Switching components
WHEN RELIABLE SWITCHING MATTERS
The switching solution for all your applications!
Wherever mechanical, operator or electrical driven switching needs to be performed we offer a wide range of
solutions. For example: for high frequency switching applications the best solution is with our solid state relays.
Furthermore, we offer monitoring relays, which on threshold conditions, take the proper switching action.
466
Switching components – Table of contents
25 Monitoring products
28
Product overview
468
Product overview
512
Selection table
470
Selection table
514
G2RV
472
1-phase control
G2R-_-S
473
MY
475
Industrial plug-in relays
Industrial high power relays
3-phase control
K8AB-AS
516
K8AB-VS
517
K8AB-VW
518
LY
477
K8AB-PH
519
MKS
478
K8AB-PM
520
MKS(X)
479
K8AB-PA
521
G7J
481
K8AB-PW
522
G7L
482
61F-GP-N8
523
G7Z
483
61F-GPN-BT/-BC
525
61F-D21T
526
K7L
527
Solid state relays
26
Conductive level controller
Leakage controller
Product overview
484
Selection table
486
Limit switches
G3RV
489
Product overview
528
G3R-I/-O
490
Selection table
530
G3NA
491
Standard switches
G3PA
493
Panel mounted
Power controller
G3PE
494
G3PF
495
G3PW
496
G3ZA
497
Miniature switches
Enclosed switches
General purpose Z-size
Low voltage switchgear
29
HL-5000
533
WL
534
D4C
535
D4CC
536
D4E-_N
537
D4MC
538
Z
539
27
Product overview
498
Pushbutton switches
Selection table
500
Product overview
540
503
Selection table
543
Pushbutton switches
Mini contactor relays
J7KNA-AR
Mini motor contactors
J7KNA
505
Motor contactors
J7KN
506
Thermal overload relays
J7TKN
508
Motor protection circuit breakers
J7MN
510
Indicators
30
A16
544
A22
546
M16
548
M22
549
467
Switching components
Electromechanical relays
Electromechanical relays
NON-BENDABLE!
G2RV-SL500 – Reduce wiring time by using push-in technology and cross bars
With the G2RV-SL500 series only 2 steps are required to achieve a reliable connection between
wire and terminal. Just remove the isolation and push in the wire. Cross bars make your life even
easier, as they can be tailored by breaking pins away to meet your configuration requirements.
• No tools required
• Fits stranded wires (with ferrules) 0.5 - 2.5 mm²
• Fits solid wires 0.5 - 4.0 mm²
Request your free sample at:
www.omron-industrial.com/Slimrelay
Plug-in industrial relay
switching capacity up to 15 A
Interface/Power
1-pole
SPDT
General purpose/Power
2-pole
DPDT
1-pole
SPDT
2-pole
DPDT
3-pole
3PDT
10 A
10 A
6A
10 A
5A
15 A
Mech. flag
LED indicator
Mech. flag
LED indicator
Mech. flag
LED indicator
LED indicator
Slim outline
6 mm width
Lockable
test button
Lockable
test button
G2RV
(6 A)
G2RS1
G2RS2
LY1
Page 472
Page 473
Page 473
Page 477
468
Mech. flag
LED indicator
Mech. flag
LED indicator
Mech. flag
LED indicator
Lockable
test button
Lockable
test button
Lockable
test button
LY2
MKS2
MY2
MKS3
Page 477
Page 478
Page 475
LED indicator
Page 478
High power relays
up to 40 A
DC-switching
SPST-NO,
SPST-NO/
SPST-NC
1/2-pole
SPST/DPDT
30 A
10 A
10 A
5A
10 A
LED indicator
LED indicator
Mech. flag
LED indicator
Operation
indicators
Lockable
test button
Lockable
test button
Momentary
test button
4-pole, 4PST-NO
3PST-NO/SPST-NC
DPST-NO/DPST-NC
25 A
Electromechanical relays
4-pole
4PDT
40 A
25
3-pole
3PDT
Mirror
contact
LY3
LY4
MY4
MKS(X)
G7L
G7J
G7Z
Page 477
Page 477
Page 475
Page 479
Page 482
Page 481
Page 483
469
Selection table
Selection criteria
Category
Family
Interface/Power
G2RV
–
–
–
–
2-pole –
–


–
–
3-pole –
–
–
–
–
–
4-pole –
–
–
–


SPDT
DPDT
DPDT
4PDT
4PDT bifurcated
AgSnIn
AgSnIn
Ag
AgNi + Au
AgNi + Au
Max. switching Current 6 A
10 A
5A
10 A
5A
5A
Min. switching Current 10 mA at 5 VDC
100 mA at 5 VDC
10 mA at 5 VDC
1 mA at 5 VDC
1 mA at 1 VDC
0.1 mA at 1 VDC


–


13.0 mm
13.0 mm
21.5 mm
21.5 mm
21.5 mm
LED indication 





Mechanical flag 





–
–
–
–
–





Label 





Diode (DC coil) 





–
–
–
–
–
–
–








–
–








Gold clad/plate –
Width max. (Relay only) 5.2 mm
Momentary testbutton –
Momentary/ –
Lockable testbutton
Varistor (AC coil) –
CR network (AC coil) 
Screw 
Box clamp 
Screw-less clamp 
Page 472
473
475
Selection criteria
Category
Relay
terminals
G7J
G7L
G7Z
1-pole –
–
–
–

–
–
–
–
2-pole –
–
–
–
–

–
–
–
3-pole –
–
–
–
–
–
–
–
–
4-pole 



–
–



4PST-NO
3PST-NO/
SPST-NC
DPST-NO/
DPST-NC
SPST-NO
DPST-NO
4PST-NO
3PST-NO/
SPST-NC
DPST-NO/
DPST-NC
25 A
25 A
25 A
30 A
25 A
40 A
40 A
40 A
100 mA at
24 VDC
100 mA at
24 VDC
100 mA at
24 VDC
100 mA at
5 VDC
100 mA at
5 VDC
2 A at 24 VDC
2 A at 24 VDC
2 A at 24 VDC
Auxilary contact block –
Mirror contact
–
–
–
–
–



Momentary testbutton –
Contact 4PST-NO
configuration
Min. permissible load 100 mA at
24 VDC
Mounting
High power relays
Family
Max. switching current 25 A
–
–
–


–
–
–
Screw 








Quick-connect 





–
–
–
PCB terminals 





–
–
–
Screw –
–
–
–
–
–



DIN rail –
–
–
–
–
–



Clip (screw) 





–
–
–
Flange (screw) 





–
–
–
–
–
–


–
–
–
DIN rail (adapter) –
Page 481
470
MY

Contact material AgSnIn
Features
G2R-_-S
1-pole 
Contact configuration SPDT
Wiring to
socket
General purpose/Power
482
483
Electromechanical relays
Category
General purpose/Power
MKS(X)
–
–
–
–
–

–
2-pole –


–
–

–
–

3-pole –
–
–

–
–

–
–
4-pole –
–
–
–

–
–
–
–
DPDT
DPDT
bifurcated
3PDT
4PDT
DPDT
3PDT
SPST-NO
SPST-NO/
SPST-NC
Contact configuration SPDT
AgSnIn
AgSnIn
AgSnIn
AgSnIn
AgSnIn
AgSnIn
AgSnIn
AgSnIn
Max. switching Current 15 A
10 A
7A
10 A
10 A
10 A
10 A
10 A, 220 VDC;
15 A, 250 VAC
5 A, 220 VDC;
15 A, 250 VAC
Min. switching Current 100 mA at
5 VDC
100 mA at
5 VDC
10 mA at
5 VDC
100 mA at
5 VDC
100 mA at
5 VDC
10 mA at
1 VDC
10 mA at
1 VDC
10 mA at
24 VDC
10 mA at
24 VDC


–
–
–
–
–
–
21.5 mm
21.5 mm
31.5 mm
41.5 mm
34.5 mm
34.5 mm
34.5 mm
34.5 mm








Mechanical flag –
–
–
–
–


–
–
Momentary testbutton –
–
–
–
–
–
–
–
–
Momentary/ –
Lockable testbutton
–
–
–
–




Label –
–
–
–
–


–
–






Optional
for socket
Optional
for socket
–
–
–
–


–
–


–
–
–
–
–
–








Box clamp –
–
–
–
–


–
–
Screw-less clamp –
–
–
–
–
–
–
–
–
Gold clad/plate –
Width max. (Relay only) 21.5 mm
LED indication 
Diode (DC coil) 
Varistor (AC coil) –
CR network (AC coil) –
Screw 
Page 477
478
479
Electromechanical relays
Features
MKS
–
Contact material AgSnIn
Wiring to
socket
LY
1-pole 
25
Selection criteria
Family

