Agilent 8753ET/8753ES Network Analyzers

Agilent 8753ET/8753ES Network Analyzers
8753ET, 300 kHz to 3 or 6 GHz
8753ES, 30 kHz to 3 or 6 GHz
Configuration Guide
System configuration summary
The following summary lists the main components
required to form a basic measurement system.
In this configuration guide, the network analyzer
options for each model are listed first. General
product options that are available for both the
Agilent Technologies 8753ET and 8753ES are listed
next. Measurement accessories and peripherals
for both the 8753ET and 8753ES are also provided
in this configuration guide.
Transmission/reflection measurements
• Agilent 8753ET network analyzer
• Test-port return cable(s), 50 ohms
• Calibration kit for applicable connector type
Full S-parameter measurements
• Agilent 8753ES network analyzer
• Test-port return cables, 50 or 75 ohms
• Calibration kit for applicable connector type
System with user-selected test set
• Agilent 8753ES network analyzer
• Option 011 delete built-in test set
• S-parameter test set
• Test port return cables for selected test set
• Calibration kit for applicable connector type
Agilent 8753ET network analyzer
Agilent 8753ES network analyzer
A standard 8753ET covers 300 kHz to 3 GHz,
includes a built-in transmission/reflection test
set, and has two 50 ohm type-N female test ports.
Included with each instrument is a manual set
which includes an installation and quick start
guide, user’s guide, reference guide, programmer’s
guide, example programs CD-ROM, and a CD-ROM
containing the manual set. Instruments include
a 3-year return-to-Agilent service warranty.
A standard 8753ES covers 30 kHz to 3 GHz,
includes a built-in S-parameter test set, and has
two 7-mm test ports. Included with each instrument is a manual set which includes an installation and quick start guide, user’s guide, reference
guide, programmer’s guide, example programs
CD-ROM, and a CD-ROM containing the manual
set. Instruments include a 3-year return-toAgilent service warranty.
Network analyzer options
• Option 002
harmonic measurement capability
Provides measurements of swept second and
third harmonic responses. Option 006 extends
harmonic measurement capability to 6 GHz.
Network analyzer options
• Option 002
harmonic measurement capability
For measuring swept second and third harmonic
responses. Option 006 extends harmonic measurement capability to 6 GHz.
• Option 004
step attenuator
Extends source output power range from
–85 to +10 dBm.
• Option 006
6 GHz frequency extension
Provides source and receiver operation to 6
GHz. Do not order Option 006 with Option 075.
• Option 006
6 GHz frequency extension
Provides source and receiver operation to 6 GHz.
• Option 010
time-domain capability
For viewing reflection and transmission
responses in time or distance domain.
• Option 010
time-domain capability
For viewing reflection and transmission
responses in time or distance domain.
• Option 1D5
high-stability frequency reference
Provides improved frequency accuracy over time
and with temperature variation.
2
• Option 011
deletes built-in test set
Removes test set components and allows direct
access to the source output power and the R, A,
and B receiver inputs via type-N female connectors. Source start frequency is limited to 300
kHz for units that do not have Option 006. Do
not order Option 011 with Option 014 or 075.
• Option 014
configurable test set
Adds SMA connectors on front panel for access
to various source output and receiver input signal paths, including direct access to receivers.
When jumpers are in place, the analyzer performs like a standard 8753ES except that maximum source output power is reduced by 2 dB.
Do not order Option 014 with Option 011 or 075.
This option is not available as an upgrade kit, it
must be purchased at time of initial instrument
order.
• Option 075
75-ohm impedance
Replaces the standard 50 ohm test set with
a 75 ohm test set. Test ports are 75-ohm type-N
female connectors. Do not order Option 075
with Option 006, 011, or 014.
• Option 1D5
High-stability frequency reference
Provides improved frequency accuracy over time
and with temperature variation.
The following special options are available to customize the 8753ES for particular applications.
Please contact Agilent for a quote on these options,
to obtain information on expected instrument performance, or to request other special configurations.
• Option H16
low noise floor
Adds switches that allow the port 2 coupler
to be reversed, so that the forward transmitted
signal travels along the through path in the
coupler instead of the coupled path, increasing
the forward dynamic range by about 12 dB while
decreasing the dynamic range in the reverse
direction by about 15 dB.
• Option H39
three-port test set
Test set has an added coupler and switching
to provide three 50-ohm type-N female test
ports for measuring all nine S-parameters of
a three-port device.
