Mini-V Fog Machine Operating Instructions www.rosco.com

Add to my manuals
12 Pages

advertisement

Mini-V Fog Machine Operating Instructions www.rosco.com | Manualzz

Mini-V Fog Machine

Operating Instructions www.rosco.com

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Setting Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Fluid Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Remote Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Operating the Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Powering On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Using the Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Changing Fluid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Powering Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Ducting Fog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Exterior Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Storage and Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

CE Certificate of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

INTRODUCTION

Congratulations on your purchase of the Rosco Mini-V fog machine. Designed to meet the varied demands of projects including theatrical productions, feature films, photo shoots, industrial testing and safety training exercises – the Mini-V offers the perfect balance of performance, reliability and affordability. To ensure efficient and safe operation, please take a few moments to read this manual completely.

The Rosco Mini-V is a thermal aerosol generator designed for continuous fog output.

This machine is one part of a system, the other component being one of Rosco’s award winning fog fluids, including: Fog Fluid, Rosco Clear, Stage & Studio and Light Fog

Fluid. All Rosco fog and haze Fluids are unique water-based formulations that contain no petroleum distillates and are safe when used according to instructions. The operating temperature, pump pressure, and output nozzle of the Mini-V have been specifically designed and engineered together to maximize the aerosolization of Rosco fog fluids.

Do not use any fluids in the Mini-V other than genuine Rosco fog fluids as they have not been tested for optimal performance and safety considerations. Doing so may damage the machine and will void the warranty.

The Rosco Mini-V has been tested for use in professional theatrical productions and is included under the Equipment-Based Guidelines of the Equity-League Pension and

Health Trust Funds. The Mini-V is also compliant with the Alliance of Motion Picture and

Television Producers Safety Bulletin #10.

Note: The terms “fog,” “haze” and “smoke” are used interchangeably throughout this manual. Rosco Fog Equipment does not produce actual smoke, only a mist or aerosol.

- 1 -

IMPORTANT SAFEGUARDS

READ AND UNDERSTAND THESE SAFETY PRECAUTIONS BEFORE OPER-

ATING THE MACHINE. FAILURE TO PROPERLY FOLLOW THESE PRECAU-

TIONS MAY LEAD TO A FIRE, ELECTRICAL SHOCK, OR BURNS.

FOG FLUID HEALTH CAUTION: VAPOR FROM THIS FLUID, LIKE ANY

OTHER COMMON MATERIAL IN A VAPORIZED STATE, MAY BE IRRI-

TATING TO OR CAUSE ALLERGIC SYMPTOMS IN SOME PERSONS WITH

ALLERGENIC SENSITIVITY. DO NOT EXPOSE AT CLOSE RANGE TO

KNOWN ASTHMATICS.

The following symbols are used to identify important safety information:

Caution! Safety hazard. Risk of personal injury.

Caution! Safety hazard. Risk of personal injury.

Caution! Burn hazard. Hot surface.

Do not touch

Danger! Hazardous voltage. Contact will cause electric shock.

Caution! Fire hazard.

Preventing Electric Shock

• This machine uses electrical power at common commercially available

voltages. When directly contacted, such voltages are hazardous to human

life. All precautions commonly applicable to the use of electric power

generally are applicable to the use of this machine.

Caution! Burn hazard. Hot surface.

Do not touch

• This machine is designed to operate from three-wire power systems where

one of the wires is a safety ground. DO NOT disconnect the safety ground

or use extension cords or “cheater” plugs to connect this machine to a two-

wire system. Operation without a safety ground may result in a hazardous

Caution! Fire hazard.

Danger! Hazardous voltage. Contact will

electrical shock.

cause electric shock.

• Check the current and voltage rating of your machine. Extension cords

must be properly sized and rated for voltage, current and length. Check

your local electrical code for the correct gauge extension cord. If an exten-

sion cord shows signs of wear or gets warm to the touch, discontinue its

use and obtain a cord with a higher current rating. Improper extension

cords are not only hazardous, but may result in poor machine performance

due to excessive voltage drop.

