Mitsubishi Electric GT14 Specifications

Side
ENGLISH
C
Date
Jan. 2012
This manual describes the part names, external dimensions, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are
the registered trademarks or trademarks of each company.
Effective Jan. 2012
Specifications are subject to change without notice.
© 2011 Mitsubishi Electric Corporation
Safety Precaution (Read these precautions before using.)
Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on circumstances, procedures indicated by
linked to serious results.
In any case, it is important to follow the directions for usage.
may also be
Manual
Number
(Model Code)
Contents
JY997D44801
(09R823)
Describes the GT14 hardware-relevant
content such as part names, external
dimensions,
mounting,
wiring,
specifications, and introduction to option
devices. (sold separately)
GOT1000 Series
Connection Manual
(Mitsubishi
Products) for GT
Works3
Describes system configurations of the
SH-080868ENG connection method applicable to GOT1000
(1D7MC2)
series and cable creation method.
(sold separately)
GOT1000 Series
Connection Manual
(Non-Mitsubishi
Products 1) for GT
Works3
Describes system configurations of the
SH-080869ENG connection method applicable to GOT1000
(1D7MC3)
series and cable creation method.
(sold separately)
GOT1000 Series
Connection Manual
(Non-Mitsubishi
Products 2) for GT
Works3
Describes system configurations of the
SH-080870ENG connection method applicable to GOT1000
(1D7MC4)
series and cable creation method.
(sold separately)
GOT1000 Series
Connection Manual
(Microcomputer,
MODBUS Products,
Peripherals) for GT
Works3
Describes system configurations of the
SH-080871ENG connection method applicable to GOT1000
(1D7MC5)
series and cable creation method.
(sold separately)
0.14 to 1.0mm2
AWG26 to AWG16
0.25 to 0.5 mm2
AWG24 to AWG20
Storage ambient
temperature
-20 to 60°C
2
0.14 to 0.5mm2
AWG26 to AWG20
0.14 to 0.2mm2
AWG26 to AWG24
-
Operating/Storage
ambient humidity
10 to 90% RH, non-condensing
Operating atmosphere
Must be free of lamp black, corrosive gas, flammable gas,
or excessive amount of electro conductive dust particles
and must not be exposed to direct sunlight (during
operation and storage).
Power consumption
0.5W or less (100mA/5VDC), supplied from the GOT
7. Installation
2
3
4
5
Tightening torque: 0.22 to 0.25N•m
Pin No.
Signal name
1
SG
2
SDB
3
SDA
4
RDB
5
RDA
3) Fix the RS-232/485 signal conversion
adapter to the GOT using the provided
M3 tapping screws.
Tightening torque: 0.3 to 0.6 N•m
8. Cautions on use of RS-232/485 signal conversion
adapter
5. 1pair/2pair/Terminating resistor setting switch
1pair/2pair
Terminating
resistor
48 (1.89")
3)
1)
OPERATION
PRECAUTIONS
36 (1.42")
• Power OFF the GOT, and then connect securely the RS-232/485 signal
conversion adapter to the specified connector in the GOT.
Poor connection may cause malfunction.
• Remove static electricity charged in the human body before handling the RS232/485 signal conversion adapter.
Static electricity may damage the stored data and elements.
17
(0.67")
Unit: mm (inch)
1)
1
2
3
4
5
6
1pair
ON
ON
-
-
-
OFF
2pair
OFF
OFF
-
-
-
OFF
110Ω
-
-
ON
OFF
OFF
OFF
OPEN
-
-
OFF
OFF
OFF
OFF
330Ω
-
-
OFF
ON
ON
OFF
<Setting example>
Format
No.
Switch No.
Set
value
• Set "1 pair" or "2 pairs" using the switches Nos. 1 and 2, and set the terminating
resistor value using the switches Nos. 3 to 6.
• Do not manipulate the setting switches while power is supplied to the RS-232/485
signal conversion adapter.
4)
Name
Contents
1) Turn off the GOT power.
2) Connect the RS-232/485 signal
conversion adapter to the RS-232
interface on the GOT.
4. Pin assignment
GT1455-QTBDE, GT1450-QLBDE, GT1455-QTBD, GT1450-QLBD
• Use the RS-232/485 signal conversion adapter in the environment that
satisfies the general specifications described in this manual. Not doing so can
cause an electric shock, fire, malfunction or product damage or deterioration.
Ferrules with
plastic sleeve
0.14 to 1.5mm2
AWG26 to AWG16
Setting
item
2. Part Names and External Dimensions
Stranded wire
1
The GT14-RS2T4-9P RS-232/485 signal conversion adapter (hereinafter referred to as
"RS-232/485 signal conversion adapter") converts the RS-232 communication
interface of the GOT into the RS-485 communication interface.
Applicable GOT units are shown below.
GOT
Solid wire
0 to 55°C
1. Overview
MOUNTING
PRECAUTIONS
• When disposing of the product, handle it as industrial waste.
Specifications
Operating ambient
temperature
1
2)
DISPOSAL PRECAUTIONS
Item
Electrical wire size
No. of wire per
terminal
5
6
JY997D44401
Revision
3.1 General Specifications
(Other specifications are the same as the GT14 main unit.)
GT14 User's Manual
User's Manual
Manual Number
3. Specifications
The following manuals are relevant to this product. When these loose manuals are
required please consult with our local distributor.
Manual name
GT14-RS2T4-9P
RS-232/485 Signal Conversion Adapter
• Refer to the table below for applicable wire sizes.
Related Manuals
4
B
JAPANESE
3
A
O
N
Side
2
B
JY997D44401C
1
Side
Switch No.
Terminating
resistor
1
2
3
4
5
6
110Ω
ON
ON
ON
OFF
OFF
OFF
OPEN
ON
ON
OFF
OFF
OFF
OFF
1pair
2pair
330Ω
OFF
OFF
OFF
ON
ON
OFF
OPEN
OFF
OFF
OFF
OFF
OFF
OFF
RS-485 terminal block
5-pin (Fixed type)
2)
GOT connector
D-Sub 9-pin female
6. Wiring
3)
Fixing screw hole
M3 tapping screws (accessory)
• For the detail, refer to GOT1000 Series Connection Manual.
4)
1pair/2pair/
Terminating resistor setting
switch
• 1Pair/2Pair
• Terminating resistor (110Ω, OPEN, 330Ω)
(At factory shipment: 2Pair, Terminating
resistor 330Ω)
Cable jacket to remove
5mm (0.19”)
Tightening torque
0.22 to 0.25 N•m
Recommended Tool (Screwdriver)
SZS 0.4×2.5 (Phoenix Contact Inc.)
• When using the RS-232/485 signal conversion adapter, select [Communication
setting] → [5V power supply] → [YES] on the utility screen in the GT14 main
unit.
For details, refer to the following.
→ GT14 User’s Manual (8.2 Utility Function List)
• The GT14 main unit whose hardware version is B or later supports the setting
whether or not 5V power is supplied.
In the hardware version A, the setting operation about 5V power supply is
invalid because 5V power is always supplied.
• When using the RS-232/485 signal conversion adapter, make sure that the
core OS version is V05.28.00AP or later and the standard monitor OS version
is V05.28.00 or later in the GT14 main unit.
For details, refer to the following.
→ GT14 User’s Manual (12.1.2 OS version confirmation)
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the
Mitsubishi products; damage, secondary damage, accident compensation
caused by special factors unpredictable by Mitsubishi; damages to products
other than Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
• This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310,
JAPAN
HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN