ETA-SEQ6
Sequencer Controller
ETA-SEQ6
Sequencer Controller
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 1 –
Specifications are subject to change without notice.
ETAsys.com
ETA-SEQ6
Sequencer Controller
Description
The ETA Systems ETA-SEQ6 Sequencer Controller features 6 outputs that are configurable
individually to be either a 24VDC output or Hard Switch Contact Closure (CC). There are two separate
output sequence time delay trimmers ranging from 1 second to 6 minutes. Activation can be done
via the front panel or remotely via Hard Switch CC, Momentary Switch or DC Voltage. The ETA-SEQ6
also incorporates an Emergency Power Down (EPD) port for local fire codes. You can link two
ETA-SEQ6 units together giving you 12 sequenced outputs.
The ETA-SEQ6 is a compact (1.5" x 4" x 2.75") Time Saving Device that is designed to solve some
of the common audio system problems in the easiest, most efficient, and cost-effective way. It is
made from high quality components and includes removable individual I/O connectors for quick
and precise wiring, separate ground terminals for all I/Os assuring secured connections, and a
removable security cover for the system activation switch. The ETA-SEQ6 is highly efficient and
meets most energy standards as one 24V DC power supply (available separately) can power multiple
ETA Time Saving Devices.
Interfaceable ETA Products
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6 Sequenced Outputs
Assignable 24VDC or Hard Switch
Contact Closure (CC) per Output
Sequence 1 is Adjustable: Delay Time
1 Second to 6 Minutes
Sequences 2 - 6 are Adjustable: Delay Time
1 Second to 1 Minute
Remote Activation via 5-24VDC,
Momentary Contacts, Hard Switch Contacts
Status Indicator for Each Output
Emergency Power Down “EPD” Port
Link Out for Two ETA-SEQ6 Controllers
Voltage Output for Remote
LED Status Display
Separate Wiring Port for Each I/O
Cable Management System
Multiple Mounting Configurations
Removable Phoenix Style I/O Connectors
Meets Most Energy Standards
Compact Chassis Design
•
•
•
•
•
•
ETA-ECM20
ETA-ECM20M
ETA-ECM15SH
ETA-ECM20SH
ETA-ECM30
ETA-ECM2063
Installation
•
•
•
•
•
•
Churches
Restaurants
Sports Bars
Schools
Industrial Facilities
House of Worship
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 2 –
Specifications are subject to change without notice.
ETAsys.com
ETA-SEQ6
Sequencer Controller
Front Panel Description
6
6
2
3
6
6
4
5
1
1. System Activation Switch - Press to activate the ON or OFF sequence.
2. System Activation Switch Security Cover - If you do not want to use the Front Panel Activation Switch, place the security cover over the switch and secure using the retainer screw.
3. Power LED - Illuminates Blue when 24VDC power is present.
4. System Status/Ready LED - Flashes Green during a sequence and will illuminate steadily when sequence is complete indicating the system is powered up. When the LED is Off, it indicates the system is in the Off mode.
5. Channel Output LED - Each of the 6 outputs have their own LED which illuminates Red when the specific channel / output is active.
6. Bracket Retainer Points - Each TSD includes two mounting brackets for securing the TSD to a
cabinet or wall. Remove screws and align the bracket with the panel hole before firmly tightening the screws.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 3 –
Specifications are subject to change without notice.
ETAsys.com
ETA-SEQ6
Sequencer Controller
Rear Panel Description
10
10
2
10
10
1
3
4
5
6
7
8
9
TSD Input/Output connections are removable for easy system wiring. The connectors have a 3.5mm
pitch between pins.
1. DC Power Input - Each TSD that requires DC power comes with a 2 position connector for an external 24VDC power supply (sold separately). Because of the TSD’s low power consumption, a
single external power supply may power more than one TSD. Please refer to the specifications on current requirements in milliamps to match with the appropriate power supply. Please observe
the polarity of the wiring to this connector. Note: It is acceptable to exceed the current
requirements of the TSD but NOT safe to use a power supply that is below the current requirement of the device. Use a power supply with a 500mA capacity (Atlas TSD-PS24V500MA).
2. Channel Output - There are 6 channel output control ports. Each output can be assigned to provide a 24VDC output or a Hard Switch Contact Closure (CC). See the Function Settings for Output
configuration below.
3. Remote Activation Momentary Switch Port - Remote System activation can be done several hundred feet away via a momentary contact closure type switch.
4. Remote Activation Hard Switch Contact Closure (CC) Port - Remote System activation can be done several hundred feet away via a Hard Contact closure type switch.
5. Remote Activation 5 - 24VDC Port - Remote System activation can be done several hundred feet away by applying 5 - 24VDC. Only a few milliamps of current is required.
6. Link Control Port - You can combine two ETA-SEQ6 units together to make a 12 step sequence system. Note: Pay special attention to the Input and Output terminals. Connect the Output from
unit 1 (Master) to the Input of unit 2 (Slave). Connect the Output from unit 2 (Slave) to the Input of unit 1 (Master). Pay close attention to this or the Link Out will not work. See the Function Settings for the Master/Slave configuration below.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 4 –
Specifications are subject to change without notice.
ETAsys.com
ETA-SEQ6
Sequencer Controller
7. EPD “Emergency Power Down” Port - When an urgent system shut down is required, short the two pins together and the sequence portion will be bypassed and turn Off all outputs at the same time. This EPD feature is commonly used with fire control systems.
8. Delay Pot for Sequence 1 Output - The time between Sequence 1 Output and Sequence 2 Output can be set by rotating the pot following the indicators on the panel. In X1 mode the delay time adjustment is from 1 second to 60 seconds. In X10 mode the delay time adjustment is from
10 seconds to 360 seconds, or 6 minutes. See the Function Settings below for Sequence 1 Output
X1 or X10 configuration.
