mg
0,08 mg
“PJ
3s
¡PP
3 600 USD
XA 310.3Y
‡
310 g
0,1 mg
0,08 mg
“3 mg
3s
¡PP
4 400 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 9 ANALYTICAL BALANCES -­ PROFFESIONAL LINE -­ AS 3Y
Filling
Checkweighing
Percentage
Statistics
Formulation
Counting pieces
GLP
procedures
Analytical balances of AS 3Y type has been designed on the basis of new electronic modules and
up-to-date technology.Measurement reliability and accuracy is assured by internal calibration
triggered by time flow or temperature conditions.
Infrared
sensors
Density
determination
Balances are operated by 5.´FRORr touchscreen. 3Y series is the response to the growing market
demands concerning simple operation and maximum automation.
Under hook
weighing
‡(OHFWURQLFOHYHOLQGLFDWRU
‡,QIUDUHGSUR[LPity sensors
Model
‡Data exchange through USB
storage devices
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
AS 220.3Y
‡
220 g
0,1 mg
0,1 mg
“PJ
2s
¡PP
2 760 USD
AS 310.3Y
‡
310 g
0,1 mg
0,1 mg
“3mg
2s
¡PP
3 000 USD
AS 510.3Y
‡
510 g
0,1 mg
0,3 mg
“4mg
2s
¡PP
4 600 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 10 PRECISION BALANCES -­ PROFFESIONAL LINE -­ PS 3Y
Filling
Checkweighing
Percentage
Statistics
Formulation
Air buoyancy
correction
GLP
procedures
Precise balances of PS 3Y are the response for the growing market demands concerning simple
operation and maximum automation of the weighing process.
Infrared
sensors
Measurement reliability and accuracy is assured by internal calibration triggered by time flow or
temperature conditions.
Density
determination
Balances are operated by 5.´ FRORr touchscreen. 3Y series is the response to the growing market
demands concerning simple operation and maximum automation.
‡(OHFWURQLFOHYHOLQGLFDWRU
‡,QIUDUHGSUR[LPLW\VHQVRUV
Model
‡Data exchange through USB
storage devices
Under hook
weighing
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Max
Readability
Repeatability
Linearity
Stab
Pan size
MSRP
0,001 g
“J
2s
îPP
2 057 USD
PS 250.3Y
‡
250 g
1 mg
PS 450.3Y
‡
450 g
1 mg
0,001 g
“J
2s
îPP
2 300 USD
PS 750.3Y
‡
750 g
1 mg
0,0015 g
“J
2s
îPP
2 550 USD
PS 1000.3Y
‡
1000 g
1 mg
0,0015 g
“J
2s
îPP
2 650 USD
PS 2500.3Y
‡
2500 g
10 mg
0,01 g
“J
1,5 s
îPP
2 270 USD
PS 4500.3Y
‡
4500 g
10 mg
0,01 g
“J
1,5 s
îPP
2 230 USD
PS 6000.3Y
‡
6000 g
10 mg
0,015 g
“J
1,5 s
îPP
2 650 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 11 MOISTURE ANALYZER PROFFESIONAL LINE -­ PM 3Y
Moisture
determination
Dry mass
determination
Drying profiles
Finish modes
Visualization of
drying process
Halogen or
infrared lamps
GLP
procedures
Permeability
of water vapour
Higher level
of temperature
Moisture analyzer is a laboratory measuring instrument intended to determine relative moisture content in samples of different
substances. PM 3Y features 5,7 /&' FRORXU WRXFK SDQHO ZKLFK SURYLGHV QHZ SRVVLELOLWLHV RI LQVWUXPHQW¶V RSHUDWLRQ DQG SUHVHQWLQJ
measurement results. It features extended databases containing programmable drying modes related to the database of samples. PM
3Y series enables printing and exporting charts presented on its display to a BMP file.
Highlights of moisture analyzer PM 3Y series:
- accuracy of moisture content readout 0,0001%
- heating components: halogen or IR emitter
- graphic presentation of drying result, charts: ǻm, %M, %D, %R,
- drying profiles: standard, mild, step, quick
- finish mode: AUTO 1 ± 5, manual, automatic, time defined
- database of drying procedures: ~1000 records for each data type
- database of samples
- interfaces: 2 x USB 2.0; 4IN / 4OUT; RS 232; Ethernet 10/100Mbit
3HUVRQDOL]DWLRQ RI LQVWUXPHQW¶V VHWWLQJV LV FDUULHG RXW LQ H[WHQGHG XVHU SURILOHV /HYHO FRQWURO LV EDVHG RQ /HYHO6(16,1* V\Vtem,
RADWAG patented solution, which uses a system of an electronic level. Standard and user defined printouts allow for maintaining
documentation complying with GLP/GMP requirements practically in any application.
Model
Max
d
Pan size
Accuracy of
moisture readout
MSRP
PM 60.3Y.WH
60 g
0,1 mg
¡PP
0,0001 %
4 500 USD
PM 200.3Y.WH
200 g
1 mg
¡PP
0,001 %
4 500 USD
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 12 PRECISION BALANCES -­ PROFFESIONAL LINE -­ WLY
Filling
Checkweighing
Percentage
Statistics
Formulation
Air buoyancy
correction
Labelling
Balances series WLY have been designed for fast and precise determination of mass in laboratory
and industrial conditions. They are the response to the growing market demands concerning simple
operation and maximum automation of the weighing process. WLY series is designed for cooperation
with bar code scanners, receipt printers, RFiD scanners and PC peripherals (mouse, keyboard, USB
memory sticks).
Infrared
sensors
Under hook
weighing
All models in WLY range are equipped with stainless steel weighing pan and ouch panel covering a
´FRORUWRXFKVFUHHQ. WLY series is prepared for connection of external weighing platform, This
option allows to create fully featured dual platform scale withresults displayed simultaneously on one
indicator. Additional features : programmable display and function keys.