• Option H68
6.8 GHz operation
Extends operation to 6.8 GHz. Performance
above 6 GHz is not specified (typical only).
• Option H85
high-power test set
Provides jumpers to allow the user to add an
external power amplifier to provide up to 20
watts (+43 dBm) of power at the test ports, and
high-power attenuators or isolators for higher
input power handling. The standard solid-state
transfer switch is replaced by a mechanical
transfer switch to handle higher output power,
and step attenuators are added between the
couplers and samplers to prevent receiver overload. Test ports are 3.5 mm, and the start
frequency of this test set is 50 MHz.
3
General product options
The following options are available for both the
Agilent 8753ET and 8753ES.
Rack mount options
• Option 1CM
rack mount kit without handles
• Option 1CP
rack mount kit with handles
Documentation options
• Option 0B0
deletes manual set
• Option 0B1
adds extra manual set
• Option 0BW
adds assembly-level service manual
This option provides a service manual for all
analyzers except an 8753ES with Option 011.
• Option 911
adds assembly-level service manual
For 8753ES Option 011.
The following language options provide
a translated user’s guide.
Option AB0 Traditional Chinese
(Taiwan) manual
Option AB1 Korean manual
Option AB2 Simplified Chinese
(PRC) manual
Option ABD German manual
Option ABF French manual
Option ABJ Japanese manual
Part number
5967-8513
5967-8514
5967-8512
5967-8516
5967-8517
5967-8511
Certification options
• Option UK6
Commercial calibration certificate with test data
Service and support options
• W01 converts three year return-to-Agilent
service warranty to a one year on-site service
warranty where available.
• W32 adds three years of return-to-Agilent
calibration.
• W34 adds three years of return-to-Agilent
standards-compliant calibration.
• W52 adds five years of return-to-Agilent
calibration.
• W54 adds five years of return-to-Agilent
standards-compliant calibration.
4
Measurement accessories
Accessories are available in these connector
types: 3.5 mm, 7 mm, 50-ohm type-N, 7-16, 75-ohm
type-N, and type-F. A standard 8753ES or one
equipped with Option 075 includes a built-in
S-parameter test set. A calibration kit and testport cables should be added for a complete measurement system. For an 8753ES Option 011 network analyzer, you also need to add a test set
or power splitter and bridge.
Test-port cables are used to connect to the device
under test. Calibration kits include standards,
such as open/short circuits and loads, which are
measured by the network analyzer for increased
measurement accuracy. Electronic calibration
(ECal) modules are used with the ECal interface
kit to provide automated calibration (in place of
a calibration kit). A verification kit is used in
conjunction with a calibration kit to verify system
performance.
50-ohm device measurements
Test-port cables
• 11857D
50-ohm 7-mm test-port return cables
A pair of phase-matched 610-mm (24 in) cables,
for use with the standard 8753ES network analyzer or the 85046A and 85047A test sets.
• Option B24
Deletes phase-match requirement.
• 11851B
50-ohm type-N RF cable set
For systems based on an 8753ES Option 011.
Includes three phase-matched 610-mm (24 in)
cables and one 860-mm (34 in) cable. Used with
Agilent 11850C and 11667A power splitters.
• Option B24
Deletes phase-match requirement.
Calibration kits
Choose a kit for each connector type to be used.
• 85031B
7-mm calibration kit
Contains fixed loads, and open/short circuit.
• 85032B
50-ohm type-N calibration kit
Contains fixed loads, open and short circuits,
and 7-mm to type-N adapters for both connector
sexes for use with 7-mm test-port cables.
• Option 001
deletes 7-mm to type-N adapters
These adapters are not needed when this kit
is used exclusively with an 8753ET system.
• 85033D
3.5-mm calibration kit
Contains fixed loads, one-piece open and short
circuits, and 7-mm to 3.5-mm adapters for both
connector sexes for use with 7-mm test-port
cables.
• Option 001
deletes 7-mm to 3.5-mm adapters
These adapters are not needed when this kit
is used exclusively with an 8753ET system.
• Option 002
replaces 7-mm to 3.5-mm adapters with type-N
to 3.5-mm adapters
This option is recommended when the calibration kit is used with the 8753ET.
• 85038A
7-16 calibration kit
Contains fixed loads, opens, and short circuits
in both connector sexes. Adapters not included
(see the “Adapters” section later in this guide
for information about the Agilent 11906 series
of 7-16 adapter kits).
