Axis 25733 Operating instructions

Product
Instructions
25733 & 25735
C O M M U N I C A T I O N S
Before attempting to connect or operate this product,
please read these instructions completely.
81-IN6210
03/28/07
IMPORTANT SAFEGUARDS
1. Read Instructions - All the safety and operating instructions
should be read before the unit is operated.
2. Retain Instructions - The safety and operating instructions
should be retained for future reference.
3. Heed Warnings - All warnings on the unit and in the operating
instructions should be adhered to.
4. Follow Instructions - All operating and user instructions should
be followed.
5. Electrical Connections - Only a qualified electrician should make
electrical connections.
6. Attachments - Do not use attachments not recommended by
the product manufacturer as they may cause hazards.
7. Cable Runs - All cable runs must be within permissible
distance.
8. Mounting - This unit must be properly and securely mounted to
a supporting structure capable of sustaining the weight of the
unit. Accordingly:
a. The installation should be made by a qualified installer.
b. The installation should be in compliance with local codes.
c. Care should be exercised to select suitable hardware to
install the unit, taking into account both the composition of
the mounting surface and the weight of the unit. Be sure to
periodically examine the unit and the supporting structure to
make sure that the integrity of the installation is intact. Failure
to comply with the foregoing could result in the unit separating
from the support structure and falling, with resultant damages
or injury to anyone or anything struck by the falling unit.
WARRANTY INFORMATION
Videolarm, Incorporated warrants that products sold hereunder
shall be fit for the ordinary purpose for which said products
are intended and shall be free from defects in material and
workmanship for a period of two years from date of sale to
buyer. Videolarm makes no other warranty of any kind with
respect to this product, whether expressed or implied, including,
without limitation, the implied warranty of fitness for a particular
purpose.
In the event of a breach of the above warranty, Videolarm shall,
at its option, repair or replace said product. This is Videolarm's
sole obligation under this warranty. In no event shall Videolarm
be liable for any incidental or consequential damages, as defined
in section 2-715 of the Uniform Commercial Code by a breach
of this warranty.
Videolarm shall repair or replace defective products upon shipment
of products prepaid to Videolarm, Inc., 2525 Park Central Blvd.,
Decatur, GA 30035.
SAFETY PRECAUTIONS
!
Caution
Risk of
Electric Shock!
CAUTION: TO REDUCE THE RISK OF
ELECTRICAL SHOCK, DO NOT EXPOSE
COMPONENTS TO WATER OR MOISTURE.
The lightning flash with an arrowhead symbol,
within an equilateral triangle, is intended to alert the
user to the presence of non-insulated "dangerous
voltage" within the product's enclosure that may
be of sufficient magnitude to constitute a risk of
electric shock to persons.
!
The exclamation point within an equilateral
triangle is intended to alert the user to presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the
appliance.
UNPACKING
Unpack carefully. Electronic components can be damaged if
improperly handled or dropped. If an item appears to have been
damaged in shipment, replace it properly in its carton and notify
the shipper.
Be sure to save:
1. The shipping carton and packaging material. They are the safest
material in which to make future shipments of the equipment.
2. These Installation and Operating Instructions.
SERVICE
If the unit ever needs repair service, the customer should contact
Videolarm (1-800-554-1124) for authorization to return and shipping
instructions.
TECHNICAL SUPPORT
If technical support is needed, Videolarm has set-up a 24 hour
technical support line for their customers.
24 HOUR TECHNICAL SUPPORT
Repairs made necessary by reason of accident, misuse or normal
wear shall be charged at Videolarm's standard rate. This warranty
gives you specific legal rights, and you may also have other rights
which vary from state to state.
1-800-554-1124
--
ELECTRICAL SPECIFICATIONS (OUTDOOR ONLY):
!
3, Open the dome assembly box. Note there is a protection
film on the dome. DO NOT REMOVE the film until the
product is fully assembled and installed. This film protects
the dome from scratches during installation. (Picture 3)
Power 24VAC, Class 2 Only
26 watts at 24 VAC (accessories)
Heater: 25 watts
Blower: 1 watt
NOTE: This unit is designed for operation in an
upright position. Installing the unit upside
down may cause damage to the internal
equipment, and will void the warranty.