Alibi memory
GLP
procedures
‡,QIUDUHGSUR[LPLW\VHQVRUV
‡Data exchange through USB
storage devices
‡Communication interfaces:
Ethernet, USB (2 ports), RS232
Model
Max
Readability
Repeatability
Linearity
Stab
Pan size
MSRP
WLY/2 2/D2
2 kg
0,01 g
0,03 g
“J
3s
îPP
1 310 USD
WLY/2 6/D2
6 kg
0,1 g
0,3 g
“0,3 g
3s
îPP
1 440 USD
WLY/2 10/D2
10 kg
0,1 g
0,3 g
“0,3 g
3s
îPP
1 570 USD
WLY/2 20/D2
20 kg
0,1 g
0,3 g
“0,3 g
3s
îPP
1 620 USD
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 13 ANALITYCAL BALANCES -­ STANDARD LINE -­ XA/2X
Filling
Checkweighing
Percentage
Statistics
Formulation
Counting pieces
GLP
procedures
Dismountable glass doors for easy cleaning
Density
determination
Air buoyancy
correction
XA/2X balances are equipped with big backlit graphic display with extended menu, 12-keys
membrane keyboard, big weighing chamber with sliding top and side glass door. Balance accuracy is
guaranteed by automatic internal calibration triggered by time flow or temperature changes. Balances
have possibility of disconnecting the head from weighing chamber. This solution considerably
reduces vibrations transferred to weighing chamber and decreases dimensions of device.
Under hook
weighing
XA/X balances enable to generate GLP procedures, these balances have RS 232 socket, PS/2,
possibility of connecting additional display and possibility of weighing loads outside the main
weighing platform (so called under-hook weighing).
Model
Max
Readability
Repeatability
Linearity
Stab
Pan size
MSRP
XA 110/2X
‡
‡
100 g
0,01 mg
0,025 mg
“PJ
5s
¡85 mm
2 440 USD
XA 82/220/2X
‡
‡
82 g / 220 g
0,01 / 0,1 mg
0,025/0,08 mg
“PJ
3s
¡PP
2 750 USD
XA 220/2X
‡
‡
220 g
0,1 mg
0,08 mg
“PJ
3s
¡PP
2 600 USD
XA 310/2X
‡
‡
310 g
0,1 mg
0,08 mg
“3 mg
3s
¡PP
2 750 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 14 AUTOMATIC FEEDER -­ PA-­02/H
Automatic feeder PA-­02/H Example of set (feeder PA-­02/H ;; balance AS220/3Y ;; printer)
CONSTRUCTION
Automatic feeder PA-02 is a device designed for automatic filling objects with small dimensions, in particular pills and capsules, as well
as small mechanical parts. The feeder, which is attached to a balance, provides even dosing of elements onto the weighing pan.
If joined with a RADWAG analytical balance series 3Y, it provides fast static control of samples according to strict pharmaceutical
requirements.
DESIGN AND FUNCTIONALITY
The device is based on a cylindrical vibrating container equipped with a conical or stepped storage bin offered in stainless steel version.
DXHWRDSSOLFDWLRQLQSKDUPDFHXWLFDOLQGXVWU\WKHIHHGHU¶VVWRUDJHELQLVFRQWLQXRXVO\ZHOGHGLQLWVLQQHUDQGRXWHUSDUWDQd it is
chemically electropolished. The feeder is appropriate for dosing pills from 3 to 15 mm in diameter, round and oblong, as well as details
with similar shapes and dimensions.
RADWAG laboratory balances series 3Y (AS/3Y and PS/3Y), which are cooperating with the automatic feeder, provide complete control
over the PA-02/H feeder. The balance controls the start and stop of the feeder and adjusts object feeding frequency. The device also
enables automatic feeding of objects according to pre-defined algorithm. Filled objects (e.g. pills) are weighed on a balance and
statistically assessed. The feeder fills the following object as soon as it receives an adequate command from the balance.
Model
Technical data
MSRP
PA-02/H
Diameter of filled object
Feeder diameter
+HLJKWRIIHHGHU¶VYLEUDWLQJHOHPHQW
Filling speed
Operating temperature
Power consumption
IP rating
Power supply
Control
Interface
‘·PP
‘PP
70 mm
·SFVPLQ
ƒ·ƒ&
8W
9 500 USD
IP 34
·9$&+]
External from balance level (AS/Y ; PS/Y)
RS 232
Net weight
16 kg
Dimension
îîPP
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 15 WORKSTATION FOR PIPETTES CALIBRATION
In order to ensure measurement reproducibility, and to meet all
the requirements resulting from supervision over measuring
equipment and to facilitate the process of pipettes calibration
RADWAG recommends effective and ergonomic solution of
calibrating automatic pipettes conducted by a user - complete
Workstation for Pipettes Calibration.
Purpose:
1. Calibration of automDWLFSLSHWWHVIURP—OWRPO
‡ZLWKIL[HGYROXPH
‡ZLWKDGMXVWDEOHYROXPH
2. Weighing of samples with maximum capacity up to 21g and
DFFXUDF\G —JLQVWDQGDUd weighing chamber - pan ¡PP
Unit contents:
1. Table for calibration with anti-vibration table
2. Analytical microbalance MYA 21.3Y.P
3. Environmental module:
‡Srobe for temperature, humidity and pressure measurement
‡Srobe for water temperature measurement
4. Used water kit:
‡Vink for used water (for right or left-handed)
‡container for used water
5. Computer set:
‡3&
‡VRIWZDUH3LSHWWHV5DGZDJpre-installed on PC)
‡/&'PRQLWRU
‡NH\ERDUGDQGPRXVH
6. Power supply
7. Armrests
Model
MSRP
Workstation for Pipettes Calibration
20 000 USD
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 16 LABORATORY HOLDERS
Email us at:
actionscale@aol.com
for Pricing
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 17 ANALITYCAL BALANCES ² STANDARD LINE -­ AS/X
Filling
Checkweighing
Percentage
Counting pieces
Density
determination
GLP
procedures
Dismountable glass doors for easy cleaning
Removable glass parts: side, top and back!