Standard

Available
– No/not available
471
G2RV
Industrial plug-in relays
Non-bendable! First 6 mm relay with strong
mechanical pins
Drawing on years of experience, G2RV industrial slim relays have been added to
the product portfolio. With a width of 6 mm, they offer significant space saving
without compromising relay reliability or features. Push-in terminals and a full range
of accessories are available for simplifying wiring and saving time
•
•
•
•
•
Large plug-in pins – excellent connection
LED / mechanical flag – check operation
Transparent housing – check condition
Slim outline – space saving
Push-in / accessories – simple wiring
Ordering information
Input voltage
Order code
Screw terminals
Push-in terminals
12 VDC
G2RV-SL700-12 VDC
G2RV-SL500-12 VDC
24 VDC
G2RV-SL700-24 VDC
G2RV-SL500-24 VDC
24 VAC/VDC
G2RV-SL700-24 VAC/VDC
G2RV-SL500-24 VAC/VDC
48 VAC/VDC
G2RV-SL700-48 VAC/VDC
G2RV-SL500-48 VAC /VDC
110 VAC
G2RV-SL700-110 VAC
G2RV-SL500-110 VAC
230 VAC
G2RV-SL700-230 VAC
G2RV-SL500-230 VAC
Type
Description
Order code
Cross bar
2-pole
P2RVM-020_
Cross bar
3-pole
P2RVM-030_
Cross bar
4-pole
P2RVM-040_
Cross bar
10-pole
P2RVM-100_
Cross bar
20-pole
P2RVM-200_
PLC interface
Connect 8 relays and PLC output
P2RVC-8-O-F
Label
Plastic, for mounting on socket
R99-15 for G2RV
Label (Sticker)
Paper for mounting on socket or relay
R99-16 for G2RV
Separating plate
Provides isolation between adjacent relays to achieve 400 V isolation
P2RV-S
Relay only
Maintenance part for G2RV-SL-series 12 VDC
G2RV-1-S DC11
Relay only
Maintenance part for G2RV-SL-series 24 VDC and 24 VAC/VDC
G2RV-1-S DC21
Relay only
Maintenance part for G2RV-SL-series 48 VAC/VDC and 110, 230 VAC
G2RV-1-S DC48
Accessories
Note: _ Select colour: R=Red, S=Blue, B=Black
Specifications
Coil ratings
Contact form
SPDT
Input voltage
DC 12, 24, AC/DC 24, 48, AC 110, 230
Rated load
6 A at 250 VAC
6 A at 30 VDC
Max. switching voltage
400 VAC
Max. switching current
6A
Max. switching power
1500 VA / 180 W
Min. permissible load
10 mA at 5 VDC
Mechanical durability
5 Million operations
Electrical durability (rated load)
100 K operations (typical)
Dielectric strength
4 kV
Ambient temperature
-40 to 55°C
Approved standards
CE, VDE, cULus
Size in mm (HxWxD)
92.7x106.3x6.2 (push-in type) & 97.4x106.3x6.2 (screw type)
472
G2R-_-S
Industrial plug-in relays
Plug-in relay with enhanced features covers
a wide range of applications
G2RS series, which comes as standard with mechanical indicator and nameplate
covers a wide range interface applications.
Optionally available with gold clad contacts and diode, whilst the socket and crossbar
range are offering a maximum of flexibility during installation.
•
•
•
•
•
SPDT type 10A / DPDT type 5 A
Mechanical Flag, led indicator and momentary / lockable testbutton optional
Transparent housing
Screwless clamp terminal sockets available
Space saving – 16 mm width (including sockets)
Ordering information
Contact form
Diode
LED indicator
Test button
Gold clad 3 μm
Order code
( _ _ _ = coil voltage + AC/DC)
SPDT (1-pole)
no
no
no
DC
AC
G2R-1-S_ _ _ (S)
24
230
G2R-1-SN_ _ _ (S)
12, 24
24, 110, 230
G2R-1-SNI_ _ _ (S)
12, 24
12, 24, 110, 230
yes
G2R-1-SNI-AP3_ _ _ (S)
–
230
no
G2R-1-SND_ _ _ (S)
12, 24
–
G2R-1-SNDI_ _ _ (S)
24
–
yes
G2R-1-SNDI-AP3_ _ _ (S)
24
–
no
G2R-2-S_ _ _ (S)
24
24, 110, 240
G2R-2-SN_ _ _ (S)
12, 24, 48
24, 110, 230
yes
G2R-2-SN-AP3_ _ _ (S)
24
–
no
G2R-2-SNI_ _ _ (S)
12, 24
12, 24, 110, 230
yes
G2R-2-SNI-AP3_ _ _ (S)
–
230
no
G2R-2-SD_ _ _ (S)
–
–
G2R-2-SND_ _ _ (S)
12, 24
–
yes
G2R-2-SND-AP3_ _ _ (S)
24
–
no
G2R-2-SNDI_ _ _ (S)
12, 24
–
yes
G2R-2-SNDI-AP3_ _ _ (S)
24
–
no
yes
yes
yes
no
yes
DPDT (2-pole)
no
no
no
yes
yes
yes
no
no
yes
yes
*1
Common coil voltages *1
Other coil voltages available. Please see specifications.
Sockets & accessories
Order code
DIN rail
PCB
Screwless clamp
Screw
Soldering
Socket
Clip
Cross bar
AC type
Cross bar
DC type
Name plate
Socket
Socket
G2R-1-S
P2RF-05-S
P2CM-S
P2RM-SR
P2RM-SB
R99-11
P2RF-05-E
P2R-05P
G2R-2-S
P2RF-08-S
P2CM-S
P2RM-SR
P2RM-SB
R99-11
P2RF-08-E
P2R-08P
Specifications
Coil ratings
Rated voltage
Must operate voltage
Must release voltage
Max. voltage
Power consumption (approx.)
% of rated voltage
AC
24 V, 110 V, 120 V, 230 V, 240 V
80% max.
30% max.
110%
0.9 VA (60 Hz)
DC
6 V, 12 V, 24 V, 48 V
70% max.
15% max.
110%
0.53 W
25
Contact ratings
Number of poles
1-pole
Load
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7)
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7)
Rated load
10 A at 250 VAC
10 A at 30 VDC
7.5 A at 250 VAC
5 A at 30 VDC
5 A at 250 VAC
5 A at 30 VDC
2 A at 250 VAC
3 A at 30 VDC
Rated carry current
10 A
5A
Max. switching voltage
440 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current
10 A
Max. switching power
2,500 VA, 300 W
Failure rate (reference value)
100 mA at 5 VDC
Mechanical life
AC: 10,000,000 operations min., DC: 20,000,000 operations min.
Electrical life
100,000 operations min.
2-pole
5A
1,875 VA, 150 W
1,250 VA, 150 W
Electromechanical relays
For type
500 VA, 90 W
10 mA at 5 VDC
473
G2R-_-S
Industrial plug-in relays
Technical data
Item
1-pole
Contact material
AgSnIn
Operating time
15 ms max.
15 ms max.
Release time
AC: 10 ms max., DC: 5 ms max.
AC: 15 ms max., DC: 10 ms max.
Dielectric strength
5,000 VAC (coil-contact)
5,000 VAC (coil-contact)
Ambient temperature
Operating: -40 to 70°C (no icing or condensation)
Size in mm (HxWxD)
35.5x13x29
474
2-pole
MY
Industrial plug-in relays
Versatile plug-in relay that sets the standard
Over 500 million pieces of this mini power relay have been manufactured since
introduction and successfully been used in many different applications. Bifurcated
contacts optionally are available to achieve reliable low current switching during the
entire electrical life. Full range of sockets covering mounting by screw, box clamp and
screw less clamp method.
•
•
•
•
•
DPDT type 10 A / 4PDT type 5 A
Mechanical flag, led indicator and momentary / lockable testbutton optional
Transparent housing
Low power switching (1 mA at 5 VDC) / Bifurcated 4PDT (0.1 mA at 1 VDC)
Screwless clamp terminal sockets available
Ordering information
Contact form
DPDT
Diode
no
DPDT
LED
indicator
Lockable test
button
Order code ( _ _ _ = coil voltage + AC/DC)
Standard coil polarity
Reversed coil polarity
DC
AC
no
no
MY2_ _ _ (S)
–
12, 24
12, 24, 48/50, 110/120,
220/240
MY2N_ _ _ (S)
–
12, 24
24, 110/120, 220/240
MY2N-D2_ _ _ (S)
–
24
–
MY2IN_ _ _ S)
–
12, 24, 48
12, 24, 110/120, 220/240
–
MY2IN1_ _ _ (S)
12, 24
–
MY2IN-D2_ _ _ (S)
–
24
–
–
MY2IN1-D2_ _ _ (S)
24
–
MY4_ _ _ (S)
–
12, 24, 48, 100/110, 125
12, 24, 48/50, 110/120,
220/240
MY4N_ _ _ (S)
–
12, 24, 48, 100/110
24, 110/120, 220/240
MY4N-D2_ _ _ (S)
–
12, 24
–
MY4IN_ _ _ (S)
–
12, 24, 48
12, 24, 48/50, 110/120,
220/240
–
MY4IN1_ _ _ (S)
12, 24, 48
–
MY4IN-D2_ _ _ (S)
–
24
–
–
MY4IN1-D2_ _ _ (S)
24, 48
–
yes
DPDT
yes
DPDT
no
yes
DPDT
DPDT
yes
DPDT
4PDT
no
4PDT
no
no
yes
4PDT
yes
4PDT
no
yes
4PDT
4PDT
yes
4PDT
*1
Common coil voltages *1
Other coil voltages available. Please see specifications.
Note:- MY4 also available with bifurcated contacts => example MY4Z
- MY2 and MY4 AC 110/120, 220/240 types also available with suppression => example MY4N-CR
Sockets & accessories
Input terminals separated from output terminals
Screw-less clamp
Electromechanical relays
Order code
Box clamp
For type
Socket
Clip
Cross bar
AC type
Cross bar
DC type
Name plate
Socket
Metal spring clip Plastic holding
clip
Label
MY2
PYF08S
PYCM-08S
PYDM-08SR
PYDM-08SB
R99-11
PYF14-ESS
PYC-0
PYC-35
PYCTR1
MY4
PYF14S
PYCM-14S
PYDM-14SR
PYDM-14SB
R99-11
PYF14-ESS
PYC-0
PYC-35
PYCTR1
Combined input/output terminals
Order code
Box clamp
Socket
Clip
(set = 2 pcs)
Clip for MY2IN
(set = 2 pcs)
Socket
Metal spring clip Plastic holding
clip
Label
MY2
PYF08A-N
PYC-A1
PYC-E1
PYF14-ESN
PYC-0
PYC-35
PYCTR1
MY4
PYF14A-N
PYC-A1
PYF14-ESN
PYC-0
PYC-35
PYCTR1
25
Screw terminal
Order code
475
MY
Industrial plug-in relays
Specifications
Coil ratings
Rated voltage
Must operate voltage
Must release voltage
Max. voltage
Power consumption (approx.)
110%
1.0 to 1.2 VA (60 Hz)
% of rated voltage
AC 6 V, 12 V, 24 V, 48/50 V
80% max
30% min.
110/120 V, 220/240 V
0.9 to 1.1 VA (60 Hz)
DC 6 V, 12 V, 24 V, 48 V, 100/110 V
10% min.
0.9 W
Contact ratings
Item
Rated load
2-pole
4-pole
4-pole (bifurcated)
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7)
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7)
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7)
5 A at 250 VAC
2 A at 250 VAC
3 A at 250 VAC
0.8 A at 250 VAC
3 A at 250 VAC
0.8 A at 250 VAC
5 A at 30 VDC
2 A at 30 VDC
3 A at 30 VDC
1.5 A at 30 VDC
3 A at 30 VDC
1.5 A at 30 VDC
500 VA, 150 W
1,250 VA, 150 W
500 VA, 150 W
Rated carry current
10 A
5A
Max. switching voltage
250 VAC, 125 VDC
250 VAC, 125 VDC
Max. switching current
10 A
Max. switching power
2,500 VA, 300 W
Failure rate (reference value)
5 VDC at 1 mA
Mechanical life
AC: 50,000,000 operations min., DC: 100,000,000 operations min.
20,000,000 operations min.
Electrical life
500,000 operations min.
100,000 operations min.
5A
1,250 VA, 300 W
1 VDC at 1 mA
200,000 operations min.
Technical data
Item
2-pole
4-pole
Contact Material:
Ag
AgNi + Au
Operating time
20 ms max.
Release time
20 ms max.
Dielectric strength
2,000 VAC
Ambient temperature
Operating: -55 to 70°C (no icing)
Size in mm (HxWxD)
28x21.5x36
476
1,250 VA, 150 W
1 VDC at 100 μA
LY
Industrial plug-in relays
Miniature 15 A power relay
LY-series comes in SPDT, DPDT, 3PDT and 4PDT types covering depending on
number of poles 10 or even 15A rated load. Bifurcated contacts available for DPDT
configuration only, whilst the optional Diodes for DC and CR circuit for AC coils are
available for all plug-in types.
•
•
•
•
•
SPDT type 15 A / DPDT, 3PDT and 4PDT type 10 A
Led indicator optional
Transparent housing
Suppression by optional Built-in Diodes (DC only) or CR network (AC-types)
DIN rail mounting by socket. PCB and Flange mounting available
Ordering information
Contact form
LED indicator
Diode
Plug-in/solder PCB
Order code *1
Common coil voltages*2
( _ _ _ = coil voltage + AC/DC) DC
UpperAC
mounting
plug-in/solder
yes
no
Terminals
SPDT (1 pole)
no
no
LY1_ _ _
24
–
SPDT (1 pole)
yes
yes
LY1N-D2_ _ _
24
–
DPDT (2 pole)
no
no
LY2_ _ _
12, 24, 100/110
24, 100/110, 110/120, 220/240
DPDT (2 pole)
DPDT (2 pole)
yes
yes
3PDT (3 pole)
no
no
no
no
yes
LY2F_ _ _
–
220/240
yes
no
LY2N-D2_ _ _
24
–
LY3_ _ _
24
–
LY4_ _ _
12, 24, 100/110, 125 24, 100/110, 230
LY4N-D2_ _ _
24
4PDT (4 pole)
4PDT (4 pole)
*1
*2
yes
yes
–
For other options like CR suppression, please see specifications.
Other coil voltages available. Please see specifications.
Sockets & accessories
Order code
DIN rail
PCB
Screw
Soldering
For type
Socket
Clip (set = 2 pcs) Socket
Clip (set = 2 pcs.)
LY1/LY2
PTF08A-E
PYC-A1
PT08-0
PYC-P
LY2 CR-type
PTF08A-E
Y92H-3
PT08-0
PYC-1
LY3
PTF11A-E
PYC-A1
PT11-0
PYC-P
LY4
PTF14A-E
PYC-A1
PT14-0
PYC-P
Specifications
Poles
Technical data
Rated voltage
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power consumption
(approx.)
% of rated voltage
1 or 2
AC
6 V, 12 V, 24 V, 50 V
80% max.
30% min.
110%
100/110 V, 110/120 V, 200/220 V, 220/240 V
0.9 to 1 VA (60 Hz)
DC 6 V, 12 V, 24 V, 48 V, 100/110 V
3
AC
10% min.
6 V, 12 V, 24 V, 50 V, 100/110 V, 200/220 V
80% max.
DC 6 V, 12 V, 24 V, 48 V, 100/110 V
4
AC
1.0 to 1.2 VA (60 Hz)
30% min.
0.9 W
110%
10% min
6 V, 12 V, 24 V, 50 V, 100/110 V, 200/220 V
80% max.
DC 6 V, 12 V, 24 V, 48 V, 100/110 V
30% min.
Contact material
AgSnIn
Operating time
25 ms max.
Release time
25 ms max.
Dielectric strength
1,000 VAC
Ambient temperature *1
-25 to 70°C
*1
Electromechanical relays
Coil ratings
See datasheet for more details.
1.6 to 2.0 VA (60 Hz)
1.4 W
110%
10% min
1.95 to 2.5 VA (60 Hz)
1.5 W
25
Contact ratings
Relay
Single contact 1-pole
Single contact 2-, 3- or 4-pole
Bifurcated contacts 2-pole
Load
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7)
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7)
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7)
Rated load
110 VAC at 15 A
110 VAC at 10 A
110 VAC at 10 A
110 VAC at 7.5 A
110 VAC at 5 A
110 VAC at 4 A
24 VDC at 15 A
24 VDC at 7 A
24 VDC at 10 A
24 VDC at 5 A
24 VDC at 5 A
24 VDC at 4 A
Rated carry current
15 A
10 A
7A
Max. switching voltage
250 VAC, 125 VDC
250 VAC, 125 VDC
250 VAC, 125 VDC
Max. switching current
15 A
10 A
Max. switching power
1,700 VA
1,100 VA
1,100 VA
825 VA
550 VA
440 VA
360 W
170 W
240 W
120 W
120 W
100 W
Failure rate (reference value)
100 mA at 5 VDC
100 mA at 5 VDC
Mechanical life
AC: 50,000,000 operations min., DC: 100,000,000 operations min.
Electrical life
1-, 3-, 4-pole: 200,000 operations min., 2-pole: 500,000 operations min.
7A
10 mA at 5 VDC
477
MKS
Industrial plug-in relays
Exceptionally reliable general purpose relay
with 8 or 11 plug-in pins for round sockets
MK relay breaks compared to its size relatively large currents. The AgSnIn contacts
ensure long electrical lifetime (min. 100,000 operations). Wide switching range from
10 mA at 1 VDC upto 10 A at 250 VAC.
•
•
•
•
8-pin DPDT and 11-pin 3PDT contact types
Switching current up to 10 A
Lockable test button for easy testing
Temperature rating from -40°C up to 60°C
Ordering information
Contact form
Mechanical indicator & lockable
test button
LED indicator
Diode
Order code *1
( _ _ _ = coil voltage + AC/DC)
Common coil voltages *2
DC
AC
DPDT (2-pole)
yes
no
no
MKS2PI
12, 24, 110
24, 110, 230
yes
MKS2PIN
24
24, 230
no
MKS3PI-5
12, 24, 48, 110
12, 24, 110, 230
yes
MKS3PI-D-5
24
N/A
no
MKS3PIN-5
12, 24
24, 110, 230
yes
MKS3PIN-D-5
24
N/A
3PDT (3-pole)
yes
*1
*2
Many various terminal arrangements possible, please see specifications.
Other coil voltages available. Please see specifications.
Sockets & accessories
Order code
DIN rail
Screw
Box clamp
For type
Socket
Clip (set= 2 pcs.)
Socket
MKS2
PF083A-E
PFC-A1
-
PF083A-D
MKS3
PF113A-E
PFC-A1
PF113A-N
PF113A-D
Must operate voltage
Must release voltage
Max. voltage
Power consumption
(approx.)
110%
2.3 VA (60 Hz)
Specifications
Coil ratings
Rated voltage
% of rated voltage
AC
6 V, 12 V, 24 V, 100 V, 110 V, 120 V, 200 V, 80% max.
220 V, 230 V, 240 V
30% min.
DC
6 V, 12 V, 24 V, 48 V, 100 V, 110 V
15% min.
Contact ratings
Load
2- or 3-pole
Resistive load
(cos = 1)
Contact material
AgSnIn
Rated load
NO: 10 A at 250 VAC
NC: 5 A at 30 VDC
Rated carry current
10 A
Max. switching voltage
250 VAC, 250 VDC
Max. switching current
10 A
Max. switching power
2,500 VA/ 300 W
Mechanical life
5,000,000 operations min.
Electrical life
100.000 operations min.
Inductive load
(cos = 0.4; L/R = 7)
7 A at 250 VAC
–
1,250 VA/150 W
Technical data
Operating time
AC: 20 ms max., DC: 30 ms max.
Release time
20 ms max. (40 ms max. for built-in Diode relays)
Dielectric strength
2,500 VAC (coil-contact)
Ambient temperature
Operating: -40 to 60°C (with no icing or condensation)
Size in mm (HxWxD)
34.5x34.5x53.3
478
2.7 VA (50 Hz)
1.4 W
MKS(X)
Industrial plug-in relays
Power relay that can switch 220 VDC, 10 A
(resistive load)
The MK-S(X) is the smallest relay in the world that can switch 220 VDC 10 A resistive
load. Applications in loads are encountered.
•
•
•
•
•
Suitable for DC-switching
DC load switching up to 10 A; 220 VDC (resistive load)
AC load models are capable of switching up to 15 A; 250 VAC (resistive load)
SPST-NO/SPST-NC contact form enables contact welding detection
Lockable test button for easy testing
Ordering information
Models for DC loads
Contact form
LED indicator & lockable test button
Order code
( _ _ _ = coil voltage + AC/DC)
Common coil voltages *1
DC
AC
SPST-NO (1-pole)
yes
MKS1XTIN-10
12, 24, 48, 110, 220
24, 110, 230
SPST-NO/SPST-NC (2-pole)
yes
MKS2XTIN-11
12, 24, 48, 110, 220
24, 110, 230
*1
Other coil voltages available. Please see specifications.
Models for AC loads
Contact form
LED indicator & lockable test button
Order code
( _ _ _ = coil voltage + AC/DC)
Common coil voltages *1
DC
AC
SPST-NO (1-pole)
yes
MKS1TIN-10
12, 24, 48
24, 110, 230
SPST-NO/SPST-NC (2-pole)
yes
MKS2TIN-11
12, 24, 48
24, 110, 230
*1
Other coil voltages available. Please see specifications.
Sockets & accessories
Order code
DIN rail
PCB
Screw
Soldering
Socket
No built-in diode
Built-in diode
P7MF-06
P7MF-06-D
Clip (set= 2 pcs.)
Socket
Clip (set= 2 pcs.)
PYC-A2
P7M-06P
PYC-A2
Specifications
Rated voltage
Must operate
voltage
Must release voltage
80% max.
30% min. (60 Hz)
Max. voltage
Power consumption (approx.)
110%
2.3 VA (60 Hz)
% of rated voltage
AC
DC
24 V, 100 V, 110 V, 120 V, 200 V,
220 V, 230 V, 240 V
12 V, 24 V, 48 V, 110 V, 220 V
25% min. (50 Hz)
2.7 VA (50 Hz)
15% min.
1.5 W
Contact ratings
Model
Models for DC Loads
Models for AC Loads
MKS1XT(I)(N)-10
MKS2XT(I)(N)-11
MKS1T(I)(N)-10
MKS2T(I)(N)-11
Contact form
SPST-NO
SPST-NO/SPST-NC
SPST-NO
SPST-NO/SPST-NC
Load
Resistive load
Resistive load
Resistive load
L/R = 7 ms
Contact configuration
Contact material
Rated load
Rated carry current
Max. switching voltage
Resistive load
DC13 class
Inductive load
L/R = 7 ms
DC13 class
NO Double-break
Double-break
Double-break
Double-break
NC –
Single-break
–
Single-break
AgSnIn
AgSnIn
AgSnIn
AgSnIn
NO 10 A, 220 VDC
5 A, 220 VDC
0.4 A, 220 VDC
5 A, 220 VDC
3 A, 220 VDC
0.2 A, 220 VDC
15 A, 250 VAC
15 A, 250 VAC
NC –
2 A, 220 VDC
0.3 A, 220 VDC
0.1 A, 220 VDC
–
5 A, 250 VAC
NO 10 A
5A
15 A
15 A
NC –
2A
–
5A
NO 220 VDC
220 VDC
250 VAC
250 VAC
NC –
Max. switching current
Max. switching capacity
(reference value)
–
NO 10 A
5A
15 A
15 A
NC –
2A
–
5A
NO 2,200 W
NC –
25
Inductive load
–
–
Electromechanical relays
Coil ratings
1,100 W
–
–
3,750 VA
3,750 VA
440 W
–
–
–
1,250 VA
479
MKS(X)
Industrial plug-in relays
Note: These values apply to a switching frequency of 30 times per minute for DC Load models and 20 times per minute for AC Load models.
Technical data
Operating time
AC: 20 ms max., DC: 30 ms max.
Release time
20 ms max.
Dielectric strength
2,500 VAC (coil-contact)
Ambient temperature
Operating: -40 to 60°C (with no icing or condensation)
Size in mm (HxWxD)
34.5x34.5x52.1
Mechanical endurance
1,000,000 operations min. (at 18,000 operations/hr)
Electrical endurance*1
100.000 operations min. (at rated load and maximum switching frequency)
*1
Measured at an ambient temperature of 23°C
480
G7J
Industrial high power relays
High capacity, high dielectric strength
4 pole power relay
G7J series developed for switching resistive, inductive as well as motor loads.
No contact chattering for momentary voltage drops up to 50% of rated voltage.
High dielectric strength (4KV) between coil and contacts as well as between different
polarity contacts.
•
•
•
•
•
25 A Rated current
4PST-NO, 3PST-NO / SPST-NC or DPST-NO / DPST-NC
Bifurcated contacts optional
Terminals: Screw, Quick-connect or PCB pins
Mounting by insertion into a clip or just by screws (flange type)
Ordering information
Contact form
4PST-NO
PCB
W-bracket
mounting
PCB
Quick-connect Screw
Order code *1
( _ _ _ = coil voltage + AC/DC)
yes
no
yes
no
no
G7J-4A-P_ _ _
12, 24
200/240
no
yes
no
yes
G7J-4A-B_ _ _
24
–
no
G7J-4A-T_ _ _
12, 24
200/240
G7J-3A1B-P_ _ _
24
–
yes
G7J-3A1B-B_ _ _
24
–
no
G7J-3A1B-T_ _ _
24
200/240
no
G7J-2A2B-P_ _ _
24
–
Must release voltage
Max. voltage
Power consumption (approx.)
110%
1.8 to 2.6 VA
Mounting
Terminal
yes
3PST-NO/SPST-NC
yes
no
yes
no
yes
no
DPST-NO/SPST-NC
DPST-NO/DPST-NC
*1
*2
no
yes
yes
no
yes
Common coil voltages *2
DC
AC
For other options like bifurcated contacts, please see specifications.
Other coil voltages available. Please see specifications.
Accessories
For type
Order code
W-bracket
G7J Screw terminal type
R99-04 for G5F
G7J Quick Connect type
Specifications
Coil ratings
Rated voltage
Must operate
voltage
% of rated voltage
24, 50, 100 to 120, 200 to 240
DC
6, 12, 24, 48, 100
75% max.
15% min.
10% min.
2.0 W
Electromechanical relays
AC
Contact ratings
4-pole
Resistive load
cos = 1
Inductive load
cos = 0.4
Rated load
NO: 25 A at 220 VAC
(24 A at 230 VAC)
NC: 8 A at 220 VAC
(7.5 A at 230 VAC)
Rated carry current
NO: 25 A (1 A), NC: 8 A (1 A)
Max. switching voltage
250 VAC
Max. switching current
NO: 25 A (1 A), NC: 8 A (1 A)
Mechanical life
1,000,000 operations min.
Electrical life
100,000 operations min.
Resistive load
NO: 25 A at
30 VDC
NC: 8 A at
30 VDC
125 VDC
25
Item
Note: Values between () indicate bifurcated contact specification.
Technical data
Contact material
Ag alloy
Operating time
50 ms max.
Release time
50 ms max.
Dielectric strength
4,000 VAC
Ambient temperature
Operating: -25 to 60°C (no icing)
481
G7L
Industrial high power relays
High capacity, high dielectric strength
1 or 2 pole general purpose power relay
G7L fits many applications from motor driver and power supply switching in office
equipment to switching controller for air-conditioning compressor. No contact
chattering for momentary voltage drops up to 50% of rated voltage. G7L series
can be mounted on DIN-rail by using separate adaptor, whilst relay is connected by
screw or quick-connect terminals.
•
•
•
•
•
SPST-NO – 30 A
DPST-NO – 25 A
Wide input range AC coils 100-120, 200-240 V at either 50 or 60 Hz
Terminals: Screw, Quick-connect or PCB pins
Mounting by insertion into a clip, by screws (flange type) or by DIN-rail adaptor
Ordering information
PCB
DIN-rail
DIN Rail
adaptor
front
connecting
socket
Flange
(screw)
E-bracket PCB
mounting
Quickconnect
Screw
Order code*1
( _ _ _ = Coil Voltage + AC/DC)
no
yes
no
yes
yes
no
G7L-1A-T_ _ _
24
100/120, 200/240
G7L-2A-T_ _ _
12, 24
24, 100/120, 200/240
G7L-1A-TUB_ _ _
–
100/120, 200/240
G7L-2A-TUB_ _ _
24
24, 200/240
yes
G7L-2A-BUB_ _ _
–
200/240
no
G7L-2A-P_ _ _
24
–
Contact form Mounting
SPST-NO
Terminals
yes
no
DPST-NO
SPST-NO
no
no
yes
no
DPST-NO
no
yes
*1
*2
no
yes
Common Coil Voltages *2
DC
AC
For other options like bifurcated contacts, please see specifications.
Other coil voltages available. Please see specifications.
Accessories
For type
Order code
DIN-rail front connecting socket DIN Rail adaptor
E-Bracket mounting
Coverplate electric shock protection
G7J Screw terminal type
–
P7LF-D
R99-07G7L
P7LF-C
G7J Quick Connect type
P7LF-06
P7LF-D
R99-07G7L
–
Specifications
Coil Ratings
Rated voltage
Rated current
Coil resistance
Must operate voltage
AC (~)
12 V
142 mA
–
75% max.of rated voltage 15% min. of rated voltage 110% of rated voltage
24 V
71 mA
–
50 V
34 mA
–
100 to 120 V
17.0 to 20.4 mA
–
74 V
18 V
132 V
200 to 240 V
8.5 to 10.2 mA
–
150 V
36 V
264 V
6V
317 mA
18.9 Ohm
75% max. of rated voltage 15% min. of rated voltage 110% of rated voltage
12 V
158 mA
75 Ohm
24 V
79 mA
303 Ohm
48 V
40 mA
1220 Ohm
100 V
19 mA
5260 Ohm
DC (=)
Must release voltage
Max. voltage
Power consumption
(approx.)
1.7 to 2.5 VA (60 Hz)
1.9 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%/20% for AC rated current and ±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. ~ indicates AC and = indicates DC (IEC417 publications).
Contact Ratings
Model
G7L-1A-TJ/G7L-1A-BJ
G7L-2A-TJ/G7L-2A-BJ
G7L-1A-P/G7L-2A-P
Resistive load
(cos  = 1)
Inductive load
(cos  = 0.4)
Resistive load
(cos  = 1)
Rated load
30 A, 220 VAC (~)
25 A, 220 VAX (~)
25 A, 220 VAC (~)
20 A, 220 VAC (~)
Rated carry current
30 A
25 A
20 A
Max. switching voltage
250 VAC (~)
Max. switching current
30 A
25 A
20 A
Max. switching power
6,600 VAC (~)
5,500 VAC (~)
4,400 VAC (~)
Failure rate*1 (reference value) 100 mA, 5 VDC (=)
*1
P level: 60 = 0.1×10-6/operation
482
5,500 VAC (~)
Inductive load
(cos  = 4.4)
Resistive load
(cos  = 1)
Inductive load
(cos  = 4.4)
G7Z
Industrial high power relays
Compact 160 Amp Power Relay
G7Z series provides a compact, cost efficient solution for applications such as
inverters, UPS, solar and fuel-cell battery circuits. Relay in combination with auxiliary
contact block meets EN 60947-4-1. Coil ratings are available in 12 and 24 VDC.
Power consumption is less than 4 watts.
•
•
•
•
•
Switching current 160 A (40 A rating / 4-pole / IEC-AC1)
Switching voltage 440 VAC
Safety function with mirror contacts in various configurations
Power consumption less than 4 Watts
Low Switching Noise (70 dB)
Ordering information
Relay with Auxiliary Contact Block (for Screw Terminals)
Contact configuration
Relay
Auxiliary contact block
4PST-NO
DPST-NO
3PST-NO/SPST-NC
DPST-NO/DPST-NC
Rated voltage
Order code
12, 24 VDC
G7Z-4A-20Z
SPST-NO/SPST-NC
G7Z-4A-11Z
DPST-NC
G7Z-4A-02Z
DPST-NO
G7Z-3A1B-20Z
SPST-NO/SPST-NC
G7Z-3A1B-11Z
DPST-NC
G7Z-3A1B-02Z
DPST-NO
G7Z-2A2B-20Z
SPST-NO/SPST-NC
G7Z-2A2B-11Z
DPST-NC
G7Z-2A2B-02Z
Specifications
Coil ratings
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption (approx.)
10% min.
110%
Approx. 3.7 W
% of rated voltage
12 VDC
333 mA
39 
24 VDC
154 mA
156 
75% max.
Note: - Rated current and coil resistance were measured at a coil temperature of 23°C with coil resistance of ±15%.
- Operating characteristics were measured at a coil temperature of 23°C.
- The maximum allowable voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient temperature of 23°C.
Contact Ratings - Relay
G7Z-4A-_Z, G7Z-3A1B-_Z, G7Z-2A2B-_Z
Resistive load
Contact structure
Rated carry current
Ag alloy
NO
40 A at 440 VAC
22 A at 440 VAC
5 A at 110 VDC
NC
25 A at 440 VAC
10 A at 440 VAC
5 A at 110 VDC
NO
40 A
22 A
5A
NC
25 A
10 A
5A
Maximum contact voltage
Maximum contact current
Maximum switching capacity
Resistive load L/R = 1 ms
Double break
Contact material
Rated load
Inductive load cos phi = 0.3
Electromechanical relays
Item
480 VAC
125 VDC
NO
40 A
NC
25 A
NO
17,600 VA
9,680 VA
550 W
NC
11,000 VA
4,400 VA
550 W
25
Failure rate P value (reference value) 2 A at 24 VDC
Note: The ratings for the auxiliary contact block mounted on the G7Z are the same as those for the G73Z auxiliary contact block.
Contact Ratings - Auxiliary Contact Block
Item
G7Z-4A-_Z, G7Z-3A1B-_Z, G7Z-2A2B-_Z
Resistive load
Contact structure
Double break
Contact material
Au clad + Ag
Rated load
1 A at 440 VAC
Rated carry current
1A
Maximum contact voltage
480 VAC
Maximum contact current
1A
Maximum switching capacity
440 VA
Inductive load cos phi = 0.3
Resistive load L/R = 1 ms
0.5 A at 440 VAC
5 A at 110 VDC
125 VDC
220 VA
110 W
Failure rate P value (reference value) 1 mA at 5 VDC
483
Solid state relays
COMPACT SOLID STATE RELAYS
G3_ series – Reliable interfacing and power switching
With a wide variety of output currents and voltages, our control-panel mounted types of power switching SSRs are
available with (G3PE) and without (G3NA) built-in heat-sink. The compact SSRs for I/O Interfacing G3RV & G3R offer
high-speed models (G3R).
• Industrial 6 mm ‘slim’ SSR which is G2RV compatible (G3RV)
• G2RS compatible high-speed interface solutions (G3R-I/O)
• G3NA with 5-90 A output current, G3PB up to 45 A
• Output voltages up to 480 VAC / 200 VDC available on G3NA
• Effectively absorbing of external surge thanks to the built-in varistor
Type of application
Power switching (up to 90 A)
Interfacing
Single-phase
Type and size?
Socket
mounted I/O
6 mm slim
Socket
mounted I/O
Compact
hockey puck style
up to 90A
G3RV
G3R-I/O
G3NA
Page 489
Page 490
Page 491
484
Integrated
heat sink
up to 45 A
Integrated heater
burnout and
SSR short-circuit
failure detection
G3PA
G3PE
G3PF
Page 493
Page 494
Page 495
Integrated heat sink
replaceable powercartridge
up to 60 A
Power controlling
Three-phase
Single phase
Integrated
heat sink
up to 45 A
Integrated
heat sink
up to 60 A
G3PE
G3PW
G3ZA
Page 496
Page 497
Page 494
Page 495
26
Solid state relays
Multi channel up to 8
solid state relays
485
Selection table
Category
Selection criteria
Model
Control panel mounting type
G3RV
Type of load Output module
G3NA
Output Module
Normal resistors
Middle and long wave IR heater
Transformers and inductors
1-phase control –
–
–

2-phase control –
–
–
–
3-phase control –
–
–
–
Signal switching
Signal switching
Heater control, motor control
Function Signal switching
Max. current rating 2 A (AC); 3 A (DC)
Load voltage/
current [VAC]
G3R-I/O
Input Module
100 mA
2A
90 A
24 to 240 –
–
–

100 to 240 
–

–
200 to 480 –
–
–

4 to 32






–
–
–
–
–
100 to 120 VAC  110 VAC ±10%

–

200 to 240 VAC  230 VAC ±10%

–

Analogue input –
–
–
–
Built-in heat sink –
–
–
–
–


–
–

LED operation indicator 



Protective cover NA
NA
NA

3-phase loads via NA
3 single-phase SSRs
NA
NA

–
–
–
Load voltage/
current [VDC]
5 to 200 3 to 26.4
Input voltages
[VDC or VAC]
5 to 24 VDC –
12 to 24 VDC 12 VDC ±10%; 24 VDC ±10%
24 VAC  24 VAC/DC ±10%
Zero-cross 
Mounting
Features
Built-in varistor –
Replaceable –
power cartridge
Alarm output NA
NA
NA
–
Built-in failure detection NA
NA
NA
–
SSR open circuits detection NA
NA
NA
–
SSR short circuits detection NA
NA
NA
–
DIN-rail 
–
–

Screw –
–
–



–
Mounting socket 
Page 489
486
490
491
Solid state relays
Control panel mounting type
G3PA
G3PE
Power regulator
G3PE
G3PF
G3PW
G3ZA
Normal resistors
Middle and long wave
IR heater
Normal resistors
Normal resistors
Alloy heater
Pure metal heater, nonmetal
heater (Constant-current
models recommended.)
Depends on the SSR used
Distributes loop/control output
levels (mV%) to SSRs


–


Depends on the SSR used
–
–

–
–
Depends on the SSR used
–
–

–
–
Depends on the SSR used
Heater control
Heater control
Heater control
Heater control and diagnostics Single-phase power control
Intelligent power control
60 A
45 A
45 A
35 A
60 A
Depends on the SSR used

–
–
–
–
–
–









–
 400 to 480
–
–
–
–
–
–

–
–
–
–
–




–
–

–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
4 to 20 mA DC, 1 to 5 VDC
–





–





–

–
–
–
–
–











–


–
–
–
–

–
–
–
–
–
–
–
–



–
–
–



–
–
–
–


–
–
–







–







–
–
–
–
–
–
493
494
495
496
497
26
Solid state relays
Normal resistors
Middle and long wave IR
heater
Transformers and inductors

