Technical Training Handbook and Reference Guide

Statement of Responsibilities
This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service
Representatives who are familiar with both the safety procedures, and equipment they service.
Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage
resulting from use of, improper use of, or failure to use the information contained in this document.
Cleveland Range, LLC has made every effort to provide accurate information in this document, but
cannot guarantee that this document does not contain unintentional errors and omissions.
The information in this document may be subject to technical and technological changes, revisions, or
updates.
Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or
updates.
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry
standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out /
tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas,
electric, and steam powered equipment and / or appliances
All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of
operation according to OSHA approved practices during any servicing of Cleveland Range equipment
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date
knowledge, skills, materials and equipment.
PowerPan™ SERIES
35" RIM HEIGHT
TILTING SKILLET, ELECTRIC
MODELS: SEL-30-T1
SEL-40-T1
ITEM NUMBER __________________________________________
Cleveland Standard Features
JOB NAME / NUMBER __________________________________
Available in 30 & 40 (115 & 150 liter) gallon open frame
design models. Full capacity to bottom of pouring lip.
■ High efficiency heating system with even heat distribution. 30
gallon models (115 liter) feature a 12 KW heating element
and the 40 gallon models (150 liter) feature a 18 KW heating
element.
■ Open base design for easy cleaning and maintenance.
■
■ 5/8" Stainless Steel Bead Blasted cooking surface prevents
warping and keeps food from sticking.
■ Durable 12 gauge, 304 Stainless Steel pan construction.
5
/8˝ (16mm) mild steel clad bottom plus a 1/16˝ (1.6mm)
Stainless Steel plate for even temperature distribution.
■ Low 35" rim height for easy operation and cleaning.
■ Splash Proof Controls and construction.
■ Easy-to-turn manual hand tilt. Optional power tilt with
manual override available.
■ Gallon/Liter Markings and Vented Spring Assist Cover
standard.
■ Available with Optional 2" Tangent Draw-Off Valve.
■ 10° Cooking Feature. Tilt unit up to 10° without the power
being turned off.
■ Adjustable, Electronic Thermostat accurately controls
temperature from 100° to 450° F.
Conforms to ASTM spec F1047-91.
Standard Voltages 208-240, single and three phase.
■ Spring-Assist Cover with full width handle and vent.
■
■
Shown with optional Double Pantry Faucet and Bracket
Options & Accessories
Short Form Specifications
❐ Power Tilt with Manual Override (PT1)
❐ 2" (50 mm) Tangent Draw-Off Valve (TD2)
❐ Double or Single Pantry Faucet (SPS, DPS)
❐ Faucet Bracket (FBKT1)
❐ Pan Carrier (PCS)
Shall be CLEVELAND, Tilting Skillet Model Number SEL-___-T1, electric
( _____ KW, _____ Volts ) holding no less than ( ____ gallons); Complete
with thermostatic and Safety Controls, Gallon/Liter Markings, 5/8"
Stainless Steel Clad Cooking Surface with Bead Blasted Finish, Easy to use
Manual Hand Tilt, Spring Assist Cover with adjustable Vent, Adjustable
Feet with Rear Flanged and Front Bullet Style, Gallon/Liter Markings and
Splash Proof Controls
❐ Vegetable Steamer Baskets (VS)
❐ Hot & Cold Water Pre-Rinse Spray Head with Hose
(PRS-S)
❐ Poaching Pans (PP)
❐ High Wattage Option (HW)
16KW on 30 gallons, 24KW on 40 gallons
Cleveland Range Inc.
Cleveland Range, LLC
Ph: 1-216-481-4900
Fx: 1-216-481-3782
SECT.
XII
9
PAGE
1201
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Ph:
1-216-481-4900
Fx:
1-216-481-3782
1333
East 179th St.,
Cleveland,
Ohio, U.S.A. 44110
Visit
our
Web
Site
at
www.clevelandrange.com
Visit our Web Site at www.clevelandrange.com
DIMENSIONS
MODEL
SEL-30-T1
SEL-40-T1
CAPACITIES
A
B
C
D
F
G
APPROXIMATE
SHIPPING WEIGHTS
In 4 oz. servings. Other sizes may be calculated.