Balances series AS/X represent standard level of analytical balances. They feature backlit graphic
display. Measurement accuracy and reliability is assured by system of automatic
internaladjustment/calibration, triggered by time flow or temperature conditions.
Analytical balances series AS/X are offered with capacities 110, 160, 220 and 310 g with
readability of 0,1 mg.
Series AS/X is equipped with optional software for pipette calibration.
GLP procedure in AS/X series has a form of a easily modifiable content with selection of multiple
variables.
User has access to spacious weighing chamber with sliding top and side glass doors. AS/X series
is equipped with RS 232 socket, PS/2, additional display socket and possibility of weighing loads
outside the main weighing platform (under-hook weighing). Under-hook weighing is an alternative
for determiantion of mass with loads that have non-standard dimensions and shapes and those
which create magnetic field. Under hook weighing is also applied for density determination
procedures.
Model
Max
Readability
Repeatability
Linearity
Stab
Pan size
MSRP
AS 110/X
‡
‡
110 g
0,1 mg
0,1 mg
0,2 mg
3,5 s
¡PP
1 320 USD
AS 160/X
‡
‡
160 g
0,1 mg
0,1 mg
0,2 mg
3,5 s
¡PP
1 500 USD
AS 220/X
‡
‡
220 g
0,1 mg
0,1 mg
0,2 mg
3,5 s
¡PP
1 600 USD
AS 310/X
‡
‡
310 g
0,1 mg
0,1 mg
0,3 mg
3,5 s
¡PP
1 790 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 18 ANALITYCAL BALANCES ² BASIC LINE -­ AS/C2
Filling
Checkweighing
Percentage
Counting pieces
Density
determination
Under hook
weighing
Dismountable glass doors for easy cleaning
Removable glass parts: side, top and back! Balances series AS represent standard level of analytical balances. They feature backlit LCD
display. Accuracy and measurement reliability are assured by automatic internal
adjustment/calibration system, triggered by time flow or temperature conditions.
Analytical balances AS series are offered with capacities: 110, 160, 220 and 310 g. Redability of
AS series varies from 0,01/0,1 mg in model 60/220 g and 0,1 mg in case of other capacities.
GLP procedure in AS series has a form of a report from adjustment/calibration process, and its
content is non-modifiable.
User has access to spacoius weighing chamber with sliding top and side glass doors. Each
balance is equipped with RS 232 output and possibility of connecting an additional display as
standard.
AS balances have the option of weighing loads outside the main weighing platform (so called
under hook weighing). This means of mass measuring is an alternative for loads with non-standard
dimensions and shapes and those which create magnetic field. Under hook weighing is also
applied for density determination procedures.
Max
Readability
Repeatability
Linearity
Stab
Pan size
MSRP
AS 60/220/C2
Model
‡
‡
60 / 220 g
0,01/0,1 mg
0,03/0,1 mg
“PJ
6 s / 3,5 s
¡70 mm
1 405 USD
AS 220/C2
‡
‡
220 g
0,1 mg
0,1 mg
0,2 mg
3,5 s
¡mm
1 250 USD
AS 310/C2
‡
310 g
0,1 mg
0,1 mg
0,3 mg
3,5 s
¡PP
1 375 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 19 PRECISION BALANCES -­ BASIC LINE -­ PS/C2
Checkweighing
Percentage
Density
determination
Counting pieces
GLP
procedures
Under hook
weighing
Balances series PS are equipped with 12 key front panel and LCD backlit display. Pan dimension is
WKLVVHULHVLVîRUîPP%DODQFHVZLWKSDQVL]H[PPKDYHVSHFLDOJODVV
draught shield for protection againstr possible breeze. Each balance series PS C/2 have system of
automatic internal calibration, RS 232 and additional display outputs as standard.
GLP procedure is available in a form of a report from balance calibration. Shape of the printout is
modifiable. User name, project name, print of date and time, and print frame are user defined on
printout.
Balances are equipped with optional weighing of loads outside the weighing pan, so called under
hook weighing. it is an alternative for weighing loads with non standard dimensions or made of
magnetic substances. Under hook weighing is additionally applied in case of density determination
procedure.
Model
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
PS 210/C2
‡
‡
210 g
0.001 g
1 mg
“PJ
2s
128x128 mm
855 USD
PS 360/C2
‡
‡
360 g
0.001 g
1 mg
“PJ
2s
128x128 mm
880 USD
PS 1000/C2
‡
‡
1000 g
0.001 g
1 mg
“3 mg
2s
128x128 mm
950 USD
PS 1200/C2
‡
‡
1200 g
0.01 g
10 mg
“PJ
1,5 s
îPP
830 USD
PS 3500/C2
‡
‡
3500 g
0.01 g
10 mg
“PJ
1,5 s
îPP
855 USD
PS 4500/C2
‡
‡
4500 g
0.01 g
10 mg
“PJ
1,5 s
îPP
880 USD
PS 6000/C2
‡
‡
6000 g
0.01 g
10 mg
“30 mg
1,5 s
îPP
940 USD
internal cal.
EC approval
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 20 PRECISION BALANCES -­ BASIC LINE -­ PS/C1
Checkweighing
Percentage
Counting pieces
Density
determination
GLP
procedures
Under hook
weighing
Balances series PS are equipped with 12 key front panel and LCD backlit display. Pan dimension is
WKLVVHULHVLVîRUîPPZLWKDJODVVVKLHOGRYHUWKHZHLJKLQJSDQZKLFKSURWHFWV the
load against possible breeze. Each balance has RS 232 and additional display outputs as standard.