• Never use any machine that shows signs of improper use. Even slight

damage may be an indication of a major problem. If the machine looks

questionable, use it only under strict observation. If the machine shows any

unusual behavior, disconnect machine immediately from power and send

machine to a Service Center for repair.

• Disconnect the machine from power source before servicing and when not

in use.

- 2 -

Caution! Safety hazard. Risk of personal injury.

Caution! Burn hazard. Hot surface.

Do not touch

Preventing Burns and Fire

Caution! Safety hazard. Risk of personal injury.

Danger! Hazardous voltage. Contact will cause electric shock.

• During the warm-up phase and during operations, people should not

stand within three feet (one meter) of the front of the machine. Flammable

material like paper, fabric, etc., should never be placed directly on or around

Caution! Burn hazard. Hot surface.

Do not touch

this equipment, or any other electrical device with a heating element.

Danger! Hazardous voltage. Contact will

Caution! Fire hazard.

• The fog should be blown into an open space and should not be directed

at people or objects. Never blow fog on hot surfaces, into glowing heating

elements or into open flames. The normally non-flammable and non-toxic

Caution! Fire hazard.

fog could react on very hot surfaces and be burnt or decomposed.

• Do not operate the machine in a tightly confined space where the ambient

temperature might exceed 135° F (57° C). A continuous flow of air is

electronic components deteriorate rapidly under high heat conditions.

Operation of the machine in an enclosure of less than ten cubic feet (one

cubic meter) is dangerous, and automatically voids the warranty.

• Enclosing any heating device so it is invisible to the operator creates

a potential fire hazard, no matter what the ambient temperature of

substantial risk. Rosco strongly recommends against it.

Safety Precautions

• In any facility, the fog concentration should be controlled. The fog should never

mask emergency exits, safety signs, staircases or other safety constructions.

Caution! Safety hazard. Risk of personal injury.

• After long use, or if the machine is not properly set, some liquid droplets or

wet area may appear in front of the machine’s outlet. This liquid should

be wiped up to prevent a condition where someone might slip and fall.

Do not touch cause electric shock.

Preventing Improper Operation

• Unauthorized repair or alteration of any safety devices can lead to

improper operation and accidents. Repairs should be performed only by an

authorized Service Center.

Caution! Safety hazard. Risk of personal injury.

• Use of any fluid other than Rosco fog fluids or modification or

attempted unauthorized repair of the machine will immediately

• Machines are designed for continuous use over an 8-hour day, but to protect

components, it is wise to turn off the machine when it is not in use. In

permanent installations, it is advisable to equip the circuit with a night

cut-off device.

Additional Precautions: Do’s & Don’ts

• Do Read the entire manual before operating the machine and pay particular

attention to all CAUTIONS AND WARNINGS.

• Do Use an extension cord that is properly rated for voltage, current and length, and

is free from nicks, cuts or other signs of wear.

• Do Check to see that the machine is clean and free of foreign objects before

each operating period.

- 3 -

• Do Insure that the machine is adequately ventilated.

• Do Use proper caution when handling hot surfaces.

• Do Use the minimum amount of fog required to achieve the desired effect.

• Do Not Use the machine near a person who has asthma or similar

inhalation disorder.

• Do Not Use any foreign substances in the machine.

• Do Not Use a machine that is damaged or operating improperly in any way.

• Do Not Use a machine that leaks fluid from the housing.

• Do Not Leave the machine switched on for prolonged periods without

producing fog.

• Do Not Enclose the machine.

• Do Not Install the machine in such a fashion that the operator can not see the whole

machine, including the indicator lights.

• Do Not Touch the shielded nozzle of the machine. Allow sufficient cooling time after

operation before attempting to perform maintenance or storage.

• Do Not Direct the fog output continuously against nearby surfaces. This may

eventually cause fluid to re-condense.