Standard

Available
– No/not available
NA Not applicable
487
488
G3RV
Panel mounted
The World's First Industrial Slim Relay
• G2RV compatible
• LED indicator built in SSR
• Push-in terminals and accessories for easy wiring
Ordering information
Zero
Input
cross
Rated voltage
function (operating voltage)
Output
Rated current
AC
50 Hz
DC
60Hz
Must operate Must release Rated load
voltage
voltage
voltage (load
voltage range)
Load current
Inrush current
Type of
Order code
connection
-
24 VAC/DC
10.7 mA 11.1 mA 4.3 mA
(21.6 to 26.4 VAC/DC)
21.6 V
1V
5 to 24 VDC
(3 to 26.4 VDC)
100 μA to 3 A
30 A
(60 Hz, 1 cycle)
Screw
G3RV-SL700-D AC/DC24
-
24 VAC/DC
10.7 mA 11.1 mA 4.3 mA
(21.6 to 26.4 VAC/DC)
21.6 V
1V
5 to 24 VDC
(3 to 26.4 VDC)
100 μA to 3 A
30 A
(60 Hz, 1 cycle)
Push-in
G3RV-SL500-D AC/DC24
Yes
24 VAC/DC
20 mA
(21.6 to 26.4 VAC/DC)
21 mA
11 mA
21.6 V
1V
100 to 240 VAC
(75 to 264 VAC)
0.1 A to 2 A
30 A
(60 Hz, 1 cycle)
Screw
G3RV-SL700-A AC/DC24
Yes
24 VAC/DC
20 mA
(21.6 to 26.4 VAC/DC)
21 mA
11 mA
21.6 V
1V
100 to 240 VAC
(75 to 264 VAC)
0.1 A to 2 A
30 A
(60 Hz, 1 cycle)
Push-in
G3RV-SL500-A AC/DC24
-
230 VAC
(207 to 253 VAC)
6.8 mA
8.1 mA
-
207 V
1V
5 to 24 VDC
(3 to 26.4 VDC)
100 μA to 3 A
30 A
(60 Hz, 1 cycle)
Screw
G3RV-SL700-D AC230
-
230 VAC
(207 to 253 VAC)
6.8 mA
8.1 mA
-
207 V
1V
5 to 24 VDC
(3 to 26.4 VDC)
100 μA to 3 A
30 A
(60 Hz, 1 cycle)
Push-in
G3RV-SL500-D AC230
Note: Ratings at an ambient temperature of 25°C
Accessories
Type
Description
Order code
Cross bar
2-pole
P2RVM-020_
Cross bar
3-pole
P2RVM-030_
Cross bar
4-pole
P2RVM-040_
Cross bar
10-pole
P2RVM-100_
Cross bar
20-pole
P2RVM-200_
PLC interface
Connect 8 relays and PLC output
P2RVC-8-O-F
Label
Plastic, for mounting on socket
R99-15 for G2RV
Label (Sticker)
Paper for mounting on socket or relay
R99-16 for G2RV
Separating plate
Provides isolation between adjacent relays to achieve 400 V isolation
P2RV-S
Solid state relays
Note: _ Select colour: R=Red, S=Blue, B=Black
Order code
G3RV-SL700/500-A
G3RV-SL700/500-D
Isolation
Triac
Mosfet
Output ON voltage drop
1.6 V rms max.
0.9 V max.
Leakage current
5 mA max. (at 200 VAC 50/60 Hz)
10 μA max. (at 24 VDC)
Operating indicator
Yes
Ambient temperature
Storage
-30~+100°C (with no icing or condensation)
Operating
-30~+55°C (with no icing or condensation)
26
Specifications
489
G3R-I/-O
Panel mounted
Compact SSR for I/O interface with high
dielectric strength requirements
High-speed models with optimum input ratings for a variety of sensors are available,
as well as input and output modules that can be used instead of the G2RS. Use a coupler conforming to VDE 0884 and assuring an I/O dielectric strength of 4,000V.
•
•
•
•
•
1.5 and 2A output current
5 to 200VDC/100 to 240VAC output voltages
Compatible with G2RS electromechanical relays
DIN-rail mounting via sockets
Operation indicator to confirm input
Ordering information
Input module
Response speed Input
–
Output
Rated voltage
Input current
(operating voltage)
Must operate
voltage
Must release
voltage
Logic level supply
voltage
Logic level supply
current
Size in mm (HxWxD) Order code
100 to 240 VAC
(60 to 264 VAC)
15 mA max.
60 VAC max.
20 VAC min.
4 to 32 VDC
0.1 to 100 mA
8 mA max.
4 VDC max.
1 VDC min.
6.6 VDC max.
3.6 VDC min.
29x13x28
G3R-IAZR1SN-UTU
(90.5x16x61
in combination with G3R-IDZR1SN-UTU
P2RF-05-E mounting
socket)
4 VDC max.
1 VDC min.
6.6 VDC max.
3.6 VDC min.
High-speed (1 kHz) 5 VDC
(4 to 6 VDC)
12 to 24 VDC
(6.6 to 32 VDC)
Low-speed (10 Hz) 5 VDC
(4 to 6 VDC)
12 to 24 VDC
(6.6 to 32 VDC)
G3R-IDZR1SN-1-UTU
Note: Ratings at an ambient temperature of 25°C
Output module
Zero cross
function
Input
Rated voltage
Input current
(operating voltage)
Must operate
voltage
Must release
voltage
Rated load voltage Load
Inrush
(load voltage range) current*1 current
Size in mm (HxWxD) Order code
Yes
5 to 24 VDC
(4 to 32 VDC)
4 VDC max.
1 VDC min.
100 to 240 VAC
(75 to 264 VAC)
0.05 to
2A
30 A
(60 Hz,
1 cycle)
5 to 48 VDC
(4 to 60 VDC)
0.01 to
2A
8A
(10 ms)
29x13x28
G3R-OA202SZN-UTU
(90.5x16x61
G3R-OA202SLN-UTU
in combination with
P2RF-05-E mounting G3R-ODX02SN-UTU
socket)
48 to 200 VDC
(40 to 200 VDC)
0.01 to
1.5 A
8A
(10 ms)
No
–
Output
15 mA max.
8 mA max.
–
G3R-OD201SN-UTU
Note: Ratings at an ambient temperature of 25°C
The minimum current value is measured at 10°C min.
*1
Socket & accessories
Order code
DIN rail
PCB
Screwless clamp
Screw
Soldering
Socket
Clip
Cross bar AC type
Cross bar DC type
Name plate
Socket
Socket
P2RF-05-S
P2CM-S
P2RM-SR
P2RM-SB
R99-11
P2RF-05-E
P2R-05P
Specifications
Input module
Output module
Order code
G3R-IAZR1SN-UTU G3R-IDZR1SN-UTU G3R-IDZR1SN-1UTU
G3R-OA202SZNUTU
Isolation
Photocoupler
Phototriac
Photocoupler
Operate time
20 ms max.
0.1 ms max.
15 ms max.
1/2 of load power
1 ms max.
source cycle + 1 ms
max.
1 ms max.
1 ms max.
Release time
20 ms max.
0.1 ms max.
15 ms max.
1/2 of load power source cycle + 1 ms max. 2 ms max.
2 ms max.
Response frequency
10 Hz
1 kHz
10 Hz
20 Hz
20 Hz
100 Hz
100 Hz
Output ON voltage drop
1.6 V max.
1.6 V max.
1.6 V max.
1.6 V max.
1.6 V max.
1.6 V max.
2.5 V max.
Leakage current
5 A max.
5 A max.
5 A max.
1.5 mA max.
1.5 mA max.
1 mA max.
1 mA max.
Operation indicator
Yes
Ambient temperature
Operating: -30 to 80°C (with no icing)
490
G3R-OA202SLNUTU
G3R-ODX02SN-UTU G3R-OD201SN-UTU
G3NA
Panel mounted
Hockey puck style SSR with 5-90 A
output currents
All models feature the same compact dimensions to provide a uniform mounting
pitch. A built-in varistor effectively absorbs external surges. The operation indicator
enables monitoring operation.
•
•
•
•
•
5-90 A output current
24-480 VAC/5-200VDC output voltages
Built-in varistor
Operation indicator (red LED)
Protective cover for greater safety
Ordering information
Applicable output load
Zero cross
function
Isolation
Rated input voltage Must operate
voltage
Must release
voltage
Load current with/without
heatsink at 40 °C
Order code
24 to 240 VAC
Yes
Phototriac
5 to 24 VDC
4 VDC max.
1 VDC min.
0.1 to 5 A/0.1 to 3 A
G3NA-205B-UTU DC5-24
Photocoupler
100 to 120 VAC
75 VAC max.
20 VAC min.
200 to 240 VAC
150 VAC max.
40 VAC min.
Phototriac
5 to 24 VDC
4 VDC max.
1 VDC min.
Photocoupler
100 to 120 VAC
75 VAC max.
20 VAC min.
200 to 240 VAC
150 VAC max.
40 VAC min.
Phototriac
5 to 24 VDC
4 VDC max.
1 VDC min.
Photocoupler
100 to 120 VAC
75 VAC max.
20 VAC min.
200 to 240 VAC
150 VAC max.
40 VAC min.
Phototriac
5 to 24 VDC
4 VDC max.
1 VDC min.
Photocoupler
100 to 120 VAC
75 VAC max.
20 VAC min.
200 to 240 VAC
150 VAC max.
40 VAC min.
Phototriac
5 to 24 VDC
4 VDC max.
1 VDC min.
Photocoupler
100 to 120 VAC
75 VAC max.
20 VAC min.
200 to 240 VAC
150 VAC max.
40 VAC min.
Phototriac
5 to 24 VDC
4 VDC max.
1 VDC min.
Photocoupler
100 to 240 VAC
75 VAC max.
20 VAC min.
Phototriac
5 to 24 VDC
4 VDC max.
1 VDC min.
Photocoupler
100 to 240 VAC
75 VAC max.
20 VAC min.
Photocoupler
5 to 24 VDC
4 VDC max.
1 VDC min.
100 to 240 VAC
75 VAC max.
20 VAC min.
5 to 24 VDC
4 VDC max.
1 VDC min.
100 to 240 VAC
75 VAC max.
20 VAC min.
5 to 24 VDC
4 VDC max.
1 VDC min.
100 to 240 VAC
75 VAC max.
20 VAC min.
5 to 24 VDC
4 VDC max.
1 VDC min.
100 to 240 VAC
75 VAC max.
20 VAC min.
5 to 24 VDC
4 VDC max.
1 VDC min.
100 to 240 VAC
75 VAC max.
20 VAC min.
5 to 24 VDC
4 VDC max.
1 VDC min.
100 to 240 VAC
75 VAC max.
20 VAC min.
20 A
40 A
50 A
75 A
90 A
5 to 200 VDC
200 to 480 VAC
10 A
10 A
25 A
50 A
75 A
90 A
No
Yes
G3NA-205B-UTU AC200-240
0.1 to 10 A/0.1 to 4 A
G3NA-210B-UTU DC5-24
G3NA-210B-UTU AC100-120
G3NA-210B-UTU AC200-240
0.1 to 20 A/0.1 to 4 A
G3NA-220B-UTU DC5-24
G3NA-220B-UTU AC100-120
G3NA-220B-UTU AC200-240
0.1 to 40 A/0.1 to 6 A
G3NA-240B-UTU DC5-24
G3NA-240B-UTU AC100-120
G3NA-240B-UTU AC200-240
0.1 to 50 A/0.1 to 6 A
G3NA-250B-UTU DC5-24
G3NA-250B-UTU AC100-120
G3NA-250B-UTU AC200-240
1 to 75 A/1 to 7 A
G3NA-275B-UTU DC5-24
G3NA-275B-UTU AC100-240
1 to 90 A/1 to 7 A
G3NA-290B-UTU DC5-24
G3NA-290B-UTU AC100-240
0.1 to 10 A/0.1 to 4 A
G3NA-D210B-UTU DC5-24
G3NA-D210B-UTU AC100-240
0.2 to 10 A/0.2 to 4 A
G3NA-410B-UTU DC5-24
G3NA-410B-UTU AC100-240
0.2 to 20 A/0.2 to 4 A
G3NA-425B-UTU DC5-24
G3NA-425B-UTU AC100-240
0.2 to 40 A/0.2 to 6 A
G3NA-450B-UTU DC5-24
G3NA-450B-UTU AC100-240
1 to 75 A/1 to 7 A
G3NA-475B-UTU DC5-24
Solid state relays
10 A
G3NA-205B-UTU AC100-120
G3NA-475B-UTU AC100-240
1 to 90 A/1 to 7 A
G3NA-490B-UTU DC5-24
G3NA-490B-UTU AC100-240
26
5A
491
G3NA
Panel mounted
Accessories
Name
Applicable SSRs
Order code
One-touch mounting plates
–
R99-12 FOR G3NA
Mounting bracket
G3NA-240B-UTU
R99-11 FOR G3NA
Slim models enabling DIN-rail mounting
G3NA-205B-UTU, G3NA-210B-UTU,
G3NA-D210B-UTU, G3NA-410B-UTU
Y92B-N50
G3NA-225B-UTU, G3NA-440B-UTU
Y92B-N100
G3NA-240B-UTU, G3NA-440B-UTU
Y92B-N150
G3NA-450B-UTU
Y92B-P250
G3NA-275B-UTU, G3NA-290B-UTU,
G3NA-475B-UTU, G3NA-490B-UTU
Y92B-P250NF
G3NA-205B-UTU, G3NA-210B-UTU,
G3NA-D210B-UTU, G3NA-220B-UTU,
G3NA-410B-UTU, G3NA-425B-UTU
Y92B-A100
G3NA-240B-UTU, G3NA-440B-UTU
Y92B-A150N
G3NA-450B-UTU
Y92B-A250
Slim models enabling DIN-rail mounting
Low-cost models
Specifications
Operating voltage range
5 to 24 VDC: 4 to 32 VDC
100 to 120 VAC: 75 to 132 VAC
200 to 240 VAC: 150 to 264 VAC
Output ON voltage drop
G3NA-2: 1.6 V (RMS) max.
G3NA-4: 1.8 V (RMS) max.
G3NA-D2: 1.5 V max.
Leakage current
5 mA (100 V)/10 mA (200 V)
G3NA-D2: 5 mA max. (200 VDC)
Load voltage range
200 to 480 VAC: 180 to 528 VAC
24 to 240 VAC: 19 to 264 VAC
5 to 200 VDC: 4 to 220 VDC
Ambient temperature
Operating: -30 to 80°C
Operate & release time
1/2 of load power source cycle + 1 ms max. (DC input)
1/2 of load power source cycle + 1 ms max. (DC input)
G3NA-D2
1 ms max. (DC input; release 5 ms),
30 ms max. (AC input)
Size in mm (HxWxD)
58x43x27
492
G3PA
Panel mounted
Solid State Relays with exchangeable
power cartridge
Optimum design of the heat sink has contributed to the downsizing of this product.
The power element cartridges of G3PA are easily replaceable for easy maintenance.
G3PA can be mounted on a DIN-rail or using screws.
•
•
•
•
10-60 A output current
24-480 VAC output voltages
Applicable with 3-phase loads
Replaceable power element cartridges
Ordering information
Rated output load
24 to 240 VAC
10 A
Zero cross
function
Rated input
voltage
Operating
voltage range
Input
current
impedance
Voltage level
Must operate
voltage
Must release
voltage
Yes
5 to 24 VDC
4 to 30 VDC
7 mA max.
4 VDC max.
1 VDC min.
100x27x100
G3PA-210B-VD DC5-24
100x37x100
G3PA-220B-VD DC5-24
40 A
100x47x100
G3PA-240B-VD DC5-24
60 A
100x110x100
G3PA-260B-VD DC5-24
100x27x100
G3PA-210B-VD AC24
20 A
100x37x100
G3PA-220B-VD AC24
40 A
100x47x100
G3PA-240B-VD AC24
60 A
100x110x100
G3PA-260B-VD AC24
100x37x100
G3PA-420B-VD DC12-24
30 A
100x47x100
G3PA-430B-VD DC12-24
20 A
100x37x100
G3PA-420B-VD-2 DC12-24
30 A
100x47x100
G3PA-430B-VD-2 DC12-24
50 A
100x110x100
G3PA-450B-VD-2 DC12-24
24 VAC
20 A
200 to 480 VAC
Order code
20 A
10 A
180 to 400 VAC
Size in mm
(HxWxD)
12 to 24 VDC
19.2 to 26.4 VAC 1.4 k ±20%
9.6 to 30 VDC
7 mA max.
19.2 VAC max.
9.2 VDC max.
4.8 VAC min.
1 VDC min.
Accessories
G32A-D_ _ enables 2 line switching of 3 phase configurations
Load voltage
range
Carry
Applicable SSR
current
Order code
19 to 264 VAC
10 A
G3PA-210B-VD DC5-24
G32A-A10-VD DC5-24
G3PA-210B-VD AC24
G32A-A10-VD AC24
G3PA-220B-VD DC5-24
G32A-A20-VD DC5-24
30 A
G3PA-220B-VD AC24
G32A-A20-VD AC24
40 A
G3PA-240B-VD DC5-24
G32A-A40-VD DC5-24
G3PA-240B-VD AC24
G32A-A40-VD AC24
G3PA-260B-VD DC5-24
G32A-A60-VD DC5-24
G3PA-260B-VD AC24
G32A-A60-VD AC24
150 to 440 VAC 20 A
G3PA-420B-VD DC12-24
G32A-A420-VD DC12-24
30 A
G3PA-430B-VD DC12-24
G32A-A430-VD DC12-24
180 to 528 VAC 20 A
G3PA-420B-VD-2 DC12-24
G32A-A420-VD-2 DC12-24
30 A
G3PA-430B-VD-2 DC12-24
G32A-A430-VD-2 DC12-24
50 A
G3PA-450B-VD-2 DC12-24
G32A-A450-VD-2 DC12-24
20 A
40 A
60 A
Current flow
Applicable SSR
10 A
G3PA-210B-VD, G3PA-210BL-VD, G32A-D20
G3PA-220B-VD, G3PA-220BL-VD,
G3PA-420B-VD, G3PA-420B-VD-2
20 A
Order code
G3PA-430B-VD, G3PA-430B-VD-2, G32A-D40
G3PA-240B-VD, G3PA-240BL-VD
Solid state relays
Replacement parts: Power device cartridges
Isolation
Phototriac coupler
Indicator
Yes
Ambient temperature
Operating: -30 to 80°C
Load voltage range
200 to 480 VAC: 180 to 528 VAC
24 to 240 VAC: 19 to 264 VAC
180 to 400 VAC: 150 to 440 VAC
Output ON drop
1.6 V (RMS) max.
Operate time
0.5 of load power source cycle + 1 ms max. (DC input, -B models)
1.5 of load power source cycle + 1 ms max. (AC input)
1 ms max. (-BL models)
Release time
0.5 of load power source cycle + 1 ms max. (DC input)
1.5 of load power source cycle + 1 ms max. (AC input)
26
Specifications
493
G3PE
Panel mounted
Omron’s G3PE compact industrial SSR with
outstanding surge endurance
The G3PE features an original surge-pass circuit that gives outstanding surge endurance and protects the semiconductor device against voltages in excess of 30 kV.
•
•
•
•
•
•
Single and three phase, 15-45 A output current
100-240 VAC and 200-480 VAC output voltages
Models available without zero cross
Improved surge dielectric strength for output circuits
Terminal cover with finger protection
Mount to DIN track or with screws
Ordering information
Phases Rated voltage
(operating voltage)
Rated output Permissible I2t
load
(half 60 Hz wave)
Applicable heater capacity
AC1: resistive load)
Size in mm (HxWxD)
Number of poles
Order code
1
15 A (at 40°C) 121 A2s
3 kW (at 200 VAC)
100x22.5x100
1
G3PE-215B DC12-24
25 A (at 40°C) 260 A2s
5 kW (at 200 VAC)
1
G3PE-225B DC12-24
1
G3PE-235B DC12-24
1
G3PE-245B DC12-24
1
G3PE-515B DC12-24
1
G3PE-525B DC12-24
1
G3PE-535B DC12-24
1
G3PE-545B DC12-24
3
G3PE-515B-3N DC12-24
100 to 240 VAC
(75 to 264 VAC)
35 A
200 to 480 VAC
(180 to 528 VAC)
200 to 480 VAC
(180 to 528 VAC)
7 kW (at 200 VAC)
45 A
9 kW (at 200 VAC)
15 A (at 40°C) 128 A2s
6 kW (at 400 VAC)
25 A (at 40°C) 1,350 A2s
10 kW (at 400 VAC)
35 A
14 kW (at 400 VAC)
45 A
3
1,260 A2s
6,600 A2s
100x44.5x100
100x22.5x100
100x44.5x100
18 kW (at 400 VAC)
15 A (at 40°C) 260 A2s
12.5 kW (at 480 VAC)
100x80x155
2
G3PE-515B-2N DC12-24
25 A (at 40°C)
20.7 kW (at 480 VAC)
120x80x155
3
G3PE-525B-3N DC12-24
100x80x155
2
G3PE-525B-2N DC12-24
140x80x155
3
G3PE-535B-3N DC12-24
120x80x155
2
G3PE-535B-2N DC12-24
140x110x155
3
G3PE-545B-3N DC12-24
140x80x155
2
G3PE-545B-2N DC12-24
35 A
1,260 A2s
45 A
29 kW (at 480 VAC)
37.4 kW (at 480 VAC)
Specifications
Rated input voltage
12 to 24 VDC
Operating voltage range
9.6 to 30 VDC
Rated input current (impedance)
7 mA max. (zero cross models); 15 mA max. (models without zero cross)
Zero cross function
Yes
Must operate voltage
9.6 VDC max.
Must release voltage
1 VDC min.
Isolation method
Phototriac coupler
Operation indicator
Yes (yellow)
Load voltage range
200 to 480 VAC models: 180 to 528 VAC
100 to 240 VAC models: 75 to 264 VAC
Operate time
1/2 of load power source cycle +1 ms max.
Release time
1/2 of load power source cycle +1 ms max.
Leakage current
10 mA (at 200 VAC)
Ambient temperature
Operating: -30 to 80°C
494
G3PF
Panel mounted
“Intelligent” SSR with Built-in current
transformer which enables Heater Burnout
and SSR Shortcircuit Failure Detection.
•
•
•
•
•
•
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Three types of input terminals available: M3 terminals, screwless clamp terminals
(detachable), or compact slotted screw terminals (detachable).
• Zero cross function.
• Operation indicator.
Ordering information
Applicable output load (See note.)
Input terminals
Alarm output
100 to 240 VAC
M3 terminals
G3PF-225B
2 to 35 A
1 output (Heater Burnout Detection,
100x45x110
SSR Short-circuit Failure Detection, Common) 100x55x130
2 to 25 A
100x45x110
G3PF-525B
2 to 35 A
100x55x130
G3PF-535B
100x45x117
G3PF-225B-CTB
100x55x137
G3PF-235B-CTB
2 to 25 A
100x45x117
G3PF-525B-CTB
2 to 35 A
100x55x137
G3PF-535B-CTB
2 to 25 A
200 to 480 VAC
100 to 240 VAC
2 to 25 A
2 to 35 A
200 to 480 VAC
Size in mm (HxWxD)
Screwless clamp terminals (detachable) 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection)
Model
G3PF-235B
Note: The load current depends on the ambient temperature. Refer to datasheet for details.
Specifications
Order code
G3PF-225B
Rated load voltage
100 to 240 VAC (50/60 Hz)
Operating voltage range
75 to 264 VAC, 50/60 Hz
Applicable load current*1
25 A (at 40°C)
Minimum load current
2A
Inrush current resistance
220 A (60 Hz, 1 cycle)
Operate time
1/2 of load power source cycle + 1 ms max.
Release time
Alarm output
G3PF-525B
180 to 528 VAC, 50/60 Hz
35 A (at 40°C)
25 A (at 40°C)
35 A (at 40°C)
430 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
430 A (60 Hz, 1 cycle)
1/2 of load power source cycle + 1 ms max.
Output ON voltage drop 1.6 V (RMS) max.
1.8 V (RMS) max.
Leakage current
20 mA max. (at 480 VAC)
10 mA max. (at 200 VAC)
Output ON voltage drop 1.5 V max.
Leakage current
1 mA max.
Isolation resistance
100 M min. (at 500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min.
Vibration resistance
Destruction: 10 to 55 to10 Hz, 0,35-mm single amplitude (0,7-mm double amplitude)
Shock resistance
Destruction: 294 m/s²
Ambient storage temperature
-30 to 70°C (with no icing or condensation)
Ambient operating temperature
-20 to 60°C (with no icing or condensation)
Ambient operating humidity
45% to 85%
Weight
Approx. 400 g
Approx. 630 g
Approx. 400 g
Approx. 630 g
The load current depends on the ambient temperature.
26
*1
G3PF-535
200 to 480 VAC (50/60 Hz)
Solid state relays
Main circuit
G3PF-235B
495
G3PW
Power controller
Thyristor type single-phase power controller
that enables precise temperature control
Compact and the possibility for side-by-side mounting for multiple units are the basics for this new generation of power controllers. Process value can be easily monitored via the 7-segment display on the front panel.
•
•
•
•
•
Precise heater burnout detection
Phase control or optimum cycle control
RS-485 communications to set manipulated variables and monitor load current
Total runtime monitoring
Application with various loads: constant load resistance, variable load resistance
Ordering information
Applicable output load
Type
Contact terminal block
100 to 240 VAC
Standard
Screwless clamp terminal block No
20 A
Heater burnout detection
Communications
Order code
No
G3PW-A220EU-C
45 A
G3PW-A245EU-C
60 A
20 A
G3PW-A260EU-C
Constant current
Yes
Yes
45 A
G3PW-A245EC-C-FLK
60 A
20 A
G3PW-A260EC-C-FLK
Standard
45 A
Terminal block with small slot- No
ted screws
No
G3PW-A220EU-S
G3PW-A245EU-S
60 A
20 A
G3PW-A220EC-C-FLK
G3PW-A260EU-S
Constant current
Yes
Yes
G3PW-A220EC-S-FLK
45 A
G3PW-A245EC-S-FLK
60 A
G3PW-A260EC-S-FLK
Accessories (Order separately)
Name
Resistive value
Display
Model
External Variable Resistor
2 k
202
G32X-V2K
Specifications
Order code
Standard Models
Constant-current Models
G3PW-A2__EU-_
G3PW-A2__EC-__-FLK
Control method
Analogue input: Phase control or optimum cycle control
Voltage ON/OFF input: ON/OFF control
Maximum load capacity
Phase control: Linear (resistive) load, transformer primary-side control (flux density: 1.25 T max.)
Optimum cycle control: Linear (resistive) load (Transformer primaryside control is not supported.)
Output mode Analogue input
Phase control
Proportional to phase angle (same as G3PX), proportional to Proportional to phase angle (same as G3PX), proportional to
square voltage, proportional to voltage
square voltage, proportional to voltage, constant-current control
Optimum cycle
control
Optimum cycle control (Output is switched to 100% or 0% each half cycle.)
Voltage ON/OFF input ON/OFF control
496
Proportional to voltage control
G3ZA
Power controller
Multi-channel power controller
for smarter SSR usage
The G3ZA receives manipulated variables generated by control loops or manual
settings via a simple-to-wire RS-485. It regulates the heater power with high
precision by driving up to eight standard SSRs. Moreover, the offset control reduces
peak power in the supply net.
•
•
•
•
•
Multi-channel power controller
Controls up to eight standard solid state relays
Easy integration with PLC
Compact size
Available with heater alarms (four channels) or without (eight channels)
Ordering information
Name
Number of control channels
Heater alarm
Load power supply voltage
Order code
Multi-channel power controller
4
Supported
100 to 240 VAC
G3ZA-4H203-FLK-UTU
400 to 480 VAC
G3ZA-4H403-FLK-UTU
100 to 240 VAC
G3ZA-8A203-FLK-UTU
400 to 480 VAC
G3ZA-8A403-FLK-UTU
8
Not supported
Accessories
Name
Hole diameter
Order code
Current transformer (CT)
5.8 dia.
E54-CT1
12.0 dia.
E54-CT3
Specifications
Item
Load power supply voltage range
100 to 240 VAC
Serial Communications Unit (RS-485)
Programmable Controller
400 to 480 VAC
Power supply voltage
100 to 240 VAC (50/60 Hz)
Operating voltage range
85 to 264 VAC
Power consumption
16 VA max.
Load power supply voltage
100 to 240 VAC
400 to 480 VAC
Load power supply voltage range
75 to 264 VAC
340 to 528 VAC
Manipulated variable input
0.0 to 100.0% (via RS-485 communications)
Current transformer input
Single-phase AC, 0 to 50 A (primary current of CT)
Trigger output
One voltage output for each channel, 12 VDC ±15%, max. load current: 21 mA
(with built-in short-circuit protection circuit)
Alarm output
NPN open collector, one output
Max. applicable voltage: 30 VDC
Max. load current: 50 mA
Residual voltage: 1.5 V max.
Leakage current: 0.4 mA max.
RS-485 commands
READY
SD/RD
SW1
LED indicators
Ambient operating temperature
-10 to 55°C (with no icing or condensation)
Ambient operating humidity
25 to 85%
Storage temperature
-25 to 65°C (with no icing or condensation)
SW2
ERROR
G3ZA-8
SSR
Multi-channel
Power Controller
SSR
SSR
SSR
8 total
Solid state relays
Indications
OCC
Current indication accuracy
±3 A (for models with heater burnout detection)
Insulation resistance
100 Mmin. (at 500 VDC) between primary and secondary
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between primary and secondary
Vibration resistance
Vibration frequency: 10 to 55 Hz, acceleration: 50 m/s2 in X, Y, and Z directions
Shock resistance
300 m/s2 three times each in six directions along three axes
Weight
Approx. 200 g (including terminal cover)
Degree of protection
IP20
Memory protection
EEPROM (non-volatile memory) (number of writes: 100,000)
Installation environment
Overvoltage category III, pollution degree 2 (according to IEC 60664-1)
Approved standards
UL508 (Listing), CSA22.2 No. 14
EN50178
EN61000-6-4 (EN55011: 1998, A1: 1999 Class A, Group 1)
EN61000-6-2: 2001
Size in mm (HxWxD)
76x45x111
26
Performance
1/5th ON (20%)
Manipulated
variable: 20%
Optimum cycle control
• Optimum cycle control is performed by driving SSRs according to load power detection and trigger signals. (Zero-cross SSRs are used.)
• Noise is suppressed while ensure high-speed response by turning outputs ON and OFF each half cycle to achieve high-precision temperature control.
497
Low voltage switchgear
DIRECT CONTROL DC CONTACTOR
J7KNG – Low-power consumption DC contactors
Now it is possible to control contactors directly from a PLC with electronic output.
Our new J7KNG models consume only 3 W inrush/sealed power up to 22 A contactors
and 4 W inrush/sealed power up to 40 A contactors!
• Low inrush & sealed control circuits
• Control terminals on both sides
• Wide range up to 22 A with built-in auxiliary contact and up to 40 A
Which type of application is required?
Control switches
Motor switching
Current rating required?
Low
up to 12 A, 5.5 kW
High
up to 210 A, 132 kW
Mini contactor
relays
(10 A)
Mini motor
contactor
Motor contactor
J7KNA-AR
J7KNA
J7KN
Page 503
498
Page 505
Page 506
Motor protection
Fuseless
Thermal overload
relays
(0.12 to 220 A)
Motor protection
circuit breakers
(0.12 to 220 A)
J7TKN
J7MN
Page 508
Page 510
27
Protection
with fuse
Low voltage switchgear
Which kind of protection is needed?
499
Selection table
Motor protection circuit breaker
MPCB
Category
Type
Setting range current
Number of ranges
Auxiliary contact external
J7MN-3P/3R
0.16 - 32 A
16
front 1 NO and 1 NC or 2 NO,
side 1 NO and NC or 2 NO or 2 NC
510
Page
Contactors
Category
Auxiliary contacts
Type
Maximum power
AC3-380/415 V
Rated current
AC3-380/415 V
Main contacts
Included
External
Page
Contactors
–
J7KNA-AR
J7KNA-09/12
4 kW or 5 kW
J7KN(G)-10
4 kW
J7KN(G)-14
5.5 kW
J7KN(G)-18
7.5 kW
J7KN(G)-22
11 kW
10 A th
9/12 A
10 A
14 A
18 A
22 A
4 in 4 configurations
3 or 4
–
1
4 in different combinations
503
505
3 or 4
1 NO or 1 NC
4 contacts*1
506
Thermal overload
Category
*1
Type
Setting range D.O.L.
Number of ranges
Auxiliary contacts included
Page
Using J7KN-*D double wiring coils 1 aux. less
500
506
Thermal overload
J7TKN-A
0.12 - 14 A
13
1 NO and 1 NC
508
J7TKN-B
0.12 - 32 A
16
1 NO and 1 NC
508
Low voltage switchgear
Motor protection circuit breaker
J7MN-6R
Over lapping area
J7MN-3P/3R
J7MN-6R
J7MN-9R
26 - 63 A
5
63 - 100 A
4
front 1 NO and 1 NC or 2 NO,
side 1 NO and NC or 2 NO or 2 NC
510
Contactors
J7KN(G)-24
11 kW
J7KN(G)-32
15 kW
J7KN(G)-40
18.5 kW
22 kW
30 kW
37 kW
45 kW
J7KN-110
55 kW
24 A
32 A
40 A
50 A
62 A
74 A
85 A
110 A
3
–
front and side 8-contacts*1
506
J7KN-50
J7KN-62
3
–
front and side 8-contacts*1
506
J7KN-74
J7KN-85
3
2 NO and 2 NC
–
506
Thermal overload
J7TKN-C
28 - 42 A
1
1 NO and 1 NC
508
J7TKN-E
60 - 120 A
2
1 NO and 1 NC
508
Low voltage switchgear
Using J7KN-*D double wiring coils 1 aux. less
27
*1
J7TKN-D
40 - 74 A
3
1 NO and 1 NC
508
501
Selection table
Motor protection circuit breaker
MPCB
Category
Type
Setting range current
Number of ranges
Auxiliary contact external
Page
Contactors
Category
Auxiliary contacts
Type
Maximum power
AC3-380/415 V
Rated current
AC3-380/415 V
Main contacts
Included
External
Page
Contactors
J7KN-151
Thermal overload
502
J7KN-200
90 kW
110 kW
150 A
175 A
200 A
3 or 4
–
front and side 8-contacts*1
506
Category
Type
Setting range D.O.L.
Number of ranges
Auxiliary contacts included
Page
J7KN-176
75 kW
3
2 NO and 1 NC
2 NO and 2 NC
Thermal overload
J7TKN-E
60 - 120 A
2
1 NO and 1 NC
508
J7TKN-F
100 - 220 A
2
1 NO and 1 NC
J7KNA-AR
Mini contactor relays
Main mini contactor relay, 4-pole
Three basic units can be combined with different additional auxiliary contacts.
4-pole, 6-pole and 8-pole versions in different configurations are possible as well as
different coil voltages (AC and DC). Accessories such as suppressors are available.
•
•
•
•
•
Mirror contacts
Screw fixing and snap fitting (35 mm DIN-rail)
Rated current = 10 A (Ith)
Suitable for electronic devices (DIN 19240)
Finger proof (BGV A2)
Ordering information
Operation
Contacts
NO
NC
Distinctive number
according to
DIN EN 50011
Ratings
AC15
230 V
A
400 V
A
Ith, A
Coil voltage *1,
replace _ _ _ with:
Thermal rated Order code
current
4-pole, with screw terminals
AC
DC solenoid
DC solenoid
with diode
*1
VAC
VDC
4
0
40 E
3
2
10
J7KNA-AR-40_ _ _
24
110
230
–
–
3
1
31 E
3
2
10
J7KNA-AR-31 _ _ _
24
110
230
–
–
2
2
22 E
3
2
10
J7KNA-AR-22 _ _ _
24
110
230
–
–
4
0
40 E
3
2
10
J7KNA-AR-40 _ _ _
–
–
–
24D
110D
3
1
31 E
3
2
10
J7KNA-AR-31 _ _ _
–
–
–
24D
110D
2
2
22 E
3
2
10
J7KNA-AR-22 _ _ _
–
–
–
24D
110D
4
0
40 E
3
2
10
J7KNA-AR-40 _ _ _ _
–
–
–
24VS
–
3
1
31 E
3
2
10
J7KNA-AR-31 _ _ _ _
–
–
–
24VS
–
2
2
22 E
3
2
10
J7KNA-AR-22 _ _ _ _
–
–
–
24VS
–
Other coil voltages available on request
Accessories
Contacts
NO
NC
Ratings
Thermal rated current
AC15
230 V
A
Ith, A
400 V
A
Order code
1
1
3
2
10
J73KN-A-11
0
2
3
2
10
J73KN-A-02
4
0
3
2
10
J73KN-A-40
2
2
3
2
10
J73KN-A-22
0
4
3
2
10
J73KN-A-04
Voltage marking at the coil for
Rated control voltage Us range for
50 Hz
60 Hz
50 Hz
V
V
min. V
max. V
min. V
max. V
24
24
24
22
24
24
24
110
110 to 115
120 to 125
110
115
120
125
230
220 to 230
240
220
230
240
250
Size in mm (HxWxD)
57.5x45x49
60 Hz
27
Suffix to contactor type
e.g. J7KNA-09-10-24
Low voltage switchgear
Specifications
503
504
J7KNA
Mini motor contactors
Motor contactors from 4 to 5.5 kW for normal
duty switching
This modular system consists of main contactors and additional contact blocks.
The basic units can be combined with auxiliary contacts (top mounting).
Reversed versions, including integrated mechanical interlock, are available as well
as 3-main-pole and 4-main-pole versions.
•
•
•
•
•
4 kW and 5.5 kW versions are available
Different coil voltages (AC and DC)
Mini and normal-size versions are available
The contactors can be mounted with screw fixing and snap fitting on a DIN-rail
All components are finger proof
Ordering information
Operation
AC/DC
solenoid
Poles
3
Rating AC2, AC3
380 V
400 V
415 V
kW
4
5.5
DC solenoid
with diode
DC solenoid
with diode
*1
AC3
AC1
500 V
kW
660 V
690 V
kW
400 V
A
690 V
A
NO
NC
4
4
9
20
1
0
J7TKN-A
0
1
J7TKN-A
J7KNA-09-01_ _ _
24
110
230
400
24D
1
0
J7TKN-A
J7KNA-12-10_ _ _
24
110
230
400
24D
0
1
J7TKN-A
J7KNA-12-01_ _ _
24
110
230
400
24D
5.5
12
20
Overload
relay
Size in mm
(HxWxD)
Order code
57.5x45x49
J7KNA-09-10_ _ _
24
110
230
400
24D
VAC
VDC
4
4
4
4
9
20
0
0
J7TKN-A
J7KNA-09-4_ _ _
24
110
230
400
24D
3
4
4
4
9
20
1
0
J7TKN-A
J7KNA-09-10_ _ _
–
–
–
–
24VS
0
1
J7TKN-A
J7KNA-09-01_ _ _
–
–
–
–
24VS
1
0
J7TKN-A
J7KNA-12-10_ _ _
–
–
–
–
24VS
0
1
J7TKN-A
J7KNA-12-01_ _ _
–
–
–
–
24VS
J7KNA-09-01 R_ _ _
24
110
230
400
24D
5.5
AC/DC
solenoid
Coil voltage *1 ,
replace _ _ _ with:
Auxiliary
contact
5.5
Rated current
3
reversing
contactors
5.5
5.5
12
20
4
4
4
9
20
0
1
J7TKN-A
57.5x94.5x50
5.5
5.5
5.5
12
20
0
1
J7TKN-A
J7KNA-12-01 R_ _ _
24
110
230
400
24D
4
4
4
9
20
0
1
J7TKN-A
J7KNA-09-01 R_ _ _
–
–
–
–
24VS
5.5
5.5
5.5
12
20
0
1
J7TKN-A
J7KNA-12-01 R_ _ _
–
–
–
–
24VS
Other coil voltages available on request
Accessories
Auxiliary contacts
Rated current
NO
NC
AC15
230 V
Order code
400 V
1
1
3A
2A
J73KN-AM-11
0
2
3A
2A
J73KN-AM-02
2
2
3A
2A
J73KN-AM-22
Low voltage switchgear
Contacts
Auxiliary contacts for reversing contactors
1
1
3A
2A
J73KN-AM-11V
1
1
3A
2A
J73KN-AM-11X
Link modules between MPCB & contactors
For MPCB J7MN-3P/J7MN-3R
J77MN-VKA-3
Insulated wiring system for J7KNA
Reversing or parallel contactors
J75-WK11
Star-delta combination
J75-WK12
27
Specifications
Suffix to contactor type e.g. Voltage marking
J7KNA-09-10-24
at the coil for
Rated control voltage Us
range for
Main contacts
J7KNA-09-_ _ _
J7KNA-12-_ _ _
Rated insulation voltage Ui
690 VAC
690 VAC
Making capacity Ieff
at Ue = 690 VAC
165 A
165 A
Breaking
capacity Ieff
cos = 0,65
400 VAC
100 A
100 A
500 VAC
90 A
90 A
690 VAC
80 A
80 A
Mechanical life AC operated
5×106
5×106
DC operated
15×106
15×106
96 A
120 A
50 Hz
60 Hz
50 Hz
V
V
min. V
max. V
min. V
max. V
24
24
24
22
24
24
24
110
110 to
115
120 to
125
110
115
120
125
220 to
230
240
220
230
60 Hz
230
240
250
Short time current
10 s current
505
J7KN
Motor contactors
Motor contactors from 4-110 kW for normal
and heavy-duty switching
This modular system consists of main contactors and additional contact blocks.
The basic units can be combined with auxiliary contacts. DC-DC versions, integrated
mechanical interlock, are available as well as 3-main-pole and 4-main-pole versions.
•
•
•
•
Basic units can be combined with auxiliary contacts (top/side mounting)
3-main-pole and 4-main-pole versions are possible
The power range covers 4 to 110 kW
Different coil voltages (AC and DC)
Ordering information
Operation
AC/DC
Poles
3
AC3
400 V
rated
motor
current
NC
4
5.5
5.5
25
1
0
J7KN-10-10_ _ _
24
110 230
400
24D
110D
4
5.5
5.5
25
0
1
J7KN-10-01_ _ _
24
110 230
400
24D
110D
5.5
7.5
7.5
25
1
0
J7KN-14-10_ _ _
24
110 230
400
24D
110D
5.5
7.5
7.5
25
0
1
J7KN-14-01_ _ _
24
110 230
400
24D
110D
7.5
10
10
32
1
0
J7KN-18-10_ _ _
24
110 230
400
24D
110D
7.5
10
10
32
0
1
J7KN-18-01_ _ _
24
110 230
400
24D
110D
11
10
10
32
1
0
J7KN-22-10_ _ _
24
110 230
400
24D
110D
11
10
10
32
0
1
J7KN-22-01_ _ _
24
110 230
400
24D
110D
24 A
11
15
15
50
0
0
J7KN-24_ _ _
24
110 230
400
24D
110D
32 A
15
18.5
18.5
65
0
0
J7KN-32_ _ _
24
110 230
400
24D
110D
40 A
18.5
18.5
18.5
80
0
0
J7KN-40_ _ _
24
110 230
400
24D
110D
50 A
22
30
30
110
0
0
J7KN-50_ _ _
24
110 230
400
24D
110D
62 A
30
37
37
120
0
0
J7KN-62_ _ _
24
110 230
400
24D
110D
74 A
37
45
45
130
0
0
J7KN-74_ _ _
24
110 230
400
24D
110D
85 A
45
55
55
150
2
2
J7KN-85-22_ _ _
24
110 230
400
–
–
J7KN-85-21_ _ _
–
–
–
24D
110D
J7KN-110-22_ _ _
24
110 230
400
–
–
J7KN-110-21_ _ _
–
–
–
–
24D
110D
J7KNG-10-10_ _ _
–
–
–
–
24D
110D
10 A
10 A
55
75
55
170
VAC
2
J7TKN-B
J7TKN-C
J7TKN-D
J7TKN-E
67x45x82.5
78x45x104.5
112x60x113
134x90x119
2
5.5
25
1
0
4
5.5
5.5
25
0
1
J7KNG-10-01_ _ _
–
–
–
–
24D
110D
5.5
7.5
7.5
25
1
0
J7KNG-14-10_ _ _
–
–
–
–
24D
110D
5.5
7.5
7.5
25
0
1
J7KNG-14-01_ _ _
–
–
–
–
24D
110D
7.5
10
10
32
1
0
J7KNG-18-10_ _ _
–
–
–
–
24D
110D
7.5
10
10
32
0
1
J7KNG-18-01_ _ _
–
–
–
–
24D
110D
11
10
10
32
1
0
J7KNG-22-10_ _ _
–
–
–
–
24D
110D
11
10
10
32
0
1
J7KNG-22-01_ _ _
–
–
–
–
24D
110D
24 A
11
15
15
50
0
0
J7KNG-24_ _ _
–
–
–
–
24D
110D
32 A
15
18.5
18.5
65
0
0
J7KNG-32_ _ _
–
–
–
–
24D
110D
40 A
18.5
18.5
18.5
80
0
0
J7KNG-40_ _ _
–
–
–
–
24D
110D
150 A
75
75
75
230
0
0
J7KN-151_ _ _
24
110 230
400
24
110
175 A
90
90
90
250
0
0
J7KN-176_ _ _
24
110 230
400
24
110
200 A
110
132
132
350
2
2
202x130x190
J7KN-200-21_ _ _
24
110 230
400
24
110
10 A
4
5.5
5.5
25
1
0
67x45x82.5
J7KN-10-10_ _ _ VKN-3
24
110 230
400
24D
110D
4
5.5
5.5
25
0
1
J7KN-10-01_ _ _ VKN-3
24
110 230
400
24D
110D
5.5
7.5
7.5
25
1
0
J7KN-14-10_ _ _ VKN-3
24
110 230
400
24D
110D
5.5
7.5
7.5
25
0
1
J7KN-14-01_ _ _ VKN-3
24
110 230
400
24D
110D
7.5
10
10
32
1
0
J7KN-18-10_ _ _ VKN-3
24
110 230
400
24D
110D
7.5
10
10
32
0
1
J7KN-18-01_ _ _ VKN-3
24
110 230
400
24D
110D
11
10
10
32
1
0
J7KN-22-10_ _ _ VKN-3
24
110 230
400
24D
110D
11
10
10
32
0
1
J7KN-22-01_ _ _ VKN-3
24
110 230
400
24D
110D
14 A
18 A
22 A
Other coil voltages available on request
J7TKN-B
J7TKN-C
J7TKN-F
–
67x45x82.5
–
5.5
14 A
J7TKN-B
VDC
4
22 A
506
Coil voltage *1 ,
replace _ _ _ with:
NO
18 A
*1
Order code
AC1
690 V
A
110 A
AC for fuseless 3
load feeders
Size in mm
(HxWxD)
660 V
690 V
kW
22 A
AC/DC
Overload
relay
500 V
kW
18 A
3
Rated
Auxiliary
current contact
380 V
400 V
415 V
kW
14 A
DC
operated
solenoid
motor
contactor
Rating AC2, AC3
78x45x104.5
170x110x162
J7KN
Operation
AC
Motor contactors
Poles
4
DC
4
solenoid motor
contactor
AC/DC
*1
AC3
400 V
rated
motor
current
Rating AC2, AC3
Rated
current
Auxiliary
contact
Overload
relay
Size in mm
(HxWxD)
Coil voltage *1 , replace _ _ _ with:
Order code
380 V
400 V
415 V
kW
AC1
400 V
kW
AC1
690 V
A
NO
NC
10 A
4
17.5
25
0
0
J7KN-10-4_ _ _
24
110
230 400
14 A
5.5
17.5
25
0
0
J7KN-14-4_ _ _
24
110
230 400
18 A
7.5
22
32
0
0
J7KN-18-4_ _ _
24
110
230 400
22 A
11
22
32
0
0
J7KN-22-4_ _ _
24
110
230 400
10 A
4
17.5
25
0
0
J7KNG-10-4_ _ _
–
24D
110D
14 A
5.5
17.5
25
0
0
J7KNG-14-4_ _ _
24D
110D
18 A
7.5
22
32
0
0
J7KNG-18-4_ _ _
24D
110D
22 A
11
22
32
0
0
J7KNG-22-4_ _ _
24D
110D
150 A
75
159
230
0
0
175 A
90
173
250
0
0
VAC
–
67x45x82.5
–
67x45x82.5
170x110x162
VDC
–
J7KN-151-4_ _ _
24
110
230 400
24
110
J7KN-176-4_ _ _
24
110
230 400
24
110
Other coil voltages available on request
Accessories
Auxiliary contact
blocks
Rated operational current
Suitable for:
AC15
230 V
A
AC15
400 V
A
AC1
690 V
A
NO
3
2
10
1
–
J73KN-B-10
3
2
10
–
1
J73KN-B-01
3
2
10
–
–
J73KN-B-10U
3
2
10
–
–
J73KN-B-01U
6
4
25
1
–
J73KN-B-10A
6
4
25
–
1
J73KN-B-01A
3
2
10
1
1
J73KN-D-11F
3
2
10
2
2
J73KN-D-22F
J7KN-151…
to -176…
Order code
Suppressor units
NC
3
2
10
1
1
J73KN-D-11S
J7KN-24…
to KN-110 and
J7KN-200
3
2
10
1
1
J73KN-C-11S
3
2
10
2
2
J73KN-E-22
Pneumatic
timers
Function
Time
range
Contacts
NO
NC
ON-delay
0.1 to
40 s
1
ON-delay
10 to
180 s
1
0.1 to
40 s
–
10 to
180 s
–
Suitable for:
J7KN-10...
to -40…
OFF-delay
OFF-delay
Type
Applicable
coil
voltage
Suitable for
contactors
J7KNA
AC/DC
J7KN10-J7KN22
AC/DC
J7KN10-J7KN74
AC/DC
AC/DC
J7KNA
AC/DC
AC/DC
Varistor snap-on
coil terminals
110 to 230 V J74KN-A-VG230
Varistor snap-on
top of contactor
110 to 230 V J74KN-B-VG230
RC-unit snap-on
contactor
12 to 48 V
J74KN-D-RC24
48 to 127 V
J74KN-D-RC110
AC/DC
J7KN10-J7KN74
250 to 415 V J74KN-A-VG400
250 to 415 V J74KN-B-VG400
110 to 230 V J74KN-D-RC230
AC/DC
RC-unit snap-on
contactor
AC/DC
AC/DC
J7KN85-J7KN110
Order code
12 to 48 V
J74KN-C-RC24
48 to 127 V
J74KN-C-RC110
110 to 230 V J74KN-C-RC230
AC/DC
RC-unit to fix via
fixing band or
adhesive strip
with contactor
AC/DC
AC/DC
12 to 24 V
J74KN-B-RC48
110 to 250 V J74KN-B-RC230
250 to 415 V J74KN-B-RC400
Order code
Additional terminals
single pole
Cable cross-sections
to clamp (mm2)
J74KN-B-TP40DA
Suitable for contactors
Solid or
stranded
Flexible
–
Flexible with
multi-core
cable end
–
J74KN-B-TP180DA
J7KN50 - KN74
4 to 35
6 to 25
4 to 25
J74KN-LG-9030
J7KN151 - KN176
16 to 120
–
16 to 95
J74KN-LG-11224
Terminal covers
Specification
Order code
J7KN151 - KN176
One unit
J74KN-LG-10404
Marking systems
Specification
Order code
Marking plate
2-section without marking,
divisible
J74KN-P487-1
Marking plate
4-section without marking,
divisible
J74KN-P245-1
1
J74KN-B-TP40IA
1
J74KN-B-TP180IA
Mechanical
interlocks
Interlocks contactor with contactor
Order code
Mounting
Order code + Order code
Horizontal
J7KN-10 to -40 + J7KN-10 to -40
J74KN-B-ML
J7KN-24 to -74 + J7KN-24 to -74
J74KN-C-ML
J7KN-85 to -110 + J7KN-85 to -110
J74KN-D-ML
J7KN-151 to -176 + J7KN-151 to -176
J74KN-E-ML
Order code
Suitable for contactors
Low voltage switchgear
J7KN-10…
to -74…
Contacts
Description
Coil voltages
Suffix to contactor type:
Contactor type
20
24
48
90
110
180
230
400
500
J7KN-10 to J7KN-74
–
yes
yes
–
yes
yes
yes
yes
yes
J7KN-85 to J7KN-110
yes
yes
yes
yes
yes
yes
yes
yes
yes
J7KN-151 to J7KN-200
–
yes
yes
–
yes
–
yes
yes
–
27
Specifications
507
J7TKN
Thermal overload relays
Thermal overload relays for J7 contactors
J7TKN relays protect motors against thermal overload. They can be mounted on the
contactor or separately. The relays comply with IEC 947 (single-phase sensitivity).
• Series of overload relays covering a setting range from 0.24 A to 220 A
• All components are finger proof
Ordering information
Applicable contactors
Setting range
Size in mm (HxWxD)
Order code
38.8x48.5x77
J7TKN-A-E18
D.O.L. (A)
Star-delta (A)
0.12 to 0.18
–
0.18 to 0.27
–
J7TKN-A-E27
0.27 to 0.4
–
J7TKN-A-E4
0.4 to 0.6
–
J7TKN-A-E6
0.6 to 0.9
–
J7TKN-A-E9
0.8 to 1.2
–
J7TKN-A-1E2
1.2 to 1.8
–
J7TKN-A-1E8
1.8 to 2.7
–
J7TKN-A-2E7
2.7 to 4
–
J7TKN-A-4
4 to 6
7 to 10.5
J7TKN-A-6
6 to 9
10.5 to 15.5
J7TKN-A-9
8 to 11
14 to 19
J7TKN-A-11
10 to 14
18 to 24
0.12 to 0.18
–
0.18 to 0.27
–
J7TKN-B-E27
0.27 to 0.4
–
J7TKN-B-E4
0.4 to 0.6
–
J7TKN-B-E6
0.6 to 0.9
–
J7TKN-B-E9
0.8 to 1.2
–
J7TKN-B-1E2
1.2 to 1.8
–
J7TKN-B-1E8
1.8 to 2.7
–
J7TKN-B-2E7
2.7 to 4
–
J7TKN-B-4
4 to 6
7 to 10.5
J7TKN-B-6
6 to 9
10.5 to 15.5
J7TKN-B-9
8 to 11
14 to 19
J7TKN-B-11
10 to 14
18 to 24
J7TKN-B-14
13 to 18
23 to 31
J7TKN-B-18
17 to 24
30 to 41
J7TKN-B-24
23 to 32
40 to 55
J7KN-24… to J7KN-40…
28 to 42
48 to 73
47x67x90
J7TKN-C-42
J7KN-50… to J7KN-74…
40 to 52
70 to 90
57x69x93
J7TKN-D-52
52 to 65
90 to 112
60 to 74
104 to 128
60 to 90
104 to 156
80 to 120
140 to 207
100 to 150
175 to 260
140 to 220
240 to 380
J7KNA-09…, J7KNA-12…
J7KN-10… to J7KN-40…
J7KN-85… to J7KN-150…
J7KN-175… to J7KN-200…
J7TKN-A-14
63.5x45x70
J7TKN-B-E18
J7TKN-B-32
J7TKN-D-65
J7TKN-D-74
101x107x102
J7TKN-E-90
J7TKN-E-120
113x190x176
J7TKN-F-150
J7TKN-F-210
Accessories
Busbar sets
Sets for single mounting
For overload relays
For contactors
Order code
J7TKN-F-150
J7KN-151, J7KN-176
J74TK-SU-176
J7TKN-F-210
J7KN-200
J74TK-SU-200
508
For overload
relays
Cable cross-section to clamp (mm2)
Solid or
stranded
Flexible
Flexible with
multi-core cable
J7TKN-A
0.75 to 6
0.75 to 4
0.5 to 4
J74TK-M
J7TKN-B
0.75 to 6
0.75 to 4
0.5 to 4
J74TK-SM
Order code
J7TKN
Thermal overload relays
Specifications
Type
J7TKN-A
Rated insulation voltage Ui
690 VAC
Permissible ambient
temperature
Operation
-25 to 60°C
Storage
-50 to 70°C
Trip class according to IEC 947-4-1
J7TKN-B
J7TKN-C
J7TKN-D
10 A
J7TKN-E
J7TKN-F
20 A
Solid or stranded mm2
0.75 to 6
0.75 to 2.5
0.75 to 6
0.75 to 10
4 to 35
–
–
Flexible mm2
0.75 to 4
0.5 to 2.5
1 to 4
0.75 to 6
6 to 25
–
–
Flexible with multi-core
cable end mm2
0.5 to 2.5
0.5 to 1.5
0.75 to 4
0.75 to 6
4 to 25
–
–
Cables per clamp
Number
1+1
2
2
1
–
–
Auxiliary connector
Solid mm2
0.75 to 2.5
Flexible mm2
0.5 to 2.5
Flexible with multi-core
cable end mm2
0.5 to 1.5
Number
2
same potential
690 VAC
different potential
440 VAC
24 V
5A
3A
4A
230 V
3A
2A
2.5 A
2.5 A
3A
3A
400 V
2A
1A
1.5 A
1.5 A
2A
2A
690 V
0.6 A
0.5 A
0.6 A
24 V
1.2 A
1A
1.2 A
110 V
0.15 A
220 V
0.1 A
Highest fuse rating gL (gG)
6A
4A
6A
Setting range
to 23 A
All
28 to 42 A
52 to 65 A
All
–
Power loss per current path (max.) Minimum setting value
1.1 W
1.1 W
1.3 W
2.9 W
1.1 W
–
Maximum setting value
2.3 W
2.3 W
3.3 W
4.5 W
2.5 W
–
Cable cross-section
Main connector
Cables per clamp
Auxiliary contacts
Rated operational current Ie
Utilization category DC13
Short circuit protection (without
welding 1 kA)
250 VAC
440 VAC
5A
Low voltage switchgear
Rated operational current Ie
Utilization category AC15
27
Rated insulation voltage Ui
509
J7MN
Motor protection circuit breakers
J7MN motor protection circuit breakers
from 0.10 A to 100 A
J7MN starters protect motors against thermal overload and short circuit.
The J7MN can be equipped with additional auxiliary contacts, tripping indicator
(alarm), undervoltage release and/or shunt release. All models can be locked
for safe maintenance.
•
•
•
•
•
Rated operational currents of 32 A for the rocker type
Rated operational currents of 32 A, 63 A and 100 A for the rotary types
Switching capacity is 100 kA/415 V up-to 13 A and 50 kA/415 V up-to 100 A
Electrical/mechanical link modules available up-to 11 kW motor protection units
All components are finger proof
Ordering information
Rated
current
in A
Suitable for motors
3 ~ 400 V kW
Current setting range
Thermal
overload release A
Instantaneous
short-circuit release A
Short-circuit breaking
capacity at 3 ~ 400 V kA
Size in mm (HxWxD)
Order code
0,16
–
0.10 - 0.16
0,25
0,06
0.16 - 0.25
2,1
100
98x45x75
J7MN-3P-E16
3,3
100
0,4
0,09
J7MN-3P-E25
0.25 - 0.4
5,2
100
0,63
J7MN-3P-E4
0,18
0.4 - 0.63
8,2
100
J7MN-3P-E63
1
0,25
0.63 - 1
13
100
J7MN-3P-1
1,6
0,55
1 - 1.6
20,8
100
J7MN-3P-1E6
2,5
0,75
1.6 - 2.5
32,5
100
J7MN-3P-2E5
4
1,5
2.5 - 4
52
100
J7MN-3P-4
6
2,2
4-6
78
100
J7MN-3P-6
8
3
5-8
104
100
J7MN-3P-8
10
4
6 - 10
130
50
J7MN-3P-10
13
5,5
9 - 13
169
50
J7MN-3P-13
17
7,5
11 - 17
221
20
J7MN-3P-17
22
7,5
14 - 22
286
15
J7MN-3P-22
26
11
18 - 26
338
15
J7MN-3P-26
32
15
22 - 32
416
15
0,16
–
0.10 - 0.16
2,1
100
0,25
0,06
0.16 - 0.25
3,3
100
J7MN-3R-E25
0,4
0,09
0.25 - 0.4
5,2
100
J7MN-3R-E4
0,63
0,18
0.4 - 0.63
8,2
100
J7MN-3R-E63
1
0,25
0.63 - 1
13
100
J7MN-3R-1
1,6
0,55
1 - 1.6
20,8
100
J7MN-3R-1E6
2,5
0,75
1.6 - 2.5
32,5
100
J7MN-3R-2E5
4
1,5
2.5 - 4
52
100
J7MN-3R-4
6
2,2
4-6
78
100
J7MN-3R-6
8
3
5-8
104
100
J7MN-3R-8
10
4
6 - 10
130
100
J7MN-3R-10
13
5,5
9 - 13
169
100
J7MN-3R-13
17
7,5
11 - 17
221
50
J7MN-3R-17
22
7,5
14 - 22
286
50
J7MN-3R-22
26
11
18 - 26
338
50
J7MN-3R-26
32
15
22 - 32
416
50
26
12,5
18 - 26
338
50
32
15
22 - 32
416
50
J7MN-6R-32
40
18,5
28 - 40
520
50
J7MN-6R-40
50
22
34 - 50
650
50
J7MN-6R-50
63
30
45 - 63
819
50
63
30
45 - 63
819
50
75
37
55 - 75
975
50
J7MN-9R-75
90
45
70 - 90
1170
50
J7MN-9R-90
100
–
80 - 100
1300
50
J7MN-9R-100
510
J7MN-3P-32
98x45x100
J7MN-3R-E16
J7MN-3R-32
140x55x144
J7MN-6R-26
J7MN-6R-63
165x70x171
J7MN-9R-63
J7MN
Motor protection circuit breakers
Accessories
Description
Version
For circuit breaker
Order code
1 NO + 1 NC
All
J77MN-11F
Transverse auxiliary contact block
Contact block
2NO
J77MN-20F
2NC
J77MN-02F
Auxiliary contact block for left hand side mounting (max. 2 pc. per circuit breaker)
Contact block (9 mm)
1 NO + 1 NC
All
J77MN-11S
2NO
J77MN-20S
2NC
J77MN-02S
Signalling switch for left hand side mounting (max. 1 pc. per circuit breaker)
Signalling switch (18 mm)
1 NO + 1 NC any tripping condition
–
J77MN-TA-11S
1 NO + 1 NC short circuit tripping condition
–
J77MN-T-11S
All
–
Undervoltage releases for right hand side mounting (max 1 pc. per circuit breaker)
Trips the circuit breaker when the voltage is interrupted. Prevents AC 50 Hz
the motor from being restarted accidentally when the voltage is 24 V
restored, suitable for EMERGENCY STOP according to VDE 0113
110-127 V
AC 60 Hz
28 V
J77MN-U-24
120 V
J77MN-U-110
220-230 V
240-260 V
J77MN-U-230
240 V
277 V
J77MN-U-240
380-400 V
440-460 V
J77MN-U-400
415-440 V
460-480 V
J77MN-U-415
Shunt releases for right hand side mounting (max 1 pc. per circuit breaker)
Trips the circuit breaker when the
release coil is energized
AC 50 Hz
AC 60 Hz
24 V
28 V
All
–
J77MN-S-24
110-127 V
120 V
J77MN-S-110
220-230 V
240-260 V
J77MN-S-230
240 V
277 V
J77MN-S-240
380-400 V
440-460 V
J77MN-S-400
415-440 V
460-480 V
J77MN-S-415
Terminal block
Terminal block
Up to 600 V according to UL 489 not for transverse auxiliary
contact block
J7MN-3R
J77MN-TB32
J7MN-9R
J77MN-TB100
Type
J7MN-3P
J7MN-3R
J7MN-6R
J7MN-9R
Number of poles
3
3
3
3
32
63
100
IP20
IP20
IP20
Max. rated current Inmax
(= max. rated operational
current Ie)
A
32
Permissible ambient
temperature
Storage/transport
-50 to 80°C
Operation
-20 to 60°C
Rated operational voltage Ue V
690
Rated frequency
Hz
50/60
Rated insulation voltage Ui
V
690
Rated impulse withstand
voltage Uimp
kV
6
Utilization category
IEC 60 947-2 (circuit breaker) A
Low voltage switch gear
Specifications
According to IEC 60 947-4-1
10
Degree of protection
According to IEC 60 529
IP20
Phase failure sensitivity
According to IEC 60 947-4-1
Yes
Explosion protection
According to EC Directive
94191EC
Yes
Isolator characteristics
According to IEC 60 947-3
Yes
Main and EM. STOP switch
characteristics
According to IEC 60 204-1
(VDE113)
Yes
Safe isolation between main Up to 400 V + 10%
and auxiliary circuits
Up to 415 V + 5%
According to DIN VDE 0106
Part 101
Yes
Mechanical endurance
Operating cycles
27
IEC 60 947-4-1 (motor starter) AC-3
Class
Yes
100,000
100,000
50,000
50,000
Electrical endurance
100,000
100,000
25,000
25,000
Max. operating frequency per 1/h
hour (motor starts)
25
25
25
25
511
Monitoring products
THE COMPLETE MONITORING RANGE
K8 series – The smart way to protect your system
The K8 series offers you a flexible and complete one-stop shopping solution!
This monitoring range can be split into models for single-phase current and voltage control,
three-phase voltage control, conductive level control and a temperature alarm unit.
• 1-phase: full-span of range setting, all models with timer function
• 3-phase: wide range of global voltage settings
• Easy-to-set parameters
What type of monitoring is required?
Single-phase control
Current
Three-phase control
Voltage
Voltage
What type of control is required?
512
Window
Sequence/
phase loss
Multifunction
Sequence/phase
loss/asymmetry
Window
K8AB-VS
K8AB-VW
K8AB-PH
K8AB-PM
K8AB-PA
K8AB-PW
Page 517
Page 518
Page 519
Page 520
Page 521
Page 522
Over/under
Over/under
K8AB-AS
Page 516
Temperature
Level control
K8AB-TH
Single- or two-point
Leakage
Monitoring products
Which mounting method is required?
Which function is required?
Plug-in
DIN-rail
Page 402
Standard
Disconnection
detection
61F-D21T
K7L-AT50
K7L-AT50D
Page 526
Page 527
Page 527
DC power supply
DC power supply
61F-GP-N8
61F-GPN-BT/
-BC
Page 523
Page 525
28
AC power supply
513
Selection table
Selection criteria
Category
1-phase current
Model
K8AB-AS
Specialty Ideal for current
monitoring for
industrial heaters and
motors.
Sensing range 20 mA to 10 A, current
(configurable) transformer:
100/200 A
Features
Control
output
Supply
voltage DC
Supply voltage AC
24 VAC 
Phase-sequence
phase-loss
K8AB-VS
K8AB-VW
K8AB-PH
Ideal for voltage
monitoring for
industrial facilities and
equipment.
Ideal for voltage
monitoring for
industrial facilities and
equipment.
Ideal for phasesequence and phaseloss monitoring for
industrial facilities and
equipment.
60 mV to 600 V
60 mV to 600 V
Same as supply voltage
3-phase phasesequence phase-loss
3-phase asymmetry
and phase-sequence
phase-loss
K8AB-PM
K8AB-PA
Ideal for monitoring
3-phase power
supplies for industrial
facilities and
equipment.
Ideal for 3-phase
voltage asymmetry
monitoring for
industrial facilities and
equipment.


–
–
–
100 VAC –
–
–
–
–
–
110 VAC –
–
–
–
–
–
115 VAC 


–
–
–
120 VAC –
–
–
–
–
–
200 VAC –
–
–
–
–
–
220 VAC –
–
–
–
–
–
230 VAC 


–
–
–
240 VAC –
–
–
–
–
–
200 to 500 VAC –
–
–

–
–
200 to 240 VAC –
–
–
–
 (-PM1, 3-wire)
 (-PA1, 3-wire)
115 to 138 VAC –
–
–
–
 (-PM1, 4-wire)
 (-PA1, 4-wire)
380 to 480 VAC –
–
–
–
 (-PM2, 3-wire)
 (-PA2, 3-wire)
220 to 277 VAC –
–
–
–
 (-PM2, 4-wire)
 (-PA2, 4-wire)


–
–
–
12 to 24 VDC –
–
–
–
–
–
Transistor NPN –
–
–
–
–
–
Transistor PNP –
–
–
–
–
–
 (1 SPDT)
 (2 SPDT)
 (1 SPDT)
 (2 SPDT)
 (1 SPDT)
LED operation indicator 





Adjustable sensitivity –
–
–
–
–
–
Electrode types –
–
–
–
–
–
517
518
519
520
521
24 VDC 
Relay  (1 SPDT)
Page 516
514
1-phase voltage
Monitoring products
3-phase voltage
Conductive level controller
K8AB-PW
61F-GP-N8
61F-GPN-BT
Liquid leakage sensor amplifier
61F-GPN-BC
61F-D21T
K7L-AT50
K7L-AT50D
Ideal for monitoring
3-phase power supplies
for industrial facilities and
equipment.
Single or two-point
AC sine wave between
electrodes for stable
detection with no
electrolysis
AC sine wave between
electrodes for stable
detection with no
electrolysis
Ideal for level control for
industrial facilities and
equipment
Sensor amplifier, AC sine
wave between electrodes
for stable detection with
no electrolysis
Sensor amplifier with
disconnection detection
function
Same as supply voltage
4 to 50 k
0 to 100 k
1 to 100 k
10 to 100 k
0 to 50 M
1 to 50 M
–

–
–

–
–
–

–
–

–
–
–

–

–
–

–
–

–
–


–

–
–
–
–
 (-PW1, 3-wire)
–
–
 (-PW1, 4-wire)
–
–
 (-PW2, 3-wire)
–
–
 (-PW2, 4-wire)
–
–
–


–
–
–
–
–
–
–
–


–
–
–

–


–
–
–


–
–




–
–







–
–


–


–
Electrode holder: PS-_S, PS-31, BF-1 and BS-1
–
Liquid leakage sensor band F03-16PE
522
523
526
527
28
525
Monitoring products
 (2 SPDT)

Standard

Available
– No/not available
515
K8AB-AS
1-phase control
Single-phase current relay
These single-phase current relays monitor over- and undercurrents. Manual resetting
and automatic resetting are supported by one relay. The start-up lock and operating
time can be set separately. The relay warning status is easily monitored with the LED
indicator.
•
•
•
•
•
Single-phase current relay
In 22.5 mm wide industrial housing
Under or over control
Supply voltages: 24 VAC/24 VDC/115 VAC/230 VAC
Easy wiring with ferrules
Ordering information
Measuring current
Supply voltage
Order code
2 to 20 mA AC/DC, 10 to 100 mA AC/DC,
50 to 500 mA AC/DC
24VAC/DC
K8AB-AS1 24VAC/DC
100 to 115 VAC
K8AB-AS1 100-115 VAC
200 to 230 VAC
K8AB-AS1 200-230 VAC
24VAC/DC
K8AB-AS2 24VAC/DC
100 to 115 VAC
K8AB-AS2 100-115 VAC
200 to 230 VAC
K8AB-AS2 200-230 VAC
24VAC/DC
K8AB-AS3 24VAC/DC
100 to 115 VAC
K8AB-AS3 100-115 VAC
200 to 230 VAC
K8AB-AS3 200-230 VAC
0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC,
0.8 to 8 A AC/DC
10 to 100 A AC, 20 to 200 A AC
Accessories
Current transformer
Input range
Applicable relay
Order code
10 to 100 A AC, 20 to 200 A AC
K8AB-AS3
K8AC-CT200L
Note:The K8AB-AS3 is designed to be used in combination with the K8AC-CT200L (direct input not possible)
Specifications
Ambient temperature
Operating: -20 to 60°C (with no condensation or icing), storage: -40 to 70°C (with no condensation or icing)
Operating voltage range
85 to 110% of rated operating voltage
Rated power supply frequency
50/60 Hz ±5 Hz (AC power supply)
Output relays (SPDT) Resistive load
6 A at 250 VAC (cos = 1), 6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos = 0.4), 1 A at 30 VDC (L/R = 7 ms)
Minimum load
10 mA at 5 VDC
Maximum contact voltage
250 VAC
Maximum contact current
6 A AC
Maximum switching capacity
1,500 VA
Life expectancy
Mechanical: 10,000,000 operations, electrical: Make: 50,000 times, break: 30,000 times
Crimp terminals
Two solid wires of 2.5 mm2, two crimp terminals of 1.5 mm2 with insulation sleeves, can be tightened together
Degree of protection
Terminal section: IP20, rear case: IP40
Case material
ABS resin (self-extinguishing resin) UL94-V0
Weight
200 g
Operating power
Isolated power supply
24 VAC (3 VA)/24 VDC (1 W), 100 to 115 VAC (4 VA), 200 to 230 VAC (5 VA)
Operate (SV)
Operating value setting range
10 to 100% of maximum rated input value
Operating value
100% operation at set value
Hysteresis
5 to 50% of operating value
Resetting method
Manual reset/automatic reset (switchable)
Manual reset: Turn OFF operating power for 1 s or longer
Reset (HYS.)
Operating time (T)
0.1 to 30 s (value when input rapidly changes from 0 to 120%)
Operating power ON lock (LOCK)
0 to 30 s (value when input rapidly changes from 0 to 120%, lock timer starts upon input 30% of SV)
Setting accuracy
±10% of full scale
Time error
±10% of set value (minimum error: 50 ms)
Input frequency
Continuous input
K8AB-AS1/-AS2: DC input, 45 to 65 Hz; K8AB-AS3: 45 to 60 Hz
K8AB-AS1/-AS2
Continuous input: 115% of maximum input, 10 s max.: 125% of maximum input
K8AB-AS3
Continuous input: 240 A, 30 s max.: 400 A, 1 s max.: 1,200 A
Indicators
Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM): Red LED
Size in mm (HxWxD)
90x22.5x100
516
K8AB-VS
1-phase control
Single-phase voltage relay
These single-phase voltage relays are for monitoring over- and undervoltages.
Manual resetting and automatic resetting are supported by one relay. Relay warning
status can easily be monitored using the LED indicator.
•
•
•
•
•
Single-phase voltage relay
In 22.5 mm wide industrial housing
Under or over control
Supply voltages: 24 VAC/24 VDC/115 VAC/230 VAC
Easy wiring with ferrules
Ordering information
Measuring voltage
Supply voltage
Order code
6 to 60 mV AC/DC, 10 to 100 mV AC/DC,
30 to 300 mV AC/DC
24VAC/DC
K8AB-VS1 24VAC/DC
100 to 115 VAC
K8AB-VS1 100-115 VAC
200 to 230 VAC
K8AB-VS1 200-230 VAC
24VAC/DC
K8AB-VS2 24VAC/DC
100 to 115 VAC
K8AB-VS2 100-115 VAC
200 to 230 VAC
K8AB-VS2 200-230 VAC
24VAC/DC
K8AB-VS3 24VAC/DC
100 to 115 VAC
K8AB-VS3 100-115 VAC
200 to 230 VAC
K8AB-VS3 200-230 VAC
1 to 10 VAC/VDC, 3 to 30 VAC/VDC,
15 to 150 VAC/VDC
20 to 200 VAC/VDC, 30 to 300 VAC/VDC,
60 to 600 VAC/VDC
Ambient operating temperature
-20 to 60°C (with no condensation or icing)
Storage temperature
-40 to 70°C (with no condensation or icing)
Operating voltage range
85 to 110% of rated operating voltage
Rated power supply frequency
50/60 Hz ±5 Hz (AC power supply)
Output relays
Resistive load
6 A at 250 VAC (cos = 1), 6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos = 0.4), 1 A at 30 VDC (L/R = 7 ms)
Minimum load
10 mA at 5 VDC
Maximum contact voltage
250 VAC
Maximum contact current
6 A AC
Maximum switching capacity
1,500 VA
Mechanical life
10,000,000 operations
Electrical life
Make: 50,000 times, break: 30,000 times
Crimp terminals
Two solid wires of 2.5 mm2, two crimp terminals of 1.5 mm2 with insulation sleeves, can be tightened together
Degree of protection
Terminal section: IP20, rear case: IP40
Case colour
Munsell 5Y8/1 (ivory)
Case material
ABS resin (self-extinguishing resin) UL94-V0
Weight
200 g
Mounted to DIN-rail or via M4 screws
Operating power
Isolated power supply
24 VAC (4 VA)/24VDC (1 W, 100 to 115 VAC (4 VA), 200 to 230 VAC (5 VA)
Operate (SV)
Operating value setting range
10 to 100% of maximum rated input value
Operating value
100% operation at set value
Hysteresis
5 to 50% of operating value
Resetting method
Manual reset/automatic reset (switchable)
Manual reset: Turn OFF operating power for 1 s or longer
Reset (HYS.)
Operating time (T)
0.1 to 30 s (value when input rapidly changes from 0 to 120%)
Power ON lock (LOCK)
1 s or 5 s error ±0.5 s
(value when input rapidly changes from 0 to 100%. The operating time is the shortest at this point)
Setting accuracy
±10% of full scale
Time error
±10% of set value (minimum error: 50 ms)
Input frequency
40 to 500 Hz
Input impedance
K8AB-VS1: 9 k min., K8AB-VS2: 100 k min., K8AB-VS3: 1 M min.
Indicators
LED power (PWR): Green LED, relay output (RY): Yellow LED, alarm output (ALM): Red LED
Output relays
One SPDT relay (6 A at 250 VAC, resistive load)
Size in mm (HxWxD)
90x22.5x100
28
Mounting
Monitoring products
Specifications
517
K8AB-VW
1-phase control
Single-phase voltage relay, window type
For monitoring over- and undervoltages simultaneously. Manual resetting and
automatic resetting are supported by one relay. Separate settings and outputs
are supported for over- and undervoltages. Relay warning status can easily be
monitored with the LED indicator.
•
•
•
•
•
Single-phase voltage window relay
In 22.5 mm wide industrial housing
Under and over, low/low or high/high control
Supply voltages: 24 VAC/24 VDC/115 VAC/230 VAC
Easy wiring with ferrules
Ordering information
Measuring voltage
Supply voltage
Order code
6 to 60 mV AC/DC, 10 to 100 mV AC/DC,
30 to 300 mV AC/DC
24VAC/DC
K8AB-VW1 24VAC/DC
100 to 115 VAC
K8AB-VW1 100-115 VAC
200-230 VAC
K8AB-VW1 200-230 VAC
24VAC/DC
K8AB-VW2 24VAC/DC
100 to 115 VAC
K8AB-VW2 100-115 VAC
200 to 230 VAC
K8AB-VW2 200-230 VAC
24VAC/DC
K8AB-VW3 24VAC/DC
100 to 115 VAC
K8AB-VW3 100-115 VAC
200 to 230 VAC
K8AB-VW3 200-230 VAC
1 to 10 V AC/DC, 3 to 30 V AC/DC,
15 to 150 V AC/DC
20 to 200 V AC/DC, 30 to 300 V AC/DC,
60 to 600 V AC/DC
Specifications
Ambient operating temperature
-20 to 60°C (with no condensation or icing)
Storage temperature
-40 to 70°C (with no condensation or icing)
Operating voltage range
85 to 110% of rated operating voltage
Rated power supply frequency
50/60 Hz ±5 Hz (AC power supply)
Output relays (SPDT)
Resistive load
6 A at 250 VAC (cos = 1), 6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos = 0.4), 1 A at 30 VDC (L/R = 7 ms)
Minimum load
10 mA at 5 VDC
Maximum contact voltage
250 VAC
Maximum contact current
6 A AC
Maximum switching capacity
1,500 VA
Mechanical life
10,000,000 operations
Electrical life
Make: 50,000 times, break: 30,000 times
Crimp terminals
Two solid wires of 2.5 mm2, two crimp terminals of 1.5 mm2 with insulation sleeves, can be tightened together
Degree of protection
Terminal section: IP20, rear case: IP40
Case colour
Munsell 5Y8/1 (ivory)
Case material
ABS resin (self-extinguishing resin) UL94-V0
Weight
200 g
Mounting
Mounted to DIN-rail or via M4 screws
Operating power
Isolated power supply
24 VAC (4 VA)/24VDC (1 W), 100 to 115 VAC (4 VA), 200 to 230 VAC (5 VA)
Operation
(AL1 and AL2)
Operating value setting range
10 to 100% of maximum rated input value
Operating value
100% operation at set value
Reset (HYS.)
Hysteresis
5% of operating value (fixed)
Resetting method
Manual reset/automatic reset (switchable)
Manual reset: Turn OFF operating power for 1 s or longer
Operating time (T)
0.1 to 30 s (value when input rapidly changes from 0 to 120%)
Power ON lock (LOCK)
1 s or 5 s error ±0.5 s (value when input rapidly changes from 0 to 100%)
Setting accuracy
±10% of full scale
Time error
±10% of set value (minimum error: 50 ms)
Input frequency
40 to 500 Hz
Input impedance
K8AB-VW1: 9 k min., K8AB-VW2: 100 k min., K8AB-VW3: 1 M min.
Indicators
Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM 1/2): Red LED
Output relays
Two SPDT relays (6 A at 250 VAC, resistive load), normally closed operation (normally ON)
Size in mm (HxWxD)
90x22.5x100
518
K8AB-PH
3-phase control
3-phase sequence, phase loss relay
The K8AB-PH1 monitoring relay is designed to monitor 3-phase 3-wire supplies. It
simultaneously monitors phase sequence and phase loss during start up as well as
phase loss during operation. The output relay releases when alarm conditions are
detected, and the warning status can easily be monitored using the LED indicator.
Suitable for industrial facilities and equipment.
•
•
•
•
Monitors phase sequence and phase-loss simultaneously
Measuring range: 200 to 500 VAC
Power supply voltage is the same as measuring voltage
Operation reaction time: 0.1 s maximum
Ordering information
Rated input voltage
Order code
200 to 500 VAC
K8AB-PH1
Specifications
Ambient operating temperature
-20 to 60°C (with no condensation or icing)
Storage temperature
-40 to 70°C (with no condensation or icing)
Altitude
2,000 m max.
50/60 Hz ±5 Hz (AC power supply)
Resistive load
6 A at 250 VAC (cos = 1), 6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos = 0.4), 1 A at 30 VDC (L/R = 7 ms)
Minimum load
10 mA at 5 VDC
Maximum contact voltage
250 VAC
Maximum contact current
6 A AC
Maximum switching capacity
1,500 VA
Mechanical life
10,000,000 operations
Electrical life
Make: 50,000 times, break: 30,000 times
Terminal screw tightening torque
0.54 N·m
Degree of protection
Finger protection
Case colour
Munsell 5Y8/1 (ivory)
Case material
ABS resin (self-extinguishing resin) UL94-V0
Weight
110 g
Mounting
Mounted to DIN-rail or via M4 screws (tightening torque: 1.2 N·m)
Rated input voltage
Three-phase, three-wire mode, 200 to 500 VAC
Reversed phase and phase loss operating time
0.1 s max.
Resetting method
Automatic reset
Input frequency range
45 to 65 Hz
Overload capacity
Continuous input: 115% of maximum input, 10 s max.: 125% of maximum input
Fixed Phase Asymmetry Monitoring
Output relay releases when one phase-phase voltage drops below 80% of the other phase-phase voltage
Indicators
Power (PWR): Green LED, relay output (RY): Yellow LED
Output relays
One SPDT relay (6 A at 250 VAC, resistive load)
Size in mm (HxWxD)
90x22.5x100
Monitoring products
Output relays
28
Input frequency
519
K8AB-PM
3-phase control
3-phase voltage, phase sequence, phase loss
relay
K8AB-PM monitors overvoltages, undervoltages, phase sequence and phase loss
for 3-phase, 3-wire or 4-wire power supplies, in one unit. This relay features a switch
setting for 3-phase, 3-wire or 3-phase, 4-wire power supply.
•
•
•
•
•
Worldwide power specifications supported by one unit
Phase sequence, phase loss: Operation reaction time 0.1 s maximum
Overvoltages or undervoltages: Operation time setting from 0.1 to 30 s
Relay warning status can easily be monitored using the LED indicator
Easy wiring with ferrules
Ordering information
Rated input
Order code
3-phase 3-wire mode
200, 220, 230, 240 VAC
3-phase 4-wire mode
115, 127, 133, 138 VAC
3-phase 3-wire mode
380, 400, 415, 480 VAC
3-phase 4-wire mode
220, 230, 240, 277 VAC
K8AB-PM1
K8AB-PM2
Specifications
Ambient operating temperature
-20 to 60°C (with no condensation or icing)
Ambient operating humidity
25 to 85%
Voltage fluctuation range
85 to 110% of rated input voltage
Input frequency
Output relays
50/60 Hz ±5 Hz (AC power supply)
Resistive load
6 A at 250 VAC (cos = 1), 6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos = 0.4), 1 A at 30 VDC (L/R = 7 ms)
Minimum load
10 mA at 5 VDC
Maximum contact voltage
250 VAC
Maximum contact current
6 A AC
Maximum switching capacity
1,500 VA
Mechanical life
10,000,000 operations
Electrical life
Make: 50,000 times, break: 30,000 times
Crimp terminals
Two solid wires of 2.5 mm2, two crimp terminals of 1.5 mm2 with insulation sleeves, can be tightened together
Degree of protection
Terminal section: IP20, rear case: IP40
Case colour
Munsell 5Y8/1 (ivory)
Case material
ABS resin (self-extinguishing resin) UL94-V0
Weight
200 g
Mounting
Rated input voltage
Mounted to DIN-rail or via M4 screws
K8AB-PM1
3-phase, 3-wire mode: 200, 220, 230, 240 VAC, 3-phase, 4-wire mode: 115, 127, 133, 138 VAC
K8AB-PM2
3-phase, 3-wire mode: 380, 400, 415, 480 VAC, 3-phase, 4-wire mode: 220, 230, 240, 277 VAC
Operation (overvoltage or Operating value setting range
undervoltage)
Reset (HYS.)
Operating time (T)
Overvoltage = -30 to 25% of maximum rated input voltage *1
Undervoltage = -30 to 25% of maximum rated input voltage *1
Operating value
100% operation at set value
Hysteresis
5% of operating value (fixed)
Resetting method
Automatic reset
Overvoltage/undervoltage
0.1 to 30 s (value when input rapidly changes from 0 to 120%)
Phase-sequence, phase-loss
0.1 s max. (value when input rapidly changes from 0 to 100%)
Power ON lock (LOCK)
1 s or 5 s error ±0.5 s
(value when input rapidly changes from 0 to 100%. The operating time is the shortest at this point)
Setting accuracy
±10% of full scale
Time error
±10% of set value (minimum error: 50 ms)
Input frequency
45 to 65 Hz
Input impedance
100 k min.
Indicators
Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM 1/2): Red LED
Output relays
Two SPDT relays (6 A at 250 VAC, resistive load), normally closed operation (normally ON)
(separate outputs possible for overvoltages and undervoltages)
Size in mm (HxWxD)
90x22.5x100
*1
The rated input voltage is switched with a switch
520
K8AB-PA
3-phase control
3-phase asymmetry, phase sequence, phase
loss relay
Monitors voltage asymmetry, phase sequence and phase loss for
3-phase 3-wire or 4-wire power supplies, in one unit.
•
•
•
•
•
Worldwide power specifications supported by one unit
Phase sequence, phase loss: Operation reaction time 0.1 s maximum
Asymmetry: Operation time setting from 0.1 to 30 s
Reset method: Automatic
Power ON lock: 1 s or 5 s
Ordering information
Rated input
Order code
3-phase 3-wire mode
200, 220, 230, 240 VAC
3-phase 4-wire mode
115, 127, 133, 138 VAC
3-phase 3-wire mode
380, 400, 415, 480 VAC
3-phase 4-wire mode
220, 230, 240, 277 VAC
K8AB-PA1
K8AB-PA2
Specifications
Ambient operating temperature
-20 to 60°C (with no condensation or icing)
Storage temperature
-40 to 70°C (with no condensation or icing)
Altitude
2,000 m max.
Voltage fluctuation range
85 to 110% of rated input voltage
Input frequency
50/60 Hz ±5 Hz (AC power supply)
Resistive load
6 A at 250 VAC (cos = 1), 6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos = 0.4), 1 A at 30 VDC (L/R = 7 ms)
Minimum load
10 mA at 5 VDC
Maximum contact voltage
250 VAC
Maximum contact current
6 A AC
Maximum switching capacity
1,500 VA
Mechanical life
10,000,000 operations
Electrical life
Make: 50,000 times, break: 30,000 times
Crimp terminals
Two solid wires of 2.5 mm2, two crimp terminals of 1.5 mm2 with insulation sleeves, can be tightened together
Degree of protection
Terminal section: IP20, rear case: IP40
Case colour
Munsell 5Y8/1 (ivory)
Case material
ABS resin (self-extinguishing resin) UL94-V0
Weight
200 g
K8AB-PA1
3-phase, 3-wire mode: 200, 220, 230, 240 VAC, 3-phase, 4-wire mode: 115, 127, 133, 138 VAC
K8AB-PA2
3-phase, 3-wire mode: 380, 400, 415, 480 VAC, 3-phase, 4-wire mode: 220, 230, 240, 277 VAC
Asymmetry operation
(ASY.)
Operating value setting range
Asymmetry rate: 2 to 22%
Operating value
100% operation at set value
Asymmetry operating value = rated input voltage x asymmetry set value [%]
The asymmetry operation will function when the difference between the highest and lowest voltage phases equals or exceeds the
asymmetry operating value
Reset (HYS.)
Hysteresis
5% of operating value (fixed)
Resetting method
Automatic reset
Asymmetry
0.1 s to 30 s (value when input rapidly changes from 0 to 120%)
Phase-sequence, phase-loss
0.1 s max. (value when input rapidly changes from 0 to 100%)
Operating time (T)
Power ON lock (LOCK)
1 s or 5 s (value when input rapidly changes from 0 to 100%. The operating time is the shortest at this point)
Setting accuracy
±10% of full scale
Time error
±10% of set value (minimum error: 50 ms)
Input frequency
45 to 65 Hz
Input impedance
100 k min.
Indicators
Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM 1/2): Red LED
Output relays
One SPDT relay (6 A at 250 VAC, resistive load), normally closed operation (normally ON)
Size in mm (HxWxD)
90x22.5x100
28
Rated input voltage
Monitoring products
Output relays
521
K8AB-PW
3-phase control
3-phase voltage relay
Monitors overvoltages and undervoltages for 3-phase 3-wire or 4-wire power supplies, in one unit. Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
•
•
•
•
•
Overvoltages or undervoltages: Operation time setting from 0.1 to 30 s
Relay warning status can easily be monitored using the LED indicator
Separate outputs possible for overvoltages and undervoltages
Reset method: Automatic
Power ON lock: 1 s or 5 s
Ordering information
Rated input
Order code
3-phase 3-wire mode
200, 220, 230, 240 VAC
3-phase 4-wire mode
115, 127, 133, 138 VAC
3-phase 3-wire mode
380, 400, 415, 480 VAC
3-phase 4-wire mode
220, 230, 240, 277 VAC
K8AB-PW1
K8AB-PW2
Specifications
Ambient operating temperature
-20 to 60°C (with no condensation or icing)
Storage temperature
-40 to 70°C (with no condensation or icing)
Altitude
2,000 m max.
Voltage fluctuation rang
85 to 110% of rated input voltage
Input frequency
Output relays
50/60 Hz ±5 Hz (AC power supply)
Resistive load
6 A at 250 VAC (cos = 1), 6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos = 0.4), 1 A at 30 VDC (L/R = 7 ms)
Minimum load
10 mA at 5 VDC
Maximum contact voltage
250 VAC
Maximum contact current
6 A AC
Maximum switching capacity
1,500 VA
Mechanical life
10,000,000 operations
Electrical life
Make: 50,000 times, break: 30,000 times
Crimp terminals
Two solid wires of 2.5 mm2, two crimp terminals of 1.5 mm2 with insulation sleeves, can be tightened together
Degree of protection
Terminal section: IP20, rear case: IP40
Case colour
Munsell 5Y8/1 (ivory)
Case material
ABS resin (self-extinguishing resin) UL94-V0
Weight
Rated input voltage
Operation (overvoltage
and undervoltage)
Reset (HYS.)
Operating time (T)
200 g
K8AB-PW1
3-phase, 3-wire mode: 200, 220, 230, 240 VAC, 3-phase, 4-wire mode: 115, 127, 133, 138 VAC
K8AB-PW2
3-phase, 3-wire mode: 380, 400, 415, 480 VAC, 3-phase, 4-wire mode: 220, 230, 240, 277 VAC
Operating value setting range
Overvoltage = -30 to 25% of maximum rated input voltage *1
Undervoltage = -30 to 25% of maximum rated input voltage *1
Operating value
100% operation at set value
Hysteresis
5% of operating value (fixed)
Resetting method
Automatic reset
Overvoltage/undervoltage
0.1 to 30 s (value when input rapidly changes from 0 to 120%)
Power ON lock (LOCK)
1 s or 5 s (value when input rapidly changes from 0 to 100%. The operating time is the shortest at this point)
Setting accuracy
±10% of full scale
Time error
±10% of set value (minimum error: 50 ms)
Input frequency
45 to 65 Hz
Input impedance
100 k min.
Indicators
Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM 1/2): Red LED
Output relays
Two SPDT relays (6 A at 250 VAC, resistive load), normally closed operation (normally ON)
(separate outputs possible for overvoltages and undervoltages)
Size in mm (HxWxD)
90x22.5x100
*1
The rated input voltage is switched with a switch
522
61F-GP-N8
Conductive level controller
Compact plug-in (8-pin) level controller
The 61F-GP-N8 can be used for single- or two-point level control of conductive
materials, both liquids and solids. These products are equipped with a red LED
operation indicator.
•
•
•
•
•
Low-voltage (AC) electrodes (8 VAC or 24 VAC)
Operation range: 4 to 15 k, 70 to 300 k
Detection method: Conductive
Probes need to be ordered separately
Conforms to EMC and LVD directives, UL/CSA approved
Ordering information
Application
Type
Order code
Ordinary purified water or sewage water
General purpose type
61F-GP-N8 24AC
61F-GP-N8 110AC
61F-GP-N8 230AC
Ordinary purified water, where the distance between sewage pumps and water tanks or
between receiver tanks and supply tanks is long or where remote control is required
Long-distance type
2 km
61F-GP-N8L 24AC 2KM
61F-GP-N8L 110AC 2KM
61F-GP-N8L 230AC 2KM
4 km
61F-GP-N8L 24AC 4KM
61F-GP-N8L 110AC 4KM
61F-GP-N8L 230AC 4KM
Liquids with high specific resistance such as distilled water
High sensitivity type
61F-GP-N8H 24AC
61F-GP-N8H 110AC
61F-GP-N8H 230AC
Liquids with low specific resistance such as salt water, sewage water, acid chemicals,
alkali chemicals
Low sensitivity type
Ordinary purified or sewage water, with two-wired-type electrode holder
(incorporating a resistor of 6.8 k)
Two-wired type
61F-GP-N8D 24AC
61F-GP-N8D 110AC
61F-GP-N8D 230AC
61F-GP-N8R 24AC
61F-GP-N8R 110AC
61F-GP-N8R 230AC
DIN-rail mounting socket
PF083A-E
Back-connecting socket
PL08
Accessories
Applications
Mounting
style
Insulator
material
Max. temperature
Number of
electrodes
Order code
For city water and other general use.
Easy-to-replace separate versions for maintenance.
Flange
Phenol resin
70°C
3
PS-3S
When mounting space is limited.
Special 3­pole holder of small size and light weight.
Screw
Phenol resin
3, 300 mm
3, 1,000 mm
PS-31-300MM
PS-31-1000MM
Use for sewage, sea water, etc.,
having a low specific resistance.
Flange
Ceramics
150°C (without water drips or vapour on the 1
electrode holder surface)
BF-1
For resistance to high pressure.
Use in tanks with high temperature or pressure.
Screw
PTFE
250°C (without water drips or vapour on the 1
surface of the electrode holder)
BS-1
Electrode separators
Number of
electrodes
Order code
1
F03-14 1P
3
F03-14 3P
Monitoring products
Electrode holders
Applicable liquids
Material
Indication mark
Inscription
Order code
Purified city water, industrial water, sewage
Equivalent to Electrode (1 m long)
SUS 304
Connecting nut
(AISI-304)
Lock nut
1 line
–
F03-01 SUS201
–
–
F03-02 SUS201
–
–
F03-03 SUS201
SUS316
(AISI-316)
Electrode (1 m long)
2 lines
–
F03-01 SUS316
Connecting nut
–
6
F03-02 SUS316
Lock nut
–
316
F03-03 SUS316
Purified city water, industrial water, sewage,
dilute alkaline solution
Component
28
Electrodes, connecting, and lock nuts
523
61F-GP-N8
Conductive level controller
Specifications
Item
61F-GP-N8
Supply voltage
24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz
Operating voltage range
85 to 110% of rated voltage
Interelectrode voltage
Interelectrode current
Power consumption
Approx. 3.5 VA max.
Response time
Operate: 80 ms max., release: 160 ms max.
Cable length
1 km max.
Control output
1 A, 250 VAC (inductive load: Cos = 0.4), 3 A, 250 VAC (resistive load)
Ambient temperature
Operating: -10 to 55°C
Life expectancy
Electrical: 100,000 operations min., mechanical: 5,000,000 operations min
Size in mm (HxWxD)
49.9x38x70
524
61F-GP-N8L
61F-GP-N8H
61F-GP-N8D
8 VAC
24 VAC
8 VAC
Approx. 1 mA AC max.
Approx. 0.4 mA AC max.
Approx. 1 mA AC max.
50 m max.
1 km max.
2 km max. 4 km max.
61F-GP-N8R
800 m max.
61F-GPN-BT/-BC
Conductive level controller
Compact plug-in (11-pin) level controller
(DC supply)
This controller is for single- or two-point level control. 24 VDC supply allows for usage
in locations without AC power supply. Relay contact chattering usually caused by
waves has been eliminated by using open collector output, reducing contact wear.
•
•
•
•
•
Adjustable sensitivity: Operation range: 0 to 100 k
Red LED for operation indicator
Conforms to EMC and LVD directives
UL/CSA approved
Probes need to be ordered separately
Ordering information
Product name
Output
Order code
Conductive level controller
Open collector (NPN)
61F-GPN-BT 24VDC
Relay contact (SPST-NO)
61F-GPN-BC 24VDC
Front socket
PF113A-E
Accessories
Electrode holders
Applications
Mounting style
Insulator
material
Max. temperature
Number of
electrodes
Order code
For city water and other general use.
Easy-to-replace separate versions for maintenance.
Flange
Phenol resin
70°C
3
PS-3S
When mounting space is limited.
Special 3-pole holder of small size and light weight.
Screw
Phenol resin
3, 300 mm
3, 1000 mm
PS-31-300MM
PS-31-1000MM
Use for sewage, sea water, etc.,
having a low specific resistance.
Flange
Ceramics
150°C (without water drips or vapour on the 1
electrode holder surface)
BF-1
For resistance to high pressure.
Use in tanks with high temperature or pressure.
Screw
PTFE
250°C (without water drips or vapour on the 1
surface of the electrode holder)
BS-1
Electrode separators
Number of
electrodes
Order code
1
F03-14 1P
3
F03-14 3P
Electrodes, connecting, and lock nuts
Applicable liquids
Material
Indication mark
Inscription
Order code
Purified city water, industrial water, sewage
Equivalent to SUS Electrode (1 m long)
304
Connecting nut
(AISI-304)
Lock nut
1 line
–
F03-01 SUS201
–
–
F03-02 SUS201
–
–
F03-03 SUS201
SUS316
(AISI-316)
Electrode (1 m long)
2 lines
–
F03-01 SUS316
Connecting nut
–
6
F03-02 SUS316
Lock nut
–
316
F03-03 SUS316
Purified city water, industrial water, sewage,
dilute alkaline solution
Component
61F-GPN-BT
Rated voltage
24 VDC
61 F-GPN-BC
Allowable voltage range
85 to 110% of the rated voltage
Interelectrode voltage
5 VAC max.
Error
For scale of 0: +10 k, for scale of 100: ±10 k
Release resistance
200% max. of the operation resistance
Switching between supply and drainage
Terminals 7 and 8 open: Automatic drainage operation; terminals 7 and 8 shorted: Automatic supply operation
Output specifications
Open collector (NPN) 30 VDC, 100 mA max.
SPST-NO; 5 A, 240 VAC (resistive load)
2 A, 240 VAC (inductive load: cos = 0.4)
Life expectancy
–
Electrical: 100,000 operations min.
Mechanical: 20,000,000 operations min.
Wiring distance
100 m max.
Ambient operating temperature
-10 to 55°C
Response time
Operating: 1.5 s max., releasing: 3.0 s max.
Size in mm (HxWxD)
49.9x38x70
28
Item
Monitoring products
Specifications
525
61F-D21T
Conductive level controller
22.5 mm wide conductive level controller
The 61F-D21T is a conductive level controller in a 22.5 mm wide industrial housing.
Via DIP switches its function (supply or drainage) can be selected. This product is for
single- or two-point level control.
• Time delay function up to 10 s
• Supply voltages: 24 VAC/DC and 100-240 VAC
• Control output: Relay 6 A at 250 VAC resistive load
• Probes cable length: Max. 100 m from controller
• LED indicator: Green for power ON, yellow for output relay
Ordering information
Supply voltage
Order code
24 VAC/VDC
61F-D21T-V1 24 VAC/DC
100 to 240 VAC
61F-D21T-V1 100 to 240 VAC
Accessories
Electrode holders
Applications
Mounting style
Insulator material
Max. temperature
Number of
electrodes
Order code
For city water and other general use.
Easy-to-replace separate versions for maintenance.
Flange
Phenol resin
70°C
3
PS-3S
When mounting space is limited.
Special 3-pole holder of small size and light weight.
Screw
Phenol resin
3, 300 mm
3, 1000 mm
PS-31-300MM
PS-31-1000MM
Use for sewage, sea water, etc.,
having a low specific resistance.
Flange
Ceramics
150°C (without water drips or vapour on the 1
electrode holder surface)
BF-1
For resistance to high pressure.
Use in tanks with high temperature or pressure.
Screw
PTFE
250°C (without water drips or vapour on the 1
surface of the electrode holder)
BS-1
Electrode separators
Number of
electrodes
Order code
1
F03-14 1P
3
F03-14 3P
Electrodes, connecting, and lock nuts
Applicable liquids
Material
Component
Indication mark
Inscription
Order code
Purified city water, industrial water, sewage
Equivalent to SUS
304
(AISI-304)
Electrode (1 m long)
1 line
–
F03-01 SUS201
Connecting nut
–
–
F03-02 SUS201
Lock nut
–
–
F03-03 SUS201
SUS316
(AISI-316)
Electrode (1 m long)
2 lines
–
F03-01 SUS316
Connecting nut
–
6
F03-02 SUS316
Lock nut
–
316
F03-03 SUS316
Purified city water, industrial water, sewage,
dilute alkaline solution
Specifications
Rated voltage
24 VAC, 24 VDC, 100 to 240 VAC
Operating voltage range
85 to 110% of rated voltage
Voltage between electrodes
Power consumption
6 VAC p-p (approx. 20 Hz)
24 VDC
2 W max.
24 VAC
4 VA max.
100 to 240 VAC
5 VA max.
Operating resistance
10 k to 100 k (variable)
Reset resistance
250 k max.
Response time
Approx. 0.1 to 10 s (variable)
Cable length
100 m max. with completely insulated (600 V) cabtire cable with 3 conductors (0.75 mm2)
Control output
6 A at 250 VAC for resistive load at 20°C, 1 A at 250 VAC for inductive load cos = 0.4 at 20°C
Indicators
Green LED: Power, yellow LED: Control output
Ambient temperature
Operating: -20 to 60°C, storage: -30 to 70°C (with no condensation or icing)
Size in mm (HxWxD)
90x22.5x100
526
K7L
Leakage controller
Ultra-miniature liquid leakage sensor
amplifier
This very compact plug-in leakage controller fits into Omron's
G2R 8-pin sockets (P2RF-08-E). K7L detects a wide variety of liquids, ranging from
water to liquid chemicals with low conductivity.
•
•
•
•
•
Operation range: Up to 50 M
Four sensing ranges available
Detection method: Conductive
Two LEDs: Green for power supplied, red for output indication
Conforms to EMC and LVD Directives, UL/CSA approved
Ordering information
Product name
Characteristics
Order code
Product name
Characteristics
Order code
Liquid leakage sensor
amplifier
Standard
K7L-AT50
Sensors
Standard model (material: Polyethylene)
F03-16PE 5M
With disconnection function set
K7L-AT50D
For temperature and chemical resistance
(material: Polyethylene PTFE)
F03-16PT 5M
For flexibility and superior workability
(material: Plastic fiber braided cable)
F03-16SF 5M
For flexibility and visual confirmation
of leakage
(material: Plastic fiber braided cable)
F03-16SFC 5M
Easier to wipe off than the band type
F03-16PS
Sensing
band
With disconnection function sensor ampli- K7L-AT50D-S
fier only
Point
sensor
Electrodes have PTFE coating to resist chemicals F03-16PS-F
Accessories
Product name
Characteristics
Terminal blocks (10 pcs)
DIN-rail mounted
socket
Order code
Product name
Characteristics
Order code
F03-20
Mounting
brackets
and
stickers
Used for F03-16SF(C)
F03-25
Used for F03-16PE
(adhesive tape)
F03-26PES
Used for F03-16PE (screws)
(30 pcs)
F03-26PEN
Used for F03-16PT (screws)
F03-26PTN
With finger protection
P2RF-08-E
Without finger protection
P2RF-08
Sensing
band
stickers
Point sensor Used for F03-16PS
mounting
brackets
F03-26PS
12 to 24 VDC (allowable voltage fluctuation range: 10 to 30 VDC)
Operate resistance
0  to 50 M, variable
Range 0: 0 to 250 k
Range 1: 0 to 600 k
Range 2: 0 to 5 M
Range 3: 0 to 50 M
Release resistance
105% min. of operate resistance
Output configuration
NPN open-collector transistor output with 100 mA at 30 VDC max.
Wiring distance
Connecting cable: 50 m max.
Sensing band length: 10 m max.
Ambient temperature
Operating: -10 to 55°C
Power consumption
1 W max.
Response time
Operate: 800 ms max., release: 800 ms max.
Weight
Approx. 14 g
Disconnection detection function
(K7L-AT50D & K7L-AT50D-S only)
Detection signal: 10 VDC max., 200 ms, detection time: 10 s max.
Release: By resetting the power supply
Size in mm (HxWxD)
28.8x12.8x46
28
Rated power supply voltage
Monitoring products
Specifications
527
Limit switches
DOWNSIZE WITHOUT COMPROMISE
D4C – Compact, flat, high performing switches
With only a width of 16 mm these compact & flat switches will contribute to the demand to
down-sizing without compromising on specifications. The changeover contact inside can
switch up to 5 A/250 VA resistive load. A full range of actuators is available to meet all
your mechanical requirements.
• Slim, compact body sizes
• Wide range of actuators
• Strong metal housing with IP67 rating
General purpose
basic switch
What type is actuator?
Plunger, lever, spring
528
IP56
IP67
IP00/IP62
HL-5000
WL
Z
Page 533
Page 534
Page 539
Which type of switch is needed?
Enclosed
switch
What type is actuator?
What type is actuator?
Plunger, lever
Plunger, lever
IP67
IP67
29
Limit switches
Miniature
switch
D4C
Page 535
D4CC
D4E-_N
D4MC
Page 536
Page 537
Page 538
529
Selection table
General purpose basic
switch
Actuators
Features
Selection criteria
Type
530
Degree of protection
Rated current [A]
Model
Category
IEC
JIS
5 VDC
12 to 24 VDC
30 VDC
125/250 VDC
24 VAC
115 VAC
125 VAC
100 to 240 VAC
250 VAC
480 VAC
500 VAC
Microload type
Enclosed switch
Miniature limit switch
WL
D4C
D4CC
HL-5000
General purpose switches
IP65
Jet-proof
–
–
5
–
–
–
5
–
5
–
–
–
Operation indicator –
Adjustable rod lever
Adjustable roller lever
Bevel plunger
Center roller lever
Coil spring
Cross roller plunger
Fork lever lock
Hinge lever
Hinge roller lever
Hinge cross roller lever
Horizontal plunger
Horizontal roller plunger
Horizontal ball plunger
Leaf spring
Long hinge lever
Low force hinge lever
Low force wire hinge lever
One-way action hinge roller lever
One-way action short hinge roller lever
One-way action roller lever
Panel mount plunger
Panel mount pin plunger
Panel mount roller plunger
Panel mount cross roller plunger
Pin plunger
Plastic rod
Reverse hinge lever
Reverse hinge roller lever
Reverse short hinge roller lever
Roller leaf spring
Roller lever
Roller lever
Roller plunger
Sealed cross roller plunger
Sealed plunger
Sealed plunger roller
Short hinge cross roller lever
Short hinge lever
Short hinge roller lever
Short spring plunger
Side plunger
Side roller plunger horizontal
Side roller plunger vertical
Slim spring plunger
Spring plunger
Top ball plunger
Top plunger
Unidirectional short hinge roller lever
Variable rod lever
Variable roller lever
Two circuit limit switch