GLP procedure is available in a form of a report from balance calibration. shape of the printout is
modifiable. User name, project name, print of date and time, and print frame are user defined on
printout. Balances marked as C/1 are equipped with system of external calibration.
Balances are equipped with optional weighing of loads outside the weighing pan, so called under
hook weighing. it is an alternative for weighing loads with non standard dimensions or made of
magnetic substances. Under hook weighing is additionally applied in case of density determination
procedure.
Model
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
PS 210/C1
210 g
0.001 g
1 mg
“PJ
2s
128x128 mm
715 USD
PS 360/C1
360 g
0.001 g
1 mg
“PJ
2s
128x128 mm
740 USD
PS 510/C1
510 g
0.001 g
1 mg
“PJ
2s
128x128 mm
765 USD
PS 750/C1
750 g
0.001 g
1 mg
“3 mg
2s
128x128 mm
795 USD
PS 1000/C1
1000 g
0.001 g
1 mg
“3 mg
2s
128x128 mm
820 USD
PS 2100/C1
2100 g
0.01 g
10 mg
“PJ
1,5 s
îPP
720 USD
PS 3500/C1
3500 g
0.01 g
10 mg
“PJ
1,5 s
îPP
740 USD
PS 4500/C1
4500 g
0.01 g
10 mg
“PJ
1,5 s
îPP
770 USD
PS 6000/C1
6000 g
0.01 g
10 mg
“30 mg
1,5 s
îPP
795 USD
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 21 PRECISION BALANCES HEAVY DUTY LINE -­ APP/2C
Counting pieces
Checkweighing
Percentage
Under hook
weighing
Precision balances series APP are offered with weighing platform dimensions 36îPP%DODQFHV
are equipped with backlit LCD display.
APP series of balances is accdssible with following capacities: 25, 30, 35 and 6/35 kg ( ask for price )
Independently on version, APP balance is based on electromagnetic measuring system, external
calibration (C/2 - internal calibration) and RS 232 output. Balance casing is made of aluminum,
weighing pan is in stainless steel technology.
alances series APP have under hook weighing as standard solution. it is an alternative solution for
weighing masses with non-standard dimensions and those creating magnetic field. Under hook
weighing is also applied for densit determination process of solids.
Model
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
APP 25/2C
‡
25 kg
0,1 g
0,1 g
“J
3s
347î9 mm
1 970 USD
APP 30/2C
‡
30 kg
0,1 g
0,1 g
“3 g
3s
347î9 mm
2 310 USD
APP 35/2C
‡
35 kg
0.1 g
0,1 g
“3 g
3s
347î9 mm
2 910 USD
50 kg
0,1 g
0,15g
“5 g
3s
347î9 mm
4 500 USD
APP 50/C2/1
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 22 PRECISION BALANCES BASIC LINE -­ WLC
Counting pieces
Checkweighing
Percentage
Peak hold
Under hook
weighing
Animal weighing
Balances series WLC are designed for fast and precise mass determination in laboratory and
industrial conditions. They can also be used in areas with no access to mains (230V), as their
standard equipment includes internal rechargeable battery and RS 232 output.
:/&VHULHVLQGHSHQGHQWO\RQPRGHOSDQVL]HîîîîDQGî
mm) and capacity, is equipped with stainless steel weighing platform and backlit LCD display
providing good reading of weighing result.
Balances (A1 and A2) have possibility of weighing loads outside weighing platform (so called under
hook weighing), where the load is hanged under the instrument. This is an alternative for weighing
loads with non-standard dimensions and shapes.
Model
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
WLC 1/A2
1 kg
0,01g
0,03 g
“03 g
3s
îPP
400 USD
WLC 2/A2
2 kg
0,1 g
0,3 g
“0,3 g
3s
îPP
425 USD
WLC 6/A2
6 kg
0,1 g
0,2 g
“0,2 g
3s
îPP
440 USD
WLC 10/A2
10 kg
0,1 g
0,2 g
“0,2 g
3s
îPP
465 USD
WLC 20/A2
20 kg
0,1 g
0,2 g
“0,2 g
3s
îPP
485 USD
WLC 6/C1 K/R
6 kg
0,1 g
0,3 g
“0,3 g
3s
290x360 mm
665 USD
WLC 30/C1 K/R
30 kg
0,5 g
1,5 g
“1,5 g
3s
290x360 mm
710 USD
WLC 60/C2 K/R
60 kg
1g
1g
“1 g
4s
400x500 mm
755 USD
WLC 120/C2 K/R
120 kg
2g
6g
“6 g
4s
400x500 mm
805 USD
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 23 PRECISION BALANCES BASIC LINE -­ WTB
Counting pieces
Animal weighing
Checkweighing
Percentage
Summing
Peak hold
WTB balances are designed for fast and precise determination of mass in laboratory conditions.
WTB balances can be used in locations where no power (230V) is accessible as they are equipped
with internal rechargeable battery.
Balances are equipped with stainless steel weighin pan, RS 232 output and backlit LCD display.
Model
Max
Readability
Repeatability
Linearity
Stab.
Pan size
MSRP
WTB 200
200 g
0,001 g
0,003 g
“003 g
4s
¡PP
325 USD
WTB 2000
2000 g
0,01 g
0,03 g
“0,03 g
4s
îPP
245 USD
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 24 MOISTURE ANALYZER ² STANDARD LINE -­ PMX
Moisture
determination
Dry mass
determination
Drying profiles
Finish modes
Visualization of
drying process
Halogen or IR
GLP
procedures
Moisture analyzers are measuring instruments specially designed for determination of moisture
content in relatively small samples of various substances.