UNPACKING

Your Rosco Mini-V requires no assembly. Note: 230 volt machines are shipped with bare

leads at the end of the power cord. A proper electrical connector must be attached based

on the local power requirements. Carefully remove the machine from the box. Insure that no tape or packing materials are stuck to the machine. Stray packing materials that remain attached to high temperature areas of the machine could melt or burn during operation. In particular, insure that the area around the nozzle is free of any materials or debris.

CONTROLS

Main Power Switch

Turns the machine on or off by controlling the flow of power to the unit.

Fog Switch

The fog switch has three positions: an ON position that is designated as a single line, a MOMENTARY position that is designated as a double line, and the OFF position that is designated as “O” in the middle.

Press the switch in the desired direction to make fog.

Returning the switch to the center OFF position will stop fog production.

Ready Light

Fog Switch

Ready Indicator

A green indicator light located on the remote that illuminates when the minimum temperature for producing fog has been achieved.

- 4 -

SETTING UP

The Rosco Mini-V should be located on a secure, solid surface such as the floor. The machine can operate in any orientation from 45 degrees upwards to 45 degrees downwards. Take precautions to avoid fluid spills if the machine is oriented at an angle.

Fluid Set Up

Only use genuine Rosco fog fluids in your Mini-V machine. The use of any other fluid will

void your warranty, may damage the equipment, and may cause health hazards. For convenience, the Mini-V is designed with an integral compartment that will hold a

1-Litre bottle of fog fluid. Place the fluid bottle into the compartment. Feed the fluid inlet hose into the bottle of fog fluid, insuring that the filter, located at the end of the tube, is fully submerged in fluid. Slide the bottle cap along the tube and tighten the cap onto the bottle. Take precautions to avoid fluid spills.

Remote Connection

Plug the remote control into the socket on the rear of the machine marked “Remote

Control”. The remote control for the Mini-V is unique to this machine and is not compatible with other Rosco fog machines.

Power Connections

Ensure that the machine is plugged into an outlet rated for the proper voltage and amperage. The Mini-V is a 1,000 watt device and will draw 4.3A at 230 VAC or 9.1A at

115 VAC. Note: 230 volt machines are shipped with bare leads at the end of the power cord.

A proper electrical connector must be attached based on the local power requirements. If unsure how to do this, please contact Rosco or your local Rosco dealer for assistance. An example of properly wiring a UK 13A connector is shown below.

Green Earth Wire

Blue Neutral Wire

Brown Live Wire

Fuse

Outer Insulation

Cable grip

- 5 -

OPERATING THE MACHINE

Powering On

Make sure the unit is plugged in. Turn on the Main Power Switch that is located next to the power cord on the rear of the machine.

Heating

When switched on, the machine will begin to heat up to its optimal temperature. The initial heating cycle will take 7-10 minutes. When the green Ready Indicator light comes on, the machine is ready to make fog.

Using the Remote Control

The Remote Control can be operated directly on the machine by simply placing the remote’s magnetic backing on the machine body. The remote can be used at a distance using the 10 foot (3m) cable that is provided.

When the green Ready Indicator light is illuminated, the Mini-V is ready to make fog. To run the machine continuously, press the Fog Switch into the ON position toward the single line. The machine will make fog until the Fog Switch is moved back to the center,

OFF position. To operate the machine for MOMENTARY bursts of fog, press and hold the Fog Switch toward the two lines. The remote will return to the center, OFF position, and the machine will immediately stop making fog, when the Fog Switch is released.

Changing Fluid

The Mini-V consumes one liter of fluid per hour. When the fluid in the bottle has been depleted enough that the tube can no longer stay submerged, it is time to change fluid bottles.