• Agilent part number 8120-5639
50-ohm type-N male to type-N male test-port cable
For use with the 8753ET.
5
• 85038F
7-16 calibration kit (female standards)
Contains fixed load, open, and short circuit with
7-16 female connectors and a 7-16 (f) to 7-16 (f)
adapter. Other adapters not included; see the
“Adapters” section on the next page for information about the 11906 series of 7-16 adapter kits.
• 85038M
7-16 calibration kit (male standards)
Contains fixed load, open, and short circuit with
7-16 male connectors and a 7-16 (m) to 7-16 (m)
adapter. Other adapters not included; see the
“Adapters” section on the next page for information about the 11906 series of 7-16 adapter kits.
RF electronic calibration modules
This product family provides electronic calibration
(ECal) capability. With ECal, the usual calibration
kit standards are replaced by one solid-state calibration module that can be programmed by the
analyzer’s internal firmware to present many different impedances to the test ports. A full two-port
calibration can be done with a single connection
in a few minutes, with reduced errors and wear
on connectors.
• 85097B
VNA interface kit and software
Contains interface module for connecting an
ECal module to an 8753E, 8753ET and 8753ES
analyzer.
6
• 85091C
7-mm RF ECal module
• 85092C
50-ohm type-N RF ECal module
• Option M0F
Module with type-N(m) and type-N(f)
connectors.
• Option 00F
Module with two type-N female connectors.
• Option 00M
Module with two type-N male connectors.
• Option 00A
Adds type-N(m) to type-N(m) adapter and
type-N(f) to type-N(f) adapter.
• 85093C
3.5-mm RF ECal module
• Option M0F
Module with 3.5-mm(m) and 3.5-mm(f)
connectors.
• Option 00F
Module with two 3.5-mm female connectors.
• Option 00M
Module with two 3.5-mm male connectors.
• Option 00A
Adds 3.5-mm(f) to 3.5-mm(f) adapter and
3.5-mm(m) to 3.5-mm(m) adapter.
• 85098C
7-16 RF ECal module
• Option M0F
Module with 7-16(m) and 7-16(f) connectors.
• Option 00F
Module with two 7-16 female connectors.
• Option 00M
Module with two 7-16 male connectors.
• Option 00A
Adds 7-16(m) to 7-16(m) adapter and 7-16(f)
to 7-16(f) adapter.
Verification kit
• 85029B
7-mm verification kit
Includes attenuators and mismatch attenuator
with data on a 3.5-inch disk for use in confirming system measurement performance after a
calibration has been performed, traceable to
national standards. Test procedure is provided
in the service manual. For use with a standard
8753ES, or with systems including an 8753ES
Option 011 and an 85046A, or 85047A test set.
This verification kit may also be used with an
8753ET with the addition of two type-N(m) to
7-mm adapters. The 85031B 7-mm calibration kit
and 11857D test-port cables are also required.
Test sets (for use with 8753ES Option 011)
• 85046A
50-ohm S-parameter test set
300 kHz to 3 GHz. Requires the 11857D 7-mm
test-port return cables for two-port device
measurements. Includes a test set interconnect
cable and four RF cables to connect to the
8753ES Option 011.
• Option 913
Rack-mount kit, part number 5062-4069.
• 85047A
50-ohm S-parameter test set
300 kHz to 6 GHz. Requires the 11857D 7-mm
test-port return cables for two-port device
measurements. Includes a test set interconnect
cable and four RF cables to connect to the
8753ES Option 011.
• Option 913
Rack-mount kit, Agilent part number
5062-4069.
• 11850C
50-ohm type-N three-way power splitter
300 kHz to 3 GHz. Requires the Agilent 11851B
RF cable kit.
• 11667A
50-ohm type-N two-way power splitter
DC to 18 GHz. Requires the Agilent 11851B
RF cable kit.
• 86205A
50-ohm RF bridge 300 kHz to 6 GHz
• 86207A
75-ohm RF bridge 300 kHz to 3 GHz
Adapters
• 11525A
7-mm to 50-ohm type-N (male) adapter
• 11853A
50-ohm type-N accessory kit
Contains type-N(m) to type-N(m) adapters,
type-N(f) to type-N(f) adapters, and type-N male
and female shorts.
• 11854A
50-ohm BNC accessory kit
Contains type-N to BNC adapters for both
connector sexes and a BNC male short.