Permeability
of water vapour
Higher level
of temperature
as option
Moisture analyzer PMX is equipped with backlit graphic display, due to which the interface is clear
and easy to use. User menu includes data base with 99 drying procedures, with specified drying
parameters for easch entry (i.e. substance name, its number, ID, etc).
Moisture analyzer PMX enables:easy operation due to backlit graphic display; standard and nonstandard applications;available languages Polish, English, German, French, Spanish, Russian,
Czech;communication with usage of PC keyboard;data base with 99 drying procedures;drying
profiles (standard, mild, step, rapid);finish mode (manual, automatic, time defined);visualization of
drying process, GLP/GMP printouts and reports,halogen or infrared lamps
Maximal capacity of moisture analyzer series PMX is 50 g /0,1 mg (60 g/1 mg). Moisture content is
measured with accuracy 0,01%(0,001% for samples up to 1,5g). Maximal drying temperature equals
ƒ&DQH[WUDFRVWRSWLRQLVPRLVWXUHDQDO\]HUIRUGU\LQJZLWKWHPSHUDWXUHƒ&
Model
Max
Readability
Repeatability
Moist. Read.
Heating
Pan size
MSRP
PMX 50/1/NH
50 g
0,0001 g
+/-0,24%-0,04%
0,0001 %
Halogen
¡PP
1 550 USD
PMX 50
50 g
0,001 g
+/-0,24%-0,04%
0,001 %
Halogen
¡PP
1 430 USD
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 25 MOISTURE ANALYZER ² BASIC LINE -­ PMC
Moisture
determination
Dry mass
determination
Drying profiles
Finish modes
Halogen or IR
Higher level
of temperature
as option
GLP
procedures
Moisture analyzers are measuring instruments specially designed for determination of moisture
content in relatively small samples of various substances.
Moisture analyzer PMC enables:easy operation due to backlit LCD display,drying profiles (standard,
mild, step, rapid), finish mode (manual, humidity stabilization, automatic, time defined), GLP/GMP
printouts and reports, halogen or infrared lamps, standard and non-standard applications,
optimization of work due to halogen lamps mode
Maximal capacity of moisture analyzer series PMC ranges from 50 g /1 mg to 210 g/1 mg. Moisture
content is measured with accuracy 0,01% (0,001% for samples up to 1,5g). Maximal drying
WHPSHUDWXUHHTXDOVƒ&DQH[WUa cost option is moisture analyzer for drying with temperature
ƒ&(DFKPRLVWXUHDQDO\]HULVHTXLSSHGZLWKDOXPLQXPZHLJKLQJSDQZLWKGLPHQVLRQV¡PP
Model
Max
Readability
Repeatability
Moist. Read.
Heating
Pan size
MSRP
PMC 50/1/NH
50 g
0,0001 g
+/-0,24%-0,04%
0,0001 %
Halogen
¡PP
1 300 USD
PMC 50/NH
50 g
0,001 g
+/-0,24%-0,04%
0,001 %
Halogen
¡PP
1 200 USD
PMC 110/NH
110 g
0,001 g
+/-0,24%-0,04%
0,001 %
Halogen
¡PP
1 300 USD
PMC 210/NH
210 g
0,001 g
+/-0,24%-0,04%
0,001 %
Halogen
¡PP
1 500 USD
internal cal.
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 26 MOISTURE ANALYZER PROFFESIONAL LINE -­ PM 3Y
Moisture
determination
Dry mass
determination
Drying profiles
Finish modes
Visualization of
drying process
Halogen or
infrared lamps
GLP
procedures
Permeability
of water vapour
Higher level
of temperature
Moisture analyzer is a laboratory measuring instrument intended to determine relative moisture content in samples of different
substances. PM < IHDWXUHV /&' FRORXU WRXFK SDQHO ZKLFK SURYLGHV QHZ SRVVLELOLWLHV RI LQVWUXPHQW¶V RSHUDWLRQ DQG SUHVHQWLQJ
measurement results. It features extended databases containing programmable drying modes related to the database of samples. PM
3Y series enables printing and exporting charts presented on its display to a BMP file.
Highlights of moisture analyzer PM 3Y series:
- accuracy of moisture content readout 0,0001%
- heating components: halogen or IR emitter
- graphic presentation of drying result, charts: ǻm, %M, %D, %R,
- drying profiles: standard, mild, step, quick
- finish mode: AUTO 1 ± 5, manual, automatic, time defined
- database of drying procedures: ~1000 records for each data type
- database of samples
- interfaces: 2 x USB 2.0; 4IN / 4OUT; RS 232; Ethernet 10/100Mbit
3HUVRQDOL]DWLRQ RI LQVWUXPHQW¶V VHWWLQJV LV FDUULHG RXW LQ H[WHQGHG XVHU SURILOHV /HYHO FRQWURO LV EDVHG RQ /HYHO6(16,1* V\Vtem,
RADWAG patented solution, which uses a system of an electronic level. Standard and user defined printouts allow for maintaining
documentation complying with GLP/GMP requirements practically in any application.
Model
Max
d
Pan size
Accuracy of
moisture
readout
MSRP
PM 60.3Y.WH
60 g
0,1 mg
¡PP
0,0001 %
4 500 USD
PM 200.3Y.WH
200 g
1 mg
¡PP
0,001 %
4 500 USD
Prices and technical details are subject to change without prior notice.
