allure® qs2 series range hood read and save these instructions

Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com
ALLURE® QS2 SERIES
RANGE HOOD
at
:: rangehoods . com
®
Page 1
ALLURE®
QS2 SERIES
RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
!
WARNING
CAUTION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range
hood with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
cooking flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. For best capture of cooking impurities, your range hood should
be mounted so that the top of the hood is 24-30” above the
cooking surface.
4. Please read specification label on product for further information and requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 5.
NOTE
If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
•
TABLE OF CONTENTS
This manual is divided into sections as follows:
• “PREPARE HOOD LOCATION”
Run ductwork from roof or wall cap, and electrical wiring from
service panel - to installation location
• “PREPARE THE HOOD”
Get your hood ready for installation
• “CONNECT WIRING”
Make electrical wiring connections to hood
• “INSTALL HOOD”
Secure hood to cabinet and ductwork - install bulbs and filters
• “OPERATION”
How to use the hood controls
• “CLEANING”
Keep your hood in top working condition
• “SERVICE PARTS”
Part numbers and exploded view of hood components
• “WARRANTY”
One-year limited warranty and how to contact us
Broan at :: rangehoods . com is a division of
kitchen :: accessories
U
N
L
I
M
I
T
E
D
Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com
ALLURE® QS2 SERIES
RANGE HOOD
at
:: rangehoods . com
®
Page 2
PREPARE HOOD LOCATION
PREPARE HOOD LOCATION
(Continued)
ROOF CAP
3¼" X 10"
(For vertical
discharge)
7” ROUND
VERTICAL DUCTING
SOFFIT
HOUSE WIRING
(Top or Back of hood)
CABINET
WALL CAP
HOOD
24" - 30" ABOVE
COOKING SURFACE
1
2
3¼" X 10" DUCT
(For horizontal discharge)
Determine whether hood will discharge vertically (3¼” x 10”
or 7” Round), or horizontally (3¼” x 10” only). For vertical or
horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minimum number of transitons and elbows.
Use diagrams, below, for proper placement of ductwork and
electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole.
3¼” X 10”
VERTICAL DUCTING
HOOD MOUNTING SCREWS (4)
1315/16" (30" hood)
1315/16" (30" hood)
1615/16" (36" hood)
1615/16" (36" hood)
1915/16" (42" hood)
1915/16" (42" hood)
CABINET FRONT
7½"
CABINET BOTTOM
5¼"
5¼"
1¼"
WOOD SHIMS
(recessed-bottom
cabinets only)
WOOD SHIMS
(recessed-bottom
cabinets only)
Run house wiring between service panel and hood location.
PREPARE THE HOOD
7” ROUND
DUCT PLATE
10½"
2"
VERTICAL DUCT
ACCESS HOLE
5"
3
1½"
CENTER
LINE
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
1
3¼” X 10”
HORIZONTAL DUCTING
CABINET FRONT
1/8"
Remove 7” Round Duct Plate from top of hood. Set duct
plate aside - with mounting screws.
FILTERS
¾"
DUCT
3¾" HORIZONTAL
ACCESS HOLE
CABINET
5¼"
5¼"
BOTTOM
7½"
1315/16" (30" hood)
1315/16" (30" hood)
1615/16" (36" hood)
1615/16" (36" hood)
1915/16" (42" hood)
1915/16" (42" hood)
HOOD
ELECTRICAL
MOUNTING
CENTER
ACCESS HOLE
SCREWS (4)
LINE
(in wall)
2
Remove tape holding Filters in place. Pull down on filter
tabs or finger holes and lift filters out. Set filters aside.
Broan at :: rangehoods . com is a division of
kitchen :: accessories
U
N
L
I
M
I
T
E
D
Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com
ALLURE® QS2 SERIES
RANGE HOOD
at
:: rangehoods . com
®
Page 3
PREPARE THE HOOD (Continued)
PREPARE THE HOOD (Continued)
NOTE
BOTTOM
COVER
(Held in
place with
2 screws)
If hood is to be installed Non-Ducted:
Purchase a set of (2) Non-Ducted Filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
• Skip to Step 9 on page 4.
•
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Vertical & for 7” Round
Discharge)
3
SEMI-CIRCULAR
DUCT KNOCKOUT
(Remove for 7” Round
Discharge)
Remove Bottom Cover from hood. Set cover and mounting
screws aside.
DAMPER/
DUCT
CONNECTOR
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Horizontal Discharge)
6
4
Remove appropriate Duct Knockout(s) from top or back of
hood.
Remove Damper/Duct Connector from inside the hood.
Set connector aside - with mounting screws and parts bag.
ELECTRICAL
CABLE CLAMP
5
Remove either top or back wiring knockout and install
approved Electrical Cable Clamp.
Broan at :: rangehoods . com is a division of
kitchen :: accessories
U
N
L
I
M
I
T
E
D
Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com
ALLURE® QS2 SERIES
RANGE HOOD
at
:: rangehoods . com
®
Page 4
PREPARE THE HOOD (Continued)
TAPE
WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock or tag service panel to prevent power
from being switched on accidentally.