• 11906A
7-16 to 7-16 adapter kit
Contains one 7-16(m) to 7-16(m) adapter, one
7-16(f) to 7-16(f) adapter, and two 7-16(m) to
7-16(f) adapters.
• 11906B
7-16 to 50-ohm type-N adapter kit
Contains adapters for type-N(m) to 7-16(m),
type-N(m) to 7-16(f), type-N(f) to 7-16(m), and
type-N(f) to 7-16(f).
• 11906C
7-16 to 7-mm adapter kit
Contains two 7-mm to 7-16(m) adapters and two
7-mm to 7-16(f) adapters.
• 11906D
7-16 to 3.5-mm adapter kit
Contains adapters for 3.5-mm(m) to 7-16(m),
3.5-mm(m) to 7-16(f), 3.5-mm(f) to 7-16(m), and
3.5-mm(f) to 7-16(f) adapters.
7
75-ohm device measurements
Test-port cables
• 11857B
75-ohm type-N test-port cables
A pair of phase-matched 610 mm (24 in) cables,
for use with the 8753ES Option 075 or the
85046B S-parameter test set.
• Option B24
Deletes phase-match requirement.
• 11851B
50-ohm type-N RF cable kit
For systems based on an 8753ES Option 011.
Includes three phase-matched 610-mm (24 in)
cables and one 860-mm (34 in) cable. Used with
the 11850D power splitter.
• Option B24
Deletes phase-match requirement.
• 11857F
75-ohm type-F cables
Includes one 75-ohm type-N(m) to type-F(m)
cable, Agilent part number 8120-8396, and one
type-N(m) to type-F(f), part number 8120-8397.
Calibration kits
• 85036B
75-ohm type-N calibration kit
Contains 75-ohm fixed loads, open/short
circuits, and 50-ohm type-N to 75-ohm type-N
adapters in both sexes.
• 85039B
75-ohm type-F calibration kit
Includes 75-ohm male/female open, short, and
load standards and precision adapters N(f) to
F(m), N(m) to F(f), F(m) to F(m) and F(f) to F(f).
• Option 00M
male standards kit
Includes male open, short, and load standards
and precision F(m) to F(m) adapter.
• Option 00F
female standards kit
Includes female open, short, and load standards and precision F(f) to F(f) adapter.
8
RF electronic calibration modules
This product family provides electronic calibration
(ECal) capability. With ECal, the usual calibration
kit standards are replaced by one solid-state calibration module that can be programmed by the
analyzer’s internal firmware to present many different impedances to the test ports. A full two-port
calibration can be done with a single connection in
a few minutes, with reduced errors and wear on
connectors.
• 85097B
VNA interface kit and software
Contains interface module for connecting an
ECal module to an 8753E, 8753ET and 8753ES
analyzer.
• 85096C
75-ohm type-N RF ECal module
• Option M0F
Module with 75-ohm type-N(m) and type-N(f)
connectors.
• Option 00F
Module with two type-N female connectors.
• Option 00M
Module with two type-N male connectors.
• Option 00A
Adds type-N(m) to type-N(m) adapter and
type-N(f) to type-N(f) adapter.
• 85099C
75-ohm type-F RF ECal module
• Option M0F
Module with type-F(m) and type-F(f)
connectors.
• Option 00F
Module with two type-F female connectors.
• Option 00M
Module with two type-F male connectors.
• Option 00A
Adds type-F(m) to type-F(m) adapter and
type-F(f) to type-F(f) adapter.
Test sets (for use with 8753ES Option 011)
• 85046B
75-ohm S-parameter test set
300 kHz to 2 GHz. Requires the 11857B 75-ohm
test-port return cables. Includes a test set interconnect cable and four RF cables to connect to
the 8753ES Option 011.
• Option 913
Rack-mount kit, Agilent part number
5062-4069.
• 11850D
75-ohm type-N three-way power splitter
300 kHz to 2 GHz. Includes three 11852B 50to 75-ohm minimum loss pads for use with the
8753ES Option 011 (50 ohms). Requires the
11851B RF cable kit.
Minimum loss pads and adapters
• 11852B
50- to 75-ohm minimum loss pad (300 kHz to 3 GHz)
Adapts from 50-ohm type-N female to 75-ohm
type-N male. Nominal insertion loss is 5.7 dB.
• Option 004
Provides 50-ohm type-N male and 75-ohm
type-N female connectors.