30 gallons / 115 Liters.............960
40 gallons / 150 Liters...........1280
SEL-30-T1
39 1/8"
24 1/2"
31 3/4"
12"
18 1/4"
5 3/4"
(994mm)
(623mm)
(807mm)
(305mm)
(464mm)
(146mm)
51 1/8"
36 1/2"
43 3/4"
18"
24 1/4"
5 3/4"
(1299mm)
(928mm)
(1112mm)
(458mm)
(616mm)
(146mm)
410 LBS. (187 KG)
480V
RIGHT:
3" (77mm) (manual tilt)
0" (power tilt)
LEFT: 0",
REAR: 0"
390 LBS. (178 KG.)
SEL-40-T1
SPECIFICATIONS
CLEARANCE
ELECTRICAL SUPPLY
MODEL
208V
240V
AMPS
SEL-30-T1
SEL-40-T1
AMPS
AMPS
WATTAGE
KW
3ph
1ph
3ph
1ph
3ph
Standard
12
33.3
57.7
28.9
50
14.5
High
16
44.4
77
38.6
66.7
19.3
Standard
18
50
86.5
43.4
75
21.6
High
24
66.7
NA
57.8
NA
28.9
APPROVALS
UL
LEG LOCATION &
SUGGESTED FLOOR DRAIN DETAIL
CSA
5 1/4"
(134mm)
C
(FAUCET
OPEN)
3 7/8" (99mm)
30"
(762mm)
25 15/16"
(659mm)
A
B
(PAN SURFACE)
H C
FLOOR
DRAIN
GRATE
41"
1042mm
28 3/4"
731mm
12" x 20"
(305mm x
508mm)
(PAN
SURFACE)
4 7/8" (124mm)
120
D
5"
(127mm)
(MANUAL
TILT HANDLE)
120
7/16"Ø, 3 HOLES
ON 3 1/8" (80mm) B.C.D.
2" (51mm)
9/16" (15mm)
1" (26mm)
(MAXIMUM
ADJUSTMENT
FLANGED FOOT DETAIL
(REAR LEGS ONLY)
75
DPK
(OPTION)
71"
1804mm
9 1/2" (241mm)
(PAN DEPTH)
H C
39"
991mm
35"
889mm
(RIM
HEIGHT)
RECOMMENDED FLOOR
SLOPE 1" (26mm) IN 4' (1220mm)
4" (102mm) MINIMUM
6" (153mm) RECOMMENDED
FLOOR DRAIN
PIPE DRAIN RECOMMENDED
MINIMUM VALVE SIZE PLUS 1" (26mm)
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers.
Included among those approval agencies are U.L., NSF, CGA, CSA, ETL and others.
(NOT TO SCALE)
SECT.
XII
10
PAGE
1201
Litho in U.S.A.
CLEVELAND RANGE SEL T1
SEQUENCE OF OPERATIONS
When using these instructions refer to the SEL-T1 wiring schematic.
1. Supply Voltage is sent to the primary of the120 VAC transformer.
2. Supply voltage is sent to the normally open contacts of the Heat Contactors, C1
and C2.
3. 120 VAC is sent from the secondary of the 120VAC transformer through the 3
amp fuse to
• The primary of the 24 VAC transformer
o 24 VAC is sent from the secondary of the 24VAC transformer through
the 1.25 amp fuse to the on/off switch.
• Contacts of the R1 Heat Relay
4. 120 VAC is sent from the secondary of the 120 VAC transformer to the optional
Power Tilt Circuit (See step 9).
5. With the On/Off switch in the On position.
• 24 VAC is sent through the normally closed high limit switch to the mercury
switch..
• If the skillet is in the down position then 24 VAC is sent through mercury
switch to pin 9 on the thermostat.
6. If the skillet is calling for heat the 24 VAC is sent from pin number 10 to R1 Heat
Relay.
• The normally open contacts of the Heat relay close sending 120 VAC to the
Heat contactor coils C1and C2.