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 27 ADDITIONAL EQUIPMENT FOR BALANCES
ANTI-­DRAFT SHIELD
Anti-­draft shield is intended for microbalances MYA series. It is an optional equipment of microbalances working in unfavourable conditions (air-­drafts and breezes). Compatible with: MYA series Email us at:
actionscale@aol.com
for Pricing
Model
ANTI-DRAFT SHIELD (for microbalances MYA) ANTI-­VIBRATION TABLE
Anti-­vibration table is designed to provide stable working conditions required for high precision weighing. The structure of the table ensures isolation from vibrations occuring during regular operation of a balance. Efficient table functioning is ensured by separating construction of the MDF laquered table from the actual antivibration part featuring a stone plate, which feaures threaded feet alowing height adjustment. 6L]HRIWKHWDEOH/î:î+îîPP 6L]HRIWKHVWRQHSODWH/î:î+îîPP Compatible with: MYA series;; XA;; AS series;; PS;; WLC;; WTB;; MAC;; MAX series Model
ANTI-VIBRATION TABLE ± Model SAL/M (mild steel construction)
ANTI-VIBRATION TABLE ± Model SAL/N (stainless steel construction)
Email us at:
actionscale@aol.com
for Pricing
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 28 PROFESSIONAL WEIGHING TABLE
The professional weighing table is made of two elements: a table with lockers, and an anti-­vibration table with stone top. The desk is made of MDF plate. It is equipped with two lockers and a sliding shelf for computer, mouse and keyboard installation. There is also place for uninterruptible power supply UPS or power strip. In the rear of the countertop there is a platform for placing a LCD display. The anti-­vibration table is made of mild steel. The stone top is a JUDQLWHSODWHZLWKGLPHQVLRQVîîPP Total dimensions of the professional weighing table with platform for /&'GLVSOD\DUHîîPP Compatible with: MYA series;; XA;; AS series;; PS;; WLC;; WTB;; MAC;; MAX series Model
Email us at:
actionscale@aol.com
for a Quote
PROFESSIONAL WEIGHING TABLE (mild steel construction)
LCD ADDITIONAL DISPLAY
Additional LCD display in plastic housing and a stand for placing on a table. Model WD-­3/01/Y compatible with: 3Y series;; Model WD-­3/01 compatible with: XA;; AS/X;; AS/C;; PS/X;; PS/C;; APP/C series;; Model WD-­4/01 compatible with: WLC;; WTB;; PUE/C31 Email us at:
actionscale@aol.com
for a Quote
Model
LCD ADDITIONAL DISPLAY (in plastic housing)
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 29 ANTI DRAFT CHAMBER
7KHVKLHOGLVGHVLJQHGIRUEDODQFHZLWKZHLJKLQJSDQîPP,W
is an optional equipment for balances operating in unfavourable conditions (breeze, wind). It is installed in place of standard pan protection. It is equipped with top and side sliding doors (free access to weighing pan). Compatible with: AS/PS/X;; PS/C (pan size 128x128mm). Model
Email us at:
actionscale@aol.com
for a Quote
ANTI DRAFT CHAMBER PS
ANTI DRAFT CHAMBER AS
ANTISTATIC IONIZER
Antistatic ionizer is used to remove overflow of plus ions mainly, minus ions from the load as well and elements of balance and environment. Electric charges of air are neutralized what give quasi-­
balance of plus and minus ions. Unbalance of plus and minus ions in the air can cause unwanted electric influences (attraction or repulsion) of elements which are in small distances to each other. It is usual for non-­conducting materials (plastic, glass). Some of the elements of balance are made of plastic and glass. This problem can affect the balances. Usually this problem appears as multiply repeatability error or as multiply error of indications. Model DJ-­03 compatible with: MYA series Model DJ-­02 compatible with: XA;; AS series. Model
ANTISTATIC IONIZER - Models: DJ-03 / DJ-02
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 30 DENSITY DETERMINATION KIT
Designed for analytical and laboratory balances featuring weighing SDQ ¡ DQG ¡ .,7 RU î128 mm (KIT 128). Manufactured in stainless steel. Applicable for determining density of: -­ solids (by measuring small samples placed on pans);; -­ liquids (with application of glass plunger with determined volume). Model KIT85 compatible with: XA;; AS series. Model KIT128 compatible with: PS series. Model
DENSITY DETERMINATION KIT - Models: KIT85 / KIT128
Email us at:
actionscale@aol.com
for a Quote
AMBIENT CONDITION MODULE ² MODEL THB
The system supports, up to 16 modular sensors, which allows for monitoring of ambient conditions in multiple points, within one or many rooms. The system supports, up to 16 modular sensors, which allows for monitoring of ambient conditions in multiple points, within one or many rooms. THB module is accessible for purchasing with the calibration certificate. Model
AMBIENT CONDITION MODULE ± Model THB: PC software & 1sensor in standard
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 31 AMBIENT CONDITION MODULE ² MODEL THB 2
THB2 module is a measuring instrument cooperating with the newest line of RADWAG automatic and manual mass comparators, and RADWAG laboratory balances series 3Y. The ambient conditions indications are recalled by pressing a FRUUHVSRQGLQJLFRQRQEDODQFH¶VWRXFKSDQHO7KHLQVWUXPHQWXVHUFDQ
preview ambient conditions using a touch panel of RADWAG weighing instrument. Based on sent measuring data, the software of balances series 3Y additionally determines air density, which value is also previewed on LQVWUXPHQW¶V WRXFK SDQHO The ambient conditions module is plugged to the mass comparator or 3Y series balance through RS 232 slot. It is easily detachable for calibration and adjustment purposes in user defined time intervals. THB2 module is accessible for purchasing with the calibration certificate. Compatible with: 3Y series. Model
Email us at:
actionscale@aol.com
for a Quote
AMBIENT CONDITION MODULE ± Model THB2: direct connection with 3Y series; 1sensor