It is recommended that you stop making fog when changing fluid bottles. Once fog production has halted, simply unscrew the fluid tube cap from the empty bottle and remove the tube. Take care to avoid dripping fluid onto the machine case or ground nearby, as it can be slippery. Replace the empty bottle with a new bottle of Rosco fog fluid, insert the fluid tube insuring that the filter at the end of the tube is fully submerged, and reattach the fluid cap. Resume making fog. Do not allow the machine to run dry of fluid.

Powering Down

After use, allow the machine to sit for several minutes before switching the Main Power

Switch to off. Turning off the power switch during fog production can cause damage to the heat exchanger. Allow machine to cool completely before packing or storing. Note:

The nozzle of the machine may remain hot for up to 10 hours after power is shut off.

If the machine will be unused for an extended period of time, follow the Storage and Shipment instructions listed under Maintenance to prepare the machine for long-term storage.

- 6 -

DUCTING FOG

It is often desirable to duct fog from the machine to another location on stage or in a set. This can be accomplished using flexible hose (“dryer hose”) or similar large diameter ducting such as 4in (100mm) PVC. Avoid sharp bends in the duct, which can create turbulence or back flow.

The duct should be positioned no closer than 2in (50mm) to the nozzle. An open airflow between the nozzle and opening of the duct is crucial to allow for aerosolization and create proper airflow. Placing ductwork or tubing directly over the nozzle or nozzle guard will cause damage to the machine and will void the warranty. Take all precautions to avoid fire hazards as the nozzle is extremely hot.

In some instances, it is desirable to use a fan to accelerate the fog through the ductwork.

Never run fog through the blades of a fan as the action of the impeller will cause condensation of fluid particles. To properly use a fan, create a vent in the ducting system such as a “branched wye” and introduce a fan at the vent point. This will create a low pressure point that “pulls or pushes” the fog through the ductwork.

Squirrel Cage Fan

Fog Machine Ducting Hose

Hose Adaptor

Contact Rosco or your local Rosco dealer for more advice on ducting fog.

TROUBLE SHOOTING

Problem Probable Cause(s) Suggested Remedy

Machine does not heat up

Fog output is weak

Machine is not turned on

No power at AC cable inlet

Ensure Main Power Switch is on

Check to make sure machine is plugged in properly. Check the circuit breaker.

Machine has overheated and internal thermal fuse is blown

Contact nearest Service Center for repair

Machine not turned on

Ensure Main Power Switch is on

Machine does not produce fog when the Fog Switch on the remote control is pressed

Machine not at operating temperature

Fluid filter above fluid line

Heat exchanger is clogged

Wait 7-10 minutes until green Ready

Indicator light illuminates on remote

Ensure filter is submerged inside the bottle

Contact nearest Service Center for repair

Additional help and information can be found on our website at www.rosco.com or by contacting Rosco or your local Rosco dealer.

- 7 -

MAINTENANCE

Before servicing the Rosco Mini-V, read and observe all the precautions listed in the

Important Safeguards section on pages 2-4 of this manual. Note: Any service that

is NOT described in the section below must be carried out by a Rosco service technician. Contact Rosco or your local Rosco dealer for more information on your repair and service needs.

Exterior Cleaning

Excessive dust, fluid residue, and dirt build-up will degrade the performance of the machine and may cause overheating to occur. To maintain adequate air flow and cooling, the outer casing and air vents of the machine must be cleaned periodically. Damage caused by lack of cleaning is not covered by the product warranty.

• Unplug the machine from power and allow the unit to cool completely before cleaning. Note: The output nozzle may remain hot for up to 10 hours after use.

• Remove dust from the air vents with a soft brush, cotton swab, vacuum or compressed air.

• Clean any fluid residues from the fog output area of the machine using a damp cloth.

• Clean the outer casing with a damp cloth only.