9. Delay Pot for Sequences 2-6 - The time between Sequence 2 Output and Sequence 6 Output can be set by rotating the pot following the indicators on the panel. Whatever the time is set to will be the time between Sequenced outputs.
10.Cable Management Retainer Points - Use the rear panel screws for connecting the included cable retainers. Each TSD comes with two cable retainers for simplified cable management.
Dip Switch Function Identification
SWITCH FUNCTIONS
Switch Position
•
•
•
DIP SW # 1-6 - Channel Output Assignment - Each output can be assigned to deliver a Hard Switch Contact Closure (CC) or +24VDC output when activated by the Sequence for Output Channels 1-6.
DIP SW # 7 - Link Assignment Configuration - This switch determines if the unit is to be a Master or a Slave unit. The Master unit is always the first in line of the sequence.
DIP SW # 8 - Sequence Output 1 Time Delay - In the X1 setting the adjustable time delay setting is from 1s to 60s and in the x10 position the time delay setting is from 10s to 360s, or 6 minutes.
Mounting
There are three ways to securely mount this TSD:
1. Velcro™ - Each unit includes industrial-grade Velcro™ with adhesive backing to adhere to any
flat surface.
2. Brackets - Each unit includes two mounting brackets to secure to a cabinet or wall.
3. Rack Mount Panel - The optional TSD-RMK rack mount panel supports up to four TSDs in a
1RU space.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 5 –
Specifications are subject to change without notice.
ETAsys.com
ETA-SEQ6
Sequencer Controller
Specifications
Description
Sequence Controller
Chassis Color
Chassis Material
Black
Aluminum
Outputs
Type
Connection
Qty 6, Sequenced Channel Output, Selectable 24VDC or CC
Removable 3 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, Link Input/Output
Removable 3 Position Captive Screw 3.5mm Spacing
Sequence Activation Controls
Type
Qty 1, Momentary Switch Front Panel
Type
Connection
Qty 1, Momentary Switch Port
Removable 2 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, Hard Switch Contact Closure (CC) Port
Removable 2 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, DC Voltage Port
Removable 2 Position Captive Screw 3.5mm Spacing
Type
Connection
Qty 1, Emergency Power Down (EPD)
Removable 2 Position Captive Screw 3.5mm Spacing
Controls
Dip Switch Function
• Output 1-6, Assign 24VDC or Contact Closure (CC)
• Link Assignment
• Sequence Output 1 Time Setting
Indicators
Sequence Status
Output Sequence Status
Power
Green, Qty 1
Red, Qty 6
Blue
Mounting
Velcro™
Brackets
TSD-RMK
Cable Retainer
Industrial-Grade, Included
Qty 2, Included
Optional 1 RU Rack Mount Panel (Supports 4 TSD Units)
Qty 2, Included
Power Requirements
Voltage
Power Consumption Current Power Consumption VA Watts
24VDC, 500mA
100mA
2.4W
Dimensions
H 1.5" (39mm) x W 4" (101mm) x D 2.75" (70mm)
Weight
6oz, .165kg
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 6 –
Specifications are subject to change without notice.
ETAsys.com
ETA-SEQ6
Sequencer Controller
Accessories
TSD 24VDC Power Supplies
TSD-RMK 1 RU Rack Panel
Safety and Certifications
External Power Supply
cUL, CE, RoHS, TUV
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 7 –
Specifications are subject to change without notice.
ETAsys.com
ETA-SEQ6
Sequencer Controller
Limited Warranty
All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or
commercial purchaser to be free from defects in material and workmanship and to be in compliance
with our published specifications, if any. This warranty shall extend from the date of purchase for
a period of one year. Additionally, fuses and lamps carry no warranty. ETA Systems will solely at
its discretion, replace at no charge or repair free of charge defective parts or products when the
product has been applied and used in accordance with our published operation and installation
instructions. We will not be responsible for defects caused by improper storage, misuse (including
failure to provide reasonable and necessary maintenance), accident, abnormal atmospheres, water
immersion, lightning discharge, or malfunctions when products have been modified or operated in
excess of rated power, altered, serviced or installed in other than a workmanlike manner. The original
sales invoice should be retained as evidence of purchase under the terms of this warranty. All
warranty returns must comply with our returns policy set forth below. When products returned to ETA
Systems do not qualify for repair or replacement under our warranty, repairs may be performed at
prevailing costs for material and labor unless there is included with the returned product(s) a written
request for an estimate of repair costs before any non-warranty work is performed. In the event of
replacement or upon completion of repairs, return shipment will be made with the transportation
charges collect.
EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL
DAMAGES FOR PERSONAL INJURY, ETA SYSTEMS SHALL NOT BE LIABLE IN TORT OR CONTRACT
FOR ANY DIRECT, CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE
INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS. THE ABOVE WARRANTY IS IN LIEU OF
ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE.
ETA Systems does not assume, nor does it authorize any other person to assume or extend on its
behalf, any other warranty, obligation, or liability. This warranty gives you specific legal rights and
you may have other rights which vary from state to state.
Service
Should your ETA-SEQ6 require service, please contact the ETA Systems
warranty department at 1-877-689-8055, ext. 277 to obtain an RA number.
ETA Systems Tech Support can be reached at 1-800-321-6699.
Visit our web site at www.ETAsys.com to see other ETA Systems products.
©2011 ETA Systems. All rights reserved. All other trademarks are the property of their respective owners. ETA004149 RevA 8/11
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 8 –
Specifications are subject to change without notice.
ETAsys.com