TOP/BACK
EDGE
ç
è
UP TO 1”
SIDE-TO-SIDE
ADJUSTMENT
CONNECT WIRING
DAMPER/
DUCT
CONNECTOR
(Vertical
discharge
position shown)
PIVOT
7
3¼” x 10” Ducted Discharge Only: Remove Tape from damper
flap and attach Damper/Duct Connector over knockout
opening with screws removed in Step 4 under “PREPARE THE
HOOD”. Make sure damper Pivot is nearest to Top/Back Edge
of hood.
8
7” Round Ducted Discharge Only: Re-install 7” Round Duct
Plate removed in Step #1 under “PREPARE THE HOOD”.
Install a 7” round damper (purchase separately). Damper flap
must open freely in direction of airflow (away from range hood).
NOTE
HOUSE
WIRING
(120 VAC)
CARDBOARD
(Use to protect
cooktop)
1
Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard to protect the cooktop, if necessary.
Damper/Duct Connector and 7” Round Duct Plate can
be installed up to 1-inch on either side of hood center to accomodate off-center ductwork. In extreme off-center
installations, one end of the duct connector may need to
be trimmed to clear the electrical cable clamp.
RETAINING
RING
BLOWER
WHEEL
SECTIONS
TAB
GREEN
GROUND
SCREW
SMALL DIAMETER
END
RING
MOTOR STOP
SLOTS EDGE
9
Non-Ducted Installations Only: Require a Performance Ring
to be attached to the blower wheel.
To install ring:
1. Remove the Blower Wheel by rocking it side to side and
applying a slight force to pull wheel from motor. Remove
Retaining Ring if necessary.
2. Slide the ring onto the Small Diameter End of the wheel
and down to the Stop Edge of the wheel.
3. Reassemble wheel to motor. Make sure Tab on wheel fits
into one of the Motor Slots.
4. Push wheel down until it is locked in place.
5. Check that wheel is properly positioned as shown. Press
Sections into place if necessary. Make sure wheel turns
freely.
2
Connect house black to hood black wire, house white to hood
white wire, and house ground under Green Ground Screw.
Securely tighten cable clamp onto house wiring.
Broan at :: rangehoods . com is a division of
kitchen :: accessories
U
N
L
I
M
I
T
E
D
Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com
ALLURE® QS2 SERIES
RANGE HOOD
at
:: rangehoods . com
®
Page 5
INSTALL HOOD
OPERATION
Fan and Lights: 3 push button switches for each. Push any button
to select one of 3 fan speeds or one of 3 light levels. Push the
same button to turn fan or light off. Press another button to change
fan speed or light level. A light above each fan button indicates the
fan speed.
KEYHOLE (4)
MOUNTING SCREW (4)
1
Hang hood from (4) Mounting Screws. Slide hood towards
wall until mounting screws are engaged in narrow end of (4)
Keyholes. Tighten mounting screws securely. A long
screwdriver works best.
2
Replace bottom cover.
DUCT
TAPE
3
Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or R16,
40W MAX.
INCANDESCENT
BULB (2)
4
!
5
Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16,
40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
CAUTION: Bulbs may be hot! Refer to bulb packaging
for further information.
Replace filters, turn on power at service panel, and test for
proper operation.
Heat Sentry: Your range hood is equipped with the Heat Sentry
feature, which monitors temperature. The Heat Sentry will automatically turn the fan on at its highest speed when the temperature is above normal.
1) If a fan setting is selected when the Heat Sentry in on, the light
above the fan button will flash on and off.
2) If the fan setting is off when the Heat Sentry is on, the light above
fan button 3 will flash on and off rapidly.
After the temperature has lowered to normal, the fan will change
to the setting prior to the Heat Sentry turning on.
Fuse: The hood control contains a fuse to protect it from power
surges. If the fuse has opened (blown), the green fan-level indicators will operate properly when the fan buttons/switches are
pressed - but the fan and lights will not turn on.
The fuse is a 5 x 20 mm, 3 Amp, Fast-Acting, 125V (min.). Common
manufacturer and part numbers are: Littlefuse, 235003; Bussmann,
GMA3; Wickmann, 1911300002. Radio Shack, Digikey (1-800344-4539), and most electronic supply stores have them in stock.
To replace the fuse:
1. Disconnect power at service entrance.
2. Remove filters, bottom panel, light wire harness, and air chute.
3. Remove and inspect fuse. If it is not open (blown), additional
diagnostics need to be done.
4. Install new fuse.
5. Re-assemble air chute, light wire harness, bottom panel, and
filters.
6. Turn on power and check hood/control operation.
CLEANING
WARNING: To reduce the risk of electric shock, disconnect from power supply before cleaning.
Aluminum mesh filters: Clean frequently using hot water and a
mild detergent. Filters are dishwasher safe.