GENERAL INSTRUCTIONS:
Tools Required: .100" Flat Head Screwdriver
Phillips Head Screwdriver
Picture 3
ASSEMBLING THE PRODUCT:
1. Remove the contents of the box onto a table. The larger
subassembly box is the housing assembly. The smaller
subassembly box is the dome assembly. (Picture 1)
4. There is a safety lanyard that is attached to the inside of
the dome assembly. Take the open end of the lanyard
and loop it around the lanyard tab that is located inside
the housing top. (Picture 4)
Picture 1
Picture 4
5. The safety lanyard is now attached to the housing.
2. Open the housing assembly box. Note there is a small roll
of Teflon Tape that will be needed during installation, put it
aside. (Picture 2)
Picture 2
Teflon Tape
--
Installing Axis 213 Camera
1. Install the camera onto the quick release bracket using (2)
10-32 x 3/8” screws and star washers provided in the packet.
½"
Attach cameras using these inserts
2. In the kit there are (8) aluminum spacers - (4) 1" and (4) ½".
Thread (2) spacers - (1) 1" and (1) ½" - on top of each of the (4)
2" spacers that are already located on the base bracket inside
the housing.
½" + 1"
spacers
1"
2"
3. Then start (3) 8-32x3/8” phillips head screws onto the 3½ inch
spacers inside the housing. Be sure to place the screws so that
they line up with the (3) open slots on the quick release bracket.
4. The camera assembly in the housing, sliding the (3) open
screw slots over the screws in the housing. Slide the bracket
forward, and the tighten the captive screw on the bracket
Captive Screw
(3) screws
in housing
--
Installing Axis 213 Camera (cont.)
CAMERA POWER
Connect the power plug and the ethernet cable to the back of the
camera.
For Model 21893 only
If alarm connections are needed use the chart below for reference.
CONTROL
RJ45 Ethernet Connector
ALARMS
1
Alarm 1
Blue
2
Alarm 2
Violet
3
Alarm 3
Gray
4
Common
White
Power Connection - Reference Only
+12 VDC
-12 VDC
--
Installing Axis 214 Camera
2685 Mounting Plate:
Attach camera using these (3) holes
2"
3. Place (3) 8 x 32 x s Phillips head screws on the top
of the spacer as shown above. Be sure to place the
screws so that they line up with the open slots on the
mounting plate.
4. Slide the mounting plate with camera into position on
top of spacers. Secure 3 screws and captive fastener.
1. Install the AXIS 214 camera to the 2685 mounting
plate using the (3) 3mm x 12mm bolt and lock washers
provided.
2. The AXIS 214 camera requires 2” of spacing for optimal
position within the housing. Use the 8 (1”) spacers
provided in the packet.
--
Installing Axis 231D/232D Camera
1. Install the camera onto the quick release bracket. Loosen one of
the screws on the bottom of the camera, see diagram below.
4. When the locking buttons hit the end of the keyhole slots.
Tighten the locking screw. Then put the camera assembly aside.
Locking screw
Loosen screw
2. Place quick release bracket onto the bottom of the camera,
making sure that the (3) locking buttons
line up with the keyhole slots
Keyhole slots
in the Q/R bracket.
Also make sure
Locking screw
the screw that
you loosened
up in the
previous
Captive insert
step lines
up with
the slot
located
next
to the
captive
Locking buttons
insert.
5. Remove the (4) ½” spacers that are attached to the base bracket
inside the housing.
½" spacers
½"
3. Turn the camera counter
clockwise.
Base Bracket
6. Now attach (4) ½” spacers (located in the packet that came with
the housing) to the base bracket.
½" spacers
Base Bracket
--
Installing Axis 231D/232D Camera
(cont.)
7. Then start (3) 8-32x3/8” plillips head screws onto the 3 inch
spacers inside the housing. Be sure to place the screws so that
they line up with the (3) open slots on the quick release bracket,
the screws on the bottom of the camera, see diagram below.
10.Locate the connector
block, which is
included with the
camera. Then
located the connector
block bracket, which
is included with the
housing. Attach the
block to the bracket
as shown in the
following diagram.
Use the M3 screws
and washers that are
located in the housing
packet.
(3) 8-32 x 3/8"screws
8. Since the 231D/232D camera operates on 24vac, the power
board that is located inside the housing is not needed. The
remove the power board, start by loosening the screws on the
terminal block and disconnect the orange and red wires.
9. With a Phillips head screwdriver remove the (4) machine screws
holding the power board to the base bracket.
Machine screws (4)
11.Attach the connector
block assembly to
the housing using (1)
6-32x3/8” screw and
star washer located in
the housing packet.
Base Bracket
--
Installing Axis 231D/232D Camera
(cont.)
13.To manage the input cable running from the connector block to
the camera use the (2) cable tie mounts and cable ties that are
located in the housing packet.
Cable Tie Mounts
12.Make wiring connections to connector block assembly per
camera instructions.
Cable Ties
For Model 25733 only
POWER
1
Camera Power (24VAC)
Red
2
Camera Power (24VAC)
Orange
CONTROL
RJ45 Ethernet Connector
ALARMS
1
Alarm 1
Blue
2
Alarm 2
Violet
3
Alarm 3
Gray
4
Common
White
--
Installing Axis 231D/232D Camera
(cont.)
14.Now grab the camera assembly and connector the RJ45 cable
and the input cable to the camera.
15.Now attached the camera assembly to the housing by sliding the
(3) open screw slots over the screws in the housing. Slide the
bracket forward, and the tighten the captive screw on the bracket.
Captive screw
Open screw slots
(REFERENCE ONLY)
- 10 -
Installing Axis 233 Camera
Keyhole Slots
1. Note the position of the mounting holes on the camera
bracket (see diagram below).
Mounting holes
4. Place the Quick Release plate onto the bottom of the
camera,
Mounting holes
2. Now attach (4) ½” spacers
(located in the packet
Make sure that the
locking screws
on the AXIS 233
camera line up
with the keyhole
slots on the Q/R
plate.
Slide the
camera into
the keyhole
slots by
targeting
the locking
screw(s).
that came with
the housing)
to the base
bracket.
½"
Keyhole Slots
Locking Screw
5. Turn the camera counter clockwise.
Keyhole Slots
Quick Release
(Q/R) plate
6. When the locking
buttons hit the end
of the keyhole
slots, tighten
the locking
screw.
3. Mount the
camera
bracket to
the Axis 233
camera
Q/R plate
(Quick
Release
plate) as
shown.
- 11 -
Chart A Wiring Color Code
Power and Control Inputs (Outside of housing)
POWER WIRING
Two plug-in wall transformers are included with the housing. Use
one to provide power for the heater and blower in the housing,
and the other for the camera. Determine where the transformers will be located, then run two sets of power wires into the wall
mount bracket (Four total power wires). Use the chart below to
determine the correct gauge of wire needed based on the length
of the run and the 30vA power line.
For Model 25735
See camera instructions for wiring connections
POWER
1
Camera Power (24 VAC)
Red
2
Camera Power (24 VAC)
Orange
3
Accessory Power (24 VAC)
Yellow
4
Accessory Power (24 VAC)
Green
24 VAC Wiring Distances
The following are the recommended maximum distances for 24VAC with a
10% voltage drop. (10% is generally the maximum allowable voltage drop
for AC-powered devices.)
Wire Gauge
Separate Power Supplies for Camera and Accessory Power
Camera:
25 watts (VA), 24 VAC, Class 2 Only
Accessory: 27 wattts (VA), 24 VAC, Class 2 Only
Total vA consumed
22
30
65
20
90
18
130
16
225
14
350
12
525
10
830
35
56
90
143
228
362
576
50
Maximum distance from transformer to housing
CONTROL
RJ45 Ethernet Connector
ALARMS
1
Alarm 1
Blue
2
Alarm 2
Violet
3
Alarm 3
Gray
4
Common
White
CONNECTING THE TRANSFORMERS
Determine which transformer will be attached to the camera. Attach
the red and orange wires to the terminal points on the transformer
For the transformer which will be used for the heater and blower, attach the yellow and green wires to the terminal points.