• 11855A
75-ohm type-N accessory kit
Contains 75-ohm type-N male to type-N male
adapters, type-N female to type-N female
adapters, type-N male and female shorts, and
type-N male termination.
• 11856A
75-ohm BNC accessory kit
Contains 75-ohm type-N to 75-ohm BNC
adapters for both connector sexes, a BNC male
short and BNC male termination.
9
Test configuration accessories
RF limiter
Externally attaches to one or both test ports of
the analyzer. Provides protection against potential
high-power transients from external devices.
• 11930A
7-mm RF limiter, DC to 6 GHz,
max power +28 dBm typical
• 11930B
50-ohm type-N RF limiter, 5 MHz to 6 GHz,
max power +28 dBm typical
Probe
• 85024A
high-frequency probe
Provides high-impedance in-circuit test
capability, from 300 kHz to 3 GHz.
Amplifier
• 8347A RF
power amplifier
Used to set leveled output power or increase
system dynamic range, from 100 kHz to 3 GHz.
10
Power meters
For more accurate control of leveled test-port
power. Requires an 8480 series power sensor
and a GPIB cable for connection to the 8753ET
or 8753ES.
• E4418B
single-channel power meter
• E4419B
dual-channel power meter
Peripherals
The following peripherals may be used with the
Agilent 8753ET and 8753ES. Other peripherals
not listed here may also be compatible with these
instruments.
Keyboard
The keyboard with cable and adapter can be
connected to the Agilent 8753ET or 8753ES’s
DIN interface to form a remote front panel and
to provide a quicker, more convenient way to
enter titles, labels, and file names.
• Keyboard with mini-DIN cable
Interface Cables
Choose the appropriate cables to connect each
peripheral to the network analyzer.
• 10833A
GPIB cable, 1.0 m (3.3 ft)
• 10833B
GPIB cable, 2.0 m (6.6 ft)
• 10833D
GPIB cable, 0.5 m (1.6 ft)
Monitors
• Any VGA-compatible monitor
Printers
Measurement results can be printed from printers
with GPIB, parallel, or serial interfaces. For a list
of compatible printers, consult our printer compatibility guide Web page at www.agilent.com/find/pcg
11
Network analyzer upgrade kits
Upgrade kits for the Agilent 8753ET or 8753ES
Upgrade kits are available to add options to
an analyzer after initial purchase. To order an
upgrade kit for an 8753ET or 8753ES, order
the analyzer’s model number followed by a “U”
to indicate an upgrade kit, with one of the
following options.
• Option 002
harmonic measurement upgrade kit
The serial number of the 8753ET or 8753ES to
be retrofitted must be specified when ordering
this kit. Includes installation at an Agilent
service center.
• Option 004
step attenuator upgrade kit
Adds step attenuator to an 8753ET. Includes
installation at an Agilent service center.
• Option 006
6 GHz upgrade kit
Adds Option 006 to an 8753ET or an 8753ES
that does not have Option 011. Includes installation at an Agilent service center. The serial
number of the 8753ES to be retrofitted must be
specified when ordering this kit. Do not use
with an 8753ES that has Option 011 or Option
075.
• Option 611
6 GHz upgrade kit for 8753ES Option 011
Adds Option 006 to an 8753ES with Option 011.
Includes installation at an Agilent service center. The serial number of the 8753ES to be retrofitted must be specified when ordering this kit.
Do not use with an 8753ES that has Option 075.
• Option 010
time-domain upgrade kit
The serial number of the 8753ET or 8753ES to
be retrofitted must be specified when ordering
this kit. Installation is not included.
12
• Option 1D5
high-stability frequency reference retrofit kit
Includes installation at an Agilent service
center.
• Option 099 firmware upgrade
Provides the latest revision of firmware for the
8753ET or 8753ES. Firmware can be installed
by the user. The latest firmware is also available
for download from Agilent Technologies’ Web site.
Go to www.agilent.com/find/8753
Upgrade kits for the Agilent 8753E
• 8753EU Option 002
harmonic measurement upgrade kit
Includes installation at a local Agilent service
center. The serial number of the 8753E to be
retrofitted must be specified when ordering
this kit.
• 8753EU Option 006
6 GHz upgrade kit for 8753E
Adds Option 006 to an 8753E that does not
have Option 011. Includes installation at a local
Agilent service center. The serial number of the
8753E to be retrofitted must be specified when
ordering this kit. Do not use with an 8753E that
has Option 011 or Option 075.