Charcoal filters: Clean filter surfaces frequently with a damp cloth
and a mild detergent. DO NOT immerse filters in water or put in
dishwasher. The special “Clean Sense” feature indicates when
the filter is to be replaced. The blue and yellow strips will blend to
green when it is time to change the filter. The “Clean Sense”
feature works best when facing toward the cooking surface.
To clean hood: Remove filters. Use a damp cloth and a mild detergent to wipe all grease-laden surfaces. Read the Silverstone ®
label on the bottom cover. It has instructions for care and cleaning
of the Silverstone® surface. Use care when cleaning blower wheel
- it must not become bent or misaligned. DO NOT ALLOW WATER
TO ENTER MOTOR. Make sure all surfaces are completely dry
before re-installing filters and restoring power.
Motor is permanently lubricated. Do not oil or disassemble motor.
Broan at :: rangehoods . com is a division of
kitchen :: accessories
U
N
L
I
M
I
T
E
D
Call 1-800-667-8721 anywhere in the US and Canada - www.rangehoods.com
ALLURE® QS2 SERIES
RANGE HOOD
at
:: rangehoods . com
®
SERVICE PARTS
Page 6
1
3
3
KEY NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
**
**
**
**
**
PART NO.
R680508
R740013
R602017
R334755
R501025
R627501
R627502
R627503
R627528
R169005
R169006
R169007
R169008
R601535
R602534
R602533
R680542
R680507
R111638
R401573
R602058
R601536
R651973
R169009
R520118
R531068
R607215
R111630
R7201621
R7201651
R7201671
R7201622
R7201652
R7201672
R7201624
R7201654
R7201674
R720163
R720166
R720168
R7201625
R7201655
R7201675
R169003
*
R169001
R680511
R680520
R680527
R501027
99010302
99010303
99010304
R680509
R607660
99010308
99010309
99010310
R111627
R564071
DESCRIPTION
7” Round Duct Plate (includes hardware)
Damper/Duct Connector (includes hardware)
Screw, #8-18 x ¼ Hex* (2 in package)
Motor Capacitor (includes wire nuts & hardware)
Isolation Transformer
Nameplate, White
Nameplate, Almond
Nameplate, Black
Nameplate, Biscuit
Control Panel, White (includes Key No. 6 & hardware)
Control Panel, Almond (includes Key No. 6 & hardware)
Control Panel, Black (includes Key No. 6 & hardware)
Control Panel, Biscuit (includes Key No. 6 & hardware)
Screw for Plastic, #6 x ½ Flat Hd. (3 in package)
Screw, #8-18 x 3/8 (2 in package)
Ground Screw
Scroll Cover, Outlet (includes hardware)
Scroll Cover, Front (includes hardware)
Control Assembly (includes Key Nos. 6, 7 & hardware)
Air Chute (includes hardware)
Screw for Plastic, #8 x ½ Pan Hd. (2 in package)
Screw, Metric M4 x 6mm (4 in package)
Motor Plate (Includes Key No. 18)
Motor Plate Mounting Kit (3 of each part)
Motor (includes Key No. 16)
Blower Wheel (Includes Key No. 21)
Retaining Ring
Lamp Socket Assembly
Light Panel, 30 in. White
Light Panel, 36 in. White
Light Panel, 42 in. White
Light Panel, 30 in. Almond
Light Panel, 36 in. Almond
Light Panel, 42 in. Almond
Light Panel, 30 in. Black
Light Panel, 36 in. Black
Light Panel, 42 in. Black
Light Panel, 30 in. Stainless
Light Panel, 36 in. Stainless
Light Panel, 42 in. Stainless
Light Panel, 30 in. Biscuit
Light Panel, 36 in. Biscuit
Light Panel, 42 in. Biscuit
Light Panel Mounting Kit
Pop Rivet, .125D (3 req.)
Filter Spring Kit (Includes 2 Pop Rivets) (3 req.)
Bottom Cover, 30 in. (includes Key Nos. 9, 25, & 26)
Bottom Cover, 36 in. (includes Key Nos. 9, 25, & 26)
Bottom Cover, 42 in. (includes Key Nos. 9, 25, & 26)
Autotransformer (includes hardware)
Aluminum Mesh Filter, 30 in. (2 in package)
Aluminum Mesh Filter, 36 in. (2 in package)
Aluminum Mesh Filter, 42 in. (2 in package)
Band, Non-Ducted
Hole Plug (1 req.)
Non-ducted Filter Kit, 30 in.
Non-ducted Filter Kit, 36 in.
Non-ducted Filter Kit, 42 in.
Wire Harness
Control Fuse, 3-Amp
Order replacement parts by PART NO. - not by KEY NO.
* Standard hardware - may be purchased locally.
** Not illustrated - purchase separately.
3
4
12
2
3
5
6
9
31
8
7
10
28
22
11
13
15
24
14
16
23
25
18
17
26
27
19
20
9
30
21
29
WARRANTY
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects
in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part
which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty
does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to
misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the express warranty.
Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply
to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S
SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
This warranty supersedes all prior warranties.
626892A
Broan at :: rangehoods . com is a division of
kitchen :: accessories
U
N
L
I
M
I
T
E
D