Foot Button (for activate functions)
The foot button is designed for executing commands. It is a reliable tool aiding work of those operators who often utilize tarring / printing function. The length of cable connecting the buttons to a weighing instrument is 1,5 m. Compatible with: 3Y series: (multiple commands). XA/2X;; AS/X;; PS/X series: (TARE or PRINT commands). Model
Foot Button (for activate functions)
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 32 PC KEYBOARD
Model Ultra Slim
PC keyboard in Ultra Slim version (approx. 1/2 size of standard PC keyboards) with PS/2 or USB ports (3Y series balances). Facilitates fast and comfortable navigation through a balance menus. Compatible with: 3Y series Model
Email us at:
actionscale@aol.com
for a Quote
PC Keyboard ± model Ultra Slim
ADAPTER FOR PIPETTES CALIBRATION
Additional adapter for pipettes calibration is designed for gravimetric calibration and/or checking of piston pipettes. The content of the adapter: -­ base element;; -­ special weighing pan;; -­ measuring vessel;; -­ "evaporation curtain" vessel;; -­ glass cover with dosing hole. Compatible with: MYA 21.3Y microbalance model;; XA.3Y;; AS.3Y;; XA/2X;; AS/X series Model
ADAPTER FOR PIPETTES CALIBRATION
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 33 POWER ADAPTOR WITH BATTERY AND CHARGER
The power adapter ZR-­02 is designed for powering balances in areas with no access to mains. It features a built-­in charger. Compatible with: 3Y series -­ 5h balance operation time XA/X;; AS/X;; PS/X -­ 6h balance operation time AS/C;; PS/C;; APP/C -­ 8h balance operation time Model
POWER ADAPTOR WITH BATTERY AND CHARGER - Model ZR-02
Email us at:
actionscale@aol.com
for a Quote
DISPOSABLE PANS
Designed for moisture analyzers, available as a set of 50 pieces. Compatible with: MAX;; MAC moisture analyzers Model
DISPOSABLE PANS (Set of 50pcs)
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 34 SET FOR DETERMINATION OF WATER VAPOUR PERMEABILITY
Set is used for determination of water vapour permeability with various materials, like: clothes, knitted fabric, leather. Permeability of water vapour is a feature which directly determines quality and application possibility of specific material, like clothes, shoes, etc. If they are manufactured from improper materials, with incorrect permeability, they may be unhealthy and unpleasant in use. Using the set with application of moisture analyzer series MAC or MAX the testing procedure gets shortened from 72 hours to just 50 minutes. Compatible with: MA.3Y;; MAX moisture analyzer Model
SET FOR DETERMINATION OF WATER VAPOUR PERMEABILITY
Email us at:
actionscale@aol.com
for a Quote
INFRA RED EMMITER
IR emitter is used in moisture analyzers series MAC and MAX. It is DSSOLFDEOHLQPRLVWXUHDQDO\]HUVZLWKPD[WHPSHUDWXUHƒ&HOVLXV Compatible with: MA.3Y;; MAX;; MAC moisture analyzer Model
INFRA RED EMMITER
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 35 CONTROL THERMOMETER
Designed for moisture analyzers. It enables measurement of temperature with a probe installed on a cable. The control thermometer features fully waterproof casing and automatic switch-­off function, preventing from battery discharging. Powered from batteries: 3 x 1.5V (LR44). Compatible with: MAX;; MAC moisture analyzers Model
Email us at:
actionscale@aol.com
for a Quote
CONTROL THERMOMETER - Model GT105k-12
Calibration of thermometer GT 105k-12
CONTROL THERMOMETER SET FOR MA.3Y
Designed for moisture analyzers ± model MA.3Y It enables measurement of temperature with a probe installed on a cable. The control thermometer features fully waterproof casing and automatic switch-­off function, preventing from battery discharging. Powered from batteries: 3 x 1.5V (LR44). Compatible with: MA.3Y moisture analyzers Model
CONTROL THERMOMETER SET FOR MA.3Y
Calibration of thermometer GT 105k-12
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 36 AIR DENSITY DETERMINATION KIT
The set is dedicated for determining air density. It consists of two cylindrically shaped mass standards, and it is designed for use in microbalances MYA, analytical balances XA/3Y & XA/X with 0.01 [mg] accuracy.
Different types of balances use different models of air density determination kit: For MYA microbalances: -­ GLDPHWHUîPPPDGHRIVWDLQOHVVVWHHO -­ GLDPHWHUîPPPDGHRIDOXPLQLXP For XA.3Y & XA/2X balances: -­ GLDPHWHUîPPPDGHRIDOXPLQLXP -­ GLDPHWHUîPPPDGHRIVWDLQOHVVVWHHO Model
Email us at:
actionscale@aol.com
for a Quote
AIR DENSITY DETERMINATION KIT
ANTISTATIC CABLE
Cable for protective grounding of balances and scales. Facilitates removing electrostatic charges. Compatible with: All RADWAG balances and scales.
Model
ANTISTATIC CABLE - Model PA1
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 37 RS 232 CABLE (BALANCE -­ COMPUTER)
Compatible with: All RADWAG balances and scales.
Model
Email us at:
actionscale@aol.com
for a Quote
RS 232 CABLE (BALANCE - COMPUTER) - Model P0108 RS 232 CABLE (BALANCE ² KAFKA PRINTER)
Compatible with: All RADWAG balances and scales.
Model
RS 232 CABLE (BALANCE ± KAFKA PRINTER) - Model P0136 Email us at:
actionscale@aol.com
for a Quote
RS 232 CABLE (BALANCE ² EPSON OR CITIZEN PRINTER)
Compatible with: MYA;; XA/3Y;; AS/3Y;; PS/3Y;; APP/3Y.
Model
RS 232 CABLE (BALANCE ± EPSON or CITIZEN PRINTER) - Model P0151 Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 38 CAR LIGHTER 12V CABLE
Cable for plugging to car lighter 12V.
Compatible with: WLY;; PUE7 series. WLC;; WTB series.
Model
Email us at:
actionscale@aol.com
for a Quote
CAR LIGHTER 12V CABLE - Model K0047
WALL MOUNTING KIT
Wall mounting kit model PUE-­7-­32 is designed for easy mounting of the PUE 7 indicator on wall. The kit can be mounted in two ways, depending on expected angle of tilt of the indicator display. Compatible with: PS.3Y;; APP.3Y;; WLY;; PUE7.