• 8753EU Option 611
6 GHz upgrade kit for 8753E Option 011
Adds Option 006 to an 8753E with Option 011.
Includes installation at a local Agilent service
center. The serial number of the 8753E to be
retrofitted must be specified when ordering
this kit. Do not use with an 8753E that has
Option 075.
• 8753EU Option 010
time-domain upgrade kit
The serial number of the 8753E to be retrofitted
must be specified when ordering this kit.
Installation is not included.
• 8753EU Option 099
firmware upgrade kit
This upgrade provides the latest firmware revision
for the 8753E, which includes the new firmware
features introduced in the 8753ES. This firmware
is also available for download from Agilent’s Web
site. Go to www.agilent.com/find/8753
• 8753EU Option 1D5
high-stability frequency reference retrofit kit
Installation is not included.
Upgrade kits for the Agilent 8753D
• 8753DU Option 000
performance upgrade kit
Adds the new fast CPU board from the 8753E
and firmware to provide faster speed for
measurements, data transfers, and save/recall
of instrument states. Includes installation at an
Agilent service center. This upgrade does not
include four parameter display or ECal
firmware control capability.
• 11883A
harmonic measurement upgrade kit
Includes installation at a local Agilent service
center. The serial number of the 8753D to be
retrofitted must be specified when ordering
this kit.
• 11884B
6 GHz upgrade kit for 8753D
Adds Option 006 to an 8753D that does not
have Option 011. Includes installation at a local
Agilent service center. The serial number of the
8753D to be retrofitted must be specified when
ordering this kit. Do not use with an 8753D that
has Option 011 or Option 075.
• 11884C
6 GHz upgrade kit for 8753D Option 011
Adds Option 006 to an 8753D with Option 011.
Includes installation at a local Agilent service
center. The serial number of the 8753D to be
retrofitted must be specified when ordering
this kit. Do not use with an 8753D that has
Option 075.
• 85019B time-domain upgrade kit
The serial number of the 8753D to be retrofitted
must be specified when ordering this kit.
Installation is not included.
• Agilent part number 08753-60236
high-stability frequency reference retrofit kit
Installation is not included.
Upgrades for Agilent 8753B/C systems
• 86389A
solid-state switch upgrade kit for the 85046A/B
Includes installation at a local Agilent service
center. Requires 8753B/C with Rev. 3.0 or higher
firmware, or 8753E or 8753ES Option 011.
• 86389B
solid-state switch upgrade kit for the 85047A
Includes installation at a local Agilent service
center. Requires 8753B/C with Rev. 3.0 or higher
firmware, or 8753E or 8753ES Option 011.
• 11883A
harmonic measurement capability
Includes installation at a local Agilent service
center. The serial number of the 8753B/C to
be retrofitted must be specified when ordering
this kit. Requires external disk drive for
installation.
• 11884A
6 GHz frequency extension
Includes installation at a local Agilent service
center. The serial number of the 8753B/C to
be retrofitted must be specified when ordering
this kit.
• 85019B
time-domain capability (8753C/D only)
The serial number of the 8753C to be retrofitted
must be specified when ordering this kit.
Installation is not included.
13
Further information
8753ET and 8753ES overview
Pub. number
5968-5159E
8753ET and 8753ES data sheet
5968-5160E
For more information about the
Agilent 8753ET/ES, visit our Web site at
www.agilent.com/find/8753
Manuals
One manual set is included with each network
analyzer. Service manuals may be ordered as an
option. For on-line manuals, visit our Web site at
www.agilent.com/find/manuals
Part number
8753ET/ES manual set
08753-90470
For use with 8753ET and 8753ES
analyzers that do not have Option 011.
Includes the following:
• Installation and Quick Start Guide
08753-90471
• User’s Guide
08753-90472
• Reference Guide
08753-90473
• Programmer’s Guide
08753-90475
• CD-ROM, includes all documents 08753-90469
in the manual set
8753ES Option 011 manual set
Includes the following:
• Installation and Quick Start Guide
• User’s Guide
• Reference Guide
• Programmer’s Guide
• CD-ROM, includes all documents
in the manual set
08753-90477
08753-90478
08753-90479
08753-90480
08753-90475
08753-90469
8753ET/ES service guide
08753-90484
For use with 8753ET and 8753ES
analyzers that do not have Option 011.