NOTE: You may attach wires to either terminal, however MAKE
SURE THAT THE TRANSFORMERS ARE ATTACHED TO THE
PROPER CONNECTION ON THE HOUSING.
The unit is setup with (2) individual power inputs.
1. Accessory Power (yellow and green wire)
2. Camera Power (red and orange)
Accessory
Power
If you wish to provide a single power transformer it is recommended that:
1. Be certain that you know the total power consumption of the
housing Heaters (25 watts) + Blowers (2 watts) + camera/pan-tilt
(not supplied)
213
=
24 watts @ 13Vdc
214
=
14 watts @ 12Vdc
231D/232D
=
25 watts @ 24Vdc
Green
Yellow
Accessory
Power
Camera
Power
Camera
Power
2. Check the supplied wiring chart to be sure that you have the
proper gauge wire for the distance that you intend to run your
power wires.
Orange
Red
3. Bring power to the 3 and 4 position of the power connector (yellow
and green wire)
4. Two jumpers are provided in the housing packet. Jumper from
the 1st position to the 3rd position and from the 2nd position to the
4th position of the terminal block. Be careful not to short between
the yellow and green wires.
Add 2 jumpers
for single
power input
One Power Supply for both Camera and Accessory Power
52 watts (VA), 24 VAC, Class 2 Only
NOTE: In this combination, run power to the camera connector, then
run jumper wires (not provided) to the accessory side of the
connector.
- 12 -
INSTALLING THE HOUSING ASSEMBLY:
!
REMOVING AND ATTACHING THE DOME ASSEMBLY:
Be sure the bracket is properly and securely
mounted to a supporting structure capable of rigidly
holding the weight of the entire unit.
1. Attach the dome assembly to the housing top by lining up
the arrow on the dome assembly with the left arrow on the
housing top. Insert the dome assembly into the housing and
then rotate the dome assembly clockwise until the dome
assembly’s arrow lines up with the arrow that has the word
locked above it. Then tighten the (3) screws on the front of
the dome assembly.
NOTE: This unit is designed for operation in an
upright position. Installing the product upside
down may cause damage to the internal
equipment, and will void the warranty.
1. This unit includes a 1½" NPT housing for a standard 1½"
NPT pipe. The housing can be used with other brackets
designed with 1½" male pipe threads, such as the 25736
wall mount brackets.
2. Attach the housing coupling (Figure 3).
NOTE: Pipe threads should be clean and rust free.
Use the Teflon™ tape included with
the housing on the threads.
Add thread
sealing tape
Figure 3
3. Mount the housing assembly to the mounting bracket
and housing coupling. A safety cable is included with
the housing to temporarily hold it while making wiring
connections. Loop the safety cable over one of the set
screws on the housing coupling and make the appropriate
connections using the (2) screw-down connectors supplied.
2. Remove the protective film from the dome.
2. Undo the safety cable and twist the housing onto the
housing coupling. Secure all (3) setscrews provided on the
housing coupling (Figure 4).
3. Clean the outside of the dome.
Set screws
Figure 4
- 13 -
Exploded View for Replacement Parts
15
14
9
8
7
6
4
5
3
2
1
- 14 -
Replacement Parts List
Part Number
Description
1
RPFD7501
LOWER TRIM RING (Long)
2
25740
TINTED REPLACEMENT CAPSULE
25741
CLEAR REPLACEMENT CAPSULE
3
RPFD703
DOME CLAMPING BRACKET
4
RPFD072
24 VAC HEATER
5
RPFD080
BLOWER
6
RPFD060
CAMERA BRACKET
7
RPRH707
CONNECTION PCB
8
RPFD040
HOUSING HARDWARE
9
RPFD709
HOUSING TOP
14
SD0160
PENDANT COUPLING KIT
15
SD0170
QUICK RELEASE PIPE COUPLING
N/S
RPNET02
24 TO 12VDC POWER BOARD
- 15 -