–
–

–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

–
–


–
–
–
–
–
–
–
–
–
–
–
–


Page 533
Special purpose switches
IP67
Immersion-proof
–
–
–
–
–
–
10
–
10
10
10
0.1 A
–
–
4
–
–
–
5
–
5
–
–
0.1 A
–
–
1
–
–
–
1
–
–
–
–
–



–
–
–
–
–
–

–
–
–



–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

–
–
–
–



–
–


–
–

534
–
–

–
–

–
–
–
–
–
–
–
–
–
–
–
–
–
–





–
–
–
–
–
–





–
–
–
–
–
–
–
–
–
–
–
–
–
–
535
–
–



–
–
–
–
–
–
–
–
–
–
–
–
–
–
–





–
–
–
–
–
–




–
–
–
–
–
–
–
–
–
–
–
–
–
–
536
Limit switches
Selection criteria
Degree of protection
Features
Rated current [A]
Standard
D4E-_N
D4MC
Special purpose switches
IP67
–
–
1
–
–
–
5
–
–
–
–
0.1 A
Operation indicator –
Adjustable rod lever
Adjustable roller lever
Bevel plunger
Center roller lever
Coil spring
Cross roller plunger
Fork lever lock
Hinge lever
Hinge roller lever
Hinge cross roller lever
Horizontal plunger
Horizontal roller plunger
Horizontal ball plunger
Leaf spring
Long hinge lever
Low force hinge lever
Low force wire hinge lever
One-way action hinge roller lever
One-way action short hinge roller lever
One-way action roller lever
Panel mount plunger
Panel mount pin plunger
Panel mount roller plunger
Panel mount cross roller plunger
Pin plunger
Plastic rod
Reverse hinge lever
Reverse hinge roller lever
Reverse short hinge roller lever
Roller leaf spring
Roller lever
Roller lever
Roller plunger
Sealed cross roller plunger
Sealed plunger
Sealed plunger roller
Short hinge cross roller lever
Short hinge lever
Short hinge roller lever
Short spring plunger
Side plunger
Side roller plunger horizontal
Side roller plunger vertical
Slim spring plunger
Spring plunger
Top ball plunger
Top plunger
Unidirectional short hinge roller lever
Variable rod lever
Variable roller lever
Actuators

Enclosed switch

Available
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

–
–
–
–

–
–
–
–
–






–
–
–
–
–
–
–
–
–
–
–
–
–
–
Page 537
– No/not available
–
–
6
–
–
0.5
10
–
10
3
–
0.1 A
General purpose basic
switch
Z
General purpose switches
IP00/IP62
(drip-proof)
–
–
–
–
–
–
15
–
15
0.1
–
0.1 A
–
–
–
–
–
–
–
–
–


–
–
–
–
–
–
–
–
–

–

–
–
–
–
–
–
–



–
–
–




–
–
–



–
–
–
–
–
–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–
–
–
–
–
538



–




–
–
–
–
–
–




–
–
–


–
–

–
–
539
Limit switches
Model
Category
IEC
JIS
5 VDC
12 to 24 VDC
30 VDC
125/250 VDC
24 VAC
115 VAC
125 VAC
100 to 240 VAC
250 VAC
480 VAC
500 VAC
Microload type
Small sealed switch
29
Type
531
532
HL-5000
Standard switches
Economical, miniature limit switch
With a highly rigid, dust- and drip-proof construction, HL-5000 can be used
in a variety of heavy industrial applications.
•
•
•
•
•
Highly rigid construction (head and cover snugly fit in box)
Smooth operation with greater overtravel
Easy-to-wire conduit opening design
Models with grounding terminals conform to the CE marking
Jet-proof IP65
Ordering information
Application
Operating force
max. (OF)
Release force
max. (RF)
Pre travel (PT)
Over travel (OT)
Movement
Operating
differential (MD) position (OP)
Size in mm
(HxWxD)
excl. actuator
Order code
Roller lever
7.35 N
0.98 N
20°
50°
12°
–
82.4x33x34
HL-5000G
Adjustable roller lever
7.35 N
0.98 N
20°
50°
12°
–
–
HL-5030G
Adjustable rod lever
7.35 N
0.98 N
20°
50°
12°
–
–
HL-5050G
Sealed plunger
8.83 N
1.47 N
1.5 mm
4 mm
1 mm
30 ±0.8 mm
60.6x33x34
HL-5100G
Sealed roller plunger
8.83 N
1.47 N
1.5 mm
4 mm
1 mm
40 ±0.8 mm
–
HL-5200G
Coil spring
1.47 N
–
30 mm
–
–
–
–
HL-5300G
Specifications
Resistive load
NC
Inductive load
Lamp load
NO
Inductive load
NC
NO
NC
Motor load
NC
NO
125 VAC
5A
1.5 A
0.7 A
3A
2A
1A
250 VAC
5A
1A
0.5 A
3A
1.5 A
0.8 A
12 VDC
5A
3A
4A
3A
24 VDC
5A
3A
4A
3A
Inrush current
NC
24 A max.
NO
12 A max.
Degree of protection
IP65
Life expectancy
Mechanical: 10,000,000 operations min. (under rated conditions)
Operating speed
5 mm/s to 0.5 m/s (HL-5000)
Operating frequency
Mechanical: 120 operations/min, electrical: 30 operations/min
Rated frequency
50/60 Hz
Ambient temperature
Operating: -5 to 65°C (with no icing)
Ambient humidity
Operating: 95% max.
Weight
Approx. 130 to 190 g
NO
Limit switches
Non-inductive load
Rated voltage
29
Ratings
533
WL
Standard switches
Wide selection of two circuit limit switches
A wide selection of models is available, including overtravel models with greater OT,
lamp equipped models for checking operation, low temperature and heat resistant
models and micro-load models. Various plungers and levers are also available.
•
•
•
•
•
Two circuit limit switch
Direct and pre-wiring
Metal housing, immersion-proof IP67
Ground terminal models are approved by EN and IEC and bear the CE marking
UL, CSA
Ordering information
Actuator
Order code
Ground terminal
No
Yes
Adjustable roller lever: Standard
WLCA12
WLCA12-G
Adjustable roller lever: Overtravel 90°
WLCA12-2N
WLCA12-2NG
Roller lever: Standard model (R38)
WLCA2
WLCA2-G
Roller lever: Overtravel 90°
WLCA2-2N
WLCA2-2NG
Roller lever: Standard, standard model (R50)
WLCA2-7
WLCA2-7G
Fork lever lock: Protective, WL-5A100
WLCA32-41
WLCA32-41G
Fork lever lock: Protective, WL-5A104
WLCA32-43
WLCA32-43G
Adjustable rod lever: Standard
WLCL
WLCL-G
Adjustable rod lever: Overtravel 90°, 25 to 140 mm
WLCL-2N
WLCL-2NG
Plunger: Top plunger
WLD
WLDG
Plunger: Top roller plunger
WLD2
WLD2-G
Plunger: Top ball plunger
WLD3
WLD3-G
Adjustable rod lever: Overtravel, high sensitivity, 80°, 350 to 380 mm
WLGL
WLGL-G
Flexible rod: Coil spring
WLNJ
WLNJ-G
Flexible rod: Coil spring, resin rod
WLNJ-2
WLNJ-2G
Flexible rod: Coil spring, multi-wire
WLNJ-30
WLNJ-30G
Flexible rod: Steel wire
WLNJ-S2
WLNJ-S2-G
Plunger: Horizontal roller plunger
WLSD2
WLSD2-G
Plunger: Horizontal ball plunger
WLSD3
WLSD3-G
Plunger: Horizontal plunger
WLSD
WLSD-G
Note:For other model please refer to the datasheet
Specifications
Rated voltage
Carry
current
Current
Make
Break
Make
Break
10 A
60 A
6A
7,200 VA
720 VA
240 VAC
30 A
3A
480 VAC
15 A
1.5 A
600 VAC
12 A
1.2 A
120 VAC
Volt-amperes
Agency
Standard
File No.
UL
UL508
E76675
CSA
CSA C22.2 No. 14
LR45746
TÜV Rheinland
EN60947-5-1
R9551016
Size in mm
(HxWxD)
68.7x40x42 (excluding the actuator)
534
Type
Standard,
overtravel
(except
highsensitivity
models),
and highprecision
models.
Overtravel
(highsensitivity
models)
Rated
voltage
Non-inductive load
Inductive load
Resistive load
Lamp load
Inductive load
Motor load
NC
NC
NO
NC
NO
NC
NO
125 VAC
10 A
3A
1.5 A 10 A
5A
2.5 A
250 VAC
10 A
2A
1A
3A
1.5 A
500 VAC
10 A
1.5 A 0.8 A 3 A
1.5 A 0.8 A
8 VDC
10 A
6A
3A
10 A
6A
14 VDC
10 A
6A
3A
10 A
6A
30 VDC
6A
4A
3A
6A
4A
125 VDC
0.8 A
0.2 A 0.2 A 0.8 A
0.2 A
250 VDC
0.4 A
0.1 A 0.1 A 0.4 A
0.1 A
125 VAC
5A
–
–
–
–
250 VAC
5A
–
–
–
–
125 VDC
0.4 A
–
–
–
–
250 VDC
0.2 A
–
–
–
–
10 A
NO
D4C
Miniature switches
Compact, 16 mm thick cable type switch
The D4C range of switches offers a wide choice of actuators. All switches are liquid
and dust resistant, conforming to IEC IP67. Various types are available: pre-wired,
low temperature, viscosity resistant, etc.
•
•
•
•
•
Enclosed miniature limit switch, only 16 mm thick
Metal housing with triple-sealed construction
LED indicator for easy monitoring
Ganged mounting for multiple switching
Mechanical life expectancy = 10 million, switching/min = 30
Ordering information
Actuator
Operating force Release force
max. (OF)
max. (RF)
Pre travel (PT)
Over travel (OT) Movement
differential
(MD)
Operating position Order code
(OP)
S-FLEX VCTF Cable
Pin plunger
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
15.7±1 mm
D4C-1201
Sealed plunger
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
24.9±1 mm
D4C-1231
Roller plunger
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
28.5±1 mm
D4C-1202
Sealed roller plunger
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
34.3±1 mm
D4C-1232
Crossroller plunger
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
28.5±1 mm
D4C-1203
Sealed crossroller plunger
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
34.3±1 mm
D4C-1233
Coil spring
1.47 N
–
15°
–
–
–
D4C-1250
Roller lever
5.69 N
1.47 N
25°
40°
3°
–
D4C-1220
Center roller lever plunger
6.67 N
1.47 N
10±3°
50°
3°
–
D4C-1260
3m
Note:For other product specifications please refer to the datasheet
Specifications
Standard
File number
TÜV Rheinland
EN60947-5-1
R9451333/J9950970
UL
UL508
E76675
CSA
CSA C22.2 No. 14
LR45746
Order code
Rated voltage
Non-inductive load
D4C-1_ _ _
Inductive load
Resistive load
Lamp load
Inrush current
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
125 VAC
5A
5A
1.5 A
0.7 A
3A
3A
1.3 A
1.3 A
250 VAC
5A
5A
1A
0.5 A
2A
2A
1.5 A
0.8 A
20 A
max.
10 A
max.
8 VDC
5A
5A
2A
2A
5A
4A
3A
3A
14 VDC
5A
5A
2A
2A
4A
4A
3A
3A
30 VDC
4A
4A
2A
2A
3A
3A
3A
3A
125 VD
0.4 A
0.4 A
0.05 A
0.4 A
0.4 A
0.4 A
0.05 A
0.05 A
250 VDC
0.2 A
0.2 A
0.03 A
0.2 A
0.2 A
0.2 A
0.03 A
0.03 A
Limit switches
Agency
Degree of protection
IP67
Durability
Mechanical: 10,000,000 operations min.
Electrical: 200,000 operations min. (5A at 250 VAC, resistive load)
Operating speed
0.1 mm to 0.5 m/s (in case of plunger)
29
Note:For other loads, please refer to the datasheet
1 mm to 1 m/s (in case of roller lever)
Operating frequency
Mechanical: 120 operations/min
Electrical: 30 operations/min
Short-circuit protective device (SCPD)
10 A fuse type gG (IEC269)
Ambient temperature
Operating: -10 to 70°C (with no icing)
Weight
With 3 m VCTF cable: 360 g; with 5 m VCTF cable: 540 g
Size in mm (HxWxD)
49 or 51.5x34x16 (excluding the actuator)
535
D4CC
Miniature switches
Compact, 16 mm thick connector type switch
The D4CC family of limit switches comes as standard with a triple-seal construction
(IP67), cable connectors for easy switch replacement and an operation indicator for
easy monitoring.
•
•
•
•
•
Miniature limit switch
Various models including roller lever
Switches are only 16 mm thick with connector
Cable connectors for easy switch replacement
Immersion proof; IEC IP67, UL and CSA (type 3, 4 and 13)
Ordering information
Actuator
Operating
force max.
(OF)
Release force Pre travel (PT) Over travel
max. (RF)
(OT)
Movement
differential
(MD)
Operating
Order code
position (OP) 1 A at 125 VAC
Pin plunger
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
15.7 ±1 mm D4CC-1001
D4CC-3001
Roller plunger
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
28.5 ±1 mm D4CC-1002
D4CC-3002
Crossroller plunger
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
28.5 ±1 mm D4CC-1003
D4CC-3003
High-sensitivity roller lever
5.69 N
1.47 N
10 ±3°
50°
3°
D4CC-1024
D4CC-3024
Sealed pin plunger
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
24.9 ±1 mm D4CC-1031
D4CC-3031
Sealed roller plunger
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
34.3 ±1 mm D4CC-1032
D4CC-3032
Sealed crossroller plunger
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
34.3 ±1 mm D4CC-1033
D4CC-3033
Plastic rod
1.47 N
–
15°
–
–
–
D4CC-1050
D4CC-3050
Center roller lever
6.67 N
1.47 N
10 ±3°
50°
3°
–
D4CC-1060
D4CC-3060
Without indicator
1 A at 30 VDC
Without indicator
Accessories
Type
Appearance
Number of conductors
Cable length
Order code
VAC
Straight
4
2m
XS2F-A421-D90-A
5m
XS2F-A421-G90-A
10 m
XS2F-A421-J90-A
2m
XS2F-D421-D80-A
5m
XS2F-D421-G80-A
10 m
XS2F-D421-J80-A
VDC
Specifications
Rated
voltage
Carry current
120 VAC
1.0 A
Current
Volt-amperes
Rated voltage
Non-inductive load
Break
Make
Break
Resistive load
Lamp load
Inductive load
Motor load
3.6 A
3.6 A
432 VA
72 VA
NC
NO
NC
NO
NC
NO
NC
NO
125 VAC
1A
1A
1A
0.7 A
1A
1A
1A
1A
30 VDC
1A
1A
1A
1A
1A
1A
1A
1A
Agency
Standard
File number
UL
UL508
E76675
CSA
CSA C22.2 No. 14 LR45746
Degree of protection
IP67
Durability
Mechanical: 10,000,000 operations min., electrical: 200,000 operations min. (1 A at 125 VAC, resistive load)
Operating speed
Plunger: 0.1 mm to 0.5 m/s, roller lever: 1 mm to 1 m/s
Operating frequency
Mechanical: 120 operations/min, electrical: 30 operations/min
Ambient temperature
Operating: -10 to 70°C (with no icing)
Weight
Approx. 120 g (in the case of D4CC-1002)
Size in mm (HxWxD)
57 or 59.5x34x16 (excluding the actuator)
536
Inductive load
Make
D4E-_N
Enclosed switches
Slim, compact sealed switch
D4E-_N comes with flat springs that improve the lever ratio of the built-in switch,
ensuring smooth snap action and long life expectancy. Its one-touch connector
eliminates the need for tedious wiring operations and reduces downtime.
•
•
•
•
Protection cover protects the built-in switch from dust and oil
Plunger incorporates a tough, long-lasting seal cap
Minute load model with gold cladding is optimal for electronic control
IP67
Ordering information
Actuator
Operating
force max.
(OF)
Release force Pre travel (PT) Over travel
max. (RF)
(OT)
Movement
differential
(MD)
Operating
Order code
position (OP) One-touch connector type
General purpose
AC
Screw terminal type
General purpose
DC
Roller plunger
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
31.4 ±0.8 mm D4E-1A00N
D4E-1A10N
D4E-1A20N
Crossroller plunger
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
31.4 ±0.8 mm D4E-1B00N
D4E-1B10N
D4E-1B20N
Plunger
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
25.4 ±0.8 mm D4E-1C00N
D4E-1C10N
D4E-1C20N
Sealed roller plunger
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
41.3 ±0.8 mm D4E-1D00N
D4E-1D10N
D4E-1D20N
Sealed crossroller plunger
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
41.3 ±0.8 mm D4E-1E00N
D4E-1E10N
D4E-1E20N
Sealed plunger
11.77 N
4.90 N
1.5 mm
3 mm
(0.1 mm)
30 ±0.8 mm
D4E-1F00N
D4E-1F10N
D4E-1F20N
Roller lever
3.92 N
0.78 N
2 mm
4 mm
(0.3 mm)
23.1 ±0.8 mm D4E-1G00N
D4E-1G10N
D4E-1G20N
One-way action roller lever
3.92 N
0.78 N
2 mm
4 mm
(0.3 mm)
34.3 ±0.8 mm D4E-1H00N
D4E-1H10N
D4E-1H20N
Accessories
Type
Number of conductors
Current
Cable length
Applicable models
Order code
Straight
4
AC
2m
D4E-_ _ 00N
XS2F-A421-D90-A
5m
DC
XS2F-A421-G90-A
2m
D4E-_ _ 10N
XS2F-D421-D80-A
5m
XS2F-D421-G80-A
Specifications
Non-inductive load
Resistive load
NC
Inductive load
Lamp load
NO
NC
Microload
Inductive load
NO
NC
Motor load
NO
Resistive load
NC
NO
NC
125 VAC
5 (1) A
1.5 (1) A
3 (1) A
2 (1) A
1 (1) A
0.1 A
250 VAC
5 (1) A
1.5 (1) A
3 (1) A
1A
0.5 A
–
8 VDC
5 (1) A
–
1.5 (1) A
–
0.1 A
14 VDC
5 (1) A
–
1.5 (1) A
–
0.1 A
30 VDC
5 (1) A
–
1.5 (1) A
–
0.1 A
125 VDC
0.5 A
–
0.05 A
–
–
250 VDC
0.25 A
–
0.03 A
–
–
NO
Limit switches
Rated voltage
Agency
Standard
File number
UL
UL508
E76675
CSA
CSA C22.2 No. 14
LR45746
TÜV Rheinland
EN60947-5-1
R9551015
Degree of protection
IP67
Durability
Mechanical: 10,000,000 operations min., electrical: 500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed
0.1 mm to 0.5 m/sec
Operating frequency
Mechanical: 120 operations/min
Electrical: 30 operations/min
Ambient temperature
Operating: -10 to 80°C (with no icing)
Weight
Approx. 86 g (in case of roller plunger)
Size in mm (HxWxD)
32.9x18x57 (excluding the actuator)
29
Note:The above current ratings are for a standard current and the values in parentheses are for models with a connector
537
D4MC
Enclosed switches
Economical, high utility enclosed switch
D4MC provides users with high precision and a long life (10,000,000 mechanical
operations). It is sealed with a gasket diaphragm without use of any adhesive or pin,
making it suitable for applications demanding higher mechanical strength and for
dust-proof and drip-proof applications.
• Various models, plungers and levers available
• Panel-mount versions have the same operating position as the Z basic switch
• IP67, UL, CSA
Ordering information
Actuator
Operating force Release force
max. (OF)
max. (RF)
Pre travel
(PT)
Over travel Movement differential Operating position
(OT)
(MD)
(OP)
Order code
Panel mount plunger
5.88 N
0.98 N
1.6 mm
5 mm
0.2 mm
21.8 ±1.2 mm
D4MC-5000
Panel mount roller
5.88 N
0.98 N
1.6 mm
5 mm
0.2 mm
33.4 ±1.2 mm
D4MC-5020
Panel mount crossroller
5.88 N
0.98 N
1.6 mm
5 mm
0.2 mm
33.4 ±1.2 mm
D4MC-5040
Short hinge lever
2.55 N
0.34 N
–
2.5 mm
1.7 mm
25 ±1 mm
D4MC-1020
Hinge lever
1.67 N
0.25 N
–
4 mm
3 mm
25 ±1 mm
D4MC-1000
Hinge roller lever
1.96 N
0.39 N
–
5 mm
3 mm
40 ±1 mm
D4MC-2000
Short hinge roller
2.94 N
0.39 N
–
2 mm
1.5 mm
40 ±1 mm
D4MC-2020
One-way action short hinge roller
2.94 N
0.39 N
–
2 mm
1.5 mm
50 ±1 mm
D4MC-3030
Note:Use moulded terminal models when using the switch under one of the following conditions: dusty, high amount of dripping oil or high humidity
Specifications
Rated voltage
Non-inductive load
Inductive load
Resistive load
Lamp load
Inductive load
Motor load
NC
NC
NO
NC
NC
NO
NO
Rated voltage
Carry current
NO
120 VAC
10 A
240 VAC
125 VAC
10 A
3A
1.5 A
10 A
5A
2.5 A
250 VAC
10 A
2.5 A
1.25 A
10 A
3A
1.5 A
480 VAC
3A
1.5 A
0.75 A
2.5 A
1.5 A
0.75 A
8 VDC
10 A
3A
1.5 A
6A
5A
2.5 A
14VDC
10 A
3A
1.5 A
6 A0.75
5A
2.5 A
30 VDC
6A
3A
1.5 A
5A
5A
2.5 A
125VDC
0.5 A
0.4 A
0.05 A
0.05 A
250 VDC
0.25 A
0.2 A
0.03 A
0.03 A
Degree of protection
IP67 (NEMA250: 6.6P)
Life expectancy
Mechanical: 10,000,000 operations min., electrical: 500,000 operations min.
Operating speed
0.05 mm/s to 0.5 m/s (at panel mount plunger)
Operating frequency
Mechanical: 120 operations/min, electrical: 20 operations/min
Pollution degree (operating environment)
3 (IEC947-5-1)
Protection against electric shock
Class II
PTI (tracking characteristics)
175
Switch category
D (IEC335)
Rated operating current (Ie)
10 A
Rated operating voltage (Ue)
250 VAC
Ambient temperature
Operating: -10 to 80°C (with no icing)
Weight
Approx. 71 g (at panel mount plunger)
Size in mm (HxWxD)
45x21.7x55 (excluding the actuator)
538
Current
Make
Break
60 A
6A
30 A
3A
Z
General purpose Z-size
Standard high-precision switch
Z basic switches provide a large switching capacity of 15 A with very high repeat
accuracy. They come in a wide range of variations in contact form for your selection:
basic, split-contact, maintained-contact and adjustable-contact gap types.
•
•
•
•
•
General purpose basic switch
A series of standard models for micro loads is available
High-precision switching
A wide range of variations in contact
Drip-proof IP00/IP62
Ordering information
Contact
gap
Actuator
Order code
Solder terminal
Screw terminal
15 A
0.5 mm
Pin plunger
Z-15G
Z-15G-B
Short spring plunger
Z-15GD
Z-15GD-B
Leaf spring (high OF)
Z-15GL
Z-15GL-B
Roller leaf spring
Z-15GL2
Z-15GL2-B
Reverse hinge lever
Z-15GM
Z-15GM-B
Reverse hinge roller lever
Z-15GM2
Z-15GM2-B
Reverse hinge short roller lever
Z-15GM22
Z-15GM22-B
Panel mount plunger (medium OP)
Z-15GQ
Z-15GQ-B
Panel mount plunger (low OP)
Z-15GQ3
Z-15GQ3-B
Panel mount plunger (high OP)
Z-15GQ8
Z-15GQ8-B
Panel mount cross roller plunger
Z-15GQ21
Z-15GQ21-B
Panel mount roller plunger
Z-15GQ22
Z-15GQ22-B
Slim spring plunger
Z-15GS
Z-15GS-B
Hinge lever (low OF)
Z-15GW
Z-15GW-B
Hinge roller lever
Z-15GW2
Z-15GW2-B
Short hinge lever
Z-15GW21
Z-15GW21-B
Short hinge roller lever
Z-15GW22
Z-15GW22-B
Unidirectional short hinge roller lever
(low OF)
Hinge roller lever (large roller)
Z-15GW2277
Z-15GW2277-B
Z-15GW25
Z-15GW25-B
Hinge lever (medium OF)
Z-15GW3
Z-15GW3-B
Low-force hinge lever
Z-15GW4
Z-15GW4-B
Hinge lever (high OF)
Z-15GW32
Z-15GW32-B
Short hinge cross roller lever
Z-15GW49
Z-15GW49-B
Hinge cross roller lever
Z-15GW54
Z-15GW54-B
Limit switches
Ratings
29
Note:Many other types are also available, please refer to the full datasheet.
Specifications
Agency
Standard
File number
UL
UL508
E41515
CSA
CSA C22.2 No. 55
LR21642
TÜV Rheinland
EN61058-1
R9451585
Degree of protection
General purpose: IP00, drip-proof: IP62
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
175
Switch category
D (IEC335-1)
Ambient operating temperature
General purpose: -25 to 80°C (with no icing)
Drip-proof: -15 to 80°C (with no icing)
Size in mm (HxWxD)
24.2x49.2x17.5 (excluding the actuator)
539
Pushbutton switches
16 MM SUB-ASSEMBLED PUSHBUTTON SWITCHES
A165 – Full range with IP65 rating
All our 16 mm pushbuttons are upgraded to IP65 rating. This will increase the reliability
of your application. The pushbuttons are very easy to assemble due to their modular
construction: Pushbutton + case + lamp (if applicable) + switch.
• Wide range of models: rectangular, square & round
• With or without lamp
• Easy assembly and installation
Which application is required?
Pushbutton switches
Indicator
Panel cutout dimensions?
16 dia.
22 dia.
16 dia.
22 dia.
Illumination?
540
Yes
No
Yes
No
Yes
Yes
A16L
A16
A22L
A22
M16
M22
Page 544
Page 544
Page 546
Page 548
Page 549
Page 546
541
30
Pushbutton switches
Selection table
542
Pushbutton switches
Selection criteria
Category
Model
Pushbutton switch
A16
Indicator
A22
M16
M22
Mounting Nut-mounting
Size 16 mm
22 mm
16 mm
22 mm
Red 