7. The Contactor close and supply Voltage is sent to the elements.
• The elements heat until the thermostat is satisfied.
8. When thermostat is satisfied, 24 VAC is removed from pin 10 on the thermostat and
the heat circuit is de-energized.
9. If the skillet has the optional Power Tilt option and is in the down position, 120 VAC
is sent from the secondary of the 120 VAC transformer through the circuit breaker
and the up limit switch to the tilt switch.
10. With the tilt switch in switch in the Up position
• 120 VAC is sent to the Bridge Rectifier
o 115 VDC is sent from the rectifier through the 30-ohm resistor to the
normally open RY10 and RY11 relay contacts.
• 120 VAC is sent to the RY10 relay coil.
• The normally open RY10 contact close and 90 VDC is sent to the DC motor
•
The DC motor is energized and the skillet tilts until the switch is released or the
up limit switch opens.
11. With the Tilt switch in the Down position
• 120 VAC is sent to the Bridge Rectifier
o 115 DC is sent from the rectifier through the 30-ohm resistor to the
normally open RY10 and RY11 relay contacts.
• 120 VAC is sent to the RY11 relay coil.
• The normally open RY11 contact close and the polarity of the 90 VDC is
reversed.
• The DC motor is energized and the skillet lowers until the switch is released or
the Down limit switch opens.
PROBLEM:
SEL-T1
Skillet won't
Heat
Skillet won't heat.
start
Supply power
to the skillet.
No
Is there supply
voltage to the
primary of the
power
transformer?
Yes
Replace the
power
tranformer
No
Is there 120 VAC
at the secondary
of the power
transformer?
Yes
Replace the 3
Amp fuse.
No
Is there 120 VAC
on the primary of
the 24 volt
transformer?
Yes
Replace the 24
volt transformer
No
Is there 24 VAC to
the secondary of
the 24 volt
transformer?
Replace the
contactor
Yes
Replace the
1.25 amp fuse.
No
No
Is there 24 VAC to
the ON/OFF
switch?
Is there supply
voltage to the
elements?
Yes
Replace the
ON/OFF
switch.
No
No
Is there 120 VAC
to the coil of the
No
heater contactors?
Is there 24 VAC to
the Mercury
switch?
yes
Is the skillet in the
down position?
No
Is there 24 VAC to
terminal 9 of the
thermostat board?
Replace heat
relay
Yes
Yes
Adjust or
replace the
mercury tilt
switch.
Replace the
open elements
Yes
Is there 24 VAC to
the High Limit
switch?
Yes
Replace the
High limit.
Yes
Yes
Is there 24 VAC to
the coil of the heat
relay with the
thermostat set
above the
temperature of the
pan?
No
Is the resistance of
the thermister probe:
1100 at 80 degrees
1350 at 200 degrees
1450 at 250 degrees
1550 at 300 degrees
1650 at 350 degrees
Yes
No
Lower the pan to
the down position
Replace the
thermostat
No
Replace
the
thermister
WIRING DIAGRAM
ELECTRICAL
COMPONENT
PART #s
FUSE 3A
KE52936-6
10
FUSE 1.25A
KE52936-8
10
RELAY 1
2475500
12
HEATING ELEMENTS -
SEE "PAN MOUNT ASSEMBLY" ON PAGE # 8
SENSOR
MERCURY
SWITCH
TILT SWITCH
RESISTOR
18
ON/OFF SWITCH
2474103
11
HIGH LIMIT
KE55069-7
8
THERMOSTAT
SE00119
SENSOR
SK50933-1
8
HEAT INDICATOR
SK50905-1
16
CIRCUIT BREAKER
KE50579-1
10
MERCURY SWITCH
KE50294-1
10
LIMIT SWITCH
KE51007
9
RY10 (RELAY)
KE50753-10
12
RY11 (RELAY)
KE50753-10
12
DC MOTOR
KE52832-4
11
11
BRIDGE RECTIFIER
KE50581
12
RESISTOR
SK50930
12
TILT SWITCH
- SECTION
- CONTACT BLOCK
KE53137-3
KE53184
KE53138-1
11
11
11