Storage & Shipment

Before storing the machine for an extended period of time, insure the following:

• Fluid bottle has been removed and securely capped

• Proper cleaning of exterior as described above

• Machine is properly boxed or covered to avoid dust build up on internal components

• If shipping, use original packaging or comparable protection to avoid damaging the machine in transit

- 8 -

SPECIFICATIONS

Physical

Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.75” (400mm)

Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.54” (191.4mm)

Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.21” (208.41mm)

Dry weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.9lbs (5.4Kg)

Performance

Operating time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . continuous

Warm up time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 minutes

Control and programming

Control options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Remote

Fluid system

Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 litre

Fluid consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 litre / hour

Connections

Remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC

AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC

Electrical

AC voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V / 230V, 50/60Hz

Thermal

Maximum ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°C (104°F)

Exterior surface temperature, steady state, at 20°C ambient . . . . . . . . . . . . . . . 40°C (104°F)

Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ETL approval (pending)

Dimensions

Dimensions are shown in [inches] and millimeters

- 9 -

1 YEAR LIMITED WARRANTY

Rosco Laboratories warrants to the first retail purchaser that this Product will be free from defects in workmanship and material for a period of twelve (12) months from the date of original purchase. For warranty service you must be able to provide proof of purchase.

Should this Product prove defective during the warranty period, please contact your local Rosco office for return authorization. No warranty service will be performed without Return Authorization. At Rosco’s sole discretion, covered Products will be repaired or replaced with new or refurbished equipment or a model of like kind and quality.

Exchanged or replaced parts and Products assume the remaining warranty period of the original Product covered by this limited warranty.

You are responsible for securely packaging the defective Product and returning it to

Rosco as per the instructions on the Return Authorization. Within North America, Rosco will ship the repaired or replaced Product to you freight prepaid. Shipments to other locations will be made freight collect. Do not return fog machines with fog fluid.

This warranty is not transferable and does not extend beyond the first retail purchase of the Product. This warranty does not cover damage to the Rosco product caused by parts not manufactured, distributed or certified by Rosco. Rosco is not obligated to provide warranty service should the product fail to be properly maintained or fail to function properly as a result of misuse, abuse, improper installation, neglect, improper shipping, damage caused by disasters such as flood, fire and lightning, improper electrical current or connection or service other than by a Rosco Authorized Servicer. If a claimed defect cannot be identified or reproduced, you will be held responsible for the costs incurred.

Unless otherwise stipulated by state law, all warranties expressed or implied are limited to the twelve (12) month period of this warranty.

THE WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL

OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED

WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT OR FITNESS FOR A PARTICULAR

PURPOSE. EXCEPT AS PROVIDED IN THIS WRITTEN WARRANTY AND UNLESS EXCLUSIONS

ARE SPECIFICALLY FORBIDDEN BY STATE LAW, NEITHER ROSCO NOR ITS AFFILIATES WILL

BE LIABLE FOR ANY LOSS, INCONVENIENCE, OR DAMAGE, INCLUDING DIRECT, SPECIAL,

INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING INJURY TO PERSONS OR PROP-

ERTY, RESULTING FROM THE USE OR INABILITY TO USE THE ROSCO PRODUCT, WHETHER

RESULTING FROM BREACH OF WARRANTY OR ANY OTHER LEGAL THEORY.

NOTE: USE OF ANY FLUID OTHER THAN A ROSCO BRAND FLUID WILL VOID THE WARRANTY.

- 10 -



  



 

 











  





This product meets the requirements, where applicable, of the following EC Standards and as such, comply with the European Council Directive 2006/95/EC:

60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008

BS EN 62233:2008

Safety of household and similar electrical appliances

Electromagnetic fields.

This product meets the requirements, where applicable, of the following EC Standards and as such, comply with the European Council Directive 2004/108/EC:

EN61000-3-3:1995 + A1:2001, Category II Flicker

EN 55014-1:2006

EN 61000-3-2:2006

RF voltage (discontinuous)

Electrostatic discharge to case

EN 61000-3-3:1995 + A1:2001 + A2 2005 Common mode fast transients (AC and DC ports)





 





www.rosco.com

- 11 -

©2014 by Rosco Laboratories, Inc.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project