Yellow 




–
Pure yellow 
Green 



White 



Blue 



Red 



Yellow 




–
Pure yellow 
Green 



White 



Blue 



Red 

–
–
Yellow 

–
–
Green 

–
–
White 

–
–
Blue 

–
–
Black 

–
–
Momentary operation 

–
–
Self-holding 

–
–
6
–
–
Number of contacts 2
Form
Operating
voltage
Terminals
Switch ratings [A]
Legend plate 



125 VAC 5
10
–
–
250 VAC 3
6
–
–
30 VDC 3
10
–
–
10 A at 110 VAC,
6 A at 220 VAC
–
–
Solder 
–

–
PCB –
–

–
Screw-less Clamp –
5 A at 125 VAC,
Rated load 3 A at 250 VAC,
3 A at 30 VDC
–

–
5 VDC 



12 VDC 



24 VDC 



SPDT 
–
–
–
DPDT 
–
–
–
SPST-NO –

–
–
SPST-NC –

–
–
SPST-NO + SPST-NC –

–
–
DPST-NO –

–
–
DPST-NC –

–
–
546
548
549
Page 544

Standard

Available
Pushbutton switches
IP rating IP65
30
Features
Non-lighted
LED-lighted
Pushbutton colour
Incandescent
lamp-lighted
Shape
– No/not available
543
A16
Pushbutton switches
16 mm pushbutton switch
These sub-assembled pushbutton switches have a modular construction:
pushbutton + case + lamp (if applicable) + switch. A16 is a nut-mounted pushbutton
switch with a short mounting depth of less than 28.5mm below panel.
•
•
•
•
•
Wide variety of control and signal devices: lighted, non-lighted and buzzer
Quick and easy assembly, snap-in switch
Wide range of switching capacity from standard load to micro load
High reliability, IP65
UL, cUL, CSA and VDE approved, conforms to EN60947-5-1 and IEC947-5-1
Ordering information
Type
Colour
Order code
Degree of protection: Oil-resistant IP65
Rectangular
Square
Round
Red
A165L-JR
A165L-AR
A165L-TR
Yellow
A165L-JY
A165L-AY
A165L-TY
Pure yellow
A165L-JPY
A165L-APY
A165L-TPY
White
A165L-JW
A165L-AW
A165L-TW
Blue
A165L-JA
A165L-AA
A165L-TA
Non-lighted
Black
A165L-JB
A165L-AB
A165L-TB
LED
Green
A165L-JGY
A165L-AGY
A165L-TGY
Non-lighted/incandescent lamp
Green
A165L-JG
A165L-AG
A165L-TG
Non-lighted
LED
Incandescent lamp
Cases
Appearance Classification
Order code
Oil-resistant IP65
Momentary operation
Alternate operation
Rectangular (2-way guard)
A165-CJM
Square
A165-CAM
Round
A165-CTM
Rectangular (2-way guard)
A165-CJA
Square
A165-CAA
Round
A165-CTA
Switches
Appearance
Switches with reduced voltage lighting
Classification
Order code
Lighted/
Standard load/
SPDT
non-lighted
microload (common
(common use) use)
DPDT
Solder
A16-1
terminal
A16-2
SPDT
DPDT
A16-T1-2
DPDT Screw-less
clamp
A16-T1-2S
100 V
DPDT
A16-2P
200 V
Screwless
clamp
A16-2S
Type
Colour
Order code
5 VDC
12 VDC
24 VDC
LED
Red
A16-5DSR
A16-12DSR
A16-24DSR
Yellow
A16-5DSY
A16-12DSY
A16-24DSY
Green
A16-5DSG
A16-12DSG
A16-24DSG
White *1
A16-5DSW
A16-12DSW
A16-24DSW
Blue
A16-5DA
A16-12DA
A16-24DA
Type
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
Incandescent lamp
A16-5
A16-12
A16-24
Use the white LED together with white or pure yellow pushbuttons.
Order code
100 V Standard load/
microload
(common use)
PCB
A16-1P
terminal
Lamps
544
Classification
SPDT
DPDT
*1
Appearance
Solder terminal
A16-T1-1
A16-T2-2S
A16
Pushbutton switches
Accessories
Name
Appearance
Switch guards
Classification
Remarks
Order code
For rectangular models
Cannot be used with the dust cover
A16ZJ-5050
For square and round models
Dust covers
For rectangular models
Panel plugs
A16ZA-5050
Cannot be used with the switch guard
A16ZJ-5060
For square models
A16ZA-5060
For round models
A16ZT-5060
For rectangular models
Used for covering the panel cutouts for future panel expansion
A16ZJ-3003
For square models
A16ZA-3003
For round models
A16ZT-3003
Specifications
Momentary operation: 120 operations/minute max.
Alternate operation: 60 operations/minute max.
Electrical
20 operations/minute max.
Mechanical
Momentary operation: 2,000,000 operations min.
Alternate operation: 200,000 operations min.
Electrical
100,000 operations min.
Ambient temperature
Operating: -10 to 55°C (with no icing or condensation)
Storage: -25 to 65°C (with no icing or condensation)
Weight
Approx. 10 g (in the case of a lighted DPDT switch with solder terminals)
Size in mm (HxWxD)
Round/square: 18x18x28.5
rectangular:
18x24x28.5
Operating
characteristics
Pushbutton switch
Item
Screw-less clamp
Oil-resistant IP65
Recommended wire size
0.5 mm2 twisted wire or 0.8 mm dia. solid wire
Usable wires and Twisted wire
tensile strength Solid wire
0.3 mm2
SPDT
Operating force (OF) max. 2.94 N
Releasing force (RF) min. 0.29 N
Total travel (TT)
Approx. 3 mm
Pretravel (PT) max.
2.5 mm
Lock stroke (LTA) min.
0.5 mm
DPDT
4.91 N
Tensile strength
Length of exposed wire
0.5 mm2
0.75 mm2
1.25 mm2
0.5 mm dia. 0.8 mm dia. 1.0 mm dia.
10 N
20 N
30 N
40 N
10 ±1 mm
Pushbutton switches
Durability
Mechanical
30
Allowable operating
frequency
545
A22
Pushbutton switches
22 mm pushbutton switch
A22 comes in a wide variety of shapes and colours and is installable in 22-dia. or
25-dia. panel cutouts. The switch unit can easily be mounted. A22 is mounted using
either open-type (fork-type) or closed-type (round-type) crimp terminals.
•
•
•
•
•
Finger-protection mechanism on switch unit provided as standard feature
Increased wiring efficiency with three-row mounting of switch blocks
IP65 oil-resistant (non-lighted models), IP65 (lighted models)
Lighted and non-lighted, flat, projection and half- and full-guard versions
EN60947-5-1, UL and cUL approved
Ordering information
Pushbutton
Illumination Colour
Non-lighted
Lighted
Order code
Flat type
Projection type
Full-guard type Half-guard type
Square/projection Square/
type
full-guard type
Round/mushroom Round/
type
mushroom type
(30-dia. head)
(40-dia. head)
Red
A22-FR
A22-TR
A22-GR
A22-HR
A22-CR
A22-DR
A22-SR
A22-MR
Green
A22-FG
A22-TG
A22-GG
A22-HG
A22-CG
A22-DG
A22-SG
A22-MG
Yellow
A22-FY
A22-TY
A22-GY
A22-HY
A22-CY
A22-DY
A22-SY
A22-MY
White
A22-FW
A22-TW
A22-GW
A22-HW
A22-CW
A22-DW
A22-SW
A22-MW
Blue
A22-FA
A22-TA
A22-GA
A22-HA
A22-CA
A22-DA
A22-SA
A22-MA
Black
A22-FB
A22-TB
A22-GB
A22-HB
A22-CB
A22-DB
A22-SB
A22-MB
Red
–
A22L-TR
A22L-GR
A22L-HR
A22L-CR
A22L-DR
–
–
Green
–
A22L-TG
A22L-GG
A22L-HG
A22L-CG
A22L-DG
–
–
Yellow
–
A22L-TY
A22L-GY
A22L-HY
A22L-CY
A22L-DY
–
–
White
–
A22L-TW
A22L-GW
A22L-HW
A22L-CW
A22L-DW
–
–
Blue
–
A22L-TA
A22L-GA
A22L-HA
A22L-CA
A22L-DA
–
–
29.7 dia. x 12D
29.7 dia. x 19D
29.7 dia. x 19D 29.7 dia. x 12/18.5D 29.8 mm2 x 18D
29.8 mm2 x 18D
30 dia. x 32D
40 dia. x 32D
Buttonsize in mm
Switches
Switch
operation
Lamp – LED
Contacts
Oder code
Nonlighted
models
AC/DC
Without voltage
reduction unit
Momentary
Alternate
110 VAC
546
Order code
Operating voltage
With voltage reduction unit
DC
220 VAC
AC
6V
12 V
24 V
24 V
superbright
Red
A22-6DR
–
–
–
Green
A22-6DG
–
–
–
Yellow *1
A22-6DY
–
–
–
Blue
A22-6DA
–
–
–
Red
A22-6AR
–
–
–
Green
A22-6AG
–
–
–
Yellow *1
A22-6AY
–
–
–
Blue
A22-6AA
–
–
–
Red
–
A22-12AR
A22-24AR
A22-24ASR
Green
–
A22-12AG
A22-24AG
A22-24ASG
SPST-NO
A22-10M
A22L-10M
A22L-10M-T1
A22L-10M-T2
SPST-NC
A22-01M
A22L-01M
A22L-01M-T1
A22L-01M-T2
SPST-NO +
SPST-NC
A22-11M
A22L-11M
A22L-11M-T1
A22L-11M-T2
DPST-NO
A22-20M
A22L-20M
A22L-20M-T1
A22L-20M-T2
DPST-NC
A22-02M
A22L-02M
A22L-02M-T1
A22L-02M-T2
SPST-NO
A22-10A
A22L-10A
A22L-10A-T1
A22L-10A-T2
Yellow *1
–
A22-12AY
A22-24AY
A22-24ASY
Blue
–
A22-12AA
A22-24AA
A22-24ASA
AC and DC
SPST-NC
A22-01A
A22L-01A
A22L-01A-T1
A22L-01A-T2
SPST-NO +
SPST-NC
A22-11A
A22L-11A
A22L-11A-T1
A22L-11A-T2
DPST-NO
A22-20A
A22L-20A
A22L-20A-T1
A22L-20A-T2
Lamp - incandescent lamp
DPST-NC
A22-02A
A22L-02A
A22L-02A-T1
A22L-02A-T2
Order code
*1
Used when the pushbutton colour is yellow or white
Operating voltage
Switch blocks
Switch blocks
LED light
Lighted models
Standard load
Order code
SPST-NO
A22-10
SPST-NC
A22-01
DPST-NO
A22-20
DPST-NC
A22-02
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
A22-5
A22-12
A22-24
A22
Pushbutton switches
Accessories
Item
Lamp sockets
Direct lighting
Voltage-reduction lighting
Remarks
Order code
Used when changing the lighting method (LED only)
A22-TN
220 VAC
A22-T2
Mounting
latches
For momentary models
Order mounting latches only when mounting switch blocks or A22-3200
lamp sockets are purchased individually
Legend plate
frames
Large size
Snap-in legend plate is acrylic
Sealing caps
For projection models
With snap-in legend plate, without text, black
A22Z-3330
Three-throw spacer
Control boxes
(enclosures)
A22Z-3333
Without snap-in legend plate
Exclusively for A22
One hole
Two holes
Used to prevent dust or water from entering the
operation unit (pushbutton, etc.), colour: Opaque,
material: Silicon
A22Z-3600T
Used when mounting three non-lighted switches
A22Z-3003
Do not use DPST-NO or DPST-NC switches,
material: Polycarbonate resin
A22Z-B101
Three holes
Snap-in legend Standard size
plates
Without text
White
Transparent
White text on black background
A22Z-B103
Attached to the standard-size legend plate frame,
material: Acrylic
Without text
A22Z-3443W
A22Z-3443C
ON
A22Z-3443B-5
OFF
A22Z-3443B-6
DOWN
A22Z-3443B-8
POWER ON
Large size
A22Z-B102
White
A22Z-3443B-9
Attached to the large-size legend plate frame,
material: Acrylic
A22Z-3453W
“EMERGENCY STOP” is engraved on the plate.
Used as an emergency stop switch legend plate
A22Z-3466-1
Lamp extractor
Rubber tool used to easily replace lamps
A22Z-3901
Tightening wrench
Tool used to tighten nuts from the back of the panel
A22Z-3905
Transparent
For emergency 60-dia. round plate with black letters on a yellow background
stop switch
90-dia. round plate with black letters on a yellow background
A22Z-3453C
A22Z-3476-1
Specifications
Recognized organization
Standards
File number
LED indicators without voltage reduction unit
UL, cUL
UL508
E41515
Rated voltage
Rated current
Operating voltage
–
EN60947-5-1
–
6 VDC
60 mA (20 mA)
6 VDC ±5%
6 VAC
60 mA (20 mA)
6 VAC/VDC ±5%
12 VAC/VDC
30 mA (10 mA)
12 VAC/VDC ±5%
24 VAC/VDC
15 mA (10 mA)
24 VAC/VDC ±5%
10
Rated voltage
Rated current (A)
AC15
(inductive
load)
AC12
(resistive
load)
DC13
(inductive
load)
DC12
(resistive
load)
24 VAC
10
10
–
–
110 VAC
5
10
–
–
220 VAC
3
6
–
–
Incandescent lamp
380 VAC
2
3
–
–
440 VAC
1
2
–
–
Super-bright LED indicator
Rated voltage
Rated current
Operating voltage
24 VAC/VDC
15 mA
24 VAC/VDC ±5%
Rated voltage
Rated current
Operating voltage
6 VAC/VDC
200 mA
5 VAC/VDC
80 mA
12 VAC/VDC
24 VDC
–
–
1,5
10
14 VAC/VDC
110 VDC
–
–
0,5
2
28 VAC/VDC
40 mA
24 VAC/VDC
220 VDC
–
–
0,2
0,6
130 VAC/VDC
20 mA
100 VAC/VDC
380 VDC
–
–
0,1
0,2
Voltage-reduction lighting
Contacts (microload)
Rated applicable load
Minimum applicable load
50 mA at 5 VDC (resistive load) 1 mA at 5 VDC
Item
Rated voltage
Operating voltage
Applicable lamp
(BA8S/13_ gold)
110 VAC
95 to 115 VAC
LED Lamp (A22-24A_)
220 VAC
190 to 230 VAC
Pushbutton switches
Emergency stop switches
Knob-type selector switches
Non-lighted Lighted
Non-lighted Lighted
Non-lighted
Key-type selector switch
30 operations/minute max.
Manual release: 30 operations/minute max.,
automatic release: 30 operations/minute max.
Lighted
Non-lighted
Allowable
operating
frequency
Mechanical
Momentary operation:
60 operations/minute max.
Electrical
30 operations/minute max.
Durability
(number of
operations
min.)
Mechanical
Momentary operation:
5,000,000
Momentary operation: 300,000
500,000
100,000
500,000
Electrical
500,000
300,000
500,000
100,000
500,000
Ambient
temperature
Operating
-20 to 70°C
-20 to 55°C
-20 to 70°C
-20 to 55°C
-20 to 70°C
-20 to 55°C
-20 to 70°C
Storage
-40 to 70°C
-40 to 70°C
-40 to 70°C
-40 to 70°C
-40 to 70°C
-40 to 70°C
-40 to 70°C
IP65 (oil-resistant)
IP65
IP65 (oil-resistant)
30 operations/minute max.
Degree of protection
IP65
IP65
(oil-resistant)
IP65
IP65
(oil-resistant)
Size in mm (in-panel only)
34Hx34Wx54.7D, 34Hx34Wx72.7D for DPST switches
30
Rated carry
current (A)
Pushbutton switches
Contact ratings (standard load)
547
M16
Indicators
Indicators with a mounting aperture
of 16 mm
The M16 series of nut-mounted indicators comes in rectangular, square and
round versions. Due to its modular construction, assembly is quick and easy.
M16 comes in a wide variety of control and signal devices with a wide range of
switching capacities, from general load to micro load.
•
•
•
•
•
LED, incandescent and neon lamp
Snap-in switch unit
Short mounting depth, less than 28.5 mm below panel
High reliability, IP65
UL, CSA and VDE approved, conforms to EN60947-5-1
Ordering information
Pushbutton
Type
Display colour
Order code
IP65 oil-resistant
LED
Incandescent lamp
LED
Incandescent lamp
Rectangular
Square
Round
Red
A165L-JR
A165L-AR
A165L-TR
Yellow
A165L-JY
A165L-AY
A165L-TY
Pure yellow
A165L-JPY
A165L-APY
A165L-TPY
White
A165L-JW
A165L-AW
A165L-TW
Blue
A165L-JA
A165L-AA
A165L-TA
Green
A165L-JGY
A165L-AGY
A165L-TGY
Green
A165L-JG
A165L-AG
A165L-TG
Lamp
Type
Case
Colour
Order code
Classification
Operating voltage
IP65 oil-resistant
Order code
Rectangular
A165-CJM
5 VDC
12 VDC
24 VDC
Square
A165-CAM
Red
A16-5DSR
A16-12DSR
A16-24DSR
Round
A165-CTM
Yellow
A16-5DSY
A16-12DSY
A16-24DSY
Green
A16-5DSG
A16-12DSG
A16-24DSG
White
A16-5DSW
A16-12DSW
A16-24DSW
Blue
A16-5DA
A16-12DA
A16-24DA
Type
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
Incandescent lamp
A16-5
A16-12
A16-24
LED
Socket
Classification
Order code
Solder terminals
M16-0
PCB terminals
M16-0P
Screw-less clamp
Solder terminals
Screw-less clamp
M16-S
Voltage-reduction
lighting
100 V
M16-T1
100 V
M16-T1-S
200 V
M16-T2-S
Specifications
Allowable
operating
frequency
Mechanical
Momentary operation: 120 operations/minute max., alternate
operation: 60 operations/minute max.
Agency
Standards
File number
UL, cUL
UL508
E41515
Electrical
20 operations/minute max.
Ratings
Durability
Mechanical
Momentary operation: 2,000,000 operations min.,
alternate operation: 200,000 operations min.
Superbright LED
Electrical
100,000 operations min.
Degree of contamination
3 (IEC947-5-1)
Ambient temperature
Operating: -10 to 55°C
(with no icing or condensation)
Storage: -25 to 65°C
(with no icing or condensation)
Rated voltage
Rated current
Operating voltage
Built-in limiting
resistance
5 VDC
30 mA (15 mA)
5 VDC ±5%
33  (68 )
12 VDC
15 mA
12 VDC ±5%
270  (560 )
24 VDC
10 mA
24 VDC ±5%
1,600  (2,000 )
Weight
Approx. 10 g (in the case of a lighted DPDT switch with solder
terminals)
Incandescent lamp
Rated voltage
Rated current
Operating voltage
Size in mm
Round/square: 18Hx18Wx28.5D
rectangular:
18Hx24Wx28.5D
6 VAC/VDC
60 mA
5 VAC/VDC
14 VAC/VDC
40 mA
12 VAC/VDC
28 VAC/VDC
24 mA
24 VAC/VDC
548
M22
Indicators
Nut-mounted, 22 mm indicator,
with high visibility, illuminated buttons
The M22 series of indicators comes in 22 or 25 mm-diameter round versions.
They can easily be mounted and removal of the socket unit is also easy.
The finger protection mechanism on the lamp is provided as a standard feature.
M22 indicators can be equipped with an LED or incandescent lamp.
•
•
•
•
Available in 5 colours
Super-bright LEDs for all versions
Lamp sockets with or without transformers
UL and cUL approved
Ordering information
Lamp
Display
Appearance
Round/flat
Square/projection
IP65 oil-resistant
AC/DC
LED
light
Operating voltage
6V
12 V
24 V
24 V
superbright
Red
A22-6DR
–
–
–
Green
A22-6DG
–
–
–
M22-FW
Yellow
A22-6DY
–
–
–
Blue
M22-FA
Blue
A22-6DA
–
–
–
Red
M22-CR
Red
A22-6AR
–
–
–
A22-6AG
–
–
–
Colour of display
Order code
Red
M22-FR
Green
M22-FG
Yellow
M22-FY
White
AC
DC
Green
M22-CG
Green
Yellow
M22-CY
Yellow
A22-6AY
–
–
–
White
M22-CW
Blue
A22-6AA
–
–
–
Red
–
A22-12AR
A22-24AR
A22-24ASR
Green
–
A22-12AG
A22-24AG
A22-24ASG
Yellow
–
A22-12AY
A22-24AY
A22-24ASY
Blue
–
A22-12AA
A22-24AA
A22-24ASA
6 VAC/VDC
12 VAC/VDC
24 VAC/VDC
100 VAC/VDC
A22-5
A22-12
A22-24
A22-H1
Blue
M22-CA
AC and DC
Socket unit
Order code
Voltage-reduction circuits
Without voltage reduction unit
With voltage reduction unit (220 VAC)
M22-00
M22-00-T2
Incandescent lamp
Accessories
M22 uses the same accessories as A22. Please refer to the relevant information in the corresponding section for the A22.
Recognized organization
Standards
File number
Incandescent lamp
UL, cUL
UL508
E41515
Rated voltage
Rated current
Operating voltage
6 VAC/VDC
200 mA
5V
14 VAC/VDC
80 mA
12 V
LED lamp
Rated voltage
Rated current
Operating voltage
28 VAC/VDC
40 mA
24 V
6 VDC
60 mA (20 mA)
6 VDC ±5%
130 VAC/VDC
20 mA
100 V
6 VAC
60 mA (20 mA)
6 VAC ±5%
12 VAC/VDC
30 mA (10 mA)
12 VAC/VDC ±5%
24 VAC/VDC
15 mA (10 mA)
24 VAC/VDC ±5%
Pushbutton switches
Specifications
Superbright LED indicator
Rated voltage
Rated current
Operating voltage
24 VAC/VDC
15 mA
24 VAC/VDC ±5%
Rated voltage
Rated current
Operating voltage
110 VAC
95 to 115 VAC
LED lamp (A22-24_)
220 VAC
190 to 230 VAC
Ambient temperature
Operating: -20 to 55°C, storage: -40 to 70°C
Degree of protection
IP65
Electric shock protection class
Class II
PTI (tracking characteristic)
175
Degree of contamination
3 (IEC947-5-1)
Size in mm
Button: 29.7 dia.x16D, switch: 34Hx34Wx54.7D
30
Voltage-reduction lighting
549