Model
Email us at:
actionscale@aol.com
for a Quote
WALL MOUNTING KIT - Model PUE²7-32
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 39 TRANSPONDER CARD SCANNER
Transponder card scanner is used for quick identification and logging of operators to weighing system or identification of products from database. It cooperates with 3Y balances series and systems based on terminals series PUE7.
Compatible with: WLY;; PUE7. Model
Transponder card reader CK-01 (for PUE C41H; PUE5; PUE7)
Email us at:
actionscale@aol.com
for a Quote
BARCODE SCANNER
Barcode scanner model LS 2208, manufactured by Symbol, is a high quality, hand-­held scanner for laser scanning of bar codes. Its main features are very good ergonomics, small dimensions and light weight. Barcode scanner is applicable in weighing systems for: ‡4XLFNDVVRUWment choice in weighing systems;; ‡4XLFNRSHUDWRUFKRLFHLQZHLJKLQJV\VWHPV Compatible with: 3Y series;; WLY;; PUE7. Model
Email us at:
actionscale@aol.com
for a Quote
BARCODE SCANNER - Model SYMBOL LS2208
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 40 POWER LOOP OUTPUT
RADWAG power loop module 4-­20mA is designed for conversion of digital form of mass readout into analog one. Power output is a passive module, i.e. requires external power supply 24 VDC on power loop. The power loop module can reflect on its output mass indication as: direct value (no mark recognition) only positive values value with mark recognition ƒ
ƒ
ƒ
Compatible with: x
x
x
x
3Y series;; WLY;; PUE7. XA/2X;; AS/X;; PS/X. AS/C;; PS/C;; APP/C;; WLC;; WTB. Model
Email us at:
actionscale@aol.com
for a Quote
POWER LOOP OUTPUT - Model AP2-1 (plastic housing)
MODULE FOR CONNECTION ADD PLATFORM TO BALANCE
DP-­2 Module is designed to increase the functionality of an indicator model PUE 7. With application of the DP2 module, it is possible to connect additional platform to the existing scale. The DP-­2 module is installed inside the housing of indicator PUE 7. Compatible with: WLY;; PUE7. Model
MODULE FOR CONNECTION ADD PLATFORM TO BALANCE ± Model DP-2
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 41 PC SOFWARE
E2R MOISTURE PC SOFTWARE
E2R (Network Management Module) allows remote control over measurement process performed on multiple Radwag moisture analyzers (MAX series) connected through Ethernet.
The data is stored into MS SQL 2000 or 2005 computer database. Processed data enable generating graphs and reports of weighing processes. The software has practical application in laboratories and production plants using RADWAG moisture analyzers for systematic monitoring of production process. This is an indispensible tool in any facility where control, archiving and real-­time analysis of drying data is required. Model
E2R MOISTURE PC SOFTWARE (single workstation license)
E2R MOISTURE PC SOFTWARE (multiple workstation license)
Email us at:
actionscale@aol.com
for a Quote
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 42 PIPETTES PC SOFTWARE
Computer Software PIPETTES is designed for determination of volume measurement errors of pipettes (batchers) in accordance with the standard ISO 8655. The software supports calibration of fixed volume pipettes (single channel) and variable volume pipettes ( 1, 8, 12 channel).
The program contains both defined database of information on RADWAG pipettes and also enables defining your own models. Model
Email us at:
actionscale@aol.com
for a Quote
E2R PIPETTES PC SOFTWARE
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 43 BALANCE-WIN PC SOFTWARE
The program ensures cooperation of a weighing instrument and a computer: -­ Cooperation with one of two serial ports with selection of transmission parameters;; -­ Presentation of measuring data carried out in form of a column of numbers or a chart;; -­ Statistics from a series of weighing;; -­ Export data to other programs (Excel). Model
Email us at:
actionscale@aol.com
for a Quote
BALANCE-WIN PC SOFTWARE
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 44 RAD-KEY PC SOFTWARE
Cooperation between a weighing instrument and a computer: -­ Replacing a comma with a dot (useful when exporting data to Excel spreadsheet);; -­ Hot key (function keys from F1 to F12) triggering readout from the scale;; -­ Values are read as text or numeric. Model
Email us at:
actionscale@aol.com
for a Quote
RAD-KEY PC SOFTWARE
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 45 WEIGHTS AND MASS SETS (in wooden
boxes;; DKD or RADWAG calibration certificate)
Mass
Quantity
of pieces
1 mg - 500 mg
12
1 g - 100 g
9
1 g - 200 g
11
1 g - 500 g
12
1 g - 2 kg
15
1 kg - 5 kg
4
E1
E2
F1
F2
M1
Retail Price
Retail Price
Retail Price
Retail Price
Retail Price
1 730 USD
480 USD
225 USD
195 USD
195 USD
4 030 USD
745 USD
290 USD
260 USD
250 USD
4 730 USD
975 USD
350 USD
325 USD
310 USD
5 120 USD
1 600 USD
420 USD
390 USD
380 USD
8 100 USD
3 020 USD
740 USD
715 USD
680 USD
5 790 USD
2 420 USD
615 USD
520 USD
510 USD
Prices are subject to change without prior notice.
Sets of fraction standards and mass standards
Wire standards / knob shape
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 46 YOUR DEALER :
Action Scales
email: actionscale@aol.com
www.scalesct.com
Call for for a Quote
203-577-6420
RADWAG USA LLC Weighing was never so easy 19599 NE 10th AVE Unit E North Miami Beach, FL, 33179 Phone 1-­‐305-­‐651-­‐3522 / Fax 1-­‐305-­‐651-­‐3523 Strona 47