Includes the service guide information
on a CD-ROM, Agilent part number
08753-90504.
8753ES Option 011 service guide
08753-90485
Includes the service guide information
on a CD-ROM, Agilent part number
08753-90504.
14
Related literature
Application note 1287-8
Simplified Filter Tuning Using
Time-Domain Analysis
5968-5328E
Application note 1287-9
In-Fixture Measurements Using
Vector Network Analyzers
5968-5329E
Pub. number
5965-7707E
5965-8166E
Application note 1287-2
Exploring the Architectures
of Network Analyzers
5965-7708E
Application note 1291-1
10 Hints for Making Better
Network Analyzer Measurements
5956-4352
Application note 1287-3
Applying Error Correction to
Network Analyzer Measurements
5965-7709E
Product note 8510-5A
Specifying Calibration Standards
for the 8510 Network Analyzer
5091-3645E
Application note 1287-4
Network Analyzer Measurements:
Filter and Amplifier Examples
5965-7710E
Product note 8510-8A
Applying TRL Cal to Non-Coaxial
Measurements
Application note 1287-5
Improving Throughput in
Network Analyzer Applications
5966-3317E
Product note 8720-2
5091-1943E
In-Fixture Microstrip Device Measurements
Using TRL* Calibration
Application and product notes
Most application and product notes
may be downloaded from our Web site at
www.agilent.com/find/tmappnotes
Application note 1287-1
Understanding the Fundamental
Principles of Vector Network Analysis
Application note 1287-6
5966-3319E
Using a Network Analyzer to
Characterize High-Power Components
Application note 1287-7
Improving Network Analyzer
Measurements of FrequencyTranslating Devices
5966-3318E
Product note 8753-1
Amplifier Measurements using the
8753 Network Analyzer
5956-4361
Product note 8753-2A
Mixer Measurements using the
8753 Network Analyzer
5952-2771
15
Agilent Technologies’ Test and
Measurement Support, Services, and
Assistance
Agilent Technologies aims to maximize the
value you receive, while minimizing your
risk and problems. We strive to ensure that
you get the test and measurement capabilities you paid for and obtain the support
you need. Our extensive support resources
and services can help you choose the right
Agilent products for your applications and
apply them successfully. Every instrument
and system we sell has a global warranty.
Support is available for at least five years
beyond the production life of the product.
Two concepts underlie Agilent's overall
support policy: "Our Promise" and "Your
Advantage."
Our Promise
Our Promise means your Agilent test and
measurement equipment will meet its
advertised performance and functionality.
When you are choosing new equipment,
we will help you with product information,
including realistic performance specifications and practical recommendations from
experienced test engineers. When you use
Agilent equipment, we can verify that it
works properly, help with product operation, and provide basic measurement
assistance for the use of specified capabilities, at no extra cost upon request. Many
self-help tools are available.
Your Advantage
Your Advantage means that Agilent offers
a wide range of additional expert test and
measurement services, which you can
purchase according to your unique technical and business needs. Solve problems
efficiently and gain a competitive edge
by contracting with us for calibration,extracost upgrades, out-of-warranty repairs, and
on-site education and training, as well as
design, system integration, project
management, and other professional
engineering services. Experienced Agilent
engineers and technicians worldwide can
help you maximize your productivity,
optimize the return on investment of your
Agilent instruments and systems, and
obtain dependable measurement accuracy
for the life of those products.
Windows® is a registered trademark of Microsoft Corporation.
By internet, phone, or fax, get assistance
with all your test and measurement
needs
Online assistance:
www.agilent.com/find/assist
Phone or Fax
United States:
(tel) 1 800 452 4844
Canada:
(tel) 1 877 894 4414
(fax) (905) 282 6495
China:
(tel) 800 810 0189
(fax) 1 0800 650 0121
Europe:
(tel) (31 20) 547 2323
(fax) (31 20) 547 2390
Japan:
(tel) (81) 426 56 7832
(fax) (81) 426 56 7840
Korea:
(tel) (82 2) 2004 5004
(fax) (82 2) 2004 5115
Latin America:
(tel) (305) 269 7500
(fax) (305) 269 7599
Taiwan:
(tel) 080 004 7866
(fax) (886 2) 2545 6723
Other Asia Pacific Countries:
(tel) (65) 375 8100
(fax) (65) 836 0252
Email: tm_asia@agilent.com
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2002
Printed in USA February 20, 2002
5968-5158E